S02_Attachment 06 (SCLSA)_36C24125Q0377.pdf
PDF 6 MB Posted
- Attached to
- EHRM Installation of NextGen Wi-Fi Upgrade
- Solicitation number
- 36C24125Q0377
About this file
This document is a Statement of Conditions and Life Safety Assessment (SCLSA) for the Providence VA Medical Center located at 830 Chalkstone Avenue in Providence, Rhode Island. The 14-page document is dated August 6, 2021, and is part of the "EHRM Installation of NextGen Wi-Fi Upgrade" construction project for the VA Health Care System.
The document provides a comprehensive overview of fire safety, building codes, and life safety requirements for the facility. Key details include adherence to the 2018 edition of NFPA 101 Life Safety Code, detailed specifications for fire sprinkler systems, fire alarm systems, and occupancy classifications. The building is fully sprinklered and classified with mixed occupancy types, including health care, business, and special purpose industrial spaces. The assessment outlines specific requirements for fire barriers, smoke zones, corridor access, exit signage, and other critical safety components across the facility's nine floors, with approved site-specific equivalencies for certain fire safety measures.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 06
SCLSA
14 pages
6 August 2021
Providence, Rhode Island VA Health Care System (650)
“EHRM Installation of NextGen Wi-Fi Upgrade”
Construction
LOCATION MAP
TRUE
NORTH
DRAWING TITLEDWG
NO.
INDEX OF DRAWINGS
DRAWING TITLEDWG
NO.
STATEMENT OF CONDITIONS
& LIFE SAFETY ASSESSMENT
FINAL SUBMITTAL
PROVIDENCE VA MEDICAL CENTER
830 CHALKSTONE AVENUE
PROVIDENCE, RI
AREA MAP
TRUE
NORTH
MAIN CAMPUS
COVER SHEET - G001
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
FP&C Project Number 3252.00
G001
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
WALL:
DUCTS:
PENETRATIONS:
DOORS*:
WALL:
DUCTS:
DOORS:
WALL:
DUCTS:
PENETRATIONS:
DOORS:
SUITE DESIGNATION
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF
4 OR MORE STORIES.
2-HOUR FIRE AND SMOKE ZONE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION
OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
1-HOUR FIRE BARRIER
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES PER NFPA 101 8.6.5(2) AND STAIRWELLS 3 STORIES OR LESS. PER NFPA 101 19.3.2.1
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS
OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND
THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE
ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED
TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
(COLOR #5)
(COLOR #4)
(COLOR #1)
(COLOR #2)
(COLOR #3)
NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2019 EDITION OF NFPA 80 AND NFPA 105. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,
SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)
(COLOR #30)
NON-RATED SMOKE ZONE PARTITION
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER
ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY
THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE
MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.
WALL:
DUCTS:
PENETRATIONS:
DOORS:
HEALTH CARE OCCUPANCY CORRIDORS
THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE.
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO
BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO MAX AREA
TESTED.
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES (NFPA 101
7.1.3.2.1)(3).
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80
6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED
TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM AREA TESTED WINDOW (NFPA 80 TABLE 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR
LESS. (NFPA101 7.1.3.2.1)(1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE
PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.
3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105
5.2.5.1)
WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
(COLOR #30)
(COLOR #2)
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24
SUPERVISION - NO SMOKE DETECTION REQUIRED.
(COLOR #3)
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE
DETECTION PROVIDED.
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
(COLOR #230)
(COLOR #4)
NON-FIRE RATED SMOKE BARRIER
SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE
OF RESTRICTING THE MOVEMENT OF SMOKE.
WALL: EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE
BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH NON-FIRE RATED MATERIALS TO PREVENT THE
TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.
DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON LABELED FRAME (NFPA 101 8.5)
2. NON FIRE RATED DOOR (NFPA 101 8.5)
3. NO GRILLS OR LOUVERS ARE PERMITTED (NFPA 101 8.5.1)
4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.43)
6. MAXIMUM ¾” UNDERCUT (NFPA 101 8.5.4.1)
7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)
8. SWING IN ANY DIRECTION (NFPA 8.5)
9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 8.5)
10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)
WALL:
DUCTS:
DOORS:
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT
HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING
AND SHALL EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED
FIRESTOP MATERIALS IS NOT REQUIRED.
EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 8.4.2)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 105 A.6.3.1) 1 3 4" THICK.
3. POSITIVE LATCHING IS REQUIRED PER (NFPA 105 6.3.4)
4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
5. MAXIMUM 1/8" GAP (NFPA 105 6.3.3)
6. MAXIMUM 3 4" UNDERCUT (NFPA 80 4.8.4.1)
7. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.4)
8. SWING IN ANY DIRECTION
9. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA
105 5.2.5.1)
PENETRATIONS:
(COLOR #30)
EXIT STAIRWELL/PASSAGEWAY
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
FP&C Project Number 3252.00
SOC X-1
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
FIRE/SMOKE BARRIER
DESCRIPTION
APPLICABLE CODES AND STANDARDS: FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13 - 3.3.4.16).
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 225 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15
GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13 - TABLE 19.3.3.1.2).
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT. DENSITY.
6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13 - 10.2.5.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS IN SMALL ROOMS (800 SQ. FT. MAXIMUM) SHALL NOT
EXCEED 9' FROM ANY SINGLE WALL (NFPA 13 - 10.2.5.2.3).
7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13 - 12.1.10.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE 2019 EDITION ON NFPA 13. SPRINKLERS NOT REQUIRED UNDER
NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13 - 9.5.5.3.1).
8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13 - 10.2.6.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13 - 10.2.6.1.2).
9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA 13 - 9.5.6.1).
10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE PER NFPA 13 - 9.2.5(2).
11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.1.2 AND FIGURE 10.2.7.1.2(a).
12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.2.2 AND FIGURE 10.2.7.2.2.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND TO DEFINE THE END OF PUBLIC EXIT
CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE MAY DIRECT OCCUPANTS INTO A SUITE TO REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B) D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION - 10,000 SQ. FT. (NFPA
101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.3)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED IN TABLE A.7.6
OF NFPA 101.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO THE REQUIREMENTS OF NFPA 72, NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2018 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF NFPA
72 - 2019 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72 - 2019
EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72 - 2019 EDITION.
6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA (NFPA 72 - 17.7.3.2.3.1)
7. SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS MAY
BE SPACED AT MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE (NFPA 72 - 17.7.5.6.1) SMOKE DETECTORS NOT CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 72- 17.7.5.6.
8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF CEILING HEIGHT SHALL HAVE REDUCED SMOKE DETECTOR SPACING
COVERAGE (NFPA 72 - 17.7.3.2.4.2).
9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE
DETECTOR (NFPA 72- 17.7.3.2.1).
10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).
1. THE ORIGINAL BUILDING WAS DESIGNED TO THE 1943 EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST EDITIONS OF NATIONALLY
RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
B. NFPA 13 - SPRINKLER SYSTEMS, 2019 EDITION
C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION
D. NFPA 20 - FIRE PUMPS, 2019 EDITION
E. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2020 EDITION
F. NFPA 70 - NATIONAL ELECTRIC CODE, 2020 EDITION
G. NFPA 72 - NATIONAL FIRE ALARM CODE, 2019 EDITION
H. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION
I. NFPA 80 - FIRE DOORS, 2019 EDITION
J. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION
K. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION
L. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION
M. NFPA 105 - SMOKE DOORS, 2019 EDITION
N. NFPA 110 - EMERGENCY POWER SYSTEMS, 2019 EDITION
O. NFPA 241 - STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2019 EDITION
1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL BE MARKED WITH EXIT SIGNAGE.
