S02 - Drawings.pdf
PDF 5 MB Posted
- Attached to
- Z2DA--VETERANS HEALTH-PRIVACY AND DECENCY
- Solicitation number
- 36C25923R0084
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S05 - RFIs and Responses FINAL.pdf | ||
| 36C25923R0084 0005.docx | DOCX document | |
| 36C25923R0084 0004.docx | DOCX document | |
| S06 - ICRA Template.pdf | ||
| 36C25923R0084 0003.docx | DOCX document | |
| Veterans Health Sheridan VAMC Takeoff 06142023.pdf | ||
| S05 - RFI for Curtain Fabrics_Color.pdf | ||
| 36C25923R0084 0002.docx | DOCX document | |
| S04 - Site Visit Sign-In Roster 06142023.pdf | ||
| S04 - Site Visit Meeting Doc_Vet Health.pdf | ||
| 36C25923R0084 0001.docx | DOCX document | |
| S05 - RFIs and Responses 2023.pdf | ||
| S02 - Design Alert.pdf | ||
| S02 - Specifications.pdf | ||
| 36C25923R0084_1.docx | DOCX document | |
| S22 - Blank LOS Cert.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:2
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
COVER SHEET
G-000
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23
VETERAN'S HEALTH - PRIVACY AND
DECENCY
SHERIDAN VA MEDICAL CENTER
SHERIDAN, WYOMING
ARCHITECT & MECHANICAL ENGINEER
FOURFRONT DESIGN INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PHONE (605) 342-9470
TASK ORDER NUMBER: 36C25920N0350
CONTRACT NUMBER: VA259-16-D-0217
PROJECT NUMBER: 666-19-104
666-19-104
SHEET INDEX
GENERAL
G-000 COVER SHEET
G-001 ABBREVIATIONS, LEGEND AND SYMBOLS
G-002 LOCATION MAP
ARCHITECTURAL
A-001 DOOR SCHEDULE AND DETAILS AND WALL TYPES
A-010 SIGNAGE SCHEDULE
A-100 BUILDING 5 AND 6 FIRST FLOOR PLANS
A-101 BUILDING 7 AND 8 FIRST FLOOR PLANS
A-102 BUILDING 71 FIRST AND THIRD FLOOR PLANS
A-103 BUILDING 71 THIRD FLOOR PLANS
A-104 BUILDING 71 THIRD FLOOR PLANS
A-105 BUILDING 71N FIRST FLOOR PLANS
A-106 BUILDING 71N FIRST FLOOR PLANS
A-107 BUILDING 71N SECOND FLOOR PLANS
A-108 BUILDING 71N SECOND FLOOR PLANS
A-109 BUILDING 86 FIRST FLOOR PLANS A
A-110 BUILDING 86 FIRST FLOOR PLANS B
A-111 BUILDING 86 SECOND FLOOR PLANS A
A-112 BUILDING 86 SECOND FLOOR PLANS A
A-113 BUILDING 86 SECOND FLOOR PLANS A
A-114 BUILDING 86 SECOND FLOOR PLANS B
A-115 BUILDING 86 SECOND FLOOR PLANS B
A-116 BUILDING 86 THIRD FLOOR PLANS
A-117 BUILDING 87 FIRST FLOOR PLANS
1 23
# POUND OR NUMBER
& AND
@ AT
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ACT ACOUSTIC CEILING TILE
AD AREA DRAIN
AFF ABOVE FINISH FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ALUM ALUMINUM
ANOD ANODIZED
ASD ALTERNATE STRESS DESIGN
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
BD BOARD
BLK BLOCK
BM BEAM
B.O. BOTTOM OF
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BLDG BUILDING
BYND BEYOND
CAB CABINET
CER CERAMIC
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMPR COMPRESSIBLE
CONC CONCRETE
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CPT CARPET
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CT CERAMIC TILE
DBL DOUBLE
DEMO DEMOLISH OR DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DN DOWN
DR DOOR
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR OR ELEVATION
EPDM ETHYLENE PROPYLENE DIENE M-CLASS (ROOFING)
EQ EQUAL
ES EACH SIDE
EXIST EXISTING
EXP Bolt EXPANSION BOLT
EXP JT EXPANSION JOINT
EXT EXTERIOR
FD FLOOR DRAIN OR FIRE DEPARTMENT
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FM FILLED METAL
FND FOUNDATION
F.O. FACE OF
FT FOOT OR FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GP GUSSET PLATE
GR GRADE
GYP GYPSUM
HC HOLLOW CORE
HDR HEADER
HEF HORIZONTAL EACH FACE
HI HIGH
HIF HORIZONTAL INSIDE FACE
HM HOLLOW METAL
HOF HORIZONTAL OUTSIDE FACE
HOR HORIZONTAL
HP HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
ICBO INTERNATIONAL CONFERENCE OF BUILDING
OFFICIALS
ID INSIDE DIAMETER
ILO IN LIEU OF
IN INCH
INCL INCLUDE
INSUL INSULATED OR INSULATION
INT INTERIOR
INV INVERT
IRGWB IMPACT RESISTANT GYPSUM WALL BOARD
JST JOIST
JT JOINT
K KIP (1000 POUNDS)
LLV LONG LEG VERTICAL
LP LOW POINT
LVL LEVEL
LW LIGHT WEIGHT
LWC LIGHT WEIGHT CONCRETE
MAS MASONRY
MAX MAXIMUM
MCB METAL CORNER BEAD
MECH MECHANICAL
MEMBR MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURED
MIN MINIMUM
MO MASONRY OPENING
MRGWB MOISTURE-RESISTANT GYPSUM WALL BOARD
MTL METAL
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NWC NORMAL WEIGHT CONCRETE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OZ OUNCE
PC PILE CAP
PCC PRE-CAST CONCRETE
PL PLATE
P.LAM PLASTIC LAMINATE
PLUMB PLUMBING
PLY PLYWOOD
PORC PORCELAIN
PNL PANEL
PNT PAINT OR PAINTED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PT POINT
PR PAIR
PROP PROPERTY
PVC POLYVINYL CHLORIDE
ABBREVIATIONS
R RADIUS
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE RIGHT END
REINF REINFORCED
REF REFERENCE
REQD REQUIRED
RET RETURN
RETG RETAINING
RM ROOM
R.O. ROUGH OPENING
ROW RIGHT OF WAY
SC SOLID CORE
SDI STEEL DECK INSTITUTE
SECT SECTION
SF STEP FOOTING OR SQUARE FOOT
SHT SHEET
SIM SIMILAR
SL SPLICE LENGTH
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SPEC SPECIFIED OR SPECIFICATION
SPK SPRINKLER OR SPEAKER
SQ SQUARE
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIFF STIFFENER
STL STEEL
STR STAIR
STRUCT STRUCTURE OR STRUCTURAL
SUP SUPPORT
SYM SYMMETRICAL
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
T/D TELEPHONE/DATA
TEL TELEPHONE
TEMP TEMPERATURE
THK THICK OR THICKNESS
THRD THREADED
TLT TOILET
T.O. TOP OF
T.O.C TOP OF CONCRETE
T.O.F TOP OF FRAMING
T.O.S TOP OF STEEL/STUD
T.O.W TOP OF WALL
TPD TOILET PAPER DISPENSER
TYP TYPICAL
U/S UNDERSIDE
UNO UNLESS NOTED OTHERWISE
US UNDERSIDE
VB VAPOR BARRIER
VCT VINYL COMPOSITE TILE
VEF VERTICAL EACH FACE
VERT VERTICAL
VIF VERIFY IN FIELD
VOF VERTICAL OUTSIDE FACE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W/ WITH
WD WOOD
WDW WINDOW
WP WORKING POINT
WRB WEATHER RESISTANT BARRIER
WWF WELDED WIRE FABRIC
Room name
1t
VIEW NAME
1/8" = 1'-0"1 DRAWING TITLE
SCALE
BUILDING SECTION
DIRECTION OF SIGHT
DRAWING NUMBER
SHEET NUMBER
WALL SECTION
DETAIL CUT
A101
DETAIL CALLOUT
A101
A101
A101
A101
DIRECTION OF SIGHT
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
INTERIOR ELEVATION
DRAWING NUMBER
DIRECTION OF SIGHT
SHEET NUMBER
ROOM TAG
ROOM NAME
ROOM NUMBER
KEYNOTE TAG
5-04 KEYNOTE DESIGNATION
1 DOOR TAG
DOOR NUMBER
PARTITION TAG
WALL DESIGNATION
WINDOW TAG
WINDOW DESIGNATION
ELEVATION MARKER
HEIGHT
NORTH ARROW
TRUE NORTH
PLAN NORTH
ARCHITECTURAL SYMBOLS
M3A
STEEL/METAL
WOOD (ROUGH) BLOCKING OR SHIM
BRICK
GRAVEL
EARTH/ENGINEERED FILL
CONCRETE MASONRY
PLAN AND SECTION
WOOD (ROUGH)
ACOUSTIC CEILING TILE
GYPSUM BOARD
CEILING
CONCRETE
ELEVATION
CENTER LINE
LINE SYMBOLS
GRID LINE
PROPERTY LINE
CUT LINE
BATT INSULATION
WOOD SUBSTRATE
RIGID INSULATION
MATERIAL LEGEND
WM - WALK OFF MAT
EF - EPOXY FLOORING (TROWELED)
FLOORING
BID ALTERNATE
CPT - CARPET
CONC - CONCRETE
PT - PORCELAIN TILE
FIBER CEMENT PANEL SIDING
CORRUGATED METAL PANEL
STANDING SEAM METAL ROOF/
SIDING PANEL
LEGEND NOTES
1. THESE LEGENDS ARE COMPOSED OF STANDARD
SYMBOLS AND ARE PERNTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT
APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR OTHER LEGENDS MAY
APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON
THIS SHEET.
