S02 - SOW Attachment 3 - Sensitive Infrastructure Data Classication.pdf

PDF 492 KB Posted

Attached to
Z1AZ--EHRM Infrastructure Upgrades - Phase 2 - Hines, IL 578-21-701 (VA-21-00020757)
Solicitation number
36C77621R0058
Issued by

About this file

This pre-solicitation notice requests Standard Form 330 qualification packages from architecture and engineering firms for design services related to electrical, mechanical, and infrastructure upgrades at the Hines VA Medical Center in Hines, Illinois. The project value is estimated between $20-50 million and has a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Firms must submit SF-330 responses by March 11, 2021 to be considered for a potential design contract award. Evaluation criteria include specialized experience, professional qualifications, capacity, past performance, locality, and construction period experience. The notice describes a two-phase selection process involving an initial evaluation of SF-330s followed by discussions with shortlisted firms.

View the file

Other files

File Type Posted
S02 - SOW Attachment 4 - EHRM Readiness Infrastructure Self-Assessment Hines.xlsx XLSX spreadsheet
S02 - SOW Attachment 21 - OIT Design Guide.pdf PDF
S02 - SOW Attachment 9 - Contractor PIV Instructions and Form.pdf PDF
S02 - SOW Attachment 27 - Above Ceiling Entry and Wall Construction Permits.pdf PDF
S02 - SOW Attachment 16 - VA EHRM Site Infrastructure and EUD Requirements - 1.8.pdf PDF
S02 - SOW Attachment 11 - Contractor Parking.pdf PDF
S02 - SOW Attachment 20 - HEFP SEP-EHRM Training_Admin Space-Planning Job Aid.pdf PDF
36C77621R0058.docx DOCX document
S02 - SOW Attachment 13 - OIT Horizontal Cable Requirements.pdf PDF
S02 - SOW Attachment 5 - Past Performance Questionnaire.docx DOCX document
S02 - SOW Attachment 6 - EHRM Design Schedule.docx DOCX document
S02 - SOW Attachment 18 - OIT Standards Alert 003C2B-SA-017.pdf PDF
S02 - SOW Attachment 2 - SOCAMES 6 Design Alert 1 Hines.pdf PDF
S02 - SOW Attachment 28 - Cutting Welding and Other Hot Work.pdf PDF
S02 - SOW Attachment 10 - No Smoking Policy 10-1-19.pdf PDF
S02 - SOW Attachment 1 - SOW EHRM Infrastructure Upgrades 578-21-701.docx DOCX document
S02 - SOW Attachment 29 - Safety and Health During Construction Activities.pdf PDF
S02 - SOW Attachment 24 - Hines Data Closet Security.pdf PDF
S02 - SOW Attachment 26 - Dig Permit SOP Form.pdf PDF
S02 - SOW Attachment 23 - EHRM Readiness Infrastructure Self-Assessment 2020 10 27.xlsx XLSX spreadsheet
S02 - SOW Attachment 19 - SOCAMES 6 Design Alert 1.pdf PDF
S02 - SOW Attachment 32 - Infection Control Risk Assessment (ICRA).docx DOCX document
S02 - SOW Attachment 8 - Hines Underground Utility Plan.pdf PDF
S02 - SOW Attachment 14 - Fire Protection Code Reviews.pdf PDF
S02 - SOW Attachment 12 - AE Design Checklist.pdf PDF
S02 - SOW Attachment 17 - OIT-InfrastrucStdsTelecommSpaces v3.0.pdf PDF
S02 - SOW Attachment 30 - Pre-Construction Risk Assessment (PCRA).docx DOCX document
S02 - SOW Attachment 31 - Interim Life Safety Measures (ILSM).docx DOCX document
S02 - SOW Attachment 7 - Hines VA Campus Site Plan.pdf PDF
S02 - SOW Attachment 25 - Hines COVID-19 Guidelines.pdf PDF
S02 - SOW Attachment 22 - OIT-Design Guide Templates-CriticalTelecommSpaces.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Veterans Affairs

D\ate: NOV O 7 2018

Memorandum

From: Deputy Under Secretary for Health for Operations and Management (1 ON)

Subj: Sensitive Infrastructure Data Classification - For Official Use Only (FOUO)

To: Veterans Integrated Service Network Directors (10N1-23)

1. This memorandum describes Veterans Health Administration's direction to protect sensitive infrastructure information, including building drawings and related data, for VHA-controlled space. VHA-controlled space includes owned, leased, and delegated Federal facil ities. All information determined to be sensitive shall be marked and managed as FOUO in accordance with this memorandum. This applies to the access to and generation, dissemination, storage, transfer and disposal of all FOUO information related to VHA-controlled space and to procurements to obtain, alter, or manage space, either Government-owned or leased, including VHA space that is delegated to other Federal agencies.

2. Executive Order 13556, signed on November 4, 2010, establishes a program for managing Controlled Unclassified Information, with the National Archives and Records Administration (NARA) serving as the executive agent. The Department of Veterans Affairs is in the process of developing Controlled Unclassified Information (CUI) standards in conformance with the Executive Order and NARA requirements. In advance of agency direction regarding the implementation of CUI, this memorandum specifically identifies and defines sensitive infrastructure information. Due to the increased use and transfer of electronic media it was determined that advance clarification of infrastructure data requirements is necessary. Data types that will be considered sensitive and therefore FOUO is as follows:

a. Facility drawings with technical details (e.g. cross-sections, construction details, wiring diagrams, etc.) on critical or secure areas.

b. Specifications with information on critical or secure areas, associated functions or systems.

c. Reports or investigations pertaining to facilities management or infrastructure containing information on critical or secure areas.

d. Facility Operation and Maintenance data (Preventative Maintenance records, Standard of Procedures. Maintenance and Operation manuals) on critical or secure areas.

Page2

Sensitive Infrastructure Data classification - For Official Use Only (FOUO)

3. Critical or secure areas shall include areas categorized as or like the following, at a minimum:

• Pharmacy vault and dispensing area;

• Agent cashier area;

• Police holding cells and weapons vault;

• National Continuity of Operations (COOP) centers as well as COOP facilities at each VAMC;

• National Emergency Response caches;

• Biological Safety Level - 3 laboratories;

• Security systems (Video Assessment and Surveillance System, Physical Access

Control System, Intrusion Detection System, etc.) and control centers;

• Information Technology room design details; and

• Animal research facility or laboratories.

4. If you have any questions, please feel free to contact Mr. Vincent Rizzo, Compliance Engineer, by phone at (716) 238-5587 or by email at Vincent.Rizzo@va.gov. In addition, please coordinate this guidance with your Network Capital Assets Manager and Medical Center Chief Engineers.