(SECTION 7.10.1.2.1 OF NFPA 101-2018 EDITION)
2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS CORRIDOR. (SECTION 7.10.2.1 OF NFPA
101-2018 EDITION)
3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES WHERE EGRESS PATH
IS NOT OBVIOUS (SECTIONS 7.10.2.2 AND 7.10.1.2.2 OF NFPA 101-2018 EDITION)
4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (SECTION 7.10.1.5.2 OF NFPA 101-2018 EDITION)
5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (SECTION 7.10.9.1 IF NFPA 101-2018 EDITION)
6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE PROVIDED IN SUITES USED
BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL PUBLIC BACK TO THE WAITING AREA. (SECTION
7.10.2.1 OF NFPA 101-2018 EDITION)
7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE. (SECTIONS 13.2.10.1 AND
3.3.196.2 OF NFPA 101-2018 EDITION)
EXIT SIGN REQUIREMENTS
THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE JANUARY 31, 2020) BETWEEN THE VA AND TJC FOR IMPLEMENTATION OF TJC ENVIRONMENT OF CARE (EC) AND
LIFE SAFETY (LS) STANDARDS.
THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM (EFFECTIVE MARCH 29, 2019) BETWEEN THE VA AND THE LTCI FOR IMPLEMENTATION OF LIFE SAFETY
REQUIREMENTS.
THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT COMMISSION AND APPLY TO ALL BUILDINGS:
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS
2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET
3. INTERNAL SPRINKLER PIPING CONDITION AND OBSTRUCTION INVESTIGATION.
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL DISTANCE APPROVED SEPTEMBER 19, 2012.
EQUIVALENCIES
OCCUPANCY TABLE
Building No. Floor Health Care Ambulatory Health Care Business
Special Purpose Industrial Domiciliary Total
1 9-Penthouse 2,250 2,250
1 8-Penthouse 5,537 5,537
1 7 10,751 10,751
1 6 29,486 29,486
1 5 34,932 34,932
1 4 35,451 7,652 43,103
1 3 47,739 47,739
1 2 67,450 7,639 75,089
1 1 85,015 7,316 92,331
1 Basement 45,554 7,322 52,876
1 Sub-Basement 5,071 5,071
SUB TOTALS 297,888 0 88,419 12,858 0 399,165
GRAND TOTALS 297,888 0 88,419 12,858 0 399,165
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
FP&C Project Number 3252.00
SOC X-2
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
CODE SUMMARY AND
OCCUPANCY TABLE
UP UP
ELEV-4
ELEVATOR PIT
ELEV - 1
SUB 1
SUBBASEMENT FLOOR
SUB 2 SUB 3
ELEVATOR PIT
ELEV-3
ELEVATOR PIT
ELEV-2
CRAWL SPACE
ELEVATION CHANGE FROM 67' TO 71'
ELEVATION CHANGE FROM 67' TO 71'
PIT
ELEVATOR
SHIP LADDER
SHIP LADDER
SHIP LADDER
STAIR
UP
ELEVATOR PIT
DN
DN
MECH RM
UP
SUMP PIT
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
FP&C Project Number 3252.00
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED
ON FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END
CORRIDORS PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
1SOC-SB
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL
DISTANCE APPROVED SEPTEMBER 19, 2012.
SPECIAL PURPOSE INDUSTRIAL OCCUPANCY
FULLY SPRINKLERED
BUILDING 1 SUB-BASEMENT FLOOR
N
BUILDING 1 SUB-BASEMENT FLOOR
30 ft15 ft0 ft
0 ft 25 ft 50 ft 75 ft 100 ft
UP
DN
UP
UP
UP
H-B
F-B
CONCRETE PAD
CONCRETE PAD
CONCRETE PAD
DN
UP
UP
METAL GRATE STAIR
UP
CONCRETE PAD
METAL GRATE STAIR
METAL GRATE
CONCRETE PAD
STAIR
UP
CRAWL SPACE
SLOPE DN
METAL STAIRS
CONCRETE SLAB
TO
S
UB
-B
AS
EM
EN
T
AREA WAY
AREA WAY
AREA WAY
CRAWL SPACE
AREA WAYAREA WAYAREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAY
CRAWL SPACE
UP
AREA WAY
UP
DN
UP
LOUVER
DN
DN
LOUVER
CHAIN LINK GATE
METAL ROOF
OVERHEAD DOOR
FIRE DOOR
CHASE
BC4C
CHASE
BC14C
CHASE
BC40C
JANITOR
STAIRWELL
C-B
CORRIDOR
C21B
ELECTRICAL
CHASE
BC23C
CHASE
BC24C
ELECTRICAL
CLOSET
CHASE
BC13C
SHOWER
ELEVATOR
B-EL-2C
ELEVATOR
B-EL-1C
ELEVATOR
B-ME-1
TOILET
B-MT
CHASE
BC36C
HOUSE
KEEPING
D008
CHASE
BC8C
CHASE
BC7C
CHASE
BC6C
CHASE
BC34C
ELEC.
B-TC-L1
ELEC.
B-EC-L1
CHASE
BC30C
CHASE
BC29C
CHASE
BC28C
VESTIBULE
32A
VESTIBULE
33A
CHASE
BC27C
CHASE
BC26C
CHASE
BC25CCHASE
BC16C
CHASE
BC15C
STORAGE
B-B-CS-01
FIRE CLOSET
B-BFC-2
CHASE
BC22C
CHASE
BC21C
CHASE
BC20C
ELECTRICAL
CHASE
BC11C
CHASE
BC5C
CHASE
BC9C
CHASE
BC33C
CHASE
BC31C
CHASE
BC43C
CHASE
BC42C
CHASE
BC39CCHASE
BC38C
CHASE
BC37C
CHASE
BC32C
CHASE
BC19C
CHASE
BC18C
CHASE
BC35C
CHASE
BC17C
CHASE
BC12C
CHASE
BC10C
PURPLE
HEART ETC
3A
CHIEF
PROSTHETICS
DAV TRANSPT
EMERGENCY
POWER
D018A
ELECTRICAL
ELECTRICAL
13C
PUMP RM
WAITING AREA
LOBBY
L01
ELEVATOR
P-9
ELEVATOR
P-10
ELECTRIC
SWITCH GEAR
E003
E ELECTRICAL
E002
TEL COM
E001
STAIR-1
S01
FIRE PUMP RM
E006
MECHANICAL
E004
STORAGE
VA NURSING
ACADEMY
D014D
BREAK
RM
D014C
TELEPHONE
ACCESS
PROGRAM
D014B
EMERGENCY
POWER
D018
MEDGAS O2
NO2 STORAGE
105A
STAIR
K-B
CORRIDOR
C104
12H
TEL/DATA
RM
12 I
FMS OFFICE
D021A
SUMP
PUMP RM
D014A
CHASE
BC41C
MAIL RM
21A
ELEVATOR PIT
B-E5
CORRIDOR
B-L-1
STORAGE
2B
SECRETARY
SPEC PUR
ELEVATOR
P4
SERVICE
ELEVATOR
S1
ELEVATOR
P2
ELEVATOR
P3
CORRIDOR
C-C-C1
MORGUE
OFFICE
23B
LOCKER
ELECTRICAL
D017
ELECTRICAL
SWITCH GEAR RM
D016
CABLE RM
D016A
ELEVATOR MACHINE RM
D020
REPORTS
PRINTING
REPRODUCTION
UNIT
LOCKED
D006
UNION
OFFICE
D007
ELECTRICAL ENGINEERING
OFFICE
D005
WOMENS
TOILET
D004
MENS
TOILET
D003
NURSING ADMIN
STORAGE
D002
PATIENT
EFFECTS
D001
PART OF
MORGUE
MORGUE
23A
CANTEEN
OFFICE
D015
STAIRWELL 6C
G-B
CANTEEN
STORAGE
D023
ELECTRONICS
TECH OFFICE
D022OFFICE
D021
MEDICAL
RECORDS
D014
MEDIA
OFFICE AND
STORAGE
D014E
INTER PROFESSIONAL
SIMULATION CTR
D011
OFFICE
D013
OFFICE
D012
LEGAL
PROGRAM
ASSISTANT
D010
STAIR 4C
D-B STAIR 5C
E-B
MECHANICAL
RM
D009
STAIR
B-ST-1
STAIR
A-B
CORRIDOR
C-A-C1
EMS REPAIR
13A
OFFICES
KITCHEN
13B
TOILET
14B
LAUNDRY
14A
STORAGE
13D
REFRIGERATOR
WOMENS
TOILET
MENS
TOILET
33 STORAGE
ELECTRICAL
CLOSET
STAIRWELL
B-B
CORRIDOR
B-B-C1
CANTEEN
CANTEEN
EQUIPMENT
CANTEEN STORE
CANTEEN STORE
STORAGE RM
BARBER
SHOP
DIALY
SIS
C WING D WING
BUSINESS
OCCUPANCY
HEALTH CARE
OCCUPANCY
A WING
B WING
SC - WING
BB
SC - WING
BC-1
SC - WING
BA
SC - WING
BC-2
FMS AND ENGINEERING
EX
EX
EX
NON SRPINKLERED
D WING
C WING
EX
EX
CORRIDOR
B053-A
CORRIDOR
B053-A
CORRIDOR
B069-F
CLOSET
B069-E
UTILITY
JAN. CLO.
