S02 - 695-22-121_100pc Bid Final_Drawings Part1.pdf
PDF 14 MB Posted
- Solicitation number
- 36C25226B0039
About this file
This document is a 100% Bid set of architectural drawings for the Building 111 Facade Repair project at Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The project involves comprehensive exterior facade restoration across multiple elevations of a federal Veterans Affairs facility.
The scope of work encompasses brick masonry veneer demolition and rebuilding, precast concrete panel repair, through-wall flashing installation, water-resistive barrier application, and sealant joint replacement across Elevations 1, 3, 21, 23, 25, and 26 on floors 9 and 11. Key repair activities include removing damaged brick masonry sections (both partial and full-wall areas between precast panels), salvaging and reusing intact brick units where possible, installing new stainless steel through-wall flashing with end dams at shelf angles, installing vertical cavity closure flashing at precast concrete interfaces, and applying fluid-applied air/moisture barriers over existing concrete masonry unit (CMU) backup walls. The drawings detail crack and spall repairs to precast concrete panels with repair quantities specified by panel designation for each elevation. Additional work includes removing and replacing existing sealant at precast concrete panel joints and window perimeter joints, installing new two-stage sealant joints, cleaning and applying clear penetrating water repellent to masonry surfaces, and providing new stainless steel masonry wall ties. The project includes coordination requirements to maintain continuous utility service to unaffected building areas and protection of adjacent systems during construction. Detailed section drawings and specifications address flashing configurations, masonry rebuild procedures, concrete repair methods, joint sealant applications, and interface conditions at shelf angles, window openings, expansion joints, and corner locations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02 - 695-22-121_100pc Bid Final_Drawings Part2.pdf | ||
| S02 - 36C25226B0039 PRE-SOL 695-22-121 9.23.2026.pdf | ||
| 36C25226B0039.docx | DOCX document | |
| S02 - 695-22-121_100pc Bid Final_Specification.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
NORTH
VICINITY MAP
PROJECT TEAM DRAWING SHEET INDEX
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.bodwegroup.com
1635 Prince Street Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
NORTH
LOCATION MAP
VA MILWAUKEE CAMPUS
Au to de sk
D oc s:
//2
VA
M ilw au ke e Bl dg
F ac ad e W or k/
V
A M ilw au ke e
Bl dg
F ac ad e
W or k-
AR
C H
_R
.rv t
3/
/2
:2 0:
P
M
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
ALLIANCE | SEVEN GENERATIONS A+E JV
600 E. MICHIGAN AVENUE, Ste B
KALAMAZOO, MI 49007
PHONE: 269.927.0144
BODWEGROUP.COM
5000 W NATIONAL AVE
MILWAUKEE, WI, 53295
WISS, JANNEY, ELSTNER ASSOCIATES, INC.
330 PFINGSTEN ROAD
NORTHBROOK, IL 60062
847.272.7400
WJE.COM
HAZARDOUS MATERIAL SPECIALIST
ARC ENVIRONMENTAL
FAÇADE REPAIR CONSULTANT
1635 PRINCE STREET
ALEXANDRIA, VA 22314
PHONE: 202.617.8485
ALLIANCE.US.COM
CLEMENT J. ZABLOCKI VA MEDICAL CENTER
BUILDING 111 FACADE REPAIR
MILWAUKEE, WISCONSIN
MILWAUKEE, WISCONSIN
ARCHITECTURE/COST ESTIMATING:
TITLE SHEET BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE,
WI, 53295
695-22-121
PROJECT DIRECTOR
MARCH 16, 2026 JD NL
100% BID DOCUMENTS
G001
1311 HAUBERT STREET
BALTIMORE, MD 21230
443.864.7464
ARCENVIRONMENTAL.COM
SHEET DESCRIPTION
GENERAL
G001 TITLE SHEET
G002 GENERAL INFO & SYMBOL LEGEND
G003 ROOF PLANS AND ISOMETRICS
G004 ROOF AND ELEVATOR ACCESS FLOORS 1 AND 3
G005 ROOF PLAN ACCESS INFORMATION FLOORS 9 AND 11
ARCHITECTURAL
A200 EXTERIOR ELEVATIONS - 3 AND 1 (NORTH)
A201 EXTERIOR ELEVATIONS - 21 (SOUTH)
A202 EXTERIOR ELEVATIONS - 23 (SOUTH)
A203 EXTERIOR ELEVATIONS - 25 (SOUTH)
A204 EXTERIOR ELEVATIONS - 26 (WEST)
A300 ENLARGED ELEVATIONS
A301 WALL SECTIONS AND DETAILS
A302 REPAIR DETAILS
A303 REPAIR DETAILS
HAZARDOUS MATERIAL
HA200 HAZARDOUS MATERIALS LOCATION PLAN ELEVATIONS 3 AND 1 (NORTH)
HA201 HAZARDOUS MATERIALS LOCATION PLAN ELEVATIONS 21 (SOUTH)
HA202 HAZARDOUS MATERIALS LOCATION PLAN ELEVATIONS 23 (SOUTH)
HA203 HAZARDOUS MATERIALS LOCATION PLAN ELEVATIONS 25 (SOUTH)
HA204 HAZARDOUS MATERIALS LOCATION PLAN ELEVATIONS 26 (WEST)
PROJECT LOCATION
100% BID DOCUMENTS
BUILDING 111
Revisions: Date:
ARCHITECTURAL ABBREVIATIONS
@ AT
A/C AIR CONDITIONING/AIR CONDITIONER
ACOUS ACOUSTICAL
ADJ ADJUST, ADJUSTABLE
AL ALUMINUM
AP ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
B BASE
BAR BARRIER
BD BOARD
BF BARRIER FREE
BKT BRACKET
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
CAB CABINET
CE COLUMN ENCLOSURE
CIR CIRCLE
CL CENTER LINE
CLG CEILING
CLR, CLEAR CLEARANCE
CJ CONTROL JOINT
CLO CLOSET
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CSS CLINICAL SERVICE SINK
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA, D DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
EJ EXISTING EXPANSION JOINT
ELECT ELECTRICAL
ELEV ELEVATION
ENTR ENTRANCE
EQ EQUAL
EP ELECTRICAL PANEL
EXH EXHAUST
EXP EXPOSED
EXIST EXISTING
EXT EXTERIOR
EW EACH WAY
FA FIRE ALARM
FD FIRE DAMPER OR FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FL, FLR FLOOR
FLG, FLRG FLOORING
FURN FURNITURE, FURNACE
FWC FABRIC WALL COVERING
FT FEET, FOOT
GALV GALVANIZE(D)
GL GLASS
GWB GYPSUM WALLBOARD
GYP. BD GYPSUM BOARD
ID INSIDE DIAMETER
INSUL INSULATION
IN INCH(ES)
JAN, JC JANITOR'S CLOSET
HM HOLLOW METAL
HORIZ, HOR HORIZONTAL
HR HANDRAIL
HT HEIGHT
HW HEADWALL
LAM LAMINATED
LF LINEAL FEET
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MANUF MANUFACTURED, MANUFACTURER
MIN MINIMUM
MLD'G MOLDING
MTL METAL
N NORTH
NAT NATURAL
NIC NOT IN CONTRACT
NORM NORMAL
NTS NOT TO SCALE
O.C. ON CENTER
OPN'G OPENING
O, O2 OXYGEN
PLAST PLASTIC
PNT PAINT
PREFAB PREFABRICATED
PLYWD PLYWOOD
R RADIUS
RA RETURN AIR
REQ'D REQUIRED
RM ROOM
S SINK, SOUTH, SHINGLE
SA SUPPLY AIR
SAN SANITARY
SD SMOKE DAMPER
SECT SECTION
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS SERVICE SINK, STAINLESS STEEL
STD STANDARD
STOR STORAGE
SUSP SUSPEND(ED)
SYM SYMBOL, SYMMETRICAL
TLT TOILET
TYP TYPICAL
UNFIN UNFINISHED
UTIL UTILITY
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VERT VERTICAL
VIF VERIFY IN FIELD
VT VINYL TILE
VWC VINYL WALL COVERING
W/ WITH
WC WATER CLOSET
WD WOOD
WNDW WINDOW
W. HTR WATER HEATER
W/O WITHOUT
WP WALL PROTECTION
ARCHITECTURAL SYMBOLS & PLAN INDICATORS
ELEVATION INDICATION
ENLARGED PLAN OR
DETAIL CALLOUT
PROPOSED SPOT
ELEVATION
EXISTING SPOT
ELEVATION
100.57'
100.57'
FLOOR JOIST OR
ROOF TRUSSES
STRUCTURAL SPAN
RAMP
@ 16" O.C.
2 x 12
1" per 12"
SLOPE UP
REVISION TAG W/
REVISION NUMBER
KEYNOTE TAG
WINDOW TAG W/
WINDOW TYPE
WALL SECTION CUT
COLUMN LINE
WALL TYPES
EXTERIOR ELEVATION
INDICATOR
BUILDING SECTION CUT
SHEET LOCATION
DETAIL NUMBER TYPICAL
DIMENSIONING
SET-BACK LINE
PROPERTY LINE
DOOR TAG W/
DOOR NUMBER
ROOM NAME/
ROOM NUMBER
60" DIAMETER CLEAR
WHEELCHAIR TURNING
SPACE - REFER TO PLAN
30" x 48" CLEAR FLOOR
AND GROUND SPACE
- REFER TO PLAN
CEILING HEIGHT TAG
EXISTING DOOR
NEW DOOR
DOOR IDENTIFICATION
DOOR TO ROOM SHALL REPEAT ROOM
NUMBER ASSIGNED TO ROOM. MULTIPLE
DOORS TO ROOM SHALL REPEAT ROOM
NUMBER WITH A POSTSCRIPT LETTER FOR
EACH ADDITIONAL DOOR REQUIRED.
