S02- Attach 11 Resolve Statement of Condition Deficiences addl drawings combined.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24823R0091
About this file
This document package includes construction plans and specifications for resolving deficiencies at the C.W. Bill Young VA Medical Center located in Bay Pines, Florida, as well as the related solicitation for construction services. The solicitation seeks proposals for project number 516-19-111 to provide construction work in accordance with the plans, which detail electrical demolition and new work on various floors of the interstitial spaces. Key aspects of the project include relocating and upgrading lighting fixtures, raceways, junction boxes and other electrical equipment. The magnitude of the project is estimated between $500,000 and $1,000,000. The solicitation is set aside 100% for service-disabled veteran-owned small businesses. The point of contact for the project is Joseph Wingfield, and proposals are due by August 15, 2021.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY PLAN B100
ELEV.
P-1 P-2
ELEV.
P-3
ELEV.
ELEV.
S-6S-5
ELEV.ELEV.
S-4
ELEV
S-7
ELEV
S-8
ELEV
S-9
ELEV
S-11
ELEV
S-12
ELEV
S-10
G.4
12111098
G.8
G
F.6
F.2
F.1
VF
D
F
DDC
ADD 20'
RU10
AHU-34
FIRST FLOOR INTERSTITIAL
ELECTRICAL DEMOLITION PLAN
ED101
0 4' 8'2'
1/4" = 1'-0"ED101
1 FIRST FLOOR INTERSTITIAL ELECTRICAL DEMOLITION PLAN
ED101 DEMOLITION NOTES
1. EXISTING SURFACE-MOUNTED
FLUORESCENT STRIP FIXTURE TO REMAIN.
2. DEMOLISH SURFACE-MOUNTED
FLUORESCENT STRIP FIXTURE AND
2#12;#12G;3/4"C. AS REQUIRED FOR FIXTURE
REMOVAL.
3. REMOVE, STORE, AND PROTECT METASYS
CONTROL ENCLOSURE FOR
REINSTALLATION. DEMOLISH
2#12,#12G,3./4"C. FROM VFD.
4. REMOVE, STORE, AND PROTECT VFD AND
DISCONNECT SWITCH FOR
REINSTALLATION. DEMOLISH
2#12,#12G,3./4"C. AS REQUIRED.
5. REMOVE, STORE, AND PROTECT DUCT
SMOKE DETECTOR FOR REINSTALLATION.
REMOVE 2#14,3/4"C. TO VFD.
6. DATA ENCLOSURE WITH FIBER OPTIC TAP
TO REMAIN.
7. AFTER INSTALLATION OF NEW DATA
CONDUIT AND INSTALLATION OF FIBER
OPTIC CABLE IN NEW RACEWAY, DEMOLISH
ABANDONED 1-1/2" EMT CONDUIT AND
PULLBOX. SEE SHEET E101, FIRST FLOOR
INTERSTITIAL ELECTRICAL NEW WORK
PLAN.
8. NORTH DATA PULL BOX TO REMAIN.
TRUE
NORTH
PLAN
NORTH
1. THE PROJECT'S ARCHITECTURAL SCOPE INCLUDES REPLACEMENT OF
MANY EXISTING DOORS. ELECTRICAL TRADE SHALL PROVIDE
DISCONNECTION AND RECONNECTION OF DOOR-MOUNTED SYSTEMS TO
INCLUDE BUT NOT LIMITED TO ELECTRIC STRIKES, MOTION DETECTORS,
MAGNETIC LOCKS, MAGNETIC SWITCHES, ETC. LOCATIONS OF DOORS ARE
SCHEDULED IN THE ARCHITECTURAL SHEETS. COORDINATE WITH
ARCHITECTURAL CONTRACTOR AND PROVIDE ALL ELECTRICAL WORK
REQUIRED TO SUPPORT DOOR REPLACEMENTS . PROVIDE ELECTRICAL
APPURTENANCES AS REQUIRED.
2. PROVIDE ALL ELECTRICAL DISCONNECTION AND RECONNECTION OF
EXISTING EQUIPMENT REQUIRED BY ALL TRADES. PROVIDE TEMPORARY
LIGHTING FOR ALL WORK IN INTERSTITIAL SPACES.
