This document is a schedule of pricing for a federal contract opportunity to replace the gas monitoring systems in the chiller and boiler plants at the Carl Vinson VA Medical Center in Dublin, Georgia. The contract opportunity is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under Solicitation Number 36C24724Q0680. The scope of work includes installing new refrigerant, carbon monoxide, and combustible gas sensors and monitoring systems, with commissioning assistance. The work must be completed within 60 calendar days after award. Offers are due by 5:00 PM EST on May 30, 2024. Award will be made based on the lowest priced, technically acceptable offer, considering technical capability and past performance. A site visit is scheduled for May 16, 2024, and requests for information must be submitted by May 22, 2024.

View the file

Other files

File Type Posted
36C24724Q0680 0001.docx DOCX document
Site Visit Map.pdf PDF
STATEMENT OF WORK.pdf PDF
Wage Determination No 2015-4505 Rev 27.docx DOCX document
36C24724Q0680_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

?.## PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
1.00
EA
__________________
__________________

Install 1 Chill Guard Refrigerant monitoring system in the Chiller Plant. Install 4 CO gas sensing elements (sensors) in the Chiller Plant. Install 2 Combustible Gas sensing elements (sensors) in the Chiller Plant. Install 1 Gas Guard Gas monitoring system in the Steam Boiler Plant. Install 4 CO gas sensing elements (sensors) in the Steam Boiler Plant. Install 4 Combustible Gas sensing elements (sensors) in the Steam Boiler Plant. Commissioning Assistance for above installed equipment.

LOCAL STOCK NUMBER: LABOR

1.00
EA
__________________
__________________

Install 1 Chill Guard Refrigerant monitoring system in the Chiller Plant. Install 4 CO gas sensing elements (sensors) in the Chiller Plant. Install 2 Combustible Gas sensing elements (sensors) in the Chiller Plant. Install 1 Gas Guard Gas monitoring system in the Steam Boiler Plant. Install 4 CO gas sensing elements (sensors) in the Steam Boiler Plant. Install 4 Combustible Gas sensing elements (sensors) in the Steam Boiler Plant. Material needed for line item 1

LOCAL STOCK NUMBER: MATERIAL

GRAND TOTAL