V.A. SYMBOLS
FIRE RESISTIVE RATED LINE, 1 HOUR
FIRE RESISTIVE RATED LINE, 2 HOUR
FIRE RESISTIVE RATED LINE, 3 HOUR
FIRE RESISTIVE RATED LINE, 4 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 1 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 2 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 3 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 4 HOUR
V V ITEM - VA SUPPLIED AND INSTALLED
VC ITEM - VA SUPPLIED AND CONTRACTOR INSTALLED
CC ITEM - CONTRACTOR SUPPLIED AND INSTALLED
A
COLUMN GRID
DIMENSION LINE
NORTH ARROW
CL CENTER LINE
N
NOTES
1. AT NO TIME SHALL CONSTRUCTION ACTIVITIES IMPEDE NORMAL DAILY OPERATION OF THE VA
MEDICAL CENTER WITHOUT PRIOR APPROVAL OF THE CONTRACTING OFFICER.
2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
3. THE CONTRACTOR SHALL PERFORM ALL TESTING AND INSPECTIONS AS SPECIFIED, OR AS
NECESSARY TO DEMONSTRATE A COMPLETE AND SATISFACTORY INSTALLATION.
4. THE CONTRACTOR SHALL PROTECT EXISTING BUILDING AND SITE MATERIALS SCHEDULED TO
REMAIN, AND SHALL BE RESPONSIBLE FOR DAMAGE TO THE SAME RESULTING FROM WORK UNDER
THIS CONTRACT. THE CONTRACTOR SHALL RESTORE DAMAGED EXISTING BUILDING AND SITE
MATERIALS TO THEIR ORIGINAL CONDITION.
5. THE CONTRACTOR SHALL COORDINATE ON-SITE STORAGE OF BUILDING MATERIALS, EQUIPMENT, AND TRASH CONTAINERS WITH CONTRACTING OFFICER PRIOR TO COMMENCEMENT OF WORK.
6. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE SUPPLIED BY THE SAME
MANUFACTURER, AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM
DEFECTS.
7. IT IS THE INTENT OF THIS CONTRACT THAT ALL AREAS AFFECTED BY CONSTRUCTION SHALL PROVIDE A FINISHED AND COMPLETE PROJECT. CONTRACTOR SHALL PATCH, REPAIR, AND ADJUST
AS REQUIRED TO ACHIEVE THIS FINISHED PROJECT.
8. CONTRACTOR SHALL INSPECT SITE AND FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO
COMMENCING CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER IMMEDIATELY
OF ANY DISCREPANCIES.
9. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, AND SHALL BE RESPONSIBLE FOR PROPER FIT
OF ALL ITEMS. CONTRACTOR SHALL COORDINATE ALL WORK AND SHOP DRAWINGS WITH OTHER
TRADES.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. CONTRACTOR SHALL ANTICIPATE AREAS WHERE THE INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WILL BE RESTRICTED, CONGESTED, OR DIFFICULT TO INSTALL, AND SHALL COORDINATE INSTALLATION
BETWEEN TRADES.
11. CONTRACTOR SHALL COORDINATE ALL WORK AND SHOP DRAWINGS WITH OTHER TRADES.
12. ALL BUILDING DIMENSIONS ARE FACE TO STUD, FACE OF MASONRY, AND EXTERIOR WINDOW OR
DOOR ROUGH OPENING.
13. ALL ANGLES ON PLANS ARE 45- OR 90-DEGREES, UNLESS NOTED OTHERWISE. CURVED ELEMENTS
ARE LOCATED AS DIMENSIONED.
14. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS EXISTING.
15. INSTALL BLOCKING WITHIN PARTITIONS AS REQUIRED FOR INSTALLATION OF WALL-MOUNTED
CABINETS, TOILET ACCESSORIES, WALL STOPS, AND MISCELLANEOUS ITEMS.
16. SEE SHEET A-001 FOR WALL TYPES.
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:2
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
ABBREVIATIONS, LEGEND AND
SYMBOLS
G-001
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 2 23
ST
A
IR
#5
23 24
108 28
UP
UP DN
B
AT
H
#1
ST
A
IR
B
A u p u p
C
OM
M
H UB
E X
IS
T.
