S02 Drawings 1.pdf

PDF 8 MB Posted

Attached to
Z2DA--693-22-104 | Construct Women's Health Radiology Suite
Solicitation number
36C24422R0041
Issued by

About this file

This solicitation is for design and construction services to renovate four rooms and install a new mammography imaging system at a Veterans Affairs medical center. Key details include renovating Rooms C2-34, C2-35, C2-35A and C2-33A to construct a new Women's Health Radiology Suite, acquiring a mammography imaging system through the National Acquisitions Center program for High Tech Medical Equipment, and addressing all associated design and construction requirements. The solicitation is issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAWBPKRYNIJ

Text Box

THESE TWENTY - THREE (23) CONSTRUCTION DOCUMENTS PROVIDED FOR REFERENCE.

VHAWBPKRYNIJ

Text Box

Project 693-22-104 Renovate Wound Care Clinic -Partial Set of Construction Documents.

NON RATED SMOKE PARTITION SUITE SEPARATION

1 HOUR FIRE RATED BARRIER / PARTITION

EXIT ACCESS CORRIDORS EXIT / EXIT PASSAGEWAY

NOTE:

RATED PARTITIONS AND SMOKE BARRIERS SHOWN ON THE EGRESS PLAN ARE A

COMBINATION OF NEW AND EXISTING CONSTRUCTION.

SEE DRAWINGS AE-121 AND AE-402 FOR REQUIREMENTS OF NEW CONSTRUCTION

AND VERIFICATION OF EXISTING.

EXIT DISCHARGE SMOKE COMPARTMENT EXIT

200'-0" MAX.

TOTAL TRAVEL DISTANCE TO AN EXIT

200'-0" MAX.

SMOKE COMPARTMENT TRAVEL DISTANCE (NFPA)

100'-0" MAX.

SUITE TRAVEL DISTANCE

ASSEMBLY UNCONCENTRATED

BUSINESS

MECHANICAL OCCUPANT LOAD

OUTPATIENT TREATMENT

STORAGE

EXISTING NON RATED SMOKE PARTITION

EXISTING 1 HOUR FIRE RATED BARRIER / PARTITION

EXISTING 2 HOUR FIRE RATED BARRIER / PARTITION

NON RATED SMOKE PARTITION

1 HOUR FIRE RATED SMOKE BARRIER

2 HOUR FIRE RATED BARRIER / PARTITION

2 HOUR FIRE RATED SMOKE BARRIER

MAXIMUM ALLOWABLE TRAVEL DISTANCE

SUITE TRAVEL DISTANCE

CORRIDOR ACCESS (MIN.)

CORRIDORS I-2 BED MOVEMENT

ALLOWABLE DEAD END CORRIDOR

WITH OCCUPANT LOAD GREATER THAN 30

CORRIDORS NON HOSPITAL

COMMON PATH OF TRAVEL

INTERIOR WALL AND CEILING FINISH REQUIREMENTS

INTERIOR FLOOR FINISH REQUIREMENTS

EXISTING BUILDING AREA

BUILDING OCCUPANCY CLASSIFICATION

TYPE OF CONSTRUCTION

TRAVEL DISTANCE

FIRE SUPPRESSION SYSTEM

CORRIDOR WIDTH

INTERIOR FINISHES

CORRIDOR FIRE-RESISTANT RATING

(MINIMUM) NUMBER OF EXITS REQUIRED

(MINIMUM) STAIR, DOOR AND CORRIDOR WIDTH

OCCUPANT

EXIT

OCCUPANT LOAD

EXIT CAPACITY

EXISTING BUILDING HEIGHT

PROJECT AREA

NFPA 101 2010

EXISTING HEALTHCARE AND AMBULATORY HEALTHCARE

TYPE II (2,2,2)

12 STORIES

NFPA 13 SPRINKLER SYSTEM

30 FEET

96 INCHES

60 INCHES

100 FEET

200 FEET

CLASS A OR B

SMOKE PARTITION

682,000 SF

16,757 SF

CLASS A OR B

44 INCHES

100 FEET

(EXISTING) STAIR: 36"

(EXISTING) DOOR: 36"

(EXISTING) CORRIDOR: 44"

EX. ELEC

EX.

WELLNESS

OFFICE

EX. CARDIAC

REHAB

OFFICE

EX. OT

CLINIC

EX. CARDIAC

REHAB

EX.

RECREATION

THERAPY

EX. MECH

ELEC

MECH

IT ROOM

PHONES

PROSTHETICS

STORAGE

EX. CT

WAITING

EX. FILES

STAIR #3

CLEAN

SUPPLY

W.C. UV /

WHIRLPOOL

W.C. OFFICE

W.C.

TREATMENT

W.C.

BARIATRIC

TREATMENT

ULTRASOUND

WAITING

WOMEN'S

TOILET

BARIATRIC

ULTRASOUND

EXAM 2

WAITING

RECEPTIONIST

TOILET

ULTRASOUND

EXAM 2

BARIATRIC

ULTRASOUND

EXAM 1

BARIATRIC

TOILET

ULTRASOUND

TECHS /

FILES

ULTRASOUND

EXAM 1

SOILED

UTILITY

N.M.

SECRETARY

MULTIPURPOSE

ROOMN.M.

SUPERVISOR

OFFICE

STAFF

TRAINING REHAB

OFFICE

SUPERVISOR

CHIEF

OFFICE

REHAB &

PROSTH.

OFFICE

PET CT

WAITING

REHAB VIST.

ASSIST.

OFFICE

MEN'S

TOILET

WOMEN'S

TOILET

OT CLINIC

OFFICE

CLEAN

HOLDING

ORTHOTICS

STORAGE/REPAIRS

ORTHOTICS

TREATMENT

EMG

PROSTHETICS

SUPERVISOR

OFFICE

ORTHOTICS

OFFICE

SOILED

HOLDING /

UTILITY

ELEC MECH

STAIR # 2

EX. TOILET

HOUSEKEEPING

MEN'S

TOILET

WOMEN'S

TOILET

STORAGE

PROSTHETICS

PURCHASING

OFFICE

97'-0" TRAVEL DISTANCE 100'-0" TRAVEL DISTANCE 63'-2" TRAVEL DISTANCELESS THAN

30' DEAD

END CORR.

EXISTING NON-CONFORMING DEAD END CORRIDOR

'-0

" T R

A

VE

L D

IS

TA

N C

E

'-1

0" T

R A

VE

L

D

IS

TA

N

C E

STAIR NO.

STAIR CAPACITY

DOOR CAPACITY

STAIR WIDTH

DOOR CLEAR WIDTH

45"

42"

STAIR NO.

STAIR CAPACITY

DOOR CAPACITY

STAIR WIDTH

DOOR CLEAR WIDTH

45"

42"

STAIR NO.

STAIR CAPACITY

DOOR CAPACITY

STAIR WIDTH

DOOR CLEAR WIDTH

39"

36"

STAIR NO.

STAIR CAPACITY

DOOR CAPACITY

STAIR WIDTH

DOOR CLEAR WIDTH

48"

44"

STAIR NO.

STAIR CAPACITY

DOOR CAPACITY

STAIR WIDTH

DOOR CLEAR WIDTH

53"

42"

F.E.C

F.E.C

F.E.C

F.E.C

F.E.C

EX. ELEC

EX.

WELLNESS

OFFICE

EX. CARDIAC

REHAB

OFFICE

EX. OT

CLINIC

EX. CARDIAC

REHAB

EX.

RECREATION

THERAPY

EX. MECH

ELEC

MECH

IT ROOM

PHONES

PROSTHETICS

STORAGE

EX. CT

WAITING

EX. FILES

STAIR #3

CLEAN

SUPPLY

W.C. UV /

WHIRLPOOL

W.C. OFFICE

W.C.

TREATMENT

W.C.

BARIATRIC

TREATMENT

ULTRASOUND

WAITING

WOMEN'S

TOILET

BARIATRIC

ULTRASOUND

EXAM 2

WAITING

RECEPTIONIST

TOILET

ULTRASOUND

EXAM 2

BARIATRIC

ULTRASOUND

EXAM 1

BARIATRIC

TOILET

ULTRASOUND

TECHS /

FILES

ULTRASOUND

EXAM 1

SOILED

UTILITY

N.M.

SECRETARY

MULTIPURPOSE

ROOMN.M.

SUPERVISOR

OFFICE

STAFF

TRAINING

REHAB

OFFICE

SUPERVISOR

CHIEF

OFFICE

REHAB &

PROSTH.

OFFICE

PET CT

WAITING

REHAB VIST.

ASSIST.

OFFICE

MEN'S

TOILET

WOMEN'S

TOILET

OT CLINIC

OFFICE

CLEAN

HOLDING

ORTHOTICS

STORAGE/REPAIRS

ORTHOTICS

TREATMENT

EMG

PROSTHETICS

SUPERVISOR

OFFICE

ORTHOTICS

OFFICE

SOILED

HOLDING /

UTILITY

ELEC MECH

STAIR # 2

EX. TOILET

HOUSEKEEPING

MEN'S

TOILET

WOMEN'S

TOILET

STORAGE

PROSTHETICS

PURCHASING

OFFICE

EX. TOILET

EX. TOILET

EX.

VESTIBULE

BARIATRIC

TOILET

MECHANICAL

ROOM

C5-75

GENERAL NOTES:

1) ALL RATED INTERIOR PARTITION SHOULD BE CONSTRUCTED IN ACCORDANCE WITH

THE RATED PARTITION SCHEDULE UNLESS NOTED OTHERWISE ON THE FLOOR PLANS

2) CONTRACTOR TO PATCH AND REPAIR ALL NEW AND EXISTING FIREPROOFING AFTER

INSTALLATION OF NEW WORK AS REQUIRED TO MAINTAIN REQUIRED FIRE RATING.

CONTRACTOR TO USE MATERIALS COMPATIBLE WITH EXISTING FIREPROOFING FOR

PATCH WORK.

NON-LOADBEARING WALLS AND PARTITIONS HOURS UL DESIGN #

SMOKE BARRIERS (8.5)

FIRE WALLS (8.3)

FIRE PARTITIONS (8.3)

EXIT ENCLOSURES (7.2.2.5)

HORIZONTAL EXITS (7.2.4)

INCIDENTAL USE AREAS (7.2.4)

EXITS PASSAGEWAY (7.2.6)

SHAFT ENCLOSURES (8.6) # U438

# U411

# U465

N/A

N/A

N/A

# U465

# U419

N PLAN NORTH

AREA C

KEY PLAN

AREA A

AREA B

MECHANICAL

ROOM

C3-51A

1. EXISTING EXITS TO BE MAINTAINED DURING DEMOLITION / CONSTRUCTION.

PROVIDE TEMPORARY PROTECTION AS REQUIRED TO MAINTAIN EGRESS AND SAFE

PASSAGE FROM THE BUILDING.