101/101A/101B FOR NUMBER NEEDED.
DOOR IDENTIFICATION BY FLOOR
AND/OR ZONE SHALL BE AS FOLLOWS:
BASEMENT DOORS
FIRST FLOOR DOORS
SECOND FLOOR DOORS
THIRD FLOOR DOORS
CONTINUE FOR AS MANY FLOORS AS
REQUIRED.
ZONE A
ZONE B
ZONE C
A101 B101 C101
VIF
XX'-XX"+/-
XX'-XX"
NAME
ELEV. 100'-0"
View Name
SCALE: 1/8" = 1'-0"
AD101
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH
View Name
SCALE: 1/8" = 1'-0"
TYPICAL TITLE FOR
PLAN VIEWS
W/ NORTH ARROW
AXXX
AXXX
AXXX
AXXX
4'-4"
A
W1
X
AX XX
XX
INTERIOR ELEVATION
INDICATOR
A100
A1.1
ROOM NAME
MAUSOLEUM
N. WASHINGTON DR.
WAREHOUSE WAY
VOLUNTEER DR.
AMBULANCE WAY
S. WASHINGTON DR.
S. WASHINGTON DR.
N.
W
AS
HI
NG
TO
N
DR
CONTRACTOR PARKING
W NATIONAL AVE.
W NATIONAL AVE.
CONTRACTOR LAY
DOWN SPACES
AMBULANCE DRIVE
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
GENERAL INFO & SYMBOL LEGEND BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JD NL
100% BID DOCUMENTS
G002
NORTH
SCALE: 1" = 200'
VA MKE CAMPUS MAP
ROOF ACCESS DOOR
ROOF ACCESS DOORS
ROOF ACCESS DOORS
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
ROOF PLANS AND ISOMETRICS BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JD NL
100% BID DOCUMENTS
G003
NORTH
SCALE: 1" = 40'-0"
ROOF PLAN LEVEL 3
NORTH
SCALE: 1" = 40'-0"
ROOF PLAN LEVEL 9
NORTH
SCALE: 1" = 40'-0"
ROOF PLAN LEVEL 11
SCALE:1 ROOF ISOMETRIC LEVEL 3
SCALE:2 ROOF ISOMETRIC LEVEL 9
SCALE:3 ROOF ISOMETRIC LEVEL 11
ROOF ACCESS DOORSROOF ACCESS DOORS
ROOF ACCESS DOOR
FA
C
A D
E
FA
C
A D
E
GLASS STRUCTURE
CONTRACTOR LAY DOWN SPACE
C
O N
TR
A
C
TO
R
LA
Y D
O W
N S
PA
C
E
C O
N
TR
A C
TO
R
LA
Y
D O
W N
S
PA
C E
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
ROOF AND ELEVATOR ACCESS FLOORS 1
AND 3
BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JD NL
100% BID DOCUMENTS
G004
SCALE: 1" = 20'-0"2 3RD FLOOR ROOF ACCESS
SCALE: 1" = 20'-0"1 1ST FLOOR CONTRACTOR ROUTE TO ELEVATORS
FA
C
A D
E
FACADE 26
FA
C
A D
E
FA
C
A D
E
FACADE 2
FA
C
A D
E
FA
C
A D
E
FACADE 24
FACADE 22
SO
LA
RI
UM
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
ROOF PLAN ACCESS INFORMATION FLOORS 9
AND 11
BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JD NL
100% BID DOCUMENTS
G005
SCALE: 1" = 20'-0"2 11TH FLOOR ROOF ACCESS
SCALE: 1" = 20'-0"1 9TH FLOOR ROOF ACCESS
(975.67)
LEVEL 01
ELEV. 83'-8"
LEVEL 02
ELEV. 97'-5 3/8"
LEVEL 03
ELEV. 111'-2 3/4"
LEVEL 04
ELEV. 122'-9 3/8"
LEVEL 05
ELEV. 134'-4"
LEVEL 06
ELEV. 145'-10 5/8"
LEVEL 07
ELEV. 157'-5 1/4"
LEVEL 08
ELEV. 168'-11 7/8"
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
AA CC FF GG HH JJ KK NNLL MM
3A3 3B3
3B4
3B5
3B6
3B7
3B8
3B9
3B10
3A4
3A5
3A6
3A7
3A8
3A9
3A10
1D3
1D4
1D5
1D6
1D7
1D8
1D9
1D10
1C3
1C4
1C5
1C6
1C7
1C8
1C9
1C10
1B3
1B4
1B5
1B6
1B7
1B8
1B9
1B10
1A3
1A4
1A5
1A6
1A7
1A8
1A9
1A10
ELEVATION 3 (NORTH) ELEVATION 1 (NORTH)
LOWER BUILDING ROOF
ELEV. 112'-0 3/4"
12"-16" 12"-16" +/-2'-6" +/-4'-0" +/-6'-4" +/-4'-0"
EJ EJ
EJ
EJEJ
C BC
A
D
F
E
GLASS STRUCTURE
N O
T
IN
S C
O
PE
A300
NOT IN SCOPE.
PROTECT DURING THE WORK.
A300
SEE 1/A200 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 2
TYP.
TYP.
PROTECT EXISTING SOLARIUM. DO NOT
DAMAGE EXISTING SOLARIUM FRAMING
AT BRICK MASONRY EXTERIOR WALL
DURING THE WORK. REMOVE EXISTING
SURFACE-MOUNTED FASTENERS, AS
REQUIRED TO COMPLETE THE WORK.
REPLACE FASTENERS WITH NEW S.S.
FASTENERS TO MATCH EXISTING. INSTALL
NEW BACKER ROD AND SEALANT AT
JOINT BETWEEN SOLARIUM FRAME AND
NEW BRICK MASONRY VENEER.
REMOVE EXISTING SEALANT AND BACKING
MATERIAL AND INSTALL NEW BACKER ROD
AND SEALANT AT JOINT BETWEEN PRECAST
CONCRETE PANELS AND ROOF BASE
FLASHING PER 1/A303, TYP.
A301 TYP.
E
A301 TYP.
TYP.
J
ALT.
A
G
H
A301 TYP.
A301 TYP.
EJ
A300
SYMBOLS LEGEND
TOP OF STEEL
ELEV. 10'-0"
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
ENLARGED PLAN OR
SECTION INDICATOR
ORIGINAL
WINDOWS
COLUMN LINE
ELEVATION
INDICATOR
TYPICAL
DIMENSIONING
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH ARROW
4'-4"
NORTH
A320
A 1.X
A 1.X
MATCH LINE
VIEW REFERENCE
1 View Name
SCALE: 1/8" = 1'-0"
A1.1
? KEYNOTE TAG
LOUVER
REMOVE AND REBUILD
BRICK MASONRY
EJ
EXISTING VERTICAL
EXPANSION JOINT IN
BRICK MASONRY VENEER
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
REFER TO SYMBOL LEGEND, GENERAL NOTES, KEYNOTES AND
DRAWINGS FOR EXTENT OF WORK
VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
PORTIONS OF EXISTING CONSTRUCTION MAY HAVE BEEN
MODIFIED BY OWNER.
MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN
THE BUILDING NOT AFFECTED BY THIS WORK. COORDINATE
WITH COR ANY DISRUPTION IN SERVICES REQUIRED TO
PERFORM WORK OR TO MODIFY EXISTING PIPING,
DUCTWORK OR ANY ASSOCIATED EQUIPMENT.
ANY ADJACENT SYSTEMS OR COMPONENTS DAMAGED
DURING THE WORK SHALL BE REMOVED COMPLETELY AND
REPLACED IN KIND AT NO COST TO THE OWNER.
KEY PLAN
N
� 2
KEYED NOTES
REMOVE 12"-16" WIDE SECTIONS OF EXISTING BRICK MASONRY
VENEER ADJACENT TO PRECAST CONCRETE PANEL EDGES FULL HEIGHT
OF THE EXTERIOR WALL. REMOVE BRICK MASONRY UNITS TO
MAINTAIN EXISTING RUNNING BOND TO ACCOMMODATE TOOTHING
IN REPLACEMENT BRICK MASONRY UNITS. INSTALL NEW THROUGH-
WALL FLASHING WITH END DAMS AT SHELF ANGLES AND VERTICAL
CAVITY CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE
PANELS. REBUILD VENEER WITH BRICK MASONRY SALVAGED FROM
ELEVATIONS 1, 23, AND 26 (PRIMARILY AT CENTER PANELS). SALVAGED
BRICK MASONRY UNITS ARE TO BE TOOTHED IN WITH EXISTING BRICK
MASONRY TO REMAIN. DO NOT SALVAGE/USE REMOVED BRICK
MASONRY UNITS WITH JOINT SEALANT RESIDUE PRESENT. SEE 2/A300,
TYP.
