These are architectural and engineering construction documents for the EHRM Training and Admin Support Space project at the VA North Texas Health Care System in Bonham, Texas, with project number 549A4-21-703. The project involves renovating approximately 2,600 square feet across four rooms (321, 406, 407, and 414) on the third and fourth floors of Building 02, including asbestos abatement, interior renovations, lighting upgrades, mechanical systems replacement, and electrical system modifications.
Key renovation details include installing new split-system air conditioning units, reconfiguring demountable partitions, replacing flooring and ceiling tiles, updating lighting with LED fixtures, adding wireless access points, and implementing new power and telecommunications infrastructure. The design incorporates three classrooms and an administrative office area, with careful attention to accessibility standards, life safety requirements, and maintaining existing building systems. The project is being executed at 1201 E 9th St, Bonham, TX 75418, with construction documents dated February 8, 2024, prepared by Valhalla Engineering Group, LLC.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S06 Answers to RFIs training and admin.pdf | ||
| 36C25726R0023 0002_1.docx | DOCX document | |
| S06 CONSTRUCTION SAFETY PIN 2025 EHRM Training and Admin Support.pdf | ||
| S06 36C25726R0023 Sign in Sheet.pdf | ||
| 36C25726R0023 0002.pdf | ||
| 36C25726R0023 0001.pdf | ||
| 36C25726R0023 0001_1.docx | DOCX document | |
| S02 BONHAM CAMPUS Parking.pdf | ||
| S02 PCRA ICRA.pdf | ||
| S02 PN549A4-21-703_100PCT_SPECS.pdf | ||
| S02 36C25726R0023 549A4-21-703 EHRM Training and Admin Support Space.pdf | ||
| 36C25726R0023_2.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N or th
AREA OF PROJECT
N or th
PROJECT SITE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
GI001
COVER EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
VA NORTH TEXAS HEALTH CARE SYSTEM
1201 E 9TH ST, BONHAM, TX 75418
VAMC PROJECT #: 549A4-21-703
EHRM TRAINING AND ADMIN SUPPORT SPACE - BONHAM, TX
SHEET NUMBER SHEET NAME
H-110 ASBESTOS ABATEMENT
GENERAL
GI001 COVER
GI002 GENERAL ABBREVIATIONS, NOTES, & SYMBOLS
GI003 ACCESSIBILITY STANDARDS
GI005 DEPARTMENT PLAN
GI110 CODE DATA, LIFE SAFETY PLANS
HAZARDOUS MATERIALS
HA110 ASBESTOS ABATEMENT PLAN
ARCHITECTURAL
A-001 ARCHITECTURAL ABBREVIATIONS, NOTES, & SYMBOLS
AD110 DEMOLITION PLAN - OVERALL
AD131 DEMOLITION PLAN - ROOF
AE110 FLOOR PLANS - OVERALL
AE111 PLANS - 3RD FLOOR - ROOM 321
AE112 PLANS - 4TH FLOOR - ROOM 406
AE113 PLANS - 4TH FLOOR - ROOM 407
AE114 PLANS - 4TH FLOOR - ROOM 414
AE131 PLAN - ROOF
AE301 BUILDING SECTIONS
AE411 ENLARGED PLANS & DETAILS - DEMOUNTABLE
PARTITIONS
AE531 EXTERIOR DETAILS
AE532 ROOF DETAILS
AE541 INTERIOR DETAILS
AE601 PARTITION TYPE AND DOOR SCHEDULES
AE641 ROOM FINISH SCHEDULE & LEGEND
AE901 PERSPECTIVE RENDERINGS
MECHANICAL
M-001 MECHANICAL ABBREVIATIONS & NOTES
M-002 MECHANICAL SYMBOLS
M-003 OVERALL PLANS
MQ601 EQUIPMENT SCHEDULES
MD111 DEMOLITION PLANS
MD112 DEMOLITION PLANS
MH111 HVAC PLANS
MH112 HVAC PLANS
MP111 PIPING PLANS
MP112 PIPING PLANS
MI111 CONTROLS & INSTRUMENTATION PLANS
MI112 CONTROLS & INSTRUMENTATION PLANS
MI601 CONTROL DIAGRAMS
MK501 TYPICAL DETAILS
MK502 TYPICAL DETAILS
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
E-002 ELECTRICAL SYMBOLS
E-003 OVERALL PLANS - 3RD & 4TH FLOOR OVERALL
ED110 DEMOLITION PLANS - 3RD & 4TH FLOOR OVERALL
ED112 DEMOLITION PLAN - ROOF
EL121 LIGHTING & LIGHTING CONTROLS RCP - ENLARGED
EL601 LIGHTING SCHEDULES
EP111 POWER PLANS - ENLARGED
EP112 POWER PLAN - ROOF
EP601 POWER ONE-LINE DIAGRAM
EP611 PANEL SCHEDULES
ET111 TELECOM PLANS - ENLARGED
EK501 TYPICAL DETAILS
SHEET INDEXRENDERED IMAGEAREA OF WORK
EHRM CLASSROOM - VIEW TOWARDS FRONT OF ROOM
Number: Revision: Date:
0 100% CONSTRUCTION DOCUMENTS 02/08/2024
GENERAL
GI001 COVER
GI002 GENERAL ABBREVIATIONS, NOTES, & SYMBOLS
GI003 ACCESSIBILITY STANDARDS
GI005 DEPARTMENT PLAN
GI110 CODE DATA, LIFE SAFETY PLANS
HAZARDOUS MATERIALS
HA110 ASBESTOS ABATEMENT PLAN
ARCHITECTURAL
A-001 ARCHITECTURAL ABBREVIATIONS, NOTES, & SYMBOLS
AD110 DEMOLITION PLAN - OVERALL
AD131 DEMOLITION PLAN - ROOF
AE110 FLOOR PLANS - OVERALL
AE111 PLANS - 3RD FLOOR - ROOM 321
AE112 PLANS - 4TH FLOOR - ROOM 406
AE113 PLANS - 4TH FLOOR - ROOM 407
AE114 PLANS - 4TH FLOOR - ROOM 414
AE131 PLAN - ROOF
AE301 BUILDING SECTIONS
AE411 ENLARGED PLANS & DETAILS - DEMOUNTABLE
PARTITIONS
AE531 EXTERIOR DETAILS
AE532 ROOF DETAILS
AE541 INTERIOR DETAILS
AE601 PARTITION TYPE AND DOOR SCHEDULES
AE641 ROOM FINISH SCHEDULE & LEGEND
AE901 PERSPECTIVE RENDERINGS
MECHANICAL
M-001 MECHANICAL ABBREVIATIONS & NOTES
M-002 MECHANICAL SYMBOLS
M-003 OVERALL PLANS
MQ601 EQUIPMENT SCHEDULES
MD111 DEMOLITION PLANS
MD112 DEMOLITION PLANS
MH111 HVAC PLANS
MH112 HVAC PLANS
MP111 PIPING PLANS
MP112 PIPING PLANS
MI111 CONTROLS & INSTRUMENTATION PLANS
MI112 CONTROLS & INSTRUMENTATION PLANS
MI601 CONTROL DIAGRAMS
MK501 TYPICAL DETAILS
MK502 TYPICAL DETAILS
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
E-002 ELECTRICAL SYMBOLS
E-003 OVERALL PLANS - 3RD & 4TH FLOOR OVERALL
ED110 DEMOLITION PLANS - 3RD & 4TH FLOOR OVERALL
ED112 DEMOLITION PLAN - ROOF
EL121 LIGHTING & LIGHTING CONTROLS RCP - ENLARGED
EL601 LIGHTING SCHEDULES
EP111 POWER PLANS - ENLARGED
EP112 POWER PLAN - ROOF
EP601 POWER ONE-LINE DIAGRAM
EP611 PANEL SCHEDULES
ET111 TELECOM PLANS - ENLARGED
EK501 TYPICAL DETAILS
ROOM NAME
VIEW TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
ENLARGED CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION OR DETAIL SYMBOL IDENTIFIERS
DETAIL NAME
DRAWING NUMBER
DESIGNATOR ON SHEET
DRAWING SEQUENCE
NUMBER INDICATES
WHERE DRAWING IS
LOCATED
TWO CHARACTER
DISCIPLINE DESIGNATOR
AE101
TO OBJECT
CENTER
COLUMN
BUBBLE
ROOM TAG
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER
ON SHEET
SHEET NUMBER
NEW LINE TYPE
EXISTING LINE TYPE
DEMOLITION LINE TYPE
AREA OF DEMOLITION
VIEW NAME
1/8" = 1'-0"
AE101
AE101
AS101
SYMBOLS LEGEND
AE101
EXTERIOR
INTERIOR
## SHEET KEYNOTE
REVISION TAG
DRAWING SCALE
REFERENCE
KEYNOTE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
######-A######-A
TO OBJECT
FACE OR OTHER
GEOMETRY
1-HR FIRE
2-HR FIRE
3-HR FIRE
4-HR FIRE
1-HR FIRE/SMOKE
2-HR FIRE/SMOKE
3-HR FIRE/SMOKE
4-HR FIRE/SMOKE
0-HR SMOKE 0.5-HR SMOKE
GENERAL ABBREVIATIONS
ABBREVIATIONS LISTED BELOW ARE GENERAL ABBREVIATIONS ACROSS ALL DISCIPLINES. DISCIPLINE SPECIFIC ABBREVIATIONS MAY SUPERSEDE GENERAL ABBREVIATIONS. REFER TO DISCIPLINE SPECIFIC ABBREVIATIONS SHEETS. A. WORK SHALL CONFORM WITH PROJECT SPECIFICATIONS.
B. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS
RELATED TO THE WORK. QUESTIONS WILL BE DIRECTED TO VHA COR.
C. CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS,
AND SEQUENCES OF CONSTRUCTION AND THE SAFETY OF CONSTRUCTION
PERSONNEL AND VISITORS.
D. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP
DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS
WILL BE REJECTED AND RETURNED TO THE CONTRACTOR. REFER TO
SPECIFICATION SECTION 01 33 23.
E. EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL
BE INSTALLED AND REPORT TO THE VHA COR, IN WRITING, CONDITIONS
DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THEIR WORK. DO
NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED.
COMMENCING WITH INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
F. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES.
CONTACT VHA COR FOR CLARIFICATIONS, IF REQUIRED.
G. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR
DIMENSION IS REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR
CONDITIONS THROUGHOUT.
H. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE
DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, ETC), CONTACT VHA CO
FOR CLARIFICATION.
I. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, SPECIFICATIONS GOVERN. CONTACT VHA CO FOR
CLARIFICATION.
J. DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL
BE REPORTED TO THE VHA CO, IN WRITING, FOR RESOLUTION PRIOR TO
PROCEEDING WITH THE WORK.
K. DISCREPANCIES SHALL BE REPORTED TO THE VHA CO IN WRITING FOR
RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. NO CHANGE
ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR
PROCEEDING WITH THE WORK WITHOUT THE CONTRACTING OFFICER'S
WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR SHALL REPAIR
AND/OR REPLACE UNAUTHORIZED WORK, AS INDICATED BY THE VHA COR,
AT NO ADDITIONAL COST TO THE VHA.
L. DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH AN APPROVED
NONMETAL ISOLATION MATERIAL IN ACCORDANCE WITH SPECIFICATIONS.
M. EXTERIOR EXPOSED STEEL SHALL BE PAINTED PER SPECIFICATION SECTION
09 91 00.
N. CONTRACTOR SHALL VERIFY THE LOCATIONS OF EXISTING UNDERGROUND
UTILITIES AND THEIR SERVICE CONNECTIONS WITH THE PROPER UTILITY
COMP, COORDINATE ISSUES WITH VHA COR.
O. CONTRACTOR SHALL COORDINATE SIZE, LOCATIONS AND NUMBER OF ROOF
OPENINGS AND ROOF ACCESSORIES WITH OTHER TRADES. REFER TO THE
ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR REFERENCE AND SPECIFICATIONS FOR REQUIREMENTS.
P. LOCATIONS AND SIZES OF CONCRETE MECHANICAL AND ELECTRICAL
EQUIPMENT PADS SHALL BE COORDINATED WITH THE SELECTED
EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS ARE TO BE
APPROVED BY THE VHA COR PRIOR TO PROCEEDING WITH THE WORK.
Q. AT TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-
RETARDANT-TREATED PLYWOOD SHEATHING OVER TYPE X GYPSUM BOARD.
BOTTOM TO BE LOCATED AT 4" AFF VERIFY LENGTHS AND LOCATIONS WITH
ELECTRICAL DRAWINGS. REFER TO SPECIFICATION SECTION 06 10 00.
R. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE,
ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS,
DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
S. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD AS REQUIRED
FOR THE MOUNTING OF TOILET ACCESSORIES, MILLWORK, CASEWORK, AV
EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC. REFER TO
SPECIFICATIONS.
T. PROPRIETARY PRODUCTS SHOWN ON THE DRAWINGS SHALL MEET
SPECIFICATION REQUIREMENTS.
U. REFER TO SPECIFICATION SECTION 01 45 29 FOR REQUIRED TESTING AND
INSPECTIONS.
V. DURING ABATEMENT, DEMOLITION, AND CONSTRUCTION ACTIVITES, LIFE
SAFETY SYSTEMS SUCH AS FIRE SPRINKLERS, DETECTORS, AND ALARMS
SHALL REMAIN FULLY OPERATIONAL. SMOKE DETECTORS SHALL BE
REPLACED WITH HEAT DETECTORS FOR THE DURATION. REFER TO
SPECIFICATIONS FOR ADDITIONAL SAFETY INFORMATION.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
GI002
GENERAL ABBREVIATIONS, NOTES,
& SYMBOLS
EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
A
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
AD AREA DRAIN
ADJ ADJUSTABLE / ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ATTEN ATTENUATION
AUTO AUTOMATIC
AV AUDIO / VISUAL
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BM BENCH MARK / BEAM
BO BOTTOM OF
BOC BACK OF CURB
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BVL BEVELED
C
CAP CAPACITY
CB CATCH BASIN
CCTV CLOSED CIRCUIT TV
CF CUBIC FEET
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CIP CAST-IN-PLACE
CL CENTER LINE
CLG CEILING
CLR CLEAR / CLEARANCE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION / CONNECT
CONST CONSTRUCT / CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR / CORRUGATED
CP CONCRETE PIPE
CS COUNTERSINK
CU CUBIC
CW COLD WATER
D
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
E
E EAST
EA EACH
EF EXHAUST FAN
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FB FACE BRICK
FBO FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FF FINISH FLOOR
FF&E FIXTURES, FURNITURE & EQUIPMENT
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RATED
FRMG FRAMING
FS FLOOR SINK
FT FOOT/ FEET
FTG FOOTING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GPM GALLON PER MINUTE
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HORIZ HORIZONTAL
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATING / AIR
CONDITIONING
HW HOT WATER
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE (D), (ING)
INFO INFORMATION
INST INSTALL / INSTALLATION
INSUL INSULATE / INSULATION
INT INTERIOR
INV INVERT
J
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
K
KIT KITCHEN
KO KNOCKOUT
L
L LONG / LENGTH
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LRG LARGE
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
M
MAS MASONRY
MAX MAXIMUM
MBR MEMBER
MECH MECHANICAL
MED MEDIUM
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODULAR
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSF NET SQUARE FEET
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD / OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PA PUBLIC ADDRESS
PB PUSH BUTTON
PC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERM PERMANENT
PERP PERPENDICULAR
PL PLATE / PROPERTY LINE
PLUMB PLUMBING
PNL PANEL
PR PAIR
PREFAB PREFABRICATE (D)
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARE (D)
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PVG PAVING
Q
QTY QUANTITY
R
R RISER / RADIUS
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER TO / REFERENCE
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISED/ REVISION
RH RIGHT HAND
RM ROOM
ROW RIGHT OF WAY
RR RESTROOM
RTU ROOF TOP UNIT
S
S SOUTH
SAN SANITARY SEWER
SCH SCHEDULE
SCRN SCREEN
SECT SECTION
SF SQUARE FOOT (SQFT)
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SPKLR SPRINKLE
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD (SQ YD)
SYM SYMMETRICAL / SYMBOL
SYS SYSTEM
T
TEL TELEPHONE
TEMP TEMPORARY / TEMPERED
THK THICK (NESS)
THRU THROUGH
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STEEL
TOW TOP OF WALL
TRANSF TRANSFORMER
TV TELEVISION
TYP TYPICAL
U
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
VEST VESTIBULE
VHA VETERANS HEALTH ADMINISTRATION
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W
W WEST, WIDTH, WIDE
W/ WITH
W/IN WITHIN
W/O WITHOUT
WC WATER CLOSET
WH WALL HYDRANT / WATER HEATER
WT WEIGHT
X, Y, Z, MISC
& AND
@ AT
YD YARD
Number: Revision: Date:
0 100% CONSTRUCTION DOCUMENTS 02/08/2024
A. ALL DIMENSIONS ARE MEASURED FROM THE FINISH FLOOR AND THE FINISH WALL, UNLESS NOTED OTHERWISE. ACCESSIBILITY GUIDELINES ARE BASED ON “PG-18-13 VA BARRIER FREE DESIGN
STANDARD” AND THE “ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS).”
