S02_Attachment-3_817CM3022 Marion Gravesite Expansion-Bid Drawings_Part2.pdf
PDF 14 MB Posted
- Solicitation number
- 36C78621B0010
About this file
This document describes a federal contract opportunity for construction services. The Department of Veterans Affairs National Cemetery Administration is soliciting bids for a gravesite expansion project at the Marion National Cemetery in Marion, Indiana. The scope of work includes removing existing utilities and structures, installing crypts with underdrain and grading, rerouting sewer lines, constructing roadways and curbing, installing concrete monuments, building columbaria units, and other site work. Bids are also requested for the purchase and delivery of 2,020 precast concrete burial vaults. The solicitation includes two add alternates for upgrading the cemetery's irrigation system. The total performance period is 270 calendar days from the notice to proceed. This opportunity is set aside 100% for verified Service-Disabled Veteran-Owned Small Businesses. Bids are due by July 22, 2021 through the Beta SAM website.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06_Attachment 1_Terracon Geotecnical Report - CJ205083 - Gravesite Expansion.pdf | ||
| 36C78621B0010 0002.docx | DOCX document | |
| 36C78621B0010 0001.docx | DOCX document | |
| 36C78621B0010.docx | DOCX document | |
| P07_WD_IN20210006.pdf | ||
| S02_Attachment-2_817CM3022 Marion Gravesite Expnasion-Bid Drawings_Part1.pdf | ||
| S02_Attachment-4_817CM3022 Marion Gravesite Expansion- Bid Specs 05102021.pdf | ||
| S02_Attachment-5_IFB Contractor Cost Estimate Worksheet.xlsx | XLSX spreadsheet | |
| S02_Attachment-1_SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4" PVC
LONG SWEEP
90° BEND
PVC C.O. CAP
TOP OF PVC C.O. CAP SHALL BE PLACED 3" BELOW FINISHED
DECORATIVE GRAVEL SURFACE AS TO HIDE CLEANOUT, BUT
PROVIDE ACCESS AS NEEDED FOR MAINTENANCE.
3" DEEP
AGGREGATE DECORATIVE
AGGREGATE FREE
DRAINING
UNDERDRAIN SECTION
SEE DETAIL 4/LC-103
FINISH GRADE
45° BEND
PVC RISER
CLEANOUT - IN LINE / CONNECTION POINT
WYE
CAST IRON FRAME &
GRATE, MARKED C.O.
OR BLANK
4" PERFORATED PIPE
UNDERDRAIN
SECTION
SEE DETAIL
4/LC-103
CO
CO
CO
CO
TC 838.71
TC 838.79
TC 838.63 TC 838.63
TC 838.71
TC 838.71
TC 838.63
TC 838.80
TC 838.88TC 838.71
TC 838.63 TC 838.80
TC 838.63
TC 838.55
TC 838.63
TC 838.55
TC 838.71
TC 838.60
TC/ME 838.68
TC/ME 838.71
TC/ME 838.79 TC/ME 838.82 TC/ME 838.85 TC/ME 838.88 TC/ME 838.96
TC/ME 838.91
FG 838.39 FG 838.64
FG ???
TC/ME 838.92
TC/ME 838.93
TC/ME 838.95
RIM 838.68
INV 837.18
RIM 838.69
INV 837.19
62LF 4" HDPE PERFORATED DRAINTILE @ 1.00%
62LF 4" HDPE PERFORATED DRAINTILE @ 1.00%
62LF 4" HDPE PERFORATED DRAINTILE @ 1.00%
62LF 4" HDPE PERFORATED DRAINTILE @ 1.00%
RIM 838.63
INV 837.13
RIM 838.64
INV 837.14
15 LF 4" HDPE
PERFORATED
DRAINTILE @ 28.0%
14 LF 4" HDPE
PERFORATED
DRAINTILE @ 30.0%
12LF 4" HDPE
PERFORATED
DRAINTILE @ 33.0%
12LF 4" HDPE
PERFORATED
DRAINTILE @ 33.0%
INV 832.56
RIM 838.46
INV 836.73
RIM 838.54
INV 836.78
EX INV 832.65
INV 832.51
INV 832.42
INV 832.37
INV 836.57
INV 836.56
INV 836.52
INV 836.53
TC 838.88
TC 838.80
TC 838.80
TC 838.72TC 838.72TC 838.64TC 838.55TC 838.55TC 838.55TC 838.47
FG 838.47 FG 838.56
RIM 838.73
INV 836.89
RIM 838.79
INV 836.94
RIM 837.50
INV 830.74
NONWOVEN TYPE 1
DRAINAGE GEOTEXTILE.
OVERLAP 12" MIN
Bc
12" MIN
2" MIN
4" PERFORATED PIPE
SLOPED TO OUTLET AS
SHOWN ON PLANS (0.5% MIN.)
TYPICAL BEDDING SECTION
LINE OF TRENCH
SIDES PER OSHA
REQUIREMENTS
NOTE: ALL PERFORATED PIPE
SHALL BE ENCASED WITHIN
NON-WOVEN GEOTEXTILE FABRIC
& DRAINAGE AGGREGATE
PAVEMENT
SECTION
V A
R
IE
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ c_ co lu m ba riu m g ra di ng
.d w g ed it:
jd ob ia s sa ve d:
5/ 4/
:3
P
M p lo t:5
/4 /2
3:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
KEY MAP
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
COLUMBARIUM GRADING &
DRAINAGE PLAN
LC-103
LEGEND
HP 800.1
R 800.1
800.1
TC 800.1
ME 800.1
FG 800.1
1. SEE STRUCTURAL FOR TOP OF LEDGE
ELEVATIONS (T.O. LEDGE), TOP OF WALL
(T.O. WALL) ELEVATIONS AND TOP OF PIER
(T.O. PIER) ELEVATIONS FOR
COLUMBARIUM WALLS.
2. INSTALL INLET PROTECTION
DOWNSTREAM OF CONSTRUCTION.
3. INSTALL SILT FENCE AT CONSTRUCTION
LIMITS.
4. RESTORE DISTURBED AREA WITH 6"
TOPSOIL, SOD & IRRIGATION
INV 800.1
CO
2 COLUMBARIUM CLEANOUT
SCALE: N.T.S.
1 COLUMBARIUM GRADING & DRAINAGE PLAN
SCALE: 1" = 5'
N
3 PLANTING AREA INLET
SCALE: N.T.S.
GENERAL NOTES
0 5' 10'
EXISTING COLUMBARIUM 1
4 HIGH NICHE COLUMBARIUM
EXISTING COLUMBARIUM 2
5 HIGH NICHE COLUMBARIUM
EXISTING COLUMBARIUM 3
5 HIGH NICHE COLUMBARIUM
EXISTING COLUMBARIUM 4
4 HIGH NICHE COLUMBARIUM
PROPERTY LIMITS
GRADING LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR\
EXISTING SPOT ELEVATION
DRAINAGE ARROW
CONSTRUCTION FENCE
CONSTRUCTION FENCE ON
STANDS
SILT FENCE
NEW STORM SEWER
4" PERFORATED DRAINTILE
EXISTING STORM SEWER
EXISTING 4" PERFORATED
DRAINTILE
NEW STORM STRUCTURES
4" CLEANOUT
AREA INLET
INLET SEDIMENT PROTECTION
SPOT ELEVATION
HIGH POINT
RIM ELEVATION
INVERT ELEVATION
TOP OF CONCRETE
MATCH EXISTING
FINISHED GRADE
6'-0"
IGC
SECTION
CS-5
H Y
D E
R O
A D
2% MIN
4 UNDERDRAIN SECTION
SCALE: N.T.S.
AutoCAD SHX Text 959.4
GRID
GRID
8'-11
2", PRECAST NICHE UNIT (CLOSED) 8'-0", PRECAST NICHE UNIT (OPEN)
2'-0" 2'-0"
4' -0
20'-11 2"
GRID
GRID
GRID
GRID
1' -6
A
B
C
D
E
1 4 8 12 16
2'-0" 8'-11 2" 8'-0" 2'-0"
A
B
C
D
E
17 20 24 28 32
C
O U
R S
E S
8"
47 8"
EQEQ
C
O U
R S
E
EQ
EQ
EQEQ
1 4 8 12 16
A
B
C
D
2'-0" 8'-11 2" 8'-0" 2'-0"
17 20 24 28 32
A
B
C
D
C
O U
R S
E S
8"
47 8"
EQEQ
C
O U
R S
E
EQ
EQ
EQEQ
4' -4
2'-15 8" 5'-05
8" 5'-01 2" 2'-15
8"
20'-51 2"
GRID
GRIDGRID
GRID
GRIDGRID
5'-115 8" 5'-01
2"
4' -0
1'
-0 7 8"
1'-33 4" 2'
-8
EQ.EQ.
