7/04
ENGINEERED PRODUCTS
Model • RT(S0-80) (A, B)t J Unit Type (UT)• RT, Natural Vent Rooftop Unit
Capacity (CA) • (50-80) (500-800 mBTU) Furnace Type (FT) • A, B Standard Temperature Rise (20-60)F0
Rooftop Arrangement (RA) - J, High CFM Blower Unit with Supply Plenum
CAPACITY
D 50
D 60
D 70
~ 80
NOTE:
i 6-112·
(165) ,- - - " ·5/16" _ _ .,.... ____ _ &&-1/16' _ I c1126, ,6s-112• ,21 66, 1•204)
USA Canada
A B C D D
43- 7/8 29- 5/16 23- 112 16 25- 3/16
(1114) (745) (597) (406) (640)
54. 7/8 34-13/16 26 17. 112 26-11/16
(1394) (884) (660) (445) (678)
54. 7/8 40, 5/16 26 17- 1/2 26-11/16
(1394) (1024) (660) (445) (678)
60· 3/8 45-13/16 26 17- 1/2 26·11/16
(1534) (1 164) (660) (445) (678)
•F
34. 1/2
(876)
37. 1/4
(946)
45. 1/2
(1156)
(1295)
DIMENSIONS ARE IN INCHES. DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.
G
42- 1116
(1068)
53. 1/16
(1348)
53-1116
(1348)
58- 9/16 (1487)
• •F• DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S) .
.t.•J• DIMENSION IS AN OUTSIDE DIMENSION FOR AIR DAMPERS .
.A. .J. DIMENSION IS AN INSIDE DIMENSION FOR SUPPLY AIR (WITHOUT DAMPER).
GAS INLET
Jt.J NAT LP
35 3/4 112 OR 3/4
(889)
46 3/4 1/2 OR 3/4
(1 168)
46 3/4 1/2 OR 3/4
(1168)
51- 1/2 3/4 1/2 OR 3/4
(1308)
APPROVED
RT-80-J-4
·/hd2 ;l.--/J-202J
Project: FCI Eikton
Unit Tag: ________ _
0 .., __ .... ·--~ .:, 1 1:f!fc,!~~®
260 NORTH ELM ST. WESTFIELD, MA 01085
(413) 564-5540 • FAX: (413) 562-53 11
www.slerllnghvoc.com ♦ ., ,,mru COMP•NY
NERO FACILITIES AD MIN ISTRATOR
The above dimensional drawing includes options that might not pertain to the unit being submitted for approval. Please note that the following items checked below are not Included with the unit being submitted:
D Outside Air Opening I Dampers
O Return Air Openings / Dampers
D Outside Air Hood
ENGINEERED PRODUCTS
RT-80-J-4
Model
Dl9lts Mu.
3, 4, & 5 I Input STU/Hr. Output
CA.FT ('F) CFM I Mu. I Min, BTU/Hr.
