S02 Fire Alarm System Inventory and Testing Table.xlsx

XLSX spreadsheet 11 KB Posted

Attached to
Minneapolis VAHCS Fire Alarm Maintenance Pre-Solicitation/Solicitation
Solicitation number
36C26327Q0013
Issued by

About this file

This file is a Fire Alarm System Inventory and Testing Table detailing the fire alarm equipment across multiple buildings at the Minneapolis Veterans Affairs Health Care System (VAHCS) facility. The spreadsheet documents the quantity and annual inspection requirements for various fire alarm components across 19 buildings, including signaling line circuits, manual pull stations, area smoke detectors, duct smoke detectors, heat detectors, sprinkler water flow detectors, voice alarm channels, nonvoice audible systems, valve supervisory switches, horns and strobes, backup batteries, main fire alarm panels, annunciation panels, data center suppression systems, and fire alarm roll-down doors. Building 70 requires semi-annual inspections for area smoke detectors, while Building 222 and 224 are noted as not connected to the main fire alarm control panel (FCP).

The inventory reveals significant variation in equipment distribution across facilities, with Building 70 containing the largest concentration of fire alarm components, including 5,248 area smoke detectors, 302 manual pull stations, 136 voice alarm channels, 300 horns and strobes, and 252 valve supervisory switches. All equipment is subject to annual testing and inspection as specified in this maintenance table, which serves as a baseline for the fire alarm system servicing requirements under the Minneapolis VAHCS Fire Alarm Maintenance Solicitation (36C26327Q0013), with an offer deadline of September 21, 2024.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Building910474849686970727374757678798089222 (Not connected to main FCP)224 (Not connected to main FCP)Inspection Frequency
Signaling Line Circuit22212225422222111122Annually
Manual Pull Stations128531967302422810055685Annually
Area Smoke Detectors80108193473130852484112548120623336117Annually (Except Building 70 CLC, inspected on a semi-annual basis)
Duct Smoke Detectors01027005000035013100Annually
Heat Detectors5200010945000500024322Annually
Sprinkler Water Flow Detectors870092115401105011000Annually
Voice Alarm Channels000000013600003022000Annually
Nonvoice audible sys4436044103822202000042Annually
Valve Supervisory Switches12900154325202307111100Annually
Horns and Strobes36228027341030065170260 (elevator areas)4136271612Annually
Backup Batteries2222222222222044222Annually
Main Fire Alarm Panel1111111111111111111Annually
Annunciation Panel1111111111111111111Annually
Data Center Suppresion System0000000100000000000Annually
Fire Alarm Roll Down Doors0000000100001000000Annually

File details come from the government source that posted it. Updated .