Roof_Restoration_Scales_Elementary_Drawings.pdf

PDF 687 KB Posted

Attached to
Roof Restoration at Scales Elementary School
Solicitation number
ITB-40-2026
Issued by
Rutherford County, Tennessee

About this file

This is an architectural drawing document for a roof restoration project at Scales Elementary School, a City of Murfreesboro facility located at 2340 St Andrews Drive in Murfreesboro, Tennessee. The project, identified as J+B Project No. 2605, encompasses a comprehensive restoration of the school's existing roof system covering 135,000 square feet. The work involves preparation and installation of a reinforced fluid-applied roofing membrane system over the existing EPDM (ethylene propylene diene monomer) membrane, rigid insulation, and metal roof deck. Key preparation activities include performing an infrared moisture scan of the entire roof, removing and replacing wet insulation and damaged membrane sections, repairing existing cuts, punctures, blisters, and open seams in the EPDM, and preparing all roof surfaces to be clean, dry, and free of debris, oils, and contaminants. The restoration system requires reinforced coating and fabric detailing at all roof penetrations, curbs, drains, and transitions, with new coating walkways specified at 120 mil dry film thickness with an additional layer of reinforcing fabric and a minimum 30-inch width in a contrasting grey color. Sealed bids for the project (ITB-40-2026) are to be received by the City of Murfreesboro no later than Tuesday, June 23, 2026, at 2:00 pm CST.

The architectural drawings provided by Johnson + Bailey Architects P.C. include detailed roof preparation plans (Parts A and B), new work roof plans (Parts A and B), and construction details for roof drain and roof edge applications. Contractors are required to review all contract documents and specifications prior to bidding and construction, verify existing conditions, and coordinate work to maintain weather-tight conditions at all times. The fluid-applied roofing system must be installed in accordance with manufacturer's written requirements and project specifications, with installation coordinated by a manufacturer representative to ensure warranty issuance. Additional contractor responsibilities include protecting rooftop equipment, walls, and adjacent surfaces from overspray and coating materials, providing temporary protection of roof areas not completed at the end of each workday, and protecting the roof system from damage caused by other trades. The drawings include detailed keynotes and legends identifying specific repair and reinforcement areas throughout the roof structure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Johnson + Bailey Architects P.C.

Index

R o o f R e st o ra ti o n a t S c a le s E le m e n ta ry

S c h o o l J+

B

P R O

JE

C T N O .2

Roof Restoration at Scales Elementary

School

2340 St Andrews Dr Murfreesboro, TN 37128

J+B Project No. 2605

05-26-26

City of Murfreesboro

ARCHITECTURAL

A5.1 ROOF PREPARATION PLAN - PART A

A5.2 ROOF PREPARATION PLAN - PART B

A5.3 NEW WORK ROOF PLAN - PART A

A5.4 NEW WORK ROOF PLAN - PART B, DETAILS

V.T.R.

O.A.I.

E.F.

E.F.

E.F.

E.F.

O.A.I.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

C.A.

E.F.

E.F.

O.A.I.

E.F.

V.T.R. V.T.R.

O.A.I.

O.A.I.O.A.I.

O.A.I.O.A.I.O.A.I.

O.A.I.O.A.I.

E.F.

E.F. E.F.

E.F.

V.T.R.

V.T.R.

O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

V.T.R.

V.T.R.

V.T.R. V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I.

O.A.I.O.A.I.

E.F. E.F.

E.F.

E.F.

E.F.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

V.T.R.

V.T.R.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

E.F.

E.F.

E.F.

V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I.

O.A.I.O.A.I.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

E.F.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

E.J.

E.J.

E.J.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

GENERAL ROOF RESTORATION NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS INCLUDING

SPECIFICATIONS PRIOR TO BIDDING AND CONSTRUCTION.

EXISTING ROOF IS EPDM MEMBRANE OVER RIGID INSULATION AND METAL ROOF

DECK. CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO COMMENCEMENT OF

WORK.

PERFORM INFRARED MOISTURE SCAN OF ENTIRE ROOF PRIOR TO INSTALLATION OF

RESTORATION SYSTEM. REMOVE AND REPLACE WET INSULATION AND DAMAGED

MEMBRANE AS REQUIRED.

ALL ROOF SURFACES SHALL BE CLEAN, DRY, AND FREE OF DEBRIS, OILS, AND

CONTAMINANTS PRIOR TO INSTALLATION OF FLUID-APPLIED MEMBRANE SYSTEM.