50AIB 119 3,100 500,000 200.000 400,000
92 4,000
74 5,000
61 8,000
53 7,000
49 7,500
BOA/B 120 3,700 600,000 240,000 480,000
111 4,000
74 6,000
55 8,000
44 10,000
40 11,000
70A/B 115 4,500 700,000 280,000 560,000
86 6,000
65 8,000
52 10,000
43 12,000
40 13,000
80AIB 118 5,000 800,000 320,000 640,000
98 8,000
74 8,000 59 10,000
49 12.000
44 13,500
RT{S0-80) (A, B)t J Performance Table
TOTAL EXTERNAL STATIC PRESSURE
(INCHES OF WATER)
0,4 0.8 1 1.4
RPM BHP RPM BHP RPM BHP RPM BHP RPM
565 .76 810 1.01 740 1.14 845 1.45 945
875 1.45 755 1.74 805 1.90 895 2.21 1180 810 2.67 870 2.98 900 3.16 975 3.55 1045
955 4.46 1000 4.80 1020 4,98 1075 5.40 1135
1100 6.94 1135 7.32 1155 7.52 1195 7.95 1240
1175 8.48 1205 8.88 1225 9.08 1260 9.52
545 ,74 700 1.19 775 1.45 915 2.02 1035
560 .86 710 1.33 780 1,59 915 2.18 1035
700 2.12 810 2.73 865 3.05 965 3.72 1065
855 ◄ .38 950 5.17 990 5.57 1075 6.39 1155
1025 7.96 1100 8.94 1140 9.43 1210 10.◄2 1280
1110 10.35 1180 11,41 1215 11.95 1280 13.04 1345
525 .85 170 1.31 735 1.55 850 2.06 955 610 1,63 725 2.12 780 2.42 890 3.05 985
735 3.35 830 3,98 875 4.29 960 4.96 1045
880 6.09 950 6.85 HO 7.25 1060 6.03 1130
1030 10.13 1081 10.97 1115 11.43 1175 12.38 1240
1110 12.71 1155 13.59 1185 14.08
835 t.01 870 1.47 735 1,74 850 2.28 950
585 1.54 705 2.02 760 2.30 870 2.93 9155
710 3.15 aoo 3.n 845 4.08 935 4.72 1020
850 5.75 915 6.45 950 8.84 1025 7.83 10115
995 9.58 1045 10.35 1075 10.77 1130 11.69 1195
1110 13.41 1150 14.23 1175 14.sa
1.8 2
BHP RPM BHP
1.78 990 1.95
2.56 1020 2.76
3.94 1085 4.13
5.86 1165 6,10
8.42 1265 8 .68
2,65 1090 2.97
2.83 1090 3.16
4.45 1110 4,83
7.24 1195 7.68
11 .43 1310 11 .95
14,14 1375 14.69
2.60 1000 2 .88
3.71 1030 4.04
5.74 1(185 6.16
8.82 1165 923
13.33 1270 13.79
2.85 995 3.14
3.58 1015 3.91
5.47 1060 5.88
8.41 1130 8 .81
12.65 1225 13.12
NOTES: The pressure drop for Accessories from the following table, must be allowed for when using the above Performance table.
Unless otherwise specified, the following conversions may be used for calculating SI units.
1 Cu. Ft.= 0.028m3 , 1 ft.= 0.305m, 1 in.= 25.4mm, 1 psig = 6.894 kPa, 1000 Btu per hr. = 0.293 kW, 1 in. water column= 0.249 kPa, 1 gallon= 3.785 L, 1000 Btu/Cu. Ft.= 37.5 MJ/m3, 1 lb.= 0.453 kg.
RT-80-J.4
Page 3 of 4 flSTERLiN& ~ HVAC PRODUCTS
RT(50-80) (A, B)t J Accessories Pressure Drop Table
PRESSURE LOSS INCHES OF WATER
RAIHHOOD FILTERS OUTSIDE OR
WITH HROWAWAY WASHABLE PLEATED SUPPLY RETURN
CAPACITY CFM SCREEN ELIM zw r 2" r zw PLENUM DAMPER
3,100 .06 .08 .06 .01 .02 .08 .04 .06 .09 4 ,000 ,09 .13 .09 .02 .03 .12 .07 .09 .15
50 5,000 ,15 .20 .12 .03 .04 .17 .10 .14 .23 8,000 .21 .29 .16 .04 .06 .23 .14 .21 .33 7,000 .29 .40 .19 .06 .08 .30 .18 .28 .45 7,500 .33 .46 - .07 .09 .34 .21 .32 .52
3,700 .OS .07 .04 <.01 <.01 .05 .02 .05 .07
4,000 .05 .08 .05 <,01 .01 .05 .03 .08 .08 eo 6,000 .12 .17 .OB .02 .02 .10 .06 ,13 .19 8,000 .22 .31 .12 .03 ,04 ,1 7 .10 .24 .33
10,000 .34 .48 .16 .04 .06 .24 .14 .37 .52 11,000 ,4 1 ,58 ,18 .05 .08 .28 ,17 .45 .63 4,500 .07 .10 .05 <.01 .01 .06 .03 ,06 .11 6,000 .12 .17 .08 .02 .02 .10 .08 .11 .19
70 8,000 .22 .31 .12 .03 .04 .17 .10 .19 .33 10,000 .34 .48 .16 .04 .06 .24 .14 .30 .52 12,000 .49 .69 - .06 .09 .33 .20 .43 .75 13,000 .58 .81 - .07 .1 1 .38 .23 .51 .88 15,000 .07 . 10 .05 <.01 .01 .06 .03 .06 .10 6,000 .10 .14 .07 .01 .02 .08 .04 .08 .15
80 8,000 .17 .24 . 10 .02 .03 ,13 .07 .15 .28
10,000 .27 .38 .13 .03 .OS .19 .11 .23 ,41
12,000 .39 .55 ,17 .05 ,07 .26 .16 .34 .59 13,500 .49 .70 - .06 .09 .31 .19 .43 .75
RT-80-J-4
RT(S0-80) (A, B)t J
0 STERLiN\i
HVAC PRODUCTS
Weights, Filter Data & Roof Openings Unit Weights Filter Data
Approximate weights for Arrangement "J"t (Quantity)
Unit Type Net Wl,t Ship Wt.t Add for Capacity FIiter Siu
Capacity (lb.) (lb.) Outside Air Hood 50 (8) 20 X 20
RT50 1329 1519 51 60, 70 (8) 16x20
RT60 1571 1n2 59 (4) 20 X 20
RT70 1638 1839 59 80 (12)20 X 20
RT80 1755 1961 63
Convenilon 1 lb. = 0.453 kg.
tThe approximate net and shipping weights shown are for a basic unit (these weights do not include the motor, air hood or any options). If the unit ts equipped wHh an outside air hood, add the weights accordingly (see above). Also add in the motor weight; see motor specifications sheet #MOS-1 for these weights/amperages.
Roof Openings
2-1/2 04l,IPCR [XTCNSION (84)
L UHIT e,;.s[ II-"
WITH CUR8 C>J'
SO: DETAIL
T
.. ...,.,, ...... IUCT'IUCN. oucr t\#UUia
, I . r
I S/1 6 oucr MOUNTING fl.AN]( (24)
OUC'T NJbiWX SU"'I.T NJilUW
--·· A - - [J - - - - (.1 - '" I
(4 6:) CURB/Fl.ASHING u 8Y OTHERS
'- -0 SUPPLY
mtJ&t=======#lll.fim-1
RCTUIIM V' '
1·-1•--0
(2S) CIAIIP[R O.S.
OA
PI.ENUM I.S.
Aoor OPENING
CAPACITY <CA) D E
so JS' JT
(889) (940)
60/7D 48" ...
(1 , 118) ( 1.219)
80 1:~t ff.~,f
4- 1 I /15 (BOTH SIDES)
(1 19)
18-S-1/ (129)
MODEL NUMBER
1 2 3 4 5 6 t
-1e-1/a- (471)
OAMP£A O,S.
-20-7/1
(SJO)
ROOF OP[NNG
-1· (25)
11 l" (2 ,870)
CURB CAP END ACAPT0/1~5· '
SUPPUEO WITH UNIT. •
INV[J'lf IN PLACE AS SHOWN . \_
SEAL ALI. JOINfS Ir SCAMS • • • l - 1/8 (BOTH CHO$)
(79) DETAIL 1,
This Arrangement may be used with Sterling
ROOF CURB KIT #(U)RC009.
7 8 9 10 11 12 13 14 15 16
J I I I I I I I I
(2S)
,-1a-1;1- (479)
PLENUM I.S.
20-7/8- (530)
ROOF OPCNING
DIGITS 3 & ,4 a (CA) CAPACITY, DIGIT, 5 " (FT) FURNACE TYPE, DIGIT 6"' t(FM) FURNACE MATERIAL
REFER TO CATALOG FOR MODEL NUMBER DESCRIPTION.
-•-5/8 (117)