E
LE
V
U P
D
OW
N
D
OW
NU
P
D
OW
NU
P
U P
D N
D N
U P
D N
D N
BUILDING 1
STATE FIRE MARSHAL
EXPERIENCE WORKS
DRIVER REHABILITATION PROGRAM
BUILDING 2
VACANT
BUILDING 3
VACANT
BUILDING 4
BUISNESS OFFICE
HUMAN RESOURCES
FINANCIAL OFFICE
TELE HEALTH
CONTRACTING OFFICE
BUILDING 5
FACILITIES MGMT SERVICE
NURSING ADMINISTRATION
SAFETY / GEMS / EMERG MGMT
DAV (DISABLED AMERICAN VETERANS
BUILDING 6
RESIDENTIAL TREATMENT PROGRAMS
PRRTP / PRRP
BUILDING 7
AQUISITION AND LOGISTICS SERVICE (A&LS)
NUTRITION / FOOD SERVICE
LIBRARY
LEARNING CENTER
CHAPEL
BUILDING 8
MENTAL HEALTH UNIT
BUILDING 9
MEDICAL CENTER DIRECTOR
CHIEF OF STAFF
POLICE
RESPIRATORY THERAPY
BUILDING 10
QUARTERS
BUILDING 11
HOBBY SHOP (UNUSED)
BUILDING 12
QUARTERS
BUILDING 13
QUARTERS
BUILDING 14
QUARTERS 14A AND 14B
BUILDING 15
QUARTERS 15A AND 15B
BUILDING 16
QUARTERS 16A AND 16B
BUILDING 17
QUARTERS 17A AND 17B
BUILDING 18
QUARTERS 18A AND 18B
BUILDING 19
QUARTERS 19A AND 19B
BUILDING 20
QUARTERS 20A AND 20B
BUILDING 21
QUARTERS 21A AND 21B
BUILDING 22
QUARTERS 22
BUILDING 23
BOWLING ALLEY
BUILDING 24
VOA (VOLUNTEERS OF AMERICA) HOMELESS SHELTER
BUILDING 27
QUARTERS
BUILDING 28
QUARTERS
BUILDING 31
TEXTILE CARE FACILITY
LAUNDRY SERVICES
BUILDING 32
AFGE (LEASED)
BUILDING 35
FMS MAINTANCE STORAGE
BUILDING 37
FMS CARPENTER SHOP
FMS MAINTENANCE OFFICES
BUILDING 42
BUILDING 55
FMS PAINT / MASON SHOP
BUILDING 61
AUDITORIUM
VOLUNTARY SERVICES
RECREATION
BUILDING 71
PHARMACY
DENTAL CLINIC
EYE CLINIC
AUDIOLOGY
DIGESTIVE DISEASES
BUILDING 71N
AMBULANCE ENTRANCE
AMBULATORY CARE
MEDICAL UNIT
PATIENT ADMISSIONS
RADIOLOGY
LABORATORY
BUILDING 86
MOUNTAIN VIEW LIVING CENTER
SNU (SPECIAL NEEDS UNIT)
PHYSICAL THERAPT (PT)
OCCUPATIONAL THERAPY
CANTEEN SERVICE
BUILDING 87
BUILDING 90
BOILER PLANT
BUILDING 108
BUILDING 109
PICNIC SHELTER
SITE INDEX
CONTRACTOR STAGING AREA
AREAS IN SCOPE
SITE LEGEND
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:2
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
LOCATION MAP
G-002
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23
1" = 160'-0"
SITE MAP
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
N
3 23
WD-F HM-001
2"
SEE SCHED
2"
S E
E S
C H
E D
U L E
5/8" TYPE 'X' GYPSUM BOARD
3 5/8" METAL STUDS AT 16" O.C.
5/8" TYPE 'X' GYPSUM BOARD
5/8" TYPE 'X' GYPSUM BOARD
3 5/8" METAL STUDS AT 16" O.C.
BATT INSULATION
5/8" TYPE 'X' GYPSUM BOARD
3 5/8" METAL STUDS AT 16" O.C.
BATT INSULATION
5/8" TYPE 'X' GYPSUM BOARD
M3A
M3B
M3C
NOTE:
1. PROVIDE CEMENT BOARD IN LIEU OF GYPSUM
BOARD AT ALL TILE LOCATIONS. TRANSITION TO
GYPSUM BOARD AT PAINTED SURFACES.
5/8" CEMENT BOARD (TILE BACKER)
EXIST. PARTITION WALL
M1A
NOTE:
1. AT SHOWER LOCATIONS SUBSTITUTE 5/8" CEMENT BOARD
FOR 5/8" GYPSUM BOARD.
2. PROVIDE CEMENT BOARD IN LIEU OF GYPSUM BOARD AT
ALL TILE LOCATIONS. TRANSITION TO GYPSUM BOARD AT
PAINTED SURFACES.
5/8" TYPE 'X' GYPSUM BOARD
1 5/8" METAL STUDS AT 16" O.C.
BATT INSULATION
M1C
NOTE:
1. WALL TYPE M1A APPLIES TO ALL EXISTING SHOWER
WALLS TO REMAIN, BUT SCHEDULED TO RECIEVE NEW
WALL TILE OR SHOWER PANELS.
B4A
4" CMU
NOTE: NOT ALL WALL TYPES ARE USED REFER TO FLOOR
PLANS FOR WALL TYPES USED.
NOTE:
1. DELETE ONE SIDE OF GYPSUM BOARD IF WALL DOES
NOT ISOLATE ROOM OR ABUTTS AN EXISTING WALL
6" METAL STUD WALL,
SEE WALL TYPES
HOLLOW METAL DOOR
FRAME, FILL WITH
LIGHTWEIGHT PLASTER
DOOR, SEE SCHEDULE
SEALANT
5/8" GYPSUM BOARD
4 3/8"
5/8" GYPSUM BOARD
HOLLOW METAL DOOR
FRAME, FILL WITH
LIGHTWEIGHT PLASTER
DOOR, SEE SCHEDULE
SEALANT
6" METAL STUD WALL,
SEE WALL TYPES
DOOR, SEE
SCHEDULE
CONCRETE SLAB,
SEE STRUCTURAL
THRESHOLD, SET
IN SEALANT
DOOR FRAME
BEYOND
3 1/2" 4 1/2"
EXISTING FLOORING
HM-F HOLLOW METAL FRAME
WD-BF WOOD BI-FOLD
FTF FACTORY TRANSPARENT FINISH
EXIST EXISTING
DOOR LEGEND
EXISTING CEILING WIRES
SUSPENDED FROM ABOVE
(TYP.)
EXISTING ACT CEILING
ASSEMBLY TO REMAIN
EXISTING CEILING GRID
SHEET METAL SCREW AT
EACH GRID AT 24" O.C.
PRIVACY CURTAIN ALUMINUM
TRACK. SEE SPECIFICATIONS.
NEW CURTAIN CARRIER.
SEE SPECIFICATIONS
1 1/4"
/8
TOGGLE BOLT 24" O.C.
EXISTING SHEETROCK
PRIVACY CURTAIN ALUMINUM
TRACK, SEE SPECIFICATIONS.
NEW CURTAIN CARRIER, SEE
SPECIFICATIONS
/8
1 1/4"
3' - 0" MAX.
1' - 0" 3' - 6"
6" MAX. 3' - 0"
2' - 0"
ADA WATER CLOSET SOAP DISPENSER BABY CHANGING
STATION
SANITARY NAPKIN
DISPOSAL
SANITARY NAPKIN
DISPENSER
B
DA
C
PAPER TOWEL
DISPENSER
COUNTERTOP
"COUNTERTOP
T
O
MATCH EXISTING
FOR HEIGHT
METAL STUD
20 GA. CONTINIOUS TRACK FOR
HANGING.