3. EXISTING FIRE ALARM SYSTEM IS BY SIMPLEX. ALL FIRE ALARM DEVICES
AND WORK SHALL BE BY SIMPLEX/JOHNSON CONTROLS. CONTACT BEN
JAYKO, AT (813) 917-9944 OR BENJAMIN.JAYKO@JCI.COM. PROVIDE ALL
HARDWARE AND SOFTWARE MODIFICATIONS AS REQUIRED TO CONNECT
ALL NEW DEVICES TO THE EXISTING SYSTEM. THIS WILL INCLUDE BUT NOT
LIMITED TO CONTROL PANEL CARDS, POWER SUPPLIES, RELAYS,
PROGRAMMING CHANGES SO THAT ALL NEW DEVICES FUNCTION
PROPERLY, AND DISPLAY ON THE GRAPHIC ANNUNCIATORS.
4. EXISTING ACCESS CONTROL SYSTEM IS BY JOHNSON CONTROLS. ALL
SYSTEM DEVICES AND WORK SHALL BE BY JOHNSON CONTROLS. CONTACT
FRANK DIMARCO, AT (813) 241-8561 OR FRANK.S.DIMARCO@JCI.COM.
PROVIDE ALL HARDWARE AND SOFTWARE MODIFICATIONS AS REQUIRED
TO CONNECT ALL DEVICES TO THE EXISTING SYSTEM. THIS WILL INCLUDE
BUT NOT LIMITED TO CONTROL PANEL CARDS, POWER SUPPLIES, RELAYS,
AND PROGRAMMING CHANGES SO THAT ALL NEW DEVICES FUNCTION
PROPERLY.
GENERAL ELECTRICAL NOTES
ELECTRICAL LEGEND
SURFACE-MOUNTED FLUORESCENT
LIGHT FIXTURES - SEE LIGHTING FIXTURE SCHEDULE
CONVENIENCE OUTLETS
J J
JUNCTION BOX WALL, CEILING
SWITCH OUTLETS
S
SPST TOGGLE SWITCH
CIRCUITS
FLEXIBLE RACEWAY
HOME RUN (ONE ARROW PER CIRCUIT)
CONDUIT (UP, DOWN)
EXPOSED RACEWAY
GENERAL EQUIPMENT
F
DISCONNECT SWITCH (F=FUSED, N=NON-FUSED)
FIRE ALARM EQUIPMENT
F
FIRE ALARM PULL STATION
F
FIRE ALARM COMBINATION AUDIBLE/VISIBLE APPLIANCE
HEAT DETECTOR
H
DUCT-MOUNTED SMOKE DETECTOR
TS
FS
TAMPER SWITCH
FLOW SWITCH
DEMOLITION PLANS
LINETYPES
EXISTING EQUIPMENT TO BE REMOVED
EXISTING EQUIPMENT TO REMAIN OR OTHERWISE NOTED
S
RACEWAY UNDERFLOOR, UNDERGROUND
ABBREVIATIONS
DDC
C, CD.
LTG
LED
UL
VFD
DIRECT DIGITAL CONTROLS
CONDUIT
LIGHTING
UNDERWRITER'S LABORATORY
VARIABLE FREQUENCY DRIVE
LIGHT EMITTING DIODE
EXISTING EQUIPMENT TO REMAIN OR OTHERWISE NOTED
NEW WORK AND EQUIPMENT
NEW WORK PLANS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RESOLVE STATEMENT OF
CONDITIONS DEFICIENCIES
BAY PINES, FL
516-19-111
Project Director
06/25/2021 RBP EGLRevisions: Date:
P R
O
F
E
S
S
I
O
N
A L
E
G
I
N
E
E
R
R
A
N
D
Y
B
P
E
A
C
O
C
K
L
I
C
E N
S
E
F
L
O
R I
D
A
No. 61366
STATE OF
AutoCAD SHX Text S
AutoCAD SHX Text
590 MEANS STREET NW STE. 200 ATLANTA, GA 30318
ELEV.
