SAMPLE 4730 IRPOD 2.pdf

PDF 49 KB Posted

Attached to
FSC4730_BPA_RFI
Solicitation number
FSC4730_BPA_RFI
Issued by

About this file

This is an Individual Repair Part Ordering Data (IRPOD) document for a connector straight threaded 1/4 inch component manufactured by Parker-Hannifin Tube Fittings Division. The part is identified by National Stock Number 1H 4730-01-220-2024 X3 with manufacturer's part number 4-6-F5BU-SS(SPCLN), revision dated 03/02/2026, and technical contact 9N291106020053.

The document establishes comprehensive requirements for the procurement and delivery of this connector assembly. Key technical requirements include cleaning to MIL-STD-767 specifications as modified by AOR-767G-1, with detrimental material control requirements in Section 5 not applicable. The specification prohibits intentional addition or direct contact of mercury or mercury-containing compounds with the hardware. Manufacturing and process requirements mandate compliance with the identified military standards and applicable publications. Preparation for delivery requires marking and labeling per MIL-STD-129, including bar code marking suitable for hand scanning, manufacturer's CAGE code, and manufacturer reference/part number on intermediate and unit packs. Packaging shall comply with MIL-STD-2073-1 codes as specified in the contract. Contract data requirements include seller submittals prior to manufacture for approval of post cleaning test requirements, subassembly cleaning requirements, and subcontractor cleaning and testing requirements under AOR-767G-1. The document references applicable military standards MIL-STD-129, MIL-STD-767 (Revision G), and publication AOR-767G-1 for control of foreign materials.

View the file

Other files

File Type Posted
SAMPLE 4730 IRPOD.pdf PDF
FSC4730_BPA_RFI.pdf PDF
SAMPLE 4730 IRPOD 3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

03/02/2026

ITEM NAMENATIONAL STOCK NUMBER

DRAWING PREPARER/MANUFACTURER

REVISION

MANUFACTURER'S PART NO./DRAWING NO. RSP

ACTIVITY

1H 4730-01-220-2024 X3 CONN STR THD 1/4 IN 20250320151846

PARKER-HANNIFIN TUBE FITTINGS DIV 4-6-F5BU-SS(SPCLN) N

INDIVIDUAL REPAIR PART ORDERING DATA PAGE 1RPTR01A

9N291106020053

TECHNICAL CONTACT

1.0 SCOPE

THE DESIGNATION "(SPCLN)" AT THE END OF THE DWG NO./MFR'SPART NO. INDICATES THAT

THE PART IS CLEANED TO THE REQUIREMENTS OF MIL-STD-767 AS REQUIRED ELSEWHERE IN

THIS DOCUMENT. THE "(SPCLN)" DESIGNATION IS FOR NAVY IDENTIFICATION PURPOSESONLY

AND IS NOT PART OF THE MANUFACTURER'S PART NUMBER.

1.1 THIS IRPOD PROVIDES THE REQUIREMENTS FOR AN ASSEMBLY.

SPECIFIC REQUIREMENTS ARE IDENTIFIED IN THIS IRPOD AND BY

DRAWINGS AND SPECIFICATIONS CITED WITHIN THIS IRPOD.

2.0 LIST OF APPLICABLE DOCUMENTS

IF A SUPPLIER QUOTES TO A LATER REVISION OF THE DRAWING (OR CATALOG ITEM) THAN

SPECIFIED BELOW, SUBMITTAL OF QUOTE SHALL INCLUDE TWO (2) COPIES OF THE REVISED

DOCUMENT AND AN EVALUATION OF THE INTERCHANGEABILITY. THE FOLLOWING DOCUMENTS AND

CHANGE DATA ARE APPLICABLE TO THE EXTENT SPECIFIED IN THIS IRPOD, THE DRAWINGS, OR

OTHER DOCUMENTS INVOKED BY THIS IRPOD. CONTRACTING AGENCY APPROVAL IS REQUIRED TO

USE EARLIER SPECIFICATION VERSIONS THAN THOSE LISTED HEREIN, EXCEPT AS IDENTIFIED

BELOW. IF NO DOCUMENT VERSION IS LISTED, THEN ANY VERSION OF THE DOCUMENT MAY BE

USED.