3' -1
13 4" 1'
-0 7 8"
1' -3
7 8"
1'-33 4"
7' -4
1 8"
8' -7
3 4"
8"
4'-0"
8"
4'-0"
7' -1
3 8" V
A R
IE
S
8"
8' -7
3 4"
1'-0"
4"
4'-0"
5' -8
7 8" V
A R
IE
S
8"
7' -3
1 4"
1'-0"
4"
5' -1
15 8"
7' -3
1 4"
8"
4'-0"
8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ c_ co lu m ba riu m d et ai ls
.d w jfa hr en ka m d:
5/ 4/
1:
A lo t:5
/4 /2
3:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
COLUMBARIUM DETAILS 1
LC-501
2 COLUMBARIUM PLAN
SCALE: 1/2" =1'-0"
0 2' 4'
1'
LC-501
7 &9
C-103
1 COLUMBARIUM CAP PLAN
SCALE: 1/2" =1'-0"
0 2' 4'1'
NATURAL STONE
CAP (ABOVE)
BRICK VENEER
CIP-CONC. MASONRY
BACKUP
PRECAST NICHE BRICK VENEER (BELOW)
8" JOINT WITH BACKER ROD &
SEALANT BETWEEN STONE CAPS
3 COLUMBARIUM 5-HIGH ELEVATION
SCALE: 1/2" =1'-0"
0 2' 4'1'
5 COLUMBARIUM 4-HIGH ELEVATION
SCALE: 1/2" =1'-0"
0 2' 4'1'
4 COLUMBARIUM 5-HIGH PIER ELEVATION
SCALE: 1/2" =1'-0"
7 COLUMBARIUM 5-HIGH PIER SECTION
SCALE: 1/2" =1'-0"
0 2' 4'1'
C-103
6 COLUMBARIUM 4-HIGH PIER ELEVATION
SCALE: 1/2" =1'-0"
0 2' 4'1'
0 2' 4'1'
C-103
3A C-103
5A
C-103
3B C-103
5B
C-103
C-103
8" JOINT WITH BACKER ROD &
SEALANT BETWEEN PRECAST
NICHE AND BRICK, TYP.
LC-501
NATURAL STONE CAP
BRICK VENEER
NATURAL STONE PANEL
-INCISED 8" TALL
NUMBER AT 1-1/2" DEPTH,
CENTERED, TIMES NEW
ROMAN FONT;
MATCH EXISTING
NATURAL STONE CAP
BRICK VENEER
NATURAL STONE PANEL
-INCISED 8" TALL
NUMBER AT 1-1/2" DEPTH,
CENTERED, TIMES NEW
ROMAN FONT;
MATCH EXISTING
NATURAL STONE CAP
BRICK VENEER
NATURAL STONE PANEL
-INCISED 4" TALL LETTER
AT 1-1/2" DEPTH, TIMES
NEW ROMAN FONT;
MATCH EXISTING
ELEVATION A ELEVATION B
ELEVATION A ELEVATION B
NATURAL STONE CAP
-INCISED 4" TALL
NUMBER AT 38" DEPTH,
TIMES NEW ROMAN FONT
NATURAL STONE CAP
BRICK VENEER
NATURAL STONE PANEL
-INCISED 4" TALL LETTER
AT 1-1/2" DEPTH, TIMES
NEW ROMAN FONT;
MATCH EXISTING
NATURAL STONE CAP
-INCISED 4" TALL
NUMBER AT 38" DEPTH,
TIMES NEW ROMAN FONT
8 COLUMBARIUM 5-HIGH NICHE SECTION
SCALE: 1/2" =1'-0"
0 2' 4'1'
LC-501
8 & 10
LC-501
PRECAST NICHE
CIP-CONC. MASONRY BACKUP,
SEE STRUCTURAL
BRICK VENEER
NATURAL STONE CAP
2" EXPANSION JOINT 3" DEPTH DECORATIVE GRAVEL
CONCRETE PAVEMENT
DRAINAGE ROCK WRAPPED
IN GEOTEXTILE FABRIC
4" DIA. DRAINTILE
CONCRETE PAVEMENT
NATURAL STONE CAP
PRECAST NICHE
MARBLE NICHE COVER
BRICK VENEER
NATURAL STONE CAP
2" EXPANSION JOINT
CONCRETE PAVEMENT
3" DEPTH DECORATIVE GRAVEL
CONCRETE PAVEMENT
DRAINAGE ROCK WRAPPED
IN GEOTEXTILE FABRIC
4" DIA. DRAINTILE
PRECAST NICHE
MARBLE NICHE COVER
BRICK VENEER
NATURAL STONE CAP
9 COLUMBARIUM 4-HIGH PIER SECTION
SCALE: 1/2" =1'-0"
0 2' 4'1'
10 COLUMBARIUM 4-HIGH NICHE SECTION
SCALE: 1/2" =1'-0"
0 2' 4'1'
SS BRICK TIE
SS DOVETAIL BRICK TIE IN SS
SLOT CASTED INTO CIP-CONC.
LC-502
LC-502
LC-502
LC-502
LC-502
LC-502
LC-502
LC-502
S.S. DOVETAIL BRICK TIE IN
S.S. SLOT CASTED INTO
CIP-CONC. CENTER IN PIER
T.O. LEDGE T.O. LEDGE
T.O. PIER
T.O. LEDGE
T.O. LEDGE
T.O. WALLT.O. WALL
8" JOINT WITH BACKER ROD &
SEALANT BETWEEN STONE CAPS
CIP-CONC. MASONRY BACKUP,
SEE STRUCTURAL
BRICK VENEER
SS DOVETAIL BRICK TIE IN SS
SLOT CASTED INTO CIP-CONC.
T.O. PIER
NOTE:
SEE 2/LC-102 FOR
NUMBERING
NOTE:
SEE 2/LC-102 FOR
NUMBERING
8"
1'-10"
INSTALL TYPE 304 STAINLESS STEEL ANCHOR BOLTS, WASHERS & EXPANSION SHIELDS PER
MANUFACTURER RECOMMENDATIONS; FIELD INSTALL & FILL WITH SEALANT, TYP.
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR INSTALLED
STAINLESS
STEEL ROSETTE
2"
1'-8" 11 2"
1' -2
1 2"
1' -3
11 2"
5' -8
1 2"
2"
1' -3
8'-11 2"
5' -8
1 2"
4"
1' -3
3 4"
PRE-CAST CONCRETE COLUMBARIUM NICHE - PROVIDE LIFTING INSERTS,
RE-INFORCING, AND WELD PLATES PER TECHNICAL SPECIFICATIONS
WELD PLATE PER MANUFACTURER & STRUCTURAL
RECOMMENDATIONS & REQUIREMENTS. (TYP.)
2" 11
2"
11 2" 2"
1'-10"
2"
1'-8"11 2"
1' -2
1 2"
1' -3
11 2"
2"
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.)
2"
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR
INSTALLED
2"
1' -3
8'-0"
5' -8
1 2"
4"
1' -3
3 4"
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.)
2" 11
2"
11 2" 2"
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR
INSTALLED
2"
1' -3
8'-0"
5' -8
1 2"
4"
1' -3
3 4"
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.)
2"11
2"
11 2" 2"
2"
STAINLESS
STEEL
ROSETTE
STAINLESS
STEEL
ROSETTE
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR
INSTALLED
STAINLESS
STEEL
ROSETTE
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.)
8'-0"
7' -1
2"
1' -3
4"
1' -3
3 4"
2" 11
2"
11 2" 2"
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR
INSTALLED
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.)8'-0"
7' -1
2"
1' -3
4"
1' -3
3 4"
2"11
2"
11 2" 2"
STAINLESS
STEEL
ROSETTE
1'-10"
PRE-CAST CONCRETE COLUMBARIUM NICHE - PROVIDE LIFTING INSERTS,
RE-INFORCING, AND WELD PLATES PER TECHNICAL SPECIFICATIONS
INSTALL TYPE 304 STAINLESS STEEL ANCHOR BOLTS, WASHERS &
EXPANSION SHIELDS PER MANUFACTURER RECOMMENDATIONS; FIELD
INSTALL & FILL WITH SEALANT, TYP.
