S02 MRI Site Prep Drawings.pdf
PDF 5 MB Posted
- Attached to
- Z1DA--Construction Project Magnetic Resonance Imaging (MRI) Site Preparation Project Number: 581-20-904
- Solicitation number
- 36C24521B0007
About this file
This document provides details for a federal contract solicitation for construction services. The Department of Veterans Affairs intends to issue an Invitation for Bids to award a single, firm fixed price contract for construction services related to a Magnetic Resonance Imaging site preparation project at the VA Medical Center in Huntington, West Virginia. The project consists of providing all labor, materials, equipment, permits, transportation and supervision necessary for the construction services. The performance period is 195 calendar days from receipt of the notice to proceed. This solicitation is set aside as 100% for Service-Disabled Veteran-Owned Small Businesses. The North American Industry Classification System code is 236220 with a small business size standard of $39.5 million in annual receipts for the past three years. The magnitude of construction is estimated between $500,000 to $1 million.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 N-EAS190354 VA Huntington MRI Final 11-24-20.pdf | ||
| 36C24521B0007 0003.docx | DOCX document | |
| A1-0 - Renovation Plan MRI.pdf | ||
| 071400s0-Shield_Requirements.plt.pdf | ||
| 071400s0-Shield_Design.plt.pdf | ||
| 36C24521B0007 0002.docx | DOCX document | |
| Record of Attendance - Site Visit - 4-12-2021 MRI Site Prep.pdf | ||
| 36C24521B0007 0001.docx | DOCX document | |
| 36C24521B0007_1.docx | DOCX document | |
| S02 MRI Site Prep Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
MRI SITE PREPARATION PROJECT
VAMC HUNTINGTON, WEST VIRGINIA
PROJECT LOCATION:
HERSHEL WOODY WILLIAMS VA MEDICAL CENTER
VA PROJECT NUMBER:
100% CONSTRUCTION DOCUMENTS
581-20-904
1540 SPRING VALLEY DRIVE
HUNTINGTON, WV 25704
1/20/2021
LOCATION MAP AREA MAP
AREA OF WORK
APPLICABLE CODES:
• 2015 INTERNATIONAL BUILDING CODE
• 2009 INTERNATIONAL ENERGY CONSERVATION CODE
• 2015 INTERNATIONAL EXISTING BUILDING CODE
• 2015 INTERNATIONAL FUEL GAS CODE
• 2015 INTERNATIONAL MECHANICAL CODE
• 2015 INTERNATIONAL PLUMBING CODE
C :\U se rs
\a br ad st oc k\
D oc um en ts \V
D C
I_ C en tra l_ M
R I S ite P re p_ ab ra ds to ck ve te ra n-dc i.c om .rv t 1/
/2
1:
:4
PM
G-001
COVER SHEET
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021
DRAWING LIST
GENERAL
G-001 COVER SHEET
ARCHITECTURAL
A-001 LEGENDS, ABBREVIATIONS AND NOTES
AD-101 DEMOLITION PLANS
A-101 FLOOR PLANS
A-401 ELEVATIONS, SECTIONS AND DETAILS
A-501 DETAILS
A-601 SCHEDULES & DIAGRAMS
MECHANICAL
M-001 MECHANICAL SYMBOLS AND ABBREVIATIONS
MD-101 SECOND FLOOR PLAN - MECHANICAL DEMOLITION
M-101 SECOND FLOOR PLAN - MECHANICAL NEW WORK
M-501 DETAILS - MECHANICAL
M-601 MECHANICAL SCHEDULES
PLUMBING
P-001 PLUMBING GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
PD-101 SECOND FLOOR PLAN - PLUMBING DEMOLITION
P-101 SECOND FLOOR PLAN - PLUMBING NEW WORK
ELECTRICAL
E-001 ELECTRICAL SYMBOLS & ABBREVIATIONS
ED-101 SECOND FLOOR PLAN - ELECTRICAL DEMOLITION
E-101 SECOND FLOOR PLAN - ELECTRICAL NEW WORK
E-201 SECOND FLOOR PLAN - LIGHTING
E-501 ELECTRICAL ONE-LINE DIAGRAM & DETAILS
E-601 ELECTRICAL PANEL SCHEDULES
Revisions: Date:
DOOR TAG
REMOVAL KEY NOTE
ANNOTATION SYMBOLS LEGEND:
WALL / PARTITION TYPE TAG
DETAIL ELEVATION
EXTERIOR ELEVATION
CALLOUT LASSO
XXX
DIMENSION STRING
X'-X"
X-XXXX
X-XXX
X
X
X-XXX
X
X-XXX
X
X-XXX
X
X-XXX
X
DETAIL SECTIONBUILDING
SECTION
WALL SECTION
NORTH
NORTH ARROW
1ST FLOOR
100' - 0"
ELEVATION MARKER
DETAIL
NUMBER
SHEET
DETAIL NUMBER
(TYP.)
SHEET (TYP.)
ROOM TAG
ROOM
REVISION IDENTIFICATION
REVISION
REVISION NUMBER
A WINDOW TAG
DOOR (EXISTING)
DOOR
(NEW CONSTRUCTION)
R#
RENOVATION KEY NOTE
EXISTING CONSTRUCTION
(TO BE REMOVED)
XXX
A
WINDOW TAG
WINDOW UNIT
DOOR
DOOR TAG
EXAMPLE:
ø 5
0"
30" MIN.
M
IN
TURNING RADIUS WHEELCHAIR APPROACH
ADA CLEARANCES:
M
IN
MAX.
6"
M
IN
MIN.
11"
MIN.
8"
MAX.
17" - 25"
KNEE & TOE CLEARANCES
3' -2
4" 2'
-5
2' -1
0"
1' -6
2' -5
2' -1
0"
1'-0" 3'-6"
2' -0
1' -5
3' -1
0"
1' -6
"*3 '-0
4' -0
4' -6
1'-6"
6" 3'-0"
1' -7
39"-41"
1' -6
1'-6" 7"-9"
SD TD
CHILD
ADA
UR
LAV
PROVIDE CLEARANCE
OF 1 1/2" MIN. BELOW
GB, 12" MIN ABOVE GB
PROVIDE CLEARANCE FOR
FLUSH VALVE AT GRAB
BARS, TYP.
PROTECTIVE PIPE WRAP OR
ENCLOSURE AT HANDICAPPED
LAVATORY, TYP.
PROTECTIVE PIPE
WRAP OR ENCLOSURE
AT HANDICAPPED
LAVATORY, TYP.
GBX = GRAB BAR; 'X' REPRESENTS LENGTH (E.G. GB36 IS A 36" LONG GRAB BAR.
GBL3052 IS AN L-SHAPED GRAB BAR 30"x52".)
FOR OTHER ACCESSORY ITEMS, SEE MANUFACTURER'S REQUIREMENTS FOR
HANDICAPPED MOUNTING HEIGHTS.
NOTE:
NOTE:
REFER TO PLUMBING DRAWINGS FOR ACTUAL FIXTURE TYPES. FIXTURES DEPICTED ARE
FOR INFORMATIONAL PURPOSES WITH REGARD TO MOUNTING HEIGHTS AND LOCATIONS.
NOTE:
REFER TO WASHROOM INTERIOR ELEVATIONS FOR ACCESSORY MOUNTING LOCATIONS
IN ROOMS.
NOTE:
UR
TYPICAL MOUNTING HEIGHTS AND LOCATIONS:
T O
E N
S U
R E
M A
X
GB36
WC
TPHLAV
TD MAX.
MAX.
GB42
F O
R W
A R
D R
E A
C H
DF/WBF
MIRR
GB18
WC
TPH
LAV
1'
5"
(C H
IL
D
R E
N
WR
M A
X
M A
X 18
(C H
IL
D
R E
N
(C H
IL
D
R E
N
34"-36"
(CHILDREN)
(C H
IL
D
R E
N
2' -7
(C H
IL
D
R E
N
A G
E
-1 2)
(C H
IL
D
2' -1
0"
(C H
IL
D
R
N
E S
-1
2)
CHILDREN'S REACH RANGES (SUGGESTED)
FORWARD OR
SIDE REACH
AGES
3 AND 4
AGES
5 - 8
AGES
9 - 12
HIGH (MAX)
LOW (MIN)
36"
20"
40"
18"
44"
16"
COORDINATE MOUNTING HEIGHTS OF FIXTURES AND EQUIPMENT WITH SUGGESTED
CHILDREN'S REACH RANGES CHART PER ADVISORY 308.1 REACH RANGES FROM THE U.S.
ACCESS BOARD FOR ANSI 117.1-2009.
NOTE:
S T
A N
D
IN
P
R S
O N
S
M A
X
W H
E E
LC
H
IR
C C
E S
S
IB
LE
M A
X
C H
IL
D
R E
N
M
IN
K N
E E
C
LE
A R
5'
0' M
A X
FE
F E
LB
S
3'
6" M
A X
F E
LB
S
FEC
MOUNT CABINET SUCH
THAT FIRE EXTINGUISHER
HEIGHT IS MAINTAINED.
DOOR FRAME
18"
MIN.