P-1 P-2
ELEV.
P-3
ELEV.
ELEV.
S-6S-5
ELEV.ELEV.
S-4
ELEV
S-7
ELEV
S-8
ELEV
S-9
ELEV
S-11
ELEV
S-12
ELEV
S-10
G.4
12111098
G.8
G
F.6
F.2
F.1
RU10
VFDF DDC
ADD 20'
AHU-34
FIRST FLOOR INTERSTITIAL
ELECTRICAL NEW WORK PLAN
E101
TRUE
NORTH
PLAN
NORTH
0 4' 8'2'
1/4" = 1'-0"E101
1 FIRST FLOOR INTERSTITIAL NEW WORK ELECTRICAL PLAN
# E101 NEW WORK NOTES
1. EXISTING SURFACE-MOUNTED
FLUORESCENT STRIP FIXTURE TO REMAIN.
2. EXTEND EXISTING LIGHTING CIRCUIT OF
2#12;#12G;3/4"C. TO NEW FIXTURES AND
THEN TO EXISTING-TO-REMAIN FIXTURE.
3. SURFACE-MOUNTED LITHONIA # CDS L48
MVOLT DM 40K 80CRI WH OR EQUAL LED
STRIP FIXTURE ON CEILING.
4. NEW ELECTRICAL EQUIPMENT SUPPORT
STRUCTURE OF 1-5/8" GALVANIZED B-LINE
STRUT COMPONENTS OR EQUAL.
STRUCTURE SHALL BE CONSTRUCTED
WITH MANUFACTURER'S GUSSET BRACING
COMPONENTS AND SECURED TO FLOOR
WITH EXPANSION ANCHORS. MOUNT
DISCONNECT SWITCH, VFD AND METASYS
CONTROL ENCLOSURE ON NEW
STRUCTURE.
5. INTERCEPT 2#12,#12G,3./4"C. AND REROUTE
TO DISCONNECT SWITCH, VFD, AND AHU.
6. REINSTALL AND RECONNECT DUCT SMOKE
DETECTOR. ROUTE 2#14,3/4"C. TO VFD.
7. INSTALL 1-1/2" EMT C. FROM NORTH DATA
PULL BOX TO DATA ENCLOSURE RU10.
AREA IS VERY CONGESTED. PROVIDE PULL
BOXES AS REQUIRED. LEAVE WITH PULL
STRING. SEE SHEET ED101, FIRST FLOOR
INTERSTITIAL ELECTRICAL DEMOLITION
PLAN.
8. OWNER WILL DISCONNECT, RELOCATE AND
TERMINATE EXISTING FIBER OPTIC CABLE.
NORTH DATA PULL BOX TO REMAIN.
9. INSTALL HEAT DETECTOR AND CONNECT
TO EXISTING INITIATION DEVICE IN SPACE
BELOW (POLICE DEPT). ROUTE 3/4"C. DOWN
THROUGH CONCRETE FLOOR INTO SPACE
BELOW.
10. 2#12,#12G;3/4"C. FOR 120V DDC POWER.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RESOLVE STATEMENT OF
CONDITIONS DEFICIENCIES
BAY PINES, FL
516-19-111
Project Director
06/25/2021 RBP EGLRevisions: Date:
P R
O
F
E
S
S
I
O
G
I
N
E
E
R
R
A
N
P
E
A
C
O
C
K
L
I
C
E N
S
E
F
L
O
R I
D
A
No. 61366
STATE OF
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text H
J
K
AHU-36
VFD
DDC
G
F.5
F.2
F
E.6
H
G.7
G.5
252423222120
J
D
E
15 16 17 18 19
D.4
ROOF
ROOF
KEY PLAN B100
J
K
AHU-36
VFD
DDC
SECOND FLOOR INTERSTITIAL
ELECTRICAL WORK PLANS
E102
PLAN
NORTH
TRUE
NORTH
0 4' 8'2'
1/4" = 1'-0"E102
1 SECOND FLOOR INTERSTITIAL ELECTRICAL DEMOLITION PLAN
1/4" = 1'-0"
SECOND FLOOR INTERSTITIAL ELECTRICAL NEW WORK PLAN
E102 DEMOLITION NOTES
1. MOVE CONTROLS JUNCTION BOX AND 3/4"C.
TO SOUTH SLIGHTLY TO CLEAR NEW WALL.