B. ACCESSIBLE UNOBSTRUCTED REACH RANGES:
1. FORWARD REACH = 15" MIN TO 48" MAX
2. SIDE REACH = 15" MIN TO 48" MAX
C. DOOR HARDWARE (TO CENTER OF HARDWARE):
STANDARD MOUNTING HEIGHTS:
1. PUSH PLATES = 42"
2. PULL HANDLES = 42"
3. KNOBS / LEVERS = 40"
4. PANIC DEVICE = 42" CL OF BAR
5. KICKPLATES:
a. WIDTH = DOOR WIDTH MINUS 2"
b. CENTER HEIGHT = 16" FROM BO DOOR
6. THRESHOLDS:
a. STANDARD = 1/2" MAX
b. EXTERIOR SLIDING DOORS = 3/4" MAX
D. COUNTERTOPS (TO SINK RIM / COUNTERTOP):
E. ACCESSIBLE = 28" MIN TO 34" MAX
SHELVES: ACCESSIBLE = 48" MAX
F. COAT HOOKS:
1. STANDARD = 68"
2. ACCESSIBLE = 48" MAX
G. CHALKBOARDS, TACKBOARDS & MARKERBOARDS:
1. STANDARD = 32" TO 39" (TO BO BOARD OR CHALK TRAY)
2. STANDARD = 80" (RECOMMENDED, TO TOP OF BOARD)
H. THERMOSTATS & CONTROL DEVICES (TO TOP):
1. ACCESSIBLE FORWARD REACH = 48" MAX
2. ACCESSIBLE SIDE REACH = 48" MAX
I. LIGHT SWITCHES & CARD READERS (TO CL):
1. LOCATE 6" FROM DOOR JAMB
2. ACCESSIBLE = 48" MAX
J. CONVENIENCE RECEPTACLES / ELECTRICAL / TELEPHONE / DATA (TO CL):
1. STANDARD = 18"
2. ACCESSIBLE = 15" MIN
K. EXIT LIGHTS - WALL MOUNTED:
1. 2" BELOW CEILING
2. 2" MIN ABOVE DOOR FRAME EQUAL SPACE FROM CEILING TO TOP OF FRAME
L. FIRE EXTINGUISHERS (TO TOP UNLESS NOTED OTHERWISE):
1. GROSS WT 40 LBS OR LESS = 60" MAX
2. GROSS WT MORE THAN 40 LBS = 42" MAX
3. ACCESSIBLE = 40" MAX (TO BO CABINET)
M. FIRE ALARM PULL STATION (TO LEVER):
1. STANDARD = 48" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX
3. ACCESSIBLE SIDE REACH = 48" MAX
N. SMOKE AND / OR HEAT DETECTORS:
1. STANDARD = CEILING HEIGHT
O. HORN / SPEAKER / VISUAL SIGNALS:
1. STANDARD = 80" AFF OR 6" BELOW CEILING - WHICHEVER IS LOWER
P. ROOM SIGNAGE (TO CL):
1. STANDARD = 60" HIGH AFF & WITHIN 18" OF LATCH SIDE OF DOOR
GENERAL NOTES
MIN
8"
M
IN9"
M
IN
2'
MIN
11"
6" MAX
MAX
1' - 5"
M
IN9"
ELEVATION (TC) ELEVATION (KC)PLAN (TC) PLAN (KC)
M
IN
2'
25" MAX
M
IN
2'
17" MIN - 25" MAX
CFGSCFGS
KC
TC
PULL SIDE
PUSH SIDE
2' - 0" MIN
2' - 0" MIN
PULL SIDE
PUSH SIDE
1' - 10" MIN
3' - 0" MIN
PULL SIDE
PUSH SIDE
1' - 10" MIN
3' - 6" MIN
PULL SIDE
PUSH SIDE
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
APPROACH
APPROACH
MIN
1' - 0"
MIN
1' - 6"
4'
M
IN
5'
M
IN
PER FRAME DETAILS
4'
M
IN
4'
M
IN
4'
M
IN
5'
M
IN
4'
M
IN
4'
M
IN
(A) CLEAR FLOOR SPACE, PARALLEL APPROACH (B) HIGH AND LOW SIDE REACH (C) MAXIMUM SIDE REACH OVER OBSTRUCTIONS
4'
2' - 6"
MAX
10"
M A
X
2'
0"
2' - 0" 2' - 2"
M A
X
4'
LIGHT SWITCH
M A
X
4'
MAX
1' - 0"
2"
THERMOSTAT
M
IN
1'
RECEPTACLE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
GI003
ACCESSIBILITY STANDARDS EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
NTS
TOE CLEARANCE (TC) & KNEE CLEARANCE (KC)
C6
1/2" = 1'-0"
TYP DOOR JAMB & DOOR MANUEVERING CLEARANCES
B4
NTS
ACCESSIBILITY REACH
D7
NTS
SWITCH @ DOOR
E8
412A
411B
411A
0F
400E
410A 400A
0C
301A
323 324
300F
326B
326A
300B
324A
324B
324C
323A
323B
323C
1 2 3 4 5 6
A
B
C
D
E
F
G
ADMINISTRATION
OFFICE AREA
635 SF
EHRM CLASSROOM
639 SF
EHRM CLASSROOM
140 SF
414A
RECEPTION
122 SF
414B
CONFERENCE
DEPARTMENT LEGEND
ADMIN
CLASSROOM
1211109
A
B
C
D
E
F
G
633 SF
EHRM CLASSROOM
A. REFER TO GI002 AND A-001 FOR SYMBOLS, ABBREVIATIONS AND ADDITIONAL
GENERAL NOTES.
B. REFER TO LIFE SAFETY PLAN FOR EGRESS INFORMATION.
C. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION.
