S02 Drawings 531-24-108 Upgrade Storm Sewer.pdf

PDF 8 MB Posted

Attached to
Y1ND--531-24-108 | UPGRADE STORM SEWER SYSTEM
Solicitation number
36C26025R0035
Issued by

About this file

This is a set of engineering drawings and specifications for a storm sewer system upgrade project at the Boise VA Medical Center (Project #531-24-108). The drawings detail the installation of new storm drainage infrastructure including catch basins, sediment traps, seepage beds, and associated piping across multiple locations including Parking Lots 1B and 10, as well as the Parade Field area.

The plans include civil site plans, drainage details, plumbing plans, and technical specifications for the storm sewer upgrades. Key components include sediment control catch basins with specified elevations, storm line installations with pipe sizes ranging from 6" to 24", inlet protection systems, MC-4500 infiltration chambers, and detailed requirements for backfill materials and installation methods. The drawings provide comprehensive construction details including pipe penetrations, manhole specifications, tree protection measures, and pavement restoration requirements. Sheet C0.0 shows the overall site plan, while subsequent sheets provide detailed plan views, sections, and specifications for each project area.

View the file

Other files

File Type Posted
Site Visit Roster and RFI.pdf PDF
36C26025R0035 0001.docx DOCX document
S02 EXHIBIT B Past Performance Reference Form.docx DOCX document
36C26025R0035_2.docx DOCX document
S02 Exhibit A Project Information Sheet for Contractors.docx DOCX document
S02 Specifications 531-24-108 Upgrade Storm Sewer.pdf PDF
S02 Wage Determination ID20250104_01-03-2025.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ethoscivil.com info@ethoscivil.com 253.414.1989

SITE

LEGEND

WV

12/04/2024

X

X

X

X

X

WV

X ethoscivil.com info@ethoscivil.com 253.414.1989

48" 36"

24"

NOTES:

1. FILTERS SHALL BE INSPECTED AFTER EACH STORM EVENT AND

CLEANED OR REPLACED WHEN 1/3 FULL.

2. INSTALL INLET PROTECTION IN ALL NEW STORM STRUCTURES THAT

WILL COLLECT STORMWATER AS THEY ARE INSTALLED.

ADAPTOR SKIRT RETRIEVAL STRAP

OVERFLOW (TO BYPASS

PEAK STORM VOLUMES)

EXISTING

CATCH BASIN

GEOTEXTILE

FABRIC

SEDIMENT ACCUMULATION

WV

NOTE:

1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS.

2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING.

3. THE RECTANGULAR FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR

DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION.

4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE

A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE.

AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR.

SEPARATE BASE

PRECAST

INTEGRAL BASE

PRECAST WITH RISER

48"

12"

6"

MORTAR (TYP)

6" GRAVEL BACKFILL FOR

PIPE ZONE BEDDING

UPTURNED ELBOW AT

NORTH INLET. TOP OF

UPTURNED ELBOW SHALL BE

MINIMUM 6" ABOVE TOP OF

SEEPAGE BED ELEVATION

OR ELEV: -7.14'

OUTLET TO NEW SEEPAGE

BED

NOTES:

1. SEEPAGE BED DIMENSIONS ARE AT THE BOTTOM OF TRENCH.

2. CONTRACTOR SHALL FIELD SURVEY TO VERIFY THE TOP OF THE

SEEPAGE BED IS 6" BELOW THE TOP OF THE UPTURNED ELBOW

SHOWN IN DETAIL 2. FINAL DEPTH IS CONTROLLED BY

MAINTAINING A 2.18% PIPE SLOPE AND MINIMUM 12" VERTICAL

SEPARATION ATTHE UTILITY CROSSING WITH SEWER NOTED ON

THE PLAN.

30'

8" SOLID WALL PVC SDR-35

END CAP, TYP.

OBSERVATION WELL WITH

LOCKING LID.

(14) 12"DIA PERFORATED

DISTRIBUTION PIPES @ 24" O.C.

CLEAN 1-1/2" TO

2" DRAIN ROCK

STORMWATER FROM

SEDIMENT TRAP

CATCH BASIN

OBSERVATION WELL WITH

LOCKING LID.