7' -1
2"
1'-8"
2"
1' -2
1 2"
1' -3
11 2"
2"
MARBLE NICHE COVERS:
PRE-DRILLED HOLES FOR ATTACHMENT
GOVERNMENT SUPPLIED, CONTRACTOR INSTALLED
STAINLESS STEEL
ROSETTE
WELD PLATE PER MANUFACTURER &
STRUCTURAL RECOMMENDATIONS &
REQUIREMENTS. (TYP.) 8'-11
2"
7' -1
2"
1' -3
4"
1' -3
3 4"
2" 11
2"
11 2" 2"
2"
5 8" TALL INCISED 1-1/2"
DEPTH COLUMBARIUM
SECTION LETTER - CENTER
IN PANEL - BLACK EPOXY
PAINT - FONT TO BE TIMES
NEW ROMAN - MATCH
EXISTING
1'-33 4"
1' -0
7 8"
8"
SECTION
1/
4"
TY
P
1' -0
7 8"
PLAN
ANCHOR NATURAL STONE PANEL
INTO CAST-IN-PLACE CONCRETE
WALL CORE WITH EPOXY COATED
DOWELS WITH NON-SHRINK
GROUT, (2) LOCATIONS, PER
MANUFACTURER
RECOMMENDATIONS.
NOTES:
1. SEE SPECIFICATIONS FOR MORE INFORMATION.
2. SUBMIT SAMPLE OF NATURAL STONE INCLUDING ENGRAVED
LETTERS FOR APPROVAL PRIOR TO CONSTRUCTION.
3. REFER TO SHEET LC-102 FOR COLUMBARIUM NUMBERING PLAN.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ c_ co lu m ba riu m d et ai ls
.d w jfa hr en ka m d:
5/ 4/
1:
lo t:5
/4 /2
3:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
COLUMBARIUM DETAILS 2
LC-502
2 COLUMBARIUM PIER BASE DETAIL
SCALE: 3" =1'-0"
0 6" 9"3"
1 COLUMBARIUM PIER CAP DETAIL
SCALE: 3" =1'-0"
0 6" 9"3"
NATURAL STONE CAP
1/2" DIA. SS DOWEL; SEAL
SS DRIP WATER TIGHT
BACKER ROD AND SEALANT
SS DRIP, SPAN ENTIRE
TOP OF NICHES
BRICK VENEER
4 COLUMBARIUM BASE & GRAVEL STRIP DETAIL
SCALE: 1 1/2" =1'-0"
0 12" 18"6"
3 COLUMBARIUM CAP DETAIL
SCALE: 3" =1'-0"
0 6" 9"3"
NATURAL STONE CAP
6" x 1/2" DIA. SS DOWEL, EPOXY;
SEAL SS DRIP WATER TIGHT
BACKER ROD AND SEALANT
SS DRIP, SPAN ENTIRE
TOP OF NICHES
MARBLE NICHE COVER
PRECAST CONC. NICHE
5"
1"
DRIP EDGE 14"x 14" CONT.
AROUND CAP
4"
1 2"
C
O U
R S
E S
S E
E S
H E
E T
LC
-1
6" x 1/2" DIA. SS
DOWEL, EPOXY
PRECAST CONC.
COLUMBARIUM UNIT
1'-0"
DECORATIVE AGGREGATE,
3" DEPTH MIN.
BACKROD AND SEALANT
THRU WALL FLASHING, FASTEN TO CIP
CONC. WITH SS CONT. TERMINATION BAR
SS DRIP
SS DRIP, SPAN ENTIRE
BOTTOM OF NICHES
GRANULAR
DRAINAGE BACKFILL
WRAP GRANULAR
DRAINAGE BACKFILL WITH
GEOTEXTILE FABRIC.
OVERLAP @ TOP 6" MIN.
4" HDPE PERFORATED
UNDERDRAIN SLOP @ 0.5% MIN.
MARBLE NICHE COVERS
SEALANT
MORTAR MESH IN AIR GAP
SS CONT. METAL
TERMINATION BAR
SEALED EXPANSION
JOINT (TYP.)
THRU-WALL FLUSHING
S.S. BRICK TIE SPACE EVERY
SIXTH COURSE VERTICALLY
AND 18" O.C. HORIZONTALLY
VERTICAL CELL VENT SPACE
EVERY 3RD BRICK JOINT
5 4 x 8 PRE-CAST NICHE UNIT - CLOSED END SCALE: 3/4" =1'-0" 6 4 x 8 PRE-CAST NICHE UNIT - OPEN RIGHT END
SCALE: 3/4" =1'-0" 7 4 x 8 PRE-CAST NICHE UNIT - OPEN LEFT END
SCALE: 3/4" =1'-0"
8 5 x 8 PRE-CAST NICHE UNIT - CLOSED END SCALE: 3/4" =1'-0" 9 5 x 8 PRE-CAST NICHE UNIT - OPEN RIGHT END
SCALE: 3/4" =1'-0" 10 5 x 8 PRE-CAST NICHE UNIT - OPEN LEFT END
SCALE: 3/4" =1'-0"
HORIZONTAL CELL VENT;
CENTER AT EACH CAP JOINT
HORIZONTAL CELL VENT;
EXTEND TO EDGE
VERTICAL CELL VENT, SPACE
EVERY 3RD BRICK JOINT
AIR GAP
MORTAR (3) BOTTOM
COURSES SOLID
1' -0
HORIZONTAL CELL VENT, SET FLUSH TO
BRICK FACE ON TOP OF SS DRIP; SPACE
EVERY 3RD BRICK JOINT HORIZONTALLY
11 COLUMBARIUM COLUMN NATURAL STONE LETTER PANEL DETAIL
SCALE: 1-1/2" = 1'-0"
0 1/2' 1' 2'
NICHE COVER SIDE
STAINLESS STEEL ROSETTE
1/2" CAST IN PLACE HOLE W/
3/8" Ø S.S. THREADED ROD,
NUTS AND PLASTIC SHIMS.
MARBLE NICHE COVERS W/ PRE-DRILLED DIA.
HOLES TO ACCEPT ROSETTE & BOLT - COVERS
ARE 11-1/2" WIDTH x 1'-3-3/4" HEIGHT x 34" THICK
NEOPRENE WASHER 5/8" (TYP.)
STAINLESS STEEL ROSETTE
SPANNER HEAD 3/16" x 1 1/2" S.S.
BOLT (TYP.) THROUGH 1/4" DIAM.
DRILLED HOLE.
1/2" CAST IN PLACE HOLE
PRECAST CONCRETE
NICHE
MOUNTING BRACKET
4" x 1 34" S.S. EXPANSION
BOLT, LOCK WASHER &
HEX NUT (TYP.)
PLASTIC SHIMS
NOTE:
GOVERNMENT SUPPLIED
MARBLE COVER;
CONTRACTOR INSTALLED.
ELEVATION
3/4" MARBLE
COVER
STAINLESS STEEL
ROSETTE MATTE
FINISH
STAINLESS STEEL
BRACKET
1/2" CAST IN PLACE
HOLE
ALL EXPOSED CONCRETE (NICHE FRONTS
SHALL BE GROUND OR PATCHED SMOOTH:
APPLY 2 COATS SPECIFIED HIGH BOND SEALER
ALL EDGES OF THE FRONT, BACK & CORNERS
SHALL BE SMOOTH SAWN & FINISHED WITH A
CLEAN 18" ARIS (EASED EDGE)
PRE-DRILLED WITH 38"
HOLE TO ACCEPT
BOLTS & ROSETTES
(4) TYP. VERIFY PRIOR
TO INSTALLATION.
3/8" Ø x 3" S.S. THREADED ROD, LOCK
WASHER & HEX NUTS AND PLASTIC
SHIMS, TYP.
1' -3
A
T
FA
C E
20"
3/4"
1/
2" A
T
FA
C E
3/ 4"
10-1/2" INSIDE
NICHE (FACE)
4"
11 4"
10" INSIDE
NICHE (BACK)
1'
/4
O V
E R
A
LL
(C O
V E
R
1' -2
/2
" I N
S
ID
E N
IC
H
E (B
A C
K
1' -3
" I N
S
ID
E N
IC
H
E (F
A C
E
10-1/2" INSIDE
NICHE (FACE)
11-1/4"OVERALL
(COVER)
3/4"
1/
2"
3/ 4"
1'
/4
" O V
E R
A
LL
(C O
V E
R
PRE-DRILLED WITH 38" HOLE TO
ACCEPT BOLTS AND ROSETTES (4)
TYP. VERIFY PRIOR TO
INSTALLATION
4" MARBLE NICHE COVER
ALL EDGES OF THE FRONT, BACK,
AND CORNERS SHALL BE SMOOTH
SAWN AND FINISHED WITH A CLEAN
8" ARIS (EASED EDGE)
ALL EDGES OF THE
FRONT, BACK, AND
CORNERS SHALL BE
SMOOTH SAWN AND
FINISHED WITH A
CLEAN 18" ARIS
(EASED EDGE)
4"
NOTES:
1. THE MAXIMUM DIMENSIONAL TOLERANCES FOR THE NICHE COVERS SHALL
BE AS DEFINED IN THE TECHNICAL SPECIFICATIONS.
