_S-10700-00000521_Add004.pdf
PDF 2 MB Posted
- Attached to
- MILL CREEK WAREHOUSE RACKING PROJECT
- Solicitation number
- S-10700-00000521
- Issued by
- Marion County, Oregon
About this file
This document is an Addendum to an Invitation to Bid (ITB) issued by the State of Oregon Department of Administrative Services for the MILL CREEK WAREHOUSE RACKING PROJECT. The addendum modifies the original project manual and drawings, including changes to the project completion dates, clarifications on the shelving specifications, and additional instructions for the contractor. The project involves the breakdown, removal, and reinstallation of a high bay steel storage rack system at a new location. The bid opening date is November 23, 2021. The project start date is 1 calendar day from the issuance of the Notice to Proceed, with a substantial completion date of 56 calendar days and a final completion date of 70 calendar days.
The addendum also provides details on the shelving configuration, including the width, height, and number of shelves, as well as requirements for the contractor to use existing components and provide necessary equipment. The project is located in Marion County and the City of Salem, Oregon. The contract opportunity is for a state and local government agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum002~2.pdf | ||
| AttachmentB_MC WAREHOUSE PERMIT_STAMPED.pdf | ||
| S-10700-00000521_NOITA.pdf | ||
| S-10700_00000521_Shelving_NVM.pdf | ||
| 00000521_Bid_Tab.xls | XLS spreadsheet | |
| AttachmentA_Storage Rack Anchorage Package.pdf | ||
| PrebidAttendees.pdf | ||
| 5255-0 Final.pdf | ||
| S-10700-00000521_Add001.pdf | ||
| S-10700-00000521_Add003.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM No: 004
STATE OF OREGON
DEPARTMENT OF ADMINISTRATIVE SERVICES
November 17, 2021
ITB NO: S-10700-00000521
PROJECT: MILL CREEK WAREHOUSE RACKING PROJECT
BID OPENING DATE: November 23, 2021 at 2 PM
This Solicitation Addendum is issued to the above referenced bid and forms a part of the contract documents and modifies the original Project Manual and Drawings, dated 28 Sept 2021. Except as changed by this Addendum, all terms, conditions, scope of work, plans, specification, requirements and deadlines in the original ITB and previous addenda remain unchanged.
This Solicitation Addendum must be acknowledged by inserting its number on the appropriate blank lines in Section H – Addenda Acknowledgement of the Invitation to Bid. Failure to do so may result in rejection of Bid.
Requests for clarification, requests for change, and protests of Solicitation Addendum provisions addressed in this Solicitation Addendum must be received by DAS by 2:00 PM (Pacific Time) on 11/18/2021, or they will not be considered. DAS will not consider requests or protests of matters not added to or modified by this Solicitation Addendum.
New language is indicated by bold print and underline, deleted language is indicated by brackets [ ].
Modification
Attachment B, Plans
Replaced in its entirety, as Attachment 1 to this Addendum 004.
(Revision Drawings – Architectural: A101, dated 16 November, 2021; Modifies the original Project Manual and Drawings, dated 28 Sept 2021)
DRAWINGS
Sheet A101
1. Clarify: No vertical rack spacers are required.
2. Add: Graphic representation of vertical beam at shelving section with note - “Install beams vertically as back stops above each level. At midpoint above the lower and middle shelves and immediately above the top shelf, typ.”
3. Add: Note - “Install existing bolt-to-frame upright post protectors to each exposed corner”
4. Clarify: Future shelving shown as dashed.
5. Change: Shelving at egress aisle to be 12’ wide at all pass under locations.
6. Delete: (2) Quadplex convenience outlets from wall opposite the electrical room.
7. Add: Note – “Dock lights to be ofoi”
8. Clarify: Forklift charging outlets are NEMA L16-30.
9. Clarify: Shelving is 44” wide, not 48” wide. Maintain the critical dimension of 44” minimum at egress aisles
(per code), and 12’-0” minimum at aisles where forklifts will go (for functionality).
