BID SHEET.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- CSC-24911 Building 20 Lighting Supplies
- Solicitation number
- SP4702-24-Q-0030
- Issued by
-
Defense Logistics Agency
About this file
This document appears to be a bid sheet for a federal contract opportunity related to lighting supplies for Building 20 at the Defense Supply Center Columbus (DSCC) in Columbus, OH. The bid sheet lists various lighting products, their salient characteristics, quantities, and unit pricing. The related federal contract opportunity is Solicitation Number SP4702-24-Q-0030, issued by the Defense Logistics Agency (DLA), for the CSC-24911 project to provide lighting supplies for Building 20. The bid sheet includes items such as 2G11 PLL lamps, 3ft and 4ft T8 ballast bypass retrofit lamps, 6" and 8" LED can fixtures, and emergency backup ballasts. All items must support multiple voltage ranges from 120-277V.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Questions.pdf | ||
| SF30-Amendment 001.pdf | ||
| SP4702-24-Q-0030.pdf | ||
| Scope of work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE YEAR
BID SHEET
PROJECT NO. CSC-24911 DRAWING NO. N/A DATE: 7/3/24
PROJECT TITLE: Lighting Supplies for Building 20
ARCHITECT/ENGINEER: Joseph May ESTIMATOR:
PRELIMINARY DESIGN FINAL DESIGN OTHER
| ITEM | QUANTITY | MATERIAL | LABOR | EQUIP COST | TOTAL COST | ||||||
| NO. OF UNITS | UNIT OF MEASURE | PER UNIT | TOTAL | UNIT MANHOUR | TOTAL MANHOURS | RATE PER HOUR | TOTAL | UNIT RATE | TOTAL |
| 2G11 PLL lamp | 5392 | EA |
| 3ft T8 Ballast Bypass Retro | 739 | EA |
| 4ft T8 Ballast Bypass Retro | 2312 | EA |
| 6" Can 5000K | 287 | EA |
| 8" Can 5000K | 277 | EA |
| 8" Can 4000K | 1263 | EA |
| Emergency Back Up Ballast for 4ft T8 retrofit Lamps as required | 185 | EA |
SUBTOTAL $0.00
TOTAL $0.00
Salient Characteristics:
| Material Description | Color | Lumens | Retrofit | Base Type | Length/ | Wattage | Voltage | CRI | L70 | Output | Output | Emergency |
| Type | Diameter | Voltage | Wattage | Operation Time | ||||||||
| 2G11 PLL Lamp | 4000K | 2800 | N/A | 2G11 | 21.8 in | 23 | 120 - 277V | 82 | 100000 | N/A | N/A | N/A |
| 3 ft T8 Ballast Bypass Retrofit Lamp | 4000K | 1440 | Type B | T8 | 36 in | 11.5 | 120 - 277V | 83 | 54000 | N/A | N/A | N/A |
| 4 ft T8 Ballast Bypass Retrofit Lamp | 4000K | 2200 | Type B | T8 | 48 in | 17 | 120 - 277V | 82 | 54000 | N/A | N/A | N/A |
| 6" CAN 5000K Fixture | 5000K | 1150 | N/A | CAN | 6 in | 14 | 120 - 277V | 90 | 50000 | N/A | N/A | N/A |
| 8" CAN 5000K Fixture | 5000K | 1800 | N/A | CAN | 8 in | 20 | 120 - 277V | 90 | 50000 | N/A | N/A | N/A |
| 8" CAN 4000K Fixture | 4000K | 1800 | N/A | CAN | 8 in | 21 | 120 - 277V | 90 | 50000 | N/A | N/A | N/A |
| Emergency Backup Ballast for 4 ft T8 | 4000K | N/A | N/A | N/A | N/A | N/A | 120 - 277V | N/A | N/A | 40-100 VDC | 10 | 90 minutes |
| Retrofit Lamps as required | ||||||||||||
| *NOTE: All items must support multiple voltages from 120-277 V |