SN
M
IN
M
A X
B T
M
O F
B R
A
IL
LE
SD -
TD -
WR -
UR -
LAV -
MIRR -
WC -
GB -
TPH -
DF/WBF -
FE -
FEC -
SN -
SOAP DISPENSER
TOWEL DISPENSER
WASTE RECEPTACLE
URINAL
LAVATORY
MIRROR
WATER CLOSET
GRAB BAR
TOILET PAPER HOLDER
DRINKING FOUNTAIN / WATER BOTTLE FILLER
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
SIGN
HATCH LEGEND
CONCRETE
(CAST IN PLACE OR PRECAST)
GYPSUM WALL BOARD
CONCRETE MASONRY
EARTH
RIGID INSULATION
BATT INSULATION
WOOD / LUMBER
PLYWOOD
STEEL
UNDERBED MATERIAL
BRICK
A
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
@ AT
B
BLKG BLOCKING
C
CAB CABINET
CCT CUBICLE CURTAIN TRACK
CG CORNER WALL GUARD
CLG CEILING
CLO CLOSET
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CSS CLINICAL SERVICE SINK
CPT CARPET
CT CERAMIC TILE
D
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DR DOOR
DIG DRAWING
DWR DRAWER
E
EA EACH
EG END WALL GUARD
ELEC ELECTRIC(AL)
ELEV ELEVATOR/ ELEVATION
EMER EMERGENCY
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FT FEET/ FOOT
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHS FIRE HOSE STATION (CABINET)
FHV FIRE HOSE VALVE CABINET
FLR FLOOR(ING)
FLUOR FLUORESCENT
FR FRAME
FVC FIRE VALVE CABINET
G
GALV GALVANIZE(D)
GB GRAB BAR
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GWB GYPSUM WALL BOARD
H
HC HOLLOWCORE
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
I
IB INTEGRAL BASE
ID INSIDE DIAMETER
IN INCH(ES)
INT INTERIOR
INTEG INTEGRAL
INTLK INTERLOCK
L
LAM LAMINATE(D)
LAV LAVATORY
LB POUND
LT LENGTH
LH LEFT HAND
LHRB LEFT HAND REVERSE BEVEL
LOCK LOCKERS
LVR LOUVER
M
MA MEDICAL AIR
MAX MAXIMUM
MED MEDICAL/MEDICATIONS
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N
N NORTH/ NITROGEN
NC NURSE CALL
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
O/OX OXYGEN
OPG OPENING
P
PL PLATE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PR PAIR
PNT PAINT(ED)
PRT PARTITION
R
RB RESILIENT BASE
REQ REQUIRED
RESIL RESILIENT
REV REVISED
RH RIGHT HAND
RHRB RIGHT HAND REVERSE BEVEL
RO ROUGH OPENING
S
S SOUTH
SCW SOLID CORE WOOD
SEAL SEALANT
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SSM SOLID SURFACE MATERIAL
SS STAINLESS STEEL
SSV SEAMLESS SHEET VINYL
STL STEEL
STN STAIN
STOR STORAGE
STRUCT STRUCTURAL
SV SHEET VINYL
T
TC TERRA COTTA
TEL TELEPHONE
TEMP TEMPORARY
THK THICK(NESS)
TOC TOP OF CURB
TOIL TOILET
TOS TOP OF SLAB/ TOP OF STEEL
TPTN TOILET PARTITION
TV TELEVISION
TW TOP OF WALL
TYP TYPICAL
TZ TERRAZZO
U
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
V
VAC VACUUM
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
W
W WEST
W/ WITH
WC WATER CLOSET/
WATER COOLER/
WALL COVERING
WD WOOD
WG WIRE GLASS
WH WALL HUNG
W/O WITHOUT
WP WATERPROOF(ING)
WR WATER RESISTANT
WS WEATHERSTRIPPING
WSCT WAINSCOT
WT WEIGHT
ABBREVIATIONS
EXISTING ITEM(S) / EQUIPMENT TO BE PROVIDED
EXISTING ITEM(S) / EQUIPMENT TO REMAIN
RENOVATION LINE TYPE LEGEND
EXISTING ITEM(S) / EQUIPMENT TO BE REMOVED
EXISTING ITEM(S) / EQUIPMENT TO REMAIN
REMOVAL LINE TYPE LEGEND
EXISTING TO REMAIN
LINE TYPE LEGEND - ROOF
ROOF SYSTEM, FLASHING, EQUIPMENT, ITEMS
TO BE PROVIDED
CHANGE IN ELEVATION MARKER
(HIGH/LOW)
ROOF SYSTEM, FLASHING, EQUIPMENT, ITEMS
TO BE REMOVED
2 HR FIRE SEPARATION
1 HR FIRE SEPARATION
SMOKE BARRIER
PRIMARY EGRESS PATH
ROOF
FILE STORAGE
2B166f
MRI CONTROL
2B166d
MRI SCAN
2B166a
MRI EQUIP RM
2B166b
CORR.
C2-12
CORR.
C2-10
CORR.
C2-14
CORR.
C2-13
CORR.
C2-42
CORR.
C2-19
CORR.
C2-9
CORR.
C2-11
CORR.
C2-8
IMAGING
NUCLEAR
MEDICINE
MECH
2B155
ELEC. CLOSET
2B166e
DRESS
2B166c
STAIR 4
SERVICE LOBBY C2-16
STAIR 2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n
M R
I R e p la c e m e n t_
V
L
A rr ia z a
.r v t
/1
/2
:4
:3
P
M
A001
LEGENDS, ABBREVIATIONS AND
NOTES
SCALE: 1/16" = 1'-0"A001
1 SECOND FLOOR PLAN LIFE SAFETY
Revisions: Date:
LArriaza
EJL
FP
DUNNAGE
DUNNAGE
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
FILE STORAGE
2B166f
MRI EQUIP. RM
2B166b
CORR.
C2-12
CORR.
C2-10
ELEC. CLOSET
2B166e
N O
T E
/2
CURB
CURB
MEDICAL GAS
CONTROLS
ROOF
178"
DRESS
2B166c
MEDICAL GAS
OUTLET
8' - 9"
8' - 6"
8' - 3 1/2"
CORR.
C2-10
MRI SCAN ROOM
2B166a
CORR.
C2-12
ELEC. CLOSET
2B166e
MRI CONTROL
2B166d
MRI EQUIP. RM
2B166b
7' - 11"
19 20
EXPANSION
JOINT
CONFERENCE
ISOCENTER
OFFICE
OFFICEOFFICE OFFICE
OFFICE
ISOCENTER
5 1/2"
DROP,TYP.
± 15' - 0"
EXPANSION
JOINT
5 1/2"
DROP,TYP.
ISOCENTER
2'
± 10' - 0" ± 10' -0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n M
R I R e p la c e m e n t_
V e lo re n z G
W
H R
.r v t
/2
/2
:0
:1
A
M
AD101
DEMOLITION PLANS
SCALE: 1/8" = 1'-0"AD101
1 SECOND FLOOR PLAN DEMO
GENERAL REMOVAL NOTES
A. ITEMS DESIGNATED ON PLAN BY DASHED LINE ARE EXISTING ELEMENTS TO BE
REMOVED. SEE OTHER TRADE DRAWINGS FOR OTHER REMOVALS, INCLUDING
MODIFICATIONS THAT MAY EXTEND BEYOND AREAS SHOWN.
B. FOR DURATION OF PROJECT, PROTECT EXISTING CONSTRUCTION AND/OR EQUIPMENT
TO REMAIN FROM DAMAGE OR CONSTRUCTION ACTIVITIES. WHERE CONSTRUCTION
ACTIVITIES RESULT IN DAMAGE TO EXISTING CONSTRUCTION TO BE RETAINED,
REPLACE/REPAIR EXISTING CONSTRUCTION TO RETURN IT TO ITS ORIGINAL
CONDITION. WHERE REMOVAL OF EXISTING CONSTRUCTION, PIPING, DUCTWORK, AND
OTHER ITEMS CREATES OPENINGS IN WALLS, FLOORS OR CEILINGS, PATCH OPENINGS
IMMEDIATELY WITH SAME MATERIALS AS ADJACENT CONSTRUCTION AND/OR TO
MAINTAIN REQUIRED FIRE RATING.
C. PROVIDE FULL HEIGHT TEMPORARY CONSTRUCTION BARRIERS WHERE REQUIRED TO
PREVENT DUST POLLUTION OF SURROUNDING OCCUPIED AREAS. SEAL AIR-TIGHT.
PARTITIONS MUST BE INSTALLED IN ACCORDANCE WITH FIRE PROTECTION AND
EGRESS REQUIREMENTS. MAINTAIN MEANS OF EGRESS ACCESS TO EXITS DURING
CONSTRUCTION.
D. CONTRACTOR SHALL TAKE PROPER MEASURES TO PREVENT DUST MIGRATION TO
AREAS OUTSIDE THE CONSTRUCTION AREA BY CLOSING ALL OPENINGS IN DUCTS,
WALLS, FLOORS AND CEILINGS. PROVIDE CONTINUOUS EXHAUST TO EXTERIOR TO
MAINTAIN NEGATIVE PRESSURE IN CONSTRUCTION AREA.
E. COORDINATE WITH OWNER FOR EQUIPMENT TO BE SALVAGED AND RETURNED TO
OWNER. THE OWNER WILL RETAIN ALL SALVAGE THAT IS OF VALUE AS DESIGNATED BY
THE USER OR BUILDING ENGINEER. THE CONTRACTOR SHALL REMOVE FROM THE
BUILDING AND DISPOSE OF ALL DEBRIS AND/OR ITEMS NOT RETAINED BY OWNER.
F. INSTALL ADHESIVE MATS INSIDE AND OUTSIDE EACH ACCESS DOOR TO
CONSTRUCTION AREA.
G. REFER TO OTHER TRADE DRAWINGS FOR REMOVAL OF MECHANICAL EQUIPMENT,
DUCTWORK, PIPING, AND ELECTRICAL DEVICES.
H. PRIOR TO DEMOLITION, PERFORM RF SHIELD REPORT TEST. REPORT SHALL CONFIRM
PRESENCE AND EXTENT OF SHIELDING, SPECIFICATION OF SHIELDING AND NOTE ANY
DEFICIENCIES.
I. ALL WORK THAT TRANSMITS VIBRATIONS MUST BE COMPLETED OUTSIDE THE
MEDICAL CENTER'S NORMAL BUSINESS HOURS.