B051-B
CLOSET
B073-C
UTILITY
CLOSET
B069-D
UTILITY
CRASH CART
B069-G
OFFICE
B068
DR001
B055
DRESS. (M)
DR001
B056
DRESS. (M)
WTMRI
B058
SUB WAITING
LCCL3
B057
LINEN
CORRIDOR
B069-H
CORRIDOR
B053-B
TNPG1
B052
TOILET
WTG04
B050
WAITING
CORRIDOR
B051
USCL1
B074
SOIL UTILITY
TPG01
B073-B
TOILET
WTMRI
B073-A
SUB WAITING
XMRS1
B072
MRI 1.5T
XMRC2
B071-B
SYS. COMPONENT
XMRS1
B070
MRI 3T
XMRC1
B071-A
CONTROL
WRL01
B069-C
HOLD BAY 3
WRL01
B069-B
HOLD BAY 2
WRL01
B069-A
HOLD BAY 1
TPG01
B059
TOILET
MEDICATION
B062
SUPPLY
B063
STERILE
UCCL1
B064
CLEAN ROOM
TNPG1
B066
TOILET
SL001
B065
BREAK
OFDC2
B067
CONSULT/ VIEWING
RCP02
B054
RECEPTION
DR001
B061
DRESS. (F)
DR001
B060
DRESS. (F)
LC
MRI
UNDER DESIGN
DN
DN
12J
DIALYSIS
STORAGE
MECHANICAL
ROOM
TREATMENT
TREATMENT
TREATMENT
BATH
SHOWER
12A
CHIEF
12B
BATH
SHOWER
12D
OFFICE
12E
STORAGE
12F
OFFICE
OFFICE
STORAGE
ELECTRICAL
PROSTHETICS
OFFICE
BIO MED
STORAGE 19
STORAGE
CHIEF
PHYSICAL
THERAPY
BUSINESS
OCCUPANCY
HEALTH CARE
OCCUPANCY
North Stair
VERIFY FIRE RATED DOOR
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
FP&C Project Number 3252.00
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED
ON FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END
CORRIDORS PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
1SOC-B
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL
DISTANCE APPROVED SEPTEMBER 19, 2012.
MIXED OCCUPANCY
FULLY SPRINKLERED
BUILDING 1 BASEMENT FLOOR
N
BUILDING 1 BASEMENT FLOOR
30 ft15 ft0 ft
0 ft 25 ft 50 ft 75 ft 100 ft
SMOKE ZONE SQ. FT. OCCUPANCY
SMOKE ZONE SIZE
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
KEY NOTES:
CANOPY ABOVE
EXISTING ELECTRICAL
ROOM AREAWAY
H1
PASS
THRU
METAL
ACCESS PANEL
ELEVATING
AREA WAY AREA WAY AREA WAY
CORRIDOR
AREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAY
AREA WAYS
AREA WAY
AREA WAY
LOADING DOCK
PHARMACY
DOCK
D1007
D1016
D1024A
D-1 D1033A
D1006E
D144
D143
D1005
D145
D146
D147
D151B
D1006D D1020
D1022
D1010E D1008
D1009
D1006B
D1006C
D1006A
D1018
D1010D D1025
D1010C
D1017 D1021
D1010BD1010A D1031
D1014
158N
177 176 175
153152 153A
158A
158O
158B
158C
158D
158M
158L
158J
158E
158K
158F
158I
158H
D1044
D152
D1024
D1043
D1046
D1056
D1055 D1058
D1023 D1026
D1027
D1028
D1030
D1041
D1039
D1037
D1040
D1038
D1033
D1029 D1032
D1033B
ADVOCATE
D1035 D1036
D1034
D1047
D1048
D1050
D1049
D1051
D1061 D1057
D1063 D1062E
D1052 D1053
D1054
D1064
D1062A
D1065B
D1065A D1066E
158G
D1060 D1087
D1400
D1095E
D1091A
D1091E
D1059 D1083
D1062D
D1062C
D1086
D1084
D1091C
D1091D
D1062B
D1066D
D1066C
D1091B
D1095D
D1095C
D1066A
D1068E
D1068A
D1069
D1095A
D1097E
D1097A
D1066B
D1068D D1079
D1068C
D1068B
D1077
D1075
D1095B
D1097D D1080
D1097C
D1078
D1076 D1097B
D1070 D1071 D1089B D1089A D1089D
CORRIDOR
C1212-4
WORKER
SOCIAL
138A
149A
154A
157B
TOILET
TOILET
SPRINKLER ROOM
TOILET
164A
DRESSING
164B
CORRIDOR
C164
WAITING
RECEPTION
162A
HAC
OFFICE
172 MRI
SCANNER
CONTROL
ROOM
MRI
MRI
EQUIPMENT
MECH
175A
OFFICE
D148
OPTHALMOLOGY
C-1
B1
STAIR-G1
E-1
CARDIOLOGY
EKG/
ROOM
STRESS TEST
ROOM
DRESSING
FELLOWS
CARDIOLOGY
ELECTRICAL ROOM
STORAGE
C1212-2
CORRIDOR-3
LOUNGE
TOILET
OFFICE
D1178
CORRIDOR
D1175D
TREATMENT-4
ROOM
SECLUSION
D1177
MED ROOM TRIAGE
D1176
TREATMENT-3
D1173A
ADMITTING
D1173
CORRIDOR
C1175
TREATMENT-2 TREATMENT-1
D1175B D1175A
D1175E
ROOM
CLEAN
ISOLATION
UTILITY
C1172
CORRIDOR
PFT LAB
WAITING ROOM
D1171
OFFICE
VESTIBULE
D1170
EXISTING ELECTRICAL
ROOM AREAWAY
H1
D1179D
STAIR
STAIR WELL-C
D1179B
D1175C
D1179C
SOILED UTILITY
C1079
WELL-E
STAIR WELL-D
ED X-RAY SUITE
HOUSE KEEPING
TOILET
RECEIVING
MAIL OUT
122MAIL
SUPPLIES
CLEAN
STORAGE
121A
RESEARCH DRUG
STORAGE
REFRIGERATION