(14) 12"DIA PERFORATED PVC

DISTRIBUTION PIPES @ 24" O.C.

CLEAN 1-1/2" TO

2" DRAIN ROCK

6.

5'

2'

4 OZ/SY GEOTEXTILE (NONWOVEN)

AROUND TOP AND SIDES.

MIN. 18" OVERLAP.

RESTORE GROUND SURFACE

TO MATCH EXISTING

1' MIN.

.3

3'

6.

1.5'

ASTM C33 SAND LAYER REQUIRED IF

GROUNDWATER IS ENCOUNTERED.

SECTIONSECTION

SUBGRADE SHALL BE PREPARED

PER ITD STD. SPEC. 205.03.G

ASPHALT FINISHED SECTION PER ITD

STD. SPEC. SECTION 702

MATCH EXISTING

CRUSHED SURFACING BASE COURSE

PER ITD STD. SPEC. 409.03.E

NOTES:

1. MATCH EXISTING ASPHALT, BASE COURSE, AND SUBBASE

THICKNESSES.

2. HMA SHALL BE COMPACTED TO A TARGET AVERAGE DENSITY OF

92% BASED ON THE RICE THEORETICAL MAXIMUM DENSITY PER

ASTM D-2041. INDIVIDUAL LOCATIONS SHALL BE COMPACTED

NOT LESS THAN 90% NOR MORE THAN 96%.

3. ALL ASPHALT BASE MATERIAL SHALL BE COMPACTED TO A

MINIMUM DENSITY OF 95% BASED ON THE MODIFIED PROCTOR

MAXIMUM DRY DENSITY PER ASTM D-1557.

4. SUBGRADE SHALL BE COMPACTED TO A FIRM AND UNYIELDING

CONDITION PRIOR TO PLACEMENT OF ANY PAVEMENT LAYERS.

ANY LOCALIZED ZONES OF SOFT, ORGANIC-RICH, OR

DEBRIS-LADEN SOILS SHOULD BE OVEREXCAVATED AND

REPLACED WITH STRUCTURAL FILL MATERIAL.

5. RECYCLED CONCRETE IS NOT ACCEPTABLE.

6. SEAL JOINTS WITH EMULSIFIED ASPHALT PER PROJECT

SPECIFICATIONS.

STRUCTURAL SUBBASE PER

ISPWC STD. SPEC. 801, TABLE 1

NOTE

CONSTRUCTION SHALL

CONFORM TO ISPWC

SPEC. 703

FINISH GROUND GRADE

TOP OF CURB

AT APPROACH

PAVEMENT 6"

5-1/2"

1'- 4"

7-3/4"

1/2"

1" R

FINISHED GRADE

OF PAVEMENT

BACKFILL WITH 3500 PSI

CEMENT CONCRETE

6"Ø SCH 40 STEEL PIPE

PAINTED YELLOW, FILLED

WITH CONCRETE AND

CROWNED FOR DRAINAGE3'

3'

3" MIN 1.5' (MIN)

REINSTALL

SALVAGED SIGNS

ON NEW SIGN POST

2" DIA SCHEDULE 40

GALVANIZED METAL PIPE

2 X ROOTBALL

DIAMETER MIN.

NOTES:

1. WIRE BASKETS WILL BE REMOVED COMPLETELY PRIOR TO COMPLETION OF BACKFILLING.

2.

3.

4. STAKE ALL TREES.

5. DO NOT CUT OR DAMAGE LEADER. PRUNE DAMAGED WOOD IMMEDIATELY PRIOR TO PLANTING.

6. DO NOT BUILD WATER RETAINING BERM AROUND TREES PLANTED IN IRRIGATED TURF AREAS.

7. TREES PLANTED IN NATURAL AREAS WITH TREE DRIP RINGS, SHALL HAVE WATER RETAINING BERMS.

PROTECTION CAPS ON ALL POSTS.

6' STEEL T-POST 4' EXPOSED, MIN. 3 PER TREE

SET ROOTBALL 1" HIGHER THAN FINISH GRADE

3" DEEP MULCH

STAKE TO EXTEND 24" INTO UNDISTURBED SOIL.

