This document is a Lead Inspection Report prepared by PbO3 Environmental Monitoring, LLC for the City of Ocala's Community Development Services Department, focusing on a residential property located at 812 NW 2nd St. in Ocala, Florida. The report details a comprehensive lead-based paint inspection and risk assessment conducted on May 27, 2025, utilizing X-ray fluorescence (XRF) testing to detect lead concentrations on various building components. Out of 223 total samples tested, 5 were found to be positive for lead-based paint, specifically on exterior window trim and roof soffits, with lead concentrations ranging from 1.2 to 1.9 mg/cm².
The report includes detailed soil sampling results, which showed a composite soil sample of 55 ug/g, falling below the EPA's recommended action level of 400 PPM for children's play areas. The document provides extensive guidance on potential lead abatement options, including removal, stripping, encapsulation, and enclosure, along with recommendations for dust and soil remediation. The report emphasizes the importance of proper testing, containment, and cleaning procedures to mitigate potential lead exposure risks, and includes a comprehensive glossary of technical terms related to lead-based paint hazard assessment and management.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pb 3 Environmental Monitoring, LLC.
6548 SW 131st Place Ocala, Florida 34473
Asbestos, Lead Paint and Construction Air Monitoring Consulting Bulk Sampling for Laboratory Analysis
(352) 203-4081 email: robpbo3@gmail.com or rrasmussen72@gmail.com
6548 SW 131st Place Ocala, FL 34473 OFFICE 352-203-4081
June 5, 2025
Client: City of Ocala Community Development Services Department 201 SE 3rd St.
Ocala, FL 34471
Project: LEAD - BASED PAINT INSPECTION & RISK ASSESSMENT REPORT Louise West 812 NW 2nd St.
Ocala, FL 34475
According to your instructions PbO3 Environmental Monitoring, LLC. has completed a LEAD-BASED PAINT INSPECTION & RISK ASSESSMENT REPORT of the subject property. The following pages of this report contain the results of this Inspection.
This report is intended for the exclusive use of our client under the terms and conditions of our agreement. The findings are relevant to the conditions observed during the physical process of performing the Inspection. These findings should not be treated as absolute, nor should they be relied upon to represent conditions at significantly later dates. Any other use, reuse, in whole or in part without the expressed written permission of PbO3 Environmental Monitoring, LLC. is strictly forbidden.
PbO3 Environmental Monitoring, LLC.
Robert Rasmussen Risk Assessor
Exhibit E - Lead Inspection Report Contract# CDS/250739
E - 1
LEAD - BASED PAINT INSPECTION & RISK ASSESSMENT REPORT
Louise West 812 NW 2nd St.
Ocala, FL 34475
PbO3 ENVIRONMENTAL MONITORING, LLC 352-203-4081 U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
TABLE OF CONTENTS
Table of Contents
1. SUMMARY of FINDINGS
2. REPORT
Methodology Used
APPENDIX A
LEAD SURVEY DATA PAGES
APPENDIX B
LABORATORY RESULTS
APPENDIX C
PHOTOS & DRAWINGS
APPENDIX D
LEAD PRECAUTIONARY PROCEDURES
APPENDIX E
COMMON TERMS FOR COMPONENTS AND TESTING LAYOUT
APPENDIX F
LEAD PAINT ABATEMENT OPTIONS:
E - 2
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
1. SUMMARY of FINDINGS
According to your instructions PbO3 Environmental Monitoring, LLC. of 6548 SW 131st Place Ocala, Florida has completed a LEAD-BASED PAINT INSPECTION & RISK ASSESSMENT of the subject property. The inspection was conducted on May 27, 2025. The Inspection was performed by Julian Spadt, Lead Risk Assessor(s) (certifications on file). This lead-based paint inspection did not include such items as water sampling, soils, mini blinds, lead dust analysis, furniture, bathroom and/or floor tile-except as noted in this report. Non-painted components, such as ceramic tile and vinyl baseboards, were not tested. Factory finish components or paneled areas such as walls, vent covers, countertops, exhaust hood covers, mailboxes, sinks, electrical panels, closet clothing bars, and light fixtures, etc., were not tested unless they were painted.
Ceramic Tile may be a Lead Containing Material such as that found in many Ceramic Tile glazes. Secondary Coverings such as drop ceilings, paneling, vinyl siding, wallpaper, furniture, clutter, etc. may conceal painted components, which were not accessible during this inspection. Care must be taken not to disturb concealed components unless it is determined that they do not contain lead-based paint.
The data in this report represents the entire scope of services for this Inspection. Conclusions drawn or opinions formed by others from this data are their own, and shall in no way obligate PbO3 Environmental Monitoring, LLC.
To the best of our knowledge and belief, the data contained herein is true and correct as represented. However, this should not be considered an undertaking where lead hazards are identified nor should any warranty, or guarantee, of suitability be assumed.
When evaluating this report, it is assumed as per HUD’s “Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing”, Chapter 7, that if one testing combination (ex: living room/window sill/wood) in an interior or exterior room equivalent is found to be positive for lead-based paint, then all other similar testing combinations in that room equivalent are also assumed to be positive for lead-based paint. The exception to this assumption is when 100% of the similar testing combinations in the room equivalent are tested.
Summary of the Findings
Test Method Performed No. of Samples No. above Action Level and/or Positive
No. below Action Level and/or Negative
X-ray Fluorescence 223 5 218
Notes:
All interior windows components are unpainted wood.
Room 2-All walls are unpainted wood.
E - 3
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Results
The Lead Inspection of the subject property showed that LEAD-BASED PAINT (LBP) (as defined in Title X of the 1992 Housing and Community Development Act - equal to or greater than 1.0 mg/cm2) was found in the following sample locations tested.
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
411 5/27/2025 12:13 WINDOW TRIM WOOD EXT A WHITE INTACT EXTERIOR Positive 1.9
420 5/27/2025 12:20 ROOF SOFFIT WOOD EXT A GRAY INTACT EXTERIOR Positive 1.4
433 5/27/2025 12:27 ROOF SOFFIT WOOD EXT B GRAY INTACT EXTERIOR Positive 1.8
445 5/27/2025 12:34 ROOF SOFFIT WOOD EXT C GRAY INTACT EXTERIOR Positive 1.2
460 5/27/2025 12:42 ROOF SOFFIT WOOD EXT D GRAY INTACT EXTERIOR Positive 1.5
Laboratory Results for Potential Lead Hazards - Dust Wipes and/or Soil Samples
Type of Surface
Sample # Sample Location Concentration (ug/ft2) or PPM
Sample Type
Result
Soil 812-L-01 Exterior Side A, B, C & D 55 ug/g Composite Passed
Revised Dust-Lead Hazard Standards (DLHS) as of January 06, 2020;
Current Action Levels for lead in dust: Interior Floor 10 ug/ft2 Porch Floor >40ug/ft2 Windowsill 100 ug/ft2 Troughs 100 ug/ft2 Current Action Level Soil for children play areas Greater than 400 PPM
Lead-Based Paint Hazards Detected LBP Dust Hazards were not detected.