D. REFER TO OTHER DISCIPLINES FOR ADDITIONAL INFORMATION.
NOT IN CONTRACT
PLAN LEGEND
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
RM 321RM 407 & 406
RM 414
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
GI005
DEPARTMENT PLAN EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/8" = 1'-0"
DEPARTMENT PLAN - 4TH FLOOR WEST
F1 1/8" = 1'-0"
DEPARTMENT PLAN - 3RD FLOOR EAST
F5
DEPARTMENT SCHEDULE
ROOM NAME DEPARTMENT
ROOM
AREA
ADMINISTRATION OFFICE AREA ADMIN 437 SF
CONFERENCE ADMIN 122 SF
RECEPTION ADMIN 140 SF
EHRM CLASSROOM CLASSROOM 635 SF
EHRM CLASSROOM CLASSROOM 639 SF
EHRM CLASSROOM CLASSROOM 633 SF
412A
411B
411A
0F
400E
410A 400A
400D
0C
402A
400404
1A
415 416
400B
420B
421A
420A
400G
418417
0H
302A 301
301A
300C
304305
323 324
330B
0H
328B
328D328C
327B
8A
300F
327A
326B
326A
300B 300A
306307308309
0E
320A
320B
300D
313A
312 311A
327C
327D
327E
324A
324B
324C
323A
323B
323C
330A
330C
1 2 3 4 5 6 7 8 14131211109
A
B
C
D
E
F
G
EX
EX
EX
136 FT 91 FT
635 SF
EHRM CLASSROOM
639 SF
EHRM CLASSROOM
SC SC
437 SF
ADMINISTRATION
OFFICE AREA
140 SF
414A
RECEPTION
414B
CONFERENCE
FEC
FEC
FEC
43 43
IES-ST-4IES-ST-4
IES-ST-4
1 2 3 4 5 6 7 8 14131211109
A
B
C
D
E
F
G
EX
EX
EX
633 SF
EHRM CLASSROOM
SC SC
157 FT95 FTFEC
FEC FEC
FEC
IES-ST-3IES-ST-3
IES-ST-3
LIFE SAFETY LEGEND
EXIT STAIR [ INTERIOR EXIT STAIRWAY : IES ]
ST : STORY, X : IES DESIGNATION
EXIT ACCESS CORRIDOR (EAC)
EAC - PUBLIC (SOLID)
EAC - STAFF (DASHED)
STAIRWAYS
EXIT ACCESS (EA)
EA EXIT ACCESS (EA)
EX EXIT (EX)
EXIT SIGNS (ES)
HAZARDOUS AREAS
VERTICAL OPENINGS (VO)
VO - Shaft
VO - Hoistway
HA - STORAGE
IES-ST-X
SMOKE COMPARTMENT (1-WAY OR 2-WAY)SC
(XXX'-X")
START
POINT
END
POINT
DISTANCE
TYPE
AREAS
EXITS (EX)
EXIT ACCESS TRAVEL DISTANCE (EATD)
N
INDICATES NUMBER OF OCCUPANTS
(N = OCCUPANTS)
MISCELLANEOUS
FIRE EXTINGUISHER CABINET (FEC)
CLASSROOMS/CONFERENCEBUSINESS
EXIT PATHS
FEC
CODE COMPLIANCE SUMMARY
REQUIRED CODES
OCCUPANCY
CLASSIFICATION:
OCCUPANT LOAD:
NUMBER OF EXITS:
WIDTH OF EXITS:
COMMON PATH OF TRAVEL:
TRAVEL DISTANCE TO EXIT:
THIS PROJECT INVOLVES THE RENOVATION OF FOUR EXISTING ROOMS WITHIN
BUILDING 2 AT THE SAM RAYBURN VAMC. BUILDING 2 IS OF CONCRETE AND
MASONRY CONSTRUCTION, BUILT IN 1948. ASBESTOS ABATEMENT WILL BE
REQUIRED (2,600 SF). THE TOTAL AREA OF INTERIOR RENOVATION (FINISHES,
LIGHTING, ELECTTRICAL, DATA, HVAC) IS APPROXIMATELY 2600 SF, PLUS
APPROXIMATELY 100 SF OF ROOF RENOVATION WORK FOR NEW MECHANICAL
EQUIPMENT. THE 4 ROOMS TO BE RENOVATED INCLUDE ROOM 321, 406, 407,
AND 414, WITH THE FIRST 3 BEING TEMPORARY EHRM CLASSROMS, AND THE
FOURTH BEING AN OFFICE AREA. NO CHANGES TO INTERIOR WALLS OR
EXTERIORS WINDOWS WILL OCCUR.
NFPA 101, LIFE SAFETY
CODE, 2021 EDITION
IBC 2021
304.1
BUSINESS GROUP B
EXISTING BUSINESS
(CHAPTER 39)
2021 NFPA 101 LIFE SAFETY CODE (LSC)
2021 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL FIRE CODE (IFC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2023 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)
2023 VA HVAC DESIGN MANUAL
2023 VA PLUMBING DESIGN MANUAL
2014 ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)
2023 VA SUPPLEMENT BARRIER FREE DESIGN
TABLE 7.3.1.2 TABLE 1004.5/RE: 1004.8
SPRINKLER SYSTEM 903.2.2 GROUP B
SPRINKLER SYSTEM PER
903.
39.2.4.1
2 EXITS REQUIRED PER
STORY MINIMUM
39.2.3.2
MINIMUM 44 INCHES
39.2.5.2.1
MAXIMUM 100 FEET
TABLE 1017.2 -
MAXIMUM 200 FT
39.2.6
MAXIMUM 300 FT
DEAD-END CORRIDORS SECTION 1020.5
MAXIMUM 20 FT
39.2.5.3
MAXIMUM 50 FT
TABLE 1006.2.1
MAXIMUM 100 FEET
SECTION 1024
MINIMUM 44 INCHES
SECTION 1006
2 EXITS REQUIRED
39.2.6.3
SPRINKLER SYSTEM
PER 9.7
633 GSF = 42.2 = (43) OCC
PROJECT DESCRIPTION
(15 GSF / OCC) [ROOM 321]
FIRE SEPARATION 7.1.3.2.1
1 HOUR
TABLE 508.4/509.1
1 HOUR OR AUTOMATIC
SPRINKLER SYSTEM
CONSTRUCTION RATINGS: NFPA 5000 TABLE 7.2.1.1
FLOOR-CEILING
ASSEMBLIES: 2 HR
TABLE 601
FLOOR
CONSTRUCTION: 2 HR
639 GSF = 42.6 = (43) OCC
(15 GSF / OCC) [ROOM 406]
635 GSF = 42.3 = (43) OCC
(15 GSF / OCC) [ROOM 407]
699 GSF = 46.6 = (47) OCC
(15 GSF / OCC) [ADMIN]
633 GSF = 12.6 = (13) OCC
(50 GSF / OCC)
639 GSF = 12.8 = (13) OCC
(50 GSF / OCC)
635 GSF = 12.7 = (13) OCC
(50 GSF / OCC)
699 GSF = 13.9 = (14) OCC
(50 GSF / OCC)
NOT IN CONTRACT
PLAN LEGEND
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
RM 321RM 407 & 406
RM 414
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
GI110
CODE DATA, LIFE SAFETY PLANS EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/16" = 1'-0"
LIFE SAFETY PLAN - 4TH FLOOR
C1
1/16" = 1'-0"
LIFE SAFETY PLAN - 3RD FLOOR
F1
301A
323 324
300F
326B
326A
300B
324A
324B
324C
323A
323B
323C
412A
411B
411A
0F
400E
410A 400A
0C
1211109
A
B
C
D
E
F
G
633 SF
MIN
5' - 0"
M
IN
1 2 3 4 5 6
A
B
C
D
E
F
G
437 SF
635 SF
639 SF
1 1
M
IN
4M
IN
2 2
140 SF
414A
122 SF
414B
A. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA. REFER TO SHEET
AD110 FOR ADDITIONAL INFORMATION.
B. ABATEMENT SHALL TAKE PLACE PRIOR TO STARTING DEMOLITION WORK.
C. CONTRACTOR SHALL REFER TO HAZARDOUS MATERIALS SURVEY AVAILABLE
FROM THE VA COR PRIOR TO COMMENCING WORK.
D. ANY MATERIAL AFFECTED BY DEMOLITION OR CONSTRUCTED SUSPECTED
OF CONTAINING ASBESTOS CONTAINING MATERIALS OR LEAD SHALL BE
REPORTED TO THE VA COR PRIOR TO PROCEEDING WITH WORK.
E. AVOID TOUCHING ANY ABOVE CEILING ASBESTOS CONTAINING MATERIALS,
PARTICULARLY THOSE ITEMS CONTAINED ABOVE EXISTING PLASTER
CEILINGS.
AREA OF FLOORING ABATEMENT
ASBESTOS ABATEMENT PLAN SYMBOLS LEGEND
DEMOLITION LINE TYPE
EXISTING LINE TYPE
NOT IN CONTRACT
TEMPORARY CONSTRUCTION BARRIER
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
RM 321RM 407 & 406
RM 414
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
HA110
ASBESTOS ABATEMENT PLAN EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/8" = 1'-0"
ASBESTOS ABATEMENT PLAN - 3RD FLOOR EAST
F51/8" = 1'-0"
ASBESTOS ABATEMENT PLAN - 4TH FLOOR WEST
F1
Number: Revision: Date:
0 100% CONSTRUCTION DOCUMENTS 02/08/2024
1. ABATE ASBESTOS CONTAINING FLOORING AND MASTIC
2. EXTENT OF PLASTER CEILING ABOVE LAY-IN CEILING. BARRIER FOR
ASBESTOS CONTAINING MATERIALS - DO NOT DISTURB
3. CLOSET AND DOOR TO BE REMOVED
4. PROPOSED LOCATION OF TEMPORARY 1 HOUR FIRE/SMOKE RATED
CONSTRUCTION BARRIERS. VERIFY WITH COR. CONSTRUCTION BARRIER
TO UNDERSIDE OF DECK
ARCHITECTURAL ABBREVIATIONS
ABBREVIATIONS LISTED BELOW ARE SPECIFIC TO ARCHITECTURAL. REFER TO GI002 FOR “GENERAL ABBREVIATIONS” USED BY MULTIPLE DESIGN DISCIPLINES.GI002 A. DIMENSIONS ON FLOOR PLANS ARE TO THE FACE OF GYPSUM BOARD (FOG), FACE OF EXPOSED MASONRY (FOM), FACE OF CONCRETE WALLS (FOC) AND
COLUMN GRID LINES, UNLESS OTHERWISE NOTED.
B. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN
WALLS AND FOUNDATIONS, BETWEEN WALL PANELS, AT PENETRATIONS
THROUGH THE BUILDING ENVELOPE, ETC, SHALL BE SEALED, CAULKED,
FLASHED OR WEATHER-STRIPPED AS REQUIRED BY SPECIFICATION SECTION
07 92 00.
C. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING
INTERIOR MATERIALS, IE WINDOW SILLS TO GYP BD, ACT CEILINGS TO
MASONRY WALLS, ETC. REFER TO SPECIFICATION SECTION 07 92 00.
D. WALL AND COLUMN GYPSUM BOARD FACING SHALL BE HELD BELOW
STRUCTURE, EXCEPT AT FIRE-RATED PARTITIONS, UNLESS NOTED
OTHERWISE. COORDINATE WITH STRUCTURAL.
E. CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM FINISHED
FLOOR TO FINISH CEILING.
F. CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER SHALL
HAVE THE SAME FINISHES AS ADJOINING SPACES, UNLESS NOTED
OTHERWISE.
ARCHITECTURAL GENERAL NOTES
EARTH /
COMPACT FILL
GRAVEL /
GRANULAR FILL
CONCRETE
SAND / MORTAR /
PLASTER / CUT STONE
BRICK
CONCRETE
MASONRY UNIT
STONE (ELEVATION)
BATT INSULATION
RIGID INSULATION
ACOUSTICAL TILE
(SECTION)
GYPSUM BOARD
COVER BOARD
STEEL / METAL
FINISH WOOD
CONTINUOUS WOOD
BLOCKING / ROUGH
FRAMING
CAST STONE
DISCONTINUOUS
WOOD BLOCKING /
SHIM
PLYWOOD / OSB
FIREPROOFING
METAL / WALL PANELS
SPANDREL GLASS
MATERIALS LEGEND
PLASTIC LAMINATE
DOOR
NUMBER TAG
WALL
TYPE TAG
WINDOW
TYPE TAG
ARCHITECTURAL SYMBOLS LEGEND
REFERENCE
KEYNOTE
W3W3
######-A######-A
S3AS3A
CASEWORK TAG
34 2424
34 2424
CDS
CASEWORK DEPTH (IN)
CASEWORK HEIGHT (IN).
TOP OF COUNTER FOR
BASE CABINETS
CASEWORK WIDTH (IN)
EQUIPMENT
KEYNOTE
A####A####
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
A-001
ARCHITECTURAL ABBREVIATIONS,
NOTES, & SYMBOLS
EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
A
ACP ACOUSTICAL CEILING PANEL
ACST ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
APC ARCHITECTURAL PRECAST CONCRETE
AWP ACOUSTICAL WALL PANEL
B
BITUM BITUMINOUS
BLKG BLOCKING
C
C COURSE
CAB CABINET
CC CONTRACTOR ACQUIRED, CONTRACTOR
INSTALLED
CDS CABINET DESIGN SERIES
CFGS CLEAR FLOOR OR GROUND SPACE
CG CORNER GUARD
CJ CONTROL JOINT
CLOS CLOSET
CMT CERAMIC MOSAIC TILE
CPT CARPET
CSMT CASEMENT
CT CERAMIC TILE
D
DH DOUBLE HUNG
DISP DISPENSER
DMT DEMOUNTABLE
DS DOWNSPOUT
E
EJ EXPANSION JOINT
ELAST ELASTOMERIC
ESC ESCALATOR
EXP EXPANSION / EXPOSED
F
FAB FABRIC
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH / FINISHED
FLG FLOORING
FOF FACE OF FINISH
FOG FACE OF GYPSUM BOARD / WALL
FOS FACE OF STUDS
FRP FIBER REINFORCED PANEL
FUR FURRING
G
GB GRAB BAR
GFRC GLASS FIBER REINFORCED CONCRETE
GL GLASS / GLAZING
GSF GROSS SQUARE FEET
GYP GYPSUM
H
HD HEAD
HDBD HARDBOARD
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HK HOOK
HM HOLLOW METAL
I
ICRA INFECTION CONTROL RISK ASSESSMENT
ILSM INTERIM LIFE SAFETY MEASURES
K
KC KNEE CLEARANCE
KPL KICK PLATE
L
LAM LAMINATE (D)
LVT LUXURY VINYL TILE
M
MDF MEDIUM DENSITY FIBERBOARD
MEMB MEMBRANE
MO MASONRY OPENING
MULL MULLION
N
NRC NOISE REDUCTION COEFFICIENT
P
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PNT PAINT
POLY POLYETHYLENE
PT PORCELAIN TILE
PTN PARTITION
Q
QT QUARRY TILE
QTB QUARRY TILE BASE
R
RB RESILIENT BASE
REF REFRIGERATOR
RFG ROOFING
RO ROUGH OPENING
RSF RESILIENT SHEET FLOORING
S
SC SOLID CORE
STC SOUND TRANSMISSION COEFFICIENT
T
T TREAD
TC TOE CLEARANCE
TG TONGUE & GROOVE
TKBD TACK BOARD
TPO THERMOPLASTIC POLYOLEFIN
TZ TERRAZZO
U
UNFIN UNFINISHED
V
VB VAPOR BARRIER (VPR BR)
VC VHA ACQUIRED, CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VNR VENEER
VV VHA ACQUIRED, VHA INSTALLED
VWC VINYL WALLCOVERING
W
WB WOOD BASE
WD WOOD
WDW WINDOW
WP WATERPROOFING / WORKING POINT
WR WEATHER RESISTANT
WSF WELDED SEAM SHEET FLOORING
WWF WELDED WIRE FABRIC
X
XPS EXTRUDED POLYSTYRENE
323 324
300F
326B
326A
300B
324A
324B
324C
323A
323B
323C
412A
411B
411A
0F
400E
410A 400A
0C
1211109
A
B
C
D
E
F
G
MIN
5' - 0"
M
IN
10 10
1 2 3 4 5 6
A
B
C
D
E
F
G
407 406
1 1
2 2
M
IN
9M
IN
11 11
10 10 1010
12 5
A. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA.
B. REFER TO OTHER DISCIPLINES FOR RELATED DEMOLITION WORK.
C. AT EXISTING COLUMNS AND WALLS WHERE APPLICABLE, GRIND TERRAZZO
COVE BASE FLUSH WITH THE VERTICAL WALL TO ALLOW INSTALLATION OF
NEW RESILIENT WALL BASE. VERIFY IN FIELD.
D. EXISTING SEMI-RECESSED STEAM RADIATORS SHALL REMAIN IN PLACE.
REFER TO SPECIFICATIONS.
E. EXISTING WINDOWS AND WINDOW SILLS SHALL REMAIN IN PLACE AND BE
CLEANED.
F. AFTER A/C WINDOW UNITS ARE REMOVED, CLEAR THE SUPPORT DEBRIS AND
CLOSE AND SECURE THE WINDOWS.
G. EXISTING WINDOW TREATMENTS (SHADES, VERTICAL BLINDS, ETC.) SHALL
BE REMOVED AT THE THREE CLASSROOMS.
H. CEILINGS: ALL EXISTING LIGHTING FIXTURES, ACOUSTIC CEILING TILES AND
GRID TO BE REMOVED AND SALVAGED PER VHA COR.