UNDISTURBED SUBGRADE.

HOLE SHOULD HAVE ROUGHENED SIDES.

FINISH GRADE

WEED MAT

ANY BROKEN OR CRUMBLING ROOTBALLS WILL BE REJECTED. REMOVING THE WIRE WILL NOT BE AN

EXCUSE FOR DAMAGED ROOTBALLS.

CUT AND REMOVE BURLAP FROM ROOTBALL. REMOVE ALL TWINE AND PLASTIC. IF TREE IS IN FIBER POT, REMOVE PRIOR TO PLANTING.

REMOVE GUY WIRE AFTER ONE GROWING

SEASON.

12 GAUGE GALVANIZED WIRE. DOUBLE STRAND,

TWISTED WITH FLAGGING.

WATER RETAINING BERM INSTALL AT EDGE OF

PLANTING PIT, NO BERM IN IRRIGATED TURF AREAS.

BACKFILL WITH APPROVED TOPSOIL/PLANTING

MEDIUM. REMOVE ALL DEBRIS.

MC-4500 TECHNICAL SPECIFICATIONS

PART # STUB B C

MC4500IEPP06T 6" (150 mm)

42.54" (1081 mm) --- MC4500IEPP06B --- 0.86" (22 mm) MC4500IEPP08T 8" (200 mm)

40.50" (1029 mm) --- MC4500IEPP08B --- 1.01" (26 mm) MC4500IEPP10T 10" (250 mm)

38.37" (975 mm) --- MC4500IEPP10B --- 1.33" (34 mm) MC4500IEPP12T 12" (300 mm)

35.69" (907 mm) --- MC4500IEPP12B --- 1.55" (39 mm) MC4500IEPP15T 15" (375 mm)

32.72" (831 mm) --- MC4500IEPP15B --- 1.70" (43 mm)

MC4500IEPP18T

18" (450 mm) 29.36" (746 mm) ---

MC4500IEPP18TW

MC4500IEPP18B

--- 1.97" (50 mm)

MC4500IEPP18BW

MC4500IEPP24T

24" (600 mm) 23.05" (585 mm) ---

MC4500IEPP24TW

MC4500IEPP24B

--- 2.26" (57 mm)

MC4500IEPP24BW

MC4500IEPP30BW 30" (750 mm) --- 2.95" (75 mm) MC4500IEPP36BW 36" (900 mm) --- 3.25" (83 mm) MC4500IEPP42BW 42" (1050 mm) --- 3.55" (90 mm)

NOTE: ALL DIMENSIONS ARE NOMINAL

NOMINAL CHAMBER SPECIFICATIONS

SIZE (W X H X INSTALLED LENGTH) 100.0" X 60.0" X 48.3" (2540 mm X 1524 mm X 1227 mm) CHAMBER STORAGE 106.5 CUBIC FEET (3.01 m³) MINIMUM INSTALLED STORAGE* 162.6 CUBIC FEET (4.60 m³) WEIGHT (NOMINAL) 125.0 lbs. (56.7 kg)

NOMINAL END CAP SPECIFICATIONS

SIZE (W X H X INSTALLED LENGTH) 90.0" X 61.0" X 32.8" (2286 mm X 1549 mm X 833 mm) END CAP STORAGE 39.5 CUBIC FEET (1.12 m³) MINIMUM INSTALLED STORAGE* 115.3 CUBIC FEET (3.26 m³) WEIGHT (NOMINAL) 90 lbs. (40.8 kg)

*ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY.

PARTIAL CUT HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"

PARTIAL CUT HOLES AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"

END CAPS WITH A PREFABRICATED WELDED STUB END WITH "W"

B

C

52.0" (1321 mm)

48.3" (1227 mm)

INSTALLED

60.0" (1524 mm)

100.0" (2540 mm) 90.0" (2286 mm)

61.0" (1549 mm)

32.8" (833 mm)

INSTALLED

38.0" (965 mm)

CUSTOM PREFABRICATED INVERTS

ARE AVAILABLE UPON REQUEST.