REPAIR ALL CUTS, PUNCTURES, BLISTERS, AND OPEN SEAMS IN EXISTING EPDM

PRIOR TO APPLICATION OF RESTORATION SYSTEM.

CONTRACTOR SHALL COORDINATE WORK TO MAINTAIN WEATHER-TIGHT CONDITIONS

AT ALL TIMES.

FLUID-APPLIED ROOFING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER’S WRITTEN REQUIREMENTS AND PROJECT SPECIFICATIONS.

ALL ROOF PENETRATIONS, CURBS, DRAINS, AND TRANSITIONS SHALL RECEIVE

REINFORCED COATING AND FABRIC DETAILING.

PROTECT ROOFTOP EQUIPMENT, WALLS, AND ADJACENT SURFACES FROM

OVERSPRAY AND COATING MATERIALS.

PROVIDE TEMPORARY PROTECTION OF ROOF AREAS NOT COMPLETED AT THE END

OF EACH WORKDAY.

CONTRACTOR SHALL COORDINATE INSTALLATION WITH MANUFACTURER

REPRESENTATIVE INSPECTIONS REQUIRED FOR WARRANTY ISSUANCE.

PROTECT ROOF SYSTEM FROM DAMAGE CAUSED BY OTHER TRADES.

REVISIONREVISION DATEDATE

NOTES:NOTES:

THIS DRAWING SHALL NOT BE

REPRODUCED, PLUBLISHED, OR USED

IN ANY WAY WITHOUT THE WRITTEN

PERMISSION OF THE ARCHITECT.

PROJECT NO.PROJECT NO.

DATEDATE

DRAWN BYDRAWN BY

CHECKED BYCHECKED BY

Roof Restoration at Scales

Elementary School

2340 St Andrews Dr Murfreesboro, TN 37128

05-26-26

K.S.P.

J.B.A.

A5.1

SCALE 1/16" = 1'-0"

ROOF PREPARATION PLAN - PART A

ROOF PREPARATION KEYNOTE LEGEND

1 REMOVE EXISTING ROOF DRAIN BASKET AND RETAIN FOR REINSTALLATION. REMOVE EXISTING DRAIN CLAMPING RING

TAKING CARE NOT TO DAMAGE EXISTING DRAIN. FULLY CLEAN AND PREPARE ROOF DRAIN FOR INSTALLATION OF NEW FLUID APPLIED ROOF SYSTEM. REINSTALL CLAMPING RING AND BASKET AFTER APPLICATION OF LIQUID-APPLIED

ROOFING SYSTEM. SEE DETAIL 1/A5.4

2 PREPARE EXISTING PIPE PENETRATION FOR INSTALLATION OF NEW REINFORCED FLUID APPLIED ROOF SYSTEM.

REPLACE PIPE PENETRATION FLASHINGS WHERE DAMAGED.

3 REMOVE EXISTING SNAP-ON ROOF EDGE FASCIA COVER AND RETAIN FOR REINSTALLATION. REINSTALL EDGE FASCIA

AFTER APPLICATON OF LIQUID-APPLIED ROOFING SYSTEM. SEE DETAIL 2/A5.4

4 REMOVE EXISTING ROOF WALKWAY PADS. TAKE CARE NOT TO DAMAGE EXISTING EPDM MEMBRANE. REPAIR ANY DAMAGE TO EPDM MEMBRANE AND PREPARE SURFACE FOR INSTALLATION OF NEW LIQUID-APPLIED MEMBRANE.

5 REPAIR FLASHING AT ROOF-TO WALL TRANSITION WHERE DAMAGED. PREPARE FLASHINGS FOR INSTALLATION OF

NEW FLUID APPLIED ROOF SYSTEM.

6 REPAIR FLASHING AT SKYLIGHT CURBS WHERE DAMAGED. PREPARE FLASHINGS FOR INSTALLATION OF NEW FLUID

APPLIED ROOF SYSTEM.

7 REPAIR FLASHING AT EXISTING MECHANICAL EQUIP. CURBS WHERE DAMAGED. PREPARE FLASHINGS FOR

INSTALLATION OF NEW FLUID APPLIED ROOF SYSTEM.

O.A.I.

E.F.

E.F.

E.F.

E.F.

O.A.I.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

C.A.

E.F.

E.F.

O.A.I.

E.F.