2. GOVERNMENT SUPPLIED, CONTRACTOR INSTALLED
FRONT VIEW SIDE VIEW
11 1/4" OVERALL
(COVER)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ c_ co lu m ba riu m d et ai ls
.d w jfa hr en ka m d:
5/ 4/
1:
lo t:5
/4 /2
3:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
COLUMBARIUM DETAILS 3
LC-503
1/ 2"
A
A
3"
3 1/2"
12"
SECTION A-A SECTION B-B
BB
4" THICK STAINLESS
STREEL WELD PLATE
WITH 2" STUDS
STAINLESS STEEL STRAP
WELDED TO WELD PLATES.
DO NOT WELD JOINT.
SIZE VARIES; SEE PLAN
PLAN
ELEVATION SECTION
1 NICHE UNIT WELD PLATE
SCALE:
SECTIONFRONT
ELEVATION
STAINLESS STEEL ROSETTE
(VA STANDARD); SATIN FINISH.
PROVIDE PRODUCT LITERATURE &
SAMPLE FOR APPROVAL.
WHITE COLOR
NEOPRENE WASHER
3/16" x 1 3/4" LENGTH
STAINLESS STEEL
TAMPER-PROOF
SPANNER HEAD BOLT
1" D
IA
3/ 4"
D
IA
M
IN
STAINLESS STEEL TAMPER;
PROOF SCREW
STAINLESS STEEL
CLIP ANGLE ASSEMBLY
PLASTIC WASHER
PLASTIC LOCKWASHER
SS BOLT & HEX NUT,
1/4"-20 X 2 1/2" LONG
SS SPRING CLIP
SS SPRING CLIP
NICHE COVER MOUNTING
BRACKET, SEE 11/L-8.8
1" DIA. STAINLESS STEEL ROSETTE W/ WHITE
COLOR NEOPRENE WASHER
HEAVY DUTY STAINLESS
STEEL THREADED
SPRING-CLIP TO RECEIVE
ROSETTE BOLT
16" x 34" SLOTS
62" THICK STAMPED STAINLESS
STEEL ANGLE W/ (2) SLOTS
SIDE VIEW FRONT VIEW PLAN VIEW
1/ 2"
1/
4"
1" 1/2"
1 1/2"
1 1/4"
1/
4"
1 1/4" 1/4"
3/4"
1/ 2"
1/
2"
2 S.S. ROSETTE CONNECTION
SCALE: 1-1/2" =1'-0" 3 MARBLE NICHE COVERS
SCALE: 1-1/2" =1'-0"
4 S.S. ROSETTE
SCALE: N.T.S. 5 NICHE COVER MOUNTING BRACKET
SCALE: N.T.S.
NOTE:
ANY SEAM IN METAL TO BE FLAT SEAM - SEAMS
TO BE HORIZONTAL AND OCCUR BETWEEN
LINES OF LETTERING.
ALL LETTERING TO BE PAINTED BLACK
WITH EXCEPTION OF PROJECT TITLE
WHICH IS TO BE BLUE
2" 5"
9" M A
X
1'-0" 5"
14" M A
X
2" 5"
5" 2"
4'-0"
M
IN
3'-0"
6"
6'-0"
8'-0"
5" 5" of Veterans Affairs
U.S. Department
CENTER TO BE WHITE
SURROUNDING
BORDER TO BLUE
BACKGROUND TO BE
PAINTED WHITE
BORDER MEMBER PAINTED BLACK PAINT BORDER
MEMBER BLACK
ENAMEL
OPTIMA BOLD
STYLE 5" HIGH
LETTERING
2"X4" FRAME AND
BRACES IN SAME
PLANE
METAL FACE
WHITE ENAMEL
2"X4" FRAME
AND BRACE IN
BACK
METAL FACE
STRETCH METAL FACE
TIGHT, TURN OVER FRAME
AND SECURE WITH FLAT
HEAD DEFORMED NAILS.
LETTERING TO BE OPTIMA
BOLD STYLE 1 1/2" HIGH TO
BE CENTERED HORIZONTAL
4"X4" POSTS
PAINTED WHITE
ELEVATION SECTION
ON CENTERLINE
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
THIS SPACE FOR
CONTRACTOR'S NAME ONE
OR TWO LINES AS REQUIRED
DESIGNED AND SUPERVISED BY:
DEPARTMENT OF VETERANS
AFFAIRS WASHINGTON D.C.
GENERAL CONTRACTOR
TEMPORARY CONSTRUCTION SIGNS TO
BE FIELD LOCATED. VERIFY LOCATION
WITH SOR/COR.
SP24.1
2" 4"
3'-0" V
A R
IE
S
3'-0"
4'-0"
2" 1 3/4"
2"
BLUE
BLUE OUTLINE WITH
WHITE INTERIOR
JOINT
BRACING
4"X4" POST
FIN. GRADE
BRACING SEE
CONSTRUCTION SIGN
DETAIL THIS SHEET
RED RED
WHITE
BLUE
WOOD STRIPS
THE LIFE YOU SAVE MAY BE YOUR OWN
SEC
2-1/4"
FR
O
S T
D E
P
TH
2' -0
6" 6"
2" 8"
6-1/2" 2"
1-1/2"
7"
NOTES:
1.) "SEC" LETTERS; 1-1/2" HT., 3/15"
DEPTH, 3/16" STEMS AND BARS;
TEXT FOR SECTION ID
NUMBERSENGRAVED 2" HT., 3/16"
DEPTH, 3/8" STEMS AND BARS.
2.) SHALL BE INSTALLED TO FROST
DEPTH.
CORNERS AND EDGES INCLUDING 2"
BELOW GROUND LEVEL ROUNDED
TO 3/8" RADIUS (TYP.)
FINISHED GRADE
6 PROJECT CONSTRUCTION SIGN
SCALE: 7 PROJECT SAFETY SIGN
SCALE: 8 GRANITE SECTION MARKER
SCALE:
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
WITHOUT A LOST TIME ACCIDENT
AutoCAD SHX Text 0 0 0
AutoCAD SHX Text
DAYS
AutoCAD SHX Text
HAS WORKED
AutoCAD SHX Text
THIS PROJECT
AutoCAD SHX Text
ON SAFETY
AutoCAD SHX Text
ZERO
Department of Veterans Affairs
CO
CO
CO
CO
CO
CO
CO
CO
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ l_ la nd sc ap e pl an .d w jfa hr en ka m d:
5/
4/
0:
lo t:5 /4
/2
3:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
KEY MAP
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
PLANTING PLAN
LP-101
LEGEND
PROPERTY BOUNDARY
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
MINOR CONTOUR
MAJOR CONTOUR
SPADE EDGE
NEW SOD
NEW MULCH
1 PLANTING PLAN
SCALE: 1" = 30'
N 0 30' 60'
2 COLUMBARIUM PLANTING ENLARGEMENT
SCALE: 1" = 5'
N 0 10' 20'
BGG
BGG
BGG
BGG
LSS
IVH
IVH
SRI
SRI
BCW
LSS
LSS
LSS
PLANT SCHEDULE
TREES
Qty. Key Common & Botanical Names Size Cont. Remarks
4 ARO Red Maple, 'October Glory' 3" cal. BB Single, straight leader
Acer rubrum 'October Glory No 'v' crotches
SHRUBS
Qty. Key Common & Botanical Names Size Cont. Remarks
16 BGG Boxwood, 'Green Gem' 5 Gal. Cont. 18" ht. min.
Buxus x 'Green Gem'
6 IVH Sweetspire, 'Henry's Garnet' 5 Gal. Cont. 18" ht. min.
Itea virginica 'Henry's Garnet'
NOTE:
1. IF THERE IS A DISCREPANCY BETWEEN THE NUMBER OF PLANTS SHOWN ON THE PLAN AND
THE NUMBER OF PLANTS SHOWN IN THE PLANT LIST, THE NUMBER OF PLANTS SHOWN ON THE
PLAN WILL TAKE PRECEDENCE.
DEFINITIONS:
BB = BALLED & BURLAPPED CONT. = CONTAINER DBH = DIAMETER AT BREAST HEIGHT
CAL = CALIPER GAL. = GALLON
PERENNIALS
31 BCW Bergenia 'Winter Glow' 1 Gal. Cont. space 18" o.c.
Berfenia cordifolia 'Winterglut'
2 SRI Lilac, 'Ivory Silk' 2" cal. BB Single, straight leader
Syringa reticulata 'Ivory Silk' No 'v' crotches
3 GTI Honeylocust 'Shademaster' 3" cal. BB Single, straight leader
Gleditsia triacanthos var. inermis 'Shademaster' No 'v' crotches
4 UMG Elm 'Triumph 3" cal. BB Single, straight leader
Ulmus 'Morton Glossy' No 'v' crotches
32 LSS Creeping Lily-turf 'Silver Dragon' 1 Gal. Cont. space 18" o.c.
Liriope spicata 'Silver Dragon'
LP-101
2 1. CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED IN-KIND
WITHIN 14 CALENDAR DAYS OF COMPLETING WORK IN THE
SPECIFIC AREA.