A
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS. INSTALL NEW THROUGH-WALL
FLASHING WITH END DAMS AT SHELF ANGLES, VERTICAL CAVITY
CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE PANELS,
AND FLUID-APPLIED AIR/MOISTURE BARRIER OVER EXISTING CMU
BACKUP. REBUILD VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, AND FINISH. SALVAGE EXISTING BRICK UNITS
WHERE POSSIBLE FOR USE AT OTHER REBUILD AREAS. SEE 1/A300, TYP.
AFTER COMPLETION OF MASONRY REPAIRS, CLEAN EXISTING
MASONRY AND APPLY CLEAR PENETRATING WATER REPELLENT OVER
EXTERIOR SURFACE OF ALL BRICK MASONRY WALL AREAS.
MARK NOTES
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS AND EXISTING VERTICAL
EXPANSION JOINTS AT THE CORNER FULL HEIGHT OF THE EXTERIOR
WALL. INSTALL NEW THROUGH-WALL FLASHING WITH END DAMS AT
SHELF ANGLES, VERTICAL CAVITY CLOSURE FLASHING AT INTERFACE
WITH PRECAST CONCRETE PANELS, AND FLUID-APPLIED AIR/MOISTURE
BARRIER OVER EXISTING CMU BACKUP. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE, COLOR, AND FINISH.
SALVAGE EXISTING BRICK UNITS WHERE POSSIBLE FOR USE AT OTHER
REBUILD AREAS. SEE 1/A300, TYP.
REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL AND
INSTALL NEW TWO-STAGE SEALANT JOINT AT PRECAST CONCRETE
FASCIA BAND AND WALL PANEL JOINTS PER 2/A303, TYP.
B
C
D
E
F
CLEAN EXISTING PRECAST CONCRETE PANELS TO REMOVE SURFACE
SOILING IN PREPARATION FOR CONCRETE REPAIR COLOR MATCHING.
CLEANING TRIALS AT A LOCATION SELECTED DURING CONSTRUCTION
WILL BE REQUIRED TO FINALIZE THE MOST EFFECTIVE CLEANING
APPROACH. AFTER CLEANING AND REPAIRS ARE COMPLETED, APPLY
CLEAR PENETRATING WATER REPELLENT OVER EXTERIOR SURFACE OF
ALL PANELS.
G
AT ALL PUNCHED OPENINGS WITH ORIGINAL WINDOWS OR LOUVERS
IN PLACE, REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL
AND INSTALL NEW BACKER ROD AND SEALANT PER 1/A303. TYP.
H
I
J
PERFORM ISOLATED REPAIRS AT CRACKS AND SPALLS IN PRECAST
CONCRETE PANELS. REPAIR LOCATIONS AND APPROXIMATE
QUANTITEIS ARE INDICATED IN THE TABLES ABOVE. SEE 8, 9, AND
10/A302, TYP.
ALTERNATE 1 - IN LIEU OF FULL DISASSEMBLY AND RECLADDING,
PERFORM REPAIRS PER KEYNOTE A ALONG THE PRECAST CONCRETE
PANEL EDGES PER 2/A300, TYP.
ALTERNATE 2 - IN LIEU OF EXTENDING EXTERIOR WALL REPAIRS
AROUND INSET CORNER TO PRECAST CONCRETE PANEL ON NEXT
ELEVATION PER 3/A300, TERMINATE REPAIRS AT INSET CORNER PER
2/A302, SIM. AND INSTALL SEALANT AT VERTICAL INSET CORNER JOINT
IN CMU BACKUP.
23 2122
+/-2'-4"
B
GLASS STRUCTURE
NOT IN SCOPE
J
NOT IN SCOPE.
PROTECT DURING THE WORK.
E
ALT.
PROTECT EXISTING SOLARIUM. DO NOT DAMAGE
EXISTING SOLARIUM FRAMING AT BRICK MASONRY
EXTERIOR WALL DURING THE WORK. REMOVE EXISTING
SURFACE-MOUNTED FASTENERS, AS REQUIRED TO
COMPLETE THE WORK. REPLACE FASTENERS WITH NEW
S.S. FASTENERS TO MATCH EXISTING. INSTALL NEW
BACKER ROD AND SEALANT AT JOINT BETWEEN
SOLARIUM FRAME AND NEW BRICK MASONRY VENEER.
A300
TYP.
SEE 2/A200 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 1.
A301 TYP.
A301 TYP.
NO WORK AT EXTERIOR
WALLS WITHIN SOLARIUM.
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
EXTERIOR ELEVATIONS - 3 AND 1 (NORTH) BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JR NL
100% BID DOCUMENTS
A200
SCALE: 1/8" = 1'-0"2 ELEVATIONS - 3 AND 1 (NORTH)
ELEVATION 3 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
3A3 8 0 3A4 7 0 3A5 18 6 3A6 20 2 3A7 22 0 3A8 20 0 3A9 26 0 3A10 18 0 3B3 9 0 3B4 7 4 3B5 6 0 3B6 13 0 3B7 7 0 3B8 15 0 3B9 24 0 3B10 20 0
Grand total: 16 240 12
ELEVATION 1 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
1A3 1 0 1A4 2 0 1A5 5 0 1A6 3 1 1A7 3 1 1A8 3 0 1A9 7 1 1A10 0 0
SCALE: 1/8" = 1'-0"1 ELEVATION 2 (WEST)
ELEVATION 1 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
1B3 5 0 1B4 2 0 1B5 0 1 1B6 1 0 1B7 4 0 1B8 0 0 1B9 1 0 1B10 2 0 1C3 6 0 1C4 5 0 1C5 6 0 1C6 7 0 1C7 8 0 1C8 8 0 1C9 8 0 1C10 2 0 1D3 5 0 1D4 6 1 1D5 6 0 1D6 8 0 1D7 10 1 1D8 20 1 1D9 6 1 1D10 5 0
Grand total: 32 155 8
SEE ADJACENT ELEVATION 1 SCHEDULE FOR GRAND TOTAL REPAIR QUANTITIES
ELEV. 83'-8"
LEVEL 02
ELEV. 97'-5 3/8"
A
LEVEL 03
ELEV. 111'-2 3/4"
LEVEL 04
ELEV. 122'-9 3/8"
LEVEL 05
ELEV. 134'-4"
LEVEL 06
ELEV. 145'-10 5/8"
LEVEL 07
ELEV. 157'-5 1/4"
LEVEL 08
ELEV. 168'-11 7/8"
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
BCEHK DJ
A
A
�EMERGENCY AMBULANCE ENTRY GARAGE AND SHED
ELEVATION 21 ELEVATION 19
12"-16" 12"-16"
EJEJ EJ EJ
CC
A
A
21C1
21A2 21B2
21A3 21B3
21A4 21B4
21A5 21B5
21A6 21B6
21A7 21B7
21A8 21B8
21A9 21B9
21A10 21B10
21D1
E NOT IN SCOPE
A302
�E
TYP.
INCLUDING EAST
SIDE OF CORNER
A301 TYP.
REMOVE EXISTING SEALANT AND
BACKING MATERIAL AND INSTALL
NEW BACKER ROD AND SEALANT AT
JOINT BETWEEN PRECAST CONCRETE
PANELS AND ROOF BASE FLASHING
PER 1/A303, TYP.
A300
TYP.
G
H
A301 TYP.
SYMBOLS LEGEND
TOP OF STEEL
ELEV. 10'-0"
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
ENLARGED PLAN OR
SECTION INDICATOR
ORIGINAL
WINDOWS
COLUMN LINE
ELEVATION
INDICATOR
TYPICAL
DIMENSIONING
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH ARROW
4'-4"
NORTH
A320
A 1.X
A 1.X
MATCH LINE
VIEW REFERENCE
1 View Name
SCALE: 1/8" = 1'-0"
A1.1
? KEYNOTE TAG
LOUVER
REMOVE AND REBUILD
BRICK MASONRY
EJ
EXISTING VERTICAL
EXPANSION JOINT IN
BRICK MASONRY VENEER
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
REFER TO SYMBOL LEGEND, GENERAL NOTES, KEYNOTES AND
DRAWINGS FOR EXTENT OF WORK
VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
PORTIONS OF EXISTING CONSTRUCTION MAY HAVE BEEN
MODIFIED BY OWNER.
MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN
THE BUILDING NOT AFFECTED BY THIS WORK. COORDINATE
WITH COR ANY DISRUPTION IN SERVICES REQUIRED TO
PERFORM WORK OR TO MODIFY EXISTING PIPING,
DUCTWORK OR ANY ASSOCIATED EQUIPMENT.
ANY ADJACENT SYSTEMS OR COMPONENTS DAMAGED
DURING THE WORK SHALL BE REMOVED COMPLETELY AND
REPLACED IN KIND AT NO COST TO THE OWNER.
KEY PLAN
N 21
KEYED NOTES
REMOVE 12"-16" WIDE SECTIONS OF EXISTING BRICK MASONRY
VENEER ADJACENT TO PRECAST CONCRETE PANEL EDGES FULL HEIGHT
OF THE EXTERIOR WALL. REMOVE BRICK MASONRY UNITS TO
MAINTAIN EXISTING RUNNING BOND TO ACCOMMODATE TOOTHING
IN REPLACEMENT BRICK MASONRY UNITS. INSTALL NEW THROUGH-
WALL FLASHING WITH END DAMS AT SHELF ANGLES AND VERTICAL
CAVITY CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE
PANELS. REBUILD VENEER WITH BRICK MASONRY SALVAGED FROM
ELEVATIONS 1, 23, AND 26 (PRIMARILY AT CENTER PANELS). SALVAGED
BRICK MASONRY UNITS ARE TO BE TOOTHED IN WITH EXISTING BRICK
MASONRY TO REMAIN. DO NOT SALVAGE/USE REMOVED BRICK
MASONRY UNITS WITH JOINT SEALANT RESIDUE PRESENT. SEE 2/A300,
TYP.