J. USE OF CRANE SHALL BE SHALL BE LIMITED WEEKEND WORK ONLY.
DEMOLITION NOTES
1 REMOVE PORTION OF EXTERIOR PARTITION ASSEMBLY TO FACILITATE THE
REMOVAL OF MRI EQUIP
2 REMOVE EQUIPMENT COVER
3 REMOVE PORTION OF INTERIOR PARTITION ASSEMBLY TO FACILITATE THE
REMOVAL OF MRI EQUIP.
4 REMOVE ACOUSTICAL CEILING PANELS & GRID SYSTEM IN ROOM. REMOVE LIGHT
FIXTURES, DIFFUSERS & OTHER CEILING DEVICES AS REQUIRED. PREPARE TO
RECEIVE NEW CEILING GRID & ACOUSTICAL CEILING PANELS. SEE MEP.
5 REMOVE WALL BASE, FLOOR FINISH, SUBFLOOR DOWN TO EXISTING SLEEPERS.
RETAIN EXISTING SLEEPERS. RETAIN EXISTING SHIELDING. GC TO VERIFY AND
CONFIRM SPECIFICATION OF SHIELDING
6 REMOVE CEILING PANELS, GRID LIGHT FIXTURES, DIFFUSERS AND CEILING
DEVICES TO REMAIN. REMOVE AS NECESSARY TO FACILITATE REMOVAL &
INSTALLATION OF MECHANICAL & ELECTRICAL
8 REMOVE MRI EQUIPMENT
9 REMOVE FLOOR FINISH
10 10.A - IF THE RF SHIELDING TEST REPORT VALIDATES THE PRESENCE OF
SHIELDING THAT MEETS THE PROJECT REQUIREMENTS, RETAIN EXISTING
GYPSUM IN PLACE.
10.B - IF THE RF SHIELDING TEST REPORT INDICATES ABSENCE OR DEFICIENCY IN
SHIELDING, REMOVE GYPSUM BOARD IN IT
11 REMOVE THRESHOLD RAMP
12 REMOVE BASE AND WALL CABINETS TO FACILITATE REMOVAL OF GYP. BD FOR
SHIELDING VERIFICATION. REMOVE AS NECESSARY FOR THE
REMOVAL/INSTALLATION OF THE FLOOR FINISH. RETAIN MILLWORK FOR RE
INSTALLATION
13 MILLWORK TO REMAIN. REMOVE AS NECESSARY FOR INSTALLATION OF FINISHES.
REINSTALL MILLWORK
14 REMOVE WORKSTATION AS NECESSARY FOR INSTALLATION OF MRI CONTROLS &
FINISHES
15 SHIELDING WINDOW ASSEMBLY TO REMAIN
16 CONTROL ROOM SHIELDING WINDOW ASSEMBLY TO REMAIN
17 REMOVE DOOR TO FACILITATE REFINISH. RETAIN HARDWARE FOR REUSE.
REINSTALL DOOR & HARDWARE
18 REMOVE EXISTING SHIELD DOOR, DOOR FRAME AND ACCESSORIES. PREPARE
OPENING TO RECEIVE NEW SHIELDED DOOR AND DOOR FRAME.
19 REMOVE LIGHT FIXTURES, DIFFUSERS AND OTHER CEILING DEVICES AS
REQUIRED IN THIS AREA TO FACILITATE THE INSTALLATION OF STEEL PLATES.
20 REMOVE EXISTING ABOVE CEILING MECHANICAL UNITS, DUCT WORK, AND PIPING,
ELECTRICAL DEVICES, ELECTRICAL AND CONDUITS. REMOVE SHIELDING AND
ASSOCIATED FRAMING TO FACILITATE THE INSTALLATION OF STEEL PLATES.
21 REMOVE CEILING PANELS, CLEAN PANELS & REINSTALL. CLEAN EXISTING GRID
LIGHT FIXTURES, DIFFUSERS AND CEILING DEVICES TO REMAIN.
22 TEMPORARILY REMOVE LIGHT FIXTURES, DIFFUSERS AND OTHER CEILING
DEVICES AS REQUIRED IN THIS AREA TO FACILITATE THE INSTALLATION OF STEEL
PLATES. REMOVE EXISTING ABOVE CEILING MECHANICAL UNITS, DUCT WORK,
AND PIPING, ELECTRICAL DEVICES, ELECTRICAL AND CONDUITS.
23 23.A - IF THE RF SHIELDING TEST REPORT VALIDATES THE PRESENCE OF
SHIELDING THAT MEETS THE PROJECT REQUIREMENTS, RETAIN EXISTING.
23.B - IF THE RF SHIELDING TEST REPORT INDICATES ABSENCE OR DEFICIENCY IN
SHIELDING, REMOVE GYPSUM BOARD IN ITS ENTIRETY DOWN TO EXISTING
FRAMING. RETAIN FRAMING. VERIFY AND PROVIDE WRITTEN CONFIRMATION OF
SHIELDING. SUPPLEMENT/AUGMENT AND INSTALL NEW SHIELDING TO MEET
PROJECT REQUIREMENTS.
24 REMOVE EXISTING SHIELD DOOR, DOOR FRAME AND ACCESSORIES. PREPARE
OPENING TO RECEIVE NEW SHIELDED DOOR AND DOOR FRAME.
SCALE: 1/8" = 1'-0"AD101
2 RCP SECOND FLOOR PLAN DEMO
NOTE: EXPLORATORY HOLES ARE TO CONFIRM THE PRESENCES OF SHIELDING, PATCH TO MATCH EXISTING. IF SHIELDING
DOES NOT, REMOVE ALL PARTITIONS DOWN TO SHIELDING AND INSTALL NEW.
SCALE: 1/8" = 1'-0"AD101
4 RCP FIRST FLOOR PLAN DEMO
Revisions: Date:
SCALE: 1/8" = 1'-0"AD101
3 RCP SECOND FLOOR SLAB ABOVE, DEMO (THIRD FLOOR SLAB)
SCALE: 1/8" = 1'-0"AD101
5 RCP FIRST FLOOR SLAB ABOVE, DEMO (SECOND FLOOR SLAB)
FP
DUNNAGE
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
FILE STORAGE
2B166f
MRI EQUIP. RM
2B166b
CORR.
C2-12
CORR.
C2-10
ELEC. CLOSET
2B166e
CURB
CURB
MEDICAL GAS
CONTROLS
DRESS
2B166c
8"
11' - 0" MEDICAL GAS
OUTLET
ISOCENTER
RAMP
UP +/- 2"
8' - 9" 7' - 11"
CORR.
C2-10
MRI SCAN ROOM
2B166a
CORR.
C2-12
ELEC. CLOSET
2B166e
MRI CONTROL
2B166d
MRI EQUIP. RM
2B166b
8' - 2 5/8"
8' - 6"
8' - 3 1/2"
7' - 11"7' - 11"
7' - 11"
ISOCENTER
FP
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
FILE STORAGE
2B166f
MRI EQUIP. RM
2B166b
CORR.
C2-12
CORR.
C2-10
ELEC. CLOSET
2B166e
DRESS
2B166c8"
FINISH
DIRECTION
F
IN
IS
H
D
IR
E
C T
IO
N
MEDICAL GAS
OUTLET
ISOCENTER
NOTE: REFER TO A601 FOR FINISH SCHEDULE SEEMLESS SHEET FLOORING
RAMP
UP +/- 2"
0"
+/-2" RAISED FLOOR
0"
FP
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
FILE STORAGE
2B166f
MRI EQUIP. RM
2B166b
ELEC. CLOSET
2B166e
DRESS
2B166c
5 6
7 8 9 10 11
12 13
CORR.
C2-10
CORR.
C2-12
8"
24 25
MEDICAL GAS
OUTLET
UP
ISOCENTER
EXPANSION JOINT
CONFERENCE
ISOCENTER
7 7
OFFICE
OFFICE
OFFICE OFFICE
26' - 0"
EXPANSION
JOINT
ISOCENTER
TYP.
A501
5 1/2"
DROP,TYP.
± 13' - 7 1/2"
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
OFFICE
ISOCENTER
5 1/2"
DROP,TYP.
TYP.
A501
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n M
R I R e p la c e m e n t_
V e lo re n z G
W
H R
.r v t
/2
/2
:0
:1
A
M
A101
FLOOR PLANS
SCALE: 1/8" = 1'-0"A101
1 SECOND FLOOR PLAN NEW WORK
GENERAL ARCHITECTURAL NOTES
A. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
NOTIFY THE ARCHITECT OF DISCREPANCIES PRIOR TO COMMENCING WORK. EXISTING
CONDITIONS THAT WOULD EFFECT THE EXECUTION OF THE WORK SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCING THE WORK.
B. ALL DIMENSIONS GIVEN ON PLANS ARE FROM FINISHED FACE TO FINISHED FACE
UNLESS OTHERWISE NOTED. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE
APPROVAL OF THE ARCHITECT UNLESS NOTED.
C. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS AS REQUIRED TO
SUPPORT WALL MOUNTED ITEMS. LOCATE EQUIPMENT AND COORDINATE BLOCKING
LOCATIONS IN FIELD.
D. GENERAL CONTRACTOR SHALL PROVIDE PROTECTION OF EXISTING FINISHES AND/OR
MATERIALS. RESTORE TO ORIGINAL CONDITIONS ANY AREAS OR FINISHES DAMAGED
BY THE WORK, AT THE EXPENSE OF THE CONTRACTOR. REMOVE MEANS OF
PROTECTION AT THE END OF THE PROJECT.