10. Clarify: Future shelving (3 rows, 102 shelf units) are not in contract.
11. Add: General Note C: “Contractor shall leave all existing unused shelf beam, uprights, wire shelves, post protectors, and any other existing racking components not used for the mill creek project at the North Valley Complex warehouse. This includes both those in good condition or damaged”
12. Add: General Note D: “Contractor to provide all necessary equipment for the project. DAS will not loan equipment such as fork lifts and other required tools.”
2 Modification
C.1.1 PROJECT INFORMATION
PROJECT COMPLETION DATES:
Project Start Date [Insert #] 1 calendar day[s] from issuance of Notice to Proceed.
Substantial Completion [82] 56 calendar days from issuance of Notice to Proceed Final Completion [96] 70 calendar days from issuance of Notice to Proceed
For
Information Only
The structural calculations were based on the 12 foot long racks, since they had the greatest structural requirements, but they will also cover the 8 foot long racks and, as such, the 8 foot long racks will be treated the same in regards to installation.
End of Addendum 004
CIRC.
BREAK
RR
RR
OPEN OFFICE
8'4'6'
GFI
GFI
FES
SEE SK-1 FOR ANCHOR DETAIL
6' -0
'-0
7' -6
7'
-6
1'-0"
FIRST SHELF OMITTED
AT EGRESS AISLES,
SEE DRAWINGS.
C
LE
A R
7' -0
INSTALL BEAMS
VERTICALLY AS
BACKSTOPS ABOVE
EACH LEVEL. AT
MIDPOINT ABOVE THE
LOWER AND MIDDLE
SHELVES AND
IMMEDIATELY ABOVE
THE TOP SHELF, TYP.
A
LEGEND - CODE COMPLIANCE SYMBOLS
EGRESS PATH OF TRAVEL WITH TRAVEL WIDTH
REQUIRED (PROVIDE MINIMUM ILLUMINATION FOR
EXITING - REFER TO ELECTRICAL DRAWINGS).
COMMON PATH OF EGRESS TRAVEL
EXIT ACCESS DISTANCE
E.A. X'-XX" - (PER 1016.2)
C.P. X'-XX" - (PER 1014.3)
44"
BUILDING EXIT
LIGHTED EXIT SIGN - CEILING MOUNTED
FIRE EXTINGUISHER
ACCESSIBLE ENTRANCE
FE
1 2 3 4 5 6 7 8 9
A
B
C
D
NOT IN SCOPE
SIGNAGE:
CONTRASTING LETTERS,
MIN. 2" HIGH AND 3/8"
STROKE TO SAY:
"FIRE ACCESS DOOR, DO
NOT BLOCK
44" MIN
20' HIGH, 44" WIDE,
METAL SHELVING,
TYP. ALL
ELECTRICAL PANEL (E)
FIRE SPRINKLER RISER
AND CONTROL ROOM (E)
323'-3"
5'
-1 1"
FE
DOUBLE DUPLEX
OUTLET @ 36"" AFF
M A
IN
T
A
IN
4"
M
IN
IM
U
M
A
IS
LE
W
A Y
P E
R O
F C
S
E C
T
IO
N
5.
480V, 3PH, 30AMP
OUTLET FOR FORKLIFT
CHARGING. NEMA L16-30
FE
FE
FE
FE
E.A. 129' 0"
C.P. 0' 0"
PALLET STAGING
DOUBLE DUPLEX
OUTLET @ 5' AFF
TYPICAL OF ALL.
6"
SIGNAGE:
CONTRASTING LETTERS,
MIN. 2" HIGH AND 3/8"
STROKE TO SAY:
"FIRE ACCESS DOOR, DO
NOT BLOCK
SHELVING IN THE MIDDLE EGRESS
PATH HAS ONE SHELF AT 12' AFF.
PATHWAY TO REMAIN CLEAR FOR
EGRESS AND FORKLIFT TRAFFIC.
'-0
'-0
13'-4"
'-8
'-4
11'-4"12'-0"
'-6
PROVIDE HIGH
VISIBILITY PAINT, WITH
STAINLESS COLUMN
WRAP TO 48" ON ALL
EXPOSED COLUMNS AT
RACKS AND PALLET
STAGING TYP.