A
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS. INSTALL NEW THROUGH-WALL
FLASHING WITH END DAMS AT SHELF ANGLES, VERTICAL CAVITY
CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE PANELS,
AND FLUID-APPLIED AIR/MOISTURE BARRIER OVER EXISTING CMU
BACKUP. REBUILD VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, AND FINISH. SALVAGE EXISTING BRICK UNITS
WHERE POSSIBLE FOR USE AT OTHER REBUILD AREAS. SEE 1/A300, TYP.
AFTER COMPLETION OF MASONRY REPAIRS, CLEAN EXISTING
MASONRY AND APPLY CLEAR PENETRATING WATER REPELLENT OVER
EXTERIOR SURFACE OF ALL BRICK MASONRY WALL AREAS.
MARK NOTES
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS AND EXISTING VERTICAL
EXPANSION JOINTS AT THE CORNER FULL HEIGHT OF THE EXTERIOR
WALL. INSTALL NEW THROUGH-WALL FLASHING WITH END DAMS AT
SHELF ANGLES, VERTICAL CAVITY CLOSURE FLASHING AT INTERFACE
WITH PRECAST CONCRETE PANELS, AND FLUID-APPLIED AIR/MOISTURE
BARRIER OVER EXISTING CMU BACKUP. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE, COLOR, AND FINISH.
SALVAGE EXISTING BRICK UNITS WHERE POSSIBLE FOR USE AT OTHER
REBUILD AREAS. SEE 1/A300, TYP.
REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL AND
INSTALL NEW TWO-STAGE SEALANT JOINT AT PRECAST CONCRETE
FASCIA BAND AND WALL PANEL JOINTS PER 2/A303, TYP.
B
C
D
E
F
CLEAN EXISTING PRECAST CONCRETE PANELS TO REMOVE SURFACE
SOILING IN PREPARATION FOR CONCRETE REPAIR COLOR MATCHING.
CLEANING TRIALS AT A LOCATION SELECTED DURING CONSTRUCTION
WILL BE REQUIRED TO FINALIZE THE MOST EFFECTIVE CLEANING
APPROACH. AFTER CLEANING AND REPAIRS ARE COMPLETED, APPLY
CLEAR PENETRATING WATER REPELLENT OVER EXTERIOR SURFACE OF
ALL PANELS.
G
AT ALL PUNCHED OPENINGS WITH ORIGINAL WINDOWS OR LOUVERS
IN PLACE, REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL
AND INSTALL NEW BACKER ROD AND SEALANT PER 1/A303. TYP.
H
I
J
PERFORM ISOLATED REPAIRS AT CRACKS AND SPALLS IN PRECAST
CONCRETE PANELS. REPAIR LOCATIONS AND APPROXIMATE
QUANTITEIS ARE INDICATED IN THE TABLES ABOVE. SEE 8, 9, AND
10/A302, TYP.
ALTERNATE 1 - IN LIEU OF FULL DISASSEMBLY AND RECLADDING,
PERFORM REPAIRS PER KEYNOTE A ALONG THE PRECAST CONCRETE
PANEL EDGES PER 2/A300, TYP.
ALTERNATE 2 - IN LIEU OF EXTENDING EXTERIOR WALL REPAIRS
AROUND INSET CORNER TO PRECAST CONCRETE PANEL ON NEXT
ELEVATION PER 3/A300, TERMINATE REPAIRS AT INSET CORNER PER
2/A302, SIM. AND INSTALL SEALANT AT VERTICAL INSET CORNER JOINT
IN CMU BACKUP.
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
EXTERIOR ELEVATIONS - 21 (SOUTH) BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JR NL
100% BID DOCUMENTS
A201
SCALE: 1/8" = 1'-0"1 ELEVATION - 21 (SOUTH)
ELEVATION 21 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
21A2 3 0 21A3 16 0 21A4 13 2 21A5 16 1 21A6 13 0 21A7 24 0 21A8 16 0 21A9 20 0 21A10 26 0 21B2 26 0 21B3 26 1 21B4 20 0 21B5 16 1 21B6 24 0 21B7 26 6 21B8 5 0 21B9 10 0 21B10 24 0 21C1 6 0 21D1 0 0
Grand total: 20 330 11
ELEV. 83'-8"
LEVEL 02
ELEV. 97'-5 3/8"
LEVEL 03
ELEV. 111'-2 3/4"
LEVEL 04
ELEV. 122'-9 3/8"
LEVEL 05
ELEV. 134'-4"
LEVEL 06
ELEV. 145'-10 5/8"
LEVEL 07
ELEV. 157'-5 1/4"
LEVEL 08
ELEV. 168'-11 7/8"
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
KLN
MACHINE ROOM
ELEV. 217'-2 3/8"
TANK RM. FL./TOP OF P.H. ROOF
ELEV. 227'-2 3/8"
QSTUXZAA RV
T.O. ROOF SLAB
ELEV. 243'-5"
A
A
A
23A9 23B9 23C9 23D10 23E9 23F9 23G9 23H9 23I9 23J9 23K9 23L9 23M9
23N1023M1023L1023K1023J1023I1023H1023G1023E10 23F1023C10 23D1023A10 23B10
+/-6'-8" +/-6'-8" +/-6'-8" +/-6'-8" +/-6'-10" +/-4'-1"+/-6'-8"
B
N O
T
IN
S C
O
PE
EXISTING METAL PANEL EXTERIOR
SCREEN WALL AT MECHANICAL
PENTHOUSE TO REMAIN. PROTECT
DURING THE WORK.
E
N O
T
IN
S C
O
PE
REMOVE EXISTING SEALANT AND BACKING MATERIAL AND INSTALL
NEW BACKER ROD AND SEALANT AT JOINT BETWEEN PRECAST
CONCRETE PANELS AND ROOF BASE FLASHING PER 1/A303, TYP.
SEE 1/A202 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 24
A301 TYP.
A301 TYP.
SEE 1/A202 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 24
NO WORK AT EXTERIOR
WALLS WITHIN SOLARIUM
PROTECT EXISTING SOLARIUM DURING THE WORK AND
DO NOT DAMAGE SOLARIUM FRAME AT INTERFACE
WITH EXTERIOR WALLS. BRICK MASONRY REBUILD IS TO
EXTEND DOWN TO, BUT NOT BELOW EXISTING
SOLARIUM FRAME. INSTALL NEW THROUGH-WALL
FLASHING PER 4/A301, SIM. REMOVE EXISTING SEALANT
AT PERIMETER JOINT BETWEEN SOLARIUM FRAMING,
BRICK MASONRY VENEER, AND PRECAST CONCRETE
PANELS, AND INSTALL NEW BACKER ROD AND SEALANT
AFTER MASONRY REPAIRS ARE COMPLETE.
F
G H
SIM.
SYMBOLS LEGEND
TOP OF STEEL
ELEV. 10'-0"
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
ENLARGED PLAN OR
SECTION INDICATOR
ORIGINAL
WINDOWS
COLUMN LINE
ELEVATION
INDICATOR
TYPICAL
DIMENSIONING
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH ARROW
4'-4"
NORTH
A320
A 1.X
A 1.X
MATCH LINE
VIEW REFERENCE
1 View Name
SCALE: 1/8" = 1'-0"
A1.1
? KEYNOTE TAG
LOUVER
REMOVE AND REBUILD
BRICK MASONRY
EJ
EXISTING VERTICAL
EXPANSION JOINT IN
BRICK MASONRY VENEER
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
REFER TO SYMBOL LEGEND, GENERAL NOTES, KEYNOTES AND
DRAWINGS FOR EXTENT OF WORK
VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
PORTIONS OF EXISTING CONSTRUCTION MAY HAVE BEEN
MODIFIED BY OWNER.
MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN
THE BUILDING NOT AFFECTED BY THIS WORK. COORDINATE
WITH COR ANY DISRUPTION IN SERVICES REQUIRED TO
PERFORM WORK OR TO MODIFY EXISTING PIPING,
DUCTWORK OR ANY ASSOCIATED EQUIPMENT.
ANY ADJACENT SYSTEMS OR COMPONENTS DAMAGED
DURING THE WORK SHALL BE REMOVED COMPLETELY AND
REPLACED IN KIND AT NO COST TO THE OWNER.
KEY PLAN
N
�24 � 22
KEYED NOTES
REMOVE 12"-16" WIDE SECTIONS OF EXISTING BRICK MASONRY
VENEER ADJACENT TO PRECAST CONCRETE PANEL EDGES FULL HEIGHT
OF THE EXTERIOR WALL. REMOVE BRICK MASONRY UNITS TO
MAINTAIN EXISTING RUNNING BOND TO ACCOMMODATE TOOTHING
IN REPLACEMENT BRICK MASONRY UNITS. INSTALL NEW THROUGH-
WALL FLASHING WITH END DAMS AT SHELF ANGLES AND VERTICAL
CAVITY CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE
PANELS. REBUILD VENEER WITH BRICK MASONRY SALVAGED FROM
ELEVATIONS 1, 23, AND 26 (PRIMARILY AT CENTER PANELS). SALVAGED
BRICK MASONRY UNITS ARE TO BE TOOTHED IN WITH EXISTING BRICK
MASONRY TO REMAIN. DO NOT SALVAGE/USE REMOVED BRICK
MASONRY UNITS WITH JOINT SEALANT RESIDUE PRESENT. SEE 2/A300,
TYP.