2. PROVIDE HEPA EXHAUST FANS TO KEEP SPACE WITHIN THE PROJECT AREA

UNDER NEGATIVE PRESSURE AS LOCATIONS AND CONDITIONS DICTATE.

3. PROVIDE TEMPORARY PROTECTION WHILE WORKING IN THE SPACES, BELOW

OR ABOVE THE AREA OF DEMOLITION / CONSTRUCTION.

4. PROVIDE BARRIERS, TEMPORARY PARTITIONS TO PROTECT OCCUPANTS FROM

PHYSICAL HAZARD AND NOISE DURING DEMOLITION / CONSTRUCTION AND AS

REQUIRED FOR INFECTION CONTROL.

5. THE LOCATION OF CONSTRUCTION DOORS IN CONSTRUCTION BARRIERS TO BE

DETERMINED BY THE CONTRACTOR. DOORS AND FRAMES IN CONSTRUCTION

BARRIERS TO BE HOLLOW METAL. DOORS TO BE SELF CLOSING AND LOCKABLE.

6. COORDINATE DEMOLITION WITH PHASING PLANS INTEGRATING DEMOLITION

WITH EXISTING CONSTRUCTION TO MINIMIZE DISRUPTION OF BUILDING OPERATIONS.

SMOKE COMPARTMENT A - 11,548 SQ FT

SMOKE COMPARTMENT B - 26,035 SQ FT

SMOKE COMPARTMENT C - 8,952 SQ FT

SMOKE COMPARTMENT D - 7,118 SQ FT

King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406

2520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 120 www.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.com f: 610.755.6564f: 610.755.6564f: 610.755.6564f: 610.755.6564 t: 610.755.6464t: 610.755.6464t: 610.755.6464t: 610.755.6464

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

VA Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Project Number Scale

Structural Engineer

One East Uwchlan Avenue Suite 403 Exton, PA 19341 Tel (484) 475-2180 Fax (484) 475-2181

MacIntosh Engineering

MEP Engineer

102 Highland Avenue Clarks Summit, PA 18411 Tel (570) 586-4334 Fax (570) 587-8164

Highland Associates

Haz-Mat Consultant

1047 North Park Road P.O. Box 6307 Reading, PA 19610-0307 Tel (610) 621-2000 Fax (610) 621-2001

SSM Group, Inc.

of 59

As indicated

1111 East End Blvd, Wilkes-Barre, PA 18711

RENOVATE WOUND CARE CLINIC

JP EN

LIFE SAFETY PLAN

09/01/11

GC-121

100% CONSTRUCTION DOCUMENTS - ISSUED FOR BID

FULLY SPRINKLERED

3436 693-09-129

1/16" = 1'-0" F1

2ND FLOOR EGRESS AND LIFE SAFETY PLAN

1/16" = 1'-0" F4

2ND FLOOR OCCUPANCY PLAN

1/16" = 1'-0" B7

3RD FLOOR - EXIST. DUMBWAITER AREA

1/16" = 1'-0" B8

4TH FLOOR - EXIST. DUMBWAITER AREA

1/16" = 1'-0"

B9

5TH FLOOR - EXIST. MECHANICAL ROOM

1/16" = 1'-0" C2

PARTIAL 3RD FLOOR LIFE SAFETY PLAN

Revisions Date

VHAWBPKRYNIJ

Rectangle

VHAWBPKRYNIJ

Rectangle

VHAWBPKRYNIJ

Text Box Primary area of work - outlined in red throughout floor plans in this reference document set.

VHAWBPKRYNIJ

Line

Line

PO

MKJ L

VU

TSRQ

Q.8 S.2 S.9

EX. ELEC

C2-39C

EX.

WELLNESS

OFFICE

C2-39A

EX.

CARDIAC

REHAB

OFFICE

C2-40A

EX. OT

CLINIC

C2-43

EX.

CARDIAC

REHAB

C2-40

EX.

RECREATION

THERAPY

C2-39

EX. MECH

C2-39B

ELEC

C2-46A

MECH

C2-106A

IT ROOM

C2-106B

PHONES

C2-106C

PROSTHETICS

STORAGE

N2-97

EX. CT

WAITING

N2-095

EX. FILES

STAIR #3

S-3

CLEAN

SUPPLY

N2-48A

W.C. UV /

WHIRLPOOL

N2-98

W.C. OFFICE

N2-99

W.C.

TREATMENT

N2-100

W.C.

BARIATRIC

TREATMENT

N2-102

ULTRASOUND

WAITING

C2-29

WOMEN'S

TOILET

C2-28

BARIATRIC

ULTRASOUND

EXAM 2

C2-33B

WAITING

C2-105

RECEPTIONIST

C2-104

TOILET

C2-31C

ULTRASOUND

EXAM 2

C2-31B

BARIATRIC

ULTRASOUND

EXAM 1

C2-33E

BARIATRIC

TOILET

C2-33C

ULTRASOUND

TECHS /

FILES

C2-30

ULTRASOUND

EXAM 1

C2-31A

SOILED

UTILITY

C2-33D

N.M.

SECRETARY

C2-34

MULTIPURPOSE

ROOM

C2-35A

N.M.

SUPERVISOR

OFFICE

C2-35

STAFF

TRAINING

C2-24A

REHAB

OFFICE

SUPERVISOR

C2-24B

CHIEF

OFFICE

C2-24C

REHAB &

PROSTH.

OFFICE

C2-24D

PET CT

WAITING

C2-25

REHAB VIST.

ASSIST.

OFFICE

C2-23

MEN'S

TOILET

C2-41B

WOMEN'S

TOILET

C2-41A

OT CLINIC

OFFICE

C2-42

CLEAN

HOLDING

C2-31D

ORTHOTICS

STORAGE/REPAIRS

N2-50

ORTHOTICS

TREATMENT

N2-49

EMG

N2-48

PROSTHETICS

SUPERVISOR

OFFICE

N2-53A

ORTHOTICS

OFFICE

N2-50A

SOILED

HOLDING /

UTILITY

C2-47

ELEC

C2-27

MECH

C2-27A

STAIR # 2

S-2

EX. TOILET

C2-106

HOUSEKEEPING

N2-55

MEN'S

TOILET

N2-54B

WOMEN'S

TOILET

N2-54A

STORAGE

N2-53B

PROSTHETICS

PURCHASING

OFFICE

N2-53

ELEC

C2-46

N

EX. TOILET

C2-38

EX. TOILET

C2-37

EX.

VESTIBULE

C2-36

CORRIDOR

C2-32CORRIDOR

C2-32

BARIATRIC

TOILET

C2-33A

EX. OFFICE

N2-96

CLOS.

C2-42A

N

AREA C

KEY PLAN

AREA A

AREA B

1. PLANS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. ANY

WORK EXHIBITED IN EITHER OF THEM WHETHER IN THE OTHER OR NOT, IS TO BE

EXECUTED AS PART OF THE WORK. THE SPECIFICATIONS, DRAWINGS AND

ADDITIONAL OWNER PROVIDED INFORMATION INCLUDE THE ENTIRE WORK.

WHERE ITEMS OF MATERIAL, EQUIPMENT AND LABOR ARE REFERRED TO IN THE

SINGULAR, SUCH ITEM OR ITEMS SHALL BE PROVIDED IN THE NUMBER NECESSARY

FOR THE PROPER COMPLETION OF THE WORK. THE DRAWINGS ARE A GRAPHIC

REPRESENTATION OF THE SCOPE, LOCATION AND ARRANGEMENT OF MATERIALS

AND EQUIPMENT SHOWING THE EXECUTION OF THE WORK. THE INTENT OF THE

SPECIFICATIONS IS TO OUTLINE OR INDICATE THE ITEMS OF WORK, OR OTHER,

WHICH CANNOT READILY BE SHOWN ON THE DRAWINGS, AND FURTHER TO

INDICATE THE TYPES AND QUALITIES OF MATERIALS AND WORKMANSHIP. SHOULD

THE SPECIFICATIONS AND DRAWINGS DISAGREE IN THEMSELVES, OR WITH EACH

OTHER, WRITTEN CLARIFICATIONS SHOULD BE REQUESTED OF THE ARCHITECT BY

THE CONTRACTOR.

2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE HIS

WORK WITH THAT OF ALL OTHER TRADES, INCLUDING, BUT NOT LIMITED TO,

ELECTRICAL, HVAC PIPING, SPRINKLER, PLUMBING, STRUCTURAL AND GENERAL

ARCHITECTURE. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF

THE CM/GC AND THE ARCHITECT, AND SHALL BE RESOLVED PRIOR TO THE

INSTALLATION OF THE WORK INVOLVED.

3. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE

APPLICABLE CODE AND ALL APPLICABLE COUNTY, CITY, STATE, FEDERAL LAWS

AND REGULATIONS. NO WORK SHALL BE INSTALLED IN VIOLATION OF ANY CODES;

ANY WORK SHOWN ON THE DRAWINGS WHICH IS IN VIOLATION OF SUCH CODES

SHALL BE BROUGHT TO THE ATTENTION OF THE CM/GC AND THE ARCHITECT AND

SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED.

4. ANY UTILITY SHUT-OFFS AS REQUIRED BY CONTRACTORS FOR THE

COMPLETION OF THEIR WORK SUCH AS ELECTRICAL, GAS, WATER, SEWER, STEAM,

SPRINKLER, ETC., MUST BE SCHEDULED THROUGH THE PROJECT ENGINEER AND

GC PRIOR TO COMMENCEMENT OF THE WORK. 72 HOURS NOTICE MUST BE GIVEN.

5. IT IS NOT THE INTENT OF THESE DOCUMENTS TO SHOW EVERY MINOR DETAIL

OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL

ALL ITEMS REQUIRED TO COMPLETE CONSTRUCTION. ALL THE WORK SHALL BE

INSTALLED WITH QUALITY WORKMANSHIP IN ACCORDANCE WITH INDUSTRY

STANDARDS AND BE IN PROPER WORKING ORDER.