INVENTORIED MANIFOLDS INCLUDE

12-24" (300-600 mm) SIZE ON SIZE AND 15-48" (375-1200 mm)

ECCENTRIC MANIFOLDS. CUSTOM

INVERT LOCATIONS ON THE MC-4500

END CAP CUT IN THE FIELD ARE NOT

RECOMMENDED FOR PIPE SIZES

GREATER THAN 10" (250 mm). THE

INVERT LOCATION IN COLUMN 'B'

ARE THE HIGHEST POSSIBLE FOR

THE PIPE SIZE.

UPPER JOINT

CORRUGATION

WEB

CREST

CREST

STIFFENING

RIB

VALLEY

STIFFENING RIB

BUILD ROW IN THIS

DIRECTION

LOWER JOINT

CORRUGATION

FOOT

MC-4500 ISOLATOR ROW PLUS DETAIL

SUMP DEPTH TBD BY

SITE DESIGN ENGINEER

(24" [600 mm] MIN RECOMMENDED)

CATCH BASIN

OR MANHOLE

OPTIONAL INSPECTION PORT

MC-4500 END CAP

24" (600 mm) HDPE ACCESS PIPE REQUIRED

USE FACTORY PARTIAL CUT END CAP PART #:

MC4500IEPP24BC OR MC4500RIEPP24BW

STORMTECH HIGHLY RECOMMENDS

FLEXSTORM INSERTS IN ANY UPSTREAM

STRUCTURES WITH OPEN GRATES

COVER PIPE CONNECTION TO END CAP WITH ADS

GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE

ONE LAYER OF ADSPLUS125 WOVEN GEOTEXTILE BETWEEN

FOUNDATION STONE AND CHAMBERS

10.3' (3.1 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS

ELEVATED BYPASS MANIFOLD

MC-4500 CHAMBER

INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE

PART #: MCFLAMP

MC-4500 CROSS SECTION DETAIL

ACCEPTABLE FILL MATERIALS: STORMTECH MC-4500 CHAMBER SYSTEMS

PLEASE NOTE:

1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE".

2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.

3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR

COMPACTION REQUIREMENTS.

4. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.

5. WHERE RECYCLED CONCRETE AGGREGATE IS USED IN LAYERS 'A' OR 'B' THE MATERIAL SHOULD ALSO MEET THE ACCEPTABILITY CRITERIA OUTLINED IN TECHNICAL NOTE 6.20 "RECYCLED CONCRETE STRUCTURAL BACKFILL".

NOTES:

1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION 60x101

2. MC-4500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".

3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION

FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.

4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.

5. REQUIREMENTS FOR HANDLING AND INSTALLATION:

· TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.

· TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3”.

· TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 500 LBS/FT/%.

AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.

MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL

CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT

D

FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE

TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE

PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT

PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER

ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.

CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/A

PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED

INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND

PREPARATION REQUIREMENTS.

C

INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE

TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm)

ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT

SUBBASE MAY BE A PART OF THE 'C' LAYER.

GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR

PROCESSED AGGREGATE.

MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS

LAYER.

AASHTO M145¹

A-1, A-2-4, A-3

OR

AASHTO M43¹

3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10

BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER

THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN

12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR

WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR

PROCESSED AGGREGATE MATERIALS.

B

EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS

FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER

ABOVE.

CLEAN, CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE5 AASHTO M43¹

3, 357, 4, 467, 5, 56, 57

A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE

SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE5 AASHTO M43¹

3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3

NO COMPACTION REQUIRED.

7.0' (2.1 m)

MAX

24" (600 mm) MIN*

100" (2540 mm) 12" (300 mm) MIN

ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND

CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS

12" (300 mm) MIN

12" (300 mm) MIN 9" (230 mm) MIN

D C

B

A

*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED

INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,

INCREASE COVER TO 30" (750 mm).

DEPTH OF STONE TO BE DETERMINED

BY SITE DESIGN ENGINEER 9" (230 mm) MIN

PERIMETER STONE

(SEE NOTE 4)

EXCAVATION WALL

(CAN BE SLOPED OR VERTICAL)

MC-4500

END CAP

SUBGRADE SOILS

(SEE NOTE 3)

PAVEMENT LAYER (DESIGNED

BY SITE DESIGN ENGINEER)

60" (1524 mm)

**THIS CROSS SECTION DETAIL REPRESENTS

MINIMUM REQUIREMENTS FOR INSTALLATION.

