Attachment_11_086_-_H-1.1.pdf
PDF 1 MB Posted
- Solicitation number
- SAQMMA17R0041
About this file
SAQMMA17R0041 Attachment 11 086 - H-1.1
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PHASE:
DRAWING DATE:
REVISIONS:
NOTICE:
I.N.L
MANAGED BY:
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
MARZO 23/2017
CONTRACT DATE:CONTRACT NUMBER:
PURCHASE ORDER:
OBSERVATIONS:
CONTENIDO:
SHEET PLAN: SCALE:
CONTENTS:
LOCATION:
Ing. Alejandro Duran O.
SHEET: DESIGNED BY:
PROFFESIONAL CARD:
SIGNATURE:
DRAWING DATE:
2520204364 CND
COR:
A & E DESIGN FIRM:
PROJECT:
PROFFESION:
Ingeniero - Hidraulico
LEGEND:
PERFORM ARCHITECTURAL AND ENGINEERING
DESIGN SERVICES FOR THE CONSTRUCTION OF
A NEW WATER SUPPLY SEWAGE AND
ELECTRICAL UTILITIES FOR A COLOMBIAN
NATIONAL POLICE (CNP) COMPLEX LOCATED IN
CAUCASIA, COLOMBIA,
IN THE CEFOB/DIRAN AREA
1 2 3 4 5 6
E
D
C
B
A
H-1
H-1
INDICADAS
ESCALA:
SCALE: 1:300
H1
1:300
SUMINISTRO DE AGUA POTABLE
PLANTA GENERAL DE REDES
WATER SUPPLY SYSTEM
NETWORK GENERAL PLAN
INSPECTION PLUG PVC
SANITARY POINT
INSPECTION BOX
Ø4"
PIPE DIAMETER
RAIN WATER PIPE
B.AN. 1
B.ALL. 1
RAIN WATER DRAIN PIPE
SEWAGE DRAIN PIPE
DRAIN PVC
VENTILATION PIPE
PROJECTED DRAIN PIPE
COUPLING PVC 45°
YEE COUPLING PVC 45° PIPE TO BE REMOVED
(Tapón PVC Sanitario)
(Codo PVC 45°)
(Yee PVC 45°)
(Sifón PVC)
(Punto Sanitario)
(Tubería de drenaje proyectada)
(Tubería de ventilación)
(Bajante de Aguas Negras )
(Bajante Aguas Lluvias )
(Tubería Aguas LLuvias)
(Tubería a eliminar)
(Diámetro Tubería)
(Caja de inspección)
1. LAS DIMENSIONES ESTAN EXPRESADAS EN METROS EXCEPTO CUANDO SE
INDIQUE OTRA UNIDAD.
2. LOS DIAMETROS DE LAS TUBERIAS ESTAN EXPRESADOS EN PULGADAS Y
CORRESPONDEN A SU VALOR NOMINAL.
3. LAS TUBERÍAS DE SUMINISTRO DEBERÁN SER EN PVC-P RDE 21, EXCEPTO
CUANDO SE INDIQUE OTRO MATERIAL.
4. EL REGISTRO SE ENCUENTRA A UNA ALTURA DE 0.30 M. DESDE EL NIVEL DEL
PISO TERMINADO.
5. LAS TUBERÍAS DE CONEXIÓN A LOS APARATOS DEBEN SER CONSTRUIDAS
CON TUBERÍA GALVANIZADA..
1. THE DIMENSIONS ARE IN INCHES UNLESS WHEN OTHER UNIT ARE
INDICATED.
2. THE PIPE DIAMETERS ARE EXPRESSED IN INCHES AND IT IS NOMINAL
VALUE.
3. THE SUPPLY PIPES SHALL BE IN RDE 21 PVC-P, EXCEPT WHERE
INDICATED.
4. THE CUTOFF REGISTERS SHAL BE INSTALLED AT 0.30M HIGH FROM
THE FINISH FLOOR.
5. THE CONNECTION PIPES TO THE APPLIANCES SHALL BE IN
GALVANIZED PIPING
ESCALA:
SCALE: 1:50
H1
1:50
ALMACENAMIENTO AGUA POTABLE
DETALLE TANQUE DE
STORAGE TANK DETAIL
DRINKING WATER
86-CEFOP-DIRAN-H1.dwg
INSPECTION WELL
(Pozo de inspección)
ESCALA:
SCALE: 1:2
H1
1:2
ALMACENAMIENTO AGUA POTABLE
DETALLE BLOQUES DE ANCLAJE
WATER SUPPLY SYSTEM
ANCHORING BLOCK DETAIL
ESCALA:
SCALE: 1:10
H1
1:10
ALMACENAMIENTO AGUA POTABLE
DETALLE CIMENTACION TUBERIA
WATER SUPPLY SYSTEM
PIPING FOUNDATION DETAIL
File details come from the government source that posted it. Updated .