6. THE CONTRACTOR SHALL COORDINATE WITH THE PROJECT ENGINEER FOR

REGULATIONS INCLUDING, BUT NOT LIMITED TO, ELEVATOR USE, RUBBISH

REMOVAL, PROTECTION OF BASE BUILDING CONSTRUCTION, AND ANY WORK

WHICH WILL AFFECT OTHER PARTS OF THE BUILDING.

7. THE CONTRACTOR SHALL PROVIDE CHASES FOR MECHANICAL, PLUMBING,

AND ELECTRICAL AS NECESSARY TO CONCEAL M.E.P. WORK. PIPING LOCATED

INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES WITH THE

EXCEPTION OF PIPING IN STAIRWAYS AND EQUIPMENT ROOMS. THE CONTRACTOR

SHALL COORDINATE WITH THE OTHER TRADES TO PROVIDE FURRING FOR PIPING

INSTALLED IN FINISHED AREAS. THE CONTRACTOR SHALL GAIN APPROVAL FROM

THE ARCHITECT PRIOR TO LOCATING AND/OR PROVIDING “FURRED SPACES” NOT

INDICATED ON THE FLOOR PLANS.

8. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE SPECIFIED

ARE INSTALLED IN WALLS WHERE ACCESS, SERVICE OR ADJUSTMENT TO

MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS

PANELS SHALL HAVE THE SAME FIRE RATING OF THE WALL, SOFFIT OR CEILING IN

WHICH THEY OCCUR. ALSO, PROVIDE 12"X12" ACCESS PANELS AT DRYWALL

CEILINGS TO PROVIDE ACCESS TO RATED PARTITIONS (30'-0” O.C. MAX OR 1 PER

ROOM MINIMUM.).

9. EACH CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS FOR

THE PROPER STORAGE OF BUILDING MATERIALS ON THE SITE TO AVOID

OVERLOADING THE FLOOR OR IMPEDING WITH COMPLETION OF THE WORK.

MATERIALS ARE TO BE PROPERLY DISPERSED OVER BEAMS BETWEEN COLUMNS.

10. WHERE NEW WORK CONNECTS WITH EXISTING, THE CONTRACTOR SHALL DO

ALL NECESSARY CUTTING, FITTING, AND PATCHING. CONTRACTOR SHALL FURNISH

ALL NECESSARY LABOR AND MATERIALS FOR THIS WORK WHETHER OR NOT

SHOWN AND/OR SPECIFIED.

11. ALL MATERIALS, METHODS OF INSTALLATION SHALL CONFORM TO THE

MANUFACTURER'S SPECIFICATIONS AND INSTALLATION INSTRUCTIONS.

1. DO NOT SCALE DRAWINGS. DIMENSIONS IN LARGE SCALE PLANS, ELEVATIONS, AND

DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. IF DIMENSIONS ARE IN QUESTION,

THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE

ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.

2. DIMENSIONS SHOWN ON THE FLOOR PLANS FOR NEW CONSTRUCTION ARE TO

CENTERLINE OF COLUMNS TO FINISH FACE OF INTERIOR PARTITION, CONCRETE OR

MASONRY INTERIOR WALLS AND TO EXTERIOR FACE OF STUDS, CONCRETE OR MASONRY

EXTERIOR WALLS.

3. WHERE A ONE HOUR OR NON-RATED PARTITION IS SHOWN AS A CONTINUATION OF

A TWO HOUR PARTITION OR COLUMN ENCASEMENT, THE FACE OF THE GYPSUM BOARD

SHALL BE ALIGNED. STUDS SHALL BE OFFSET AND AN ADDITIONAL LAYER OF GYPSUM

BOARD SHALL BE PROVIDED TO PROVIDE FACE ALIGNMENT OF GYPSUM BOARD.

4. ALL WALL MOUNTED LAVATORIES SHALL BE MOUNTED TO ALLOW FOR 1'-3” MINIMUM

BETWEEN THE CENTERLINE OF THE LAVATORY AND FACE OF ADJACENT WALL, UNLESS

OTHERWISE NOTED. THERE IS AN ADDITIONAL REQUIREMENT TO PROVIDE A MINIMUM OF

4” BETWEEN SIDE OF LAVATORY AND FACE OF ADJACENT WALL, FIXED EQUIPMENT,

CASEWORK, ETC.

5. ALL WATER CLOSETS SHALL BE MOUNTED SO THAT THERE IS 1'-6” BETWEEN FACE

OF THE CLOSEST ADJACENT SIDE WALL OR TOILET PARTITION AND THE CENTERLINE OF

THE WATER CLOSET. THE FLUSH VALVE FOR ALL WATER CLOSETS SHALL BE MOUNTED

ON THE “OPEN-MOST” SIDE OF THE WATER CLOSET AT 44” MAXIMUM A.F.F. TO THE TOP.

6. IN GROUP I2/HEALTHCARE, CORRIDOR WIDTH TO BE 8'-0" CLEAR IN AREAS WHERE

REQUIRED FOR BED MOVEMENT.

7. DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO FABRICATION AND INSTALLATION

OF CASEWORK. REFER TO CASEWORK NOTES FOR ADDITIONAL INFORMATION.

8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LATEXING AND TAPERING

EXISTING CONCRETE FLOOR SLAB WHERE MATERIAL CHANGES OCCUR AND SHALL

COORDINATE SAME WITH CARPET INSTALLER.

9. CONTRACTOR SHALL BUILD OUT PARTITIONS TO ACCOMMODATE DEPTH REQUIRED

BY FIRE EXTINGUISHER CABINETS AND RECESSED POWER PANELS. COORDINATE WITH

ENGINEERING DRAWINGS. FINAL LOCATIONS OF ALL CABINETS AND PANELS TO BE

APPROVED BY ARCHITECT.

10. PROVIDE METAL STUD FRAMING AROUND ALL PENETRATIONS THRU METAL STUD /

GYPSUM PARTITIONS. REFER TO DETAILS TO FOLLOW FOR PATCHING PENETRATIONS IN

RATED WALLS.

11. THE FLOOR SLAB SHALL BE SLOPED (2%) TO ALL DRAINS.

12. ALL MASONRY WALLS WITHIN SCOPE OF WORK TO RECEIVE WALL LINER SYSTEM,

PARTITION TYPE WL U.N.O. SEE DIAGRAM B5/AE-122.

13. CONTRACTOR TO COORDINATE LOCATION OF CONSTRUCTION JOINTS WITH FINISH

FLOOR MATERIALS SO THAT NO CONSTRUCTION JOINT IS LOCATED BENEATH CERAMIC,

PORCELAIN OR QUARRY TILES.

14. PROVIDE SILICONE SEALANT AT JUNCTION OF WALL SURFACE WITH ALL PLUMBING

FIXTURES AND COUNTERTOPS.

TYPE 2A

TYPE 2

SAME AS TYPE 2 EXCEPT CARRY GYPSUM

WALLBOARD TO FLOOR/ ROOF DECK ABOVE

TYPE 2B SAME AS TYPE 2 EXCEPT 6" METAL

STUDS @ 16" O.C.

M

IN2"

UNFINISHED FLOOR SLAB

FASTEN RUNNER TO FLOOR/ROOF

DECK ABOVE AS REQUIRED BY

SPECIFICATIONS

CARRY WALLBOARD TO 2"

ABOVE FINISHED CEILING

SOUND ATTENUATION

FIRE BLANKET

GYPSUM WALLBOARD AT 2A ONLY

4 1/4"

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C. MAX.

3 5/8" METAL TRACK

TYPE 5

SOUND ATTENUATION

FIRE BLANKET

4 7/8"

UNFINISHED FLOOR

SLAB

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF

STRUCTURAL SYSTEM

ABOVE, AND SEAL TIGHT

(SEE NOTE #3 FOR WHERE SOUND

ATTENUATION BLANKET IS

REQUIRED)

STC 49

SEALANT

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C. MAX.

3 5/8" METAL TRACK

TYPE 12

1 HOUR FIRE

RATED WALL

UL DES U420

STC 52

TYPE 12A 1 HOUR RATED

SMOKE BARRIER UL DES U420

STC 52

FIRE STOPPING SEALANT

FINISHED CEILING

SOUND ATTENUATION FIRE

BLANKET

1 5/8" METAL RUNNER

UNFINISHED FLOOR SLAB

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE AND SEAL

TIGHT

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

1 5/8" METAL STUDS @ 16"

O.C.

SEE PLAN

FIRE STOPPING SEALANT

3-5/8" METAL STUD KICKER AT 4'-0" OC

MAX

4'

M

A X

1 HOUR FIRE

RATED WALLTYPE 10

STC 49

UL DES U465/U419

TYPE 10A

STC 49

UL DES U465/U419

4 7/8"

1 HOUR RATED

SMOKE BARRIER

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE, AND SEAL TIGHT

UNFINISHED FLOOR SLAB

SOUND ATTENUATION

FIRE BLANKET

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

FIRE STOPPING SEALANT

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C. MAX.

3 5/8" METAL TRACK

FIRE STOPPING SEALANT

TYPE 8

SAME AS TYPE 8 EXCEPT 6" STEEL

METAL STUDS AT 16" O.C.TYPE 8A

SMOKE PARTITION

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE

UNFINISHED FLOOR SLAB

SOUND ATTENUATION

FIRE BLANKET

M

IN2"

4 7/8"

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

SEALANT

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C. MAX.

3 5/8" METAL TRACK

FIRE SAFING INSULATION

TYPE 7

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE

PLUMBING CHASE

SEE PLAN

VARIES

UNFINISHED FLOOR SLAB

SOUND ATTENUATION

FIRE BLANKET

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

SEALANT

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C. MAX.3 5/8" METAL STUDS @ 16" O.C. MAX.

3 5/8" METAL TRACK3 5/8" METAL TRACK

TYPE 7A 1 HOUR RATED PLUMBING CHASE

STC 49

UL DES U465/U419

TYPE WL

UNFINISHED FLOOR

SLAB

FINISHED CEILING

1/4" TYPE X GYPSUM WALLBOARD

EXISTING PARTITION WITH VENEER PLASTER SYSTEM

A

EXISTING PARTITION

EXISTING BULLNOSE (VIF)

VENEER PLASTER SYSTEM

1. ALL FIRE RATED AND SMOKE BARRIER PARTITIONS MUST BE INSTALLED PER

THEIR UL DESIGN NUMBERS.