PLEASE SEE THE LAYOUT SHEET(S) FOR

PROJECT SPECIFIC REQUIREMENTS.

NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL

FOR A PROPER FIT IN END CAP OPENING.

12" (300 mm)

MIN SEPARATION

12" (300 mm) MIN INSERTION

12" (300 mm)

MIN SEPARATION

12" (300 mm)

MIN INSERTION

MC-SERIES END CAP INSERTION DETAIL

MANIFOLD HEADER

MANIFOLD STUB

STORMTECH END CAP

MANIFOLD HEADER

MANIFOLD STUB

N O

T

TO

S C

AL

E

AD

VA

N C

ED

D

R

AI

N

AG

E

SY

ST

EM

S, IN

C

"A D

S" ) H

AS

P

R

EP

AR

ED

T H

IS

D

ET

AI

L

BA

SE

D

O N

R

EF

ER

EN

C

ED

S

TA

N D

AR

D

S.

A

D S

H

AS

N O

T

PE

R

FO

R M

ED

A

N Y

EN

G

IN

EE

R

IN

G O

R D

ES

IG

N S

ER

VI

C

ES

F O

R T

H

IS

P R

O

JE

C T, N O

R H

AS

A

D S

IN

D

EP

EN

D

EN

TL

Y

VE

R

IF

IE

D T

H E

IN

FO

R M

AT

IO

N S

U

PP

LI

ED

. T H

E

IN

ST

AL

LA

TI

O N

D

ET

AI

LS

P R

O

VI

D

ED

H

ER

EI

N

A R

E G

EN

ER

AL

R

EC

O

M M

EN

D

AT

IO

N S

AN

D

A R

E N

O T

SP

EC

IF

IC

F O

R T

H

IS

P R

O

JE

C T, U N

LE

SS

T H

E

PL

AN

S

AR

E

SI

G

N

ED

A N

D S

EA

LE

D B

Y

TH

E

SI

TE

D

ES

IG

N E

N G

IN

EE

R . T

H E

SI

TE

D

ES

IG

N

E N

G

IN

EE

R

S H

AL

L

R

EV

IE

W

T H

ES

E

D

ET

AI

LS

P R

IO

R

T O

C O

N

ST

R U

C

TI

O N

A N

D S

EA

LI

N G

T H

E D

O C

U M

EN

T.

IT

IS

T H

E

SI

TE

D

ES

IG

N E

N G

IN

EE

R 'S

R

ES

PO

N

SI

BI

LI

TY

T O

EN

SU

R E

TH

E

D

ET

AI

LS

P R

O

VI

D

ED

H

ER

EI

N

M

EE

TS

O

R E

XC

EE

D S

TH

E

AP

PL

IC

AB

LE

N

AT

IO

N

AL

, S

TA

TE

, O

R L

O C

AL

R

EQ

U

IR

EM

EN

TS

A N

D T

O E

N

SU

R E

TH

AT

T H

E D

ET

AI

LS

P

R O

VI

D

ED

H

ER

EI

N A

R E

AC

C

EP

TA

BL

E

FO

R

T H

IS

P

R O

JE

C

T.

R

EV

IE

W

ED

D R

AW

N

PR

O

JE

C

T N

O

D

AT

E:

SHEET

R

EV

T R

U

EM

AN

B

LV

D

H

IL

LI

AR

D , O

H

Ad va nc ed

D ra in ag e Sy st em s, In c.

St or m Te ch C ha m be r S ys te m

8-

2-

W W

W .S

TO

R

M

TE

C H

.C O

M

M C

-4

ST

AN

D

AR

D

D

ET

AI

LS

JL

M JL

M

/1

0/

Advanced Drainage Systems, Inc.

IMPORTANT - NOTES FOR THE BIDDING AND INSTALLATION OF MC-4500 CHAMBER SYSTEM

1. STORMTECH MC-4500 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A

PRE-CONSTRUCTION MEETING WITH THE INSTALLERS.