A
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS. INSTALL NEW THROUGH-WALL
FLASHING WITH END DAMS AT SHELF ANGLES, VERTICAL CAVITY
CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE PANELS,
AND FLUID-APPLIED AIR/MOISTURE BARRIER OVER EXISTING CMU
BACKUP. REBUILD VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, AND FINISH. SALVAGE EXISTING BRICK UNITS
WHERE POSSIBLE FOR USE AT OTHER REBUILD AREAS. SEE 1/A300, TYP.
AFTER COMPLETION OF MASONRY REPAIRS, CLEAN EXISTING
MASONRY AND APPLY CLEAR PENETRATING WATER REPELLENT OVER
EXTERIOR SURFACE OF ALL BRICK MASONRY WALL AREAS.
MARK NOTES
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS AND EXISTING VERTICAL
EXPANSION JOINTS AT THE CORNER FULL HEIGHT OF THE EXTERIOR
WALL. INSTALL NEW THROUGH-WALL FLASHING WITH END DAMS AT
SHELF ANGLES, VERTICAL CAVITY CLOSURE FLASHING AT INTERFACE
WITH PRECAST CONCRETE PANELS, AND FLUID-APPLIED AIR/MOISTURE
BARRIER OVER EXISTING CMU BACKUP. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE, COLOR, AND FINISH.
SALVAGE EXISTING BRICK UNITS WHERE POSSIBLE FOR USE AT OTHER
REBUILD AREAS. SEE 1/A300, TYP.
REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL AND
INSTALL NEW TWO-STAGE SEALANT JOINT AT PRECAST CONCRETE
FASCIA BAND AND WALL PANEL JOINTS PER 2/A303, TYP.
B
C
D
E
F
CLEAN EXISTING PRECAST CONCRETE PANELS TO REMOVE SURFACE
SOILING IN PREPARATION FOR CONCRETE REPAIR COLOR MATCHING.
CLEANING TRIALS AT A LOCATION SELECTED DURING CONSTRUCTION
WILL BE REQUIRED TO FINALIZE THE MOST EFFECTIVE CLEANING
APPROACH. AFTER CLEANING AND REPAIRS ARE COMPLETED, APPLY
CLEAR PENETRATING WATER REPELLENT OVER EXTERIOR SURFACE OF
ALL PANELS.
G
AT ALL PUNCHED OPENINGS WITH ORIGINAL WINDOWS OR LOUVERS
IN PLACE, REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL
AND INSTALL NEW BACKER ROD AND SEALANT PER 1/A303. TYP.
H
I
J
PERFORM ISOLATED REPAIRS AT CRACKS AND SPALLS IN PRECAST
CONCRETE PANELS. REPAIR LOCATIONS AND APPROXIMATE
QUANTITEIS ARE INDICATED IN THE TABLES ABOVE. SEE 8, 9, AND
10/A302, TYP.
ALTERNATE 1 - IN LIEU OF FULL DISASSEMBLY AND RECLADDING,
PERFORM REPAIRS PER KEYNOTE A ALONG THE PRECAST CONCRETE
PANEL EDGES PER 2/A300, TYP.
ALTERNATE 2 - IN LIEU OF EXTENDING EXTERIOR WALL REPAIRS
AROUND INSET CORNER TO PRECAST CONCRETE PANEL ON NEXT
ELEVATION PER 3/A300, TERMINATE REPAIRS AT INSET CORNER PER
2/A302, SIM. AND INSTALL SEALANT AT VERTICAL INSET CORNER JOINT
IN CMU BACKUP.
11109 10a
+/-8"
B
+/-3'-8"
EJ
24K10
24K924J9
24J10
+/-2'-4"
+/-16'-0"
J
REMOVE EXISTING SEALANT AND BACKING
MATERIAL AND INSTALL NEW BACKER ROD
AND SEALANT AT JOINT BETWEEN PRECAST
CONCRETE PANELS AND ROOF BASE
FLASHING PER 1/A303, TYP.
SEE 3/A202 FOR ADJACENT
VENEER REBUILD AREA ON
ELEVATION 23
ALT.
A300
SIM.
A301 TYP.
E
G
H
F
D
A301 TYP.
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
10 9
10a
+/-8"
�J
+/-3'-8"
+/-16'-0"
EJ
22B1022A10
B
D
E A300
SIM.
SEE 3/A202 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 23
NO WORK AT EXTERIOR
WALLS WITHIN SOLARIUM
ALT.
F
G
H
+/-2'-4"
-1
1' -6
A301 TYP.
A301 TYP.SIM.
TYP.
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
EXTERIOR ELEVATIONS - 23 (SOUTH) BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JR NL
100% BID DOCUMENTS
A202
SCALE: 1/8" = 1'-0"3 ELEVATION - 23 (SOUTH)
ELEVATION 23 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
23A9 20 0 23A10 0 0 23B9 7 0 23B10 3 0 23C9 21 0 23C10 1 0 23D10 7 0 23D10 1 0 23E9 20 0 23E10 1 2 23F9 7 0 23F10 1 0 23G9 16 0 23G10 0 0 23H9 6 0 23H10 0 0 23I9 16 0 23I10 0 0 23J9 7 0 23J10 0 0 23K9 16 0 23K10 3 0 23L9 8 0 23L10 0 0 23M9 20 0 23M10 1 0 23N10 0 0 24J9 3 0 24J10 0 0 24K9 2 0 24K10 0 0
Grand total: 31 187 2
SCALE: 1/8" = 1'-0"1 ELEVATION 24 (WEST)
SCALE: 1/8" = 1'-0"2 ELEVATION 22 (EAST)
PROTECT EXISTING SOLARIUM DURING THE WORK AND DO NOT DAMAGE
SOLARIUM FRAME AT INTERFACE WITH EXTERIOR WALLS. BRICK MASONRY
REBUILD IS TO EXTEND DOWN TO BUT NOT BELOW EXISTING SOLARIUM
FRAME. INSTALL NEW THROUGH-WALL FLASHING STEPPED TO
ACCOMMODATE SLOPED GLAZING PER 4/A301, SIM. REMOVE EXISTING
SEALANT AT PERIMETER JOINT BETWEEN SOLARIUM FRAMING, BRICK
MASONRY VENEER, AND PRECAST CONCRETE PANELS, AND INSTALL NEW
BACKER ROD AND SEALANT AFTER MASONRY REPAIRS ARE COMPLETE.
ELEV. 83'-8"
LEVEL 02
ELEV. 97'-5 3/8"
LEVEL 03
ELEV. 111'-2 3/4"
LEVEL 04
ELEV. 122'-9 3/8"
LEVEL 05
ELEV. 134'-4"
LEVEL 06
ELEV. 145'-10 5/8"
LEVEL 07
ELEV. 157'-5 1/4"
LEVEL 08
ELEV. 168'-11 7/8"
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
AACCFFGGHHJJKKLL
A
25C2
25C3
25C4
25C5
25C6
25C7
25C8
25C9
25C10
25D2
25D3
25D4
25D5
25D6
25D7
25D8
25D9
25D10
25C1 25D125A1 25B1 25E1 25F1
ELEVATION 25ELEVATION 27
12"-16"12"-16"
EJEJEJEJ
A
A
C
E
NOT IN SCOPE
A300
�E
A301 TYP.
TYP.
A301 TYP.
F
G
H
�C
SYMBOLS LEGEND
TOP OF STEEL
ELEV. 10'-0"
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
ENLARGED PLAN OR
SECTION INDICATOR
ORIGINAL
WINDOWS
COLUMN LINE
ELEVATION
INDICATOR
TYPICAL
DIMENSIONING
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH ARROW
4'-4"
NORTH
A320
A 1.X
A 1.X
MATCH LINE
VIEW REFERENCE
1 View Name
SCALE: 1/8" = 1'-0"
A1.1
? KEYNOTE TAG
LOUVER
REMOVE AND REBUILD
BRICK MASONRY
EJ
EXISTING VERTICAL
EXPANSION JOINT IN
BRICK MASONRY VENEER
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
REFER TO SYMBOL LEGEND, GENERAL NOTES, KEYNOTES AND
DRAWINGS FOR EXTENT OF WORK
VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
PORTIONS OF EXISTING CONSTRUCTION MAY HAVE BEEN
MODIFIED BY OWNER.
MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN
THE BUILDING NOT AFFECTED BY THIS WORK. COORDINATE
WITH COR ANY DISRUPTION IN SERVICES REQUIRED TO
PERFORM WORK OR TO MODIFY EXISTING PIPING,
DUCTWORK OR ANY ASSOCIATED EQUIPMENT.
ANY ADJACENT SYSTEMS OR COMPONENTS DAMAGED
DURING THE WORK SHALL BE REMOVED COMPLETELY AND
REPLACED IN KIND AT NO COST TO THE OWNER.