2. REMOVE, STORE, AND PROTECT
SURFACE-MOUNTED FLUORESCENT STRIP
FIXTURE TO BE RELOCATED. REMOVE
2#12,#12G;3/4"C. AS REQUIRED.
3. REMOVE (2) RUNS OF 3/4" EMPTY FLEXIBLE
METALLIC CONDUIT FROM DATA WIRE
TROUGH TO CONDUIT DOWN THROUGH
FLOOR TO REMAIN.
4. REMOVE DATA CABLE AND 3/4" EMPTY
FLEXIBLE METALLIC CONDUIT FROM DATA
WIRE TROUGH TO J-BOX LABELED "C119D
CAMERA ROOM" AND CONDUIT DOWN
THROUGH FLOOR TO REMAIN. DATA CABLE
TO BE REINSTALLED.
5. REMOVE 1/2" FLEXIBLE METALLIC CONDUIT
AND LOW VOLTAGE DDC CABLE. CABLE TO
BE REINSTALLED.
6. EXISTING STRIP FIXTURE MOUNTED ABOVE
VFD AND DDC PANEL TO REMAIN AND BE
RECONNECTED.
0 4' 8'2'
E102
# E102 NEW WORK NOTES
1. RELOCATED CONTROLS JUNCTION BOX
AND 3/4"C.
2. RELOCATED SURFACE-MOUNTED
FLUORESCENT STRIP FIXTURES.
3. SURFACE-MOUNTED LITHONIA # CDS L48
MVOLT DM 40K 80CRI WH OR EQUAL LED
STRIP FIXTURE ON CEILING
4. EXTEND EXISTING LIGHTING CIRCUIT OF
2#12;#12G;3/4"C. TO NEW FIXTURES AND
THEN TO EXISTING-TO-REMAIN FIXTURE.
5. INSTALL (2) RUNS OF EMPTY 3/4" C. FROM
DATA WIRE TROUGH TO CONDUIT DOWN
THROUGH FLOOR TO REMAIN.
6. INSTALL 3/4" C. FROM DATA WIRE TROUGH
TO J-BOX LABELED "C119D CAMERA ROOM".
REINSTALL DATA CABLE.
7. INSTALL 3/4" C. REINSTALL LOW VOLTAGE
DDC CABLE.
8. INSTALL HEAT DETECTOR AND CONNECT
TO EXISTING PULL STATION.
9. RECONNECT EXISTING STRIP FIXTURE
MOUNTED ABOVE VFD AND DDC PANEL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RESOLVE STATEMENT OF
CONDITIONS DEFICIENCIES
BAY PINES, FL
516-19-111
Project Director
06/25/2021 RBP EGLRevisions: Date:
P R
O
F
E
S
S
I
O
G
I
N
E
E
R
R
A
N
P
E
A
C
O
C
K
L
I
C
E N
S
E
F
L
O
R I
D
A
No. 61366
STATE OF
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text F
AutoCAD SHX Text F
G.5
G
252423222120
F.5
E.6
F.3
F
E
D.4
D
1918171615
H
J
K
G.7
27261413
H
25 26 27
H
DN
AD
AD
VFD DDC
AHU-40
25 26 27
H
DN
VFD DDC
AHU-40
FOURTH FLOOR INTERSTITIAL
ELECTRICAL PLANS
E103
TRUE
NORTH
PLAN
NORTH
0 4' 8'2'
1/4" = 1'-0"E103
2 FOURTH FLOOR INTERSTITIAL ELECTRICAL NEW WORK PLAN
0 4' 8'2'
1/4" = 1'-0"E103
1 FOURTH FLOOR INTERSTITIAL ELECTRICAL DEMOLITION PLAN
E103 DEMOLITION NOTES
1. SURFACE-MOUNTED FLUORESCENT STRIP
FIXTURE TO REMAIN (TYPICAL).