5/8" TYPE 'X' GYPSUM BOARD
CEILING, SEE FINISH SCHEDULE
T Y
P
TYPE
WALL
HARDWARE SET NO. 1
1/2 PAIR HINGES CB1900R 4-1/2" x 4-1/2" US26D
1 PAIR SPRING HINGES 2060R US26D
1 EACH PRIVACY SET 93K-0-L-15D-S3 626
1 EACH KICK PLATE US32D
1 SET SMOKE SEAL
1 EACH WALL STOP #403 US26D
HARDWARE SET NO. 2
1 EACH PRIVACY SET 93K-0-L-15D-S3 626
HARDWARE SETS
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:0
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
DOOR SCHEDULE AND DETAILS AND
WALL TYPES
A-001
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
1/4" = 1'-0"
DOOR ELEVATIONS
1/4" = 1'-0"
DOOR FRAMES
4 23
1 1/2" = 1'-0"
WALL TYPES
DOOR SCHEDULE
MARK WIDTH HEIGHT THICKNESS COUNT PANEL TYPE PANEL MATERIAL PANEL FINISH GLAZING TYPE FRAME TYPE FRAME MATERIAL FRAME FINISH HEAD JAMB SILL SILL HEIGHT FIRE/SMOKE RATING STC RATING HARDWARE GROUP ELECTRICAL COMMENTS
B6-111 3' - 0" 7' - 0" 1 3/4" 1 WD-F WD EXIST - HM-001 HM PT - - - 0" - - HW#2 - SEE SPECIFICATION
B71N-131A 2' - 0" 7' - 0" 1 3/4" 1 WD-BF WD SEE MANUFACTURER - WD WD WD - - - 0" - - BY MANUFACTURER - SEE SPECIFICATION
B86-106C 3' - 0" 7' - 0" 1 3/4" 1 WD-F WD FTF - HM-001 HM PT 2/A-001 3/A-001 4/A-001 0" - - HW#1 - SEE SPECIFICATION
3" = 1'-0"
INTERIOR - HM DOOR HEAD DETAIL
3" = 1'-0"
INTERIOR - HM DOOR JAMB DETAIL
3" = 1'-0"
INTERIOR - HM DOOR SILL DETAIL
12" = 1'-0"
FLAT TILE CEILING-TRACK INSTALLATION DETAIL
12" = 1'-0"
SHEETROCK CEILING-TRACK INSTALLATION DETAIL
1/4" = 1'-0"
MOUNTING HEIGHTS
1 1/2" = 1'-0"
TOP OF WALL DETAIL AT ACT
225 B.87
SIGN TYPE A
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/8
/8
/4
1/4"
9"
8 1/2"1/4"
5/8" SILK-SCREENED
BUILDING NUMBER
1" INTEGRAL TACTILE
ROOM NUMBER
TAMPER-RESISTANT END CAP
INTEGRAL BRAILLE
5/8" SILK-SCREENED TEXT
2/90 MODULAR THIN SIGN
INTEGRAL BRAILLE
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
Changing Station
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
MEN
5/8" SILK-SCREENED
ROOM NAME2
/2
/2
SIGN TYPE B
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/4
/4
/4
/4
1/4"
9"
8 1/2"1/4"
TAMPER-RESISTANT END CAP
2/90 MODULAR THIN SIGN
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
A Changing Station is available in [room # / dept name].
5/8" SILK-SCREENED
TEXT
225 B.87
SIGN TYPE C
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/8
/8
/4
1/4"
9"
8 1/2"1/4"
5/8" SILK-SCREENED
BUILDING NUMBER
1" INTEGRAL TACTILE
ROOM NUMBER
TAMPER-RESISTANT END CAP
INTEGRAL BRAILLE
5/8" SILK-SCREENED TEXT
2/90 MODULAR THIN SIGN
INTEGRAL BRAILLE
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
Changing Station
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
RESTROOM
5/8" SILK-SCREENED
ROOM NAME2
/2
/2
225 B.87
SIGN TYPE D
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/8
/8
/4
1/4"
9"
8 1/2"1/4"
5/8" SILK-SCREENED
BUILDING NUMBER
1" INTEGRAL TACTILE
ROOM NUMBER
TAMPER-RESISTANT END CAP
INTEGRAL BRAILLE
5/8" SILK-SCREENED TEXT
2/90 MODULAR THIN SIGN
INTEGRAL BRAILLE
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
Changing Station
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
WOMEN
5/8" SILK-SCREENED
ROOM NAME2
/2
/2
225 B.87
SIGN TYPE E
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/8
/8
/4
1/4"
9"
8 1/2"1/4"
5/8" SILK-SCREENED
BUILDING NUMBER
1" INTEGRAL TACTILE
ROOM NUMBER
TAMPER-RESISTANT END CAP
INTEGRAL BRAILLE
5/8" SILK-SCREENED TEXT
2/90 MODULAR THIN SIGN
INTEGRAL BRAILLE
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
Changing Station
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
FAMILY
5/8" SILK-SCREENED
ROOM NAME2
/2
/2
225 B.87
SIGN TYPE F
SERVICE SIGN - PUBLIC
2/90 PLAQUES PLUS SIGN
/8
/8
/4
1/4"
9"
8 1/2"1/4"
5/8" SILK-SCREENED
BUILDING NUMBER
1" INTEGRAL TACTILE
ROOM NUMBER
TAMPER-RESISTANT END CAP
INTEGRAL BRAILLE
2/90 MODULAR THIN SIGN
INTEGRAL BRAILLE
ADA-COMPLIANT SILK-
SCREENED PICTOGRAM
RESTROOM
5/8" SILK-SCREENED
ROOM NAME
/2
/2
M A
X H
E
IG
H T
T O
B R
A
IL
L E
2"
SIGNAGE
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:0
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
SIGNAGE SCHEDULE
A-010
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES
SHEET SPECIFIC NOTES:
5 23
1. VERIFY ALL SIGNAGE VERBIAGE WITH OWNER PRIOR TO
FABRICATION.
2. VERIFY ALL LOCATIONS FOR NEW SIGNAGE WITH OWNER
PRIOR TO FABRICATION.
3. BUILDING NUMBER TO BE VERIFIED PRIOR TO SIGN
FABRICATION.
4. ALL SIGNS SHALL BE AS MANUFACTURED BY 2/90 SIGN
SYSTEMS, OR APPROVED EQUAL.
5. SIGNS SHALL BE EQUAL TO 2/90 MODULAR THIN SIGNS OR
2/90 PLAQUES PLUS SIGNS AS NOTED.
6. FIXED AND TAMPER-RESISTANT END CAP STYLE SHALL BE
SLIMLINE.
7. ALL 2/90 PLAQUES PLUS SIGNS SHALL BE INSTALLED WITH
MANUFACTURER'S STANDARD TAPE MOUNT WITH
OPTIONAL SILASTIC BONDING.
8. ALL 2/90 MODULAR THIN SIGNS SHALL BE PROVIDED WITH
MANUFACTURER'S OPTIONAL TAMPER-RESISTANT END
CAPS AND SHALL BE INSTALLED WITH MANUFACTURER'S
STANDARD SCREW MOUNT.
9. ALL FIXED END CAPS, TAMPER-RESISTANT END CAPS AND
DIVIDER BARS SHALL BE 2/90 COLOR #150 SILVER.
10. ALL RAISED COPY ROOM NUMBERS, BRAILLE AND DIRECT-
TO-SUBSTRATE ROOM NAMES SHALL BE 2/90 COLOR #184
CHARCOAL METALLIC.
11. ALL CURVED TOP OF SIGN INSERTS SHALL BE 2/90 COLOR
#157 LEAD.