KEY PLAN
N
KEYED NOTES
REMOVE 12"-16" WIDE SECTIONS OF EXISTING BRICK MASONRY
VENEER ADJACENT TO PRECAST CONCRETE PANEL EDGES FULL HEIGHT
OF THE EXTERIOR WALL. REMOVE BRICK MASONRY UNITS TO
MAINTAIN EXISTING RUNNING BOND TO ACCOMMODATE TOOTHING
IN REPLACEMENT BRICK MASONRY UNITS. INSTALL NEW THROUGH-
WALL FLASHING WITH END DAMS AT SHELF ANGLES AND VERTICAL
CAVITY CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE
PANELS. REBUILD VENEER WITH BRICK MASONRY SALVAGED FROM
ELEVATIONS 1, 23, AND 26 (PRIMARILY AT CENTER PANELS). SALVAGED
BRICK MASONRY UNITS ARE TO BE TOOTHED IN WITH EXISTING BRICK
MASONRY TO REMAIN. DO NOT SALVAGE/USE REMOVED BRICK
MASONRY UNITS WITH JOINT SEALANT RESIDUE PRESENT. SEE 2/A300,
TYP.
A
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS. INSTALL NEW THROUGH-WALL
FLASHING WITH END DAMS AT SHELF ANGLES, VERTICAL CAVITY
CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE PANELS,
AND FLUID-APPLIED AIR/MOISTURE BARRIER OVER EXISTING CMU
BACKUP. REBUILD VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, AND FINISH. SALVAGE EXISTING BRICK UNITS
WHERE POSSIBLE FOR USE AT OTHER REBUILD AREAS. SEE 1/A300, TYP.
AFTER COMPLETION OF MASONRY REPAIRS, CLEAN EXISTING
MASONRY AND APPLY CLEAR PENETRATING WATER REPELLENT OVER
EXTERIOR SURFACE OF ALL BRICK MASONRY WALL AREAS.
MARK NOTES
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS AND EXISTING VERTICAL
EXPANSION JOINTS AT THE CORNER FULL HEIGHT OF THE EXTERIOR
WALL. INSTALL NEW THROUGH-WALL FLASHING WITH END DAMS AT
SHELF ANGLES, VERTICAL CAVITY CLOSURE FLASHING AT INTERFACE
WITH PRECAST CONCRETE PANELS, AND FLUID-APPLIED AIR/MOISTURE
BARRIER OVER EXISTING CMU BACKUP. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE, COLOR, AND FINISH.
SALVAGE EXISTING BRICK UNITS WHERE POSSIBLE FOR USE AT OTHER
REBUILD AREAS. SEE 1/A300, TYP.
REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL AND
INSTALL NEW TWO-STAGE SEALANT JOINT AT PRECAST CONCRETE
FASCIA BAND AND WALL PANEL JOINTS PER 2/A303, TYP.
B
C
D
E
F
CLEAN EXISTING PRECAST CONCRETE PANELS TO REMOVE SURFACE
SOILING IN PREPARATION FOR CONCRETE REPAIR COLOR MATCHING.
CLEANING TRIALS AT A LOCATION SELECTED DURING CONSTRUCTION
WILL BE REQUIRED TO FINALIZE THE MOST EFFECTIVE CLEANING
APPROACH. AFTER CLEANING AND REPAIRS ARE COMPLETED, APPLY
CLEAR PENETRATING WATER REPELLENT OVER EXTERIOR SURFACE OF
ALL PANELS.
G
AT ALL PUNCHED OPENINGS WITH ORIGINAL WINDOWS OR LOUVERS
IN PLACE, REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL
AND INSTALL NEW BACKER ROD AND SEALANT PER 1/A303. TYP.
H
I
J
PERFORM ISOLATED REPAIRS AT CRACKS AND SPALLS IN PRECAST
CONCRETE PANELS. REPAIR LOCATIONS AND APPROXIMATE
QUANTITEIS ARE INDICATED IN THE TABLES ABOVE. SEE 8, 9, AND
10/A302, TYP.
ALTERNATE 1 - IN LIEU OF FULL DISASSEMBLY AND RECLADDING,
PERFORM REPAIRS PER KEYNOTE A ALONG THE PRECAST CONCRETE
PANEL EDGES PER 2/A300, TYP.
ALTERNATE 2 - IN LIEU OF EXTENDING EXTERIOR WALL REPAIRS
AROUND INSET CORNER TO PRECAST CONCRETE PANEL ON NEXT
ELEVATION PER 3/A300, TERMINATE REPAIRS AT INSET CORNER PER
2/A302, SIM. AND INSTALL SEALANT AT VERTICAL INSET CORNER JOINT
IN CMU BACKUP.
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
EXTERIOR ELEVATIONS - 25 (SOUTH) BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JR NL
100% BID DOCUMENTS
A203
SCALE: 1/8" = 1'-0"1 ELEVATION - 25 (SOUTH)
ELEVATION 25 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
25A1 13 0 25B1 13 0 25C1 7 0 25C2 2 1 25C3 0 1 25C4 2 0 25C5 3 2 25C6 3 0 25C7 5 0 25C8 7 0 25C9 6 0 25C10 8 0 25D1 3 0 25D2 5 0 25D3 5 1 25D4 2 0 25D5 17 0 25D6 3 0 25D7 6 0 25D8 12 0 25D9 13 0 25D10 2 0 25E1 10 0 25F1 6 0
Grand total: 24 153 5
ELEV. 83'-8"
LEVEL 02
ELEV. 97'-5 3/8"
LEVEL 03
ELEV. 111'-2 3/4"
LEVEL 04
ELEV. 122'-9 3/8"
LEVEL 05
ELEV. 134'-4"
LEVEL 06
ELEV. 145'-10 5/8"
LEVEL 07
ELEV. 157'-5 1/4"
LEVEL 08
ELEV. 168'-11 7/8"
LEVEL 09
ELEV. 180'-6 1/2"
LEVEL 10
ELEV. 192'-1 1/8"
P.H. FL. & TOP OF ROOF SLAB
ELEV. 203'-7 3/4"
8 7 6 5 4 2 13
26F2
26F3
26F4
26F5
26F6
26F7
26F8
26F9
26F10
26E2
26E3
26E4
26E5
26E6
26E7
26E8
26E9
26E10
26B2
26B3
26B4
26B5
26B6
26B7
26B8
26B9
26B10
26A2
26A3
26A4
26A5
26A6
26A7
26A8
26A9
26A10
26C126B1 26D1
+/-2'-1"
26E1 26F1
+/-3'-8" +/-3'-8"
EJ
B
D
E
NOT IN SCOPENOT IN SCOPE
+/-19'-0"
I
I
EMERGENCY EXIT
A302
+/-3'-5"
B
J
ALT.
2ND FLOOR ROOF
ACCESS DOOR
ALT.
ALT.
REMOVE EXISTING SEALANT AND
BACKING MATERIAL AND INSTALL
NEW BACKER ROD AND SEALANT
AT JOINT BETWEEN PRECAST
CONCRETE PANELS AND ROOF
BASE FLASHING PER 1/A303, TYP.
A301 TYP.
TYP.
�E
A301 TYP.
SIM.
A300
TYP.
SEE 1/A204 FOR ADJACENT VENEER
REBUILD AREA ON ELEVATION 27
F
G
H
A301 TYP.
EJ
A300
SYMBOLS LEGEND
TOP OF STEEL
ELEV. 10'-0"
ELEVATION INDICATION
SHEET NO.
ELEVATION NUMBER
ENLARGED PLAN OR
SECTION INDICATOR
ORIGINAL
WINDOWS
COLUMN LINE
ELEVATION
INDICATOR
TYPICAL
DIMENSIONING
TYPICAL TITLE FOR
SECTIONS & DETAILS
NORTH ARROW
4'-4"
NORTH
A320
A 1.X
A 1.X
MATCH LINE
VIEW REFERENCE
1 View Name
SCALE: 1/8" = 1'-0"
A1.1
? KEYNOTE TAG
LOUVER
REMOVE AND REBUILD
BRICK MASONRY
EJ
EXISTING VERTICAL
EXPANSION JOINT IN
BRICK MASONRY VENEER
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
REFER TO SYMBOL LEGEND, GENERAL NOTES, KEYNOTES AND
DRAWINGS FOR EXTENT OF WORK
VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
PORTIONS OF EXISTING CONSTRUCTION MAY HAVE BEEN
MODIFIED BY OWNER.
MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN
THE BUILDING NOT AFFECTED BY THIS WORK. COORDINATE
WITH COR ANY DISRUPTION IN SERVICES REQUIRED TO
PERFORM WORK OR TO MODIFY EXISTING PIPING,
DUCTWORK OR ANY ASSOCIATED EQUIPMENT.
ANY ADJACENT SYSTEMS OR COMPONENTS DAMAGED
DURING THE WORK SHALL BE REMOVED COMPLETELY AND
REPLACED IN KIND AT NO COST TO THE OWNER.
KEY PLAN
N
�26
�27
KEYED NOTES
REMOVE 12"-16" WIDE SECTIONS OF EXISTING BRICK MASONRY
VENEER ADJACENT TO PRECAST CONCRETE PANEL EDGES FULL HEIGHT
OF THE EXTERIOR WALL. REMOVE BRICK MASONRY UNITS TO
MAINTAIN EXISTING RUNNING BOND TO ACCOMMODATE TOOTHING
IN REPLACEMENT BRICK MASONRY UNITS. INSTALL NEW THROUGH-
WALL FLASHING WITH END DAMS AT SHELF ANGLES AND VERTICAL
CAVITY CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE
PANELS. REBUILD VENEER WITH BRICK MASONRY SALVAGED FROM
ELEVATIONS 1, 23, AND 26 (PRIMARILY AT CENTER PANELS). SALVAGED
BRICK MASONRY UNITS ARE TO BE TOOTHED IN WITH EXISTING BRICK
MASONRY TO REMAIN. DO NOT SALVAGE/USE REMOVED BRICK
MASONRY UNITS WITH JOINT SEALANT RESIDUE PRESENT. SEE 2/A300,
TYP.