2. INSTALL FIRE SEALANT AROUND THE ENTIRE PERIMETER TO PREVENT THE

PASSAGE OF SMOKE IN ALL RATED AND SMOKE PARTITIONS.

3. INSTALL SOUND ATTENUATION BLANKET IN ALL PARTITIONS THAT FORM ANY

PART OF THE ENCLOSURE OF THE FOLLOWING ROOMS: PATIENT ROOMS, TOILET

ROOMS, EXAM ROOMS, TREATMENT ROOMS, OFFICES AND MECHANICAL ROOMS.

THESE PARTITIONS SHALL HAVE 3-1/2” FIBERGLASS BATT SOUND ATTENUATION

BLANKETS AND MEET MINIMUM SOUND TRANSMISSION RATING OF STC 45. USE

ACOUSTICAL SEALANT AROUND THE ENTIRE PERIMETER ON NON-RATED PARTITIONS.

4. REPLACE 5/8" GYPSUM WALLBOARD WITH 5/8" DENS-SHIELD IN ALL AREAS TO

RECEIVE CERAMIC TILE. SKIM COAT ENTIRE SURFACE NOT COVER BY TILE.

5. REPLACE 5/8" GYPSUM WALLBOARD WITH 5/8" MOISTURE AND MOLD-RESISTANT

GYPSUM WALL BOARD ON ALL PLUMBING WALL OTHER THAN THOSE COVERED IN

NOTE # 4 ABOVE.

6. FOR HEIGHTS UP TO AND INCLUDING 14'-0" TYPICAL INTERIOR METAL STUDS ARE

20 GA. AT 16" O.C.; FOR HEIGHTS ABOVE 14'-0", USE 18 GA AT 16" O.C.; USE DOUBLE 20

GA. STUDS AT DOORS AND BORROWED LIGHT FRAMES; USE DOUBLE 18 GA. STUDS

AT ICU SLIDING DOORS AND LEAD LINED DOORS AND BORROWED LIGHT FRAMES.

7. NOTIFY ARCHITECT OF WORK TO BE PERFORMED ON EXISTING PARTITIONS AND

PROVIDE PRICING ACCORDING TO UNIT PRICES OUTLINED IN SPECIFICATION

SECTION 012200.

8. INSTALL SUPPLEMENTARY FRAMING, BLOCKING, AND BRACING IN PARTITIONS TO

SUPPORT FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM, GRAB BARS, TOILET

ACCESSORIES, DOOR HARDWARE, FURNISHINGS, OR SIMILAR CONSTRUCTION.

COMPLY WITH DETAILS INDICATED AND WITH RECOMMENDATIONS OF "GYPSUM

CONSTRUCTION HANDBOOK".

9. WHEN INFILLING OR ABUTTING EXISTING PARTITIONS CONTRACTOR TO ADD AN

ADDITIONAL LAYER OF GYPSUM WALLBOARD TO PARTITION TYPE AND/OR SKIM COAT

WALL AS REQUIRED TO PROVIDE A FLUSH SURFACE. THICKNESS OF GYPSUM

WALLBOARD AND / OR STUD SIZE TO BE DETERMINED IN FIELD TO PROVIDE A FLUSH

SURFACE.

10. EXTEND ALL WALLS TO UNDERSIDE OF STRUCTURE ABOVE. PROVIDE SLIP

TRACK AT TOP OR ANOTHER APPROVED METHOD TO ALLOW FOR A 1" DEFLECTION

OF THE STRUCTURE.

11. REFER TO AE-402 FOR PENETRATION DETAILS AND HEAD PARTITION DETAILS.

TYPE 6

STC 49

UNFINISHED

FLOOR SLAB

SOUND ATTENUATION

FIRE BLANKET

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE AND SEAL TIGHT

(SEE NOTE #3 FOR WHERE SOUND

ATTENUATION BLANKET IS

REQUIRED)

7 1/4"

SEALANT

FINISHED CEILING

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

5/8" MOLD/MOISTURE RESISTANT TYPE

X GYPSUM WALLBOARD

6" METAL STUDS @ 16" O.C. MAX.

6" METAL TRACK

TYPE 14 2 HOUR FIRE

RATED WALL UL DES U411/U419

STC 56

TYPE 14A 2 HOUR RATED

SMOKE BARRIER UL DES U411/U419

STC 56

FIRE STOPPING

SEALANT

FINISHED CEILING

SOUND ATTENUATION

FIRE BLANKET

3 5/8" METAL STUDS

@ 16" O.C.

DOUBLE LAYER OF 5/8"

TYPE 'X' GYPSUM

3 5/8" METAL RUNNER

UNFINISHED FLOOR SLAB

FASTEN RUNNER TO

FLOOR/ROOF DECK ABOVE AS

REQUIRED BY SPECIFICATIONS

CARRY WALLBOARD TO

UNDERSIDE OF STRUCTURAL

SYSTEM ABOVE AND SEAL

TIGHT

(SEE NOTE #3 FOR WHERE

SOUND ATTENUATION

BLANKET IS REQUIRED)

6 1/8"

FIRE STOPPING SEALANT

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

VA Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS:

Office of Facilities

Management

Project Number Scale

Structural Engineer

One East Uwchlan Avenue Suite 403 Exton, PA 19341 Tel (484) 475-2180 Fax (484) 475-2181

MacIntosh Engineering

MEP Engineer

102 Highland Avenue Clarks Summit, PA 18411 Tel (570) 586-4334 Fax (570) 587-8164

Highland Associates

Haz-Mat Consultant

1047 North Park Road P.O. Box 6307 Reading, PA 19610-0307 Tel (610) 621-2000 Fax (610) 621-2001

SSM Group, Inc.

of 59

As indicated

1111 East End Blvd, Wilkes-Barre, PA 18711

RENOVATE WOUND CARE CLINIC

JP EN

OVERALL ARCHITECTURAL FLOOR PLAN AND

PARTITION TYPES

09/01/11

AE-121

3436 693-09-129

1/16" = 1'-0"

F1 OVERALL ARCHITECTURAL FLOOR PLAN

Revisions Date

Rectangle

EXISTING LOUVER BLANKED OFF AND PAINTED BY MECHANICAL CONTRACTOR.

CONTRACTOR TO PROVIDE 2 HR RATED EXPANSION JOINT. SEE

SPECIFICATIONS SECTION 079500 FOR TYPE.

FURNISH AND INSTALL FIRE SAFING AND FIRE SEALANT BETWEEN WALLS TO

ENSURE A CONTINUOUS RATING.

REINSTALL EXISTING 1" EXPANSION JOINT AND 10" COVERPLATE.

SOLID PHENOLIC PANEL LOCKER 24" W X 12" D X 72" H.

RETURN AIR DUCT FROM 2ND FLOOR.

RELOCATE EXISTING ELEVATOR CALL BUTTONS AND HALL LANTERNS TO NEW

FACE OF WALL. PROVIDE BACKBOX EXTENSIONS REQUIRED TO MAINTAIN

EXISTING 2 HOUR UL ASSEMBLY FOR ELEVATOR SHAFT. COORDINATE WORK

WITH ELEVATOR MANUFACTURER AND NOTIFY V.A. 2 WEEKS PRIOR TO START

OF WORK.

SUPPLY AIR DUCT DOWN TO 2ND FLOOR.

TOILET PARTITION SYSTEM.

PROVIDE SLOPED TILE FLOOR SYSTEM TO DRAIN FLOOR.

PROVIDE RUBBER FLOORING TO DRAIN FLOOR.

EXISTING PIPES TO REMAIN.

AREAS TO RECEIVE PARTITION TYPE WL REFERS TO EXISTING CMU WALLS TO

RECEIVE PLASTER FINISHES IN ROOMS TO 2" ABOVE CEILING. TYPICAL FINISHES

IN CORRIDORS C2-45, C2-22, C2-32A, N2-42A, AND N2-90 TO RECEIVE PLASTER

PER DETAIL D2/AE301.

(4) AREAS OF 4'-0" X 6'-0" FOR ACCESS PANELS AT EACH WALL. DEMOLITION BY

OWNER. FIELD LOCATED BY CONTRACTOR.

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

A13

A14

N PLAN NORTH

AREA C

KEY PLAN

AREA A

AREA B

MKJ L

EX. FILES

LIMIT OF WORK

AREA B

AREA A

AREA B

AREA A

N

AE-202

A5

CORRIDOR

N2-90

A6

WL

MKJ L

ELEC

C2-46A

MECH

C2-106A

IT ROOM

C2-106B

PHONES

C2-106C

PROSTHETICS

STORAGE

N2-97

EX. CT

WAITING

STAIR #3

S-3

CLEAN

SUPPLY

N2-48A

W.C. UV /

WHIRLPOOL

N2-98

W.C. OFFICE

N2-99

W.C.

TREATMENT

N2-100

W.C.

BARIATRIC

TREATMENT

N2-102

WAITING

C2-105

RECEPTIONIST

C2-104

ORTHOTICS

STORAGE/REPAIRS

N2-50

ORTHOTICS

TREATMENT

N2-49

EMG

N2-48

PROSTHETICS

SUPERVISOR

OFFICE

N2-53A

ORTHOTICS

OFFICE

N2-50A

SOILED

HOLDING /

UTILITY

C2-47

MEN'S TOILET

N2-54B

WOMEN'S

TOILET

N2-54A

STORAGE

N2-53B

PROSTHETICS

PURCHASING

OFFICE

N2-53

CHANGE

N2-98A

N2-102A

ELEC

C2-46

AREA B

AREA A

AREA B

AREA A

AE-123B

F1

AE-123B

F5

A R

EA

C

A R

EA

B

A R

EA

C

A R

EA

B

N2-100A

N2-102B

N2-100B

N2-99B

N2-50A

N2-53A

N2-49

N2-48A

N2-53D

N2-53C

N2-50B

N2-48

N2-54A

N2-54B

N2-53B

N2-98

N2-99A

C2-47

N2-97

N2-50

HOUSEKEEPING

N2-55

ELEVATOR

LOBBY

C2-45

CORRIDOR

N2-90

EX. TOILET

C2-106

C1

AE-301

TYP.

N

C2

AE-301

10A

7A14

A1

A2

A1

A2

A7

A7

A7

A7

A7

E1

AE-301

C1

AE-301

TYP.