12. ALL REMAINING INSERTS SHALL BE 2/90 COLOR #221 LINEN
6" = 1'-0"
SIGNAGE TYPES
SIGNAGE SCHEDULE
ROOM NUMBER SIGN TYPE NAME ON SIGN
BUILDING 5 B5-122 C -
BUILDING 6 B6-103 B BUILDING 6 ROOM 111
BUILDING 6 B6-111 D -
BUILDING 6 B6-111 B BUILDING 61 ROOM 103
BUILDING 7 B7-103 A -
BUILDING 7 B7-104 D -
BUILDING 8 B8-110 B BUILDING 8 ROOM 125
BUILDING 8 B8-111 B BUILDING 8 ROOM 125
BUILDING 8 B8-125 D -
BUILDING 8 B8-126 B BUILDING 8 ROOM 125
BUILDING 8 B8-135 B BUILDING 8 ROOM 125
BUILDING 71 B71-149 B BUILDING 71N ROOM 105
BUILDING 71 B71-151 B BUILDING 71N ROOM 105
BUILDING 71N B71N-105 C -
BUILDING 71N B71N-106 C -
BUILDING 71N B71N-200 F -
BUILDING 71N B71N-201 B BUILDING 71N ROOM 200
BUILDING 71N B71N-211 B BUILDING 71N ROOM 200
BUILDING 71N B71N-223 B BUILDING 71N ROOM 200
BUILDING 71N B71N-226 B BUILDING 71N ROOM 200
BUILDING 86 B86-103 C -
BUILDING 86 B86-106C C, B BUILDING 86 ROOM 103
BUILDING 86 B86-111 D -
BUILDING 86 B86-113 B BUILDING 86 ROOM 103
BUILDING 86 B86-115B C, B BUILDING 86 ROOM 103
BUILDING 86 B86-121 B BUILDING 86 ROOM 103
BUILDING 86 B86-122 B BUILDING 86 ROOM 103
BUILDING 86 B86-129 E -
BUILDING 86 B86-130 B BUILDING 86 ROOM 129
BUILDING 86 B86-227 F -
BUILDING 87 B87-153 C -
1/2" = 1'-0"
TYPICAL MOUNTING
DN
DN
A-100
A-100
104 102
T-1
103 101
101A
E-1
100B 100
110 111
111A
107 108 112
116115
117A 118A 119A
ST-2
ST-3
100A
C102 C101
ST-1
A-100
UNISEX
RESTROOM
CLOSET
111A
HAC
STORAGE
(OXYGEN)
CORRIDOR
C101
02-10
EXISTING CART -
VA TO RELOCATE
EXISTING
REFRIGERATOR, VA
TO RELOCATE
02-10
02-07
MEN'S
RESTROOM
CORRIDOR
C102
INTERVIEW ROOM
10-21
UNISEX
RESTROOM
CLOSET
111A
HAC
STORAGE
(OXYGEN)
CORRIDOR
C101
10-21
10-38
B6-111
10-35 10-34
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
ST-2 107
105 110
C101
112 116
114A
115A
C102
118A
C103
121A
C104
ST-3
116A
A-100
A-100
RESTROOM
02-10
RESTROOM
10-34
10-21
10-38
517 7th street rapid city sd 57701 p 605.342.9470 f 605.342.2377 www.4front.biz
FOU
R
FRON
T
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof4FRONT PROJECT NUMBER: 15.2226.A23
/1 /2
:5
:0
P M
FOR CONSTRUCTION
15.2226.A23
NOVEMBER 13, 2020
BUILDING 5 AND 6 FIRST FLOOR
PLANS
A-100
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN VAMC
1/16" = 1'-0"
BUILDING 6 FIRST FLOOR PLAN
1/4" = 1'-0"
UNISEX RESTROOM 111 - DEMOLITION PLAN - OPTION #1
1/4" = 1'-0"
MEN'S RESTROOM 103 FLOOR PLAN
1/4" = 1'-0"
UNISEX RESTROOM 111 FLOOR PLAN - OPTION #1
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
KEYNOTES:
02-07 REMOVE/REPLACE EXISTING DOOR HARDWARE LOCK
SET. SEE SHEET A-001 FOR DOOR HARDWARE.
02-10 REMOVE EXISTING WALL MOUNTED LOCK BOX.
10-21 WALL MOUNTED ROOM SIGNAGE, SEE SHEET A-010
FOR SIGNAGE TYPE.
10-34 SURFACE MOUNTED SANITARY NAPKIN DISPENSER,
SEE SPECIFICATIONS.
10-35 SS SURFACE MOUNTED SANITARY NAPKIN DISPOSAL,
SEE SPECIFICATIONS.
10-38 SURFACE MOUNTED PLASTIC DIAPER CHANGING
STATION, HORIZONTAL TYPE, SEE SPECIFICATIONS.
5 & 6
N 1/16" = 1'-0"
BUILDING 5 FIRST FLOOR PLAN
1/4" = 1'-0"
BUILDING 5 FIRST FLOOR - RESTROOM 122 DEMO
1/4" = 1'-0"
BUILDING 5 FIRST FLOOR - RESTROOM 122
6 23
N
SHEET NOTES:
1. FURNITURE/FIXTURE SHOWN FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY EXISTING CONDITIONS FOR
CORDINATING SCOPE OF WORK.
A-101
A-101
A-101
S101
105A
119A
C103
C102
S102
E101
C101
C106
124 127A
125 126 128
132 145
S103
133 C104
C105
A-101
A-101
A-101
A-101
ST-3 107
107A 108
105 109
ST-2
C103
C102 117
117A
117B
E-1
ST-1
C101
E-2
113A
ST-4
A-101
ACOS OFFICE
MEN'S
RESTROOM
WOMEN'S
RESTROOM
OFFICE
CORRIDOR
C103
02-20
02-20
10-21
10-21
ACOS OFFICE
MEN'S
RESTROOM
WOMEN'S
RESTROOM
OFFICE
CORRIDOR
C103
10-34
02-34
02-30
02-21
02-21
02-30
WOMEN'S
RESTROOM
MEN'S
RESTROOM
HAC
MEETING ROOM
02-02
10-21
10-21
10-30
10-38
10-30
WOMEN'S
RESTROOM
MEN'S
RESTROOM
MEETING ROOM
HAC
10-32
10-39
10-35
02-21
WOMEN'S
RESTROOM
MEN'S
RESTROOM
CORRIDOR
C10502-20 10-2110-21
CORRIDOR
C105
MEN'S
RESTROOM
WOMEN'S
RESTROOM
UNISEX
RESTROOM
VESTIBULE
10-21
10-34
UNISEX
RESTROOM
VESTIBULE
10-35
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:1
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 7 AND 8 FIRST FLOOR PLANS
A-101
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 7 23
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
KEYNOTES:
02-02 REMOVE PORTION OF EXISTING WALL FOR NEW
RECESSED DIAPER CHANGING STATION, SEE
SPECIFICATIONS.
02-20 EXISTING ROOM SIGNAGE TO REMAIN.
02-21 REMOVE EXISTING WALL MOUNTED ROOM SIGNAGE.
02-30 REMOVE AND RELOCATE EXISTING SURFACE
MOUNTED PAPER TOWEL DISPENSER, SEE ROOM
FLOOR PLAN.
02-34 REMOVE AND RELOCATE EXISTING SANITARY NAPKIN
DISPENSER, SEE ROOM FLOOR PLAN.
10-21 WALL MOUNTED ROOM SIGNAGE, SEE SHEET A-010
FOR SIGNAGE TYPE.
10-30 EXISTING RELOCATED SURFACE MOUNTED PAPER
TOWEL DISPENSER.
10-32 EXISTING RELOCATED SURFACE MOUNTED SANITARY
NAPKIN DISPENER.
10-34 SURFACE MOUNTED SANITARY NAPKIN DISPENSER,
SEE SPECIFICATIONS.
10-35 SS SURFACE MOUNTED SANITARY NAPKIN DISPOSAL,
SEE SPECIFICATIONS.
10-38 SURFACE MOUNTED PLASTIC DIAPER CHANGING
STATION, HORIZONTAL TYPE, SEE SPECIFICATIONS.
10-39 RECESSED SS DIAPER CHANGING STATION,
HORIZONTAL TYPE, SEE SPECIFICATIONS.
1/16" = 1'-0"
BUILDING 8 FIRST FLOOR PLAN
1/16" = 1'-0"
BUILDING 7 FIRST FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 110 & 111 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 110 & 111 FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 103 & 104 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 103 & 104 FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 125 & 126 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 125 & 126 FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 135 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 135 FLOOR PLAN
PLACE EXISTING PAPER
TOWEL DISPENSER
NEXT TO EXISTING
MIRROR.
7,8
N N
SHEET NOTES:
1. FURNITURE/FIXTURE SHOWN FOR REFERENCE ONLY.
A-102
169 168
166B
166A
C104
E-2
162162A161
ST-3
C105
156155
155B
155A153
C101 C102
152150148
C103
A-102
334A
333A
331A
330A
342343
ST-24
C310A
316A
318A
319A
348 320 321 323323A
E-2
324A
322A
ST-3
A-102
A-102
A-102
A-102
MEN'S
RESTROOM
WOMEN'S
RESTROOM
02-20 02-20 10-21 10-21
MEN'S
RESTROOM
WOMEN'S
RESTROOM
EXISTING
LIFT RAIL
10-23
PATIENT ROOM
8' - 8"
10-24
EXISTING LIFT RAIL
10-23
BARIATRIC
PATIENT ROOM
RESTROOM
323A
8' - 8"
10-24
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
EXISTING
LIFT RAIL
02-24
PATIENT ROOM
8' - 8"
EXISTING LIFT RAIL
BARIATRIC
PATIENT ROOM
RESTROOM
323A
8' - 8"
02-24
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:1
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 71 FIRST AND THIRD FLOOR
PLANS
A-102
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 8 23
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
SHEET SPECIFIC NOTES:
KEYNOTES:
02-20 EXISTING ROOM SIGNAGE TO REMAIN.
02-24 REMOVE EXISTING PRIVACY CURTAIN. TRACK SYSTEM
TO REMAIN.
10-21 WALL MOUNTED ROOM SIGNAGE, SEE SHEET A-010
FOR SIGNAGE TYPE.
10-23 NEW PRIVACY CURTAIN AND TRACK SYSTEM, SEE
SPECIFICATIONS.
10-24 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
PRIVACY CURTAIN, SEE SPECIFICATIONS.
1. ALL PRIVACY CURTAIN TRACKS SHALL BE INSTALLED /
ATTACHED TO CEILING GRID METAL.
2. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOM SHOWN ON THIS SHEET. SEE
SPECIFICATIONS.
3. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOMS WHERE A NEW PRIVACY
CURTAIN TO BE PROVIDED. SEE SPECIFICATIONS.
4. CEILING FIXTURES SHOWN FOR REFERENCE ONLY. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS OF FIXTURES WITH NEW CURTAIN
LOCATIONS
5. ALL EXISTING PRIVACY CURTAIN TRACK AND LIFT RAIL
LOCATIONS SHOWN ON THIS SHEET IS FOR
REPRESENTING INTENT OF SCOPE AND SHALL BE
ADJUSTED / MODIFIED TO WORK WITH EXISTING CEILING
CONDITIONS AND COORDINATED WITH THE COR. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS AND PRIVACY CURTAIN
CONDITIONS PRIOR TO WORK IN SHEET SPECIFIC ROOM.
6. ADJUST PRIVACY CURTAIN SYSTEM TO WORK WITH
EXISTING CEILING FIXTURE CONDITIONS.
7. CEILING HEIGHTS SHOWN FOR REFERENCE ONLY.
CONTRACTOR SHALL VERIFY EXISTING CEILING HEIGHTS
FOR PRIVACY CURTAIN SIZE.
8. FURNITURE/FIXTURES SHOWN FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY EXISTING CONDITIONS FOR
CORDINATING SCOPE OF WORK.
1/16" = 1'-0"
BUILDING 71 FIRST FLOOR PLAN
1/16" = 1'-0"
BUILDING 71 THIRD FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 149 & 151 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 149 & 151 FLOOR PLAN
1/4" = 1'-0"
PATIENT 319 REFLECTED CEILING PLAN
1/4" = 1'-0"
BARIATRIC PATIENT 323 REFLECTED CEILING PLAN
N N
1/4" = 1'-0"
PATIENT 319 REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0"
BARIATRIC PATIENT 323 REFLECTED CEILING DEMOLITION PLAN
A-103
334A
333A
331A
330A
342343
ST-24
C310A
316A
318A
319A
348 320 321 323323A
E-2
324A
322A
ST-3
A-103
4 A-103
A-103
A-103
A-103
RESTROOM
RESTROOM
3' - 0"
10-34
RESTROOM
RESTROOM
EXISTING
LIFT RAIL
10-23
PATIENT ROOM
ANTER
RESTROOM
316A
8' - 8"
10-24
EXISTING
LIFT RAIL
10-23
PATIENT ROOM
RESTROOM
318A
8' - 8"
10-24
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
EXISTING
LIFT RAIL
PATIENT ROOM
ANTER
RESTROOM
316A
8' - 8"
02-24
EXISTING
LIFT RAIL
PATIENT ROOM
RESTROOM
318A
8' - 8"
02-24
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:1
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 71 THIRD FLOOR PLANS
A-103
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 9 23
GENERAL NOTES:
KEYNOTES:
02-24 REMOVE EXISTING PRIVACY CURTAIN. TRACK SYSTEM
TO REMAIN.
10-23 NEW PRIVACY CURTAIN AND TRACK SYSTEM, SEE
SPECIFICATIONS.
10-24 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
PRIVACY CURTAIN, SEE SPECIFICATIONS.
10-34 SURFACE MOUNTED SANITARY NAPKIN DISPENSER,
SEE SPECIFICATIONS.
1/16" = 1'-0"
BUILDING 71 THIRD FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 345 & 346 DEMOLITION PLAN
1/4" = 1'-0"
RESTROOMS 345 & 346 FLOOR PLAN
1/4" = 1'-0"
PATIENT 316 REFLECTED CEILING PLAN
1/4" = 1'-0"
PATIENT 318 REFLECTED CEILING PLAN
N
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
1/4" = 1'-0"
PATIENT 316 REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0"
PATIENT 318 REFLECTED CEILING DEMOLITION PLAN
SHEET SPECIFIC NOTES:
1. ALL PRIVACY CURTAIN TRACKS SHALL BE INSTALLED /
ATTACHED TO CEILING GRID METAL.
2. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOM SHOWN ON THIS SHEET. SEE
SPECIFICATIONS.
3. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOMS WHERE A NEW PRIVACY
CURTAIN TO BE PROVIDED. SEE SPECIFICATIONS.
4. CEILING FIXTURES SHOWN FOR REFERENCE ONLY. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS OF FIXTURES WITH NEW CURTAIN
LOCATIONS
5. ALL EXISTING PRIVACY CURTAIN TRACK AND LIFT RAIL
LOCATIONS SHOWN ON THIS SHEET IS FOR
REPRESENTING INTENT OF SCOPE AND SHALL BE
ADJUSTED / MODIFIED TO WORK WITH EXISTING CEILING
CONDITIONS AND COORDINATED WITH THE COR. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS AND PRIVACY CURTAIN
CONDITIONS PRIOR TO WORK IN SHEET SPECIFIC ROOM.
6. ADJUST PRIVACY CURTAIN SYSTEM TO WORK WITH
EXISTING CEILING FIXTURE CONDITIONS.
7. CEILING HEIGHTS SHOWN FOR REFERENCE ONLY.
CONTRACTOR SHALL VERIFY EXISTING CEILING HEIGHTS
FOR PRIVACY CURTAIN SIZE.