V.T.R. V.T.R.

O.A.I.

O.A.I.O.A.I.

O.A.I.O.A.I.O.A.I.

O.A.I.O.A.I.

E.F.

E.F. E.F.

E.F.

V.T.R.

V.T.R.

O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

V.T.R.

V.T.R.

V.T.R. V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I.

O.A.I.O.A.I.

E.F. E.F.

E.F.

E.F.

E.F.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

V.T.R.

V.T.R.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

E.F.

E.F.

E.F.

V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I.

O.A.I.O.A.I.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

E.F.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

E.J.

E.J.

E.J.

E.J.

GENERAL ROOF RESTORATION NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS INCLUDING

SPECIFICATIONS PRIOR TO BIDDING AND CONSTRUCTION.

EXISTING ROOF IS EPDM MEMBRANE OVER RIGID INSULATION AND METAL ROOF

DECK. CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO COMMENCEMENT OF

WORK.

PERFORM INFRARED MOISTURE SCAN OF ENTIRE ROOF PRIOR TO INSTALLATION OF

RESTORATION SYSTEM. REMOVE AND REPLACE WET INSULATION AND DAMAGED

MEMBRANE AS REQUIRED.

ALL ROOF SURFACES SHALL BE CLEAN, DRY, AND FREE OF DEBRIS, OILS, AND

CONTAMINANTS PRIOR TO INSTALLATION OF FLUID-APPLIED MEMBRANE SYSTEM.

REPAIR ALL CUTS, PUNCTURES, BLISTERS, AND OPEN SEAMS IN EXISTING EPDM

PRIOR TO APPLICATION OF RESTORATION SYSTEM.

CONTRACTOR SHALL COORDINATE WORK TO MAINTAIN WEATHER-TIGHT CONDITIONS

AT ALL TIMES.

FLUID-APPLIED ROOFING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER’S WRITTEN REQUIREMENTS AND PROJECT SPECIFICATIONS.

ALL ROOF PENETRATIONS, CURBS, DRAINS, AND TRANSITIONS SHALL RECEIVE

REINFORCED COATING AND FABRIC DETAILING.

PROTECT ROOFTOP EQUIPMENT, WALLS, AND ADJACENT SURFACES FROM

OVERSPRAY AND COATING MATERIALS.

PROVIDE TEMPORARY PROTECTION OF ROOF AREAS NOT COMPLETED AT THE END

OF EACH WORKDAY.

CONTRACTOR SHALL COORDINATE INSTALLATION WITH MANUFACTURER

REPRESENTATIVE INSPECTIONS REQUIRED FOR WARRANTY ISSUANCE.

PROTECT ROOF SYSTEM FROM DAMAGE CAUSED BY OTHER TRADES.

REVISIONREVISION DATEDATE

NOTES:NOTES:

THIS DRAWING SHALL NOT BE

REPRODUCED, PLUBLISHED, OR USED

IN ANY WAY WITHOUT THE WRITTEN

PERMISSION OF THE ARCHITECT.

PROJECT NO.PROJECT NO.

DATEDATE

DRAWN BYDRAWN BY

CHECKED BYCHECKED BY

Roof Restoration at Scales

Elementary School

2340 St Andrews Dr Murfreesboro, TN 37128

05-26-26

K.S.P.

J.B.A.

A5.2

SCALE 1/16" = 1'-0"

ROOF PREPARATION PLAN - PART B

ROOF PREPARATION KEYNOTE LEGEND

1 REMOVE EXISTING ROOF DRAIN BASKET AND RETAIN FOR REINSTALLATION. REMOVE EXISTING DRAIN CLAMPING RING

TAKING CARE NOT TO DAMAGE EXISTING DRAIN. FULLY CLEAN AND PREPARE ROOF DRAIN FOR INSTALLATION OF NEW FLUID APPLIED ROOF SYSTEM. REINSTALL CLAMPING RING AND BASKET AFTER APPLICATION OF LIQUID-APPLIED

ROOFING SYSTEM. SEE DETAIL 1/A5.4

2 PREPARE EXISTING PIPE PENETRATION FOR INSTALLATION OF NEW REINFORCED FLUID APPLIED ROOF SYSTEM.

REPLACE PIPE PENETRATION FLASHINGS WHERE DAMAGED.