AE-131

D1

A3

A1

A5

A A

A A

A

'-2

/2

8' -6

9'-0 1/4"

4'-0"

A

A

A

A

5' -1

1" A

6' -1

1"

'-3

A

A

A

7'-11 1/2"

8' -6

EX. OFFICE

A

A

N2-98B

CLEAR

4'-0"

C2-105B

C2-105A

CORRIDOR

C2-32

5/

8"

7/ 8"

2 1/4"

C COLUMNL

C COLUMNL

C COLUMNL

AF-401

E4

A14

A14

46'-7"

9'-0"

PO VUTSRQ

Q.8 S.2 S.9

EX. ELEC

C2-39C

EX.

WELLNESS

OFFICE

C2-39A

EX. CARDIAC

REHAB

OFFICE

C2-40A

EX. OT CLINIC

C2-43

EX. CARDIAC

REHAB

C2-40

EX.

RECREATION

THERAPY

C2-39

EX. MECH

C2-39B

ELEC

STAIR #3

C2-30

ULTRASOUND

WAITING

C2-29

WOMEN'S

TOILET

C2-28

C2-33C

BARIATRIC

ULTRASOUND

EXAM 2

C2-33B

TOILET

C2-31C

C2-31B

ULTRASOUND

EXAM 2

C2-31B

C2-33E

BARIATRIC

ULTRASOUND

EXAM 1

C2-33E

BARIATRIC

TOILET

C2-33C

11'-8"

ULTRASOUND

TECHS / FILES

C2-30

C2-31D C2-31A

ULTRASOUND

EXAM 1

C2-31A

C2-33D

SOILED

UTILITY

C2-33D

N.M.

SECRETARY

C2-34

MULTIPURPOSE

ROOM

C2-35A

N.M.

SUPERVISOR

OFFICE

C2-35 C2-35A

STAFF

TRAINING

C2-24A

REHAB

OFFICE

SUPERVISOR

C2-24B CHIEF OFFICE

C2-24C

REHAB &

PROSTH.

OFFICE

C2-24D

PET CT

WAITING

C2-25

REHAB VIST.

ASSIST.

OFFICE

C2-23

C2-41B

MEN'S TOILET

C2-41B

WOMEN'S

TOILET

C2-41A

OT CLINIC

OFFICE

C2-42

CLEAN

HOLDING

C2-31D

SOILED

HOLDING /

UTILITY

LIMIT OF WORK

C2-35C2-41AC2-43A C2-42

C2-43C

CLOS.

C2-42A

EX. TOILET

C2-38

EX. TOILET

C2-37

EX.

VESTIBULE

C2-36

AE-123A

F1

A R

EA

C

A R

EA

B

A R

EA

C

A R

EA

B

B

C2-32A

C2-24C C2-24DC2-24BC2-24A

C2-31E

C2-26

C2-42A

C2-46A

C2-23

C2-43B

C2-25

C2-34

C2-35B

C2-33B

CORRIDOR

C2-32

CORRIDOR

C2-32A

ELEC

C2-27

MECH

C2-27A

CORRIDOR

C2-26

C1

C2

N

C2-28

A4

C1

AE-301

TYP.

C1

AE-301

TYP.

C1

AE-301

TYP.

C1

AE-301

TYP.

10 10 10

'-1

5/

8" 6'

-1

1/ 2"

H O

LD

8' -0

8'

-0

9'

-4

6'-8"

7'-9"

A

A

A

A A

7'-10" 7'-11" 19'-0"

A A

6'-6 5/8"

8'-9 1/2"

2'-3"+/- A

A

A

A

A

A

A

1' -5

4' -5

/4

A

A A

5' -4

9' -9

10'-0"

A A

A

9'-10"

C2-24E

BARIATRIC

TOILET

C2-33A

C2-33A

6' -5

A

SILVER

ELEVATORS

EX. JANITOR

C2-44

EX. PASSAGE

C2-50

EX. LOBBY

C2-44B

EX. ELEC.

C2-43A

10'-1 3/8" C2-31C

AF-401

E4

'-5

1/ 2"

1/

2"

'-8

/2

8' -9

/4

'-0

7"2

/4

'-1

1"

'-9

/8

7/ 8"

8' -0

5"

'-1

3/

4" 1'

-0

/8

1' -0

/8

1. SEE AE-121 FOR ARCHITECTURAL GENERAL NOTES

1. ALL PARTITIONS TO BE TYPE 5 UNLESS INDICATED OTHERWISE.

2. ALL CORRIDOR PARTITIONS TO BE TYPE 8 UNLESS INDICATED OTHERWISE.

3. ALL COLUMN ENCLOSURES TO BE PARTITION TYPE 2 UNLESS INDICATED

OTHERWISE.

4. THE PARTITION TAG INDICATES THE TYPE OF PARTITION FROM CORNER TO CORNER

UNLESS INDICATED OTHERWISE.

5. SEE PARTITION TYPES ON SHEET AE-121 FOR ADDITIONAL INFORMATION.

6. ALL GYPSUM WALLBOARD TO BE MOISTURE RESISTANT.

EXISTING ONE HOUR SMOKE BARRIER

EXISTING PARTITION TO BE REMOVED

EXISTING PARTITION TO REMAIN

EXISTING TWO HOUR SMOKE BARRIER

TYPICAL ONE HOUR SMOKE BARRIER

TYPICAL NON RATED PARTITION

TYPICAL ONE HOUR RATED PARTITION

TYPICAL FURRING

TYPICAL NON RATED SMOKE PARTITION

TEMPORARY PARTITION

10A

T

A13

DEDUCT ALTERNATE NO. 1: Revise finish ceiling systems, light fixtures and associated work in corridors. Refer to sheet AE-125 for alternate. Decision on alternate to be confirmed with VA at time of mock-up.

King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406

2520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 120 www.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.com f: 610.755.6564f: 610.755.6564f: 610.755.6564f: 610.755.6564 t: 610.755.6464t: 610.755.6464t: 610.755.6464t: 610.755.6464

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

VA Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Project Number Scale

Structural Engineer

One East Uwchlan Avenue Suite 403 Exton, PA 19341 Tel (484) 475-2180 Fax (484) 475-2181

MacIntosh Engineering

MEP Engineer

102 Highland Avenue Clarks Summit, PA 18411 Tel (570) 586-4334 Fax (570) 587-8164

Highland Associates

Haz-Mat Consultant

1047 North Park Road P.O. Box 6307 Reading, PA 19610-0307 Tel (610) 621-2000 Fax (610) 621-2001

SSM Group, Inc.

of 59

As indicated

1111 East End Blvd, Wilkes-Barre, PA 18711

RENOVATE WOUND CARE CLINIC

JP EN

SECOND FLOOR ARCHITECTURAL AND DIMENSION

PLAN

09/01/11

AE-122

100% CONSTRUCTION DOCUMENTS - ISSUED FOR BID

FULLY SPRINKLERED

3436 693-09-129

1/8" = 1'-0" B2

PARTIAL 2ND FLOOR ARCHITECTURAL AND DIMENSION PLAN AREA A

1/8" = 1'-0" F1

PARTIAL 2ND FLOOR ARCHITECTURAL AND DIMENSION PLAN AREA B

1/8" = 1'-0"

F2

PARTIAL 2ND FLOOR ARCHITECTURAL AND DIMENSION PLAN AREA C

1/32" = 1'-0" B5

AREAS TO RECEIVE PARTITION TYPE WL

Revisions Date

N PLAN NORTH

AREA C

KEY PLAN

AREA A

AREA B

PO VU

TSRQ

Q.8 S.2 S.9

BARIATRIC

ULTRASOUND

EXAM 1

ULTRASOUND

EXAM 2

TOILET

ULTRASOUND

EXAM 1

CLEAN

HOLDING

ULTRASOUND

TECHS / FILES

BARIATRIC

ULTRASOUND

EXAM 2 BARIATRIC

TOILET

SOILED

UTILITY

N.M.

SECRETARY

MULTIPURPOSE

ROOM

ULTRASOUND

WAITING

WOMEN'S

TOILET

N.M.

SUPERVISOR

OFFICE

STAIR # 2

MECHELEC

EX. TOILET

EX. TOILET

MEN'S TOILET

WOMEN'S

TOILET

OT CLINIC

OFFICE

CLOS.

PET CT

WAITING

REHAB &

PROSTH.

OFFICE

CHIEF OFFICEREHAB

OFFICE

SUPERVISOR

STAFF

TRAINING

REHAB VIST.

ASSIST.

OFFICE

EX.

RECREATION

THERAPY

EX. CARDIAC

REHAB

EX. CARDIAC

REHAB

OFFICE

EX.

WELLNESS

OFFICE

EX. MECH

EX. ELEC

EX.

VESTIBULE

EX. OT CLINIC

CORRIDOR

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0" A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

N

7' -1

0"

8'-7"

A.F.F.7' - 10"

A

1' -3

/2

AA A

1' -8

A

6' -0

6' -0

6' -3

" 3' -6

1' -5

2' -8

/8

3' -2

/8

3'-5"

C5

C5

C5

C5

C5

C5

A.F.F.8' - 0"

A.F.F.8' - 0" A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.9' - 9" A.F.F.9' - 9" A.F.F.9' - 9"

A.F.F.8' - 0" A.F.F.8' - 0"

A.F.F.9' - 9"

A.F.F.8' - 0"

A.F.F.7' - 10"

A.F.F.9' - 9"

A.F.F.8' - 0"

A.F.F.7' - 10"

3' -6

/4

C4

C2

E8

AE-402

F4

AE-402 E6

AE-402

F5

AE-402

E6

AE-402

C2

C3

C2

C3

C3

C3

C1

BARIATRIC

TOILET

2'-6"

A.F.F.7' - 10"

1'-2 7/8"1'-3 1/4"

1' -5

/8

1'

-8

/2

- 3

'-2

/4

6' -0

5'

-4

A.F.F.8' - 0"

AEQ EQ

6'-0" 6'-0" 5'-10 1/4"

A

EQ EQ

F7

AE-402

TYP.

A R

EA

C

A R

EA

B

A R

EA

C

A R

EA

B

F5

AE-402

A.F.F.7' - 10" A.F.F.7' - 10" A.F.F.7' - 10"A.F.F.7' - 10"

A.F.F.7' - 10"

A.F.F.8' - 0"A.F.F.8' - 0"A.F.F.8' - 0"

E Q

E Q

5' -3

C7

A

EQ. A 6'-0" EQ. A

6"

EQ EQ

E Q

. B E

Q . B

OF LIFT

A.F.F.7' - 10"

A.F.F.7' - 10" A.F.F.7' - 10"

C9

C10

C10

C10

MKJ L

MECH

IT ROOM ELEVATOR

LOBBY

EX. TOILET

WAITING

SILVER

ELEVATORS

ELECELEC

STAIR #3

SOILED

HOLDING /

UTILITY

RECEPTIONIST

W.C.