8. FURNITURE/FIXTURES SHOWN FOR REFERENCE ONLY.
334A
333A
331A
330A
342343
ST-24
C310A
316A
318A
319A
348 320 321 323323A
E-2
324A
322A
ST-3
A-104
A-104
A-104
A-104
A-104
A-104
10-23
EXISTING
LIFT RAIL
RESTROOM
330A
PATIENT ROOM
8' - 8"
10-24
10-23
10-23
EXISTING LIFT RAILEXISTING LIFT RAIL
PATIENT ROOM
RESTROOM
322A
PATIENT ROOM
RESTROOM
324A
8' - 8" 10-24
8' - 8"
10-24
10-23
10-23
EXISTING
RAIL LIFT
EXISTING
LIFT RAIL
PATIENT ROOM
PATIENT ROOM
RESTROOM
333A
RESTROOM
334A
8' - 8" 8' - 8"
10-24 10-24
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
EXISTING
LIFT RAIL
RESTROOM
330A
PATIENT ROOM
8' - 8"
02-24
EXISTING LIFT RAILEXISTING LIFT RAIL
PATIENT ROOM
RESTROOM
322A
PATIENT ROOM
RESTROOM
324A
8' - 8" 02-24
8' - 8"
02-24
EXISTING
RAIL LIFT
EXISTING
LIFT RAIL
PATIENT ROOM
PATIENT ROOM
RESTROOM
333A
RESTROOM
334A
8' - 8" 8' - 8"
02-24 02-24
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:2
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 71 THIRD FLOOR PLANS
A-104
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 10 23
GENERAL NOTES:
KEYNOTES:
02-24 REMOVE EXISTING PRIVACY CURTAIN. TRACK SYSTEM
TO REMAIN.
10-23 NEW PRIVACY CURTAIN AND TRACK SYSTEM, SEE
SPECIFICATIONS.
10-24 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
PRIVACY CURTAIN, SEE SPECIFICATIONS.
1/16" = 1'-0"
BUILDING 71 THIRD FLOOR PLAN
1/4" = 1'-0"
PATIENT 330 REFLECTED CEILING PLAN
1/4" = 1'-0"
PATIENT 322 & 324 REFLECTED CEILING PLANS
1/4" = 1'-0"
PATIENT 333 & 334 REFLECTED CEILING PLAN
N
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
1/4" = 1'-0"
PATIENT 330 REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0"
PATIENT 322 & 324 REFLECTED CEILING DEMOLITION PLANS
1/4" = 1'-0"
PATIENT 333 & 334 REFLECTED CEILING DEMOLITION PLAN
SHEET SPECIFIC NOTES:
1. ALL PRIVACY CURTAIN TRACKS SHALL BE INSTALLED /
ATTACHED TO CEILING GRID METAL.
2. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOM SHOWN ON THIS SHEET. SEE
SPECIFICATIONS.
3. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOMS WHERE A NEW PRIVACY
CURTAIN TO BE PROVIDED. SEE SPECIFICATIONS.
4. CEILING FIXTURES SHOWN FOR REFERENCE ONLY. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS OF FIXTURES WITH NEW CURTAIN
LOCATIONS
5. ALL EXISTING PRIVACY CURTAIN TRACK AND LIFT RAIL
LOCATIONS SHOWN ON THIS SHEET IS FOR
REPRESENTING INTENT OF SCOPE AND SHALL BE
ADJUSTED / MODIFIED TO WORK WITH EXISTING CEILING
CONDITIONS AND COORDINATED WITH THE COR. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS AND PRIVACY CURTAIN
CONDITIONS PRIOR TO WORK IN SHEET SPECIFIC ROOM.
6. ADJUST PRIVACY CURTAIN SYSTEM TO WORK WITH
EXISTING CEILING FIXTURE CONDITIONS.
7. CEILING HEIGHTS SHOWN FOR REFERENCE ONLY.
CONTRACTOR SHALL VERIFY EXISTING CEILING HEIGHTS
FOR PRIVACY CURTAIN SIZE.
8. FURNITURE/FIXTURES SHOWN FOR REFERENCE ONLY.
A-105
3A-105
A-105
A-105
S102
112E
112D
112F
112A 112C
112G
112B
108C
108B
109A 109B
C112
104B
C106
105 S101
140B
146A
140A
141A
139137
138 140
E-1
129A
133A109110
128A119
123 124 125 126129B
113B
113A
C113 C108
C111
C110
C109
A-105
A-105
A-105
A-105
UNISEX
RESTROOM
UNISEX
RESTROOM
CORRIDOR
C106
02-21
02-21
10-21
10-21
UNISEX
RESTROOM
UNISEX
RESTROOM
CORRIDOR
C106
EXAM
EXAM
WOMEN'S
HEALTH EXAM
EXAM
CORRIDOR
C111
DESK 2'-6" X 4'-0"
DESK 2'-6" X 4'-0"
DESK 2'-6" X 4'-0"
DESK 2'-6" X 4'-0"
EXAM TABLE
2'-5" X 4'-6"
EXAM TABLE
2'-5" X 4'-6"
RHEUMATOLOGIST
WAITING
104B
EXISTING DESKREFRIGERATORCHAIR
EXAM TABLE
CART
SINK AND
CABINET 10-23
10-23
10-23
10-23
EXAM
EXAM
WOMEN'S
HEALTH EXAM
EXAM
CORRIDOR
C111
10-24
10-24
10-24
10-24
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
RHEUMATOLOGIST
WAITING
104B
10-23
EXIST. ACT
VERIFY
02-23
02-23
02-23
EXAM
EXAM
WOMEN'S
HEALTH EXAM
EXAM
CORRIDOR
C111
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
EXISTING ACT
VERIFY
02-2402-24
02-2402-24
02-23
02-23
RHEUMATOLOGIST
WAITING
104B
EXIST. ACT
VERIFY
02-23
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:2
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 71N FIRST FLOOR PLANS
A-105
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 11 23
GENERAL NOTES:
KEYNOTES:
02-21 REMOVE EXISTING WALL MOUNTED ROOM SIGNAGE.
02-23 REMOVE AND RELOCATE EXISTING PRIVACY CURTAIN
AND TRACK SYSTEM, SEE ROOM REFLECTED CEILING
PLAN.
02-24 REMOVE EXISTING PRIVACY CURTAIN. TRACK SYSTEM
TO REMAIN.
10-21 WALL MOUNTED ROOM SIGNAGE, SEE SHEET A-010
FOR SIGNAGE TYPE.
10-23 NEW PRIVACY CURTAIN AND TRACK SYSTEM, SEE
SPECIFICATIONS.
10-24 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
PRIVACY CURTAIN, SEE SPECIFICATIONS.
1/16" = 1'-0"
BUILDING 71N FIRST FLOOR PLAN
1/4" = 1'-0"
RESTROOMS 105 & 106 DEMOLITION PLANS
1/4" = 1'-0"
RESTROOMS 105 & 106 FLOOR PLANS
1/4" = 1'-0"
EXAM ROOMS 114, 116, 118 & 119 FLOOR PLANS
1/4" = 1'-0"
RHEUMATOLOGIST 103 FLOOR PLAN
1/4" = 1'-0"
EXAM ROOMS 114, 116, 118 & 119 REFLECTED CEILING PLANS
71N
1/4" = 1'-0"
RHEUMATOLOGIST 103 REFLECTED CEILING PLAN
N
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
1/4" = 1'-0"
EXAM ROOMS 114, 116, 118 & 119 DEMOLITION PLANS
1/4" = 1'-0"
RHEUMATOLOGIST 103 REFLECTED CEILING DEMOLITION PLAN
SHEET SPECIFIC NOTES:
1. ALL PRIVACY CURTAIN TRACKS SHALL BE INSTALLED /
ATTACHED TO CEILING GRID METAL.
2. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOM SHOWN ON THIS SHEET. SEE
SPECIFICATIONS.
3. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOMS WHERE A NEW PRIVACY
CURTAIN TO BE PROVIDED. SEE SPECIFICATIONS.