2. LIMITS OF DISTURBANCE ARE APPROXIMATE. ALL AREAS
DISTURBED BY THE CONTRACTOR SHALL BE RESTORED.
3. CONTRACTOR SHALL FIELD LOCATE ALL PLANTINGS, REVIEW WITH
COR/RE AND CEMETERY STAFF PRIOR TO INSTALLING PLANTS.
4. DO NOT INSTALL ANY PLANT MATERIAL UNTIL AFTER THE
IRRIGATION SYSTEM IS OPERATIONAL. REFER TO IRRIGATION
PLANS FOR ADDITIONAL INFORMATION.
5. ALL SODDED AND PLANTING AREAS WITH NO PERMANENT
IRRIGATION SHALL RECEIVE TEMPORARY IRRIGATION FOR
ESTABLISHMENT. COORDINATE WITH IRRIGATION CONTRACTOR
AS REQUIRED.
NOTES
EXISTING BURIAL SECTIONS
PROPOSED BURIAL SECTIONS
PROPOSED BURIAL SECTIONS
GTI
UMG
ARO
AutoCAD SHX Text H Y D E R O A D
M I S S I S E N E W A R O A D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v a nc a m ar io n nc c iv il\
_0 ca d fil es s he et s\
8_ l_ la nd sc ap e de ta ils
.d w jd ob ia d:
5/ 4/
:2 lo t:5
/4 /2
3:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
1700 E 38TH ST, MARION, IN 46953
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF 46
05/05/2021
No. 10910393
STATEOF
INDIANA
DI
REGSTERERO
GER A AN. DERSON
PRO
FESS IONAL ENGIN
EE
R
EXP. JULY 31, 2022
PLANTING DETAILS
LP-501
1 DECIDUOUS TREE PLANTING
SCALE: N.T.S.
NOTE:
-3" DP. SHREDDED HARDWOOD MULCH SHALL BE USED IN
ALL LANDSCAPE PLANTINGS AREAS AND UNDER TREES
ISOLATED FROM PLANTING AREAS UNLESS IDENTIFIED
OTHERWISE.
-MULTI-STEM TREES SHALL NOT RECEIVE STAKING.
THEY SHALL CONFORM TO ALL OTHER DECIDUOUS
TREE PLANTING REQUIREMENTS.
3x
ROOT
BALL
CENTER TREE IN HOLE, UPRIGHT
SINGLE STRAIGHT LEADER
TREE TIE SECURED TO STAKE. SECURE TO
TREE WITH ANTI-CHAFFING MATERIAL.
ALLOW FOR MOVEMENT OF TREE.
WRAP TREE WITH TREE WRAPPING
MATERIAL AS SPECIFIED TO 1ST BRANCH
LAWN OR PLANTING BED EDGE
(SPADE EDGE IN ALL LAWN AREAS)
6" MIN. DIA. EARTH SAUCER
(3) TREE STAKES DRIVEN A MIN. 2'
BELOW GRADE.
3" DEPTH HARDWOOD MULCH
3" HEIGHT TAMPED WATER BASIN AT
EDGE OF EARTH SAUCER
FINISHED GRADE
REMOVE BURLAP, TWINE, ROPE AND
WIRE FROM TOP HALF OF
ROOTBALL
PLANTING SOIL
MOUND MIN. 6"
UNDISTURBED OR COMPACTED SOIL
AFTER EXPOSING
TREE ROOT FLAIR,
PLANT SO ROOT
FLAIR IS AT 2"
ABOVE ADJACENT
FINISH GRADE
MIN.
6"
LAWN SURFACE
UNDISTURBED OR COMPACTED SOIL
PLANTING SOIL
LINE OF PLANTING PIT WHEN
PLANTED INDIVIDUALLY
UNDISTURBED OR COMPACTED SOIL
3" DEPTH HARDWOOD MULCH
PAVED SURFACE, IF APPLICABLE
MIN.
6"
3' MIN. TO PAVED
SURFACES
PLANTING SOIL
3" DEPTH HARDWOOD
MULCH
PAVED SURFACE,
OR LAWN
UNDISTURBED OR
COMPACTED SOIL
EDGE OF GROUNDCOVER
AREA/WALK EDGE
DISTANCE FROM EDGE
IS 12 THE SPECIFIED
O.C. SPACING
TRIANGULAR SPACE,
AT SPECIFIED O.C.
DISTANCE - EQUIDISTANT
PLANT CENTER
HARDWOOD MULCH
ROOTBALL
PLANTING SOIL
NATIVE SOIL
NORTHWEST
PREVAILING
WINDS
SOUTHEAST
PREVAILING
WINDS
TREE TIE SECURED TO
STAKE. SECURE TO TREE
WITH ANTI-CHAFFING
MATERIAL. ALLOW FOR
MOVEMENT OF TREE.
(3) TREE STAKES DRIVEN A MIN. 2'
BELOW GRADE (NW & SE)
PLAN VIEW OF TREE STAKING
NOT TO SCALE
HARDWOOD MULCH
LAWN
3 PLAN VIEW OF TREE STAKING
SCALE: N.T.S.
2 DECIDUOUS SHRUB PLANTING
SCALE: N.T.S. 4 SHRUB BED SPACING
SCALE: N.T.S.
5 EVERGREEN SHRUB PLANTING
SCALE: N.T.S.
6 SPADE EDGE
SCALE: N.T.S.
BOUNDARY BETWEEN
LAWN &PLANTING AREA AS
SHOWN ON PLAN
PREPARED SUBGRADE
6" DEEP SHOVEL CUT
LAWN
MULCH
PLANTING AREA
12"
3"DP.
TYP.
FERTILIZER PLANT TAB
1. NEITHER THE PROFESSIONAL ACTIVITIES OF THE ENGINEER, NOR THE PRESENCE OF THE
ENGINEER OR THEIR EMPLOYEES AND SUBCONSULTANTS AT THE CONSTRUCTION SITE,
SHALL RELIEVE THE CONTRACTOR AND ANY OTHER ENTITY OF THEIR OBLIGATIONS,
DUTIES AND RESPONSIBILITIES INCLUDING BUT NOT LIMITED TO, CONSTRUCTION MEANS,
METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING,
SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE CONSTRUCTION WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY
PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. THE ENGINEER AND THEIR
PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY
CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION
WITH THEIR WORK OR ANY HEALTH OR SAFETY PRECAUTIONS. THE CONTRACTOR IS
SOLELY RESPONSIBLE FOR THE JOBSITE SAFETY. THE ENGINEER AND THE ENGINEER’S
CONSULTANTS SHALL BE MADE ADDITIONAL INSUREDS UNDER THE CONTRACTOR’S
GENERAL LIABILITY INSURANCE POLICY.
2. ALL DRAWINGS AND SPECIFICATIONS ARE CONSIDERED TO BE A PART OF THE CONTRACT
DOCUMENTS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW AND
COORDINATION OF ALL DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF
CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO THE START OF CONSTRUCTION SO A CLARIFICATION CAN BE
ISSUED. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS OR ANY
CODE REQUIREMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT THEIR OWN
EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT OR STRUCTURAL
ENGINEER OF RECORD.
3. ALL DIMENSIONS AND SITE CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AT THE
JOBSITE PRIOR TO CONSTRUCTION, START OF SHOP DRAWINGS, START OF
CONSTRUCTION, AND/OR FABRICATION OF MATERIALS. IF DISCREPANCIES ARE
ENCOUNTERED, OR CONDITIONS DEVELOP THAT ARE NOT COVERED BY THE CONTRACT
DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION.
4. CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR
OF ADJACENT EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED AS A RESULT
OF NEW WORK.
5. STRUCTURAL DRAWINGS INCLUDE DESIGN REQUIREMENTS AND DIMENSIONS FOR
STRUCTURAL INTEGRITY BUT DO NOT SHOW ALL DETAIL DIMENSIONS TO FIT INTRICATE
ARCHITECTURAL DETAILS. CONTRACTOR SHALL SO CONSTRUCT THE WORK SO IT WILL
CONFORM TO THE CLEARANCES REQUIRED BY ARCHITECTURAL DESIGN.
6. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO BE
CONSTRUCTION STANDARDS. IF CLARIFICATION IS REQUIRED, THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
7. DO NOT SCALE DRAWINGS. PRINTED DIMENSIONS HAVE PRECEDENCE OVER SCALED
DRAWINGS AND LARGE-SCALE OVER SMALL-SCALE DRAWINGS. CONTRACTOR TO
DETERMINE FINAL DIMENSION WITH ARCHITECT.