DISPENSING
VAULT
120A
FILLING AND
ASSEMBLY
OUTPATIENT
CORRIDOR
C119
FIRE
ALARM
CORRIDOR-0
1C27C
CLOSET
ELECTRICAL
CHASE
ROOM
1C9C
1C5C
CHASECHASE
1C6C
CHASE
1C10C
ELEVATOR
CHASE
C1-L-C5
CORRIDOR
1C7C
CHASE
1C8C
CHASE
1C11C
OFFICE
1C14C
CHASE
1C16C
CHASE
FIRE CLOSET
1C17C
CHASE
CLOSET
ELECTRICAL
JANITOR
PATIENT
PATIENT ADVOCATE
1C22C
CHASE
CHASE
1C20C
1C21C
CHASE
VESTIBULE
LOADING
STORAGE
OXYGEN
STORAGE
P6
RADIOACTIVE STORE
ELEVATOR
D140
D141
MENS
TOILET
CHASE
1025C
HAZARD
BIO
TENANT
EMPLOYEE
HEALTH
CORRIDOR
C1-MC-C4
CORRIDOR
D147B 1C40C
CLOSET
EMPLOYEE HEALTH
EMPLOYEE HEALTH
D151
ED X-RAY SUITE
OFFICE
D154
1C24C
D153
1C23C
CHASE
1C19C
CHASE
STARBUCKS
1-DW-1
DUMP WAITER
1C61C
1C18C
CHASE
STARBUCKS
1-L1
ELEVATOR LOBBY
1-TC1
TOWER
TELEPHONE
CLOSET
ELECTRICAL
1-EC-L1
PHONE RM
1C15C
CHASE
1-L-2
ELEVATOR LOBBY
ELEVATOR
SERVICE
ELEVATOR
ELEVATOR
ROOM
ENT EXAM
ROOM
ENT EXAM
CARDIOLOGY CARDIOLOGY
CARDIOLOGY ELECTRICAL
CLOSET
1C12C
CHASE
LAUNDRY
CHUTE
ELECTRICAL
CLOSET
ELECTRICAL
ROOM
HAC
ECHO LAB
ECHO LAB
CARDIOLOGY
EXAM ROOM
PULMONARY
C158S
CORRIDOR
PULMONARY
PULMONARY
EXAM
PULMONARY
PULMONARY
CARDIOLOGY
ROOM
DIRTY
BREAK
WOMENS
CORRIDOR
C166-1-C4B
ANTE ROOM/
GOWNED WAITING-2
OFFICE
MENS
WAITING ROOM
ULTRACARDIOLOGY
VASCULAR
OFFICE
CORRIDOR
C1C2A
C12C
CORRIDOR
CORRIDOR
C158Q
1-EL-8
ELEVATOR
1-EL-7
ELEVATOR
CHASE
1C54C
CHASE
CORRIDOR-5
1C51C
CHASE
EXAM
1C50C
D1179A
1C34C
CHASE
D1012
TRASH
D1210A
VEND OR LOADING
1C35C
CHASE
D1013
ELEVATOR LOBBY
1C36C
CHASE
OFFICES (DOCTORS) OFFICE OFFICE
1C33C
CHASE
1C32C
CHASE
1C31C
CHASE
1C30C
CHASE
C1-EMS-C0W
1C29C
CHASE
CHASE
1C28C
CHASE
EXAM
C13C
CORRIDOR
OFFICE
1C26C
CHASE
EXAM AND
OFFICE
EXAM
OFFICE
OFFICE
STORAGE
CORRIDOR-1
C1201-1-CP
OFFICE
EXAM EXAM
ELECTRICAL
D1006
VESTIBULE UTILITY
C1212-1
CORRIDOR
CORRIDOR-9
D1019
IN-TAKE
STORAGE
RECORD
SOCIAL
DISPOSITION
WORKEROFFICE
EXAM
OFFICE
EXAM
OFFICE
EXAM EXAM
VESTIBULE
D1003
EXAM
EXAM SUITE
TOILET
OFFICE
1C38C
OFFICE
EXAM
1C37C
CHASE
CHASE
S-5
ELEVATOR
D1015
SUB-WAITING
TREATMENT
ROOM
CONFERENCE
EXAM
OFFICE
TOILET
EXAM
1C45C
CHASE
ADVOCATE
PATIENT
C1203-1-CP
CORRIDOR-3
1C43C
CHASE
TOILET
1C44C
CHASE
OFFICEGERIATRICS
WORKER
SOCIAL
C1202-1-CP
CORRIDOR-2
1C39C
CHASE
SOCIAL
WORKER
OFFICE
DIABETIC
1C41C
CHASE
1C42C
CHASE
TOILET
1C47C
CHASE
OFFICE
OPEN
1C46C
CHASE STAIR
ELECTRICAL CLOSET
STAFF LOUNGE
OFFICE
OFFICE
C1210-1-CP
CORRIDOR-10
ROOM
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
EXAM
INTERVIEWDIETARY
BLOOD DRAW
C1205-1-CP
CORRIDOR-4
OFFICE
EXAM
OFFICE
OFFICE
EXAM
OFFICE
EXAM
OFFICE
EXAM
OFFICE
EXAM
C1206-1-CP
CORRIDOR-5
OFFICE
EXAM
OFFICE
EXAM
OFFICE
EXAM
OFFICE OFFICE
EXAM
ROOM
EXAM
D1042
BLOOD DRAW WAITING
C1-CPC-C5
CORRIDOR-11
NOD NURSE MANAGER
APPOINTMENTS
NEW
CHASE
1C49C
D1045
IN-TAKE
TOILET
CHASE
1C53C
CHASE
1C52C
OFFICE
NURSE
TAPS OFFICE OFFICE DECEDENT AFFAIRS APPOINTMENTS
CORRIDOR
AFFAIRS TESTING
TRAVEL
D1074
D1300
MAIN LOBBY
D1300E
AREA
D1210
CORRIDOR-10
OFFICE
EXAM
OFFICE
UTILITY
D1095
EXAM SUITE
OFFICE
1C60C
CHASE
EXAM EXAM
OFFICE
OFFICEOFFICE
EXAMEXAM
OFFICE
EXAM/
CHASE
EXAM
OFFICEOFFICE
EXAM
VESTIBULE
D1066
OFFICE
CLOSET
C1206-1-DP
EXAM
OFFICE
CORRIDOR-6
EXAM EXAM
OFFICE
D1068
OFFICE OFFICE
EXAM
VESTIBULE
OFFICE
EXAM
OFFICE
OFFICE
CHASE
CLOSET
TOILET
1C62C
C1201-1-DP
OFFICEOFFICE
EXAM
OFFICE
EXAM
D1097
EXAM SUITE
TOILET
1C63C
TOILET
CHASE
C1205-1-DP
OFFICE
VESTIBULE
D1062
EXAM
OFFICE
EXAM
TOILET
CHASE
1C58C SUB-WAITING
EXAM
D1082
ROOM
EXAM
ROOM
EXAM SUITE
D1091TOILET
1C59C
CHASE
OFFICE OFFICE
EXAM
DISPOSITION
PCA
INSURANCE
FLOATING
STORAGE
1C55C
RECORD
D1088
CHASE IN-TAKE
CORRIDOR-12
C1212-3
ADVOCATE
PATIENTMENTAL
HEALTHCOMMUNICATION
TELEPHONE
C1-DPC-C4
CORRIDOR
ELEC.
