SATPC0042688 Tab 04 4 SOW..pdf

PDF 168 KB Posted

Attached to
High Vacuum Gas Sorption Analyzer Purchase
Solicitation number
80NSSC26943401Q
Issued by

About this file

This is a Statement of Work for the procurement of laboratory analytical equipment and related services for NASA Glenn Research Center in Cleveland, Ohio.

The purchase requires one Autosorb 6100 Three Station High Vacuum Gas Sorption Analyzer, a three-station physisorption analyzer designed to measure specific surface area and pore size distributions from 0.35 to 500 nanometers, featuring 3 micropore analysis stations with multiple transducers, 6 degassing stations, TruZone active coolant level control, precise manifold temperature control, and compatibility with various non-corrosive gases. Supporting items include one AS6X00 Physisorption Kit containing dewars, coolant level sensors, and analysis cells; one AS6X00 Physisorption Cell Handling Kit with cell handling accessories; six Type A Long Cells (9 mm, no bulb); one bottle each of Surface Area Reference Material SARM 2012 (microporous zeolite with 750 m²/g nominal BET surface area) and SARM 2005 (aluminum oxide with 100 m²/g nominal surface area) for system validation. Additionally, the statement of work includes Anton Paar Installation services performed by qualified personnel according to manufacturer specifications using certified and calibrated equipment, and Anton Paar Training services providing end-user training on instrument operation, maintenance, and cleaning with training certificates for all participants. Performance will be completed within 4-6 weeks after receipt of order at NASA Glenn Research Center, 21000 Brookpark Road, Cleveland, Ohio 44135-3127.

View the file

Other files

File Type Posted
SATPC0042688 Tab 07 Capability Statement.pdf PDF
SATPC0042688 Tab 06 RDSS..pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements

The information listed below is required to complete this purchase.

2. Characteristics, Scope, and Specs

PART NO. DESCRIPTION QTY.

403050|

9027898060

Autosorb 6100 Three Station

HIGH VACUUM GAS SORPTION ANALYZER

Three station physisorption analyzer designed for measurements of specific surface area and pore size distributions from 0.35 to 500 nm.

Key Features:

- 3 micropore analysis stations with 1550, 10, and 1 Torr transducers

- 6 degassing stations for all-in-one sample preparation and analysis

- TruZone active coolant level control for high sensitivity analyses

- Precise manifold temperature control (+/- 0.05 °C) from 35 to 50 °C

- DoseWizard system for easy and flexible measurement definition

- PowderProtect for precise evacuation without powder elutriation

- Kaomi for Autosorb software for instrument control and data reduction

- Compatible with He, N2, Ar, Kr, CO2, CH4 and other non-corrosive gases

- Type A glassware compatible

421979|

9027894560

AS6X00, PHYSISORPTION KIT

Accessory kit with necessary items to perform physisorption measurements on

Autosorb 6X00 instruments.

Kit includes:

- Long life 3 L Dewar allowing 90 hours of continuous analysis with LN2

- Coolant level sensor for TruZone active coolant level control

- Safety cover, analysis dewar lid, and cryogen measuring stick

- 2 L cold trap dewar and heating mantles for degassing

- Type A cells, p0 cell, and p0 collar

422230|

9027894560

AS6X00, PHYSISORPTION CELL HANDLING KIT

Accessory kit for handling physisorption cells. Kit includes type A cells, type A rods, a long stem cell funnel, stem cleaners, non-elutriating plugs, cell holder for balance, and sample cell caps.

193922|

7017905000

TYPE A LONG CELL, 9 mm NO BULB

Type A long cell with 9 mm stem and no bulb. Borosilicate Glass. Nominal

Dimensions: 9 mm OD (7 mm ID), cell length 312.5 mm, 1 cm3 capacity.

193445|

3822900000

SURFACE AREA REFERENCE MATERIAL, 2012

SARM 2012, microporous zeolite validates high vacuum gas sorption systems.

0.5 nm zeolite powder with 750 m2/g nominal BET surface area using nitrogen.

Analysis requires helium and nitrogen gas and liquid nitrogen. One bottle contains 10 aliquots (minimum 0.025 g per aliquot) of white powder.

193441

| 3822900000

SURFACE AREA REFERENCE MATERIAL, 2005

SARM 2005, Aluminum oxide used to validate physisorption systems. Certified value of Specific Surface Area of nominally 100 m2/g. Need Helium and

Nitrogen gas, and liquid nitrogen. Minimum 0.1 g. One bottle contains 13 g sample of white powder for 11 point BET.

P00697|

90279000

Anton Paar Installation

This service includes:

- The installation according to the manufacturer’s specifications

The installation will be carried out by qualified Anton Paar personnel, by using certified and calibrated equipment.

P01182|

90279000

Anton Paar Training

This service includes:

- End User Training on the use of the instrument, proper upkeep and cleaning

- Training Certificate for every participant

The training will be carried out by qualified Anton Paar personnel.

3. Place of Performance NASA Glenn Research Center 21000 Brookpark Rd Cleveland OH 44135-3127

4. Period of Performance

4-6 weeks ARO

File details come from the government source that posted it. Updated .