S02_Att3 DWGS Part 3 of 4 (2_Mechanical) 556-20-002 Replace Greenhouse Homes HVAC (CONST).pdf

PDF 29 MB Posted

Attached to
Z1DZ--556-20-002 Replace Greenhouse Homes HVAC (VA-22-00024652)
Solicitation number
36C25222B0015
Issued by

About this file

This federal contract opportunity notice is for replacement of HVAC systems in four housing buildings at the Captain James A Lovell Federal Health Care Center in North Chicago, Illinois. The solicitation number is 36C25222B0015 and will require the contractor to provide all labor, materials, equipment, and supervision to demolish existing HVAC systems and install new ductwork, air handling units, boilers, pumps, steam generators and controls in each of the four buildings. The work will be performed one building at a time over a 30 day period between buildings to allow for occupant relocation. The period of performance is 445 calendar days from notice to proceed. The estimated price range for construction is between $2,000,000 to $5,000,000. The solicitation will be issued on January 31, 2022 with bid opening on March 4, 2022. This opportunity is set aside for service-disabled veteran owned small businesses. The North American Industry Classification code is 238220 for plumbing, heating and air conditioning contractors with a $16.5 million small business size standard.

View the file

Other files

File Type Posted
36C25222B0015 0006.docx DOCX document
S02_Att8 Quality Requirements 01 40 00 19MAY20.pdf PDF
S02_Att12 Sec 05 12 00 Structural Steel Framing RFI Question No. 17.pdf PDF
S02_Att9 Regulatory Requirements 01 41 00 24JAN22.pdf PDF
S02_Att7 Infection Control Requirements 01 35 33 27AUG21.pdf PDF
S02_Att10 Definitions and Abbreviations 01 42 16 7APR17.pdf PDF
S02_Att6 Safer Federal Workforce Task Force guidance RFI Question No. 17.pdf PDF
36C25222B0015 0005.docx DOCX document
S02_Att11 Safety Requirements 01 35 26 27AUG21.pdf PDF
S04_2nd Site Visit Sign-In-Sheet 556-20-002 Replace Greenhouse Homes HVAC.pdf PDF
36C25222B0015 0004.docx DOCX document
36C25222B0015 0003.docx DOCX document
36C25222B0015 0002.docx DOCX document
S04_Site Visit Sign-In-Sheet 556-20-002 Replace Greenhouse Homes HVAC.pdf PDF
36C25222B0015 0001.docx DOCX document
S02_Att3 DWGS Part 1 of 4 (0_General) 556-20-002 Replace Greenhouse Homes HVAC (CONST).pdf PDF
36C25222B0015_1.docx DOCX document
S02_Att2 SPECS 556-20-002 Replace Greenhouse Homes HVAC (CONST).pdf PDF
S02_Att1 SOW 556-20-002 Replace Greenhouse Homes HVAC 21NOV21.pdf PDF
S02_Att5 VHA Directive 1192_01_D_2020-08-10 Seasonal Flu Shot.pdf PDF
S02_Att4 Wage Rates Determination pulled (02022022).pdf PDF
S02_Att6 Safer Federal Workforce Task Force guidance.pdf PDF
S02_Att3 DWGS Part 2 of 4 (1_Structural) 556-20-002 Replace Greenhouse Homes HVAC (CONST).pdf PDF
S02_Att3 DWGS Part 4 of 4 (3_Electrical) 556-20-002 Replace Greenhouse Homes HVAC (CONST).pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO. DESCRIPTION DATE

MILLER-REMICK LLC

PROFESSIONAL ENGINEER

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering

A Service Disabled Veteran Owned Small Business

MR PROJECT NO: 0513-0003

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

FOR CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ENGINEER OF RECORDCONSULTANT REPLACE HVAC -

GREENHOUSE HOMES

NORTH CHICAGO, IL

556-20-002

201, 202, 205, 206

Project Director

2021-07-15

321 4 5 6 7 8 9 10

A

B

C

D

21 4 5 6 7 8 9 10

A

C

D

E

F

E

F

MECHANICAL

TYPICAL PIPING DIAGRAMS

HEATING HW, NATURAL GAS

M-602

EBGE

M-001
MD111
MD112
MD113
MD114
MD121
MD122
MD123
MD124
MI121
MI122
MI123
MI124
MH111
MH112
MH113
MH114
MH121
MH122
MH123
MH124
MP121
MP122
MP123
MP124
M-301
M-501
M-601
M-602
M-701
M-702
M-801
M-802
M-901

File details come from the government source that posted it. Updated .