A
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS. INSTALL NEW THROUGH-WALL
FLASHING WITH END DAMS AT SHELF ANGLES, VERTICAL CAVITY
CLOSURE FLASHING AT INTERFACE WITH PRECAST CONCRETE PANELS,
AND FLUID-APPLIED AIR/MOISTURE BARRIER OVER EXISTING CMU
BACKUP. REBUILD VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, AND FINISH. SALVAGE EXISTING BRICK UNITS
WHERE POSSIBLE FOR USE AT OTHER REBUILD AREAS. SEE 1/A300, TYP.
AFTER COMPLETION OF MASONRY REPAIRS, CLEAN EXISTING
MASONRY AND APPLY CLEAR PENETRATING WATER REPELLENT OVER
EXTERIOR SURFACE OF ALL BRICK MASONRY WALL AREAS.
MARK NOTES
REMOVE EXISTING BRICK MASONRY VENEER AT FULL WALL AREAS
BETWEEN PRECAST CONCRETE PANELS AND EXISTING VERTICAL
EXPANSION JOINTS AT THE CORNER FULL HEIGHT OF THE EXTERIOR
WALL. INSTALL NEW THROUGH-WALL FLASHING WITH END DAMS AT
SHELF ANGLES, VERTICAL CAVITY CLOSURE FLASHING AT INTERFACE
WITH PRECAST CONCRETE PANELS, AND FLUID-APPLIED AIR/MOISTURE
BARRIER OVER EXISTING CMU BACKUP. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE, COLOR, AND FINISH.
SALVAGE EXISTING BRICK UNITS WHERE POSSIBLE FOR USE AT OTHER
REBUILD AREAS. SEE 1/A300, TYP.
REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL AND
INSTALL NEW TWO-STAGE SEALANT JOINT AT PRECAST CONCRETE
FASCIA BAND AND WALL PANEL JOINTS PER 2/A303, TYP.
B
C
D
E
F
CLEAN EXISTING PRECAST CONCRETE PANELS TO REMOVE SURFACE
SOILING IN PREPARATION FOR CONCRETE REPAIR COLOR MATCHING.
CLEANING TRIALS AT A LOCATION SELECTED DURING CONSTRUCTION
WILL BE REQUIRED TO FINALIZE THE MOST EFFECTIVE CLEANING
APPROACH. AFTER CLEANING AND REPAIRS ARE COMPLETED, APPLY
CLEAR PENETRATING WATER REPELLENT OVER EXTERIOR SURFACE OF
ALL PANELS.
G
AT ALL PUNCHED OPENINGS WITH ORIGINAL WINDOWS OR LOUVERS
IN PLACE, REMOVE EXISTING SEALANT AND JOINT BACKING MATERIAL
AND INSTALL NEW BACKER ROD AND SEALANT PER 1/A303. TYP.
H
I
J
PERFORM ISOLATED REPAIRS AT CRACKS AND SPALLS IN PRECAST
CONCRETE PANELS. REPAIR LOCATIONS AND APPROXIMATE
QUANTITEIS ARE INDICATED IN THE TABLES ABOVE. SEE 8, 9, AND
10/A302, TYP.
ALTERNATE 1 - IN LIEU OF FULL DISASSEMBLY AND RECLADDING,
PERFORM REPAIRS PER KEYNOTE A ALONG THE PRECAST CONCRETE
PANEL EDGES PER 2/A300, TYP.
ALTERNATE 2 - IN LIEU OF EXTENDING EXTERIOR WALL REPAIRS
AROUND INSET CORNER TO PRECAST CONCRETE PANEL ON NEXT
ELEVATION PER 3/A300, TERMINATE REPAIRS AT INSET CORNER PER
2/A302, SIM. AND INSTALL SEALANT AT VERTICAL INSET CORNER JOINT
IN CMU BACKUP.
JJKK
+/- 1'-8"
J
NOT IN SCOPE
B
ALT.
E
A300
TYP.
A301 TYP.
SEE 2/A204 FOR
ADJACENT VENEER
REBUILD AREA ON
ELEVATION 26
A301 TYP.
J
B
ALT.
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
EXTERIOR ELEVATIONS - 26 (WEST) BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 JR NL
100% BID DOCUMENTS
A204
SCALE: 1/8" = 1'-0"2 ELEVATION - 26 (WEST)
ELEVATION 26 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
2 0 0 3 0 0
26A2 0 2 26A3 1 2 26A4 4 0 26A5 3 0 26A6 0 0 26A7 0 0 26A8 2 0 26A9 2 0 26A10 0 0 26B1 0 0 26B2 3 0 26B3 4 0 26B4 2 0 26B5 8 0 26B6 2 0 26B7 2 0 26B8 4 0 26B9 1 0 26B10 2 0
SCALE: 1/8" = 1'-0"1 ELEVATION 27 (SOUTH)
ELEVATION 26 - REPAIR QUANTITIES
PANEL DESIGNATION Crack (LF) Spall (SF)
26C1 0 0 26D1 0 0 26E1 13 0 26E2 4 0 26E3 2 0 26E4 4 0 26E5 2 0 26E6 4 0 26E7 3 0 26E8 13 6 26E9 4 0 26E10 3 0 26F1 3 0 26F2 0 0 26F3 2 3 26F4 0 2 26F5 2 0 26F6 3 0 26F7 4 5 26F8 3 0 26F9 16 0 26F10 1 2
Grand total: 43 126 22SEE ADJACENT ELEVATION 26 SCHEDULE FOR GRAND TOTAL REPAIR QUANTITIES
Project Number:
Building Number:
Drawing Number:
Project Title:
Location:
Issue Date: Checked: Drawn:
Drawing Title:
Approved: Project Director
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase:DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Sprinkler:
600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com
2850 Eisenhower Ave, Suite 310 Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com
ENLARGED ELEVATIONS BUILDING 111 FACADE REPAIR
5000 W NATIONAL AVE, MILWAUKEE, WI, 53295
695-22-121
MARCH 16, 2026 NH NL
100% BID DOCUMENTS
A300 Revisions: Date:
ENLARGED PARTIAL ELEVATION - SINGLE TIER PANEL WITH PUNCHED OPENING (AT FIELD OF WALL)
SCALE: 1/2'' = 1'-0''1
ENLARGED ELEVATION - FOUR TIER PANEL WITH PUNCHED OPENING (AT FIELD OF WALL)
SCALE: 1/2'' = 1'-0''2
TYPICAL PANEL
PARTIAL ELEVATION
4'-8" ±
TYPICAL PANEL WIDTH
VARIES VARIES
PHOTO REFERENCE - SINGLE TIER PANEL WITH PUNCHED OPENING (AT INSET CORNER)
SCALE: N.T.S.3
WALL AREAS BEYOND PRECAST PANEL TO BRICK MASONRY
WALL JOINT (SHOWN SHADED AND HATCHED) NOT IN SCOPE
EJ
EJ
BID DEDUCT: EXTENT OF REPAIRS TO
END AT VERTICAL EXPANSION JOINT AT
INSET CORNER, IN LIEU OF WRAPPING
AROUND THE CORNER AND EXTENDING
ONTO THE ADJACENT ELEVATION.
A301
A301
REMOVE EXISTING SEALANT AT HORIZONTAL
JOINTS BETWEEN PRECAST CONCRETE PANELS
AT SHELF ANGLES. SAWCUT PRECAST CONCRETE
AT EXISTING JOINT, AS REQUIRED, TO PROVIDE
1/2" MIN. CLEAR WIDTH, PER 3/A302. INSTALL
NEW BACKER ROD AND TWO-STAGE SEALANT
JOINT, PER 2/A303, TYP.
REMOVE EXISTING SEALANT AND INSTALL NEW
BACKER ROD AND SEALANT AT WINDOW
PERIMETER JOINTS AT ORIGINAL WINDOWS ONLY
WITHIN THE DESIGNATED WORK AREAS, TYP. SEE
1&2/A303 FOR SEALANT INSTALLATION. SEE
ELEVATIONS FOR ORIGINAL WINDOW LOCATIONS
TO BE INCLUDED IN THE SCOPE OF WORK.
REMOVE BRICK MASONRY VENEER AT BOTH SIDES
OF THE SINGLE TIER PRECAST CONCRETE PANELS
TO EXPOSE THE CMU BACKUP AND SHELF ANGLE
AT FLOOR LINES. INSTALL NEW FLUID-APPLIED WRB
OVER CMU BACKUP, THROUGH-WALL FLASHING
AT SHELF ANGLES, AND CAVITY CLOSURE ANGLE
AND SELF-ADHERING MEMBRANE FLASHING AT
INTERFACE BETWEEN EXTERIOR BRICK MASONRY
WALLS AND PRECAST CONCRETE PANELS.
SALVAGE, CLEAN, AND STORE EXISTING, INTACT
BRICK MASONRY UNITS FOR REINSTALLATION AT
OTHER LOCATIONS. REBUILD VENEER WITH NEW
BRICK MASONRY TO MATCH EXISTING SIZE,
COLOR, TEXTURE, AND FINISH. PROVIDE NEW S.S.
