Model - RT(50-80) (A, B)† J Unit Type (UT) - RT, Natural Vent Rooftop Unit

Capacity (CA) - (50-80) (500-800 mBTU) Furnace Type (FT) - A, B Standard Temperature Rise (20-60)F°

Rooftop Arrangement (RA) - J, High CFM Blower Unit with Supply Plenum

ENGINEERED PRODUCTS

RT-80-J-4

USA Canada GAS INLET

CAPACITY A B C D D *F G ▲J NAT LP

□ 50

43- 7/8 29- 5/16 23- 1/2 16 25- 3/16 34- 1/2 42- 1/16 35 3/4 1/2 OR 3/4

(1114) (745) (597) (406) (640) (876) (1068) (889)

□ 60

54- 7/8 34-13/16 26 17- 1/2 26-11/16 37- 1/4 53- 1/16 46 3/4 1/2 OR 3/4

(1394) (884) (660) (445) (678) (946) (1348) (1168)

□ 70

54- 7/8 40- 5/16 26 17- 1/2 26-11/16 45- 1/2 53- 1/16 46 3/4 1/2 OR 3/4

(1394) (1024) (660) (445) (678) (1156) (1348) (1168)

□ 80

60- 3/8 45-13/16 26 17- 1/2 26-11/16 51 58- 9/16 51- 1/2 3/4 1/2 OR 3/4

(1534) (1164) (660) (445) (678) (1295) (1487) (1308)

NOTE:

DIMENSIONS ARE IN INCHES, DIMENSIONS IN PARENTHESIS ARE IN MILLIMETERS.

* “F” DIMENSION IS THE RECOMMENDED CLEARANCE TO SERVICE THE BURNER DRAWER(S).

▲“J” DIMENSION IS AN OUTSIDE DIMENSION FOR AIR DAMPERS.

▲“J” DIMENSION IS AN INSIDE DIMENSION FOR SUPPLY AIR (WITHOUT DAMPER).

A

5" (127)

1-5/16" (33) Typ.

Anchor Hole Location

F

3-9/16" (90)

Supply Opening

CL

1" (25) Curb Cap

C (Typ.)

G

39" (991)

D

J Inside

18-7/8" (479) x J Typ.

Inside Opening

Electrical Connections

Vent Caps Are Shipped In Separate Cartons

6-1/16" (154)

Gas Connections

6-1/16" (154)

86-1/16" (2186)

0.625 (16) Typ.

Anchor Hole Location

DFR3559

TFR3544

Optional Outside Air Hood

Optional Moisture Eliminators

19-1/2" (495)

6-1/2" (165)

Lifting Brackets

18-7/8" (479) x J Typ.

O.S. Damper Opening

18-7/8" (479) x J Typ.

O.S. Damper Opening

44-5/16" (1126)

34-3/4" (883)

160-1/2" (4077)

Damper Location

2-1/2" (64)

26" (660)

26" (660)

26" (660)

2-1/2" (64)

Outside

34-11/16" (881)

26" (660)

165-1/2" (4204)

9/16" Hole

9/16" Hole

260 NORTH ELM ST. WESTFIELD, MA 01085

(413) 564-5540 • FAX: (413) 562-5311

HVAC PRODUCTS

www.sterlinghvac.com

Project:

Unit Tag:

The above dimensional drawing includes options that might not pertain to the unit being submitted for approval. Please note that the following items checked below are not included with the unit being submitted:

□ Outside Air Opening / Dampers □ Outside Air Hood

□ Return Air Openings / Dampers

7/04

FCI Eikton

Mark Highlight

Mark Highlight

Mark Highlight

Mark Highlight

Mark Highlight

Mark Highlight

Mark Highlight

ENGINEERED PRODUCTS

NOTES: The pressure drop for Accessories from the following table, must be allowed for when using the above Performance table.

Unless otherwise specified, the following conversions may be used for calculating SI units.

1 Cu. Ft. = 0.028m3 , 1 ft. = 0.305m, 1 in. = 25.4mm, 1 psig = 6.894 kPa, 1000 Btu per hr. = 0.293 kW, 1 in. water column = 0.249 kPa, 1 gallon = 3.785 L, 1000 Btu/Cu. Ft. = 37.5 MJ/m3, 1 lb. = 0.453 kg.

RT(50-80) (A, B)† J

Performance Table

Model TOTAL EXTERNAL STATIC PRESSURE

Digits Max. (INCHES OF WATER)

3, 4, & 5 Input BTU/Hr. Output 0.4 0.8 1 1.4 1.8 2

CA, FT (°F) CFM Max. Min. BTU/Hr. RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

50 A/B 119 3,100 500,000 200,000 400,000 565 .76 680 1.01 740 1.14 845 1.45 945 1.78 990 1.95

92 4,000 675 1.45 755 1.74 805 1.90 895 2.21 980 2.56 1020 2.76

74 5,000 810 2.67 870 2.98 900 3.16 975 3.55 1045 3.94 1085 4.13

61 6,000 955 4.46 1000 4.80 1020 4.98 1075 5.40 1135 5.86 1165 6.10

53 7,000 1100 6.94 1135 7.32 1155 7.52 1195 7.95 1240 8.42 1265 8.68

49 7,500 1175 8.48 1205 8.88 1225 9.08 1260 9.52

60 A/B 120 3,700 600,000 240,000 480,000 545 .74 700 1.19 775 1.45 915 2.02 1035 2.65 1090 2.97

111 4,000 560 .86 710 1.33 780 1.59 915 2.18 1035 2.83 1090 3.16

74 6,000 700 2.12 810 2.73 865 3.05 965 3.72 1065 4.45 1110 4.83

55 8,000 855 4.38 950 5.17 990 5.57 1075 6.39 1155 7.24 1195 7.68

44 10,000 1025 7.96 1100 8.94 1140 9.43 1210 10.42 1280 11.43 1310 11.95

40 11,000 1110 10.35 1180 11.41 1215 11.95 1280 13.04 1345 14.14 1375 14.69

70 A/B 115 4,500 700,000 280,000 560,000 525 .85 670 1.31 735 1.55 850 2.06 955 2.60 1000 2.88

86 6,000 610 1.63 725 2.12 780 2.42 890 3.05 985 3.71 1030 4.04

65 8,000 735 3.35 830 3.98 875 4.29 960 4.96 1045 5.74 1085 6.16

52 10,000 880 6.09 950 6.85 990 7.25 1060 8.03 1130 8.82 1165 9.23

43 12,000 1030 10.13 1085 10.97 1115 11.43 1175 12.38 1240 13.33 1270 13.79

40 13,000 1110 12.71 1155 13.59 1185 14.08

80 A/B 118 5,000 800,000 320,000 640,000 535 1.01 670 1.47 735 1.74 850 2.28 950 2.85 995 3.14

98 6,000 585 1.54 705 2.02 760 2.30 870 2.93 965 3.58 1015 3.91

74 8,000 710 3.15 800 3.77 845 4.08 935 4.72 1020 5.47 1060 5.88

59 10,000 850 5.75 915 6.45 950 6.84 1025 7.63 1095 8.41 1130 8.81

49 12,000 995 9.58 1045 10.35 1075 10.77 1130 11.69 1195 12.65 1225 13.12

44 13,500 1110 13.41 1150 14.23 1175 14.68

RT-80-J-4

Mark Highlight

Mark Highlight

HVAC PRODUCTS

PRESSURE LOSS (INCHES OF WATER)

RAINHOOD FILTERS OUTSIDE OR

WITH THROWAWAY WASHABLE PLEATED SUPPLY RETURN

CAPACITY CFM SCREEN ELIM 2” 1" 2" 1" 2" PLENUM DAMPER

3,100 .06 .08 .06 .01 .02 .08 .04 .06 .09 4,000 .09 .13 .09 .02 .03 .12 .07 .09 .15

50 5,000 .15 .20 .12 .03 .04 .17 .10 .14 .23 6,000 .21 .29 .16 .04 .06 .23 .14 .21 .33 7,000 .29 .40 .19 .06 .08 .30 .18 .28 .45 7,500 .33 .46 — .07 .09 .34 .21 .32 .52 3,700 .05 .07 .04 <.01 <.01 .05 .02 .05 .07 4,000 .05 .08 .05 <.01 .01 .05 .03 .06 .08

60 6,000 .12 .17 .08 .02 .02 .10 .06 .13 .19 8,000 .22 .31 .12 .03 .04 .17 .10 .24 .33

10,000 .34 .48 .16 .04 .06 .24 .14 .37 .52 11,000 .41 .58 .18 .05 .08 .28 .17 .45 .63

4,500 .07 .10 .05 <.01 .01 .06 .03 .06 .11 6,000 .12 .17 .08 .02 .02 .10 .06 .11 .19

70 8,000 .22 .31 .12 .03 .04 .17 .10 .19 .33 10,000 .34 .48 .16 .04 .06 .24 .14 .30 .52 12,000 .49 .69 — .06 .09 .33 .20 .43 .75 13,000 .58 .81 — .07 .11 .38 .23 .51 .88 15,000 .07 .10 .05 <.01 .01 .06 .03 .06 .10

6,000 .10 .14 .07 .01 .02 .08 .04 .08 .15 80 8,000 .17 .24 .10 .02 .03 .13 .07 .15 .26

10,000 .27 .38 .13 .03 .05 .19 .11 .23 .41 12,000 .39 .55 .17 .05 .07 .26 .16 .34 .59 13,500 .49 .70 — .06 .09 .31 .19 .43 .75

RT(50-80) (A, B)† J

Accessories Pressure Drop Table

RT-80-J-4

Mark Highlight

Mark Highlight

Mark Highlight

Mark Highlight

HVAC PRODUCTS

MODEL NUMBER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 +

(EXX) R T * * * † J

DIGITS 3 & 4 = (CA) CAPACITY, DIGIT, 5 = (FT) FURNACE TYPE, DIGIT 6 = †(FM) FURNACE MATERIAL.

REFER TO CATALOG FOR MODEL NUMBER DESCRIPTION.

RT(50-80) (A, B)† J

Weights, Filter Data & Roof Openings

Unit Weights

Filter Data (Quantity)

Capacity Filter Size

50 (8) 20 x 20

60, 70 (8) 16 x 20

(4) 20 x 20

80 (12) 20 x 20

Approximate weights for Arrangement “J”†

Unit Type Net Wt.† Ship Wt.† Add for

Capacity (Lb.) (Lb.) Outside Air Hood

RT50 1329 1519 51

RT60 1571 1772 59

RT70 1638 1839 59

RT80 1755 1961 63

Conversion 1 lb. = 0.453 kg.

†The approximate net and shipping weights shown are for a basic unit (these weights do not include the motor, air hood or any options). If the unit is equipped with an outside air hood, add the weights accordingly (see above). Also add in the motor weight; see motor specifications sheet #MDS-1 for these weights/amperages.

Roof Openings

RT-80-J-4

This Arrangement may be used with Sterling

ROOF CURB KIT #(U)RC009.