Summary Exterior Side A-Window Trim is positive for Lead-Based Paint.
Exterior soffit is positive for Lead-Based Paint.
Conclusion
We can conclude that LEAD-BASED PAINT (as defined in Title X of the 1992 Housing and Community Development Act -equal to or greater than 1.0 mg/cm2) was detected.
Some painted surfaces may contain levels of lead below 1.0 mg/cm2, which could create lead dust or lead-contaminated soil hazards (Lead-Based Paint Hazard) if the paint is turned into dust by abrasion, scraping, or sanding (refer to XRF Results).
Lead-Based Paint Hazard: A condition in which exposure to lead-contaminated dust, lead-contaminated soil, or deteriorated lead-based paint would have an adverse effect on human health (as established the EPA Administrator under Title IV of the toxic Substance Control Act). Lead-based paint hazards include for example, deteriorated lead-based paint, leaded dust levels above applicable standards, and bare leaded soils above applicable standards. Some painted surfaces may contain levels of lead below 1.0 mg/cm2, which could create lead dust or lead-contaminated soil hazards if the paint is turned into dust by abrasion, scraping, or sanding. This report should be kept by the owner and all future owners for the life of the dwelling.
E - 4
Recommendations (when lead based paints are found)
Conduct interim controls in accordance with 24 CFR Part 35 (§ 35.1330) to treat the lead-based paint hazards identified in this report. Interim controls are considered completed when clearance is achieved in accordance with § 35.1340. Interim controls of all lead-based paint hazards shall be completed no later than the following schedule: (a) In units occupied by families with children of less than 6 years of age, interim controls shall be completed no later than 90 days after the completion of the risk assessment. In units in which a child of less than 6 years of age moves in after the completion of the risk assessment, interim controls shall be completed no later than 90 days after the move-in. (b) units not occupied by families with children under 6 years of age, shall have interim controls completed within 12 months of the completion of the risk assessment for those units.
Interim Controls
Interim controls of lead-based paint hazards identified in a risk assessment shall be conducted in accordance with the provisions of this section. Interim control measures include paint stabilization of deteriorated paint, treatments for friction and impact surfaces where levels of lead dust are above the levels specified, dust control, and lead-contaminated soil control.
Revised Dust-Lead Hazard Standards (DLHS) as of January 06, 2020;
Current Action Levels for lead in dust: Interior Floor 10 ug/ft2 Porch Floor >40ug/ft2 Windowsill 100 ug/ft2 Troughs 100 ug/ft2 Current Action Level Soil for children play areas Greater than 400 PPM
Interim controls may be performed in combination with, or be replaced by, abatement methods.
(2) Occupants of dwelling units where interim controls are being performed shall be protected during the course of the work.
Residents must not be in the area being cleaned.
(3) Clearance testing shall be performed at the conclusion of interim control activities.
(4) A person performing interim controls must be trained in accordance with the hazard communication standard for the construction industry issued by the Occupational Safety and Health Administration of the U.S. Department of Labor at 29 CFR 1926.59, and either be supervised by an individual certified as a lead-based paint abatement supervisor or have completed successfully one of the following lead-safe work practices courses, except that this supervision or lead-safe work practices training requirement does not apply to work that disturbs painted surfaces less than the de minimis limits of 24 CFR Part 35.1350(d):
(i) A lead-based paint abatement supervisor course accredited in accordance with 40 CFR 745.225;
(ii) A lead-based paint abatement worker course accredited in accordance with 40 CFR 745.225; or
(iii) Another course approved by HUD for this purpose after consultation with the EPA. A current list of approved courses is available on the Internet at http://www.hud.gov/offices/lead, or by mail or fax from the HUD Office of Healthy Homes and Lead Hazard Control at (202) 755–1785, extension 104 (this is not a toll-free number). Persons with hearing or speech impediments may access the above telephone number via phone or TTY by calling the toll-free Federal Information Relay Service at (800) 877–8339.
(iv) “The Remodeler's and Renovator's Lead-Based Paint Training Program,” prepared by HUD and the National Association of the Remodeling Industry; or
(v) Another course approved by HUD for this purpose after consultation with EPA.
(b) Paint stabilization. (1) Interim control treatments used to stabilize deteriorated lead-based paint shall be performed in accordance with the requirements of this section. Interim control treatments of intact, factory applied prime coatings on
E - 5
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890 metal surfaces are not required. Finish coatings on such surfaces shall be treated by interim controls if those coatings contain lead-based paint.
(2) Any physical defect in the substrate of a painted surface or component that is causing deterioration of the surface or component shall be repaired before treating the surface or component. Examples of defective substrate conditions include dry-rot, rust, moisture-related defects, crumbling plaster, and missing siding or other components that are not securely fastened.
(3) Before applying new paint, all loose paint and other loose material shall be removed from the surface to be treated.
Acceptable methods for preparing the surface to be treated include wet scraping, wet sanding, and power sanding performed in conjunction with a HEPA filtered local exhaust attachment operated according to the manufacturer's instructions.
(4) Dry sanding or dry scraping is permitted only in accordance with 24 CFR 35.140(e) (i.e., for electrical safety reasons or for specified minor amounts of work).
(5) Paint stabilization shall include the application of a new protective coating or paint. The surface substrate shall be dry and protected from future moisture damage before applying a new protective coating or paint. All protective coatings and paints shall be applied in accordance with the manufacturer's recommendations.
(6) Paint stabilization shall incorporate the use of safe work practices in accordance with 24 CFR 35.1350.
(c) Friction and impact surfaces. (1) Friction surfaces are required to be treated only if:
(i) Lead dust levels on the nearest horizontal surface underneath the friction surface (e.g., the windowsill, window trough, or floor) are equal to or greater than the standards.
(ii) There is evidence that the paint surface is subject to abrasion; and
(iii) Lead-based paint is known or presumed to be present on the friction surface.
(2) Impact surfaces are required to be treated only if:
(i) Paint on an impact surface is damaged or otherwise deteriorated.
(ii) The damaged paint is caused by impact from a related building component (such as a doorknob that knocks into a wall, or a door that knocks against its door frame); and
(iii) Lead-based paint is known or presumed to be present on the impact surface.
(3) Examples of building components that may contain friction or impact surfaces include the following:
(i) Window systems;
(ii) Doors;
(iii) Stair treads and risers;
(iv) Baseboards;
(v) Drawers and cabinets; and
(vi) Porches, decks, interior floors, and any other painted surfaces that are abraded, rubbed, or impacted.
(4) Interim control treatments for friction surfaces shall eliminate friction points or treat the friction surface so that paint is not subject to abrasion. Examples of acceptable treatments include rehanging and/or plaining doors so that the door does not rub against the door frame, and installing window channel guides that reduce or eliminate abrasion of painted surfaces.
E - 6
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Paint on stair treads and floors shall be protected with a durable cover or coating that will prevent abrasion of the painted surfaces. Examples of acceptable materials include carpeting, tile, and sheet flooring.
(5) Interim control treatments for impact surfaces shall protect the paint from impact. Examples of acceptable treatments include treatments that eliminate impact with the paint surface, such as a door stop to prevent a door from striking a wall or baseboard.