OFFICE
EXAM
WORKER
OFFICE
EXAM
SOCIAL
1C56C
LIVING WILL
CHASE CHASE
D1085
1C57C
C1207-1-DP
SUPPLY RM CORRIDOR-7
TOILET
CHASE
1C48C
TELECOM
E116
E ELEC
E115E114
N ELEC
STORAGE
E117
CLEAN
HOLDING
E110
RM
E111
EXAM-3
WORK
E113
EXAM-4
E109
E112
JC
E108
E105
E102
E107
UTILITY
SOILED
EXAM-2
E106
EXAM-1
NURSE
E104
TREATMENT
RECEPTION/
STATION
PROCEDURE/
E103
E101
WAITING
L12
LOBBY
ELEVATOR
LOBBY
L11
CORRIDOR
C11
S11
STAIR-1
MEDICATION
E121
ELEVATOR
ELEVATOR
CHASE
CLOSET
ELECTRICAL
CARDIOLOGY
OFFICE
UTILITY
PROSTHETICS
OFFICE
FELLOW
PULMONARY
SUITE
BRONCHOSCOPY
ROOM
EXAM
OFFICE
OFFICE
OFFICE
LAB
SOUND
DUCT SHAFT
CARDIO/
PULMONARY LAB
CARDIOLOGY
D151A
HOLTER MONITOR/
CHASE
CHASE
1C13C
ELIGIBILITY
MENS TOILET
ENROLLMENT
D1089E
RECEPTION
D1098
CHECK-IN
D1094
D1208
CORRIDOR-8
KIOSKS
D1300D
TRANSPORT
D1300A
DESK
D1300B
VESTIBULE
CHECK IN
D1090
OPERATIONS
POLICE
D1093
POLICE
CHIEF OF
D1300C
DESK
HELP
TOILET
MENS
D1089C
ENTROLLMENT
ELIGIBILITYANNUAL MEANSDECEDENT
SEATING
EXAM/
EXAM
ROOM
TOILET
WOMENS
HSKP
D1099A
D1300E
SCREENING
D1209
CORRIDOR-9
D1081A
ROOM
SCREENING
D1207
CORRIDOR-7
EXAM/
D1081B
SCREENING
SCREENING
D1081C
ROOM
D1081D
ROOM
D1210A
CORRIDOR
CHECK-IN-1
D1098B
CHECK-IN-2
D1098C
CHECK-IN-3
D1098D
CHECK-IN-4
D1098E
O-1
STAIR
P-9
P-10
STORAGE
TOILET
WOMENS
D1099 D1096
EX
PRIMARY CARE
CLINIC EV
LC
EX
REF
MICRO
REAR
FRONT
ELEV. No. 1
ELEV. No. 2
REAR
FRONT
DN
STAT/WORK
S125
NURSE
CLOSET
S147A
TPG01
S116
TOILET
TPB01
S119A
TOILET
STORAGE
S128A
RECEPTION
S108
STO.
S135A
CHAIR
ELEV 2
1BU
ELEV 1
1BT
LOB03
S103D
PHONE
AREA
S103E
CAFE
LINEN ROOM
S156
SOILED
SL001
S146
LOUNGE
OPMH4
S141
OPTH/AUDI
EMERG
S164C
CART
XCTS2
S161A
CT-MECH
CSED1
S153
DECON
TPMH1
S123A
TOILET
BX001
S103H
VENDING
CORRIDOR
S149
2HR RTD
S151
ELECTR. RM
SRE01
S137
EQUIP/SAFE ST.
TSPG1
S114A
TOILET
SRLW1
S103A
CHAIR STOR
TNPG1
S105
TOILET
TNPG1
S104
TOILET
TNPG1
S106
TOILET
STORAGE
S143A
LOCKER
S146A
STAFF
ROOM
S147
CONFERENCE
CORRIDOR
S112 CORRIDOR
S139
CORRIDOR
S135
CORRIDOR
S155
CORRIDOR
S150
STOR
S164B
ELEV LOBBY
S162
GROUND FL
ELEV LOBBY
S164
FIRST FL.
ROOM
S148
ELECTRIC
IT
S148A
CORRIDOR
S111 CORRIDOR
S145
DR001
S158
DRESSING
XDRC1
S159A
XRAY CONT.
XDR01
S159
GEN-RAD
XCTC1
S160
CT CONT.
XCTS1
S161
CT-SCAN
CONTRAST
S160ATPG01
S157
TOILET
EXTR1
S109
TRIAGE
OFDC2
S107
CONSULT
NCWD3
S138
NOURISHMENT
HEALTH
S114
WOMENS
TRPR1
S143
PROCEDURE
OFA09
S144
NURSE MNGR
LOB02
S140
CLEAN LINEN
EXTR1
S110
TRIAGE
SRLW2
S126
EMS STG
LOB02
S100
VESTIBULE (P)
NSTA4
S134
MH OBS
MEDP1
S133
MEDICATION
STERILE
S136
CLEAN UCCL1
S142
CLN-WORK
NT001
S125B
PNEU
TNPG1
S132
TOILET
JANC1
S163
ESD
WTG28
S103
WAITING
TNPG1
S129A
TOILET
LOB04
S103B
FOUNT
TRET4
S118
TREATMENT
TRET4
S113
FAST TRACK
TRET4
S115
FAST TRACK
BRAR1
S130
ANTEROOM
TPG01
S131A
TOILET
SHPU1
S153A
SHOWER
TRET4
S119
PROTECTED TREAT.
TRET4
S131
ISOLATION
TRET4
S120
TREATMENT
OPMH4
S123
MENTAL HEALTH
OPMH4
S122
MENTAL HEALTH
TRET4
S121
TREATMENT
TRET6
S129
BARIATRIC ISOL
TRET4
S117
TREATMENT
SRS01
S154
DECON-SUPPLY
RCA01
S125A
EMG CART
XRM01
S155A
IMG-EQUIP
TRET3
S128
CODE ROOM
LOB02
S127
VEST (A)
ENTRANCE
LOBBY
S101
UNDER
DESIGN
(NOT SURVEYED)
EX
EX
EX
SC - WING
1C-1
SC - WING
1D-1
SC - WING
1C-2
SC - WING
1B
A WING B WING
SC - WING
1A
SC - WING
1D-1
SC - WING
1D-2
EX EX
EX
EX
EX
RD
RD
BUSINESS
OCCUPANCY
HEALTH CARE
OCCUPANCY
CONFERENCE
B101
LOUNGE
B102
EMERGENCY
ELEC.
B104 COPY
B105
STORAGE
B106
OFFICE
B108
TOILET
B103
CORRIDOR
B100
CORRIDOR
B100
OFFICE
B109
OFFICE
B101
CORR.
B107
OFFICE
B110
CORR.
B120
ADMIN. OFFICE
B114
OFFICE
B112
CHIEF
B113
ADMIN. OFFICE
B115
CORRIDOR
B117
ADMIN. OFFICE
B116
MAIN
ELECTRICAL
B118
MECH.
B119
LC
NORTH STAIR
UPDN
EXIST.