BARIATRIC

TREATMENT

W.C.

TREATMENT

W.C. OFFICE

EMG

W.C. UV /

WHIRLPOOL

ORTHOTICS

TREATMENT

ORTHOTICS

STORAGE/REPAIRS

PROSTHETICS

SUPERVISOR

OFFICE

ORTHOTICS

OFFICE

PROSTHETICS

STORAGE

PROSTHETICS

PURCHASING

OFFICE

EX. CT

WAITING

EX. FILES HOUSEKEEPING

STORAGE

MEN'S TOILET

WOMEN'S

TOILET

CORRIDOR

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

8'-2"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

3'-10"

A.F.F.8' - 0"

0"

N

A.F.F.9' - 0"

A.F.F.8' - 6"

C2

AE-301

A

11 1/4"

1'-0 1/2"

A

A

A

A

A

1'-10"

2'-0"

5'-4"

6'-3"

6'-0"

A

A

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.8' - 0"

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.9' - 9"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.7' - 10"

A.F.F.7' - 10" A.F.F.8' - 0"

C2

9"

A.F.F.7' - 10"

3' -6

E6

AE-402

A.F.F.7' - 10"

F1

AE-402

F2

AE-402

PHONES

6'-0"

6'-0"

A A

EX. OFFICE

E1

AE-402

TYP.

E2

AE-402

A R

EA

C

A R

EA

B

A R

EA

C

A R

EA

B

AREA B

AREA A

AREA B

AREA A

F4

AE-402

E1

AE-402

TYP.

E1

AE-402

TYP.

C6

C6

C6

C6

C6

2' -1

0"

9'-8"

A.F.F.8' - 0"

A.F.F.8' - 0"

EQ EQ

A.F.F.9' - 0"

E3

AE-402

TYP.

E3

AE-402

TYP.

EQ EQ

E3

AE-402

TYP.

C8

C8

C8

9'-4 1/8"

C10

C10

C10

C10

C10

C10

C10

C10

C10

MKJ L

N

A.F.F.8' - 0"

A.F.F.8' - 0"

LIMIT OF WORK

AREA B

AREA A

AREA B

AREA A

1. CONTRACTOR TO INSTALL CEILING IN ALL ROOMS AS SHOWN IN THE

REFLECTED CEILING PLAN AND AS INDICATED IN THE FINISH SCHEDULE TO RECEIVE

NEW CEILINGS. FOLLOW CEILING SYMBOL LEGEND FOR CEILING LAYOUT.

2. WHERE NEW CEILING ARE INDICATED, REMOVE ALL EXISTING CEILINGS TO

ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH AND REPAIR EXISTING

WALLS AS REQUIRED TO INSTALL NEW FINISHES.

3. REMOVE ALL EXISTING CEILINGS TO ALLOW FOR PROPER INSTALLATION OF

MECHANICAL, PLUMBING AND ELECTRICAL WORK. PATCH AND REPAIR EXISTING

CEILINGS TO MATCH EXISTING OR INSTALL NEW CEILINGS AS INDICATED ON THE

REFLECTED CEILING PLAN AND/OR FINISH PLAN.

4. THE CONTRACTOR MUST SUBMIT TO ARCHITECT COORDINATED REFLECTED

CEILING PLAN FOR REVIEW AND APPROVAL INCORPORATING LIGHT FIXTURES,

SPRINKLER HEADS AND MECHANICAL LAYOUTS.

5. REFER TO HVAC DRAWINGS FOR LOCATION OF SUPPLY DIFFUSERS, RETURN

GRILLS.

6. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF LIGHT FIXTURES AND

CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, FIRE ALARM DEVICES, NURSE

CALL DOME LIGHTS, ETC.

7. SPRINKLER HEADS ARE NOT INDICATED ON THE REFLECTED CEILING PLANS.

SPRINKLER HEADS TO ALIGN WITH EACH OTHER IN BOTH NORTH/SOUTH AND

EAST/WEST DIRECTIONS WHERE THEY OCCUR IN A SINGLE SPACE. SIMILARLY FOR

OTHER CEILING DEVISES. THE CONTRACTOR SHALL INSTALL SUFFICIENT SPRINKLER

HEADS IN ALL SPACES TO PROVIDE (100%) COVERAGE AS DEFINED IN NFPA 13.

REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS OF THE SPRINKLER HEADS.

8. THE CONTRACTOR SHALL PROVIDE ACCESS PANELS IN GYPSUM BOARD

CEILINGS AND IN HARD SURFACE SOFFITS SO THAT THE ARCHITECT, THE STATE AND

LOCAL OFFICIALS CAN INSPECT RATED WALLS. THESE ACCESS PANELS SHALL BE

LOCATED AS NECESSARY TO VIEW ALL SURFACES OF THE RATED WALL(S).

9. ALL ACT CEILINGS (ON FLOOR 2) ARE 9'-9" U.N.O.

10. ALL GWB SOFFIT CEILINGS ARE 9'-3" U.N.O AND PT-6 @ CEILINGS AND THEIR

SOFFIT FASCIAS W/ GWB.

11. WHERE SUPPORT WIRES FOR ACOUSTICAL CEILING GRID CANNOT BE

INSTALLED VERTICALLY, THE CONTRACTOR SHALL PROVIDE A UNISTRUT BENEATH

THE OBSTRUCTION AS TO PERMIT WIRES TO BE VERTICALLY ATTACHED TO THE

UNISTRUT.

12. SPRINKLER HEADS TO ALIGN WITH EACH OTHER IN BOTH NORTH/SOUTH AND

EAST/WEST DIRECTIONS WHETHER THEY OCCUR IN A SINGLE SPACE. SIMILARLY

FOR OTHER CEILING DEVICES, ALL SPRINKLER HEADS ARE DRAWN TO SHOW DESIGN

INTENT WHERE INDICATED. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING

THE CORRECT NUMBER OF SPRINKLER HEADS AS REQUIRED BY APPLICABLE CODES.

CEILING CONTRACTOR TO COORDINATE CEILING LAYOUT IN ROOM WITH

EQUIPMENT SUPPORT RAILS AND OTHER CEILING MOUNTED EQUIPMENT.

CONTRACTOR TO SUPPLY AND INSTALL UNISTRUT SUPPORT SYSTEM

EQUIPMENT RAILS, MOUNTING PLATES ETC. TO SUPPORT PATIENT LIFTS. SEE

STRUCTURAL DRAWINGS AND EQUIPMENT VENDOR DRAWINGS FOR MORE

INFORMATION. SEE ALSO DETAILS E1 AND E2/AE-404.

ALL CURTAIN TRACKS AND I.V. TRACKS SHALL BE SUPPORTED INDEPENDENT

OF THE CEILING AND SUSPENSION SYSTEM. SEE DETAILS ON SHEET AE-404.

RELOCATE EXISTING LIGHT FIXTURES AND DIFFUSERS TO INSTALL NEW LIFT.

FURNISH AND INSTALL NEW CEILING TILE IN EXISTING GRID.

BEAM END RETAINING CLIP SIDE OF CEILING SYSTEM.

MATCH EXISTING CEILING HEIGHT, GRID AND TYPE.

ALIGN CENTERLINE OF FIXTURE W/ CENTERLINE OF WALL PER ELEVATION

E1/AE-201

MOCK UP AREA. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

SHADE DEVICE. SEE SPECIFICATION FOR ADDITIONAL INFORMATION

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

E

DENOTES GWB SOFFIT/CEILING

CEILING HEIGHT DESIGNATION

(WHEN HEIGHT VARIES FROM

TYPICAL)

INTRAVENOUS TRACK

OVER BED LIGHT FIXTURE

EXAM LIGHT

FLUORESCENT LIGHT FIXTURE

CURTAIN TRACK

DISC LIGHT IN ALL STAIRWELLS -

WALL MOUNTED

WALL SCONCE

FLUORESCENT DIRECT/

INDIRECT LIGHT

EQ. A EQ. A

E Q

. B E

Q . B

PENDANT MOUNTED LIGHT TUBE

CONTINUOUS FLUORESCENT

TUBE AND BALLAST CONCEALED

INDIRECT FIXTURE

EXIT SIGN (SHADED AREA

INDICATES DIRECTION OF

EGRESS)

SUPPLY DIFFUSER

INCANDESCENT DOWNLIGHT

FLUORESCENT PARABOLIC LIGHT

FIXTURE

RETURN GRILL

LIGHT - STEM MOUNTED

RECESSED FLUORESCENT WALL

WASHER

PENDANT MOUNTED LIGHT

FLUORESCENT DOWN LIGHT

FIXTURE

RADIANT PANEL

UNDER CABINET TASK LIGHT

CEILING CONTRACTOR TO MEASURE EACH CEILING AREA AND ESTABLISH A CEILING

LAYOUT TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH ROOM. AVOID USE

OF LESS-THAN 6" TILES.

RECESSED COVE LIGHT

A.F.F.10' 6"

SD SLT

SD SLT SD SLT

TYPICAL DOUBLE DEVICE MOUNTINGTYPICAL SINGLE DEVICE MOUNTING

LT : LIGHT FIXTURE S : SPEAKER SD : SMOKE DETECTOR

EQ EQ EQEQ EQ

EQ EQ

E Q

E Q

EQ EQ EQ

E Q

E Q

E Q

E Q

E Q

E Q

DEDUCT ALTERNATE NO. 1: Revise finish ceiling systems, light fixtures and associated work in corridors. Refer to sheet AE-125 for alternate. Decision on alternate to be confirmed with VA at time of mock-up.