(6) Interim control for impact or friction surfaces does not include covering such a surface with a coating or other treatment, such as painting over the surface that does not protect lead-based paint from impact or abrasion.
(d) Chewable surfaces. (1) Chewable surfaces are required to be treated only if there is evidence of teeth marks, indicating that a child of less than six years of age has chewed on the painted surface, and lead-based paint is known or presumed to be present on the surface.
(2) Interim control treatments for chewable surfaces shall make the lead-based paint inaccessible for chewing by children of less than 6 years of age. Examples include enclosures or coatings that cannot be penetrated by the teeth of such children.
(e) Dust-lead hazard control. (1) Interim control treatments used to control dust-lead hazards shall be performed in accordance with the requirements of this section. Additional information on dust removal is found in the HUD Guidelines, particularly Chapter 11.
(2) Dust control shall involve a thorough cleaning of all horizontal surfaces, such as interior windowsills, window troughs, floors, and stairs, but excluding ceilings. All horizontal surfaces, such as floors, stairs, windowsills and window troughs, that are rough, pitted, or porous shall be covered with a smooth, cleanable covering or coating, such as metal coil stock, plastic, polyurethane, or linoleum.
“A copy of this summary must be provided to new lessees (tenants) and purchasers of this property under Federal law (24 CFR part 35 and 40 CFR part 745) before they become obligated under a lease or sales contract. The complete report must also be provided to new purchasers, and it must be made available to new tenants. Landlords (lessors) and sellers are also required to distribute an educational pamphlet approved by the U.S. Environmental Protection Agency and include standard warning language in their leases or sales contracts to ensure that parents have information they need to protect their children form lead-based paint hazards” 1
1 U.S. Department of Housing and Urban Development – “Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing”- Chapter 7
E - 7
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
2. REPORT
Purpose
The purpose of this Inspection is to identify and determine the presence or absence of lead-based paint as defined by The U.S. Department Of Housing And Urban Development publication “The Guidelines For The Evaluation And Control Of Lead
- Based Paint Hazards in Housing” June 1995. “The Guidelines” were developed pursuant to Section 1017 of Title X, the Residential Lead Based Paint Hazard Reduction Act of 1992, requiring the EPA to develop health- based standards for paint, dust, and soil.
Definition of “Lead - Based Paint Hazard”
Title X redefines the concept of "lead-based paint." Under prior Federal legislation, a lead-based paint was any paint with
1.0 mg/cm2 or more of lead, regardless of paint condition or location. Title X states that a lead-based paint hazard is "any condition that causes exposure to lead . . . that would result in adverse human health effects" from:
• Lead-contaminated dust
• Bare, lead-contaminated soil
• Lead-contaminated paint that is deteriorated or present on accessible surfaces, friction surfaces, or impact surfaces.
Title X acknowledges that some lead-based paint hazards are of more immediate concern than others. In these Guidelines the hazards considered to be of greatest immediate concern are those to which children are most exposed: lead-contaminated dust; deteriorated lead-based paint; and lead-contaminated soil if it is bare, accessible to young children, and/or likely to be blown or tracked into the dwelling. Also of concern is friction, chewable, and impact surfaces with intact lead-based paint. Friction surfaces are subject to abrasion and may generate lead-contaminated dust in the dwelling;
chewable surfaces are protruding surfaces that are easily chewed on by young children; and impact surfaces may become deteriorated through forceful contact. Intact lead-based paint on flat surfaces not subject to abrasion, impact, or other disturbances, although of less concern, is still a potential hazard because the paint could deteriorate over time as a result of age, disturbance (through renovation and repair) or major casualty (such as fire, storms, and water leaks).
Lead - based paint is any paint, varnish, stain, or other applied coating that has 1 mg/cm² (or 5,000 parts per million) or more of lead. For the purposes of these Guidelines the terms "leaded paint" and "lead-containing paint" are synonymous with "lead-based paint".
A lead - based paint hazard may be interpreted by environmental sampling for lead dust. If lead dust samples collected by wipe sampling exceed the levels established by HUD, a lead - based paint hazard exists.
Lead Testing Methods
Lead-Based Paint, X-Ray Fluorescence (XRF)
XRF testing is performed to detect the presence of lead on painted surfaces. XRF testing is usually the preferred method of testing because it is non-destructive, quantitative and can be performed on the spot with acceptable accuracy. The results of the XRF testing is one of the major sources of gathering evidence for drawing conclusions and making recommendations in the final report.
PbO3 Inspectors follow the manufacturer’s suggested use and the Performance Characteristic Sheet of the XRF instrument being used. PbO3 currently uses the NITON XL Spectrum Analyzer with automatic substrate correction, software downloading capabilities, 3/8-inch penetration capabilities, and many more sophisticated advantages.
E - 8
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
In performing XRF testing all PbO3 Inspectors follow the Department of Housing and Urban Developments federal guidelines for testing lead by using an XRF instrument. All state and city regulations are followed when applicable and, in all cases, the most stringent regulation is followed. PbO3 Inspectors test one of each and every different type of accessible testing combination in each room being inspected or as described in our client services agreement. Testing procedures for XRF testing are usually performed from left to right by room and within each room left to right by component. The testing format is followed unless otherwise noted. Each XRF reading is assigned an exclusive reference number and a measurement that is stored in the instrument. Each reference number location is logged on the data sheets for future reference, testing location and report generation.
Current action levels for lead based paint testing using XRF vary from state to state. The federal level is currently 1.0 mg/cm2.
See Appendix A for LEAD PAINT INSPECTION REPORT DATA SHEETS for measurement, location, substrate, and surfaces tested.
Dust Wipes
Dust wipes are taken after the initial inspection (if applicable), to determine current levels of lead dust (Risk Assessment), during interim controls (regularly scheduled sampling), or after an abatement activity to determine the post abatement levels.
Dust wipes are typically taken from three different places: Floor, Window Troughs and Windowsills. The lead dust levels will determine if a Lead Hazard exists and will help in the decision-making process as to what forms of interim controls are needed.
Lead, like iron, oxidizes, though when iron oxidizes it forms rust, and when lead oxidizes it will form lead carbonate. Some people call the lead carbonate “chalking” of the lead. Inhaling or ingesting lead carbonate can be as dangerous as eating a lead paint chip. Most people are unaware that a small child does not have to eat paint chips to acquire an elevated blood lead level (EBL). The hand-to-mouth activity of a crawling child in an area with lead dust can induce Lead Poisoning. Lead dust problems can also place the occupants and participants at risk during renovation and/or construction activities.
PbO3 believes that high lead dust levels pose a greater health threat, than the mere presence of intact lead-based paint.
Consequently, we strongly suggest regularly scheduled monitoring by lead dust wipes, until full abatement is completed.