SOUTH
STAIR
MRI
UNDER DESIGN
MECHANICAL ROOM
STAFF LOCKER
FEMALE
TOILET
MALE
TOILET
FEMALE
STAFF LOCKER MALE
113A
OFFICE
115A
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
BREAK / KITCHEN
109A
STAFF
WASHROOM
CONSULT
WAITING
STAIR TOWER-2
DROP
OFFICE
119C
PICK UP
119B
PU/DO
119A
OFFICE
ANESTHESIA
CONFERENCE ROOM
118A
ANESTHESIA
OFFICE
NURSE MANAGER
OFFICE
STAFF LOUNGE AND
CONFERENCE
STAIR K
K-1
CORRIDOR
CORRIDOR
101B
WOMENS
REST
ROOM 134
MENS
REST
ROOM
COMP
AND
PENSION
COMP
AND
PEN
PSYCHOLOGIST
COMP
AND
PENSION
COMP
AND
PENSION
RECEPTION
160A
COMP
AND
PENSION
COMP
AND
PENSION
VISN
100D
CLINICAL
MANAGER
100C
RPM CHECK /
PICK UP
STORAGE
MANAGER
OUPATIENT
PHARM
CLEANING
ROOM
CORRIDOR101A
CORRIDOR
CLEAN CORE
UNDER
DESIGN/
CONSTRUCTION
ELECTRICAL
WAITING
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
FP&C Project Number 3252.00
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED
ON FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END
CORRIDORS PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
1SOC-1
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL
DISTANCE APPROVED SEPTEMBER 19, 2012.
MIXED OCCUPANCY
FULLY SPRINKLERED
BUILDING 1 FIRST FLOOR
N
BUILDING 1 FIRST FLOOR
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
KEY NOTES:
30 ft15 ft0 ft
0 ft 25 ft 50 ft 75 ft 100 ft
SMOKE ZONE SQ. FT. OCCUPANCY
SMOKE ZONE SIZE
PHARMACIST
WORK
AREA
ACTIVE
STORAGE
RECEIVING
BREAKDOWN
253H
IV ANTEROOM
253B
IV PREP
253C
IV
PHARMACIST
WORK AREA
253J
HAZ. DRUG
ANTEROOM
253D
HAZ. DRUG
PREP AREA
253E
HAZ. DRUG
STOR.
253F
CLOSET
253G
INPATIENT
PHARMACY
MANAGER
SP
R
IN
K
LE
R
2-C-3C
CORRIDOR
251A
CORRIDOR
2-C-2C
CHASE
UP
DN
CT CABINET
DNUP
ROOF
DN
ROOF
ROOF
ROOF
ROOF
ROOF
DN
D217
D216
D219
D220
D221
D224 D223
D225
TOILET
D231D232D233D234D235
D215D212D211
D218D213D210
D209
D208
D206
D205
D222
D228 D204
D229B
D207
D203
D202
D201
239A
287 279
275A
254B238
235234
LINEN
CLOSET
265A
ELECTRICAL
266A
WAITING
SOUND
ANGIO ROOM
X-RAY
RM
MD OFFICE296
TOILET
MENS
TOILET
WOMENS
OFFICE
259 260
C2024
OR WAITING
CORRIDOR
C298
PACS OFFICE
STORAGE
TOILET
CT RM-1
CT RM-2
MEDICINE
HOT LAB
TESTING
STORAGE
TOILET
CORRIDOR
NUCLEAR
STRESS
C2O22
CORRIDOR
STAFF
LOCKERS
STAFF
STATION
X-RAY
OFFICE
MD OFFICE
ELEVATOR LOBBY
L-2
CORRIDOR
C2028
C2026
CORRIDOR
CLOSET
P4 P3
P2
S1
257A 258A
TC2
276A
254A
251B
D214
ELECTRIC CLOSET
D223A
WOMENS
MENS STAFF
CT GOWNING
RM
285A
TOILET
RM
CT CONTROL
STAIR
CLOSET
CLOSET
RM
TOILET
STORAGE
274A
CONTROL
X-RAY EXAM
C-2
B-2
G-2
E-2 D-2
2C13C
EXAM-1
E205
EXAM-2
E206
MICROSCOPE
E207
EXAM-3
E208
EXAM-4
E209
EXAM-5
E210
LOUNGE
E211
RESIDENTS
E215
EXAM-7
E217
EXAM-8
E218
PROCEDURE
E219
(STRETCHER)
E220
STAIR
S21
TOILET
E224
TOILET
E225
PHOTO THERAPY
E228
RECEPTION
E202
CAST RM
E204
JC
E203
TOILET
E212
UTILITY
E213
N ELEC
E214
E ELEC
E221
TELECOM
E222
CLEAN SUPPLY
E223
TOILET
E226
EQUIPMENT
E227
CORRIDOR
C21
CORRIDOR
C22
CORRIDOR
C25
CORRIDOR
C23
CORRIDOR
C24
WAITING
E201
EXAM-6
E216
LOBBY
L22
LOBBY
L21
NURSE STATION
E232
MED ALCOVE
E234
CONFERENCE/
EXAM-9
ELEVATOR
ELEVATOR
ELEVATOR
SOILED
LINEN CART
& EQUIPMENT
ALCOVE
CRASH CART
ALCOVE
CLOSET
260B
ELECTRICAL
260A
FILE RM
OFFICE
WAITINGRECEPTION
STORAGE
ELEVATOR
2C8C
CHASE
RECPT
2C14C
CHASE
2C12C
ELEVATOR2-TC-1L
TELEPHONE
CLOSET
ELEVATOR
CLOSET
CLOSET
2-DW-1C
WAITER
PHARMACY
C2-DC-1A
FIELD OPERATOR
MECHANICAL
2-EV-1C
ELEVATOR
STORAGE
246A 246B
OFFICE
PROGRAM CLERK
STORAGE
HISTOLOGY
2-EL-5
ELEVATOR
2-EV-4C
ELEVATOR
C2-4C
CORRIDOR
C2-7C
CORRIDOR
LAB STAFF CONFERENCE LAB MANAGER SECRETARY
SECRETARY
PATHOLOGIST
2C17C
CHASE
REGIONAL STAFF PATHOLOGIST
2-C-6C
DUCT SPACE
STORAGE BREAK RM
C2-5C
CORRIDOR
SEROLOGY LAB
SCIENCE
MICRO LAB
SCIENCE
ACCESS DISTRIB
COLLECTION
JANITOR
2C18C
CHASE
2C19C
CHASE
WOMENS
CHEMICAL LAB REFRIGERATOR
CHEMISTRY LAB CORE
HEMATOLOGY LAB
MICROBIOLOGY LAB
MICRO LAB
LAB
BLOOD BANK
C2-6C
CORRIDOR
BLOOD DONOR
ELEC.