King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406King of Prussia, PA 19406

2520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 1202520 Renaissance Boulevard, Suite 120 www.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.comwww.hdp#architects.com f: 610.755.6564f: 610.755.6564f: 610.755.6564f: 610.755.6564 t: 610.755.6464t: 610.755.6464t: 610.755.6464t: 610.755.6464

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

VA Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Project Number Scale

Structural Engineer

One East Uwchlan Avenue Suite 403 Exton, PA 19341 Tel (484) 475-2180 Fax (484) 475-2181

MacIntosh Engineering

MEP Engineer

102 Highland Avenue Clarks Summit, PA 18411 Tel (570) 586-4334 Fax (570) 587-8164

Highland Associates

Haz-Mat Consultant

1047 North Park Road P.O. Box 6307 Reading, PA 19610-0307 Tel (610) 621-2000 Fax (610) 621-2001

SSM Group, Inc.

of 59

As indicated

1111 East End Blvd, Wilkes-Barre, PA 18711

RENOVATE WOUND CARE CLINIC

JP EN

SECOND FLOOR REFLECTED CEILING PLAN

09/01/11

AE-124

100% CONSTRUCTION DOCUMENTS - ISSUED FOR BID

FULLY SPRINKLERED

3436 693-09-129

1/8" = 1'-0" F3

PARTIAL 2ND FLOOR REFLECTED CEILING PLAN - AREA C

1/8" = 1'-0" F1

PARTIAL 2ND FLOOR REFLECTED CEILING PLAN - AREA B

1/8" = 1'-0" B3

PARTIAL 2ND FLOOR REFLECTED CEILING PLAN - AREA A

C6C6C6

Revisions Date

1/2" FABRIC WRAPPED TACKABLE

PANEL

3" GROMMET (1) PER MONITOR

LOCATION AND (1) AT RETURN

2 X 2 CONTINUOUS ANODIZED

ALUMINUM ANGLE

1/2" CORE WITH PLASTIC LAMINATE

FINISH

RACEWAY

GENERAL NOTE:

RAKKS MODEL EH-1209 FOR USE ON COUNTERS UP TO 13" D

RAKKS MODEL EH-1212 FOR USE ON COUNTERS UP TO 18" D

RAKKS MODEL EH-1818 FOR USE ON COUNTERS UP TO 25" D

RAKKS MODEL EH-1824 FOR USE ON COUNTERS UP TO 30" D

DUPLEX RECEPTACLE

MONITOR (N.I.C.)

NOVA FLAT PANEL

DISPLAY SYSTEM

(MONITOR BRACKET,

TRIM, GLASS &

KEYBOARD TRAY)

3/4" PLYWOOD

3/4" QUARTZ STONE

1'-3"

3'- 6"

2'-6"

3/4" QUARTZ STONE

ON 3/4" PLYWOOD

3/4" QUARTZ STONE

ON 3/4" PLYWOOD

2'- 6"

PROFILE OF RECEPTION DESK IN

FOREGROUND

STAINLESS STEEL FURNITURE LEG

3/4" QUARTZ STONE

3"

1'-6"

U.

N.

O.

O

N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

VE

RI

FY

CE

NT

ER

LI

NE

O

F

DR

AW

ER

P

UL

L

3'

- 2

STUD WALL

CONSTRUCTION

PLASTIC LAMINATE DRAWER FACE

PLASTIC LAMINATE SHELF WITH 3/4"

PLYWOOD CORE

5'- 8"

1'-4"

RESILIENT BASE

METAL DRAWER GUIDE

WIRE PULL

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

MDF GUSSET BACKER

PLASTIC LAMINATE FASCIA

PLASTIC LAMINATE DOOR FACE

PLASTIC LAMINATE PANEL

2X4 WOOD BLOCKING2X4 WOOD BLOCKING

PLASTIC LAMINATE SHELF

3/4" PLASTIC LAMINATE REMOVABLE

PANEL

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

BLOCKING

8" 10" 6"

1/

2"

1/ 2"

1'- 6"

9"

2'-

2'-1"

7" 2'-

3"

STUD WALL

CONSTRUCTION

RESILIENT BASE

MELAMINE BACKER PANEL

SOLID SURFACE POLYMER

COUNTERTOP WITH A TOP

MOUNTED SINK AND 4" SOLID

SURFACE BACKSPLASH

PLASTIC LAMINATE FASCIA

MDF GUSSET BACKER

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

MELAMINE BACKER PANEL

PLASTIC LAMINATE SHELF WITH 3/4"

PLYWOOD CORE

PLASTIC LAMINATE DOOR FACE

2 X 2 CONTINUOUS ANODIZED

ALUMINUM ANGLE

CONTINUOUS FLUORESCENT TASK

LIGHT

VE

RI

FY

U.

N.

O.

O N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

1/

2"

U.N.O. ON ELEVATIONS

SEE CABINET DIMENSIONS LEGEND

PROVIDE FLUSH MOUNTED

CONCEALED HINGES FOR ALL

CABINET DOORS

GENERAL NOTE:

RAKKS MODEL EH-1209 FOR USE ON COUNTERS UP TO 13" D

RAKKS MODEL EH-1212 FOR USE ON COUNTERS UP TO 18" D

RAKKS MODEL EH-1818 FOR USE ON COUNTERS UP TO 25" D

RAKKS MODEL EH-1824 FOR USE ON COUNTERS UP TO 30" D

U.

N.

O.

O

N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

U.N.O. ON ELEVATIONS

SEE CABINET DIMENSIONS LEGEND

1/

2"

SOLID SURFACE POLYMER

COUNTERTOP WITH 4" SOLID SURFACE

BACKSPLASH

3" GROMMET (1) PER MONITOR

LOCATION AND (1) AT RETURN

METAL COUNTER SUPPORT BRACKET

(SIZE ACCORDING TO

MANUFACTURERS SIZING

REQUIREMENTS)

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

CONTINUOUS J SHAPED WIRE HANGER

2 X 2 CONTINUOUS ANODIZED

ALUMINUM ANGLE

RESILIENT BASE

SLIDING KEYBOARD AND MOUSE TRAY

WAITING RM SIDE

2 X 4 STUD

CHAIR RAIL (CR-1)

DH-1

DG-1

METAL DRAWER GUIDE

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

PLASTIC LAMINATE SHELF WITH 3/4"

PLYWOOD CORE

PLASTIC LAMINATE DOOR FACE

SOLID SURFACE POLYMER

COUNTERTOP WITH 4" SOLID SURFACE

BACKSPLASH

STUD WALL

CONSTRUCTION

0"

3/ 8"

5" U.

N.

O.

O N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND MELAMINE BACKER PANEL

MULTIPLE HOLE WITH METAL PINS

SHELF SUPPORT

1'-6"

PLASTIC LAMINATE DRAWER FACE

RESILIENT BASE

2X4 WOOD BLOCKING2X4 WOOD BLOCKING

4"

U.N.O. ON ELEVATIONS

SEE CABINET DIMENDION LEGEND

SOLID POLYMER SURFACE EDGE

BAND

SEE SECTION F4 FOR TYPICAL KEYNOTES AT THIS SECTION

2'-6"

3/4" PLASTIC LAMINATE 3/4" MDF

3/4" QUARTZ STONE

PROFILE OF RECEPTION DESK BEYOND

2'- 6"

2'- 8"

4"

A

8"

STUD WALL

CONSTRUCTION

1/

2" 3/

8"5"

SEE SECTION B1 FOR TYPICAL KEYNOTES AT THIS SECTION

SOLID SURFACE POLYMER

COUNTERTOP WITH AN INTEGRAL

SINK AND 4" SOLID SURFACE

BACKSPLASH

U.

N.

O.

O

N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

U.N.O. ON ELEVATIONS

SEE CABINET DIMENSIONS LEGEND

1"

SPRING CATCH

4"

SOLID SURFACE POLYMER

COUNTERTOP WITH A TOP

MOUNTED SINK AND 4" SOLID

SURFACE BACKSPLASH

VE

RI

FY

U.

N.

O.

O N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

1/

2"

PLASTIC LAMINATE END PANEL

U.N.O. ON ELEVATIONS

SEE CABINET DIMENSIONS LEGEND

SEE SECTION A1 FOR TYPICAL KEYNOTES AT THIS SECTION

STUD WALL

CONSTRUCTION

SEE SECTION B2 FOR TYPICAL KEYNOTES AT THIS SECTION

1/

2"

U.

N.

O.

O

N

EL

EV

AT

IO

NS

SE

E

CA

BI

NE

T

DI

M

EN

SI

ON

S

LE

GE

ND

4"

U.N.O. ON ELEVATIONS

SEE CABINET DIMENSIONS LEGEND

PLASTIC LAMINATE FASCIA

MDF GUSSET BACKER

3/8" HEX HEAD BOLT WITH WALL

TOGGLE FASTENED TO 6" W X 18

GAUGE GALVANIZED STEEL PLATE

SECURED TO A MINIMUM OF 3 STUDS

PLASTIC LAMINATE SHELF WITH 3/4"

PLYWOOD CORE

MELAMINE BACKER PANEL

RESILIENT BASE

1'-8"

PLASTIC LAMINATE PANEL

STUD WALL

CONSTRUCTION

PROVIDE FLUSH MOUNTED

CONCEALED HINGES FOR ALL

CABINET DOORS

2X4 WOOD BLOCKING2X4 WOOD BLOCKING

1. SEE AE-201 FOR MILLWORK GENERAL NOTES AND LEGENDS

CLEAR

10"

/4

BLACK GRANITE

3/4" PLYWOOD

2 X 4 STUD

RECEPTION SIDE TOILET ROOM SIDE

ADHERE TO BASE

PLYWOOD BASE

ANCHORED TO FLOOR

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

VA Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS:

Office of Facilities

Management

Project Number Scale

Structural Engineer

One East Uwchlan Avenue Suite 403 Exton, PA 19341 Tel (484) 475-2180 Fax (484) 475-2181

MacIntosh Engineering

MEP Engineer

102 Highland Avenue Clarks Summit, PA 18411 Tel (570) 586-4334 Fax (570) 587-8164

Highland Associates

Haz-Mat Consultant

1047 North Park Road P.O. Box 6307 Reading, PA 19610-0307 Tel (610) 621-2000 Fax (610) 621-2001

SSM Group, Inc.

of 59

As indicated

1111 East End Blvd, Wilkes-Barre, PA 18711

RENOVATE WOUND CARE CLINIC

JP EN

CASEWORK DETAILS

09/01/11

AE-401

3436 693-09-129

1 1/2" = 1'-0"

F4 SECTION @ RECEPTION DESK

1 1/2" = 1'-0"

F5 SECTION @ WARDROBE

1 1/2" = 1'-0"

B3 SECTION @ SINK BASE CABINET - ADA ACCESSIBLE

1 1/2" = 1'-0"

B1 SECTION @ UPPER CABINET

1 1/2" = 1'-0"

D2 SECTION @ WORK COUNTER

1 1/2" = 1'-0"

B2 SECTION @ TYPICAL BASE CABINET

1 1/2" = 1'-0"

F2 SECTION @ RECEPTION DESK

1 1/2" = 1'-0"

B4 SECTION @ TYPICAL BASE CABINET

1 1/2" = 1'-0"

B7 SECTION @ UPPER CABINET

1 1/2" = 1'-0"

D1 SECTION @ OPEN SHELVING BASE CABINET

1 1/2" = 1'-0"

F6 SECTION @ FULL HEIGHT OPEN SHELVING CABINET

1 1/2" = 1'-0"

D4 SECTION AT GLASS PONY WALL IN WAITING

Revisions Date

TOILET SCREEN

VHAWBPKRYNIJ

Polygon

Typewritten Text

Polygon

VHAWBPKRYNIJ

Text Box sample sections applicable for this design/build project.