RAW MATERIAL REQUIRED HEREIN MAY HAVE BEEN PROCESSED OR TESTED (FOR EXAMPLE, HEAT

TREATED OR ULTRASONICALLY TESTED) AS REQUIRED BY THE RAW MATERIAL SPECIFICATION

PRIOR TO RECEIPT OF THIS ORDER USING PREVIOUS VERSIONS OF PROCESSING OR TESTING

SPECIFICATIONS. THIS PROCESSING AND TESTING NEED NOT BE REPEATED IF:

1.IT COMPLIED WITH THE APPLICABLE REQUIREMENTS OF THE

PROCESSING/TESTING SPECIFICATION VERSIONS IN EFFECT AT THE TIME OF

THE ACTUAL PROCESSING OR TESTING AND;

2.ALL REQUIREMENTS OF THE RAW MATERIAL SPECIFICATION VERSION LISTED

HEREIN HAVE BEEN SATISFIED.

SECTION 6.0 IDENTIFIES SPECIAL REQUIREMENTS FOR SUBMITTAL OF THE PROCEDURES USED

FOR COMPLETED PROCESSING AND TESTING. ALL PROCESSING AND TESTING PERFORMED AFTER

RECEIPT OF THIS ORDER SHALL CONFORM TO THE PROCESSING/TESTING SPECIFICATION

VERSIONS LISTED HEREIN.

DOCUMENT NUMBER VERSION TITLE

MILITARY STANDARDS

+ MIL-STD-129 MARKING FOR SHIPMENT AND STORAGE

* MIL-STD-767 G CONTROL OF HARDWARE CLEANLINESS

PUBLICATIONS

* AOR-767G-1 ADDITIONAL ORDERING REQUIREMENTS FOR

MIL-STD-767G (CONTROL OF FOREIGN MATERIALS)

OTHERS

DRAWING PREPARER/MANUFACTURER

REVISION

MANUFACTURER'S PART NO./DRAWING NO. RSP

ACTIVITY

1H 4730-01-220-2024 X3 CONN STR THD 1/4 IN 20250320151846

PARKER-HANNIFIN TUBE FITTINGS DIV 4-6-F5BU-SS(SPCLN) N

INDIVIDUAL REPAIR PART ORDERING DATA PAGE 2RPTR01A

9N291106020053

TECHNICAL CONTACT

4302 PARKER-HANNIFIN CO

* DOCUMENTS IDENTIFIED BY THIS SYMBOL MAY BE OBTAINED

FROM CONTRACT ISSUING AGENCY.

+ LATER VERSIONS (IE: REVISIONS, AMENDMENTS, CHANGE NOTICES

AND/OR INTERIM CHANGES) OF DOCUMENTS IDENTIFIED BY THIS SYMBOL

MAY BE USED IN THE PERFORMANCE OF THE CONTRACT. WHICHEVER

VERSION IS USED MUST BE USED IN ITS ENTIRETY. THE LATER

VERSION MAY BE IDENTIFIED AS "MIL-DTL-" OR "MIL-PRF-" AS

APPLICABLE, WHICH IS EQUIVALENT TO "MIL-#-" (WHERE # IS AN

ALPHA CHARACTER).

3.0 TECHNICAL REQUIREMENTS

3.1 MATERIAL REQUIREMENTS

INTENTIONALLY LEFT BLANK

3.2 MANUFACTURING AND PROCESS REQUIREMENTS

CONN STR THD 1/4 IN 4-6-F5BU-SS(SPCLN)

CLEANLINESS REQUIREMENTS: THIS ITEM SHALL BE CLEANED IN ACCORDANCE WITH THE

REQUIREMENTS OF MIL-STD-767 AS MODIFIED BY AOR-767G-1; DETRIMENTAL MATERIAL

CONTROL REQUIREMENTS, SECTION 5, DO NOT APPLY. AOR-767G-1 IDENTIFIES SPECIFIC

CONDITIONAL SELLER SUBMITTALS AND THE CONDITIONS UNDER WHICH SUBMITTAL TO THE

PROCURING ACTIVITY FOR APPROVAL IS REQUIRED.

MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL NOT BE INTENTIONALLY ADDED OR COME

IN DIRECT CONTACT WITH HARDWARE OR SUPPLIES FURNISHED UNDER THIS CONTRACT.

NOTES 1,2,3,4 AND 5 NOT APPLICABLE

4.0 QUALITY ASSURANCE PROVISIONS

INTENTIONALLY LEFT BLANK

5.0 PREPARATION FOR DELIVERY

CONN STR THD 1/4 IN 4-6-F5BU-SS(SPCLN)

MARKING REQUIREMENTS:

MARKING AND LABELING SHALL BE IN ACCORDANCE WITH MIL-STD-129.

BAR CODE MARKING SUITABLE FOR HAND SCANNING IS REQUIRED.

IN ADDITION TO THE STANDARD MARKING REQUIREMENTS OF MIL-STD-129,

THE SELLER SHALL INCLUDE THE MANUFACTURER'S COMMERCIAL AND

GOVERNMENT ENTITY (CAGE) CODE AND THE MANUFACTURER'S REFERENCE/

PART NUMBER (MFR/PN) ON INTERMEDIATE AND UNIT PACKS.

PACKAGING AND PACKING REQUIREMENTS:PACKAGING CODES FOR MIL-STD-2073-1 SHALL BE AS

SPECIFIED ELSEWHERE IN THE CONTRACT.

6.0 CONTRACT DATA REQUIREMENTS

DRAWING PREPARER/MANUFACTURER

REVISION

MANUFACTURER'S PART NO./DRAWING NO. RSP

ACTIVITY

1H 4730-01-220-2024 X3 CONN STR THD 1/4 IN 20250320151846

PARKER-HANNIFIN TUBE FITTINGS DIV 4-6-F5BU-SS(SPCLN) N

INDIVIDUAL REPAIR PART ORDERING DATA PAGE 3RPTR01A

9N291106020053

TECHNICAL CONTACT

THE SELLER MUST PROVIDE THE CONTRACTING AGENCY WITH ALL OF THE

SUBMITTALS LISTED BELOW. SUBMITTALS WHICH ARE REQUIRED BY A

SPECIFICATION, BUT WHICH ARE NOT LISTED BELOW, NEED NOT BE

SUBMITTED. ONLY THOSE SUBMITTALS LISTED BELOW ARE REQUIRED.

HOWEVER, IF THE SELLER CONSIDERS A REQUIRED SUBMITTAL INAPPLICABLE

TO THIS PROCUREMENT, THE SELLER MUST SUBMIT A STATEMENT JUSTIFYING

THE EXCLUSION OF THE REQUIRED SUBMITTAL.

REQUESTS FOR APPROVAL OF PROCEDURES USED PRIOR TO RECEIPT OF THIS

ORDER SHALL IDENTIFY THE PROCESSING/TESTING SPECIFICATION VERSION

APPLICABLE AND STATE THAT THE PROCESSING AND/OR TESTING WAS

PERFORMED PRIOR TO RECEIPT OF THE ORDER. IF THE PROCEDURE THAT WAS

USED IS NOT COMPLETE, TEST REPORTS, HEAT TREATMENT RECORDS, OR

OTHER DOCUMENTATION SHALL BE SUBMITTED WITH THE PROCEDURES TO

SUBSTANTIATE THAT ALL SPECIFICATION REQUIREMENTS WERE MET.

@ SUBMITTAL REQUIREMENTS IDENTIFIED BY THIS SYMBOL ARE

CONDITIONAL AND ARE REQUIRED ONLY IF APPLICABLE TO THIS

PROCUREMENT.