8. TYPICAL DETAILS SHALL APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE
THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. WHERE NO DETAILS ARE
GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK.
9. THE CONTRACT DOCUMENTS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE
AND SAFETY OF WORKMEN DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE,
BUT NOT BE LIMITED TO, BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION
EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR STRUCTURAL
ENGINEER SHALL NOT INCLUDE INSPECTION OR APPROVAL OF THE ABOVE ITEMS AND
DOES NOT IN ANY WAY RELIEVE THE CONTRACTOR OF THEIR RESPONSIBILITIES FOR THE
ABOVE.
10. SEE ARCHITECTURAL DRAWINGS FOR DETAILS, CONDITIONS, SLEEVES, ITEMS TO BE
EMBEDDED OR ATTACHED TO STRUCTURAL ELEMENTS, ETC., NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
11. NO HOLES, NOTCHES, BLOCKOUTS, ETC. ARE ALLOWED IN STRUCTURAL ELEMENTS
UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE
STRUCTURAL ENGINEER.
12. BEFORE SUBMITTING A PROPOSAL FOR THIS WORK, EACH BIDDER SHALL VISIT THE
PREMISES AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS,
TEMPORARY CONSTRUCTION REQUIRED, QUANTITIES AND TYPE OF EQUIPMENT, ETC. THE
BID SHALL INCLUDE ALL SUMS REQUIRED TO DO THE WORK WITHIN THE EXISTING
CONDITIONS.
13. SHOP DRAWINGS SHALL BE REVIEWED AND COORDINATED PRIOR TO SUBMITTING TO THE
ARCHITECT. EACH SHOP DRAWING SUBMITTED SHALL BE STAMPED INDICATING REVIEW
BY THE GENERAL CONTRACTOR AND REVIEW BY THE ARCHITECT SHALL NOT BEGIN UNTIL
THIS IS COMPLETE. WORK SHALL NOT BEGIN WITHOUT REVIEW BY THE
ARCHITECT/STRUCTURAL ENGINEER.
14. SHOP DRAWINGS SHALL BE REVIEWED BY THE ARCHITECT/STRUCTURAL ENGINEER FOR
GENERAL CONFORMANCE WITH DESIGN CONCEPT ONLY. NOTATIONS MADE BY THE
ARCHITECT/STRUCTURAL ENGINEER ON THE SHOP DRAWINGS DO NOT RELIEVE THE
CONTRACTOR FROM COMPLYING WITH THE REQUIREMENTS OF THE DRAWINGS AND
SPECIFICATIONS.
GENERAL
1. STRUCTURE HAS BEEN DESIGNED TO COMPLY WITH:
IBC 2018
ASCE/SEI 7-16
ACI 318-14
2. RISK CATEGORY I
3. SEISMIC:
SEISMIC DESIGN CATEGORY B
IMPORTANCE FACTOR 1.0
SOIL CLASSIFICATION PER
GEOTECHNICAL REPORT D
SS 0.131g S1 0.071g Sds 0.140g Sd1 0.114g
4. WIND:
BASIC WIND SPEED 103 MPH
EXPOSURE CLASS B
MWFRS DESIGN PRESSURE 20 PSF.
5. SNOW:
GROUND SNOW 20 PSF
SNOW EXPOSURE FACTOR 0.9
THERMAL FACTOR 1.2
IMPORTANCE FACTOR 0.8
DESIGN SNOW 21 PSF
DESIGN CRITERIA AND LOADS
CAST-IN-PLACE CONCRETE
1. CONCRETE STRENGTHS SHALL CONFORM TO:
2. DRYPACK SHALL BE 1:3-1/2 PORTLAND CEMENT TO SAND WITH A MINIMUM 28-DAY
STRENGTH OF 7000 PSI.
INTENDED USE
28-DAY
STRENGTH (PSI)
MAX W/C
RATIO
A/E SLUMP
UNLESS NOTED OTHERWISE 4000 0.45 5-8% 1"-4"
1. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT DATED
AUGUST 28, 2020 BY TERRACON. REPORT IS ON FILE WITH THE ARCHITECT.
2. SOIL PROPERTIES PER THE GEOTECHNICAL REPORT:
ALLOWABLE NET SOIL BEARING PRESSURE:
FOOTINGS 2500 PSF
ANTICIPATED DEPTH TO ALLOWABLE
SOIL BEARING 3'-0" BELOW EXISTING GRADE
FROST DEPTH 3'-0"
3. ALL EXCAVATIONS SHALL BE PROPERLY AND SAFELY BACKFILLED.
4. SEE 5/SS100 FOR COLUMBARIUM PAD SITE PREPARATION DETAIL.
EARTHWORK
REINFORCING STEEL
1. CONCRETE REINFORCING STEEL SHALL BE HIGH STRENGTH NEW BILLET STEEL
CONFORMING TO THE FOLLOWING STANDARDS:
DEFORMED BARS ASTM A615, GR60 Fy = 60 KSI
2. MINIMUM CONCRETE COVER SHALL BE PROVIDED AS FOLLOWS TO THE
OUTERMOST REINFORCING BARS:
CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND 3"
EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
#6 BARS OR LARGER 2"
#5 BARS OR SMALLER 1 1/2"
3. BAR SPLICES SHALL BE PROVIDED WHERE INDICATED ON THE DRAWINGS. ALL
SPLICES SHALL BE CLASS 'B' AS DEFINED IN ACI 318. IF SPLICE LENGTH IS NOT
GIVEN ON THE DRAWINGS, PROVIDE LAP LENGTH (IN INCHES) AS FOLLOWS:
LAP LENGTHS ASSUME CLEAR SPACING BETWEEN BARS OF 2 BAR DIAMETERS, AND
A MINIMUM COVER OF 1 BAR DIAMETER. FOR DEVELOPMENT LENGTHS, DIVIDE BY
1.3. TOP BARS ARE DEFINED AS HORIZONTAL BARS WITH MORE THAN 1'-0" OF
FRESH CONCRETE BELOW.
BAR
SIZE
#3
OTHER
TOP
4000 PSI CONCRETE
#4 25 33
#5 31 41
#6 37 49
POST-INSTALLED ANCHORS
1. ANCHORS SERVING AS THE BASIS OF DESIGN ARE SHOWN ON THE DRAWINGS.
ACCEPTABLE ALTERNATIVE ANCHORS MAY BE SUPPLIED PROVIDED THE QUANTITY
AND CONFIGURATION MATCH THE CAPACITY OF THE DESIGN ANCHOR QUANTITY
AND CONFIGURATION. ANY ALTERNATES ARE TO BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW. INSTALL IN ACCORDANCE WITH
MANUFACTURER’S WRITTEN INSTRUCTIONS. BELOW SUMMARIZES EACH ANCHOR
TYPE USED ON THE PROJECT.
2. ADHESIVE ANCHORS: SHALL CONSIST OF DEFORMED REINFORCING BARS OR
ASTM A193 GRADE B7 RODS, HEAVY DUTY NUTS AND WASHERS AND A TWO
COMPONENT STRUCTURAL ADHESIVE. WHERE ANCHORING INTO HOLLOW
MASONRY, A SCREEN TUBE SHALL BE PROVIDED.
ANCHORED
INTO
BASIS OF DESIGN ACCEPTABLE ALTERNATES
CONCRETE
DEWALT AC 200+
SIMPSON SET-3G
HILTI HIT-HY 200
STRUCTURAL ABBREVIATION KEY
Ø -3"
ARCH
B.O.
CLR
CL
CMU
CONT
DIA
EL
EQ
(E)
EXP
EXT
f 'c Fy
HORIZ
LLH
LLV
LSH
LSV
MAX
MIN
N
NTS
OC
PCF
PL
PLF
PSF
PSI
REINF
REQD
SIM
SP
SPEC
T.O.
TYP
UNO
VERT
VIF
VWA
W/
NUMBER OR POUNDS
AT
DEGREE
DIAMETER
SLAB DEPRESSION
ARCHITECT, -URE, -URAL
BOTTOM OF
CLEAR
CENTERLINE
CONCRETE MASONRY UNIT
CONTINUOUS
DIAMETER
ELEVATION
EQUAL
EXISTING
EXPANSION
EXTERIOR
CONCRETE COMPRESSIVE STRENGTH
YIELD STRESS
HORIZONTAL
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONG SIDE HORIZONTAL
LONG SIDE VERTICAL
MAXIMUM
MINIMUM
NORTH
NOT TO SCALE
ON CENTER
POUNDS PER CUBIC FOOT
PLATE
POUNDS PER LINEAR FOOT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
REINFORCING, -MENT, -ED
REQUIRED
SIMILAR
SPACE(S)
SPECIFICATION(S)
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
VERIFY IN FIELD
VERIFY WITH ARCHITECTURAL DRAWINGS
WITH
ABBR: DESCRIPTION:
STRUCTURAL SYMBOL LIST
NOT ALL SYMBOLS MAY APPLY
SYMBOL: DESCRIPTION:
ELEVATION
ABOVE ELEVATION +0' - 0"
STEP IN FOOTING
(+16' - 3")
S
FOUNDATION PREPARATION
VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.
PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
X
X
X
C O
N T
IN
U
O U
S
P E
R
IO
D
IC
REFERENCED
STANDARD
IBC
REFERENCE
VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X
PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT THE SITE HAS BEEN PROPERLY PREPARED.
X
STRUCTURAL COMPONENT TESTING AND INSPECTION
1. THE FOLLOWING TESTING AND INSPECTION OF STRUCTURAL COMPONENTS IS REQUIRED AS DETAILED IN CHAPTER 17 OF THE 2018 INTERNATIONAL BUILDING CODE (IBC) AND PROJECT
SPECIFICATIONS.
2. SEE ARCHITECTURAL, CIVIL SPECIFICATIONS FOR TESTING AND INSPECTION REQUIREMENTS OF NON-STRUCTURAL COMPONENTS.
3. WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5.1 OF CHAPTER 17 OF THE 2018 INTERNATIONAL BUILDING CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE BELOW. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD.
DUTIES OF THE SPECIAL INSPECTION AGENCY (IBC CHAPTER 17):
A. SUBMIT A PROPOSED TESTING AND INSPECTION PROGRAM TO THE OWNER, THE ARCHITECT AND THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL AT LEAST TWO WEEKS PRIOR TO COMMENCEMENT OF WORK. THE TABLE BELOW SHALL SERVE AS A GUIDELINE FOR THE SCOPE OF THE TESTING AND INSPECTION PROGRAM.
B. PERFORM ALL TESTING AND INSPECTION REQUIRED PER APPROVED TESTING AND INSPECTION PROGRAM.
C. FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE OWNER, THE ARCHITECT, THE ENGINEER OF RECORD AND THE GENERAL CONTRACTOR. THE REPORTS SHALL BE COMPLETED
AND FURNISHED WITHIN 48 HOURS OF INSPECTED WORK.
D. SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTION AGENCY'S KNOWLEDGE, IN CONFORMANCE
WITH THE APPROVED PLANS AND SPECIFICATIONS.
CONCRETE AND CONCRETE PLACEMENT
REVIEW OF PROPOSED MIX DESIGN AND SUPPORTING TEST RESULTS.
X
XINSPECTION OF FABRICATORS AND DURING FABRICATION.
INSPECTION OF REINFORCING STEEL, AND PLACEMENT.
X
VERIFYING USE OF REQUIRED DESIGN MIX. X ACI 318: CH. 19, 26.4.3, 26.4.4
PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE.
ASTM C172, ASTM C31,
ACI 318: 26.4, 26.12
X
INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. ACI 318: 26.5
INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
X
ACI 318: 26.5.3 - 26.5.5X
1904.1, 1904.2, 1908.2, 1908.3
1908.10
1908.6, 1908.7, 1908.8
1908.9
1704.2
1908.4ACI 318: Ch. 20, 25.2, 25.3,
26.6.1 - 26.6.3
XINSPECT ANCHORS CAST IN CONCRETE.
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. X ACI 318: 26.11.1.2(b)
ACI 318: 17.8.2
X ACI 318: 17.8.2.4
INSPECTION ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS.
B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN ROW ABOVE. X ACI 318: 17.8.2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
BID DOCUMENTS
Project Director
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
CONSULTANT
Services
KEY MAP
MARIO ARREDONDO Dwg of
C R e v it L o c a l F ile s \S
.1
M a ri o n N a ti o n a l C e m e te ry
C E
N T
R A
L M e h u lk u m a r.
V .N a k ra n i.
rv t
/2
/2
:3
:4
P
M
SS000
GENERAL NOTES
1700 E 38TH ST, MARION, IN 46953
817CM3022
MAY 05, 2021 ERIREI PRIPAN
15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
Revisions: Date: 4632
20' - 1 1/2"
EL ( 839.38 )
T.O. WALL
20' - 1 1/2"
WEST FACE OF NEW WEST SET OF
COLUMBARIUM TO ALIGN WITH WEST
FACE OF EXISTING COLUMBARIUM
(E) COLUMBARIUM 4 (E) COLUMBARIUM 3
1' - 6 1/2" 4 1/2"
20' - 1 1/2"
4 1/2" 1' - 6 1/2"
20' - 1 1/2"
EAST FACE OF NEW EAST SET OF
COLUMBARIUM TO ALIGN WITH EAST
FACE OF EXISTING COLUMBARIUM
SS100
TYP
E Q
/4
E Q
E Q
/4
E Q
E Q
/4
E Q
E Q
/4
E Q
EL ( 846.48 )
T.O. PIER
EL ( 839.30 )
T.O. WALL
EL ( 845.03 )
T.O. PIER
EL ( 846.48 )
T.O. PIER
EL ( 845.03 )
T.O. PIER
EL ( 839.55 )
T.O. WALL
EL ( 845.28 )
T.O. PIER
EL ( 845.28 )
T.O. PIER
EL ( 839.47 )
T.O. WALL
EL ( 846.57 )
T.O. PIER
EL ( 846.57 )
T.O. PIER
4 1/2" 1' - 6 1/2"
4 3/4" 1' - 6 1/2"
4 3/4" 1' - 6 1/2"
4 1/2" 1' - 6 1/2" 1' - 6 1/2"
4 1/2"
5 HIGH NICHE
4 HIGH NICHE
4 HIGH NICHE
5 HIGH NICHE
SS100
TYP
NOTE:
1. VERIFY DIMENSIONAL LAYOUT AND ELEVATIONS WITH LC SHEETS.
4 1/2" 1' - 6 1/2"
3' - 2 3/4"
/4
4' - 0"
(3) #6 CONT
#4 U-BARS @ 12" OC
(4) #6 CONT TOP
(2) #6 CONT SIDE
BARS, EACH SIDE
(4) #6 CONT BOTTOM
EL ( SEE PLAN )
T.O. WALL
T.O. LEDGE
#4 TIES @ 48" OC
EL (SEE PLAN)
T.O. PIER
DOWELS WITH STD 90 DEG
HOOK. MATCH VERTICAL
BAR SIZE AND SPACING
SEE 2/SS100 FOR FOOTING
INFORMATION
VERTICAL REINFORCEMENT
SEE PIER DETAIL
TIE REINFORCEMENT
SEE PIER DETAIL
SS100
EL ( SEE PLAN )
T.O. WALL
SEE PLAN
SEE PLAN
T.O. LEDGE
SS100
S E
E P
L A
N
SEE PLAN
(8) #6 VERT
#4 TIES AND CROSS
TIES @ 12" OC
N O
T E
5' - 0" 5' - 0"
COLUMBARIUM
FOUNDATION
FINISH GRADE
CONTRACTOR TO
DETERMINE SLOPE.
NOTES:
1. COORDINATE LENGTH OF COLUMBARIUM EXCAVATION WITH CIVIL AND LANDSCAPE DRAWINGS.
2. GEOTECHNICAL REPORT INDICATES APPROXIMATELY 5'-0" OF OF FAT CLAY WITH SAND IN AREA OF
COLUMBARIUM. CONTRACTOR TO REMOVE MINIMUM OF 2'-0" OF FAT CLAY BELOW BOTTOM OF
FOOTING.
3. AFTER EXCAVATING TO DEPTH SPECIFIED ABOVE, IF THE EXPOSED SUBGRADE IS COHESIVE SOIL, IT SHALL BE PROOF ROLLED WITH A FULLY LOADED DUMP TRUCK OR COMPARABLE PNEUMATIC TIRED VEHICLE. IF THE SUBGRADE IS GRANULAR SOILS, THEN THE SUBGRADE NEEDS TO BE COMPACTED
WITH A VIBRATORY ROLLER.
4. OVER-EXCAVATE ANY CONFIRMED WEAK YIELDING ZONES, BOTH VERTICALLY AND HORIZONTALLY, TO EXPOSE COMPETENT SOIL.
5. PLACE ACCEPTABLE STRUCTURAL FILL UNDER THE FOOTINGS IN LOOSE LIFTS OF ABOUT 8 INCHES TO ACHIEVE REQUIRED ELEVATIONS. EACH LIFT SHALL BE MOISTURE CONDITIONED BETWEEN -2 AND +2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 95%
OF THE MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557.