Revised Dust-Lead Hazard Standards (DLHS) as of January 06, 2020;
Current Action Levels for lead in dust: Interior Floor 10 ug/ft2 Porch Floor >40ug/ft2 Windowsill 100 ug/ft2 Troughs 100 ug/ft2 Current Action Level Soil for children play areas Greater than 400 PPM
Soil
Soil samples are usually taken after the initial inspection (if applicable), to determine the current level of lead in the soil and after any exterior abatement (including pressure washing) or renovation activities have taken place. PbO3 Inspectors take the soil samples from the side of a property and other areas of concern that are most likely to have a possible elevated lead level. A typical soil sample is collected by taking multiple spoonful’s of soil from one side of a piece of property typically along a straight line and a half-inch deep. By performing our sampling in this fashion, we are acquiring a representative sample from a specific side of the property.
EPA recommends the following action levels for lead in soil.
Action Level Children play areas Greater than 400 PPM Interim controls.
Non-children play areas Greater than 2000 PPM Interim controls.
All areas of exposed soil Greater than 5000 PPM Permanent Barrier or Abatement.
E - 9
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Paint Chips
Paint chips are used for confirmation of lead-based paint as part of an inspection (if applicable), or as a solution to inconclusive measurement recorded by the use of XRF testing. Paint chips are typically not taken unless absolutely necessary. Every time a paint chip is taken the painted surface must be disturbed, and this leaves the potential for additional lead contamination. When Paint chips are taken, they are usually from non-conspicuous areas and tape is placed over the removed paint location. The paint chips are then sent to the laboratory for analysis.
Current action levels for lead in paint:
0.5% by weight or 5,000 PPM (parts per million) Weighted concentration
1.0 mg/cm2 Loading concentration (by XRF)
See summary results for chips, wipes, soil & water (if applicable).
Water
Water samples are collected to determine if lead is present in the water system. Two water samples are usually collected, a first draw and a two-minute draw. The first draw is the first draw of the day; it allows for the longest duration of time to allow any sediment in the water lines to collect and typically, if lead is present in the system, gives the highest results. The second sample is drawn after the cold-water tap has been turned on for two minutes. The second draw allows the tap time to flush itself from any particles that might have accumulated while the line was dormant. By taking two samples PbO3 Inspectors are better able to assess if there is possible water contamination due to lead and where it might be coming from.
If the first draw is high and the second draw is low, it probably means that the lead is coming from the property’s plumbing.
If both samples produce high levels, the problem is probably coming from the municipal water lines or both.
Current action levels for lead in water:
15 to 20 ppb (parts per billion)
See summary results for chips, wipes, soil & water (if applicable).
Methodology Used
This Inspection has been conducted utilizing an established protocol. The protocol contains four components.
1. Perform a visual assessment of the subject property and paint condition.
2. Calibrate Niton XL XRF # 92540
3. Test building components.
All room equivalents (e.g., room, house exterior, foyer, etc.) are tested. All testing combinations within each room equivalent are tested. All painted surfaces (surfaces coated with paint, shellac, varnish, stain, paint covered with wallpaper, or any other coating) are tested.
At least one XRF reading on each testing combination in each room equivalent are tested. For walls, at least one reading on each wall in a room equivalent is tested.
Certain building components that are adjacent to each other and not likely to have different painting histories can be grouped together into a single testing combination, as follows:
Window casings, stops, jambs and aprons are a single testing combination.
E - 10
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Interior window mullions and window sashes are a single testing combination – we do not group interior mullion and sashes with exterior mullions and sashes.
Exterior window mullions and window sashes are a single testing combination.
Door jambs, stops, transforms, casings, and other door frame parts are a single testing combination.
Door stiles, rails, panels, mullions, and other door parts are a single testing combination.
Baseboards and associated trim, (such as quarter-round or other caps) are a single testing combination (do not group chair rails, crown molding or walls with baseboards).
Painted electrical sockets, switches or plates can be grouped with walls.
Each of these building parts should be tested separately if there is some specific reason to believe that they have a different painting history. In most cases, separate testing will not be necessary.
Building Component Types – A building component type consists of doors, windows, walls, and so on that are repeated in more than one room equivalent in a unit and have a common substrate. If a unique building component is present in only one room, it is considered to be a testing combination. Each testing combination may be composed of more than one building component (such as two similar windows within a room equivalent). Component types can be located inside or outside the dwelling. For example, typical component types in a bedroom would be the ceiling, walls, a door and its casing, the window sash, window casings, and any other distinct surface such as baseboards, crown molding, and chair rails. If trends or patterns of lead-based paint classifications are found among building component types in different room equivalents, an inspection report may summarize results by building component type, as long as all measurements are included in the report. For example, the inspection may find that all doors and casings in a dwelling unit are positive.
4. A compilation of the findings of the Inspection into a report format, which is usable to the client.
E - 11
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
APPROXIMATE COST ESTIMATES FOR REMEDIATION
The price estimates below are based on numerous assumptions and variables that are ever changing. The cost estimates are only estimates and should not be considered final and absolute costs to remediate the property inspected of any lead hazards found. PbO3 estimates are based on average industry prices for the median cost option for various components.
Dependent on the course of action the particular property uses to remediate, the price estimates may vary greatly from actual cost proposals.
Approximate abatement costs (per component):
*Above pricing includes the cost of post abatement cleanups.
Item Description No. of Items Cost per Item* Total Cost
Remove &replace Window/per window 400.00$ -$
Exterior Door/per door 500.00$ -$ Interior Door/per door 200.00$ -$
Exterior Siding/per Sq Ft 5.00$ -$
Interior enclosure/per Sq Ft 4.00$ -$
Exterior stripping/per Sq Ft 9.00$ -$
Interior Stripping/per Sq Ft 10.00$ -$
Replacement of molding/per LF 6.00$ -$
Exterior encapsulation/Sq Ft 4.50$ -$
Interior encapsulation/Sq Ft 3.00$ -$
HEPA vacuuming/Sq Ft 1.00$ -$
TSP or Ledizolv washing/Sq Ft 1.00$ -$
Total Estimated Costs -$
E - 12
APPENDIX A
LEAD SURVEY DATA PAGES
When reviewing “Appendix A Lead Survey Data Pages” you will notice that the components tested are described using the letters A, B, C and D, under the “Surface” column, to designate the walls of the related room. When entering the room, the first wall that is in the same plain or closest to the street address of the property is considered to be “A-wall”, “B-wall”, “C-wall”, and “D-wall” run clockwise.
Lead paint testing using XRF technology results are provided on the attached tables. Per this type of analytical methodology, XRF values tend to vary slightly for lead detected on the same surface, within the parameters of the instrumentation and the paint history of the testing combination. If a component is not shown on the data pages, the assumption should not be made that the particular component is lead safe. The only way to determine the presence of lead on a component is to have it tested.
Note: Negative values in Column mg/cm2 (PbC) are likely due to XRF interference and are typically not of concern unless more than 20% of the readings are negative.
E - 13
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
236 5/27/2025 11:14 CALIBRATE Positive 1.1
237 5/27/2025 11:14 CALIBRATE Positive 1.6
238 5/27/2025 11:14 CALIBRATE Negative 0
239 5/27/2025 11:15 WALL WALL PLASTER A WHITE INTACT 1 Negative 0.03
240 5/27/2025 11:15 WALL WALL WOOD B VARNISH INTACT 1 Negative 0.04
241 5/27/2025 11:16 WALL WALL PLASTER B WHITE INTACT 1 Negative 0.03
242 5/27/2025 11:16 WALL WALL WOOD C VARNISH INTACT 1 Negative 0.04
243 5/27/2025 11:16 WALL WALL PLASTER D WHITE INTACT 1 Negative 0.03
244 5/27/2025 11:18 DOOR CASING WOOD A RED INTACT 1 Negative 0.03
245 5/27/2025 11:18 DOOR CASING WOOD A RED INTACT 1 Negative 0.04
246 5/27/2025 11:19 DOOR DOOR METAL A RED INTACT 1 Negative 0.03
247 5/27/2025 11:19 DOOR CASING WOOD B VARNISH INTACT 1 Negative 0.03
248 5/27/2025 11:19 DOOR CASING WOOD B VARNISH INTACT 1 Negative 0.07
249 5/27/2025 11:19 DOOR CASING WOOD B VARNISH INTACT 1 Negative 0.05
250 5/27/2025 11:20 DOOR CASING WOOD B VARNISH INTACT 1 Negative 0.04
251 5/27/2025 11:20 TRIM WALL WOOD B WHITE INTACT 1 Negative 0.03
252 5/27/2025 11:20 DOOR CASING WOOD C VARNISH INTACT 1 Negative 0.04
253 5/27/2025 11:20 DOOR CASING WOOD C VARNISH INTACT 1 Negative 0.04
254 5/27/2025 11:21 DOOR CASING WOOD C VARNISH INTACT 1 Negative 0.03
255 5/27/2025 11:21 DOOR CASING WOOD C VARNISH INTACT 1 Negative 0.05
256 5/27/2025 11:21 BASEBOARD BASEBOARD WOOD C VARNISH INTACT 1 Negative 0.03
257 5/27/2025 11:22 CEILING WALL PLASTER C WHITE INTACT 1 Negative 0.03
258 5/27/2025 11:24 DOOR CASING WOOD C VARNISH INTACT 2 Negative 0.03
259 5/27/2025 11:24 DOOR CASING WOOD C VARNISH INTACT 2 Negative 0.03
260 5/27/2025 11:24 DOOR CASING WOOD C WHITE INTACT 2 Negative 0.03
261 5/27/2025 11:25 DOOR CASING WOOD C WHITE INTACT 2 Negative 0.03
262 5/27/2025 11:25 DOOR DOOR WOOD C VARNISH INTACT 2 Negative 0.03
263 5/27/2025 11:25 DOOR DOOR WOOD C VARNISH INTACT 2 Negative 0.03
264 5/27/2025 11:26 WALL UPPER TRIM WOOD C BROWN INTACT 2 Negative 0.03
265 5/27/2025 11:26 CEILING WALL PLASTER C WHITE INTACT 2 Negative 0.03
266 5/27/2025 11:27 WALL WALL PLASTER A WHITE INTACT 3 Negative 0.03
267 5/27/2025 11:27 WALL WALL PLASTER A WHITE INTACT 3 Negative 0.03
268 5/27/2025 11:27 WALL WALL WOOD C VARNISH INTACT 3 Negative 0.03
269 5/27/2025 11:27 WALL WALL WOOD D VARNISH INTACT 3 Negative 0.03
270 5/27/2025 11:28 WALL WALL PLASTER D WHITE INTACT 3 Negative 0.03
271 5/27/2025 11:28 WINDOW CASING WOOD B BLACK INTACT 3 Negative 0.03
272 5/27/2025 11:28 WINDOW CASING WOOD B BLACK INTACT 3 Negative 0.05
273 5/27/2025 11:29 WINDOW SILL WOOD B BLACK INTACT 3 Negative 0.03
274 5/27/2025 11:29 WINDOW SILL WOOD B BLACK INTACT 3 Negative 0.03
275 5/27/2025 11:29 WINDOW MULLION WOOD B BLACK INTACT 3 Negative 0.03
276 5/27/2025 11:29 WINDOW MULLION WOOD B BLACK INTACT 3 Negative 0.06
277 5/27/2025 11:30 DOOR CASING WOOD B WHITE INTACT 3 Negative 0.03
E - 14
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
278 5/27/2025 11:30 DOOR CASING WOOD B WHITE INTACT 3 Negative 0.03
279 5/27/2025 11:30 DOOR DOOR METAL B RED INTACT 3 Negative 0.03
280 5/27/2025 11:31 CLOSET WALL PLASTER C WHITE INTACT 3 Negative 0.07
281 5/27/2025 11:31 CLOSET CASING WOOD C VARNISH INTACT 3 Negative 0.03
282 5/27/2025 11:32 CLOSET DOOR WOOD C VARNISH INTACT 3 Negative 0.03
283 5/27/2025 11:32 CLOSET DOOR WOOD A VARNISH INTACT 3 Negative 0.06
284 5/27/2025 11:32 CLOSET CASING WOOD A VARNISH INTACT 3 Negative 0.05
285 5/27/2025 11:33 CLOSET WALL PLASTER A GREEN INTACT 3 Negative 0.05
286 5/27/2025 11:33 DOOR CASING WOOD D VARNISH INTACT 3 Negative 0.03
287 5/27/2025 11:33 DOOR CASING WOOD D VARNISH INTACT 3 Negative 0.05
288 5/27/2025 11:34 DOOR CASING WOOD D VARNISH INTACT 3 Negative 0.03
289 5/27/2025 11:34 DOOR CASING WOOD D VARNISH INTACT 3 Negative 0.04
290 5/27/2025 11:34 DOOR DOOR WOOD D VARNISH INTACT 3 Negative 0.06
291 5/27/2025 11:34 DOOR DOOR WOOD D VARNISH INTACT 3 Negative 0.04
292 5/27/2025 11:35 BASEBOARD BASEBOARD WOOD D WHITE INTACT 3 Negative 0.03
293 5/27/2025 11:35 CEILING WALL PLASTER D WHITE INTACT 3 Negative 0.03
294 5/27/2025 11:35 CEILING WALL PLASTER D WHITE INTACT 3 Negative 0.03
295 5/27/2025 11:36 WALL WALL PLASTER A WHITE INTACT 4 Negative 0.03
296 5/27/2025 11:37 WALL WALL PLASTER A WHITE INTACT 4 Negative 0.03
297 5/27/2025 11:37 WALL WALL PLASTER A WHITE INTACT 4 Negative 0.03
298 5/27/2025 11:37 WALL WALL PLASTER A WHITE INTACT 4 Negative 0.03
299 5/27/2025 11:37 WINDOW CASING WOOD B WHITE INTACT 4 Negative 0.03
300 5/27/2025 11:38 WINDOW SILL WOOD B WHITE INTACT 4 Negative 0.03
301 5/27/2025 11:38 DOOR CASING WOOD D WHITE INTACT 4 Negative 0.03
302 5/27/2025 11:38 DOOR CASING WOOD D WHITE INTACT 4 Negative 0.03
303 5/27/2025 11:39 DOOR CASING WOOD D VARNISH INTACT 4 Negative 0.03
304 5/27/2025 11:39 DOOR CASING WOOD D VARNISH INTACT 4 Negative 0.03
305 5/27/2025 11:39 DOOR DOOR WOOD D VARNISH INTACT 4 Negative 0.04
306 5/27/2025 11:39 DOOR DOOR WOOD D VARNISH INTACT 4 Negative 0.03
307 5/27/2025 11:39 BASEBOARD BASEBOARD WOOD D WHITE INTACT 4 Negative 0.03
308 5/27/2025 11:40 CEILING WALL PLASTER D WHITE INTACT 4 Negative 0.11
309 5/27/2025 11:41 WALL WALL PLASTER A WHITE INTACT 5 Negative 0.03
310 5/27/2025 11:41 WALL WALL PLASTER A WHITE INTACT 5 Negative 0.03
311 5/27/2025 11:41 WALL WALL PLASTER A WHITE INTACT 5 Negative 0.03
312 5/27/2025 11:41 WALL WALL PLASTER A WHITE INTACT 5 Negative 0.03
313 5/27/2025 11:42 WINDOW CASING WOOD B WHITE INTACT 5 Negative 0.03
314 5/27/2025 11:42 WINDOW SILL WOOD B WHITE INTACT 5 Negative 0.04
315 5/27/2025 11:42 DOOR CASING WOOD D WHITE INTACT 5 Negative 0.03
316 5/27/2025 11:42 DOOR CASING WOOD D WHITE INTACT 5 Negative 0.03
317 5/27/2025 11:43 DOOR CASING WOOD D WHITE INTACT 5 Negative 0.03
318 5/27/2025 11:43 DOOR CASING WOOD D VARNISH INTACT 5 Negative 0.05
319 5/27/2025 11:43 DOOR CASING WOOD D VARNISH INTACT 5 Negative 0.04
E - 15
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
320 5/27/2025 11:43 DOOR DOOR WOOD D VARNISH INTACT 5 Negative 0.06
321 5/27/2025 11:43 DOOR DOOR WOOD D VARNISH INTACT 5 Negative 0.04
322 5/27/2025 11:44 BASEBOARD BASEBOARD WOOD D WHITE INTACT 5 Negative 0.03
323 5/27/2025 11:44 CEILING WALL PLASTER D WHITE INTACT 5 Negative 0.03
324 5/27/2025 11:45 WALL WALL PLASTER A WHITE INTACT 6 Negative 0.03
325 5/27/2025 11:45 WALL WALL PLASTER A WHITE INTACT 6 Negative 0.03
326 5/27/2025 11:45 WALL WALL PLASTER A WHITE INTACT 6 Negative 0.03
327 5/27/2025 11:45 WALL WALL PLASTER A WHITE INTACT 6 Negative 0.03
328 5/27/2025 11:46 DOOR CASING WOOD A VARNISH INTACT 6 Negative 0.03
329 5/27/2025 11:46 DOOR CASING WOOD A VARNISH INTACT 6 Negative 0.03
330 5/27/2025 11:46 DOOR CASING WOOD A VARNISH INTACT 6 Negative 0.04
331 5/27/2025 11:46 DOOR CASING WOOD A VARNISH INTACT 6 Negative 0.04
332 5/27/2025 11:46 DOOR DOOR WOOD A VARNISH INTACT 6 Negative 0.03
333 5/27/2025 11:47 DOOR DOOR WOOD A VARNISH INTACT 6 Negative 0.04
334 5/27/2025 11:47 CLOSET WALL PLASTER D WHITE INTACT 6 Negative 0.03
335 5/27/2025 11:48 CLOSET CASING WOOD D VARNISH INTACT 6 Negative 0.03
336 5/27/2025 11:48 CLOSET DOOR WOOD D VARNISH INTACT 6 Negative 0.1
337 5/27/2025 11:48 CLOSET DOOR WOOD D VARNISH INTACT 6 Negative 0.03
338 5/27/2025 11:49 CLOSET CASING WOOD D VARNISH INTACT 6 Negative 0.03
339 5/27/2025 11:49 CLOSET WALL PLASTER D WHITE INTACT 6 Negative 0.03
340 5/27/2025 11:49 CEILING WALL PLASTER D WHITE INTACT 6 Negative 0.05
341 5/27/2025 11:50 BASEBOARD BASEBOARD WOOD D VARNISH INTACT 6 Negative 0.03
342 5/27/2025 11:50 WALL WALL PLASTER A WHITE INTACT 7 Negative 0.03
343 5/27/2025 11:51 WALL WALL PLASTER A WHITE INTACT 7 Negative 0.03
344 5/27/2025 11:51 WALL WALL PLASTER A WHITE INTACT 7 Negative 0.03
345 5/27/2025 11:51 WALL WALL PLASTER A WHITE INTACT 7 Negative 0.03
346 5/27/2025 11:52 DOOR CASING WOOD A VARNISH INTACT 7 Negative 0.04
347 5/27/2025 11:52 DOOR CASING WOOD A VARNISH INTACT 7 Negative 0.15
348 5/27/2025 11:52 DOOR CASING WOOD A VARNISH INTACT 7 Negative 0.05
349 5/27/2025 11:52 DOOR CASING WOOD A VARNISH INTACT 7 Negative 0.03
350 5/27/2025 11:52 DOOR DOOR WOOD A VARNISH INTACT 7 Negative 0.03
351 5/27/2025 11:52 DOOR DOOR WOOD A VARNISH INTACT 7 Negative 0.04
352 5/27/2025 11:53 CLOSET WALL PLASTER B WHITE INTACT 7 Negative 0.03
353 5/27/2025 11:53 CLOSET CASING WOOD B VARNISH INTACT 7 Negative 0.03
354 5/27/2025 11:54 CLOSET DOOR WOOD B VARNISH INTACT 7 Negative 0.05
355 5/27/2025 11:54 BASEBOARD BASEBOARD WOOD B VARNISH INTACT 7 Negative 0.03
356 5/27/2025 11:55 CEILING WALL PLASTER B WHITE INTACT 7 Negative 0.03
357 5/27/2025 11:55 WALL WALL PLASTER A GRAY INTACT 8 Negative 0.03
358 5/27/2025 11:56 WALL WALL PLASTER A RED INTACT 8 Negative 0.03
359 5/27/2025 11:56 WALL WALL PLASTER B RED INTACT 8 Negative 0.03
360 5/27/2025 11:56 WALL WALL PLASTER B GRAY INTACT 8 Negative 0.03
361 5/27/2025 11:56 WALL WALL PLASTER C GRAY INTACT 8 Negative 0.03
E - 16
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
362 5/27/2025 11:57 WALL WALL PLASTER C RED INTACT 8 Negative 0.03
363 5/27/2025 11:57 WALL WALL PLASTER D RED INTACT 8 Negative 0.03
364 5/27/2025 11:57 WALL WALL PLASTER D GRAY INTACT 8 Negative 0.03
365 5/27/2025 11:58 CLOSET WALL PLASTER A WHITE INTACT 8 Negative 0.04
366 5/27/2025 11:58 CLOSET CASING WOOD A VARNISH INTACT 8 Negative 0.03
367 5/27/2025 11:58 CLOSET DOOR WOOD A GRAY INTACT 8 Negative 0.04
368 5/27/2025 11:59 DOOR CASING WOOD B VARNISH INTACT 8 Negative 0.03
369 5/27/2025 11:59 DOOR CASING WOOD B VARNISH INTACT 8 Negative 0.03
370 5/27/2025 11:59 DOOR CASING WOOD B VARNISH INTACT 8 Negative 0.03
371 5/27/2025 11:59 DOOR CASING WOOD B VARNISH INTACT 8 Negative 0.03
372 5/27/2025 12:00 DOOR DOOR WOOD B VARNISH INTACT 8 Negative 0.03
373 5/27/2025 12:00 DOOR DOOR WOOD B VARNISH INTACT 8 Negative 0.04
374 5/27/2025 12:00 BASEBOARD BASEBOARD WOOD B VARNISH INTACT 8 Negative 0.76
375 5/27/2025 12:00 CEILING WALL PLASTER B WHITE INTACT 8 Negative 0.03
376 5/27/2025 12:01 WALL WALL WOOD A VARNISH INTACT 9 Negative 0.03
377 5/27/2025 12:01 WALL WALL WOOD A VARNISH INTACT 9 Negative 0.03
378 5/27/2025 12:01 WALL WALL WOOD A VARNISH INTACT 9 Negative 0.04
379 5/27/2025 12:01 WALL WALL WOOD A VARNISH INTACT 9 Negative 0.05
380 5/27/2025 12:02 DOOR CASING WOOD C VARNISH INTACT 9 Negative 0.03
381 5/27/2025 12:02 DOOR CASING WOOD C VARNISH INTACT 9 Negative 0.03
382 5/27/2025 12:02 DOOR CASING WOOD C VARNISH INTACT 9 Negative 0.03
383 5/27/2025 12:02 DOOR CASING WOOD C VARNISH INTACT 9 Negative 0.03
384 5/27/2025 12:02 DOOR DOOR WOOD C VARNISH INTACT 9 Negative 0.05
385 5/27/2025 12:02 DOOR DOOR WOOD C VARNISH INTACT 9 Negative 0.03
386 5/27/2025 12:03 CLOSET WALL PLASTER C WHITE INTACT 9 Negative 0.03
387 5/27/2025 12:03 CLOSET CASING WOOD C VARNISH INTACT 9 Negative 0.03
388 5/27/2025 12:03 CLOSET DOOR WOOD C VARNISH INTACT 9 Negative 0.04
389 5/27/2025 12:04 DOOR CASING WOOD D RED INTACT 9 Negative 0.03
390 5/27/2025 12:04 DOOR CASING WOOD D RED INTACT 9 Negative 0.03
391 5/27/2025 12:04 DOOR DOOR METAL D RED INTACT 9 Negative 0.03
392 5/27/2025 12:05 BASEBOARD BASEBOARD WOOD D VARNISH INTACT 9 Negative 0.03
393 5/27/2025 12:05 WALL UPPER TRIM WOOD D VARNISH INTACT 9 Negative 0.03
394 5/27/2025 12:05 CEILING WALL PLASTER D WHITE INTACT 9 Negative 0.04
395 5/27/2025 12:06 WALL WALL PLASTER A WHITE INTACT 10 Negative 0.03
396 5/27/2025 12:06 WALL WALL PLASTER A WHITE INTACT 10 Negative 0.03
397 5/27/2025 12:06 WALL WALL PLASTER A WHITE INTACT 10 Negative 0.03
398 5/27/2025 12:06 WALL WALL PLASTER A WHITE INTACT 10 Negative 0.03
399 5/27/2025 12:07 CLOSET WALL PLASTER A WHITE INTACT 10 Negative 0.03
400 5/27/2025 12:07 CLOSET CASING WOOD A VARNISH INTACT 10 Negative 0.03
401 5/27/2025 12:07 CLOSET DOOR WOOD A VARNISH INTACT 10 Negative 0.03
402 5/27/2025 12:07 BASEBOARD BASEBOARD WOOD A VARNISH INTACT 10 Negative 0.03
403 5/27/2025 12:08 CEILING WALL PLASTER A WHITE INTACT 10 Negative 0.03
E - 17
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
404 5/27/2025 12:09 WALL WALL TRANSITE EXT A GRAY INTACT 10 Negative 0.03
405 5/27/2025 12:10 DOOR CASING WOOD EXT A RED INTACT EXTERIOR Negative 0.75
406 5/27/2025 12:10 DOOR CASING WOOD EXT A RED INTACT EXTERIOR Negative 0.8
407 5/27/2025 12:11 DOOR DOOR METAL EXT A RED INTACT EXTERIOR Negative 0.03
408 5/27/2025 12:11 WINDOW CASING WOOD EXT A RED INTACT EXTERIOR Negative 0.1
409 5/27/2025 12:12 WINDOW SILL WOOD EXT A RED INTACT EXTERIOR Negative 0.42
410 5/27/2025 12:12 WINDOW MULLION WOOD EXT A GRAY INTACT EXTERIOR Negative 0.6
411 5/27/2025 12:13 WINDOW TRIM WOOD EXT A WHITE INTACT EXTERIOR Positive 1.9
412 5/27/2025 12:15 COLUMN WALL WOOD EXT A WHITE INTACT PORCH Negative 0.03
413 5/27/2025 12:15 COLUMN WALL WOOD EXT A RED INTACT PORCH Negative 0.03
414 5/27/2025 12:16 CEILING BEAM WOOD EXT A RED INTACT PORCH Negative 0.03
415 5/27/2025 12:16 CEILING WALL WOOD EXT A GRAY INTACT PORCH Negative 0.03
416 5/27/2025 12:17 GABLE WALL WOOD EXT A GRAY INTACT EXTERIOR Negative 0.03
417 5/27/2025 12:17 RAIL WALL WOOD EXT A WHITE INTACT PORCH Negative 0.03
418 5/27/2025 12:18 WALL WALL BLOCK EXT A RED INTACT PORCH Negative 0.03
419 5/27/2025 12:19 TRIM WALL WOOD EXT A RED INTACT EXTERIOR Negative 0.6
420 5/27/2025 12:20 ROOF SOFFIT WOOD EXT A GRAY INTACT EXTERIOR Positive 1.4
421 5/27/2025 12:20 ROOF FASCIA WOOD EXT A RED INTACT EXTERIOR Negative 0.4
422 5/27/2025 12:22 WALL WALL TRANSITE EXT B GRAY INTACT EXTERIOR Negative 0.03
423 5/27/2025 12:22 WINDOW CASING WOOD EXT B RED INTACT EXTERIOR Negative 0.6
424 5/27/2025 12:23 WINDOW SCREEN WOOD EXT B RED INTACT EXTERIOR Negative 0.26
425 5/27/2025 12:23 WINDOW SCREEN WOOD EXT A RED INTACT EXTERIOR Negative 0.45
426 5/27/2025 12:24 WINDOW SILL WOOD EXT B RED INTACT EXTERIOR Negative 0.45
427 5/27/2025 12:24 FLOOR WALL CONCRETE EXT B RED INTACT EXTERIOR Negative 0.03
428 5/27/2025 12:25 DOOR CASING WOOD EXT B RED INTACT EXTERIOR Negative 0.32
429 5/27/2025 12:25 DOOR CASING WOOD EXT B RED INTACT EXTERIOR Negative 0.45
430 5/27/2025 12:25 DOOR DOOR METAL EXT B RED INTACT EXTERIOR Negative 0.36
431 5/27/2025 12:26 WINDOW TRIM WOOD EXT B WHITE INTACT EXTERIOR Negative 0.03
432 5/27/2025 12:26 DOOR DOOR METAL EXT B RED INTACT EXTERIOR Negative 0.03
433 5/27/2025 12:27 ROOF SOFFIT WOOD EXT B GRAY INTACT EXTERIOR Positive 1.8
434 5/27/2025 12:27 ROOF FASCIA WOOD EXT B RED INTACT EXTERIOR Negative 0.06
435 5/27/2025 12:28 WALL WALL WOOD EXT B RED INTACT EXTERIOR Negative 0.04
436 5/27/2025 12:29 WINDOW MULLION WOOD EXT B GRAY INTACT EXTERIOR Negative 0.41
437 5/27/2025 12:30 WALL WALL TRANSITE EXT B GRAY INTACT EXTERIOR Negative 0.03
438 5/27/2025 12:31 TRIM WALL WOOD EXT B RED INTACT EXTERIOR Negative 0.14
439 5/27/2025 12:31 TRIM WALL WOOD EXT C RED INTACT EXTERIOR Negative 0.6
440 5/27/2025 12:31 WALL WALL TRANSITE EXT C GRAY INTACT EXTERIOR Negative 0.03
441 5/27/2025 12:32 WINDOW CASING WOOD EXT C RED INTACT EXTERIOR Negative 0.39
442 5/27/2025 12:32 WINDOW SCREEN WOOD EXT C RED INTACT EXTERIOR Negative 0.51
443 5/27/2025 12:33 WINDOW SILL WOOD EXT C RED INTACT EXTERIOR Negative 0.41
444 5/27/2025 12:33 WINDOW MULLION WOOD EXT C GRAY INTACT EXTERIOR Negative 0.63
445 5/27/2025 12:34 ROOF SOFFIT WOOD EXT C GRAY INTACT EXTERIOR Positive 1.2
E - 18
U.S. EPA Certified Lead-Based Paint Activities Firm #NAT-F178890
Reading No Time COMPONENT FEATURE SUBSTRATE SIDE COLOR CONDITION ROOM Results PbC
446 5/27/2025 12:34 ROOF FASCIA WOOD EXT C RED INTACT EXTERIOR Negative 0.03
447 5/27/2025 12:36 WALL WALL TRANSITE EXT D GRAY INTACT EXTERIOR Negative 0.03
448 5/27/2025 12:37 TRIM WALL WOOD EXT D RED INTACT EXTERIOR Negative 0.7
449 5/27/2025 12:37 DOOR CASING WOOD EXT D RED INTACT EXTERIOR Negative 0.75
450 5/27/2025 12:37 DOOR CASING WOOD EXT D RED INTACT EXTERIOR Negative 0.26
451 5/27/2025 12:38 DOOR DOOR METAL EXT D RED INTACT EXTERIOR Negative 0.55
452 5/27/2025 12:38 WALL WALL WOOD EXT D GRAY INTACT EXTERIOR Negative 0.6
453 5/27/2025 12:39 FLOOR WALL CONCRETE EXT D RED INTACT EXTERIOR Negative 0.03
454 5/27/2025 12:39 WINDOW TRIM WOOD EXT D WHITE INTACT EXTERIOR Negative 0.03
455 5/27/2025 12:40 WINDOW CASING WOOD EXT D RED INTACT EXTERIOR Negative 0.54
456 5/27/2025 12:40 WINDOW SILL WOOD EXT D RED INTACT EXTERIOR Negative 0.46
457 5/27/2025 12:40 WINDOW SCREEN WOOD EXT D RED INTACT EXTERIOR Negative 0.28
458 5/27/2025 12:41 WINDOW MULLION WOOD EXT D GRAY INTACT EXTERIOR Negative 0.3
459 5/27/2025 12:41 WALL WALL TRANSITE EXT D GRAY INTACT EXTERIOR Negative 0.03
460 5/27/2025 12:42 ROOF SOFFIT WOOD EXT D GRAY INTACT EXTERIOR Positive 1.5
461 5/27/2025 12:42 ROOF FASCIA WOOD EXT D RED INTACT EXTERIOR Negative 0.03
462 5/27/2025 12:43 CALIBRATE Positive 1
463 5/27/2025 12:43 CALIBRATE Positive 1.6
464 5/27/2025 12:43 CALIBRATE Negative 0
E - 19
APPENDIX B
LABORATORY RESULTS
E - 20
Analysis Report
Client:
Project/Test Address:
PbO3 Environmental Monitoring, LLC
LBP Risk Assessment; 812 NW 2nd St; Ocala, FL 34475
Client Number:
201413
Fax Number:
321-507-4914Laboratory Results
Analyzed Date:
Client Sample Number
Lab Sample Number
Concentration ppm (ug/g)
Lead in Soil
06/04/2025
05/30/2025
25-05-05116
Reported Date:
Received Date:
Report Number:
6548 SW 131st Place Ocala, FL 34473
Narrative ID
06/04/2025
Collection Location
05/27/2025Collection Date:
7469 Whitepine Rd
Telephone: 800.347.4010 North Chesterfield, VA 23237
55812-L-0125-05-05116-001 EXT A, B, C, D
Melissa Kanode
QA/QC Clerk
Method: ASTM E-1979-17/EPA SW846 7000B
The Reporting Limit (RL) is 10.0 ug Total Pb. All internal quality control requirements associated with this batch were met, unless otherwise noted.
LEGEND ug = microgram ppm = parts per million ug/g = micrograms per gram
Reviewed By Authorized Signatory:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Unless otherwise noted, samples are reported without a dry weight correction.
Sample location, description, area, volume, etc., was provided by the client. If the report does not contain the result for a field blank, it is due to the fact that the client did not include a field blank with their samples. EHS sample results do not reflect blank correction. This report shall not be reproduced except in full, without the written consent of Environmental Hazards Services, L.L.C.
ELLAP Accreditation through AIHA LAP, LLC (100420), NY ELAP #11714.
Page 1of1
E - 21
ACCOUNT No. 201413
Pb3 ENVIRONMENTAL MONITORING, LLC.
6548 SW 131st Place Ocala, FL 34473 (352) 203-4081 rrasmussen72@gmail.com
CHAIN OF CUSTODY DOCUMENT
25-05-05…