I. REFER TO SHEET ED110 FOR WAP TO REMAIN.
AREA OF DEMOLITION
DEMO PLAN SYMBOLS LEGEND
DEMOLITION LINE TYPE
EXISTING LINE TYPE
NOT IN CONTRACT
TEMPORARY CONSTRUCTION BARRIER
5/8" GYPSUM BOARD EACH SIDE
CEILING AS INDICATED ON RCP
CONTINUOUS METAL RUNNERS BOTTOM
SECTION VIEW
BOTTOM OF
FLOOR/ROOF CONST
METAL STUDS WITH HORIZONTAL BRACING
AS REQ'D
FINISHED CEILING HEIGHT
RE RCP
FINISHED FLOOR
CONTINUOUS SEALANT AT SOUND/SMOKE WALLS
METAL STUDS WITH HORIZONTAL BRACING
AS REQ'D
CONTINUOUS SEALANT AT
SOUND/SMOKE WALLS
DEFLECTION TRACK AT TOP
1" G
A P
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
RM 321RM 407 & 406
RM 414
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
AD110
DEMOLITION PLAN - OVERALL EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/8" = 1'-0"
DEMO PLAN - 3RD FLOOR EAST
F51/8" = 1'-0"
DEMO PLAN - 4TH FLOOR WEST
F1
1. REMOVE FLOORING AND ABATE ASBESTOS CONTAINING MATERIALS
2. REMOVE CONCRETE LOCKER BASE.
3. REMOVE DOOR PANEL. FRAME TO REMAIN.
4. REMOVE CLOSET AND DOOR.
5. REMOVE WALL COVERING.
6. REMOVE AND SALVAGE CEILING MOUNTED PROJECTOR SCREEN. RETURN
TO VHA
7. REMOVE CHAIR RAIL.
8. RECONFIGURE EXISTING DIRTT WALLS AND SLIDING DOOR.
9. PROPOSED LOCATION OF TEMPORARY 1 HOUR FIRE/SMOKE RATED
CONSTRUCTION BARRIERS. VERIFY WITH COR. CONSTRUCTION BARRIER
TO UNDERSIDE OF DECK
10. PARTIALLY DEMO WALL AT LOCATION OF NEW LOUVER PENETRATION; RE:
MECH
11. EXTENT OF PLASTER CEILING ABOVE LAY-IN CEILING. BARRIER FOR
ASBESTOS CONTAINING MATERIALS - DO NOT DISTURB
12. EXISTING WINDOW COVERINGS TO REMAIN.
Number: Revision: Date:
0 100% CONSTRUCTION DOCUMENTS 02/08/2024
1" = 1'-0"
TEMPORARY CONSTRUCTION BARRIERS
F7
A. REFER TO GI002 AND A-001FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
B. REFER TO OTHER DISCIPLINES FOR ADDITIONAL DEMOLITION INFORMATION.
C. PRIOR TO CONSTRUCTION INTO ROOF, CONTRACTOR SHALL INSPECT ROOF
AND UNDERSIDE OF ROOF PENETRATIONS FOR ASBESTOS AND NOTIFY COR
OF RESULTS. NO WORK WILL BE DONE IN OCCUPIED SPACES.
1 2 3 4 5 6 7 8 11109
A
B
C
D
E
F
G
1 2
2 1 2
1 2
AREA OF DEMOLITION
DEMO PLAN SYMBOLS LEGEND
DEMOLITION LINE TYPE
EXISTING LINE TYPE
NOT IN CONTRACT
TEMPORARY CONSTRUCTION BARRIER
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
ROOF PLAN
BLDG 02
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:1
P
M
AD131
DEMOLITION PLAN - ROOF EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/8" = 1'-0"
DEMOLITION PLAN - ROOF
F1
1. LOCATION OF NEW ROOFTOP MECHANICAL EQUIPMENT; HOLES TO BE
PENETRATED INTO ROOFSLAB.
2. REFER TO MECHANICAL DRAWINGS, ROOF NEEDS TO BE
REMOVED/PATCHED FOR INSTALLATION OF NEW MECHANICAL EQUIPMENT
323 324
300F
326B
326A
300B
324A
324B
324C
323A
323B
323C
412A
411B
411A
0F
400E
410A 400A
400D
0C
1211109
A
B
C
D
E
F
G
AE111
F7
EHRM CLASSROOM
1 2 3 4 5 6
A
B
C
D
E
F
G
AE113
F7
AE114
F7
AE112
F7
ADMINISTRATION
OFFICE AREA
EHRM CLASSROOM
EHRM CLASSROOM
xAE201
C1
AE531
D6
414B
CONFERENCE
A. REFER TO GI002 AND A-001 FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
NOT IN CONTRACT
PLAN LEGEND
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
RM 321RM 407 & 406
RM 414
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:2
P
M
AE110
FLOOR PLANS - OVERALL EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/8" = 1'-0"
FLOOR PLAN - 3RD FLOOR EAST
F51/8" = 1'-0"
FLOOR PLAN - 4TH FLOOR WEST
F1
T C
LI
G N
D
E
AE111 E1
EHRM CLASSROOM
C2
F1
B2
F2B
F2B
F2B
F2B
F2B
F2B
E5
AE541
F4
AE301
AE541
C3
TYP
F2B
D
E
3'
EQ EQ
EHRM CLASSROOM
E5
AE541
8' - 6"
6' - 8" 6' - 8"
D
E
EHRM CLASSROOM
6'
F5
AE541
AE541
C3
AE541
C3
F7
AE541
SIM
TYP
D
E
AE111 E1
C2
F1
B2
EHRM CLASSROOM
A1033
M0515
M1801
F2025
F0205
F2105
F0435
F3050
E0042
IN0404
F3050
F3050
F3050
F3050
F3050
F3050
F3050
F3050
F3050
3'
/3
PNT-4 PNT-4
3'
FINISH LEGEND
NOT IN CONTRACT CPT - 1 (CARPET TILE)
CPT - 2 (CARPET TILE)
LVT - 1 (LUXURY VINYL TILE)
LVT - 2 (LUXURY VINYL TILE)
AIR TERMINALS, RE MECH
CEILING HEIGHT AFF
REFLECTED CEILING PLAN SYMBOLS LEGEND
LIGHT FIXTURES, RE ELEC
ACT AS SCHEDULED
GWB AS SCHEDULED
OPEN TO STRUCTURE
SPRINKLERS, SEE FIRE
SUPPRESSION DRAWINGS
A. REFER TO GI002 AND A-001 FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
B. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA.
C. EXISTING SEMI-RECESSED STEAM RADIATORS SHALL REMAIN IN PLACE AND
BE CLEANED AND REFURBISHED.
D. EXISTING WINDOWS AND WINDOW SILLS SHALL REMAIN IN PLACE AND BE
CLEANED AND REFURBISHED AS NECESSARY, INCLUDING REPAINTING.
WHERE WINDOW SILLS DO NOT EXIST, SOLID SURFACE SILL SHALL BE
ADDED.
E. WINDOWS SHALL RECEIVE NEW WINDOW TREATMENTS (TRANSLUCENT
SHADES) AT CLASSROOMS.
F. WINDOW TREATMENTS IN ADMINISTRATION OFFICE SHALL REMAIN IN PLACE.
RECONFIGURE WHERE DIRTT WALLS ARE REMOVED OR ADDED.
G. ALL EXTERIOR CORNERS SHALL HAVE FULL HEIGHT CORNER GUARDS AS
SCHEDULED.
H. ALL FURNITURE AND EQUIPMENT SHOWN IS A SUGGESTED LAYOUT AND IS
TO BE PROVIDED BY THE EHRM DEPARTMENT AND VAMC FACILITY AND IS
NOT PART OF THIS CONTRACT. ITEMS THAT ARE MOUNTED, SUCH AS WHITE
BOARDS AND WALL CEILING MOUNTED MONITORS, SHALL HAVE REQUIRED
BLOCKING OR SUPPORTS AND BE INSTALLED BY THE CONTRACTOR.
I. BOTTOM OF EXISTING BEAMS AND SPRINKLER HEADS TO BE FIELD VERIFIED
TO CONFIRM EXACT HEIGHT OF ACOUSTIC CEILING MOUNTING.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
RM 321
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:2
P
M
AE111
PLANS - 3RD FLOOR - ROOM 321 EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/4" = 1'-0"
FLOOR PLAN - 3RD FLOOR ROOM 321
F7
1. PATCH AND PREP FLOOR FOR NEW FLOOR FINISHES. FLOAT FLOOR.
2. REPAIR AND REPAINT HOLLOW METAL DOOR FRAME. REFINISH THE
CLASSROOM DOORS BOTH SIDES.
3. REPLACE RADIATOR COVER INSTALLED OVER UNIT.
4. PATCH, REPAIR, AND SKIMCOAT ENTIRE PLASTER OR GYPSUM BOARD
WALL FOR NEW INTERIOR FINISH AS APPROVED BY VAMC INTERIOR
DESIGNER.