E. ALL SCRATCHES, DENTS, CRACKS, HOLES, OPENINGS, IRREGULARITIES AND/OR
DEFECTS IN BOTH EXISTING AND NEW CONSTRUCTION SURFACES ARE TO BE
PATCHED TO PROVIDE A UNIFORM AND SMOOTH FINISHED SURFACE. CLEAN AND
SAND SMOOTH ALL SURFACES BEFORE APPLYING FINISH MATERIALS.
F. REMOVE ALL EXCESS BUILD-UP OF EXISTING AND/OR NEW WALL AND PAINT
MATERIALS FROM ALL NEW AND EXISTING WALL SURFACES. CLEAN AND FINISH SAND
SMOOTH TO PROVIDE A UNIFORM AND SMOOTH WALL SURFACE READY FOR THE
APPLICATION OF FINISH MATERIALS.
G. DIMENSIONS LOCATING DOORS OR INTERIOR WINDOWS ARE TO OUTSIDE EDGE OF
FRAME UNLESS NOTED OTHERWISE. REFER TO DOOR & WINDOW SHEETS FOR FRAME
TYPE, SIZE AND DETAILS.
H. REFER TO CIVIL, STRUCTURAL, FIRE PROTECTION, MECHANICAL, PLUMBING AND
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
I. ALL WORK THAT TRANSMITS VIBRATIONS MUST BE COMPLETED OUTSIDE THE
MEDICAL CENTER'S NORMAL BUSINESS HOURS.
J. USE OF CRANE SHALL BE LIMITED WEEKEND WORK ONLY.
KEYED NOTES
1 INSTALL EXTERIOR WALL INFILL ASSEMBLY
2 INSTALL REMOVABLE INTERIOR PARTITION ASSEMBLY
3 INSTALL CEILING PANELS & GRID ASSEMBLY
4 INSTALL THRESHOLD RAMP
5 INSTALL FLOOR FINISH ASSEMBLY OVER SLEEPERS
6 INSTALL MRI DEVICE AND ASSOCIATE EQUIPMENT
7 CLEAN EXISTING CEILING PANELS & REINSTALL. CLEAN EXISTING LIGHT
FIXTURES, DIFFUSERS & CEILING DEVICES.
SCALE: 1/8" = 1'-0"A101
2 RCP SECOND FLOOR PLAN NEW WORK
SCALE: 1/8" = 1'-0"A101
4 SECOND FLOOR FINISH PLAN
SCALE: 1/8" = 1'-0"A101
5 SECOND FLOOR EQUIPMENT PLAN
Revisions: Date:
SCALE: 1/8" = 1'-0"A101
6 RCP FIRST FLOOR PLAN NEW WORK
SCALE: 1/8" = 1'-0"A101
7 RCP FIRST FLOOR SLAB ABOVE NEW WORK (SECOND FLOOR SLAB)
SCALE: 1/8" = 1'-0"A101
3 RCP SECOND FLOOR SLAB ABOVE (THIRD FLOOR SLAB)
NOTE: REFER TO A601 FOR EQUIPMENT SCHEDULE
A401
Sim
EIFS INFILL PANEL
DUNNAGE
REMOVE BRICK UP
TO RELIEVING
ANGLE
ASSUMED CONTINUOUS
RELIEVING ANGLE,
EXISTING.
6" METAL STUD @ 16"
O.C. 600S162-43 [33]
SHIELDING
2x4 WOOD STUD @ 16" O.C.
5/8" GYPSUM BOARD
5/8" EXTERIOR SHEATHING
FINISH COAT
MESH
BASE COAT
AIR/WATER
RESISTANT BARRIER
EPS INSULATION
BOARD
FLASHING
FLASHING
EXISTING
BRICK VENEER
ASSEMBLY
ASSUMED CONTINUOUS
RELIEVING ANGLE,
EXISTING.
EXISTING
ROOF SYSTEM
ALIGN SHIELDED PARTITION
WITH ADJACENT SHIELDING
PARTITION
2 x 4 TOP PLATE
CASE BEAD
OVERLAP NEW AND
EXISTING SHIELDING AT
INFILL AT ALL SIDES OF
OPENING
EXISTING SHIELDING,
PRESUMED. GC SHALL
VALIDATE AND CONFIRM
WITH SHIELDING TEST.
COPPER SHEET LAMINATED TO 1/8"
THICK MDF PANELS
EXIST. CONCRETE SLAB
SHIELDING ASSEMBLY
7/8" PLYWOOD SLEEPERS @ 12" O.C.
FINISHED FLOOR
7/8" PLYWOOD SUBFLOOR
OVERLAP NEW AND EXISTING SHIELDING AT
INFILL AT ALL SIDES OF OPENING
EXISTING SHIELDING, PRESUMED. GC SHALL
VALIDATE AND CONFIRM WITH SHIELDING TEST.
BATT INSULATION R-21
ANCHOR TRACKS TO EX. STRUCTURE
WITH POWERED- ACTUATED
FASTENERS @ 12" O.C.
PROVIDE DEFLECTION TOP
TRACK FOR METAL STUDS
V .I.
F
CEILING AS SCHEDULED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n
M R
I R e p la c e m e n t_
V
L
A rr ia z a
.r v t
/1
/2
:4
:4
P
M
A401
ELEVATIONS, SECTIONS &
DETAILS
SCALE: 1/4" = 1'-0"A401
1 WEST ELEVATION NEW WORK
SCALE: 1 1/2" = 1'-0"A401
2 EXTERIOR WALL DETAIL
Revisions: Date:
VARIES
SEE PHILIPS
EXIST. CONCRETE SLAB
SHIELDING ASSEMBLY
7/8" PLYWOOD SLEEPERS @ 12" O.C.
RECESSED FLOOR RACEWAY
1/4" LAUAN
7/8" PLYWOOD SUBFLOOR
FLOOR RACEWAY COVER PLATE
FLOOR FINISH
FLUSH
VARIES
SEE PHILIPS
EXIST. CONCRETE SLAB
SHIELDING ASSEMBLY
7/8" PLYWOOD SLEEPERS @ 12" O.C.
SUPPORT PAD
FINISHED FLOOR
7/8" PLYWOOD SUBFLOOR
1/4" LAUAN
FLUSH
1'
/8
1'
/8
2' - 3 1/4"2' - 3 3/8"
7 7/8"
2' - 3 15/16"
4 3/4"
3' - 4 9/16"
1' - 11 13/16"
IS
O
C E
N T
E R
ISOCENTER
2' - 2 1/16"
1'
/2
1'
/8
2 3/8"
4 3/4"
2 3/8"
5' - 7 3/8"
11 13/16"
7/
8"
THREADED MOUNTING HOLES M10 (4X)
OPENING IN CABLE DUCT COVER
NOTE:
THE FLOOR SURFACE UPON WHICH PHILIPS
EQUIPMENT AND FLOOR PLATES SHALL BE
PLACED/ANCHORED SHALL BE SUPER FLAT
LEVER TO WITHIN + / 1/8"
OPENING IN
CABLE
DUCT
COVER
A501
A501
TYP.
TYP.
IS
O
C E
N T
E R
MRI SCAN ROOM
2B166a
RAM
P
ISOCENTER
11' - 0"
8'
ISOCENTER
S2 S2
S1
S4
MOUNTING PADS TYP.
TYP.
A501
6'
/4
E Q
E Q
14' - 9 3/16"
EQ EQ
2 MM THICK STEEL PLATE
PLATE TO BE POSITIONED
IN BETWEEN PARENT AND
RF WALL
ISOCENTER
MRI EQUIPMENT
BELOW
A501
Sim
3/8" dia x 2 1/2" TITEN
SCREWS (SIMPSON STRONG
TIE OR EQUAL) @ 3'-0" O.C.
3'
/2
6'
/2
7' - 4 5/8" 7' - 4 5/8"
14' - 9 3/16" 10' - 7 15/16" 10' - 7 15/16"
6'
/4
6'
/4
3'
/8
3'
/8 " 6'
/4
21' - 3 7/8"
/2
6 MM THICK STEEL
PLATE
4 MM THICK STEEL
PLATE
ISOCENTER
MRI EQUIPMENT
ABOVE
A501
Sim
3/8" dia x 2 1/2" TITEN
SCREWS (SIMPSON STRONG
TIE OR EQUAL) @ 3'-0" O.C.
3/8" dia x 2 1/2" TITEN
SCREWS (SIMPSON STRONG
TIE OR EQUAL) @ 3'-0" O.C.
14' - 9 3/16"
4'
/1 6"
6'
/2
7' - 4 5/8" 7' - 4 5/8"
14' - 9 3/16"
6' - 6 3/4"
10' - 7 15/16"10' - 7 15/16"
6' - 6 3/4"
13' - 1 1/2"
3'
/2
/8
21' - 3 7/8"
6 MM THICK STEEL
PLATE
4 MM THICK STEEL
PLATE
M
M .
M
M .
M
M
6 MM THICK STEEL PLATE
4 MM THICK STEEL PLATE
PLATE SPECIFICATIONS:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n M
R I R e p la c e m e n t_
V e lo re n z G
W
H R
.r v t
/2
/2
:0
:1
A
M
A501
DETAILS
SCALE: 3" = 1'-0"A501
2 RAISED FLOOR SYSTEM WITH RACEWAY
SCALE: 3" = 1'-0"A501
3 RAISED FLOOR SYSTEM WITH SUPPORT PAD
SCALE: 1/2" = 1'-0"A501
5 MAGNET AND PATIENT SUPPORT DETAIL
SCALE: 1/4" = 1'-0"A501
1 SECOND FLOOR PLAN NEW WORK MRI SUPPORT LAYOUT
SCALE: 1/4" = 1'-0"A501
6 CEILING PLATE DETAIL (PLAN VIEW)
SCALE: 1/4" = 1'-0"A501
7 CEILING PLATE DETAIL
SCALE: 1/4" = 1'-0"A501
8 BOTTOM PLATES DETAIL (PLAN VIEW)
SCALE: 1/4" = 1'-0"A501
9 BOTTOM PLATES DETAIL
SCALE: N.T.S.A501
4 BOTTOM PLATES DETAIL
Revisions: Date:
2"
PARTITION AS
SCHEDULED
METAL STUD LINTEL AS
REQ. FOR SPAN
METAL RUNNER
CHANNEL
SEALANT, TYP.
