Schriever B-400 09.09.10 - RA101.pdf

PDF 156 KB Posted

Attached to
Fall Protection Services Federal contract opportunity
Solicitation number
FA255022Q0022
Issued by
Department of the Air Force Space Command

View the file

Other files for this federal contract opportunity

Other files attached to Fall Protection Services, newest first.
File Type Posted
SCA Wage Determination Rev 21 2015-5417.pdf PDF
SCA Wage Determination 2015-5417 Rev 20 15 Mar 22.pdf PDF
Combined Synopsis-Solicitation - Fall Protection (1).docx DOCX document
Fall Protection Certification PWS 6 Jun 22.docx DOCX document
Schriever B-401 09.09.10 - RA101.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOF ANCHOR PLAN

D R A W I N G N O :

P R

O J

E C

T

N

A M

E

P R O J E C T # :

D R A W N B Y :

C H E C K E D B Y :

D R A W I N G T I T L E :

NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS

BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS

NO LONGER VALID.

S C A L E :

PLOT DATE :

S

O U

T H

W

E S T

S U

IT

E

S A

L T

L A

K E

C

IT

Y U

T A

H

P R

O J

E C

T

O

W N

E R

RA1.01

ROOF ANCHOR

PLAN

06.15.10

TM

KW

1" = 20'-0"

S C

H R

IE

V

E R

A F

B

B U

IL

D

IN

G

ROOF ANCHOR SYMBOL LEGEND

1 RESTRAINT CABLE FOR HORIZONTAL TRAVEL

NOTE:

WORKERS MUST USE A SELF-RETRACTING

LANYARD RATED FOR 900 lbs MAXIMUM

ARREST FORCE.

NOTE:

DO NOT ATTACH LANYARD DIRECTLY TO

CABLE OR ANCHOR. LANYARD TO BE

ATTACHED TO SHUTTLE ONLY.

NOTE:

THIS SYSTEM IS RATED FOR THE USE OF

TWO SIMULTANEOUS USERS ONLY.

THIS ENGINEER'S SEAL INDICATES ONLY THAT THE

STRUCTURAL COMPONENTS SUPPLIED BY ROOFTOP

ANCHOR, INC:

A) WILL RESIST THE LOADS INDICATED ON THIS

DRAWING WHEN ANALYZED BY CONVENTIONAL

ENGINEERING TECHNIQUES

-OR-

B) HAVE BEEN LAB TESTED FOR THE LOADS INDICATED.

INSPECTION

1. ROOFTOP ANCHOR EQUIPMENT SHALL NOT BE LOAD TESTED

WITHOUT PRIOR CONSENT FROM ROOFTOP ANCHOR, INC.

2. ANCHORAGES INSTALLED USING EPOXY ADHESIVE ANCHORS

ARE AUTOMATICALLY FIELD TESTED AT THE TIME OF

INSTALLATION IN ACCORDANCE WITH ROOFTOP ANCHOR'S

RECOMMENDED INSTALLATION AND TEST PROCEDURES.

3. ALL ROOFTOP ANCHOR, INC. PRODUCTS MUST BE INSPECTED

ANNUALLY BY CERTIFIED AND COMPETENT ROOFTOP

ANCHOR INSPECTOR IN ACCORDANCE WITH ANSI AND OSHA

STANDARDS AND REGULATIONS.

4. EPOXY ADHESIVE FASTENED ANCHOR MUST BE TESTED AND

RE-CERTIFIED AT INTERVALS NOT TO EXCEED FIVE YEARS. A

RECORD OF THE RE-CERTIFICATION SHOULD BE KEPT IN THE

BUILDING'S LOGBOOK.

5. ANY ANCHORS OR MATERIALS THAT APPEAR TO BE DAMAGED

AND DETERIORATED SHOULD NOT BE USED UNTIL THEY ARE

INSPECTED AND REPLACED UNDER SUPERVISION OF A

ROOFTOP ANCHOR ENGINEER.

6. YIELDING OF THE EQUIPMENT AND/OR SUPPORTING

STRUCTURE MAY OCCUR IN THE EVENT OF A FALL ARREST

INCIDENT. WHEN THE EQUIPMENT HAS BEEN IMPACTED BY

FALL ARREST LOADING, A THOROUGH INSPECTION OF

ROOFTOP ANCHOR EQUIPMENT AND THE SUPPORTING

STRUCTURE IS TO BE CONDUCTED, AND ANY DAMAGED

COMPONENT MUST BE REPAIRED OR REPLACED UNDER THE

DIRECTION OF A ROOFTOP ANCHOR ENGINEER.