5. TRANSLUCENT SHADES (2 AT 7'-2" WIDE, VIF).
1/4" = 1'-0"
REFLECTED CEILING PLAN - 3RD FLOOR - ROOM 321
C7
1/4" = 1'-0"
FINISH PLAN - 3RD FLOOR - ROOM 321
F5
1/4" = 1'-0"
EQUIPMENT PLAN - 3RD FLOOR - ROOM 321
C53/8" = 1'-0"
INTERIOR ELEVATION - 3RD FLOOR - ROOM 321 - SOUTH
C2
3/8" = 1'-0"
INTERIOR ELEVATION - 3RD FLOOR - ROOM 321 - WEST
F1
3/8" = 1'-0"
INTERIOR ELEVATION - 3RD FLOOR - ROOM 321 - NORTH
B2
3/8" = 1'-0"
INTERIOR ELEVATION - 3RD FLOOR - ROOM 321 - EAST
E1
C C = CONTRACTOR ACQUIRED, CONTRACTOR INSTALLED
V C = VAMC ACQUIRED, CONTRACTOR INSTALLED
V V = VAMC ACQUIRED, VAMC INSTALLED
FF&E PROCUREMENT LEGEND
EQUIPMENT SCHEDULE
JSN DESCRIPTION
ACQ /
INS
A1033 LOCKERS WITH COAT ROD VC
E0042 WORKCENTER, COMPUTER, FREE STANDING, 48 IN VV
F0205 CHAIR, SIDE WITH ARMS VV
F0435 MEDIA STORAGE CABINET VV
F2025 RECYCLING OR TRASH BIN VV
F2105 LECTURN VV
F3050 WHITEBOARD VC
IN0404 SIGN, SECONDARY ROOM IDENTIFICATION VC
M0515 MOBILE CLASSROOM TELEVISION VV
M1801 LAPTOP COMPUTER VV
T C
5 6
D
E
AE112F1
B2
E1
C2
EHRM CLASSROOM
F2B
F2B
F2B F2B
F2B
F2B
4 53
E5
AE541
C4
AE301
AE541
C3
TYP
5 6
D
E
AE112F1
B2
E1
C2
EHRM CLASSROOM
M0515
A1033 F2025
E0042 M1801
F0205
A1033
F3050
F0435
F2105
IN0404
F3050
F3050
F3050
F3050
F3050
F3050
F3050
F3050
F3050
5 6
D
E
EHRM CLASSROOM
6'
F5
AE541
F7
AE541
AE541
C3
AE541
C3
TYP
SIM
5 6
D
E
EHRM CLASSROOM
3'
EQ EQ
8' - 6"
6' - 8" 6' - 8"
PNT-5 PNT-5
F3050F3050F3050F3050F3050
3'
F3050 F3050 F3050 F3050 F3050
3'
FINISH LEGEND
NOT IN CONTRACT CPT - 1 (CARPET TILE)
CPT - 2 (CARPET TILE)
LVT - 1 (LUXURY VINYL TILE)
LVT - 2 (LUXURY VINYL TILE)
AIR TERMINALS, RE MECH
CEILING HEIGHT AFF
REFLECTED CEILING PLAN SYMBOLS LEGEND
LIGHT FIXTURES, RE ELEC
ACT AS SCHEDULED
GWB AS SCHEDULED
OPEN TO STRUCTURE
SPRINKLERS, SEE FIRE
SUPPRESSION DRAWINGS
A. REFER TO GI002 AND A-001 FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
B. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA.
C. EXISTING SEMI-RECESSED STEAM RADIATORS SHALL REMAIN IN PLACE AND
BE CLEANED AND REFURBISHED.
D. EXISTING WINDOWS AND WINDOW SILLS SHALL REMAIN IN PLACE AND BE
CLEANED AND REFURBISHED AS NECESSARY, INCLUDING REPAINTING.
WHERE WINDOW SILLS DO NOT EXIST, SOLID SURFACE SILL SHALL BE
ADDED.
E. WINDOWS SHALL RECEIVE NEW WINDOW TREATMENTS (TRANSLUCENT
SHADES) AT CLASSROOMS.
F. WINDOW TREATMENTS IN ADMINISTRATION OFFICE SHALL REMAIN IN PLACE.
RECONFIGURE WHERE DIRTT WALLS ARE REMOVED OR ADDED.
G. ALL EXTERIOR CORNERS SHALL HAVE FULL HEIGHT CORNER GUARDS AS
SCHEDULED.
H. ALL FURNITURE AND EQUIPMENT SHOWN IS A SUGGESTED LAYOUT AND IS
TO BE PROVIDED BY THE EHRM DEPARTMENT AND VAMC FACILITY AND IS
NOT PART OF THIS CONTRACT. ITEMS THAT ARE MOUNTED, SUCH AS WHITE
BOARDS AND WALL CEILING MOUNTED MONITORS, SHALL HAVE REQUIRED
BLOCKING OR SUPPORTS AND BE INSTALLED BY THE CONTRACTOR.
I. BOTTOM OF EXISTING BEAMS AND SPRINKLER HEADS TO BE FIELD VERIFIED
TO CONFIRM EXACT HEIGHT OF ACOUSTIC CEILING MOUNTING.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
RM 407 & 406
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:3
P
M
AE112
PLANS - 4TH FLOOR - ROOM 406 EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/4" = 1'-0"
FLOOR PLAN - 4TH FLOOR ROOM 406
F7
1. PATCH AND PREP FLOOR FOR NEW FLOOR FINISHES. FLOAT FLOOR.
2. REPAIR AND REPAINT HOLLOW METAL DOOR FRAME. REFINISH THE
CLASSROOM DOORS BOTH SIDES.
3. REPLACE RADIATOR COVER INSTALLED OVER UNIT.
4. PATCH, REPAIR, AND SKIMCOAT ENTIRE PLASTER OR GYPSUM BOARD
WALL FOR NEW INTERIOR FINISH AS APPROVED BY VAMC INTERIOR
DESIGNER.
5. TRANSLUCENT SHADES (2 AT 7'-2" WIDE, VIF).
1/4" = 1'-0"
FLOOR PLAN - EQUIPMENT 4TH FLOOR ROOM 406
C5
1/4" = 1'-0"
FLOOR PLAN - FINISH 4TH FLOOR ROOM 406
F5
1/4" = 1'-0"
RCP - 4TH FLOOR - 406
C7
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 406 - NORTH
B2
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 406 - SOUTH
C2
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 406 - EAST
E1
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 406 - WEST
F1
EQUIPMENT SCHEDULE
JSN DESCRIPTION
ACQ /
INS
A1033 LOCKERS WITH COAT ROD VC
E0042 WORKCENTER, COMPUTER, FREE STANDING, 48 IN VV
F0205 CHAIR, SIDE WITH ARMS VV
F0435 MEDIA STORAGE CABINET VV
F2025 RECYCLING OR TRASH BIN VV
F2105 LECTURN VV
F3050 WHITEBOARD VC
IN0404 SIGN, SECONDARY ROOM IDENTIFICATION VC
M0515 MOBILE CLASSROOM TELEVISION VV
M1801 LAPTOP COMPUTER VV
C C = CONTRACTOR ACQUIRED, CONTRACTOR INSTALLED
V C = VAMC ACQUIRED, CONTRACTOR INSTALLED
V V = VAMC ACQUIRED, VAMC INSTALLED
FF&E PROCUREMENT LEGEND
C
4 5
D
E
AE113E1
B3
F1
C3
EHRM CLASSROOM
F2B
F2B
F2B
F2B
4 53
E5
AE541
TYP
4 5
D
E
AE113E1
B3
F1
C3
EHRM CLASSROOM
M0515
A1033
E0042
M1801
M4705 F0205
A1033F2025
F0435 F3050
F2105
IN0404
F3050
F3050
F3050
F3050
F3050
F3050
F3050
4 5
D
E
EHRM CLASSROOM
6'
F5
AE541
AE541
C3
F7
AE541
AE541
C3
SIM
TYP
4 5
D
E
3'
EQ EQ
EHRM CLASSROOM
8' - 6"
6' - 8"6' - 8"
F3050F3050 F3050
3'
PNT-6 PNT-6
F3050F3050 F3050 F3050 F3050
3'
FINISH LEGEND
NOT IN CONTRACT CPT - 1 (CARPET TILE)
CPT - 2 (CARPET TILE)
LVT - 1 (LUXURY VINYL TILE)
LVT - 2 (LUXURY VINYL TILE)
AIR TERMINALS, RE MECH
CEILING HEIGHT AFF
REFLECTED CEILING PLAN SYMBOLS LEGEND
LIGHT FIXTURES, RE ELEC
ACT AS SCHEDULED
GWB AS SCHEDULED
OPEN TO STRUCTURE
SPRINKLERS, SEE FIRE
SUPPRESSION DRAWINGS
A. REFER TO GI002 AND A-001 FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
B. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA.