3 REMOVE EXISTING SNAP-ON ROOF EDGE FASCIA COVER AND RETAIN FOR REINSTALLATION. REINSTALL EDGE FASCIA

AFTER APPLICATON OF LIQUID-APPLIED ROOFING SYSTEM. SEE DETAIL 2/A5.4

4 REMOVE EXISTING ROOF WALKWAY PADS. TAKE CARE NOT TO DAMAGE EXISTING EPDM MEMBRANE. REPAIR ANY DAMAGE TO EPDM MEMBRANE AND PREPARE SURFACE FOR INSTALLATION OF NEW LIQUID-APPLIED MEMBRANE.

5 REPAIR FLASHING AT ROOF-TO WALL TRANSITION WHERE DAMAGED. PREPARE FLASHINGS FOR INSTALLATION OF

NEW FLUID APPLIED ROOF SYSTEM.

6 REPAIR FLASHING AT SKYLIGHT CURBS WHERE DAMAGED. PREPARE FLASHINGS FOR INSTALLATION OF NEW FLUID

APPLIED ROOF SYSTEM.

7 REPAIR FLASHING AT EXISTING MECHANICAL EQUIP. CURBS WHERE DAMAGED. PREPARE FLASHINGS FOR

INSTALLATION OF NEW FLUID APPLIED ROOF SYSTEM.

O.A.I.

E.F.

E.F.

E.F.

E.F.

O.A.I.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

C.A.

E.F.

E.F.

O.A.I.

E.F.

V.T.R. V.T.R.

O.A.I.

O.A.I.O.A.I.

O.A.I.O.A.I.O.A.I.

O.A.I.O.A.I.

E.F.

E.F. E.F.

E.F.

V.T.R.

V.T.R.

O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

V.T.R.

V.T.R.

V.T.R. V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I.

O.A.I.O.A.I.

E.F. E.F.

E.F.

E.F.

E.F.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

V.T.R.

V.T.R.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

E.F.

E.F.

E.F.

V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I.

O.A.I.O.A.I.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

E.F.

GENERAL ROOF RESTORATION NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS INCLUDING

SPECIFICATIONS PRIOR TO BIDDING AND CONSTRUCTION.

EXISTING ROOF IS EPDM MEMBRANE OVER RIGID INSULATION AND METAL ROOF

DECK. CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO COMMENCEMENT OF

WORK.

PERFORM INFRARED MOISTURE SCAN OF ENTIRE ROOF PRIOR TO INSTALLATION OF

RESTORATION SYSTEM. REMOVE AND REPLACE WET INSULATION AND DAMAGED

MEMBRANE AS REQUIRED.

ALL ROOF SURFACES SHALL BE CLEAN, DRY, AND FREE OF DEBRIS, OILS, AND

CONTAMINANTS PRIOR TO INSTALLATION OF FLUID-APPLIED MEMBRANE SYSTEM.

REPAIR ALL CUTS, PUNCTURES, BLISTERS, AND OPEN SEAMS IN EXISTING EPDM

PRIOR TO APPLICATION OF RESTORATION SYSTEM.

CONTRACTOR SHALL COORDINATE WORK TO MAINTAIN WEATHER-TIGHT CONDITIONS

AT ALL TIMES.

FLUID-APPLIED ROOFING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER’S WRITTEN REQUIREMENTS AND PROJECT SPECIFICATIONS.

ALL ROOF PENETRATIONS, CURBS, DRAINS, AND TRANSITIONS SHALL RECEIVE

REINFORCED COATING AND FABRIC DETAILING.

PROTECT ROOFTOP EQUIPMENT, WALLS, AND ADJACENT SURFACES FROM

OVERSPRAY AND COATING MATERIALS.

PROVIDE TEMPORARY PROTECTION OF ROOF AREAS NOT COMPLETED AT THE END

OF EACH WORKDAY.

CONTRACTOR SHALL COORDINATE INSTALLATION WITH MANUFACTURER

REPRESENTATIVE INSPECTIONS REQUIRED FOR WARRANTY ISSUANCE.

PROTECT ROOF SYSTEM FROM DAMAGE CAUSED BY OTHER TRADES.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

ROOF RESTORATION LEGEND

AREA OF ROOF RESTORATION

ROOF RESTORATION AREA SUMMARY

ROOF RESTORATION AREA: 135,000 SF

EXISTING ROOFING: EPDM MEMBRANE

RESTORATION SYSTEM: REINFORCED FLUID-APPLIED SYSTEM

NEW COATING WALKWAYS

WALKWAY SYSTEM REQUIREMENTS

THICKNESS: 120 MIL DFT WITH ADDITIONAL LAYER REINFORCING FABRIC

WIDTH: 30 IN MIN.

