Rock Cut State Park - Vendor Questions and Answers~1.docx

DOCX document 8 MB Posted

Attached to
DNR Rock Cut - Install Siding and Replacing Man Doors at CWD Building
Solicitation number
22-422DNR-REALT-B-24594
Issued by
Rock Island County, Illinois

About this file

This document is a set of questions and answers related to a Small Purchase Procurement Scope of Work and Project Requirements issued by the Illinois Department of Natural Resources for a project to Replace Siding and Man Doors at the CWD Building in Rock Cut State Park. The key details include:

The existing doors are 36" W x 80" H, and the scope specifies replacing them with two 3-ft x 7-ft commercial doors with a revised rough opening of 40" W x 88" H. The electrical conduits around the door openings need to be re-routed to accommodate the new commercial doors. The half columns attached to the building must also be covered with metal siding.

The document addresses clarifying questions related to the door size and openings. The new doors need to be the same size as the existing ones being replaced, and the rough opening does not need to be increased from 38" W x 82" H to 40" W x 88" H. The support columns attached to the building must be covered in metal siding.

View the file

Other files

File Type Posted
1Standard Terms and Conditions1~39.pdf PDF
Forms B 1~35.docx DOCX document
Location map and site photos~1.pdf PDF
SOW - Small~4.docx DOCX document
Standard CertificationsV.18.1~99.doc DOC document
1SMALL CONSTRUCTION BID FORM~54.docx DOCX document
Existing Building Details~1.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ILLINOIS DEPARTMENT OF NATURAL RESOURCES

SMALL PURCHASE PROCUREMENT

SCOPE OF WORK & PROJECT REQUIREMENTS

Date: September 23, 2021

ENG122004

LOCATION: Rock Cut State Park – CWD Building

PROJECT TITLE: Replace Siding and Man Doors

QUESTIONS:

1) The Two existing Doors are 36” W x 80” H, the current Scope specifies to replace with Two Commercial Doors, 3-ft x 7-ft. R.O. will be 40” W x 88” H. There are Electrical conduits around the Door Openings, shall the electrical work be re-routed to accommodate the Commercial Doors?

The replacement doors need to be the same size as those being replaced.

2) Shall the R.O. for the Doors to be increased from 38” W x 82” H to 40” W x 88” H?

The new R.O. needs to be the same size as the one being replaced.

3) Do the half columns that are attached to the Building need to be covered with Metal Siding?

Yes. The support columns need to be covered in metal siding.