2. STORMTECH MC-4500 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500

CONSTRUCTION GUIDE".

3. CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR EXCAVATOR SITUATED OVER THE CHAMBERS.

STORMTECH RECOMMENDS 3 BACKFILL METHODS:

· STONESHOOTER LOCATED OFF THE CHAMBER BED.

· BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE.

· BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR.

4. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS.

5. JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE.

6. MAINTAIN MINIMUM - 9" (230 mm) SPACING BETWEEN THE CHAMBER ROWS.

7. INLET AND OUTLET MANIFOLDS MUST BE INSERTED A MINIMUM OF 12" (300 mm) INTO CHAMBER END CAPS.

8. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE MEETING THE AASHTO M43

DESIGNATION OF #3 OR #4.

9. STONE SHALL BE BROUGHT UP EVENLY AROUND CHAMBERS SO AS NOT TO DISTORT THE CHAMBER SHAPE. STONE DEPTHS SHOULD NEVER DIFFER BY MORE THAN 12" (300 mm) BETWEEN ADJACENT CHAMBER ROWS.

10. STONE MUST BE PLACED ON THE TOP CENTER OF THE CHAMBER TO ANCHOR THE CHAMBERS IN PLACE AND PRESERVE ROW

SPACING.

11. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIAL BEARING CAPACITIES TO THE

SITE DESIGN ENGINEER.

12. ADS RECOMMENDS THE USE OF "FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE

SUBSURFACE STORMWATER MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF.

NOTES FOR CONSTRUCTION EQUIPMENT

1. STORMTECH MC-4500 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500

CONSTRUCTION GUIDE".

2. THE USE OF EQUIPMENT OVER MC-4500 CHAMBERS IS LIMITED:

· NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS.

· NO RUBBER TIRED LOADER, DUMP TRUCK, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN

ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION GUIDE".

· WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION

GUIDE".

3. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING.

USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY USING THE "DUMP AND PUSH" METHOD ARE NOT COVERED

UNDER THE STORMTECH STANDARD WARRANTY.

CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR

CONSTRUCTION EQUIPMENT.

MC-4500 STORMTECH CHAMBER SPECIFICATIONS

1. CHAMBERS SHALL BE STORMTECH MC-4500.

2. CHAMBERS SHALL BE ARCH-SHAPED AND SHALL BE MANUFACTURED FROM VIRGIN, IMPACT-MODIFIED POLYPROPYLENE

COPOLYMERS.

3. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION 60x101.

4. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORTS THAT WOULD

IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION.

5. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG-DURATION DEAD LOADS AND 2) SHORT-DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH

CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES.

6. CHAMBERS SHALL BE DESIGNED, TESTED AND ALLOWABLE LOAD CONFIGURATIONS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". LOAD CONFIGURATIONS SHALL INCLUDE: 1) INSTANTANEOUS (<1 MIN) AASHTO DESIGN TRUCK LIVE LOAD ON MINIMUM COVER 2) MAXIMUM PERMANENT (75-YR) COVER LOAD AND 3) ALLOWABLE COVER WITH PARKED (1-WEEK) AASHTO

DESIGN TRUCK.

7. REQUIREMENTS FOR HANDLING AND INSTALLATION:

· TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.

· TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE

LESS THAN 3”.

· TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE

GREATER THAN OR EQUAL TO 450 LBS/FT/%. THE ASC IS DEFINED IN SECTION 6.2.8 OF ASTM F2418. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE

PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.

8. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. UPON REQUEST BY THE SITE DESIGN ENGINEER OR OWNER, THE CHAMBER MANUFACTURER SHALL SUBMIT A STRUCTURAL EVALUATION FOR APPROVAL BEFORE

DELIVERING CHAMBERS TO THE PROJECT SITE AS FOLLOWS:

· THE STRUCTURAL EVALUATION SHALL BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER.

· THE STRUCTURAL EVALUATION SHALL DEMONSTRATE THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95

FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY SECTIONS 3 AND 12.12 OF THE

AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS FOR THERMOPLASTIC PIPE.