CONTRASTING COLOR: GREY

RESTORATION SYSTEM: REINFORCED FLUID-APPLIED SYSTEM

REVISIONREVISION DATEDATE

NOTES:NOTES:

THIS DRAWING SHALL NOT BE

REPRODUCED, PLUBLISHED, OR USED

IN ANY WAY WITHOUT THE WRITTEN

PERMISSION OF THE ARCHITECT.

PROJECT NO.PROJECT NO.

DATEDATE

DRAWN BYDRAWN BY

CHECKED BYCHECKED BY

Roof Restoration at Scales

Elementary School

2340 St Andrews Dr Murfreesboro, TN 37128

05-26-26

K.S.P.

J.B.A.

A5.3

SCALE 1/16" = 1'-0"

NEW WORK ROOF PLAN - PART A

ROOF RESTORATION KEYNOTE LEGEND

1 REINFORCE PIPE PENETRATIONS WITH BASE COAT AND FABRIC

2 REINFORCE MECHANICAL CURB FLASHINGS WITH BASE COAT AND FABRIC

3 REINFORCE ROOF DRAINS WITH BASE COAT AND FABRIC. REINSTALL ROOF DRAIN BASKET

AFTER COMPLETION OF ROOF RESTORATION. SEE DETAIL 1/A5.4

4 REINFORCE BUILDING EXPANSION JOINTS BASE COAT AND FABRIC.

5 REINFORCE SKYLIGHT CURB FLASHINGS WITH BASE COAT AND FABRIC

6 REINFORCE ROOF-TO-WALL FLASHINGS WITH BASE COAT AND FABRIC

O.A.I.

E.F.

E.F.

E.F.

E.F.

O.A.I.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

O.A.I.

E.F.

O.A.I.

E.F.

E.F.

V.T.R.

V.T.R.

V.T.R.

V.T.R.

C.A.

E.F.

E.F.

O.A.I.

E.F.

V.T.R. V.T.R.

O.A.I.

O.A.I.O.A.I.

O.A.I.O.A.I.O.A.I.

O.A.I.O.A.I.

E.F.

E.F. E.F.

E.F.

V.T.R.

V.T.R.

O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

V.T.R.

V.T.R.

V.T.R. V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I. O.A.I.

O.A.I. O.A.I.

O.A.I.O.A.I.

E.F. E.F.

E.F.

E.F.

E.F.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

V.T.R.

V.T.R.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

O.A.I.

E.F.

E.F.

E.F.

V.T.R.

V.T.R.

E.F.

E.F.

O.A.I. O.A.I.

O.A.I.O.A.I.

V.T.R.

V.T.R.

O.A.I.O.A.I.O.A.I.

O.A.I. O.A.I. O.A.I.

E.F.

E.F.

GENERAL ROOF RESTORATION NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS INCLUDING

SPECIFICATIONS PRIOR TO BIDDING AND CONSTRUCTION.

EXISTING ROOF IS EPDM MEMBRANE OVER RIGID INSULATION AND METAL ROOF

DECK. CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO COMMENCEMENT OF

WORK.

PERFORM INFRARED MOISTURE SCAN OF ENTIRE ROOF PRIOR TO INSTALLATION OF

RESTORATION SYSTEM. REMOVE AND REPLACE WET INSULATION AND DAMAGED

MEMBRANE AS REQUIRED.

ALL ROOF SURFACES SHALL BE CLEAN, DRY, AND FREE OF DEBRIS, OILS, AND

CONTAMINANTS PRIOR TO INSTALLATION OF FLUID-APPLIED MEMBRANE SYSTEM.

REPAIR ALL CUTS, PUNCTURES, BLISTERS, AND OPEN SEAMS IN EXISTING EPDM

PRIOR TO APPLICATION OF RESTORATION SYSTEM.

CONTRACTOR SHALL COORDINATE WORK TO MAINTAIN WEATHER-TIGHT CONDITIONS

AT ALL TIMES.

FLUID-APPLIED ROOFING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER’S WRITTEN REQUIREMENTS AND PROJECT SPECIFICATIONS.

ALL ROOF PENETRATIONS, CURBS, DRAINS, AND TRANSITIONS SHALL RECEIVE

REINFORCED COATING AND FABRIC DETAILING.

PROTECT ROOFTOP EQUIPMENT, WALLS, AND ADJACENT SURFACES FROM

OVERSPRAY AND COATING MATERIALS.

PROVIDE TEMPORARY PROTECTION OF ROOF AREAS NOT COMPLETED AT THE END

OF EACH WORKDAY.

CONTRACTOR SHALL COORDINATE INSTALLATION WITH MANUFACTURER

REPRESENTATIVE INSPECTIONS REQUIRED FOR WARRANTY ISSUANCE.

PROTECT ROOF SYSTEM FROM DAMAGE CAUSED BY OTHER TRADES.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

ROOF RESTORATION LEGEND

AREA OF ROOF RESTORATION

ROOF RESTORATION AREA SUMMARY

ROOF RESTORATION AREA: 135,000 SF

EXISTING ROOFING: EPDM MEMBRANE

RESTORATION SYSTEM: REINFORCED FLUID-APPLIED SYSTEM

NEW COATING WALKWAYS

WALKWAY SYSTEM REQUIREMENTS

THICKNESS: 120 MIL DFT WITH ADDITIONAL LAYER REINFORCING FABRIC

WIDTH: 30 IN MIN.

CONTRASTING COLOR: GREY

RESTORATION SYSTEM: REINFORCED FLUID-APPLIED SYSTEM

DRAIN BASKET

CLAMPING RING

TRIM EXISTING FLASHINGS TO

WHERE BOWL TURNS DOWN.

ENSURE NEW FLASHINGS FULLY

ENCAPSULATES OLD FLASHINGS.

EXTEND LIQUID APPLIED SYSTEM

INTO DRAIN

CAST IRON DRAIN BOWL - CLEAN TO

BRIGHT METAL AND PRIME

EXISTING INSULATION SUMP

EXISTING EPDM ROOF MEMBRANE

REINFORCED LIQUID APPLIED BASE

COAT

CUT REINFORCEMENT INTO TRIANGLES

AND OVERLAP INTO BOWL.

EXISTING SPRING CLIP TO REMAIN

SNAP-ON METAL FASCIA - REMOVE AND

RESINSTALL

LIQUID APPLIED TOP COAT

REINFORCED BASE COATS - EXTEND

UNDER SPRING CLIP

EXISTING EPDM ROOM

MEMBRANE

EXISTING INSULATION

EXISTING METAL

EDGE SYSTEM

REVISIONREVISION DATEDATE

NOTES:NOTES:

THIS DRAWING SHALL NOT BE

REPRODUCED, PLUBLISHED, OR USED

IN ANY WAY WITHOUT THE WRITTEN

PERMISSION OF THE ARCHITECT.

PROJECT NO.PROJECT NO.

DATEDATE

DRAWN BYDRAWN BY

CHECKED BYCHECKED BY

Roof Restoration at Scales

Elementary School

2340 St Andrews Dr Murfreesboro, TN 37128

05-26-26

K.S.P.

J.B.A.

A5.4

SCALE 1/16" = 1'-0"

NEW WORK ROOF PLAN - PART B

ROOF RESTORATION KEYNOTE LEGEND

1 REINFORCE PIPE PENETRATIONS WITH BASE COAT AND FABRIC

2 REINFORCE MECHANICAL CURB FLASHINGS WITH BASE COAT AND FABRIC

3 REINFORCE ROOF DRAINS WITH BASE COAT AND FABRIC. REINSTALL ROOF DRAIN BASKET

AFTER COMPLETION OF ROOF RESTORATION. SEE DETAIL 1/A5.4

4 REINFORCE BUILDING EXPANSION JOINTS BASE COAT AND FABRIC.

5 REINFORCE SKYLIGHT CURB FLASHINGS WITH BASE COAT AND FABRIC

6 REINFORCE ROOF-TO-WALL FLASHINGS WITH BASE COAT AND FABRIC

SCALE 12" = 1'-0"

ROOF DRAIN DETAIL1

SCALE 12" = 1'-0"

ROOF EDGE DETAIL2

0.0 - COVER
A5.1 - ROOF PREPARATION PLAN - PART A
A5.2 - ROOF PREPARATION PLAN - PART B
A5.3 - NEW WORK ROOF PLAN - PART A
A5.4 - NEW WORK ROOF PLAN - PART B, DETAILS

File details come from the government source that posted it. Updated .