ROOF ANCHOR PLAN
D R A W I N G N O :
P R
O J
E C
T
N
A M
E
P R O J E C T # :
D R A W N B Y :
C H E C K E D B Y :
D R A W I N G T I T L E :
NOTE: IF THIS DRAWING IS NOT 36" x 24", IT HAS
BEEN REVISED FROM ITS ORIGINAL SIZE. SCALE IS
NO LONGER VALID.
S C A L E :
PLOT DATE :
S
O U
T H
W
E S T
S U
IT
E
S A
L T
L A
K E
C
IT
Y U
T A
H
P R
O J
E C
T
O
W N
E R
RA1.01
ROOF ANCHOR
PLAN
06.15.10
TM
KW
1" = 20'-0"
S C
H R
IE
V
E R
A F
B
B U
IL
D
IN
G
ROOF ANCHOR SYMBOL LEGEND
1 RESTRAINT CABLE FOR HORIZONTAL TRAVEL
NOTE:
WORKERS MUST USE A SELF-RETRACTING
LANYARD RATED FOR 900 lbs MAXIMUM
ARREST FORCE.
NOTE:
DO NOT ATTACH LANYARD DIRECTLY TO
CABLE OR ANCHOR. LANYARD TO BE
ATTACHED TO SHUTTLE ONLY.
NOTE:
THIS SYSTEM IS RATED FOR THE USE OF
TWO SIMULTANEOUS USERS ONLY.
THIS ENGINEER'S SEAL INDICATES ONLY THAT THE
STRUCTURAL COMPONENTS SUPPLIED BY ROOFTOP
ANCHOR, INC:
A) WILL RESIST THE LOADS INDICATED ON THIS
DRAWING WHEN ANALYZED BY CONVENTIONAL
ENGINEERING TECHNIQUES
-OR-
B) HAVE BEEN LAB TESTED FOR THE LOADS INDICATED.
INSPECTION
1. ROOFTOP ANCHOR EQUIPMENT SHALL NOT BE LOAD TESTED
WITHOUT PRIOR CONSENT FROM ROOFTOP ANCHOR, INC.
2. ANCHORAGES INSTALLED USING EPOXY ADHESIVE ANCHORS
ARE AUTOMATICALLY FIELD TESTED AT THE TIME OF
INSTALLATION IN ACCORDANCE WITH ROOFTOP ANCHOR'S
RECOMMENDED INSTALLATION AND TEST PROCEDURES.
3. ALL ROOFTOP ANCHOR, INC. PRODUCTS MUST BE INSPECTED
ANNUALLY BY CERTIFIED AND COMPETENT ROOFTOP
ANCHOR INSPECTOR IN ACCORDANCE WITH ANSI AND OSHA
STANDARDS AND REGULATIONS.
4. EPOXY ADHESIVE FASTENED ANCHOR MUST BE TESTED AND
RE-CERTIFIED AT INTERVALS NOT TO EXCEED FIVE YEARS. A
RECORD OF THE RE-CERTIFICATION SHOULD BE KEPT IN THE
BUILDING'S LOGBOOK.
5. ANY ANCHORS OR MATERIALS THAT APPEAR TO BE DAMAGED
AND DETERIORATED SHOULD NOT BE USED UNTIL THEY ARE
INSPECTED AND REPLACED UNDER SUPERVISION OF A
ROOFTOP ANCHOR ENGINEER.
6. YIELDING OF THE EQUIPMENT AND/OR SUPPORTING
STRUCTURE MAY OCCUR IN THE EVENT OF A FALL ARREST
INCIDENT. WHEN THE EQUIPMENT HAS BEEN IMPACTED BY
FALL ARREST LOADING, A THOROUGH INSPECTION OF
ROOFTOP ANCHOR EQUIPMENT AND THE SUPPORTING
STRUCTURE IS TO BE CONDUCTED, AND ANY DAMAGED
COMPONENT MUST BE REPAIRED OR REPLACED UNDER THE
DIRECTION OF A ROOFTOP ANCHOR ENGINEER.
7. DO NOT ATTACH OR CONNECT ANY LIGHTNING PROTECTION
DEVICES OR CONNECTIONS TO THIS SYSTEM. IT IS NOT AN
ACCEPTABLE GROUND.
