S02 - Attachment C - Drawings.pdf

PDF 3 MB Posted

Attached to
Y1DA--Design and Construction of Pharmacy USP 800 Dallas, Texas
Solicitation number
36C77621R0003
Issued by

About this file

This document provides details on an upcoming federal solicitation for design and construction services. The Department of Veterans Affairs seeks proposals for the modification of the Pharmacy Area at the Veterans Affairs North Texas Health Care System in Dallas to meet USP 800 and 797 compounding standards and regulations. Services will include a complete architectural, structural, mechanical, electrical and construction-ready design. The project magnitude is estimated between $1,000,000 and $2,000,000. The solicitation will be advertised as a total Service-Disabled Veteran-Owned Small Business set-aside with a response due date of October 23, 2020 and anticipated period of performance of 180 calendar days from notice to proceed.

View the file

Other files

File Type Posted
S05 - Technical Questions - USP 800 Pharmacy (11-16-2020).docx DOCX document
36C77621R0003 A00002.docx DOCX document
Price Schedule - Pharmacy USP 800.docx DOCX document
S02 - Attachment A - Specification 00 11 21 RFP to DB USP Pharmacy - Dallas TX (10-23-2020 YMR).doc DOC document
36C77621R0003 A00001.docx DOCX document
S02 - Attachment P - Labor Standards Wage Determination.pdf PDF
S02 - Attachment K - Section 01 33 23 Shop Drawings SCE 11-19-2018.docx DOCX document
S02 - Attachment O - Quality Control Plan Requirements.docx DOCX document
S02 - Attachment A - Specification 00 11 21 RFP to DB USP Pharmacy - Dallas TX (10-15-2020 YMR).doc DOC document
S02 - Attachment G - Release of Claims.docx DOCX document
S02 - Attachment J - Section 01 42 19 Reference Standards SCE 11-19-2018.docx DOCX document
S02 - Attachment N - Section 01 57 19 Temporary Environmental Controls SCE 11-19-2018.doc DOC document
S02 - Attachment M - Section 01 35 26 Safety Requirements SCE 11-19-2018.docx DOCX document
S02 - Attachment I - Section 01 32 16 Project Schedules.doc DOC document
S02 - Attachment L - Section 01 32 16 Project Schedules SCE 11-19-2018.doc DOC document
S02 - Attachment H - VHA Master Specifications.docx DOCX document
S02 - Attachment B - SOW Pharmacy USP 800.pdf PDF
S02 - Attachment F - Past Performance Questionnaire.docx DOCX document
S02 - Attachment D - Construction Wage Determination - Dallas County.pdf PDF
36C77621R0003_1.docx DOCX document
S02 - Attachment E - Contractor Safety and Environmental Record Evaluation Form.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

I

I

-------� __Jj

I I

PREPARATION

ROOM I ANTE !ROOM o o

(CLASS 7@ 30 ACR) �� 59,_3 5/8';,,,,

/,,L,/-'----------------------------+=�=-=_=_=----_j---=,,---�--�----,p____.=j ____ _:___ _ _:_.::,_,_�-�------------------------------Wl----J1/

II "\ // II

38'-1 3/4"

I/ 16' -9 5/8"

�,r-.,iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii� t @

STERILE COMPOUNDING

� ,'1 '"' ' F __j I

!)§ F ' F '-

@1:, (i)

4' 4 3/8"

PROJECT NOTES:

PLAN KEYED NOTES:

1. FAN FILTER UNITS/ EXHAUST UNITS TO BE MOUNTED IN UNIT CEILING.

2. 3' SWING DOOR w/ OPTIONAL AUTOMATIC OPERATION IF INDICATED IN

PROPOSAL.

3. HANDS FREE STAINLESS STEEL SINK w/ INTEGRATED EYEWASH UNIT w/ WATER TEMPERING BY PLUMBING CONTRACTOR AS REQUIRED BY

LOCAL MUNICIPALITY.

4. OPTIONAL: STERILE COMPOUNDING ROOM REAL TIME MONITORING SYSTEM

Sa. MAGNEHELIC DEVICE BETWEEN STAGING AREA AND ANTE ROOM TO

MAINTAIN PRESSURE DIFFERENTIAL OF 0.02" TO 0.05" OF WATER.

Sb. MAGNEHELIC DEVICE BETWEEN ANTE ROOM AND STERILE COMPOUNDING ROOM w/ PRESSURE DIFFERENTIAL OF 0.02'' TO 0.05" OF WATER.

Sc. MAGNEHELIC DEVICE BETWEEN ANTE ROOM AND CHEMO ROOM w/ NEG.

PRESSURE DIFFERENTIAL OF -0.01" TO -.03" OF WATER.

Sd. MAGNEHELIC DEVICE BETWEEN STORAGE ROOM AND STAGING w/ NEG.

PRESSURE DIFFERENTIAL OF -0.01" TO -.03" OF WATER.

6a. LAMINAR AIRFLOW HOOD: BY FACILITY.

6b. CHEMO HOOD: BY FACILITY

7. OPTIONAL AIR QUALITY SENSOR MTD. IN WALL @ 48" A.F.F.

8a. NON-VENTED PASS THROUGH BOX w/ INTERLOCKING DOORS.

8b. VENTED PASS THROUGH BOX w/ INTERLOCKING DOORS.

9. PLUMBING CHASE - CHASE, SANITARY AND SUPPLY PLUMBING, ACCESS

PANEL AND HOOKUPS TO BE PROVIDED BY CONTRACTOR AS

REQUIRED.

10. LOW SIDE WALL AIR EXHAUST.

11. PASS-THROUGH REFRIGERATOR BY FACILITY.

FLOOR PLAN

1/4" = 1'-0"

AREA: 587.95 SQ. FT.

VA North Texas Healthcare System 4500 South Lancaster Rd., Dallas, TX 75216

NOT FOR CONSTRUCTION:

Contractor to field verify Conceptual Drawing

[XJ '----I'

[XJ

I

I'-

Future Sterile HD Storage BOX

Existing Layout

Conceptual USP 800 Drawing Model
Main Building Plan
Pharmacyexisting