BANK
2C20C
CHASE
C2200
CORRIDOR
2-C-8C
VESTIBULE
2C10C
CHASE
2C9C
CHASE
2-C-4B
CLOSET
2C11C
CHASE
RADIOLOGIS
2C15C
CHASE
X-RAY
RM
PASSENGER
STAIR
ELECTRICAL
PHARMACY
PHARMACY
IN-PATIENT
PHARMACY
LIBRARY
OFFICE
OFFICE
FELLOWS
STAIR PATHOLOGIST
STAIR
FLOUR MICA
OFFICE BLOOD
SUPERVISOR STAIR
CHIEF
C PATH
STORAGE
CLINICAL LAB LAB SCIENCE
CLINICAL LAB
SPECIMEN PROCESS
BLOOD SPECIMEN
MENS
TOILET
DUMB
COMMUNICATION
SERVICE
ELECTRICAL
PASSENGER
ELEVATOR
PASSENGER
TOILET TOILET
CHASE
ULTRA
BONE DENSETIZER
X-RAY
OFFICE
DIS WAITING
DIS
RECEPTION
296B
CHECK IN
296A
CHECK IN
ELECTRICAL
RADIOLOGISTRADIOLOGISTRADIOLOGIST
RADIOLOGIST
RADIOLOGIST
RADIOLOGIST
IRM
WORKSHOP
IRM STORAGE
TOILET
D226-1
TEL
O2
STORAGE
STAFF TOILET
MEDICATION
DRESS
272B
H.C.TOILET/
EQUIPMENT
272C
CONTROL
272A
STAFF LOUNGE
CHASE
ENDOSCOPY
CORRIDOR
S-C22
CORRIDOR
S-C21
FAMILY
WAITING
S202
FAMILY/
CONSULT
S203
SUPPLY
S229
TOILET
S204
STAIR
M-2
2-BED RM
S209
3-BED RM
S210
4-BED RM
S211
5-BED RM
S212
6-BED RM
S213
TEAM WORK
S235
PASSAGE
S230A
NOURISH
S232
NURSE
STATION-B
S236
NURSE
STATION-A
S230
CORRIDOR
S-C24
MEDS
S231
TOILET
S205
CLEAN UTILITY
S228
SOILED UTILITY
S227
TOILET
S216B
ISOLATION-2
S216
ANTE RM
S216A
BARIATIC BED-7
S217
BARIATRIC
TOILET
S217A
BARIATRIC
ISOLATION-1
S215
1-BED RM
S208
STAFF
LOCKER
S218A
STAFF LOUNGE
S218
TOILET
S219
PHYSICIAN
S220
NURSE
MANAGER
S221
TEL/DATA
S222
E. ELECT.
S223
ELECTRICAL
S224
ABG
S225
HSK
S233
EQUIP
S206
ALCOVE
STRETCHER
ALCOVE
PNEUMATIC
TUBE OXYGEN
STORAGE
S234
LINEN
S226
CORRIDOR
S-C23
PASSAGE
S230B
CONNECTOR
S-C20
UC FRIDGE
BARIATRIC
TOILET
S215B
ANTE RM
S215A
TOILET
S208A
TOILET
S209A
TOILET
S210A
TOILET
S211A
TOILET
S212A
TOILET
S213A
DN
ALCOVE
ALCOVE
ALCOVE
ALCOVE
FEC
STAFF
CORRIDOR
CLOSET
S201
ATS
ROOF
DN
UP
O-2
STAIR
P-9
P-10
D229A D230A
D230B
STAFF
STAFF
LC
LC
243C
WELLNESS
242A
PHARMACY
PHARMACY
PHARMACY
IN-PATIENT
238B
PHARMACY
IN-PATIENT
BREAK ROOM
WORK AREA
253A
VAULT
ROOF
2-EC-2A
ELEC.
PACU
LAB
SC - WING
2D
SC - WING
2C-1
SC - WING
2B
SC - WING
2C-2
SC - WING
2C-1
SC - WING
2S
SC - WING
2A
IMAGING
IN PATIENT
UP
EXIST.
SOUTH STAIR
STAFF CORRIDOR
CORRIDOR C
TREATMENT
ROOM CORRIDOR
WAITING
B201-A
MECHANICAL
B202
BUSINESS
OCCUPANCY
HEALTH CARE
OCCUPANCY
MRI
UNDER DESIGN
HEMODIALYSIS
UNDER DESIGN
ROOF
ROOF
CLEAN CORE
UNDER
DESIGN/
CONSTRUCTION
ANESTHESIA
WORKROOM
EQUIPMENT
STORAGE
WORK AREA
CONTROL
STATION
ANGIOPLASTY
OR-1
OR-2
OR-3
HOUSE
KEEPING
215G
SCRUB
210A
SCRUB
210B
OBSERVATION
ROOM
PACU
NURSE
STATION
215A
PATIENT
TOILET
CORRIDOR
C223
STAIR-K
K-2
STAFF
TOILET/SHOWER
1ST STAGE
RECOVERY
PRE-OP
HOLDING
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
PACU POST
OR
PRESURGERY
BED
215F
PATIENT
TOILET
215E
PATIENT
LOCKERS
215D
VESTIBULE
215C
CLEAN
UTILITIES
MINOR
PROCEDURE
215B
SOILED
UTILITIES
229A
IT
CLOSET
OFFICE
2-DC-1A
CORRIDOR
LINEN
CHUTE
A-2
STAIR
WELL
ELEC.
ELECTRICAL
CLOSET
232A
HOUSE
KEEPING
232D
ELEC
232C
ELEC
OR
STORAGE 233A
INTERVENTIONAL
PAIN
MANAGEMENT
CONSULT
ROOM
CORRIDOR
FEMALE
LOCKERS
202A
TOILET
201B
EMERGENCY
ELECTRICAL
201C
ELECTRICAL
ROOM
CORRIDOR
L23
ELEVATOR
LOBBY
SEMI
RESTRICTED
CORRIDOR
201A
OFFICE
LINK CORRIDOR
L24
CLEAN AND
STERILE
SUPPLY
EQUIPMENT
STORAGE
MECHANICAL
SEMI
RESTRICTED
CORRIDOR
A-EL-3
FUTURE
CLEAN
EL.
A-EL-2
FUTURE
CLEAN
EL.
CLEAN
AND
STERILE
SUPPLY
CC STORAGE
255A
NURSE
MANAGER
OFFICE
SOILED
UTILITY
IUSS
BRONCHOSCOPY
A-EL-1
FUTURE
SOILED
ELEVATOR
SEMI
RESTRICTED
CORRIDOR
CYSTOSCOPY
ELEC.
SEMI
RESTRICTED
CORRIDOR
OR ACCESS
VESTIBULE
OR ACCESS
VESTIBULE
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
FP&C Project Number 3252.00
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED
ON FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END
CORRIDORS PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
1SOC-2
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL
DISTANCE APPROVED SEPTEMBER 19, 2012.
MIXED OCCUPANCY
FULLY SPRINKLERED
BUILDING 1 SECOND FLOOR
N
BUILDING 1 SECOND FLOOR
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
30 ft15 ft0 ft
0 ft 25 ft 50 ft 75 ft 100 ft
KEY NOTES:
DOWN
RAMP
DN
RAMP
DN
312A
314A
345A
346B 346
356C
356A
356E
356G
355B
355D
349A
348A
347A
350A
348B
347C
347B
355C
355E
356B
358A
C357E
UTILITY SPACE
357A
357B
STAIR
S1
P2
P3
P4
TC-3
346A
310A
311A
333B
344A
356D
347D
347E
348C
ELEVATOR
B3 A-3
C-3
D-3 E-3
ELEC
OFFICE
INFECTION
CONTROL
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
EMER'CY
ELEC.