FE
FE
FUTURE SHELVING. 12' WIDE BY 20' TALL
WITH (2) SHELVES AT 7'6" AND 15' AFF,
TYP. OF 102. NOT IN CONTRACT.R 75'-0"
12'-0"
8'-0"
NOT IN SCOPE
303030
A101
INSTALL EXISTING BOLT-TO-FRAME
UPRIGHT POST PROTECTORS AT
EACH EXPOSED CORNER, TYP.
12'-0"8'-0" 8'-0"
12'-0"
'-0
M
IN
A
A
A
NOTE: DOCK LIGHTS TO BE OFOI
A
A
A
CHECKED BY:
ISSUE DATE:
PROJECT NO:
REVISIONS
S E
R A
A rc hi te ct s, I nc
C o p y ri g h t p ro te c te d
S e e D e s ig n A g re e m e n t.
F o r u s e o n t h is p ro je c t o n ly
U n a u th o ri z e d r e p ro d u c ti o n o f a n y p a rt o f th is m a te ri a l is p ro h ib it e d
ARCHITECTURE
URBAN DESIGN + PLANNING
INTERIOR DESIGN
PORTLAND|OAKLAND
SERADESIGN.COM
/1 /2
:5
:5
A
M
P E
R M
IT
S
E T
D E
P A
R T
M E
N T
O F
A D
M
IN
IS
T
R A
T
IV
E S
E R
V
IC
E S
M
IL
L
C R
E E
K W
A R
E H
O U
S E
S
E A
U M
S V
IL
L E
H W
Y S
A L E
M O
R
A101
CTT
028 SEPT 2021
2101021
FLOOR PLAN -
LEVEL 01
GENERAL NOTES - FLOOR PLAN
A. FLOOR PLAN KEYED NOTES APPLY TO A100 SERIES SHEETS. ALL KEYED NOTES MAY NOT
OCCUR ON THIS SHEET AND DO NOT APPLY TO ANY OTHER SHEETS EXCEPT THOSE
NOTED.
B. GRIDS ARE FOR REFERENCE ONLY. CONTRACTOR TO SET CONTROL POINTS FOR
LAYOUT.
C. CONTRACTOR SHALL LEAVE ALL EXISTING UNUSED SHELF BEAM, UPRIGHTS, WIRE
SHELVES, POST PROTECTORS, AND ANY OTHER EXISTING RACKING COMPONENTS NOT
USED FOR THE MILL CREEK PROJECT AT THE NORTH VALLEY COMPLEX WAREHOUSE.
THIS INCLUDES BOTH THOSE IN GOOD CONDITION OR DAMAGED.
D. CONTRACTOR TO PROVIDE ALL NECISSARY EQUIPMENT FOR THE PROJECT. DAS WILL NOT
LOAN EQUIPMENT SUCH AS FORK LIFTS AND OTHER REQUIRED TOOLS.
1/4" = 1'-0"
SHELVING SECTION
BUILDING NARRATIVE
THIS IS A HIGH BAY SHELVING PERMIT FOR AN EXISTING TENANT SPACE LOCATED IN SALEM, OREGON.
THE SHELVING WILL STORE EMERGENCY SUPPLIES FOR THE STATE OF OREGON DEPARTMENT OF
ADMINISTRATIVE SERVICES. MOST COMMODOTIES ARE IN BOXES SHRINK WRAPPED TO STANDARD PALLETS. THERE IS NO FORSEEN HAZARDOUS STORAGE, INCLUDING BUT NOT LIMITED TO FLAMMABLE
AND COMBUSTABLE LIQUIDS. COMMODITIES ARE MIXED COMMODITY CLASS III. THERE IS NO
MODIFICATION TO OCCUPANCY, EXISTING FIRE SPRINKLER, EGRESS LIGHTING, OR EGRESS PATHWAYS.
APPLICABLE BUILDING REGULATIONS
2019 OREGON STRUCTURAL SPECIALTY CODE (OSSC) BASED ON THE 2018 INTERNATIONAL BUILDING
CODE WITH OREGON AMENDMENTS
2019 OREGON FIRE CODE (OFC) BASED ON 2018 INTERNATIONAL FIRE CODE
2019 OREGON MECHANICAL SPECIALTY CODE (OMSC) BASED ON 2018 INTERNATIONAL MECHANICAL CODE
AND INTERNATIONAL FUEL GAS CODE
2021 OREGON PLUMBING SPECIALTY CODE (OPSC) BASED ON 2021 UNIFORM PLUMBING CODE
2021 OREGON ELECTRICAL SPECIALTY CODE (OESC) BASED ON 2020 NFPA 70 NATIONAL ELECTRIC CODE
2021 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC) BASED ON ASHRAIE
90.1-2019
2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) WITH OSSC CH 34 AMENDMENTS
BUILDING OCCUPANCY AND SEPARATIONS
APPLICABLE OCCUPANCY CLASSIFICATION GROUPS: B, S-1
OCCUPANCY SEPARATION (TABLE 508.4):
OCCUPANCY
B TO S-1
REQUIRED SEPARATION (NOTE IF SPRINKER SYSTEM PROVIDED PER 903.3.1.1)
NO SEPARATION REQUIREMENT
CHAPTER 3
BUILDING CONSTRUCTION
CONSTRUCTION TYPE: III-B
CHAPTER 5, 6 & 7
BUILDING HEIGHT (PER TABLE 504.3) 75'-00" 37'-00"
ALLOWABLE EXISTING
NUMBER OF STORIES (PER TABLE 504.4) 3 STORIES 1 STORIES
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (TABLE 601)
BUILDING ELEMENT TYPE - III-B
ALLOWABLE EXISTING
STRUCTURAL FRAME
BEARING WALLS - EXTERIOR
INTERIOR
NOTES: NO CHANGE TO EXISTING SHELL
0 HOUR
2 HOUR
0 HOUR
NONBEARING WALLS AND PARTITIONS - INTERIOR
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
0 HOUR
0 HOUR
0 HOUR
TYPE - III-B
0 HOUR
2 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
FIRE PROTECTION CHAPTER 9
AUTOMATIC SPRINKLER SYSTEM
STANDPIPE SYSTEM
FIRE ALARM SYSTEM
FIRE DETECTION SYSTEM
REQUIRED PROPOSED TYPE/CLASS
YES PER 903.2.9, 903.2.4** EXISTING ESFR NFPA 13
NOT REQUIRED NOT REQUIRED
YES PER 907 EXISTING EXISTING
YES PER 907.2.14 EXISTING EXISTING
*PROVIDE FIRE PROTECTION PER IFC 907.
FIRE EXTINGUISHERS: CLASS A/B/C/D PER OFC 906, MAX. DISTANCE 75 FEET MOUNTED NOT MORE THAN 5
FEET AFF FOR EXTINQUISHERS UNDER 40 LBS, AND 3.5 FEET AFF FOR 40 LBS AND OVER.
1 EXTINGUISHER REQUIRED PER 11,250 SF (OFC 3206.11 AND 5704.3.3.1)
N/A
**PER OFC SECTION 3204.2 - THE DESIGNATION OF HIGH-PILED COMBUSTIBLE STORAGE AREA IS ALLOWED TO BE BASED ON A LOWER HAZARD CLASS THAN THAT OF THE HIGHEST CLASS OF COMMODITY STORED WHERE A LIMITED QUANTITY OF THE HIGHER HAZARD COMMODITY HAS BEEN ADEQUATELY PROTECTED
BY THE AUTOMATIC SPRINKLER SYSTEM PROVIDED DEMONSTRATED BY ENGINEERING ANALYSIS.
HIGH HAZARD STORAGE WITHIN MIXED STORAGE IS LIMITED TO 120 SF, AND SEPERATED FROM OTHER
HIGH HAZARD STORAGE AREAS BY A MINIMUM OF 25 FEET.
SMOKE DETECTION SYSTEM YES PER 907.2.14 EXISTING EXISTING
NOTE: FIRE SPRINKLER SYSTEM TO BE ELECTRONICALLY SUPERVISED BY AN APPROVED OFFSITE
STATION.
FIRE DEPARTMENT ACCESS DOORS YES PER 435.5 YES N/A
SMOKE/HEAT REMOVAL SYSTEM NOT REQURIED PER 435.5
(H)
NO N/A
ALLOWABLE STORAGE CONFIGURATION: BASED ON OFC TABLE 3206.2 AND CLASS III COMMODITY
STORAGE OVER 12000 SF.
MEANS OF EGRESS
EGRESS WIDTH PER OCCUPANT SERVED (SECTION 1005.3):
OTHER EGRESS COMPONENTS: (0.2"/OCC) = REFER TO BUILDING EXITING ON THIS SHEET
44" MINIMUM EGRESS WIDTH REQUIRED PER 1011.2
CHAPTER 10
NUMBER OF EXITS (1006):
NUMBER OF EXITS REQUIRED PER STORY PER TABLE 1006.3.2 = 2
ILLUMINATED EXIT SIGNS: REQUIRED PER 1013.3
COMMON PATH OF EGRESS TRAVEL DISTANCE (1006.2.1)
OCC B = 100'-0" OCC S = 100'-0"
EXIT ACCESS TRAVEL DISTANCE (1017):
OCC B = 300'-0" OCC S = 250'-0"
EXIT ACCESS ILLUMINATION REQUIREMENT:
EGRESS LIGHTING REQUIRED ALONG THE EGRESS PATH TO THE R.O.W. PER SECTION 1008.
PERFORMANCE REQUIREMENTS:
AVERAGE OF 1fc WITH A MINIMUM OF 0.1fc AT ANY POINT ON THE EGRESS PATH AT FLOOR LEVEL LIGHT LEVEL MAY DECLINE TO AVERAGE OF 0.6fc WITH A MINUMN OF 0.06fc AT ANY POINT ON THE EGRESS
PATH AT FLOOR LEVEL AFTER 90 MINUTES OF OPERATION ON EMERGENCY POWER.
MAXIMUM TO MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED.
POWER PROVIDED BY BATTERY INVERTERS (EMERGENCY GENERATOR) (REFERECE ELECTRICAL
DOCUMENTS)
1/8" = 1'-0"
EXISTING FIRE RISER
VICINITY MAP
AREA OF W
ORK
HIGH BAY SHELVING CHAPTER 32
ALLOWABLE STORAGE CONFIGURATION: BASED ON COMMODITY CLASS III, COMBUSTIBLE MATERIAL, 12,001-500,00 SF PER OFC 3203.4 AND OFC TABLE 3206.2.
MAXIMUM SOLID-PILE DIMENSION
MAXIMUM SOLID-PILE HEIGHT
MAXIMUM SOLID-PILE VOLUME
ALLOWABLE PROPOSED
120 FEET 98'-0"
40 FEET
400,000 CU. FT. 171,600 CU. FT.
PER OFC SECTION 3206.10.3 - DEAD END ISLES SHALL BE LIMITED TO 50 FEET.
20 FEET
PER OFC SECTION 3208.3 - A 6" MINIMUM TRANSVERSE FLUE SPACE IS REQUIRED BETWEEN DOUBLE ROW RACKS UP TO 25 FEET IN HEIGHT WHERE THE SPRINKLER IS LOCATED AT THE CEILING WITH NO IN-RACK
SPRINKLERS. A 3" MINIMUM TRANSVERSE FLUE SPACE IS REQUIRED AT SINGLE ROW RACKS.
MIXED CLASS III COMMODITY
1/16" = 1'-0"
LEVEL 01- HIGH DENSITY STORAGE PLAN
A Addendum A 11/16/21
A
Attachment 1 to Addendum 004
| ADDENDUM No: 004 |
| STATE OF OREGON |
| End of Addendum 004 |
| Attachment1_Addendum004.pdf |
| Sheets |
| A101 - FLOOR PLAN - LEVEL 01 |
File details come from the government source that posted it. Updated .