HOLLOW METAL
FRAME AS
SCHEDULED
DOOR AS SCHEDULED
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC
METAL INSIDE EXAMINATION ROOM.
T Y
P
4" 2"
PARTITION AS SCHEDULED
(2) 25 GA. METAL STUDS
FLOOR TO TOP OF WALL,
BRACE TO STRUCTURE
SEALANT, TYP.
HOLLOW METAL FRAME
(AS SCHEDULED)
DOOR AS SCHEDULED
ADJACEN
T WALL
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC
METAL INSIDE EXAMINATION ROOM.
SEALANT, BOTH
SIDES
TOP OF STRUCTURE
5/8" GYPSUM BOARD, ALL SIDES
3 5/8" METAL
STUD, 16" O.C.
4 7/8"
P
LA
N V
IE
W
S E
C T
IO
N
PARTITION TYPE A PARTIAL HEIGHT WALL
S E
C T
IO
N
CORNER BEAD, TYPICAL
FIRE RESISTANCE RATING = NONE
STC RATING = NONE
NON-RATED PARTITION
EXIST. CEILING
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC METAL INSIDE EXAMINATION ROOM.
A
S E
E S
C H
E D
U
LE
SCHEDULE
SEE
FLUSH MOUNTED DOOR
DOOR TYPE LEGEND
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC
METAL INSIDE EXAMINATION ROOM.
2" 2"
F-1
S E
E S
C H
E D
U
LE
2"
SCHEDULE
SEE
FRAME TYPE LEGEND
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC
METAL INSIDE EXAMINATION ROOM.
FURRING PARTITIONPARTITION TYPE D1
NON-RATED PARTITION
TOP OF FLOOR STRUCTURE
5/8" GYP. BD. (USE
MOISTURE RESISTANT
GYP BD. AT WET
APPLICATION SIDE)
2 x 4 WOOD STUD, 16" O.C.
BOTTOM OF STRUCTURE
CEILING AS SCHEDULED
SILL PLATE
TOP PLATE
4 1/8"
S E
C T
IO
N
P
LA
N V
IE
W
S E
C T
IO
N
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC METAL INSIDE EXAMINATION ROOM.
1/
4"
2' - 4 1/16"
EXISTING FLOOR
THRESHOLD RAMP
PARTITION TYPE C1A
NON-RATED PARTITION
TOP OF FLOOR STRUCTURE
BOTTOM OF STRUCTURE
CEILING AS SCHEDULED
SILL PLATE
TOP PLATE
4 1/8"
S E
C T
IO
N
P
LA
N V
IE
W
S E
C T
IO
N
COPPER SHEET LAMINATED
TO 1/8" THICK MDF PANELS
WOOD BLOCKING
3 5/8" METAL STUD @ 16" O.C.
METAL TRACK
5/8" GYP. BD.
METAL TRACK
COPPER SHEET LAMINATED
TO 1/8" THICK MDF PANELS
WOOD BLOCKING
T-CLIP FOR FASTENING
FRAMING TO SHIELD
SOUND INSULATION
NOTE: ALL METAL SHALL BE NON-FERROMAGNETIC METAL INSIDE EXAMINATION ROOM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ENGINEERS:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
VETERAN DESIGN & CONSTRUCTION INC.
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080 1.20.2021 EJL LAA
F R e v it L o c a ls
\2
.4
.0
V A
M C
H u n ti n g to n
M R
I R e p la c e m e n t_
V
L
A rr ia z a
.r v t
/1
/2
:4
:5
P
M
A601
SCHEDULES & DIAGRAMS
DOOR SCHEDULE
DOOR
NUMBER
TO ROOM: NAME
FIRE
RATING
DOOR FRAME
GLASS
DETAILS
HARDWARE
GROUP
COMMENTSDOOR
TYPE
OPENING SIZE
THICKNESS DOOR MATERIAL DOOR FINISH
FRAME
TYPE
FRAME MATERIAL FRAME FINISH HEAD JAMB THRESHOLD
HEIGHT WIDTH
1 MRI SCAN ROOM - - 7' - 0" 4' - 0" 1 3/4" SCW STN 1 A *HM PNT - 3/A601 4/A601 7/A601 1 RF SHIELDED DOOR & FRAME
2 MRI CONTROL 20 MIN - 7' - 0" 4' - 0" 1 3/4" ETR STN 1 ETR ETR ETR - ETR ETR ETR ETR
3 MRI CONTROL - - 7' - 0" 3' - 0" 1 3/4" ETR STN 1 ETR ETR ETR - ETR ETR ETR ETR
4 MRI EQUIP. RM ETR ETR 7' - 0" 3' - 0" 1 3/4" ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
5 ELEC. CLOSET ETR ETR 7' - 0" 6' - 8" 1 3/4" ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
6 ELEC. CLOSET ETR ETR 7' - 0" 3' - 0" 1 3/4" ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
7 CORR. ETR ETR 7' - 0" 3' - 9" 1 3/4" ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
SCALE: 1 1/2" = 1'-0"A601
3 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A601
4 JAMB DETAIL
SCALE: 1" = 1'-0"A601
5 PARTITION TYPES
EQUIPMENT SCHEDULE
MARK EQUIPMENT NAME EQUIPMENT NUMBER
FURNISH /
INSTALL
1 GRADIENT AMPLIFIER 787 DOUBLE CABINET GAC MFMI
2 BACKUP POWER CONNECTION PANEL BCP FUTURE
3 SERVICE PLATFORM SP MFMI
4 KKT CHILLER INTERFACE PANEL CIP MFCI
5 LIQUID COOLING CABINET LCC MFCI
6 AIR COOLED CRYO-COOLER ACCC MFCI
7 60Hz TRANSFORMER CABINET TC MFCI
8 MAINS DISTRIBUTION UNIT MDU MFCI
9 FA SERIES THREE PHASE FILTER FAF MFCI
10 CIRCUIT BREAKER (for UPS) CBU CFCI
11 CIRCUIT BREAKER (for System) CBS CFCI
12 50 kVA UPS CABINET UPS MFMI
13 BATTERY CABINET BC MFMI
14 OPERATOR'S TABLE OT MFMI
15 FLEX CADDY COIL CART FC MFMI
18 SYSTEM FILTER BOX WITH COVERS SFB MFMI
19 DATA ACQUISITION AND CONTROL CABINET DACC MFMI
20 KKT CHILLER REMOTE CONTROLLER RDP MFCI
21 E-ALERT EA MFMI
22 SYSTEM AIR COOLING UNIT SACU MFMI
23 REMOTE STATUS PANEL RSP OPTIONAL
24 EMERGENCY RUN-DOWN BUTTON ERB MFCI
25 EMERGENCY RUN-DOWN BUTTON ERB MFCI
26 MULTI-CAMERA MC CFCI
27 HA FLEX TRAK FT MFMI
28 STORAGE RAIL SR MFMI
29 LCD MONITOR LM MFCI
30 PCI PATIENT CAMERA INTERFACE ASSY PCI MFCI
31 MAGNET ASSEMBLY MAG MFCI
SCALE: 1/4" = 1'-0"A601
1 DOOR TYPE LEGEND
SCALE: 1/4" = 1'-0"A601
2 FRAME TYPE LEGEND
SCALE: 1" = 1'-0"A601
7 PARTION TYPES
SCALE: 3" = 1'-0"A601
8 FLUSH THRESHOLD RAMP ASSEMBLY
SCALE: 1" = 1'-0"A601
6 PARTION TYPES
NOTE: * ALL METAL SHALL BE NON-FERROMAGNETIC METAL INSIDE EXAMINATION ROOM.
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM NAME
FLOOR
BASE
WALLS CEILING
COMMENTS
FINISH
NORTH SOUTH EAST WEST
MATERIAL FINISH
MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
- CONFERENCE ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR * ACP-1 - * REINSTALL EXISTING (FIRST FLOOR)
- ADJACENT OFFICE (FIRST FLOOR) ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ACP-E
2B166a MRI SCAN ROOM LVT-1 RB-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 ACP-1 ACP-1
2B166b MRI EQUIP. RM ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
2B166c DRESS LVT-1 RB-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 * ACP-1 - * REINSTALL EXISTING
2B166d MRI CONTROL LVT-1 RB-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 GYP PNT-1 * ACP-1 - * REINSTALL EXISTING
2B166e ELEC. CLOSET ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
2B166f FILE STORAGE ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
C2-10 CORR. ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
C2-12 CORR. ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR
FURNISH / INSTALL KEY
MFMI - MANUFACTURE FURNISHED, MANUFACTURE INSTALLED
MFCI - MANUFACTURE FURNISHED, CONTRACTOR INSTALLED
CFCI - CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
Revisions: Date:
NOTE: REFER TO A101 FOR EQUIPMENT PLAN
COMBINATION FIRE/SMOKE DAMPER
FLEXIBLE ROUND DUCT
TURNING VANES
CONICAL TEE (SPIN-IN TYPE) WITH M.V.D.
SYMBOLS & ABBREVIATIONS LIST
MANUAL VOLUME DAMPER - M.V.D.