7. DO NOT ATTACH OR CONNECT ANY LIGHTNING PROTECTION

DEVICES OR CONNECTIONS TO THIS SYSTEM. IT IS NOT AN

ACCEPTABLE GROUND.

USAGE

1. WORKERS ON A THE ROOF MUST BE PROPERLY ATTACHED

TO THE FALL PROTECTION EQUIPMENT WHEN WORKING NEAR

AN UNPROTECTED ROOF EDGE WITH A PARAPET LESS THAN

42" IN HEIGHT.

2. DO NOT ATTACH ANY TRANSPORTABLE FALL ARREST

EQUIPMENT SUCH AS OUTRIGGER BEAMS, PARAPET CLAMPS

OR HOOKS TO ANY COMPONENT ASSOCIATED WITH THE

HORIZONTAL CABLE SYSTEM.

3. WORKERS MUST USE AN ANSI APPROVED FULL BODY

HARNESS IN CONJUNCTION WITH A SELF-RETRACTING

LANYARD (DBI-SALA MODEL #3103207 RECOMMENDED OR

EQUIVALENT). WORKERS MUST BE PROPERLY TRAINED IN

THE USE OF THIS PPE.

4. ANYONE WHO USES ROOFTOP FALL PROTECTION SYSTEMS

SHOULD BE TRAINED BY A COMPETENT PERSON ON THE

CORRECT USAGE AND PRACTICES OF THE EQUIPMENT. ALL

USERS SHOULD HAVE A THOROUGH UNDERSTANDING OF ALL

APPLICABLE OSHA AND ANSI GUIDELINES TO INSURE A SAFE

WORK ENVIRONMENT.

5. THE INSTALLATION OF HORIZONTAL LIFELINES, STATIC LINES

AND/OR DOGLINES BETWEEN ANCHORS IS EXPRESSLY

PROHIBITED WITHOUT THE PRIOR WRITTEN AUTHORIZATION

FROM ROOFTOP ANCHOR, INC

6. THIS DRAWING MUST BE READ AND USED IN CONJUNCTION

WITH THE OPERATING INSTRUCTIONS DESCRIBED IN THE LOG

BOOK SUPPLIED BY ROOFTOP ANCHOR.

7. THIS SYSTEM MUST NOT BE USED IN CONJUNCTION WITH ANY

SUSPENDED ACTIVITIES; I.E., WINDOW CLEANING, GLASS

REPLACEMENT, ETC. THE HORIZONTAL LIFELINE SYSTEM IS

DESIGNED FOR TRAVEL RESTRAINT ONLY, NOT FALL ARREST.

DESIGN

1. GENERAL CONTRACTOR/ARCHITECT/CLIENT IS TO VERIFY

THAT THE LOCATION OF THE EQUIPMENT SUPPLIED BY

ROOFTOP ANCHOR DOES NOT CONFLICT WITH DOORWAYS,

ROOF DRAINS, MECHANICAL UNITS, ETC.

2. THE PORTIONS OF THE BUILDING STRUCTURE THAT SUPPORT

ROOFTOP ANCHOR EQUIPMENT HAVE NOT BEEN VERIFIED BY,

NOR ARE THE RESPONSIBILITY OF FARR DESIGNS BUT SHALL

BE VERIFIED BY THE PROJECT STRUCTURAL

ENGINEER/ARCHITECT FOR THE RESULTING FORCES AND

MOVEMENTS DUE TO THE LOADS SHOWN ON ROOFTOP

ANCHOR DRAWINGS. THE LOADS SHOWN ARE UNFACTORED

WORKING LOADS UNLESS OTHERWISE NOTED.

3. ROOFTOP ANCHOR, INC., NEEDS TO BE NOTIFIED OF ANY OR

ALL CHANGES THAT ARE MADE TO THIS DRAWING OR

ANCHOR SYSTEM.

4. THE CABLE STANCHIONS HAVE BEEN TESTED TO ENSURE

THAT THEY CAN WITHSTAND AN ULTIMATE LOAD OF 2640 LBS.

5. THE WORKING LOAD OF THE HORIZONTAL LIFE LINE SYSTEM

IS 660 LBS.

6. EQUIPMENT LAYOUT AND SAFETY SYSTEM HAVE NOT BEEN

VERIFIED BY, NOR ARE THE RESPONSIBILITY OF FARR

DESIGNS, BUT SHALL BE PART OF A SAFETY SYSTEM

PREPARED IN ACCORDANCE WITH ALL FEDERAL OSHA

REQUIREMENTS.