VHAWBPKRYNIJ

Line

1. DOOR NUMBERING MAY NOT BE SEQUENTIAL. DOORS ARE NUMBERED TO MATCH

THE ROOM NUMBERING.

2. ALL FRAMES SHALL BE CAULKED CONTINUOUSLY TO WALL.

3. WHEREVER THERE IS A CRACK LEFT BETWEEN THE BOTTOM OF DOOR FRAME AND

THE FINISH FLOOR, THE CONTRACTOR SHALL PROVIDE CAULKING TO SEAL CRACK.

4. ALL THRESHOLDS SHALL CONFORM TO THE REQUIREMENTS OF THE MOST

CURRENT EDITION OF ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES,

THE AMERICAN WITH DISABILITIES ACT AND CHAPTER 11 OF THE BUILDING CODE.

5. NON-RATED DOORS MAY BE UNDERCUT 3/4” MAXIMUM. DOORS IN RATED WALLS

SHALL NOT BE UNDERCUT.

6. DOORS SCHEDULED TO HAVE A FIRE RATING LABEL SHALL HAVE A METAL LABEL

PERMANENTLY AFFIXED TO BOTH THE DOOR AND FRAME. A VINYL LABEL AND

EMBOSSED LABEL IN THE FRAME IS UNACCEPTABLE.

7. THE CONTRACTOR SHALL VERIFY THAT CLOSERS AND OTHER HARDWARE WILL

ALLOW THE DOOR TO OPEN 180 DEGREES WHEN SUCH DOOR SWINGS ARE INDICATED

ON THE FLOOR PLAN AND / OR THIS SCHEDULE.

8. ALL INTERIOR DOORS SHALL BE SOLID CORE, PRE-FINISHED UNLESS OTHERWISE

NOTED IN THE SPECIFICATION.

9. ALL INTERIOR DOORS WITH CLOSER SHALL HAVE CLOSERS ADJUSTED TO 5 LB

MAXIMUM PULL FORCE.

10. ALL DOORS WITH CLOSERS SHALL HAVE KICK PLATES.

11. DOORS SCHEDULED TO RECEIVE VIEW PANELS SHALL HAVE WOOD BEAD FRAME

SURROUNDED IN SPECIES TO MATCH DOOR FINISH. FIRE RATED DOORS SHALL HAVE

FIRE RATED WOOD BEAD.

12. ALL FRAMES SHALL BE 16 GAUGE, DOUBLE RABBETED AND PRIMED TO RECEIVE

PAINT.

13. ALL HARDWARE IN RATED DOORS SHALL MEET THE REQUIREMENTS OF NFPA 80.

14. ALL EXAM ROOM ENTRANCE DOORS, EQUIPMENT STORAGE ROOMS, SOILED AND

CLEAN HOLDING ROOMS DOORS SHALL HAVE SWING CLEAR HINGES.

15. THE TOP OF THE BORROWED LIGHTS FRAMES SHALL LINE UP WITH THE TOP OF

THE DOOR FRAMES.

16. MOUNT THE METAL STOPS IN THE BORROWED LIGHTS ON THE “INSIDE” OF THE

SPACE.

17. ALL VIEW PANELS IN 45 MIN OR 20 MIN DOORS SHALL HAVE ¼" WIRE GLASS OR

EQUAL AS SPECIFIED. GLASS SIZE SHALL NOT EXCEED 1296 SQUARE INCHES.

18. ALL OTHER VIEW PANELS OR BORROWED LIGHTS NOT MENTIONED IN NOTE 17 TO

HAVE ¼" TEMPERED GLASS.

1. THROAT SIZE VARIES WITH STUD SIZES AND LAYERS OF GYPSUM WALLBOARD.

2. SEE FLOOR PLANS AND PARTITION TYPES FOR THROAT DIMENSIONS.

3. REFER TO STRUCTURAL DRAWING FOR LINTEL INFORMATION AT MASONRY

OPENINGS.

4. UNLESS NOTED OTHERWISE ALL DOOR FRAMES TO BE 6" FROM PERPENDICULAR

WALLS. CROSS CORRIDOR SMOKE DOORS FRAMES TO BE 4" FROM PERPENDICULAR

WALLS.

1. THROAT SIZE VARIES WITH STUD SIZES AND LAYERS OF GYPSUM

WALLBOARD.

2. SEE FLOOR PLANS AND PARTITION TYPES FOR THROAT DIMENSIONS.

3. APPLIED TUBE STOPS TO BE ¾" AT RATED FRAMES UNLESS OTHERWISE

DETERMINED BY MANUFACTURER LABELING REQUIREMENTS.

4. FIELD VERIFY ALL DIMENSIONS OF EXISTING OPENING.

1. BORROWED LIGHT NUMBER =

2. ELEVATION TYPES:

SEE ELEVATION TYPES "A1" THRU "C2"

3. FRAME SIZE:

OUTSIDE FRAME DIMENSION SHOWN. ROUGH OPENING SIZES TO BE 2" LESS

IN BOTH DIRECTIONS.

4. GLASS TYPE:

WG = 1/4" WIRE GLASS

CTG = 1/4" CLEAR TEMPERED GLASS

FRG = FIRE RATED GLASS

5. FRAME MATERIAL:

HM = HOLLOW METAL

AL = ALUMINUM

6. FRAME FINISH:

WTF = WOOD TRANSPARENT FINISH

MP = METAL, PAINTED

AL = ANODIZED ALUMINUM

8. JAMB:

SEE FRAME DETAILS ON SHEET AE-403

TYPE 1/1A TYPE 3

TYPE 3B -

TYPE 4

TYPE 2

TYPE 5

DOOR SCHEDULE

SEE

S E

E D

O O

R S

C H

E D

U

LE

DOOR SCHEDULE

SEE

DOOR SCHEDULE

SEE

S E

E D

O O

R S

C H

E D

U

LE

S E

E D

O O

R S

C H

E D

U

LE

S E

E D

O O

R S

C H

E D

U

LE

E2 E2E6

F5 F8

F5

DOUBLE EGRESS FRAME

DOUBLE ACTING DOOR

DOOR SCHEDULE

SEE

E2 E6 E2

F1

F1

DOOR SCHEDULE

SEE

D O

O R

S C

H

ED

U

LE

S E

E

E2

S C

H E

D U

LE

S E

E

TO

P

O F

D O

O R

F R

A M

E

TO

A

LI

G

N W

IT

H

E2

SCHEDULE

SEE

TYPE B

SEE SCHEDULE

S C

H E

D U

LE

S E

E

TO

P

O F

D O

O R

F R

A M

E

TO

A

LI

G

N W

IT

HF8

F8

TYPE C1 (C2 OPP HAND)

TO

P

O F

D O

O R

F R

A M

E

TO

A

LI

G

N W

IT

HF8

D2

TYPE A2

4'-3" VIF

6' -1

0" V

IF

D6

D6

TYPE A1

17'-0" VIF

6' -1

/8

" V

IF

D6

D6

1'-6 1/2"

4'-0"

4' -7

F5

F9

E Q

E

QD6 D6

E Q

E Q

SIMILAR; SEE F3/AE-301

1A -

OVERCUT 7"

A9. FRAME FINISH:

WTF = WOOD TRANSPARENT FINISH

MP = METAL, PAINTED

AL = ANODIZED ALUMINUM

HIRA = HIGH IMPACT RESISTANT ACROVYN

10. FRAME DETAILS:

SEE FRAME DETAILS ON SHEET AE-403

11. UL RATING:

20 M ; 45 M ; 1 H ; 1.5 H ; 2 H ; 3 H

12. HARDWARE SET:

SEE HARDWARE SETS IN SPECIFICATIONS.

3. DOOR SIZE:

SEE SCHEDULE FOR WIDTH, HEIGHT AND THICKNESS

4. DOOR MATERIAL:

SCV = SOLID CORE W/ WOOD VENEER FACES

SCA = SOLID CORE ACROVYN FACES

HM = HOLLOW METAL

AL = ALUMINUM & GLASS

5. DOOR FINISH:

WTF = WOOD TRANSPARENT FINISH

MP = METAL PAINTED

AL = ANODIZED ALUMINUM

1. NUMBER: SEE FLOOR PLAN FOR DOOR NUMBER

2. DOOR ELEVATION: SEE TYPES BELOW

TYPE A

TYPE AA

TYPE B

TYPE BB

TYPE D TYPE E

TYPE EE

SEE SCHEDULE

SEE SCHEDULE

S E

E S

C H

E D

U

LE

SEE SCHEDULE

SEE SCHEDULE

2' -9

3'

-6

3" 9"

SEE SCHEDULE

SEE SCHEDULE

SEE SCHEDULE

SEE SCHEDULE

S E

E S

C H

E D

U

LE

6. GLASS TYPE:

WG = 1/4" WIRE GLASS

CTG = 1/4" CLEAR TEMPERED GLASS

7. FRAME ELEVATION:

SEE HOLLOW METAL ELEVATION LEGEND

8. FRAME MATERIAL:

HM = HOLLOW METAL

AL = ALUMINUM

KD = HOLLOW METAL KNOCK DOWN FRAME

TYPE J (SLIDING DOOR)

SCHEDULE

SEE

5/8" MOLD/MOISTURE

RESISTANT TYPE X GYPSUM

WALLBOARD

DOUBLE METAL STUDS AT

JAMB

SEALANT

TH

R

O A

T

HOLLOW METAL BORROWED

LIGHT FRAME

5/8" 2"

1/ 2"1

/1

6"

/1

6"

TH

R

O A

T

1"

OPENING

1/4"…

This is the start of the file's text. The full file is on GovTribe.