A.T.C. DAMPER (MOTOR OPERATED)
BRANCH DUCT WITH 45° CLINCH COLLAR
CONNECTION TO MAIN TRUNK DUCT
SUPPLY AIR DEVICE. ARROWS INDICATE
DIRECTION OF BLOW
AIR HANDLING UNIT
CUBIC FEET PER MINUTE
ACCESS PANEL
FLEXIBLE DUCT CONNECTION
PLAN NOTE REFERENCE SYMBOL
RIGID ROUND DUCT
CFM
FDC
T
AHU
AP
THERMOSTAT
F/S
HUMIDISTAT
FIRE DAMPERF.D.
H
RETURN AIR DEVICE. ARROWS INDICATE
DIRECTION OF BLOW.
EXHAUST AIR DEVICE.
OUTSIDE AIR DUCT.
BACKDRAFT DAMPERBDD
BRAKE HORSEPOWERBHP
BRITISH THERMAL UNITBTU
DRY BULBDB
DUCTLESS SPLIT SYSTEM CONDENSING UNITDCU
DUCTLESS SPLIT SYSTEMDSS
ENERGY EFFICIENCY RATIOEER
EXHAUST FANEF
EXTERNAL STATIC PRESSUREESP
ENTERING WATER TEMPERATUREEWT
FULL LOAD AMPSFLA
FEET PER SECONDFPS
GALLONS PER MINUTEGPM
HERTZH
HORSEPOWERHP
HOURHR
KILOWATTSKW
POUNDSLBS
LEAVING WATER TEMPERATURELWT
MAXIMUMMAX.
1000 BTU'S PER HOURMBH
MINIMUM CIRCUIT AMPACITYMCA
MINIMUMMIN.
MOTOR OPERATED DAMPERM.O.D.
NUMBERNO.
OUTSIDE AIROA
PHASEP
PRESSURE DROPPD
RUNNING LOAD AMPSRLA
ROTATIONS PER MINUTERPM
SEASONAL ENERGY EFFICIENCY RATIOSEER
VOLTSV
WET BULBWB
CONNECT TO EXISTING
REMOVE FROM EXISTING
EXHAUST AIREA
RETURN AIRRA
SUPPLY AIRSA
MECHANICAL EQUIPMENT DESIGNATION
STATES TYPE OF SYSTEM.
STATES NUMBER OR LETTER
CORRESPONDING TO RELATED
SCHEDULE.
AREA STATES NECK SIZES
LETTER REPRESENTS
MANUFACTURER &
MODEL NO.
AREA STATES CFM
AIR DEVICE DESIGNATION
RTU-XXX
CHILLED WATER RETURNCHWR
CHILLED WATER SUPPLYCHWS
COMPUTER ROOM AIR CONDITIONERCRAC
COMPUTER ROOM CONDENSING UNITCRCU
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C U s e rs
\a b ra d s to c k \D o c u m e n ts
\V D
C I_
C e n tr a l_
M R
I S it e
P re p a b ra d s to c k v e te ra n
-d c i.
c o m
.r v t
/2
/2
:4
:0
A
M
M-001
MECHANICAL SYMBOLS AND
ABBREVIATIONS
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021
MECHANICAL GENERAL NOTES
1. ALL WORK SHALL CONFORM TO LATEST INTERNATIONAL MECHANICAL AND PLUMBING CODES.
2. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS.
CONTRACTOR SHALL BE REQUIRED TO FURNISH, INSTALL AND CONNECT WITH APPROPRIATE SERVICES ALL ITEMS SHOWN ON THE DRAWING
AT NO ADDITIONAL COST TO OWNER.
3. CONTRACTOR SHALL INSTALL HVAC SYSTEMS TO ENSURE QUIET OPERATION. NO UNDUE VIBRATION OR SOUND SHALL BE TRANSMITTED
TO BUILDING STRUCTURE AND OCCUPIED AREAS.
4. ALL DUCTWORK SHALL BE INSTALLED COMPLY WITH SMACNA'S “HVAC DUCT CONSTRUCTION STANDARDS”, METAL AND FLEXIBLE.
UNLESS OTHERWISE NOTED, FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ASTM A 527.
5. PROVIDE AIR TURNING VANES AT ALL 90 DEGREE SUPPLY ELBOWS.
6. ALL DUCTWORK SHALL BE SEALED WITH A NON-HARDENING, NON-MIGRATING MASTIC OR LIQUID SEALANT. PROVIDE HOT-DIPPED GALVANIZED
STEEL FASTENERS, ANCHORS, RODS, STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK.
7. FABRICATE DUCT FITTINGS TO MATCH ADJOINING DUCTS AND TO COMPLY WITH DUCT REQUIREMENTS AS APPLICABLE TO FITTINGS.
LIMIT ANGULAR TAPERS TO 30 DEGREES FOR CONTRACTING TAPERS AND 20 DEGREES FOR EXPANDING TAPERS.
8. LOCATE ALL THERMOSTATS AND HUMIDISTATS 48” AFF UNLESS OTHERWISE NOTED. EXACT LOCATION OF ALL THERMOSTATS SHALL BE APPROVED BY ARCHITECT. ANY COORDINATION WITH ACTUAL ROOM FINISH SHALL BE DONE WITH NO ADDITIONAL COST.
9. CONTRACTOR SHALL CLEAN ALL COILS AND REPLACE ALL FILTERS AT SUBSTANTIAL COMPLETION.
10. THE CONTRACTOR SHALL REVIEW THE WORK AND SHALL COORDINATE WITH THE WORK OF OTHER TRADES.
11. ALL NEW DUCTWORK DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS.
12. SLEEVE AND SEAL ALL PIPING PASSING THROUGH WALLS, FLOORS AND ROOF UNLESS NOTED OTHERWISE.
13.
14.
ALL HANGERS AND SUPPORTS SHALL BE SECURED TO STRUCTURE ABOVE.
15.
ALL CUTTING, PATCHING AND REPAIR WORK SHALL BE THE RESPONSIBILITY OF THE TRADE INVOLVED.
16.
REFER TO ARCHITECTURAL PLANS FOR EXACT CEILING GRID LOCATIONS.
17.
ALL DUCTWORK INSULATION, FITTINGS, COVERS AND FINISHES SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50 AND ALL BE IN COMPLIANCE WITH NFPA 90A. REFER TO SPECIFICATIONS.
ALL EQUIPMENT MUST BE INSTALLED SUCH THAT FACTORY REQUIRED CLEARANCES FOR SERVICEABILITY ARE MAINTAINED. NOTIFY THE ENGINEER IMMEDIATELY SHOULD ANY EQUIPMENT HAVE ACCESS LIMITED BECAUSE OF FIELD CONDITIONS, EQUIPMENT ORIENTATION, ETC.
DO NOT INSTALL THIS EQUIPMENT UNTIL THE SITUATION HAS BEEN RESOLVED.
REMOVAL OF ITEMS SHALL INCLUDE ASSOCIATED HANGERS, ANCHOR BOLTS, AND OTHER APPURTENANCES. WHERE SUCH REMOVAL RESULTS IN OPEN HOLES, VOIDS OR EXPOSURE OF DAMAGED SURFACES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND FINISHING THE SURFACE TO MATCH ADJACENT CONDITIONS. THIS WORK SHALL BE COORDINATED WITH ARCHITECTURAL FINISH SCHEDULES
WHERE APPLICABLE.
OVERHEAD DUCTWORK AND PIPING IN SPACES WITH CEILINGS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL VERIFY REFRIGERANT PIPE SIZES WITH EQUIPMENT MANUFACTURER FOR THE INDICATED INSTALLATION.
18.
19.
20.
NN
119 108
L
K
J
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
MRI EQUIP. RM
2B166b
DRESS
2B166c
ELEC. CLOSET
2B166e
CORR.
C2-12
CHIEF
2B162
SEC'Y
2B164
CORR.
C2-10
COMMON VIEW
2B163
"x
"R
A
EX
8"ø SAEX.
"x
"S
A
EX
6"ø SAEX.
RX.
VAV-1
"x
"S
A
EX
40"x12"RAEX.
RX. 10"x10" SA RX. 14"x12" SA
RX. 16"x12" EA
46"x12" SAEX. 42"x12" SAEX. 36"x12" SAEX. 34"x12" SAEX.
6"x12" SAEX.
6"x12" SAEX.
6"ø SAEX.
8"ø SAEX.
RX. SUPPLY
DIFFUSER (TYP)
RX. 8" ⌀ EXH
RX.
DSS-1-A
RX. DSS-1B
RX. MRCC
RX. ACCU-1
RX. REFRIGERANT LINES
RX. REFRIGERANT LINES
RX. EF-1
RX.
VAV-2
RX. CRAC-1
RX. 16"x10" RA
RX. 16"x12" EA
1 1/4"ø HWREX. 1 1/4"ø HWSEX.
3/4"ø HWSEX.
3/4"ø HWREX.
EX. 190 CFM
(TYP. OF 2)
EX. 70
CFM
MRI SCAN RM ELEC RM 2B168
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C :\U se rs
\a br ad st oc k\
D oc um en ts \V
D C
I_ C en tra l_ M
R I S ite P re p_ ab ra ds to ck ve te ra n-dc i.c om .rv t 1/
/2
1:
:5
PM
MD-101
SECOND FLOOR PLAN -
MECHANICAL DEMOLITION
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021
1/4" = 1'-0"1 SECOND FLOOR PLAN - MECHANICAL DEMOLITION
1 CAP EXHAUST DUCT DURING CONSTRUCTION.
DUCTWORK TO BE REINSTALLED AFTER INSTALLATION
OF NEW MRI MACHINE.
RX. 3/4" CHILLED WATER SERVING EX. MRI CHILLER.
RX. 3/4" HWS & HWR TO NEAREST SHUTOFF VALVE
PLAN NOTES:
REMOVE EXISTING MRI EQUIPMENT AND ASSOCIATED
PIPING, VALVES, CONTROL PANELS AND ACESSORIES.
