This document appears to be a bid sheet for a federal contract opportunity related to lighting supplies for Building 20 at the Defense Supply Center Columbus (DSCC) in Columbus, OH. The bid sheet lists various lighting products, their salient characteristics, quantities, and unit pricing. The related federal contract opportunity is Solicitation Number SP4702-24-Q-0030, issued by the Defense Logistics Agency (DLA), for the CSC-24911 project to provide lighting supplies for Building 20. The bid sheet includes items such as 2G11 PLL lamps, 3ft and 4ft T8 ballast bypass retrofit lamps, 6" and 8" LED can fixtures, and emergency backup ballasts. All items must support multiple voltage ranges from 120-277V.

View the file

Other files

File Type Posted
Solicitation Questions.pdf PDF
SF30-Amendment 001.pdf PDF
SP4702-24-Q-0030.pdf PDF
Scope of work.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASE YEAR

BID SHEET

PROJECT NO. CSC-24911 DRAWING NO. N/A DATE: 7/3/24

PROJECT TITLE: Lighting Supplies for Building 20

ARCHITECT/ENGINEER: Joseph May ESTIMATOR:

PRELIMINARY DESIGN FINAL DESIGN OTHER

ITEMQUANTITYMATERIALLABOREQUIP COSTTOTAL COST
NO. OF UNITSUNIT OF MEASUREPER UNITTOTALUNIT MANHOURTOTAL MANHOURSRATE PER HOURTOTALUNIT RATETOTAL
2G11 PLL lamp5392EA
3ft T8 Ballast Bypass Retro739EA
4ft T8 Ballast Bypass Retro2312EA
6" Can 5000K287EA
8" Can 5000K277EA
8" Can 4000K1263EA
Emergency Back Up Ballast for 4ft T8 retrofit Lamps as required185EA

SUBTOTAL $0.00

TOTAL $0.00

Salient Characteristics:

Material DescriptionColorLumensRetrofitBase TypeLength/WattageVoltageCRIL70OutputOutputEmergency
TypeDiameterVoltageWattageOperation Time
2G11 PLL Lamp4000K2800N/A2G1121.8 in23120 - 277V82100000N/AN/AN/A
3 ft T8 Ballast Bypass Retrofit Lamp4000K1440Type BT836 in11.5120 - 277V8354000N/AN/AN/A
4 ft T8 Ballast Bypass Retrofit Lamp4000K2200Type BT848 in17120 - 277V8254000N/AN/AN/A
6" CAN 5000K Fixture5000K1150N/ACAN6 in14120 - 277V9050000N/AN/AN/A
8" CAN 5000K Fixture5000K1800N/ACAN8 in20120 - 277V9050000N/AN/AN/A
8" CAN 4000K Fixture4000K1800N/ACAN8 in21120 - 277V9050000N/AN/AN/A
Emergency Backup Ballast for 4 ft T84000KN/AN/AN/AN/AN/A120 - 277VN/AN/A40-100 VDC1090 minutes
Retrofit Lamps as required
*NOTE: All items must support multiple voltages from 120-277 V