· THE TEST DERIVED CREEP MODULUS AS SPECIFIED IN ASTM F2418 SHALL BE USED FOR PERMANENT DEAD LOAD DESIGN

EXCEPT THAT IT SHALL BE THE 75-YEAR MODULUS USED FOR DESIGN.

9. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY.

INSPECTION & MAINTENANCE

STEP 1) INSPECT ISOLATOR ROW PLUS FOR SEDIMENT

A. INSPECTION PORTS (IF PRESENT)

A.1. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN

A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED

A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4. LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.

B. ALL ISOLATOR PLUS ROWS

B.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS

B.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE

i)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE

B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.

STEP 2) CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS

A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED

B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN

C. VACUUM STRUCTURE SUMP AS REQUIRED

STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS.

STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.

NOTES

1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS

OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.

2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.

4" PVC INSPECTION PORT DETAIL (MC SERIES CHAMBER)

NOTE:

INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION VALLEY.

STORMTECH CHAMBER

4" (100 mm) INSERTA TEE

TO BE CENTERED ON CORRUGATION VALLEY

CONCRETE COLLAR

ASPHALT OVERLAY FOR

TRAFFIC APPLICATIONS

12" (300 mm) MIN WIDTH

8" (200 mm) MIN THICKNESS OF ASPHALT

OVERLAY AND CONCRETE COLLAR

8" NYLOPLAST UNIVERSAL DRAIN BODY

(PART# 2708AG4IPKIT) OR TRAFFIC RATED

BOX W/SOLID LOCKING COVER

CONCRETE COLLAR / ASPHALT OVERLAY

NOT REQUIRED FOR GREENSPACE OR

NON-TRAFFIC APPLICATIONS

4" (100 mm) SDR 35 PIPE

NYLOPLAST 8" LOCKING SOLID

COVER AND FRAME

UNDERDRAIN DETAIL

A

A

B B

SECTION A-A

SECTION B-B

NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER

4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS 6" (150 mm) TYP FOR SC-740, SC-800, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS

OUTLET MANIFOLD

STORMTECH

END CAP

STORMTECH

CHAMBERS

STORMTECH

CHAMBER

STORMTECH

END CAP

DUAL WALL

PERFORATED

HDPE

UNDERDRAIN

ADS GEOSYNTHETICS 601T

NON-WOVEN GEOTEXTILE

ADS GEOSYNTHETICS 601T

NON-WOVEN GEOTEXTILE

FOUNDATION STONE

BENEATH CHAMBERS

FOUNDATION STONE

BENEATH CHAMBERS

WELL COVER IN SIDEWALK

PLAN VIEW

WELL SECTION

PLAN VIEW

SECTION

TOP OF CHAMBER

TOP OF FACILITY

BOTTOM OF CHAMBER

BOTTOM OF FACILITY

531-24-108_P0.DWG 12/4/2024

12/02/2024

SCALE:

NORTH

DEMOLITION HVAC PLUMBING HYDRONICS PLAN1 1/4" = 1'-0" SCALE:

DEMOLITION WASTE VENT PLAN2 1/4" = 1'-0"

P1

SCALE:

SITE CONDITIONS3 NTS

531-24-108_P1.DWG

85P0HV.DWG

85P0WV.DWG

12/4/2024

SCALE:

HVAC PLUMBING HYDRONICS PLAN1 1/4" = 1'-0" SCALE:

WASTE VENT PLAN2 1/4" = 1'-0"

531-24-108_P2.DWG

85P0HV.DWG

85P0WV.DWG

12/4/2024

NOTE:

PROVIDE THREE SUPPORT RODS FOR STRUT LONGER THAN 24"

531-24-108_P3.DWG 12/4/2024

Sheets and Views
C0.0 COVER SHEET
C1.0 TESC AND DEMO PLANS
C2.0 DRAINAGE PLAN
C3.0 PAVING PLAN
C4.0 PAVING AND DRAINAGE DETAILS
SEEPAGE BED DETAIL
ASPHALT PATCH DETAIL
ASPHALT PAVEMENT
CONCRETE SIDEWALK
CURB AND GUTTER
SEDIMENT TRAP CATCH BASIN
TRENCH SECTION

File details come from the government source that posted it. Updated .