LATERAL TIES PER 8/A303, TYP. SEE SHEET A301
AND ELEVATION SHEETS FOR EXTENT OF REPAIRS.
A302
A302
TYP. TYP.
TYP.
TYP.
A302
TYP.
AT ALL SHELF ANGLES ADJACENT
TO THE PRECAST CONCRETE
PANELS (SHOWN SHADED), SEAL
ALL VOIDS AND BREACHES IN THE
EXISTING FLASHING MEMBRANE
PRIOR TO INSTALLATION OF NEW
WRB AND FLASHINGS.
AT ALL SHELF ANGLES ADJACENT TO
THE PRECAST CONCRETE PANELS
(SHOWN SHADED), ENSURE ALL VOIDS
AND BREACHES IN THE EXISTING
FLASHING MEMBRANE ARE SEALED
WITH NEW SELF-ADHERING
MEMBRANE PRIOR TO INSTALLATION
OF NEW WRB AND FLASHINGS.
3'-8" ±
TYPICAL WINDOW WIDTH
A302
TYP.
AT BRICK MASONRY WALL AREAS
NOT INCLUDED IN THE REBUILD
SCOPE OF WORK AND ALL
PRECAST CONCRETE PANELS,
PERFORM LIGHT-DUTY CLEANING
TO REMOVE SURFACE RESIDUE
AND APPLY CLEAR-PENETRATING
WATER REPELLENT, TYP. PROVIDE
PROTECTION FOR THE ADJACENT
FACADE ELEMENTS AND SYSTEMS,
AS REQUIRED. CLEANING IS TO BE
PERFORMED PER THE WATER
REPELLENT MANUFACTURER'S
RECOMMENDATIONS.
EXISTING VERTICAL EXPANSION
JOINT (EJ) IN BRICK MASONRY
VENEER. REMOVE EXISTING SEALANT
AND BACKING MATERIAL. INSTALL
NEW BACKER ROD AND SEALANT
AFTER BRICK MASONRY REBUILD IS
COMPLETE. SEE 2/A302, TYP.
EJ
EJ
PERFORM ABATEMENT, PER
SHEETS HA200 THROUGH
HA204, TO REMOVE
EXISTING SEALANT AT
VERTICAL JOINT BETWEEN
PRECAST CONCRETE PANELS
AND BRICK MASONRY WALL
AREAS PRIOR TO
DEMOLITION OF THE
EXISTING BRICK MASONRY.
INSTALL NEW BACKER ROD
AND SEALANT ALONG THE
FULL HEIGHT OF THE JOINT,
PER 1/A303, TYP., AFTER THE
INSTALLATION OF THE
FLASHING REPAIRS AND
BRICK MASONRY REBUILD.
PERFORM ABATEMENT, PER SHEETS
HA200 THROUGH HA204, TO
REMOVE EXISTING SEALANT AT
VERTICAL JOINT BETWEEN
PRECAST CONCRETE PANELS AND
BRICK MASONRY WALL AREAS
PRIOR TO DEMOLITION OF THE
EXISTING BRICK MASONRY.
INSTALL NEW BACKER ROD AND
SEALANT ALONG THE FULL HEIGHT
OF THE JOINT, PER 1/A303, TYP.
AFTER THE INSTALLATION OF THE
FLASHING REPAIRS AND BRICK
MASONRY REBUILD.
AT BRICK MASONRY WALL AREAS NOT INCLUDED
IN THE REBUILD SCOPE OF WORK AND ALL
PRECAST CONCRETE PANELS, PERFORM
LIGHT-DUTY CLEANING TO REMOVE SURFACE
RESIDUE AND APPLY CLEAR-PENETRATING WATER
REPELLENT, TYP. PROVIDE PROTECTION FOR THE
ADJACENT FACADE ELEMENTS AND SYSTEMS, AS
REQUIRED. CLEANING IS TO BE PERFORMED PER
THE WATER REPELLENT MANUFACTURER'S
RECOMMENDATIONS.
EXISTING VERTICAL EXPANSION JOINT (EJ) IN BRICK
MASONRY VENEER. REMOVE EXISTING SEALANT
AND BACKING MATERIAL. INSTALL NEW BACKER
ROD AND SEALANT AFTER BRICK MASONRY
REBUILD IS COMPLETE. SEE 2/A302, TYP.
PERFORM ISOLATED REPAIRS AT
CRACKS AND SPALLS IN THE PRECAST
CONCRETE PANELS. SEE PANEL REPAIR
NOTE BELOW PHOTO REFERENCE AND
THE REPAIR SCHEDULE ON THE
ELEVATION SHEETS FOR DESIGNATED
REPAIR LOCATIONS, TYPES, AND
QUANTITIES.
NOTE: PARTIAL ELEVATION DETAIL IS APPLICABLE TO ELEVATIONS 3, 21, AND
25. THIS REPAIR APPROACH IS ALSO APPLICABLE TO ALTERNATE NO. 1 AT THE
CENTRAL BRICK MASONRY WALL AT ELEVATION 26.
NOTE: PARTIAL ELEVATION IS APPLICABLE TO ELEVATIONS 1, 23, AND 26 AS WELL
AS THE WALL AREA ADJACENT TO THE INSET CORNER AT ELEVATIONS 2 AND 27,
AND WALL AREAS ABOVE THE LEVEL 9 ROOF AT ELEVATIONS 22 AND 24. SEE
3/A300 FOR PHOTO REFERENCE AT INSET CORNER.
A301
A301
REMOVE EXISTING SEALANT AT HORIZONTAL JOINTS
BETWEEN PRECAST CONCRETE PANELS AT SHELF
ANGLES. SAWCUT PRECAST CONCRETE AT EXISTING
JOINT, AS REQUIRED, TO PROVIDE 1/2" MIN. CLEAR
WIDTH, PER 3/A302. INSTALL NEW BACKER ROD AND
TWO-STAGE SEALANT JOINT, PER 2/A303, TYP.
PERFORM ABATEMENT, PER SHEETS HA200 THROUGH
HA204, TO REMOVE EXISTING SEALANT AT VERTICAL
JOINT BETWEEN PRECAST CONCRETE PANELS AND
BRICK MASONRY WALL AREAS PRIOR TO DEMOLITION
OF THE EXISTING BRICK MASONRY. INSTALL NEW
BACKER ROD AND SEALANT ALONG THE FULL HEIGHT
OF THE JOINT, PER 1/A303, TYP., AFTER THE
INSTALLATION OF THE FLASHING REPAIRS AND BRICK
MASONRY REBUILD.
REMOVE EXISTING SEALANT AND INSTALL NEW BACKER
ROD AND SEALANT AT WINDOW PERIMETER JOINTS AT
ORIGINAL WINDOWS ONLY WITHIN THE DESIGNATED
WORK AREAS, TYP. SEE 1&2/A303 FOR SEALANT
INSTALLATION. SEE ELEVATIONS FOR ORIGINAL
WINDOW LOCATIONS TO BE INCLUDED IN THE SCOPE
OF WORK.
REMOVE BRICK MASONRY VENEER AT BOTH SIDES OF
THE SINGLE TIER PRECAST CONCRETE PANELS TO
EXPOSE THE CMU BACKUP AND SHELF ANGLE AT
FLOOR LINES. INSTALL NEW FLUID-APPLIED WRB OVER
CMU BACKUP, THROUGH-WALL FLASHING AT SHELF
ANGLES, AND CAVITY CLOSURE ANGLE. INSTALL
SELF-ADHERING MEMBRANE FLASHING AT INTERFACE
BETWEEN EXTERIOR BRICK MASONRY WALLS AND
PRECAST CONCRETE PANELS. SALVAGE, CLEAN, AND
STORE EXISTING, INTACT BRICK MASONRY UNITS FOR
REINSTALLATION AT OTHER LOCATIONS. REBUILD
VENEER WITH NEW BRICK MASONRY TO MATCH
EXISTING SIZE, COLOR, TEXTURE, AND FINISH. PROVIDE
NEW S.S. LATERAL TIES PER 8/A303, TYP. SEE SHEET A301
AND ELEVATION SHEETS FOR EXTENT OF REPAIRS.
AT BRICK MASONRY WALL AREAS
NOT INCLUDED IN THE REBUILD
SCOPE OF WORK AND ALL
PRECAST CONCRETE PANELS,
PERFORM LIGHT-DUTY CLEANING
TO REMOVE SURFACE RESIDUE
AND APPLY CLEAR-PENETRATING
WATER REPELLENT, TYP. PROVIDE
PROTECTION FOR THE ADJACENT
FACADE ELEMENTS AND SYSTEMS,
AS REQUIRED. CLEANING IS TO BE
PERFORMED PER THE WATER
REPELLENT MANUFACTURER'S
RECOMMENDATIONS.
A302
A302
TYP. TYP.
TYP.
TYP.
A302
TYP.
A302
TYP.
TYPICAL PANEL
PARTIAL ELEVATION
TYPICAL PANEL
PHOTO REFERENCE
TYPICAL PANEL
PHOTO REFERENCE
'-6
/8
TY
PI
C
A L
PA
N
EL
H
EI
G
HT
5' -9
TY
PI
C
A L
W
IN
D O
W H
EI
G
HT
REMOVE EXISTING SEALANT AT
VERTICAL JOINTS…
This is the start of the file's text. The full file is on GovTribe.