REMOVE EXISTING MRI CHILLER, PIPING, WIRING,
CONTROLS AND PANELS.
REMOVE EXSTING EQUIPMENT ROOM AIR
CONDITIONING INDOOR AND OUTDOOR UNIT. REMOVE
ALL REFRIGERANT PIPING, WIRING, AND CONTROLS.
REMOVE EXISTING ELECTRICAL CLOSET DUCTLESS
SPLIT SYSTEM.
REMOVE EXISTING VAV TERMINAL UNITS, CONTROLS,
AIR DEVICES, AND ALL DUCTWORK AND ACCESSORIES
DOWNSTREAM OF UNITS.
REMOVE EXISTING EXHAUST FAN AND DUCTWORK.
REMOVE ALL ABANDONED PIPING WITHIN MRI SUITE TO
MAXIMUM EXTENT POSSIBLE.
GENERAL NOTES:
A.
B.
C.
D.
E.
F.
G.
KEYPLAN - SECOND FLOOR
NOT TO SCALE
L
K
J
MRI SCAN ROOM
2B166a
MRI CONTROL
2B166d
MRI EQUIP. RM
2B166b
DRESS
2B166c
ELEC. CLOSET
2B166e
CORR.
C2-12
CHIEF
2B162
SEC'Y
2B164
CORR.
C2-10
COMMON VIEW
2B163
"x
"R
A E
X
8"ø SAEX.
16"x10"RAEX.
10"x10" SAEX.
6"ø SAEX.
"x
S
A E
X
40"x12"RAEX.
46"x12" SAEX. 42"x12" SAEX. 36"x12" SAEX. 34"x12" SAEX.
6"x12" SAEX.
6"x12" SAEX.
6"ø SAEX.
8"ø SAEX.
CRCU-2
DCU-2B
VAV-3
DSS-2A
CRAC-2
VAV-4
12"x10"10"x10" SA
14"x12" S A16"x10"RA
8"ø
A 150
C 500
12"x12"
8"ø SA
"x
S A
4"ø SA
EX. 190 CFM
(TYP. OF 2)
EX. 70
CFM
1 1/4"ø HWSEX.1 1/4"ø HWREX.
8"ø
A 150
8"ø
C 140
8"ø
A 135
4"ø
B 35
MRI SCAN RM ELEC RM 2B168
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C U s e rs
\a b ra d s to c k \D o c u m e n ts
\V D
C I_
C e n tr a l_
M R
I S it e
P re p a b ra d s to c k v e te ra n
-d c i.
c o m
.r v t
/2
/2
:4
:0
A
M
M-101
SECOND FLOOR PLAN -
MECHANICAL NEW WORK
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021
1/4" = 1'-0"
SECOND FLOOR PLAN - MECHANICAL NEW WORK
1 5.5" FLEX HOSE PROVIDED BY MRI MANUFACTURER.
SYSTEM AIR COOLING UNIT PROVIDED BY MRI
MANUFACTURER, INSTALLED BY CONTRACTOR
CONNECT 3/4" HWS & HWR TO NEW VAV BOXES
KKT CHILLER INTERFACE PANEL PROVIDED BY MRI
MANUFACTURER.
ROUTE REFRIGERANT PIPING TO ASSOCIATED INDOOR
UNIT. SIZE PER MANUTACTURER'S
RECOMMENDATIONS.
KKT CHILLER TO BE PROVIDED BY MRI
MANUFACTURER, INSTALLED BY CONTRACTOR.
CHWS & CHWR SIZED PER MANUFACTURER'S
RECOMMENDATIONS.
PLAN NOTES:
KEYPLAN - SECOND FLOOR
NOT TO SCALE
SMOKE DETECTION, TEMPERATURE SENSING,
THERMOSTATS, HUMIDITY SENSORS, FIRE
SUPPRESSION DUCT CONTROL UNITS, FIRE
FLASHERS/BUZZERS/ANNUNCIATORS AND O2
SENSORS, ETC, INSIDE EXAM ROOM MUST HAVE M.R.
COMPATIBILITY CERTIFICATION DOCUMENT. THEY
MUST HAVE NO MICRO-PROCESSOR CONTROL, NO
OSCILLATORS, NO STEPPER MOTORS, AND NO SOURCE
OF CLOCK SIGNAL. IF THEY HAVE ANY OF THESE
PREVIOUS ITEMS AND NO M.R. COMPATIBILITY
CERTIFICATE, THE DEVICE IS DISQUALIFIED FOR USE
INSIDE THE RF ROOM.
INSTALLATION OF SYSTEMS AND EQUIPMENT WITHIN
EXAM ROOM SHALL BE IN STRICT COMPLIANCE WITH
MANUFACTURER'S REQUIREMENTS.
GENERAL NOTES:
A.
B.
LOW PRESSURE BRANCH DUCT TAKE-OFF DETAIL
AIR
FLOW
SUPPLY ROUND DUCT RETURN OR EXHAUST
ROUND DUCT
ACOUSTICAL LINING
WHERE REQUIRED
MAIN DUCT
45° ON SHEET
METAL TRIM
PIECE TO RETAIN
ACOUSTIC LINING
MANUAL
VOLUME
DAMPER
DUCT SEALANT
BELLMOUTH
CONNECTION
ROUND RETURN
OR EXHAUST DUCT
FASTEN & SEAL
COLLAR TO DUCT
MAIN DUCT
MANUAL VOLUME
DAMPER
D
R=D/10 MIN.
BRANCH
DUCT
BELLMOUTH
CONNECTION
RECTANGULAR
SUPPLY DUCT
ROUND
SUPPLY DUCT
DUCT
SEALANT
MAIN DUCTMAIN DUCT
R=D/10 MIN.
DUCT
SEALANT
MEDIUM PRESSURE BRANCH DUCT TAKE-OFF
RECTANGULAR DUCT CONNECTION DETAIL
RETURN/EXHAUST
AIR FLOW
SUPPLY AIR FLOW
HAND DAMPER WITH
LOCKING TYPE
INDICATOR
QUADRANT ON HAT
SECTION
1/3 W & 5"MIN
45° CLINCH COLLAR
END BEARING
DUCT BRANCH
MAIN DUCT
1. FURNISH THIS TYPE CONNECTION WHEN SINGLE-LINE DUCTWORK IS INDICATED AS THIS
FOR BRANCHES WITH LESS THAN 25% OF THE TOTAL AIR FLOW
KEY NOTES:
DIRECTION OF AIR FLOW ROUND DUCT
CRIMP END AND SEAL AIR TIGHT
15" MAXIMUM TRANSITION
RECTANGULAR DUCT
NO SCALE
RECTANGULAR TO ROUND DUCT TRANSITION
TYPICAL PIPE HANGER DETAILS
INSULATED PIPES
(100mm AND ABOVE)
UNINSULATED PIPES
(100mm AND ABOVE)
INSULATED PIPES
(BELOW 100mm)
STANDARD PIPE
COVERING SHIELD
SPREADER TO BE USED
ON PIPE SIZES 250mm
AND ABOVE
SPREADER TO BE
USED ON PIPE SIZES
250mm AND ABOVE
UNINSULATED PIPES
(BELOW 100mm)
1. SUPPORT AIR TERMINAL UNIT AT BOTH ENDS WITH
MINIMUM 2" WIDE 22 GA GALV HANGER STRAPS.
NOTES:
2. USE FLEX DUCT CONNECTION WITH
RECTANGULAR DUCT.
CONCENTRIC SHEET METAL
REDUCER, ONE SIZE LARGER
THAN BOX INLET REQUIRED.
EXTERNAL INSULATION
IF NOT INTERNALLY
LINED
FLEX CONNECTION
WITH RECTANGULAR
DUCT (SEE NOTE 2)
HOT WATER
REHEAT COIL
CONTROLLER
MIN 3 X
DUCT DIA.
INSULATION AS
REQUIRED
EXTRACTORS OR
AIR SCOOP
BALANCING VALVE
SUPPLY DUCT
SUPPLY DUCT
NO SCALE
SINGLE DUCT VAV BOX W/ HOT WATER REHEAT DETAIL
HWR
HWS
STRAINER
BALL VALVE (TYP.)
CONTROL VALVE
FLEX DUCT
INDOOR WALL MOUNTED DUCTLESS SPLIT SYSTEM
WITH ROOF MOUNTED OUTDOOR UNIT
REFRIGERANT SUCTION/LIQUID LINES
TO BE SIZED AND INSTALLED PER
CONDENSING UNIT
MANUFACTURER'S
RECOMMENDATIONS
FLOOR
TO DISCHARGE OF CONDENSATE PUMP
MOUNTING WALL BRACKET
AS SUPPLIED BY
MANUFACTURER
3/8" GALVANIZED BOLTS (TYP.)
DUCTLESS SPLIT-TYPE AIR CONDITIONER
WALL MOUNTED INDOOR UNIT
(MOUNT UNIT AS HIGH AS POSSIBLE)
INDOOR UNIT MOUNTING
CD
R L
R S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C U s e rs
\a b ra d s to c k \D o c u m e n ts
\V D
C I_
C e n tr a l_
M R
I S it e
P re p a b ra d s to c k v e te ra n
-d c i.
c o m
.r v t
/2
/2
:4
:0
A
M
M-501
DETAILS - MECHANICAL
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021Revisions: Date:
OUTDOOR AIR VENTILATION CALCULATIONS
ASHRAE 170
ROOM AREA
ROOM
HEIGHT
(Az)
2B166a - MRI SCAN ROOM
2B166c - DRESS
2B166d - MRI CONTROL
NOTES:
1. OCCUPANCY CATEGORY TAKEN FROM ASHRAE 170-2017.
2. ALL ROOM AIR EXHAUSTED DIRECTLY TO OUTDOORS NOT REQUIRED.
3. OUTSIDE AIR DESIGN INTAKE AT VAV BOXES BASED ON A 30% OUTSIDE AIR INTAKE AT THE RTU. CONTRACTOR TO CONFIRM RTU OUTSIDE AIR INTAKE.
SQ. FT.
(Hz)
FT.
VOLUME OCCUPANCY CATEGORY MINUM
OUTDOOR AIR
CHANGES PER
HOUR
(Vz)
CU. FT.
2,920
2,184
SPECIAL EXAMINATION ROOM
SPECIAL EXAMINATION ROOM
SPECIAL EXAMINATION ROOM
ACH
ACH
MINIMUM
TOTAL AIR
CHANGES
PER HOUR
BREATHING ZONE
OA
(Vbz)
CFM
ZONE AIR
DISTRIBUATION
EFECTIVENESS
MIN ZONE OA
OA
SYSTEM
(Ez)
0.80
0.80
0.80
(Voz)
CFM
VAV-3
VAV-4
MIN ZONE
SUPPLY
SUPPLY
AIR
DESIGN
CFM
(Vpz)
CFM
OUTSIDE AIR
FRACTION
MAX.
OUTSIDE AIR
FRACTION
SYSTEM
VENTILATION
EFFICIENCY
Diversity
Factor
UNCORRECCTED OA
INTAKE
(Zp)
0.20
0.23
0.22
Max. (Zp)
0.20
0.23
(Ev)
0.90
0.80
D
1.00
1.00
(Vou)
CFM
OA INTAKE
FLOW RATE
(Vot)
CFM
DESIGN OA
INTAKE
MEETS
CODE
NOTES
CFM
YES / NO
YES
YES
ALL
ALL
ALL
1. PROVIDE INTEGRAL CONDENSATE PUMP
2. REFRIGERANT PIPING TO BE SIZED AND INSTALLED PER
MANUFACTURERS RECOMMENDATIONS.
3. FACTORY FURNISHED CONTROLS WITH WALL MOUNTED THERMOSTAT.
1. MRI MACHINE AND ASSOCIATED CHILLER UNIT TO BE PROVIDED BY PHILLIPS
AND INSTALLED BY CONTRACTOR.
MARK
INDOOR UNIT
SUPPLY
AIR CFM
MANUFACTURER &
MODEL NO.
COOLING
MBH
MOTOR
HP
V-P-H REMARKS MARK
MANUFACTURER &
MODEL NO.
V-P-H REMARKS
OUTDOOR UNIT
3,500
LIEBERT
PX023UA1ADH298
81.20 4.2 460-3-60 ALL
LIEBERT
MCM040E1ADR360
460-3-60 ALL
1. UPFLOW WITH FRONT AIR RETURN
2. PROVIDE LIEBERT iCOM CONTROL WITH HIGH DEFINITION DISPLAY
3. DIGITAL SCROLL, VARIABLE CAPACITY COMPRESSOR UTILIZING R-410A
4. EVAPORATOR TYPE: TILTED-SLAB, COPPER TUBES - ALUMINUM FINS WITH HYDROPHILIC COATING
5. TWO-STAGE 12kW ELECTRIC REHEAT
6. DUAL-FLOAT CONDENSATE PUMP FACTORY MOUNTED INTERNAL TO UNIT
7. FILTER RATING: MERV 8 PER ASHRAE 52.2-2007
8. TEMPERATURE/ HUMIDDITY SENSORS INTERNAL FOR RETURN AIR SENSING
MARK
HEATING
DESIGN
CFM
MANUFACTURER &
MODEL NO.
INLET
SIZE
REMARKS
PRICE
SDV
ALL300
HOT WATER REHEAT HEATING COIL DATA
GPM V-P-H
1.0 8"
ROUND
55 115-1-60
BOX MIN.
CFM
E.A.T. L.A.T.
CAPACITY
MBH
10.8 85
HD LOSS
0.68
PRICE
SDV
ALL160 0.5
6"
ROUND
55 115-1-6065 6.0 85 0.14
FLA
1.4
COOLING
DESIGN
CFM
ESP
IN. WG
ELECTRIC
REHEAT
KW
FLA
33.7
MCA
40.8
MOCP
50.0
MCA
1.8
MOCP
MARK
AIR DEVICE SCHEDULE
SYSTEM MANUFACTURER AND
MODEL NUMBER
REMARKS
TYPE
SUPPLY
DIFFUSER
A
RETURN
DIFFUSER
B
PRICE
SPD
SUPPLY
DIFFUSER
C
PRICE
SPD
COMPUTER ROOM AIR CONDITIONING UNIT SCHEDULE
CRAC-2 CRCU-2
REMARKS:
DUCTLESS SPLIT SYSTEM SCHEDULE
DSS-2A
MAX CFM
MANUFACTURER &
MODEL NO.
MARK
TOTAL COOLING
BTU/HR
MARK
MANUFACTURER &
MODEL NO.
V-P-HFLA MCA
REMARKS
OUTDOOR UNITINDOOR UNIT
MITSUBISHI
MSY-GL24NA-U1
22,500
MITSUBISHI
MUY-GL25NA-U1
0.76 17.1 ALLDCU-2B 208-1-60
REMARKS:
VARIABLE AIR VOLUME TERMINAL SCHEDULE W/ HOT WATER REHEAT
REMARKS:
1. HEATING CAPACITIES ARE BASED ON 180°F ENTERING WATER TEMPERATURE AND 55°F ENTERING AIR TEMPERATURE.
2. PRESSURE INDEPENDENT AIRFLOW CONTROL.
3. PROVIDE SPACE MOUNTED THERMOSTAT.
VAV-3
VAV-4
ALUMINUM CONSTRUCTION, 24"x24" MODULE, FULL FACE FRAME. 4-WAY
BLOW, UNLESS OTHERWISE INDICATED.
ALUMINUM CONSTRUCTION, 12"x12" MODULE, FULL FACE FRAME.
4-WAY BLOW, UNLESS OTHERWISE INDICATED.
24"x24" MODULE SIZE, STEEL CONSTRUCTION W/ ALUMINUM FACE
SCREEN. ROUND DUCT CONNECTION.
PRICE
PDDR
V-P-H
208-1-60
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C U s e rs
\a b ra d s to c k \D o c u m e n ts
\V D
C I_
C e n tr a l_
M R
I S it e
P re p a b ra d s to c k v e te ra n
-d c i.
c o m
.r v t
/2
/2
:4
:0
A
M
M-601
MECHANICAL SCHEDULES
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
PD
CD
EX. G
R
M
BALANCING VALVE
BUTTERFLY VALVE
PRESSURE REDUCING VALVE
BACKFLOW DEVICE
SYMBOLS & ABBREVIATIONS LIST
3 WAY CONTROL VALVE (MODULATING TYPE)
2 WAY CONTROL VALVE (MODULATING TYPE)
FLOOR DRAINF.D.
UNION
STRAINER
THERMOMETER
GATE VALVE
CHECK VALVE
GALLONSGAL
GALLONS PER HOURGPH
GALLONS PER MINUTEGPM
HEADHD
HORSE POWERHP
THOUSAND BRITISH THERMAL UNITS PER HOURMBH
TYPICALTYP.
HERTZHz
PHASEP
VOLTSV
EXISTINGEX.
SANITARY PIPE, SAN
COLD WATER PIPE, CW
HOT WATER PIPE, HW
VENT PIPE, V
PLAN NOTE REFERENCE SYMBOL
CONNECT TO EXISTING
REMOVE FROM EXISTING
PUMP DISCHARGEPD
GAS PRESSURE REGULATOR
GAS COCK
VACUUM BREAKER
WATER HAMMER ARRESTOR
CONDENSATE
GAS
PUMP DISCHARGE
WATER METER
PUMP
EXPANSION TANKET
DOWNDN
CW
CO
CFH
CD
COLD WATER
CLEAN OUT
CUBIC FEET PER HOUR
CONDENSATE
FCO FLOOR CLEAN OUT
FP FIRE PROTECTION
G GAS
PSI POUNDS PER SQUARE INCH
SAN. SANITARY
VTR VENT THROUGH ROOF
HOT WATERHW
FEETFT
STORM WATERST
DISCHARGEDISC.
NUMBERNO.
INCHESIN.
POUNDSLBS.
FAHRENHEIT (DEGREES)°F
PIPE DOWN
PIPE AWAY
PIPE UP
HYDRANT
CLEAN OUT
CAPPED
FLOW ARROW
FLANGE
EXISTING GAS
SYSTEM
NUMBER
RISER DESIGNATION
GAS COCK
MEDIUM PRESSURE STEAMMPS
VACUUMVAC.
CHW CHILLED WATER
MEDICAL AIRMA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ARCHITECTS:
C U s e rs
\a b ra d s to c k \D o c u m e n ts
\V D
C I_
C e n tr a l_
M R
I S it e
P re p a b ra d s to c k v e te ra n
-d c i.
c o m
.r v t
/2
/2
:4
:1
A
M
P-001
PLUMBING GENERAL NOTES,
SYMBOLS AND ABBREVIATIONS
VETERAN DESIGN & CONSTRUCTION, INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MD 21228
443.543.5081
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MD 20815
301.718.0080
SITE PREP FOR MRI
REPLACEMENT
VAMC HUNTINGTON, WV
581-20-904
BUILDING 1
1.20.2021
1. ALL SPECIFICATIONS AND DRAWINGS AR COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION
INFORMATION.
2. INSTALLATION OF ALL PLUMBING SYSTEMS ASSOCIATED WITH THE NEW MRI MACHINE SHALL BE IN ACCORDNACE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS AND APPLICABLE REQUIREMENTS.
This is the start of the file's text. The full file is on GovTribe.