6.1 PROCEDURES AND REPORTS

THE SELLER SHALL PROVIDE THE FOLLOWING PROCEDURE(S) AND REPORT(S) TO THE PROCURING

ACTIVITY. CONTRACTOR PROCEDURE SUBMITTALS REQUIRED BY MATERIAL AND PROCESS

SPECIFICATIONS NEED NOT BE RESUBMITTED FOR APPROVAL EACH TIME AN ORDER IS PLACED

FOR THE SAME IRPOD ITEM TO THE SAME VERSION (I.E., REVISION, AMENDMENT, CHANGE

NOTICE OR INTERIM CHANGE) OF THE SPECIFICATION OR STANDARD INVOKED. THE SELLER

NEED ONLY SUBMIT PROOF OF THE PRIOR APPROVAL FOR THAT ITEM AND SPECIFICATION

REVISION. ACCEPTABLE PROOF OF PRIOR APPROVAL WILL CONSIST OF A COORDINATED

PROCEDURE REVIEW SYSTEM (CPRS) APPROVAL LETTER. CPRS APPROVAL DOES NOT RELIEVE

THE SELLER OF THE RESPONSIBILITY TO COMPLY WITH ALL REQUIREMENTS IMPOSED ON ANY

CURRENT AND FUTURE PURCHASE ORDERS.

IF FIRST-TIER MANUFACTURER RETESTING OF MATERIAL IS NECESSARY, USE OF BUYER

APPROVED PROCEDURES APPLICABLE TO THE SAME VERSION OF THE SPECIFICATION OR

STANDARD INVOKED ON THE IRPOD IS ACCEPTABLE IN LIEU OF OBTAINING THE RAW MATERIAL

MANUFACTURER OR MATERIAL INSPECTION AND TEST PROCEDURES FOR APPROVAL.

WHERE ALTERNATIVE SPECIFICATIONS ARE SHOWN FOR A GIVEN ITEM, ONLY THE DATA FOR THE

SPECIFICATION USED IS REQUIRED. THE SELLER SHALL SPECIFY THE FOLLOWING ON

PROCEDURE(S)/REPORT(S) REQUIRING SUBMITTAL, AS APPLICABLE, IN ORDER THAT THE

PROCEDURE/REPORT CAN BE READILY REVIEWED AGAINST THE APPROPRIATE ACCEPTANCE

CRITERIA: SPECIFICATION AND REVISION, INCLUDING AMENDMENTS, NOTICES, ETC.,

APPLICABLE PARAGRAPH OF THE SPECIFICATION, THE NAME OF THE SUBMITTAL, THE MATERIAL

CONDITIONS (I.E., MATERIAL GRADE, CLASS, TYPE, SIZE, COMPOSITION, ETC.).

DRAWING PREPARER/MANUFACTURER

REVISION

MANUFACTURER'S PART NO./DRAWING NO. RSP

ACTIVITY

1H 4730-01-220-2024 X3 CONN STR THD 1/4 IN 20250320151846

PARKER-HANNIFIN TUBE FITTINGS DIV 4-6-F5BU-SS(SPCLN) N

INDIVIDUAL REPAIR PART ORDERING DATA PAGE 4RPTR01A

9N291106020053

TECHNICAL CONTACT

6.1.1 PRIOR TO MANUFACTURE, FOR APPROVAL:

CONN STR THD 1/4 IN 4-6-F5BU-SS(SPCLN)

6.1.1 PRIOR TO MANUFACTURE, FOR APPROVAL:

AOR-767G-1

@POST CLEANING TEST REQUIREMENTS

@SUBASSEMBLY CLEANING REQUIREMENTS

@SUBCONTRACTOR CLEANING AND TESTING REQUIREMENTS

6.2 OTHER CONTRACT DATA REQUIREMENTS

INTENTIONALLY LEFT BLANK

File details come from the government source that posted it. Updated .