USAGE
1. WORKERS ON A THE ROOF MUST BE PROPERLY ATTACHED
TO THE FALL PROTECTION EQUIPMENT WHEN WORKING NEAR
AN UNPROTECTED ROOF EDGE WITH A PARAPET LESS THAN
42" IN HEIGHT.
2. DO NOT ATTACH ANY TRANSPORTABLE FALL ARREST
EQUIPMENT SUCH AS OUTRIGGER BEAMS, PARAPET CLAMPS
OR HOOKS TO ANY COMPONENT ASSOCIATED WITH THE
HORIZONTAL CABLE SYSTEM.
3. WORKERS MUST USE AN ANSI APPROVED FULL BODY
HARNESS IN CONJUNCTION WITH A SELF-RETRACTING
LANYARD (DBI-SALA MODEL #3103207 RECOMMENDED OR
EQUIVALENT). WORKERS MUST BE PROPERLY TRAINED IN
THE USE OF THIS PPE.
4. ANYONE WHO USES ROOFTOP FALL PROTECTION SYSTEMS
SHOULD BE TRAINED BY A COMPETENT PERSON ON THE
CORRECT USAGE AND PRACTICES OF THE EQUIPMENT. ALL
USERS SHOULD HAVE A THOROUGH UNDERSTANDING OF ALL
APPLICABLE OSHA AND ANSI GUIDELINES TO INSURE A SAFE
WORK ENVIRONMENT.
5. THE INSTALLATION OF HORIZONTAL LIFELINES, STATIC LINES
AND/OR DOGLINES BETWEEN ANCHORS IS EXPRESSLY
PROHIBITED WITHOUT THE PRIOR WRITTEN AUTHORIZATION
FROM ROOFTOP ANCHOR, INC
6. THIS DRAWING MUST BE READ AND USED IN CONJUNCTION
WITH THE OPERATING INSTRUCTIONS DESCRIBED IN THE LOG
BOOK SUPPLIED BY ROOFTOP ANCHOR.
7. THIS SYSTEM MUST NOT BE USED IN CONJUNCTION WITH ANY
SUSPENDED ACTIVITIES; I.E., WINDOW CLEANING, GLASS
REPLACEMENT, ETC. THE HORIZONTAL LIFELINE SYSTEM IS
DESIGNED FOR TRAVEL RESTRAINT ONLY, NOT FALL ARREST.
DESIGN
1. GENERAL CONTRACTOR/ARCHITECT/CLIENT IS TO VERIFY
THAT THE LOCATION OF THE EQUIPMENT SUPPLIED BY
ROOFTOP ANCHOR DOES NOT CONFLICT WITH DOORWAYS,
ROOF DRAINS, MECHANICAL UNITS, ETC.
2. THE PORTIONS OF THE BUILDING STRUCTURE THAT SUPPORT
ROOFTOP ANCHOR EQUIPMENT HAVE NOT BEEN VERIFIED BY,
NOR ARE THE RESPONSIBILITY OF FARR DESIGNS BUT SHALL
BE VERIFIED BY THE PROJECT STRUCTURAL
ENGINEER/ARCHITECT FOR THE RESULTING FORCES AND
MOVEMENTS DUE TO THE LOADS SHOWN ON ROOFTOP
ANCHOR DRAWINGS. THE LOADS SHOWN ARE UNFACTORED
WORKING LOADS UNLESS OTHERWISE NOTED.
3. ROOFTOP ANCHOR, INC., NEEDS TO BE NOTIFIED OF ANY OR
ALL CHANGES THAT ARE MADE TO THIS DRAWING OR
ANCHOR SYSTEM.
4. THE CABLE STANCHIONS HAVE BEEN TESTED TO ENSURE
THAT THEY CAN WITHSTAND AN ULTIMATE LOAD OF 2640 LBS.
5. THE WORKING LOAD OF THE HORIZONTAL LIFE LINE SYSTEM
IS 660 LBS.
6. EQUIPMENT LAYOUT AND SAFETY SYSTEM HAVE NOT BEEN
VERIFIED BY, NOR ARE THE RESPONSIBILITY OF FARR
DESIGNS, BUT SHALL BE PART OF A SAFETY SYSTEM
PREPARED IN ACCORDANCE WITH ALL FEDERAL OSHA
REQUIREMENTS.