6. PLACE ACCEPTABLE GENERAL FILL IN AREAS NOT COVERED IN NOTE 5 IN LOOSE LIFTS OF ABOUT 8
INCHES TO ACHIEVE REQUIRED ELEVATIONS. EACH LIFT SHALL BE MOISTURE CONDITIONED
BETWEEN -2 AND +2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 90% OF THE MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557.
7. SEE GEOTECHNICAL REPORT FOR USCS CLASSIFICATION FOR ACCEPTABLE STRUCTURAL FILL
MATERIAL AND GENERAL FILL MATERIAL. ALL MATERIAL TO BE APPROVED AND COMPACTION
OBSERVED BY GEOTECHNICAL ENGINEER TO VERIFY THE ADEQUACY OF THE COMPACTION EFFORT.
FOR NEW FOUNDATIONS ADJACENT TO
EXISTING TO REMAIN, CONTRACTOR TO
DESIGN AND INSTALL SHORING TO NOT
UNDERMINE EXISTING.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
BID DOCUMENTS
Project Director
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
CONSULTANT
Services
KEY MAP
MARIO ARREDONDO Dwg of
C R e v it L o c a l F ile s \S
.1
M a ri o n N a ti o n a l C e m e te ry
C E
N T
R A
L M e h u lk u m a r.
V .N a k ra n i.
rv t
/2
/2
:3
:4
P
M
SS100
COLUMBARIUM FOUNDATION PLAN
1700 E 38TH ST, MARION, IN 46953
817CM3022
MAY 05, 2021 ERIREI PRIPAN
15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
N O R
HT
1/4" = 1'-0"
COLUMBARIUM FOUNDATION PLAN
1 3/4" = 1'-0"
COLUMBARIUM SECTION
3/4" = 1'-0"
COLUMBARIUM SECTION
3 1" = 1'-0"
PIER DETAIL
4 1/4" = 1'-0"
COLUMBARIUM PAD SITE PREPARATION
5 SCHEMATIC
Revisions: Date: 4633
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
AND SEE AS-BUILT
DRAWINGS
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
AND SEE AS-BUILT
DRAWINGS
C
MATCHLINEMATCHLINE
4"4"
3"
4" 2"
3" 3"
3"
4"
4"
4"
2"
2"21
2"
2"
2"
2"
2"
2" 11 2"
2"11
2"
2"
2"
2" 11 2"
2"
2"
2" 11 2"
2"11
2"
2" 11 2"
2"11 2" 11
2"
2"11 2" 11
2"
2"11 2"
2"
2"
2"
2"
2" 11
2"
2"
2" 2"
2"
2"
2"11
2"
27 61.2
2"
28 61.2
2"
29 45.9
2"29
30 45.9
2"30
31 45.9
2"
32 7.10 1"
33 45.9
2"
34 61.2
2"
3530.6 1"
3630.6 1"
3745.9
2"
3845.9
2"
3945.9
2"
4061.2
2"
4161.2
2"
4245.9
2"
4361.2
2"
4461.2
2"
SEPARATE CONDUIT
2"
CONTRACTOR
RESPONSIBLE FOR
R.F. SITE SURVEY
FOR PROPER
COMMUNICATION
TO CENTRAL -
PULL POWER WIRE
FROM
EXISTING/NEW
PUMP STATION AS
PART OF BASE BID
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird 1804-SAM-PRS w/ 5 Series MPR Nozzles 46 Turf Spray 4" Pop-Up Sprinkler with Co-Molded Wiper Seal.
1/2" NPT Female Threaded Inlet With Seal-A-Matic Check Valve.
Rain Bird 8005-SS-14 173 Turf Rotor, 5.0" Pop-Up, Stainless Steel Riser, Standard Nozzle.
With Seal-A-Matic Check Valve, Adjustable 50-330 arc, and 360 Non-Reversing Full-Circle. 1" NPT Female Threaded Inlet.
Note: For Arc Reference See Irrigation Coverage Sheet IR-102/IR-103.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird 150-EFB-CP-PRS-D 41 1-1/2" Brass Remote Control Valve w/ Tucor RKLD-050 Decoder
Rain Bird 100-EFB-CP-PRS-D 3 1 Brass Remote Control Valve w/ Tucor RKLD-050 Decoder
Rain Bird 44-LRC 21 1" Brass Quick-Coupling Valve, with Corrosion-Resistant Stainless Steel Spring, Locking Thermoplastic Rubber Cover, and 2-Piece Body.
RT/RW CLOW Isolation Valve - Line Sized 22
Tukor RKD+ w/ RKLD-050 Decoders 2 Stainless Steel Nema 4 Pedestal Field Satellite to Have Rain Bird Sensor w/ Bypass Located Out of Irrigation Coverage
Bermad C30 2" Air/Vacuum Relief Valve 2
Watertronics Pump Station 1
Tucor SP-100 Surge Protector 8 W/ Paige Wire 36" Ground Plate and Assembly w/ Ground Enhancement Materials - As Per Manufacture's Recommendations.
Paige 270RCX Re-Enterable Connector 3 W/ Paige Wire 36" Ground Plate and Assembly w/ Ground Enhancement Materials - As Per Manufacture's Recommendations.
Irrigation Lateral Line: PVC Class 200 SDR 21 (1-1/2" - 2-1/2") 7,640 l.f.
- All "Dashed" Lateral Lines to be Hand Trenched
Irrigation Mainline: PVC Class 200 SDR 21 (3" - 6") 4,184 l.f.
Pipe Sleeve: PVC C900 DR 18 Class 235 73.9 l.f.
(Two Sizes Larger Than Pipe Carried)
120vac Power Wire - #8 Pair w/ Grd (Black, White, Green) To Have Pull Boxes (w/ 12" Wire Coiled) Located Every 100' Lid Marked As Per NC Requirements
#12 Paige Maxi Comm Two-Wire Cable
Note: All Quantities Are For Reference Only. Contractor Responsible For Actual Bid Counts.
A
P
Valve Number
Valve Size
Valve Flow (Apprx GPM)
Valve Callout
C
LEGEND
B-8B-8
2"
2" 31
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h e c d s e r v e r p c n e t s h a r e c o l e s p r o j e c t s m a r i o n n a t i o n a l c e m e t e r y m a r i o n p h a s e m a r i o n n c i r r i g a t i o n d w e d i t n n a v e d l o t
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
STRUCTURAL / MEP:
IMEG
2882 106TH STREET
DES MOINES, IA 50322
515.334.4308
TODD BARRETT, PE
MARIO ARREDONDO
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15848
MARION NATIONAL CEMETERY
GRAVESITE EXPANSION
817CM3022
MAY 05, 2021
MARION, INDIANA
BID DOCUMENTS
BID DOCUMENTS
Date:
IRRIGATION:
EC DESIGN GROUP, LTD
400 5TH STREET
WEST DES MOINES, IA 50265
515.225.6365
LISA RUDISH, ASIC
GEOTECHNICAL:
TERRACON
7770 WEST NEW YORK ST.
INDIANAPOLIS, IN 46214
317.273.1690
GURKAN OZGURGEL, PE
COST ESTIMATING:
CPMI
1001 GRAND AVE. SUITE 201
WEST DES MOINES, IA 50265
515.244.1166
BRYAN BERTRAND
OF --
SITE IRRIGATION PLAN
1 7
IR-101
0 feet20
1" = 10'
10 30
0 feet60
1" = 30'
30 90
B-3
B-4
B-5
B-6
B-7
B-8
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
MATCHLINEMATCHLINE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird 1804-SAM-PRS w/ 5 Series MPR Nozzles 46 Turf Spray 4" Pop-Up Sprinkler with Co-Molded Wiper Seal.
1/2" NPT Female Threaded Inlet With Seal-A-Matic Check Valve.
Rain Bird 8005-SS-14 173 Turf Rotor, 5.0" Pop-Up, Stainless Steel Riser, Standard Nozzle.
With Seal-A-Matic Check Valve, Adjustable 50-330 arc, and 360 Non-Reversing Full-Circle. 1" NPT Female Threaded Inlet.
Note: For Arc Reference See Irrigation Coverage Sheet IR-102/IR-103.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird 150-EFB-CP-PRS-D 41 1-1/2" Brass Remote Control Valve w/ Tucor RKLD-050 Decoder
Rain Bird 100-EFB-CP-PRS-D 3 1 Brass Remote Control Valve w/ Tucor RKLD-050 Decoder
Rain Bird 44-LRC 21 1" Brass Quick-Coupling Valve, with Corrosion-Resistant Stainless Steel Spring, Locking Thermoplastic Rubber Cover, and 2-Piece Body.
RT/RW CLOW Isolation Valve - Line Sized 22
Tukor RKD+ w/ RKLD-050 Decoders 2 Stainless Steel Nema 4…