2. REMOVE, STORE, AND PROTECT DUCT
SMOKE DETECTOR FOR REINSTALLATION.
3. EXISTING WIREWAYS TO REMAIN.
4. DEMOLISH ABANDONED JUNCTION BOX
AND 3/4" C. FIRE SEAL ABANDONED FLOOR
PENETRATION.
5. REMOVE EMPTY J-BOX LABELED "4B DATA,
PATIENT BED, CATH LAB, FOOT END, GAS
BOX" TO BE RELOCATED. EMPTY 3/4"C.
DOWN THROUGH FLOOR TO REMAIN.
6. REMOVE J-BOX LABELED "4B, NLP1-13,"
2#12,#12G; 3/4" FLEXIBLE METALLIC
CONDUIT FROM WIREWAY. J-BOX TO BE
RELOCATED TO THE EAST TO CLEAR NEW
WALL.
7. REMOVE 2#12,#12G;3/4"C. LIGHTING CIRCUIT
TO CLEAR NEW WALL. CIRCUIT TO BE
REINSTALLED.
8. REMOVE 3/4"C. FIRE ALARM CIRCUIT TO
CLEAR NEW WALL. CIRCUIT TO BE
REINSTALLED.
9. J-BOX LABELED "IN USE X-RAY QLP1-29" AND
6#12,#12G' 3/4"C. TO BE RELOCATED TO
CLEAR NEW WALL. SCHEDULE OUTAGE
AFFECTING "IN USE X-RAY" WITH OWNER.
# E103 NEW WORK NOTES
1. SURFACE-MOUNTED LITHONIA # CDS L48
MVOLT DM 40K 80CRI WH OR EQUAL LED
STRIP FIXTURE ON CEILING. INSTALL
2#12,#12G;3/4"C. AS REQUIRED TO MAKE
CONNECTIONS.
2. REINSTALL AND RECONNECT DUCT SMOKE
DETECTOR.
3. RELOCATED J-BOX LABELED "4B DATA,
PATIENT BED, CATH LAB, FOOT END, GAS
BOX" MOUNTED ON WEST SIDE OF NEW
ENCLOSURE WALL. EXTEND EXISTING 3/4"C.
UP FROM FLOOR INSIDE NEW WALL TO
RELOCATED J-BOX. REROUTE EXISTING
EMPTY FLOOR-MOUNTED 3/4" C. TO NEW
J-BOX LOCATION.
4. RELOCATED J-BOX LABELED "4B, NLP1-13."
INSTALL 2#12,#12G; 3/4" FLEXIBLE METALLIC
CONDUIT FROM WIREWAY.
5. RELOCATED 2#12,#12G;3/4"C. LIGHTING
CIRCUIT TO CLEAR NEW WALL.
6. RELOCATED 3/4"C. FIRE ALARM CIRCUIT TO
CLEAR NEW WALL.
7. RELOCATED J-BOX LABELED "IN USE X-RAY
QLP1-29." INSTALL ADDITIONAL J-BOX FOR
SPLICES, REROUTE, AND SPLICE 6#12,#12G'
3/4"C.
8. INSTALL HEAT DETECTOR AND CONNECT
TO EXISTING INITIATION DEVICE AT SPACE
ENTRANCE DOOR.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F i l e
P a t h
FINAL SUBMITTAL
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RESOLVE STATEMENT OF
CONDITIONS DEFICIENCIES
BAY PINES, FL
516-19-111
Project Director
06/25/2021 RBP EGLRevisions: Date:
P R
O
F
E
S
S
I
O
G
I
N
E
E
R
R
A
N
P
E
A
C
O
C
K
L
I
C
E N
S
E
F
L
O
R I
D
A
No. 61366
STATE OF
AutoCAD SHX Text S
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text S
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text J
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text J
AutoCAD SHX Text J
| 4_FP101 |
| 5_ED101 |
| Sheets and Views |
| Layout1 |
| E101 |
| Sheets and Views |
| Layout1 |
| E102 |
| Sheets and Views |
| Layout1 |
| E103 |
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .