Model - RT(50-80) (A, B)† J Unit Type (UT) - RT, Natural Vent Rooftop Unit
Capacity (CA) - (50-80) (500-800 mBTU) Furnace Type (FT) - A, B Standard Temperature Rise (20-60)F°
Rooftop Arrangement (RA) - J, High CFM Blower Unit with Supply Plenum
ENGINEERED PRODUCTS
RT-80-J-4
USA Canada GAS INLET
CAPACITY A B C D D *F G ▲J NAT LP
□ 50
43- 7/8 29- 5/16 23- 1/2 16 25- 3/16 34- 1/2 42- 1/16 35 3/4 1/2 OR 3/4
(1114) (745) (597) (406) (640) (876) (1068) (889)
□ 60
54- 7/8 34-13/16 26 17- 1/2 26-11/16 37- 1/4 53- 1/16 46 3/4 1/2 OR 3/4
(1394) (884) (660) (445) (678) (946) (1348) (1168)
□ 70
54- 7/8 40- 5/16 26 17- 1/2 26-11/16 45- 1/2 53- 1/16 46 3/4 1/2 OR 3/4
(1394) (1024) (660) (445) (678) (1156) (1348) (1168)
□ 80
60- 3/8 45-13/16 26 17- 1/2 26-11/16 51 58- 9/16 51- 1/2 3/4 1/2 OR 3/4
(1534) (1164) (660) (445) (678) (1295) (1487) (1308)
NOTE:
DIMENSIONS ARE IN INCHES, DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.
* “F” DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S).
▲“J” DIMENSION IS AN OUTSIDE DIMENSION FOR AIR DAMPERS.
▲“J” DIMENSION IS AN INSIDE DIMENSION FOR SUPPLY AIR (WITHOUT DAMPER).
A
5" (127)
1-5/16" (33) Typ.
Anchor Hole Location
F
3-9/16" (90)
Supply Opening
CL
1" (25) Curb Cap
C (Typ.)
G
39" (991)
D
J Inside
18-7/8" (479) x J Typ.
Inside Opening
Electrical Connections
Vent Caps Are Shipped In Separate Cartons
6-1/16" (154)
Gas Connections
6-1/16" (154)
86-1/16" (2186)
0.625 (16) Typ.
Anchor Hole Location
DFR3559
TFR3544
Optional Outside Air Hood
Optional Moisture Eliminators
19-1/2" (495)
6-1/2" (165)
Lifting Brackets
18-7/8" (479) x J Typ.
O.S. Damper Opening
18-7/8" (479) x J Typ.
O.S. Damper Opening
44-5/16" (1126)
34-3/4" (883)
160-1/2" (4077)
Damper Location
2-1/2" (64)
26" (660)
26" (660)
26" (660)
2-1/2" (64)
Outside
34-11/16" (881)
26" (660)
165-1/2" (4204)
9/16" Hole
9/16" Hole
260 NORTH ELM ST. WESTFIELD, MA 01085
(413) 564-5540 • FAX: (413) 562-5311
HVAC PRODUCTS
www.sterlinghvac.com
Project:
Unit Tag:
The above dimensional drawing includes options that might not pertain to the unit being submitted for approval. Please note that the following items checked below are not included with the unit being submitted:
□ Outside Air Opening / Dampers □ Outside Air Hood
□ Return Air Openings / Dampers
7/04
FCI Eikton
Mark Highlight
Mark Highlight
Mark Highlight
Mark Highlight
Mark Highlight
Mark Highlight
Mark Highlight
ENGINEERED PRODUCTS
NOTES: The pressure drop for Accessories from the following table, must be allowed for when using the above Performance table.
Unless otherwise specified, the following conversions may be used for calculating SI units.
1 Cu. Ft. = 0.028m3 , 1 ft. = 0.305m, 1 in. = 25.4mm, 1 psig = 6.894 kPa, 1000 Btu per hr. = 0.293 kW, 1 in. water column = 0.249 kPa, 1 gallon = 3.785 L, 1000 Btu/Cu. Ft. = 37.5 MJ/m3, 1 lb. = 0.453 kg.
RT(50-80) (A, B)† J
Performance Table
Model TOTAL EXTERNAL STATIC PRESSURE
Digits Max. (INCHES OF WATER)
3, 4, & 5 Input BTU/Hr. Output 0.4 0.8 1 1.4 1.8 2
CA, FT (°F) CFM Max. Min. BTU/Hr. RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
50 A/B 119 3,100 500,000 200,000 400,000 565 .76 680 1.01 740 1.14 845 1.45 945 1.78 990 1.95
92 4,000 675 1.45 755 1.74 805 1.90 895 2.21 980 2.56 1020 2.76
74 5,000 810 2.67 870 2.98 900 3.16 975 3.55 1045 3.94 1085 4.13
61 6,000 955 4.46 1000 4.80 1020 4.98 1075 5.40 1135 5.86 1165 6.10
53 7,000 1100 6.94 1135 7.32 1155 7.52 1195 7.95 1240 8.42 1265 8.68
49 7,500 1175 8.48 1205 8.88 1225 9.08 1260 9.52
60 A/B 120 3,700 600,000 240,000 480,000 545 .74 700 1.19 775 1.45 915 2.02 1035 2.65 1090 2.97
111 4,000 560 .86 710 1.33 780 1.59 915 2.18 1035 2.83 1090 3.16
74 6,000 700 2.12 810 2.73 865 3.05 965 3.72 1065 4.45 1110 4.83
55 8,000 855 4.38 950 5.17 990 5.57 1075 6.39 1155 7.24 1195 7.68
44 10,000 1025 7.96 1100 8.94 1140 9.43 1210 10.42 1280 11.43 1310 11.95
40 11,000 1110 10.35 1180 11.41 1215 11.95 1280 13.04 1345 14.14 1375 14.69
70 A/B 115 4,500 700,000 280,000 560,000 525 .85 670 1.31 735 1.55 850 2.06 955 2.60 1000 2.88
86 6,000 610 1.63 725 2.12 780 2.42 890 3.05 985 3.71 1030 4.04
65 8,000 735 3.35 830 3.98 875 4.29 960 4.96 1045 5.74 1085 6.16
52 10,000 880 6.09 950 6.85 990 7.25 1060 8.03 1130 8.82 1165 9.23
43 12,000 1030 10.13 1085 10.97 1115 11.43 1175 12.38 1240 13.33 1270 13.79
40 13,000 1110 12.71 1155 13.59 1185 14.08
80 A/B 118 5,000 800,000 320,000 640,000 535 1.01 670 1.47 735 1.74 850 2.28 950 2.85 995 3.14
98 6,000 585 1.54 705 2.02 760 2.30 870 2.93 965 3.58 1015 3.91
74 8,000 710 3.15 800 3.77 845 4.08 935 4.72 1020 5.47 1060 5.88
59 10,000 850 5.75 915 6.45 950 6.84 1025 7.63 1095 8.41 1130 8.81
49 12,000 995 9.58 1045 10.35 1075 10.77 1130 11.69 1195 12.65 1225 13.12
44 13,500 1110 13.41 1150 14.23 1175 14.68
RT-80-J-4
Mark Highlight
Mark Highlight
HVAC PRODUCTS
PRESSURE LOSS (INCHES OF WATER)
RAINHOOD FILTERS OUTSIDE OR
WITH THROWAWAY WASHABLE PLEATED SUPPLY RETURN
CAPACITY CFM SCREEN ELIM 2” 1" 2" 1" 2" PLENUM DAMPER
3,100 .06 .08 .06 .01 .02 .08 .04 .06 .09 4,000 .09 .13 .09 .02 .03 .12 .07 .09 .15
50 5,000 .15 .20 .12 .03 .04 .17 .10 .14 .23 6,000 .21 .29 .16 .04 .06 .23 .14 .21 .33 7,000 .29 .40 .19 .06 .08 .30 .18 .28 .45 7,500 .33 .46 — .07 .09 .34 .21 .32 .52 3,700 .05 .07 .04 <.01 <.01 .05 .02 .05 .07 4,000 .05 .08 .05 <.01 .01 .05 .03 .06 .08
60 6,000 .12 .17 .08 .02 .02 .10 .06 .13 .19 8,000 .22 .31 .12 .03 .04 .17 .10 .24 .33
10,000 .34 .48 .16 .04 .06 .24 .14 .37 .52 11,000 .41 .58 .18 .05 .08 .28 .17 .45 .63
4,500 .07 .10 .05 <.01 .01 .06 .03 .06 .11 6,000 .12 .17 .08 .02 .02 .10 .06 .11 .19
70 8,000 .22 .31 .12 .03 .04 .17 .10 .19 .33 10,000 .34 .48 .16 .04 .06 .24 .14 .30 .52 12,000 .49 .69 — .06 .09 .33 .20 .43 .75 13,000 .58 .81 — .07 .11 .38 .23 .51 .88 15,000 .07 .10 .05 <.01 .01 .06 .03 .06 .10
6,000 .10 .14 .07 .01 .02 .08 .04 .08 .15 80 8,000 .17 .24 .10 .02 .03 .13 .07 .15 .26
10,000 .27 .38 .13 .03 .05 .19 .11 .23 .41 12,000 .39 .55 .17 .05 .07 .26 .16 .34 .59 13,500 .49 .70 — .06 .09 .31 .19 .43 .75
RT(50-80) (A, B)† J
Accessories Pressure Drop Table
RT-80-J-4
Mark Highlight
Mark Highlight
Mark Highlight
Mark Highlight
HVAC PRODUCTS
MODEL NUMBER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +
(EXX) R T * * * † J
DIGITS 3 & 4 = (CA) CAPACITY, DIGIT, 5 = (FT) FURNACE TYPE, DIGIT 6 = †(FM) FURNACE MATERIAL.
REFER TO CATALOG FOR MODEL NUMBER DESCRIPTION.
RT(50-80) (A, B)† J
Weights, Filter Data & Roof Openings
Unit Weights
Filter Data (Quantity)
Capacity Filter Size
50 (8) 20 x 20
60, 70 (8) 16 x 20
(4) 20 x 20
80 (12) 20 x 20
Approximate weights for Arrangement “J”†
Unit Type Net Wt.† Ship Wt.† Add for
Capacity (Lb.) (Lb.) Outside Air Hood
RT50 1329 1519 51
RT60 1571 1772 59
RT70 1638 1839 59
RT80 1755 1961 63
Conversion 1 lb. = 0.453 kg.
†The approximate net and shipping weights shown are for a basic unit (these weights do not include the motor, air hood or any options). If the unit is equipped with an outside air hood, add the weights accordingly (see above). Also add in the motor weight; see motor specifications sheet #MDS-1 for these weights/amperages.