4. CEILING FIXTURES SHOWN FOR REFERENCE ONLY. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS OF FIXTURES WITH NEW CURTAIN
LOCATIONS
5. ALL EXISTING PRIVACY CURTAIN TRACK AND LIFT RAIL
LOCATIONS SHOWN ON THIS SHEET IS FOR
REPRESENTING INTENT OF SCOPE AND SHALL BE
ADJUSTED / MODIFIED TO WORK WITH EXISTING CEILING
CONDITIONS AND COORDINATED WITH THE COR. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS AND PRIVACY CURTAIN
CONDITIONS PRIOR TO WORK IN SHEET SPECIFIC ROOM.
6. ADJUST PRIVACY CURTAIN SYSTEM TO WORK WITH
EXISTING CEILING FIXTURE CONDITIONS.
7. CEILING HEIGHTS SHOWN FOR REFERENCE ONLY.
CONTRACTOR SHALL VERIFY EXISTING CEILING HEIGHTS
FOR PRIVACY CURTAIN SIZE.
8. FURNITURE/FIXTURES SHOWN FOR REFERENCE ONLY.
A-106
A-106
A-106
S102
112D
112E
112F
112A 112C
C113
113B
113A
112B 108
108C
107108B
112G
109A 109B
C112
C106
104B
S101
140B
146A
140A
139137
138E-1
129A
125124123122
C110
128A
110 109 133A
C108
C111
C109
A-106
A-106
A-106
A-106
A-106
A-106
A-106
PROCEDURE
PROCEDURE
CORRIDOR
C109
10-23
10-23
EXISTING LIFT
RAIL
PROCEDURE
PROCEDURE
CORRIDOR
C109
EXIST. ACT
VERIFY
10-24
10-24
EXAM
URGENT CARE
EXAM
CORRIDOR
C109
CLOSET
131A
M3AM3A
B71N-131A 10-22
10-23
10-23
10-23
EXISTING
LIFT RAIL
EXISTING
LIFT RAIL
EXAM
URGENT CARE
EXAM
CORRIDOR
C109
EXISTING DOOR
PRIVACY CURTAIN
EXISTING DOOR
PRIVACY CURTAIN
REPLACE EXISTING
CURTAIN WITH
LONGER PRIVACY
CURTAIN
10-25
10-24
EXIST. ACT
VERIFY
EXIST. ACT
VERIFY 9' - 0"
M3A
M3A
MOVE EXISTING DESK TO FIT
OUTSIDE OF NEW PRIVACY CURTAIN
LOCATION
PROVIDER/
VASCULAR
STUDIES
10-23
PROVIDER/
VASCULAR
STUDIES
10-24
EXIST. ACT
VERIFY
EXISTING DOORS TO REMAIN
SHOWN AT 45° WITH SOLID LINE
ITEMS TO BE DEMOLISHED, SEE
KEYNOTES
PLAN LEGEND
EXISTING 2'X4' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING 2'X2' ACT CEILING
SYSTEM TO REMAIN UNLESS
OTHERWISE NOTED
EXISTING GYPSUM BOARD
CEILING/SOFFIT TO REMAIN
UNLESS OTHERWISE NOTED
EXISTING BULKHEAD TO REMAIN
UNLESS OTHERWISE NOTED
NEW GYPSUM BOARD CEILING
CEILING HEIGHTHEIGHT
EXAM
URGENT CARE
EXAM
CORRIDOR
C109
02-22
02-24
EXISTING
LIFT RAIL
EXISTING
LIFT RAIL
EXAM
URGENT CARE
EXAM
CORRIDOR
C109
EXISTING DOOR
PRIVACY CURTAIN
EXISTING DOOR
PRIVACY CURTAIN
02-24
EXIST. ACT
VERIFY
EXIST. ACT
VERIFY
02-09
EXISTING LIFT
RAIL
PROCEDURE
PROCEDURE
CORRIDOR
C109
EXIST. ACT
VERIFY
02-24
02-24
PROVIDER/
VASCULAR
STUDIES
EXIST. ACT
VERIFY
02-23
02-24
517 7th street Rapid City SD 57701 p 605.342.9470 f 605.342.2377 www.fourfrontdesign.com
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of Veterans Affairsof
666-19-104
/1 /2
:5
:3
P M
FOR CONSTRUCTION
NOVEMBER 13, 2020
BUILDING 71N FIRST FLOOR PLANS
A-106
VETERAN'S HEALTH -
PRIVACY AND DECENCY
JEJL
SHERIDAN, WYOMING
SHERIDAN
VAMC
15.2226.A23 12 23
GENERAL NOTES:
KEYNOTES:
02-09 REMOVE PORTION OF EXISTING CEILING ACT PANEL
AND GRID FOR NEW WALL.
02-22 REMOVE/REPLACE EXISTING SINK WITH NEW SINK
FIXTURES. SEE SPECIFICATIONS.
02-23 REMOVE AND RELOCATE EXISTING PRIVACY CURTAIN
AND TRACK SYSTEM, SEE ROOM REFLECTED CEILING
PLAN.
02-24 REMOVE EXISTING PRIVACY CURTAIN. TRACK SYSTEM
TO REMAIN.
10-22 NEW LAVATORY AND FAUCET FIXTURE. CONNECT TO
EXISTING PLUMBING IN WALL. PROVIDE ADDITIONAL
PLUMBING AND BLOCKING FOR NEW FIXTURE. SEE
SPECIFICATIONS.
10-23 NEW PRIVACY CURTAIN AND TRACK SYSTEM, SEE
SPECIFICATIONS.
10-24 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
PRIVACY CURTAIN, SEE SPECIFICATIONS.
10-25 EXISTING TRACK SYSTEM TO REMAIN. PROVIDE NEW
MENTAL HEALTH TYPE PRIVAY CURTAIN. SEE
SPECIFICATIONS.
1/16" = 1'-0"
BUILDING 71N FIRST FLOOR PLAN
1/4" = 1'-0"
PROCEDURE 126 & 127 FLOOR PLAN
1/4" = 1'-0"
PROCEDURE 126 & 127 REFLECTED CEILING PLAN
1/4" = 1'-0"
EXAM ROOMS 128 & 131 FLOOR PLAN
1/4" = 1'-0"
EXAM ROOMS 128 & 131 REFLECTED CEILING PLAN
1/4" = 1'-0"
VASCULAR STUDIES 132 FLOOR PLAN
1/4" = 1'-0"
VASCULAR STUDIES 132 REFLECTED CEILING PLAN
71N
N
1. SHEET SIZE FOR PROPER SCALE IS 30"X42", HOWEVER
CONTRACTOR SHALL NOT SCALE DRAWINGS BUT SHALL
REQUEST THE DESIRED DIMENSIONS FROM THE
ARCHITECT.
2. SEE SHEET G-001 FOR PROJECT NOTES.
1/4" = 1'-0"
EXAM ROOMS 128 & 131 DEMOLITION FLOOR PLAN
1/4" = 1'-0"
EXAM ROOMS 128 & 131 REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0"
PROCEDURE 126 & 127 REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0"
VASCULAR STUDIES 132 REFLECTED CEILING DEMOLITION PLAN
SHEET SPECIFIC NOTES:
1. ALL PRIVACY CURTAIN TRACKS SHALL BE INSTALLED /
ATTACHED TO CEILING GRID METAL.
2. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOM SHOWN ON THIS SHEET. SEE
SPECIFICATIONS.
3. REMOVE AND REPLACE PRIVACY CURTAIN AND CHAIN /
HOOK SYSTEM AT ALL ROOMS WHERE A NEW PRIVACY
CURTAIN TO BE PROVIDED. SEE SPECIFICATIONS.
4. CEILING FIXTURES SHOWN FOR REFERENCE ONLY. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING CONDITIONS OF FIXTURES WITH NEW CURTAIN
LOCATIONS
5. ALL EXISTING PRIVACY CURTAIN TRACK AND LIFT RAIL
LOCATION…