335B
OFFICE
OFFICE
OFFICE
OFFICE
PRIMARY CARE
OFFICE OFFICE
OFFICE
OFFICE
CONFERENCE
ROOM
OFFICE
OFFICE
OFFICE
STAIRHALL
VEST
335A
JANITORS
CORRIDOR
OFFICE
CHARTING
MENS
TOILET
318A
WOMENS
TOILET
318B
CLINICAL DIR
OFFICE
SECURE
STORAGE
STAFF
TOILET
303A
DISPENSARY
303B
SPECIMEN
TOILET
338A
CORRIDOR
C300
STORAGE
B F SPECIMEN
TOILET
338B
WAITING RM
STAFF
TOILET
307A
PSYCH OFFICE/
EXAM RM
SOCIAL
OFFICE
B F PATIENT
DISPENSARY
304A
PATIENT
DISPENSARY
304B
DIRECTOR
OFFICE
GROUP RM
STAFF
LOUNGE
JANITORS
3C3C 3C2C
3C1C
UP
THERAPY
E314
TELCOM
E322
N ELEC
E316
E ELEC
E321
STAIR
S31
CONSULT
E304
CONSULT
E305
CONSULT
E306
CONSULT
E307
CONSULT
E308
OFFICE
E309
DIRECTOR
E317 E318
SECRETARY ASSIST DIRECTOR
E319 E320
OFFICE
E325
GROUP 3
TOILET
E303
E311
TOILET
E329
E330
J C E313
STORAGE
E326
GROUP 1
E327E331
STAFF LOUNGE
ADMIN OFFICE
E312
E323
OFFICE
CONSULT
E315
NOURISH
E328
E302
RECEPTION
GROUP 2
E324
C31
CORRIDOR
C32
CORRIDOR
C33
CORRIDOR
CORRIDOR
C34
CORRIDOR
C35
WAITING
E301
LOBBY
L32
VESTIBULE
L31
ADMIN
E312A
SPECIALIZED
DN
ELEVATOR
ELEVATOR
ELECTRICAL
CLOSET
ELEVATOR
ELEVATOR
STAIRWELL
ELEVATOR
ELECTRICAL
ELECTRICAL
LINEN
BREAKOUT
DUMB WAITER
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
LOBBY
TOILET
CONFERENCE
OFFICE
DATA PROCESSING
OFFICE DATA PRO
OFFICE
CORRIDOR
CLOSET
STORAGE
OFFICE
OFFICE
STORAGE
VESTIBULE
OFFICE AREA
SOILED LTS
VESTIBULE
SOILED
MENS LOCKER ROOM
MENS TOILET
WOMENS LOCKER ROOM
WOMENS TOILET
STAIRWELL
JANITOR
UNIFORMS
FIRE CLOSET
UNIFORM ROOM
STERILIZATION
SOILED
UTILITY
STEAM STERILIZER
STAIRS
CORRIDOR
FIRE CLOSET
CLOSET
CLEAN - STERILE AREA
ETO STERILIZER
SANCTUARY
CHAPEL
DECONTAMINATION
STORAGE
CLOSET
SERVICE
COMMUNICATION
RECEIVING AND
ROOM
WORKER
SOCIAL
OFFICE
WORKER
3-FC-1
3-L-1
3-DW-1
C3-C-SPD-C1
348A1
355A
STORAGE
3-FC-2
357C
ELEVATOR
3-SE-C1
ELECTRICAL
VESTIBULE
ENDOSCOPE
PREPROCESSOR
356H
ENDOSCOPE
CLEANING
356J
OTP
BLESSED
SACRAMENT
CHAPEL
DISTRIBUTION
OFFICE
RECEIVING
STERILIZER
CHAPLAINS
(MEDICAL
310B
FILE ROOM
CHARTS)
388B
388A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
382B
TOILET
WOMENS
382A
TOILET
MENS381
JANITOR
STAFF RM
OFFICE
OFFICE
NEURO SCIENCE
NEURO SCIENCE
OFFICE
MECH RM
WAITING AREA
388C
OFFICE
388D
OFFICE
OFFICE
OFFICE
OFFICE
MECH RM
TOILET
BARIATRIC
OFFICE
OFFICE397
ADMIN AREA
397A
WAITING AREA
359A
OFFICE
OFFICE
TOILET
WOMENS
TOILET
MENS
362A
CLOSET
ELECTRIC
HALL
CLOSET
UP
ELEC.
364A
TELECOM
365A
CHUTE RM
365B
LINEN CHUTE
LINEN
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
NURSING
STORAGE
CORRIDOR
CHASE
CHASE
CHASE
OFFICE
OFFICE
ELECTRIC
DN
UP
316A
CORRIDOR
O-3
STAIR
328A
CLOSET
FIRE DOOR
P-9
P-10
MENS TOILET
TOILET
WOMENS
STAFF
STAFF
ROOF
ROOF
ROOF
LC
LC
SPD
B WING
UP
UP
EXIST. SOUTH
STAIR
ROOF
ROOF
HEMODIALYSIS
UNDER DESIGN
CONSULTANTS: OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT: STATEMENT OF CONDITIONS
LIFE SAFETY ASSESSMENT
08/06/2021 AF TK/KW
590 Means Street, Suite 200
Atlanta, Georgia 30318
(404) 214-9774
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE CONSULTANTS, L.L.C.
36C24121C0014
VISN 1 - New England Healthcare System
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
FP&C Project Number 3252.00
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED
ON FIRE RATED DOORS.
2. BUSINESS OCCUPANCY DEAD END
CORRIDORS PERMITTED TO EXCEED 50' FEET.
3. INTERNAL SPRINKLER PIPING CONDITION AND
OBSTRUCTION INVESTIGATION.
1SOC-3
PROVIDENCE VA MEDICAL CENTER
PROVIDENCE, RI
APPROVED SITE - SPECIFIC EQUIVALENCIES
1. MRI SUITE MEANS OF EGRESS AND TRAVEL
DISTANCE APPROVED SEPTEMBER 19, 2012.
BUSINESS OCCUPANCY
FULLY SPRINKLERED
BUILDING 1 THIRD FLOOR
N
BUILDING 1 THIRD FLOOR
30 ft15 ft0 ft
0 ft 25 ft 50 ft 75 ft 100 ft
UP
DN UP
458I
458A
458H 458G
458J
458K
458L
458F
458E
458C
458B
458A
447A
456A
454A
454B
C444
ROOF
S1
P2
P3
TC-4
P4
CORRIDOR
S-5
WALK-IN
FREEZER WALK-IN
FREEZER
C445
C456
459A
444A
458M
A-428
C-4
D-4
418A
2-BED PATIENT ROOM
2-BED PATIENT ROOM
PATIENT
BATHROOM
419A
2-BED PATIENT
ROOM
PATIENT
BATHROOM
420A
PATIENT
BATHROOM
422A
HVAC
CLOSET
421 BARIATRIC ROOM
PATIENT BATHROOM
423A
2-BED PATIENT ROOM
CORRIDOR
C436B
2-BED PATIENT
ROOM
PATIENT
BATHROOM
424A
MEDICATION ROOM
E.TELE/DATA
CLOSET
426A
E.SOILED LINEN
VESTIBULE
QUIET ROOM
1-BED PATIENT
ROOM
PATIENT
BATHROOM
411A
PATIENT
BATHROOM
410A
1-BED PATIENT ROOM
PATIENT
BATHROOM
412A
1-BED PATIENT
ROOM
PATIENT
BATHROOM
413A
1-BED PATIENT ROOM
ANTE ROOM
1-BED PATIENT
ISOLATION ROOM
414A
PATIENT
BATHROOM
414B
CORRIDOR
C436C
1-BED PATIENT ROOM
PATIENT
BATHROOM
415A
PATIENT
BATHROOM
416A
2-BED PATIENT ROOM
CORRIDOR
C436
NOURISHMENT AREA
417A
DAYROOM/ DINING ROOM
NURSE STATION
STAIRWAY CLEAN
LINE…