C. EXISTING SEMI-RECESSED STEAM RADIATORS SHALL REMAIN IN PLACE AND
BE CLEANED AND REFURBISHED.
D. EXISTING WINDOWS AND WINDOW SILLS SHALL REMAIN IN PLACE AND BE
CLEANED AND REFURBISHED AS NECESSARY, INCLUDING REPAINTING.
WHERE WINDOW SILLS DO NOT EXIST, SOLID SURFACE SILL SHALL BE
ADDED.
E. WINDOWS SHALL RECEIVE NEW WINDOW TREATMENTS (TRANSLUCENT
SHADES) AT CLASSROOMS.
F. WINDOW TREATMENTS IN ADMINISTRATION OFFICE SHALL REMAIN IN PLACE.
RECONFIGURE WHERE DIRTT WALLS ARE REMOVED OR ADDED.
G. ALL EXTERIOR CORNERS SHALL HAVE FULL HEIGHT CORNER GUARDS AS
SCHEDULED.
H. ALL FURNITURE AND EQUIPMENT SHOWN IS A SUGGESTED LAYOUT AND IS
TO BE PROVIDED BY THE EHRM DEPARTMENT AND VAMC FACILITY AND IS
NOT PART OF THIS CONTRACT. ITEMS THAT ARE MOUNTED, SUCH AS WHITE
BOARDS AND WALL CEILING MOUNTED MONITORS, SHALL HAVE REQUIRED
BLOCKING OR SUPPORTS AND BE INSTALLED BY THE CONTRACTOR.
I. BOTTOM OF EXISTING BEAMS AND SPRINKLER HEADS TO BE FIELD VERIFIED
TO CONFIRM EXACT HEIGHT OF ACOUSTIC CEILING MOUNTING.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
RM 407 & 406
P la n N or th
True North
BLDG 02
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
C :\R ev it
\2 3.
_A
R C
H _R
_d jo hn so nQ
P A
E 4.
rv t
2/
/2
8:
:4
P
M
AE113
PLANS - 4TH FLOOR - ROOM 407 EHRM TRAINING AND ADMIN
SUPPORT SPACE - BONHAM, TX
1201 E 9TH ST, BONHAM, TX 75418
549A4-21-703
SH DJ
100% CONSTRUCTION
DOCUMENTS
VEG 23.13
1/4" = 1'-0"
FLOOR PLAN - 4TH FLOOR ROOM 407
F7
1. PATCH AND PREP FLOOR FOR NEW FLOOR FINISHES. FLOAT FLOOR.
2. REPAIR AND REPAINT HOLLOW METAL DOOR FRAME. REFINISH THE
CLASSROOM DOORS BOTH SIDES.
3. REPLACE RADIATOR COVER INSTALLED OVER UNIT.
4. PATCH, REPAIR, AND SKIMCOAT ENTIRE PLASTER OR GYPSUM BOARD
WALL FOR NEW INTERIOR FINISH AS APPROVED BY VAMC INTERIOR
DESIGNER.
5. TRANSLUCENT SHADES (2 AT 7'-2" WIDE, VIF).
1/4" = 1'-0"
FLOOR PLAN - EQUIPMENT 4TH FLOOR ROOM 407
C5
1/4" = 1'-0"
FLOOR PLAN - FINISH 4TH FLOOR ROOM 407
F5
1/4" = 1'-0"
RCP - 4TH FLOOR - 407
C7
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 407 - WEST
F1
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 407 - SOUTH
C3
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 407 - NORTH
B3
3/8" = 1'-0"
INTERIOR ELEVATION - 4TH FLOOR - ROOM 407 - EAST
E1
EQUIPMENT SCHEDULE
JSN DESCRIPTION
ACQ /
INS
A1033 LOCKERS WITH COAT ROD VC
E0042 WORKCENTER, COMPUTER, FREE STANDING, 48 IN VV
F0205 CHAIR, SIDE WITH ARMS VV
F0435 MEDIA STORAGE CABINET VV
F2025 RECYCLING OR TRASH BIN VV
F2105 LECTURN VV
F3050 WHITEBOARD VC
IN0404 SIGN, SECONDARY ROOM IDENTIFICATION VC
M0515 MOBILE CLASSROOM TELEVISION VV
M1801 LAPTOP COMPUTER VV
C C = CONTRACTOR ACQUIRED, CONTRACTOR INSTALLED
V C = VAMC ACQUIRED, CONTRACTOR INSTALLED
V V = VAMC ACQUIRED, VAMC INSTALLED
FF&E PROCUREMENT LEGEND
ALIGN
TC
A
LI
G N
ALIGN
1 2
F
G
AE114
B2
C2
F1 E1
ADMINISTRATION
OFFICE AREA
414B
CONFERENCE
414A
RECEPTION
4A
5 3
4B
C1
AE301
TYP
1 2
F
G
AE114
B2
C2
F1 E1
ADMINISTRATION
OFFICE AREA
414A
RECEPTION
414B
CONFERENCE
F3050
M1840
E0075.3
F0280
F0280
A6105
F0210F0210
F0725
F0820
F0220
F0120F0120
F0420
E0075.3 E0075.3E0075.3
F0420
IN0404
IN0404
1 2
F
G
ADMINISTRATION
OFFICE AREA
414B
CONFERENCE
414A
RECEPTION
CG-1
AE411
F5
F7
AE541
F5
AE541
TYP
B5
AE541
1 2
F
G
EQ EQ
414A
RECEPTION
414B
CONFERENCE
ADMINISTRATION
OFFICE AREA
A5215
8' - 6"
8' - 6"
A6046F3050
PNT-4
3'
PNT-4
PNT-4
F3050
A6046
414A
4'
M1840
FINISH LEGEND
NOT IN CONTRACT CPT - 1 (CARPET TILE)
CPT - 2 (CARPET TILE)
LVT - 1 (LUXURY VINYL TILE)
LVT - 2 (LUXURY VINYL TILE)
AIR TERMINALS, RE MECH
CEILING HEIGHT AFF
REFLECTED CEILING PLAN SYMBOLS LEGEND
LIGHT FIXTURES, RE ELEC
ACT AS SCHEDULED
GWB AS SCHEDULED
OPEN TO STRUCTURE
SPRINKLERS, SEE FIRE
SUPPRESSION DRAWINGS
A. REFER TO GI002 AND A-001 FOR ABBREVIATIONS AND ADDITIONAL SYMOBLS
AND GENERAL NOTES.
B. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT
BARRIER AROUND THE PROJECT AREA CONSISTENT WITH THE
CONTRACTOR'S PHASING PLAN AS APPROVED BY THE VA.
C. EXISTING SEMI-RECESSED STEAM RADIATORS SHALL REMAIN IN PLACE AND
BE CLEANED AND REFURBISHED.
D. EXISTING WINDOWS AND WINDOW SILLS SHALL REMAIN IN PLACE AND BE
CLEANED AND REFURBISHED AS NECESSARY, INCLUDING REPAINTING.
WHERE WINDOW SILLS DO NOT EXIST, SOLID SURFACE SILL SHALL BE
ADDED.
E. WINDOWS SHALL RECEIVE NEW WINDOW TREATMENTS (TRANSLUCENT
SHADES) AT CLASSROOMS.
F. WINDOW TREATMENTS IN ADMINISTRATION OFFICE SHALL REMAIN IN PLACE.
RECONFIGURE WHERE DIRTT WALLS ARE REMOVED OR ADDED.
G. ALL EXTERIOR CORNERS SHALL HAVE FULL HEIGHT CORNER GUARDS AS
SCHEDULED.
H. ALL FURNITURE AND EQUIPMENT SHOWN IS A SUGGESTED LAYOUT AND IS
TO BE PROVIDED BY THE EHRM DEPARTMENT AND VAMC FACILITY AND IS
NOT PART OF THIS CONTRACT. ITEMS THAT ARE MOUNTED, SUCH AS WHITE
BOARDS AND WALL CEILING MOUNTED MONITORS, SHALL HAVE REQUIRED
BLOCKING OR SUPPORTS AND BE INSTALLED BY THE CONTRACTOR.
I. BOTTOM OF EXISTING BEAMS AND SPRINKLER HEADS TO BE FIELD VERIFIED
TO CONFIRM EXACT HEIGHT OF ACOUSTIC CEILING MOUNTING.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .