This request for proposal solicits offers for a High Gain Antenna System jitter damper to be used on the Wide Field Infrared Survey Telescope project. The jitter damper must meet stringent performance requirements including minimum stiffness and damping values over the specified temperature range in order to reduce jitter induced by the antenna system and maintain adequate performance. Offerors must demonstrate that their solution will provide the required isolation capability and meet all electrical, mechanical, environmental, and verification testing requirements outlined in the technical specifications. Proposals are due by the date specified, and the agency intends to make award to a single contractor.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Effective Date: February 13, 2020
National Aeronautics and Space Administration
Goddard Space Flight Center Greenbelt, Maryland
WFIRST-MECH-SPEC-0128, Revision -
Wide Field Infrared Survey Telescope (WFIRST), Code 448
High Gain Antenna System
Jitter Damper
Performance Specification
(SPEC)
GSFC WFIRST CMO
February 13, 2020
Released
WFIRST HGAS Jitter Damper Spec WFIRST-MECH-SPEC-0128, Revision -ii
High Gain Antenna System
Jitter Damper
Performance Specification
(SPEC)
Review/Signature/Approval Page
Prepared by:
Lia Sacks
Approved by:
Jason Hylan
Electronic Approval available on-line in the WFIRST CM Tool file://///gs448share/WFIRST/01.0%20Project%20Management/1.4%20Configuration-Data%20Mgmt/Templates/Document%20Templates/TDMS/Templates%20(boilerplates)/Historical/in iii
Preface
This document is a Wide Field Infrared Survey Telescope (WFIRST)
Configuration Management (CM)-controlled document. Changes to this document require prior approval of the applicable Configuration Control Board (CCB) Chairperson or designee.
Proposed changes shall be submitted to the WFIRST CM Office (CMO), along with supportive material justifying the proposed change.
In this document, a requirement is identified by “shall,” a good practice by “should,” permission by “may” or “can,” expectation by “will,” and descriptive material by “is.”
Questions or comments concerning this document should be addressed to:
WFIRST Configuration Management Office
Mail Stop 448
Goddard Space Flight Center
Greenbelt, Maryland 20771 iv
Change History Log
Revision Effective Date Description of Changes
(Reference the CCR & CCB/ERB Approval Date)
Revision - February 13, 2020 Initial Release per WFIRST-CCR-0151 v
Table of TBDs/TBRs/TBSs [optional]
Item No. Location Summary Individual/
Organization
Actionee
Due Date vi
Table of Contents
1 INTRODUCTION
1.1 Purpose
1.2 Scope
1.3 Related Documentation
1.3.1 Applicable Documents [and Forms]
1.3.2 Reference Documents
2 CONTRACT DESCRIPTION
2.1 HGAS Jitter Damper Description
2.2 Reserved
3 FUNCTIONAL/PERFORMANCE REQUIREMENTS
3.1 HGAS Jitter Damper Flight Unit Functional/Performance Requirements
3.1.1 Stiffness Requirement
3.1.2 Damping Requirement
3.2 Reserved
3.3 Reserved
3.4 Electrical Grounding
3.4.1 Reserved
3.4.2 Reserved
3.4.3 Reserved
3.4.4 Reserved
3.4.5 Reserved
3.4.6 Non-Electrical and Electro-Mechanical Bonding Resistance
3.5 Reserved
3.6 Reserved
3.7 Reserved
3.8 Reserved
4 PHYSICAL REQUIREMENTS
4.1 Interface Documentation
4.1.1 Mechanical Interface
4.1.2 Reserved
4.1.3 Reserved
4.2 Mass Properties
4.2.1 Component Masses
4.2.2 Center of Mass Location
4.2.3 Reserved
4.2.4 Reserved
4.3 Physical Envelope
4.4 Mounting
4.5 Reserved
4.6 Reserved
5 ENVIRONMENTAL REQUIREMENTS
5.1 Quasi-Static Acceleration
5.2 Frequency Requirement
vii
5.2.1 Stowed Fundamental Launch Frequencies
5.3 Vibration
5.3.1 Sinusoidal Vibration
5.3.2 Random Vibration
5.4 Shock
5.5 Reserved
5.6 Reserved
5.6.1 Operating Pressure Range
5.6.2 Maximum Depressurization Rate
5.6.3 Reserved
5.7 On-Orbit Loads
5.8 Ground Environments
5.9 Thermal Requirements
5.9.1 Flight Interface Design Temperature Limits
5.9.2 Allocation for Spacecraft Thermal Hardware
5.10 Reserved
5.11 Static Load Requirement
6 CLEANLINESS
6.1 Surface Contamination
6.1.1 Surface Contamination Levels at Delivery
6.1.1.1 Particulate Contamination
6.1.1.2 Molecular Contamination – Exposed Surfaces
6.1.1.3 Molecular Contamination – Covered Surfaces
6.1.2 Surface Contamination Generation
6.1.2.1 Particulate Generation
6.1.2.2 Molecular Generation
Material Selection Material Selection - Silicones
Assembly Outgassing
6.1.2.3 Intentional and Unintentional Vents
6.1.2.4 Intentional and Unintentional Vents – Filters
6.1.2.5 Intentional Vents – Pressure Buildup Prevention
6.1.3 Cleanability
6.1.3.1 Cleanability – Sensitive Surfaces
6.1.3.2 Cleanability – Sensitive Surface Cleaning Methods
6.1.4 Transportation Cleanliness
6.2 Charging Mitigation
6.2.1 Conductive Surface Ground Path
6.2.2 Conductive Surface Resistivity
6.2.3 Closeout of Gaps and Apertures
6.2.3.1 Conductive Tape Surface Resistivity
6.2.3.2 Conductive Tape, Grounding
6.2.4 Exposed Harness Specific Requirements
6.2.5 Reserved
7 DESIGN & CONSTRUCTION REQUIREMENTS
7.1 Parts, Materials & Processes (PMP)
viii
7.1.1 Reserved
7.1.2 Materials
7.1.2.1 Material Conductivity
7.1.3 Reserved
7.2 Reserved
7.3 Reserved
7.4 Reserved
7.5 Identification and Marking
7.6 Workmanship
7.6.1 Workmanship Standards
7.6.2 Reserved
7.7 Reliability and Mission Lifetime
7.7.1 Mission Life
7.7.2 Reserved
7.8 Reserved
8 MECHANICAL DESIGN REQUIREMENTS
8.1 Mechanical Factors of Safety
8.2 Fracture and Fatigue
8.3 Reserved
8.4 Reserved
8.5 Reserved
8.6 Materials
8.6.1 Dissimilar Metals
8.6.2 Material Allowables and Stiffness
8.6.3 CTE Data
8.6.4 Stress Corrosion Cracking
8.7 Joints
8.7.1 Joint Edge Distance
8.7.2 Bonded Joint Allowable
8.7.3 Reserved
8.7.4 Fastened Joints
8.7.4.1 Fastener Locking
8.7.4.2 Fastened Joint Margin of Safety
8.7.4.3 Installation Torque Documentation
8.7.4.4 Seal Analysis
8.7.4.5 Critical Fasteners
8.8 Mechanism Design
8.8.1 Minimum Torque
8.8.2 Torque Margin Formula
8.8.3 Mechanism Stall Performance
8.8.4 Mechanism Installation
8.8.5 Deployables and Mechanism Jamming
8.8.5.1 Non-Powered Restraint
8.8.5.2 Visual Indication of Caging
8.8.5.3 Confirmation of Deployment
8.8.5.4 Springs Failure Tolerant
ix
8.8.5.5 Tolerancing
8.8.5.6 Clearances
8.8.6 Viscous Dampers
8.8.6.1 Air Entrapment
8.8.6.2 Damper Temperature Effects
8.8.7 Motors
8.8.7.1 Brush-Type Motor Avoidance
8.8.8 Bearings
8.8.8.1 Hertzian Contact Stress
8.8.8.2 Bearing Strength and Performance
8.8.9 Switches
8.8.9.1 Indicating Device
8.8.9.2 Microswitches
8.8.10 Lubricants
8.8.10.1 Lubricant Life Analysis
8.8.10.2 Dry Lubricants
8.9 Mechanism Verification Requirements
8.9.1 Mechanism Verification
8.9.1.1 Mechanism Qualification Testing
8.9.1.2 Mechanism Life Testing
8.9.1.3 Mechanism Acceptance Testing
8.9.1.3.1.1 Functional Test Structuring
8.9.1.3.1.2 Run-In Testing
8.9.1.3.1.3 Motor Characterization Testing
9 LOGISTICS
9.1 Reserved
9.2 Reserved
9.3 Reserved
10 VERIFICATION REQUIREMENTS
10.1 Verification Methods
10.1.1 Inspection
10.1.2 Analysis
10.1.3 Test
10.2 Inspection Requirements
10.2.1 Visual Inspection
10.2.2 Physical Measurement
10.2.3 Documentation Search
10.3 Analysis Requirements
10.4 Test Requirements
10.4.1 Definitions
10.4.2 Test Factors
10.4.3 Thermal Cycle Prior to Structural Testing
10.4.4 Powered-on Conditions for Test
10.4.5 Proof Testing Factors
10.4.6 Test Tolerances
10.4.7 Test Restrictions
x
10.4.7.1 Failure During Tests
10.4.7.2 Modification of Hardware
10.4.7.3 External Adjustment
10.4.7.4 Re-Test Requirements
10.5 Required Tests
10.5.1 Performance Tests
10.5.1.1 Comprehensive Performance Test
10.5.1.2 Limited Performance Test
10.5.1.3 Reserved
10.5.1.4 Life Testing
10.5.2 Mass Properties Measurement
10.5.3 Static Loads/Strength Test
10.5.3.1 Sine Burst
10.5.3.2 Static Pull
10.5.4 Frequency Signature Survey
10.5.5 Modal Survey
10.5.6 Sine Vibration
10.5.7 Random Vibration
10.5.8 Reserved
10.5.9 Reserved
10.5.10 Shock
10.5.11 Thermal Vacuum Bake-out
10.5.12 Thermal Vacuum Test
10.5.12.1 Thermal Vacuum Test Parameters
10.5.12.2 Thermal Vacuum Test Profile
10.5.13 Thermal Balance Requirement
10.5.14 Thermal Cycling Testing - Ambient
10.5.15 Reserved
10.5.16 Reserved
APPENDIX A ABBREVIATIONS AND ACRONYMS
List of Figures
Figure 10-1 Thermal Vacuum Profile
List of Tables
Table 3-1 Stiffness Range for HGAS Jitter Damper at Root Hinge
Table 3-2 Stiffness Range for HGAS Jitter Damper at Midboom Table 5-1 HGAS Jitter Damper Design Limit Loads Table 5-2 HGAS Jitter Damper Generic Sine Vibration Environment Table 5-3 Random Vibration Limit Levels for Components Weighing Less Than 22.7 kg
Table 5-4 Minimum Workmanship ASD Level for Components Weighing Less than 45.4 kg. . 10 Table 5-5 Shock Limit Levels Table 5-6 On-Orbit Loads for HGAS Jitter Damper at Root Hinge Table 5-7 On Orbit Loads for HGAS Jitter Damper at Midboom xi
Table 5-8 Temperature Limits at Damper Mounting Interface
Table 5-9 Minimum Loads for HGAS Jitter Damper at Root Hinge Table 5-10 Minimum Loads for HGAS Jitter Damper at Midboom
Table 8-1 Design Factors of Safety Table 8-2 Minimum Edge Distance Table 8-3 Torque Margin Calculation Factors of Safety Table 8-4 Mean Hertzian Contact Stress Table 10-1 Test Factors and Durations
Table 10-2 Proof Test Factors Table 10-3 Test Tolerances Table 10-4 Thermal Vacuum Test Parameters
1 INTRODUCTION
1.1 Purpose
The Wide Field InfraRed Survey Telescope (WFIRST) is a mission responding to the 2010
National Research Council New Worlds, New Horizons (NWNH) Astronomy and Astrophysics
Decadal Survey top priority recommendation in the large space mission category. The science program includes two dedicated investigations to tackle outstanding questions in dark energy research and exoplanet exploration, and includes a substantial General Observer program to enable targeted investigations of astrophysical phenomena to advance other goals from the Decadal
Survey. A coronagraph instrument is included in the payload for purposes of advancing the present state of the art of coronagraph technology. This document defines the requirements for the HGAS jitter damper.
1.2 Scope
This specification describes the electrical, mechanical, environmental, and verification testing requirements for a space-qualified HGAS jitter damper for the NASA Goddard Space Flight
Center (GSFC) WFIRST Mission.
1.3 Related Documentation
WFIRST documents can be obtained in the WFIRST CM Tool.
1.3.1 Applicable Documents [and Forms]
The following documents and drawings in effect on the day this specification was signed shall apply to the fabrication and to the electrical, mechanical, and environmental requirements of the
HGAS jitter damper to the extent specified herein. In the event of conflict between this specification and any referenced document, this specification will govern, with the exception of the WFIRST HGAS Jitter Damper Statement of Work (WFIRST-MECH-SOW-0036), in which case the Statement of Work takes precedence.
Document Number Title
ANSI/TIA/EIA-422-B Electrical Characteristics of Balanced Voltage Digital Interface
Circuits
ANSI/TIA/EIA-644-A-2001 Electrical Characteristics of Low Voltage Differential
Signaling (LVDS) Interface Circuits
ASTM E-595-07 Standard Test Method for Total Mass Loss and Collected
Volatile Condensable Materials from Outgassing in a Vacuum
Environment
ECSS-E-ST-50-12A SpaceWire - Links, Nodes, Routers and Networks
EEE-INST-002 Instructions for EEE Parts Selection, Screening, Qualification, and Derating
IEST-STD-CC1246E Product Cleanliness Levels And Contamination Control
Program
MIL-STD-1553B Department of Defense Interface Standard for Digital Time
Division Command/Response Multiplex Data Bus
MIL-STD-461F Military Standard, Electromagnetic Emission And
Susceptibility Requirements For The Control Of
Electromagnetic Interference (EMI)
MIL-STD-462, Notice 2 Electromagnetic Interference Characteristics, Measurement of, 1 May 1970
MSFC-STD-3029A Guidelines for the Selection of Metallic Materials for Stress
Corrosion Cracking Resistance in Sodium Chloride
Environments
NFPA 70 National Fire Protection Association National Electric Code
NASA-STD-5017A Design and Development Requirements for Mechanisms
NASA-STD-5019A Fracture Control Requirements for Spaceflight Hardware
NASA-STD-5020 Requirements for Threaded Fastening Systems in Spaceflight
Hardware
NASA-STD-8719.24 NASA Expendable Launch Vehicle Payload Safety
Requirements
GSFC-STD-7000A General Environmental Verification Standard (GEVS)
541-WI-5330.1.41 Fastener Locking Using Arathane 5753
WFIRST-SYS-PLAN-0051 WFIRST Contamination Control Plan
WFIRST-MECH-LIST-0078 WFIRST HGAS Jitter Damper Deliverable Items List and
Schedule (DILS)
WFIRST-MECH-SOW-0036 WFIRST HGAS Jitter Damper Statement of Work (SOW)
WFIRST-SYS-SPEC-0031 WFIRST Math Models Guidelines Document
WFIRST-SYS-SPEC-0033 WFIRST Cleanliness Specification
MICD-2237261 Jitter Damper, HGAS Mechanical Interface Control Document
(MICD)
1.3.2 Reference Documents
The following documents are referenced herein and amplify or clarify the information presented in this document. These documents are not binding on the content of this document.
Document Number Title
N/A
2 CONTRACT DESCRIPTION
2.1 HGAS Jitter Damper Description
The HGAS jitter damper is an isolation device that is capable of reducing the transmission of excitations induced by the HGAS motion back into the spacecraft.
2.2 Reserved
3 FUNCTIONAL/PERFORMANCE REQUIREMENTS
This section defines the functional and performance requirements for the HGAS jitter damper as defined in Section 3.1.
3.1 HGAS Jitter Damper Flight Unit Functional/Performance Requirements
The HGAS jitter damper will reduce jitter induced by the High Gain Antenna System and maintain adequate stiffness and damping values over the specified temperature range. Two candidate locations are identified for the HGAS jitter damper. The first location is at the root hinge of the HGAS boom and the second location is at the middle of the HGAS boom, or midboom location.
3.1.1 Stiffness Requirement
HJD-0001 At each of the locations, the HGAS jitter damper shall comply with the minimum stiffness values provided in Table 3-1 and Table 3-2 for all operational temperatures:
Table 3-1 Stiffness Range for HGAS Jitter Damper at Root Hinge
Root Hinge Location:
Minimum
SI units Imperial
Units
Radial Stiffness [N/m (lbs/in)] 1.0E+07 5.71E+04
Axial Stiffness [N/m (lbs/in)] 2.0E+07 1.14E+05
Bending Stiffness [N-m/rad (in-lbs/rad)] 6.5E+04 5.75E+05
Torsional Stiffness [N-m/rad (in-lbs/rad)] 8.0E+04 7.08E+05
Table 3-2 Stiffness Range for HGAS Jitter Damper at Midboom
Midboom Location:
Minimum
SI units Imperial
Units
Radial Stiffness [N/m (lbs/in)] 7.0E+06 4.00E+04
Axial Stiffness [N/m (lbs/in)] 8.0E+06 4.57E+04
Bending Stiffness [N-m/rad (in-lbs/rad)] 2.3E+04 2.04E+05
Torsional Stiffness [N-m/rad (in-lbs/rad)] 4.0E+04 3.54E+05
HJD-0002 The HGAS jitter damper shall also maintain a fixed base deployed HGAS frequency of at least 2.2Hz.
HJD-0138 The HGAS jitter damper shall be evaluated to determine performance effects of waveguide and harness mounted parallel to the damper. Interaction between jitter damper, waveguide and harness will be further developed between the contractor and NASA GSFC.
Variability on any of these values can be considered on a case by case basis as long as it does not affect performance. Stiffness shall be evaluated in a fixed base configuration.
3.1.2 Damping Requirement
HJD-0003 The HGAS jitter damper shall provide at least 2% damping over the operational temperature range.
3.2 Reserved
3.3 Reserved
3.4 Electrical Grounding
3.4.1 Reserved
3.4.2 Reserved
3.4.3 Reserved
3.4.4 Reserved
3.4.5 Reserved
3.4.6 Non-Electrical and Electro-Mechanical Bonding Resistance
HJD-0004 Conductive non-electrical and electro-mechanical components shall be bonded to the observatory chassis in such a manner as to provide DC resistances not exceeding 5 ohms between the component chassis or case and the observatory chassis
3.5 Reserved
3.6 Reserved
3.7 Reserved
3.8 Reserved
4 PHYSICAL REQUIREMENTS
4.1 Interface Documentation
HJD-0005 The contractor shall use metric units when interfacing with NASA GSFC including any drawings, documents, models, except for the following cases:
SI units with parenthetical English units are permitted for engineering and manufacturing drawings.
Angular measurement may be expressed in degree of arc or in an appropriate subdivision of degree of arc such as minute or second of arc (arc-min or arc-sec).
Hardware that has been previously built, or new hardware of similar design heritage, may be specified in English units where use of metric equivalents would lead to additional risk and cost to the program, but interfaces with that hardware must use metric with parenthetical English units.
Hybrid SI/standard astronomical units are permitted for Astronomer User’s Manuals, user interfaces (Graphical User Interfaces and files) consistent with the Astronomer's User
Manuals, and requirements documents.
4.1.1 Mechanical Interface
HJD-0006 The mounting interface shall be defined in the Mechanical Interface Control Drawing
(MICD), which will be developed between the contractor and NASA GSFC.
4.1.2 Reserved
4.1.3 Reserved
4.2 Mass Properties
4.2.1 Component Masses
a. HJD-0007 The mass of the HGAS jitter damper shall be less than or equal to 3 kg.
b. HJD-0008 The mass of the HGAS jitter damper shall be measured to within 0.2%.
4.2.2 Center of Mass Location
HJD-0009 The contractor shall define the center of mass in the Mechanical ICD.
4.2.3 Reserved
4.2.4 Reserved
4.3 Physical Envelope
HJD-0010 The HGAS jitter damper outside dimensions, including mounting flanges and connectors, shall not exceed the volume specified in 2237261 (HGAS Jitter Damper MICD).
Additional restrictions to the shape of the damper are also provided in the MICD.
4.4 Mounting
HJD-0011 Mounting interface flatness, and co-planarity requirements for the component side of the interface (including brackets, if any, and shims) shall be as defined in the MICD.
4.5 Reserved
4.6 Reserved
5 ENVIRONMENTAL REQUIREMENTS
Environmental design requirements are specified in this section.
HJD-0012 The HGAS jitter damper shall meet its performance requirements in section 5.0 during and after exposure to the environments specified in this section.
5.1 Quasi-Static Acceleration
Quasi-static acceleration represents the combination of steady-state accelerations and the low frequency mechanically transmitted dynamic accelerations that occur during launch.
HJD-0013 The HGAS jitter damper shall be designed to withstand the quasi-static Design Limit
Loads (DLL) defined in the Mass-Acceleration Curve (MAC) shown in Table 5-1 without damage or degradation of performance.
Note:
1. For masses within the breakpoints, linear interpolation is used to determine load.
2. Loads are considered to act in any direction, one axis at a time.
Table 5-1 HGAS Jitter Damper Design Limit Loads
Component Mass (Kg) Limit Load (g)
0.5 35.9
1 35
5 30.1
5.2 Frequency Requirement
5.2.1 Stowed Fundamental Launch Frequencies
HJD-0014 The HGAS jitter damper shall have a fundamental frequency greater than 75 Hz when hard mounted at its interface.
1. Requirements are met assuming rigid stiffness to restrained Degree of Freedom (DOF).
2. Components with first fundamental frequency greater than 75 Hz may verify through low level signature tests. Components with a frequency less than 75 Hz are required to perform modal testing and provide a test correlated FEM for dynamic analysis. Requirements for the FEM are in the SOW and discussed in Section 10.5.5.
3. Frequency requirements apply to all modes with modal effective mass fraction (MEMF)
>5% of FEM mass. MEMF is compared to the total mass of the element/subsystem/component, not against higher levels of assembly. e.g. OBS modes
MEMF is compared to OBS mass
4. For modes with MEMF between 5% and 10% that do not meet the frequency requirement(s), additional assessments can be made by the observatory systems group to determine the effects of the mode on observatory dynamics and subsystem/element design limit loads.
5.3 Vibration
5.3.1 Sinusoidal Vibration
HJD-0015 The HGAS jitter damper shall withstand the sinusoidal vibration levels defined in
Table 5-2.
1. Levels defined are acceptance levels. Analysis is conducted against acceptance with the safety factors defined in Table 8-1. Testing factors are defined in Table 10-1.
2. Peak levels at the low end of the frequency range (5 - 20 Hz) may be ramped up as needed to accommodate table limitations.
3. The sine sweep vibration levels shown in Table 5-2 are defined at the interface of the element/subsystem.
4. Input levels may be notched to limit the test specimens CG response to 1.25 times its
Design Limit Load outlined in Table 5-1.
5. Test verification is required over the range 5 to 50 Hz. Analytical verification is required from 50 to 100 Hz.
6. Elements/Subsystems/components with a first fundamental frequency equal to or greater than 75 Hz can forgo sine vibration testing from 5 to 50 Hz, while verification through analysis of the 50 to 100 Hz is still required.
7. Subsystems/components with a fundamental frequency equal to or greater than 150 Hz can forgo the sine vibration environment until higher levels of assembly upon approval by the
NASA/GSFC COR.
Table 5-2 HGAS Jitter Damper Generic Sine Vibration Environment
Frequency (Hz) Limit Level
5 to 100 10.0 g
Levels may be notched to not exceed 1.25 times the design limit load outlined in section 5.1.
Peak levels at the low end of the frequency range (5 – 20 Hz typically) may be ramped up as needed to accommodate shaker table displacement limitations.
5.3.2 Random Vibration
a. HJD-0016 The HGAS jitter damper shall withstand the random vibration environment in
Table 5-3 applied at the interface to the HGAS jitter damper.
The random vibration inputs are based on GEVS and may be notched to limit the test article’s cg response to 1.25 times DLL. Notched inputs must envelope minimum workmanship levels in order to screen for design or manufacturing flaws. A delicate optic, detector, sensor, etc., which is shown analytically to have negative margin at minimum workmanship levels may notch further at those frequency bands with project concurrence.
Table 5-3 shows the limit level random vibration environment for components with mass less than
22.7 kg. Analysis is conducted against acceptance with the safety factors defined in Table 8-1.
Testing factors are defined in Table 10-1. Table 5-4 defines minimum workmanship for components weighing less than 45.4 kg.
During testing, force limiting control is recommended and the control method must be approved by the NASA/GSFC COR.
Table 5-3 Random Vibration Limit Levels for Components Weighing Less Than 22.7 kg
Frequency (Hz) ASD Limit Level (g2/Hz)
20 0.013
20 - 50 +6 dB/oct
50 - 800 0.08
800 - 2000 -6 dB/oct
2000 0.013
Overall 10.0 grms
Table 5-4 Minimum Workmanship ASD Level for Components Weighing Less than 45.4 kg.
Frequency (Hz) ASD Level (g2/Hz)
20 0.01
20 - 80 +3 dB/oct
80 - 500 0.04
500 - 2000 -3 dB/oct
2000 0.01
Overall 6.8 grms
5.4 Shock
HJD-0017 The HGAS jitter damper shall be designed to meet its performance requirements after being subjected to the shock environment in Table 5-5, applied at the
HGAS jitter damper interface to the WFIRST spacecraft structure. Levels defined are acceptance levels. Testing factors are defined in 10.4.2.
Table 5-5 Shock Limit Levels
Frequency (Hz) Limit Load (g)
100 100
2000 2500
10000 2500
Note: A shock susceptibility and attenuation assessment is to be performed on HGAS jitter damper. This assessment can be based on past shock tests or other relevant information.
5.5 Reserved
5.6 Reserved
5.6.1 Operating Pressure Range
HJD-0018 The HGAS jitter damper shall be designed to meet all performance requirements while operating over a pressure range of 1.08 x 105 N/m2 (813 Torr) to 1.3 x 10-12 N/m2 (1 x 10-14
Torr).
5.6.2 Maximum Depressurization Rate
HJD-0019 The HGAS jitter damper shall be designed to meet all performance requirements after exposure to a depressurization rate of 2.48 kPa/sec (0.36 psi/sec) or less with a single brief allowable peak of up to 5.03 kPa/sec (0.73 psi/sec).
5.6.3 Reserved
5.7 On-Orbit Loads
HJD-0136 The HGAS jitter damper shall meet all requirements while subjected to the following loads:
Table 5-6 On-Orbit Loads for HGAS Jitter Damper at Root Hinge
Load Condition1,2
On-Orbit Loads3
SI units Imperial
Units
Axial [N (lbs)] 22.2 5
Lateral [N (lbs)] 22.2 5
Bending [N-m (in-lbs)] 13.0 115
Torsion [N-m (in-lbs)] 0.6 5
Table 5-7 On Orbit Loads for HGAS Jitter Damper at Midboom
Load Condition1,2
On Orbit Loads3
SI units Imperial
Units
Axial [N (lbs)] 22.2 5
Lateral [N (lbs)] 22.2 5
Bending [N-m (in-lbs)] 7.3 65
Torsion [N-m (in-lbs)] 0.6 5
Notes:
1. Load conditions for each load case should be assumed to be simultaneous, and all possible sign combinations should be evaluated.
2. Lateral and bending loads should be clocked at various orientations (every 15° for example) to capture worst case loading direction.
3. Forces and Moments are to be applied to a standalone fixed-base damper analysis model.
5.8 Ground Environments
a. HJD-0020 The HGAS jitter damper shall meet all of their performance requirements during exposure to air temperature between +5 and +30 degrees C and relative humidity between 30% and 70%.
5.9 Thermal Requirements
5.9.1 Flight Interface Design Temperature Limits
a. HJD-0021 The HGAS jitter damper shall be capable of surviving indefinitely when its temperatures are within the survival limits shown in Table 5-8 without damage or permanent performance degradation.
b. HJD-0022 The HGAS jitter damper shall meet all performance requirements anywhere within the Operational and Protoflight/Qualification limits shown in Table 5-8. If all performance requirements cannot be met over the entire temperature range, the capability and stiffness/damping performance over the entire temperature range shall be provided.
Table 5-8 Temperature Limits at Damper Mounting Interface
Minimum Temperature (ºC) Maximum Temperature (ºC)
Operational (In Spec) -40 +10
Protoflight/Qualification (In
Spec)
-55 +35
Survival (Unpowered) -55 +35
5.9.2 Allocation for Spacecraft Thermal Hardware
HJD-0023 The HGAS jitter damper shall provide provisions to mount thermal hardware if thermal control is required to maintain the optimal temperature range.
5.10 Reserved
5.11 Static Load Requirement
HJD-0024 The HGAS jitter damper shall be designed such that the following static loads may be applied simultaneously, or any possible combination of loads without degradation in performance.
HJD-0025 Two candidate locations are identified for the HGAS jitter damper. At each of the locations, the HGAS jitter damper shall comply with the following minimum loads:
Table 5-9 Minimum Loads for HGAS Jitter Damper at Root Hinge
Load Condition1,2 Load Envelope3
SI units Imperial units
Axial [N (lbs)] 3,781 850
Lateral Load [N (lbs)] 2,002 450
Bending Load [N-m (in-lbs)] 1,808 16,000
Torsional Load [N-m (in-lbs)] 271 2,400
Table 5-10 Minimum Loads for HGAS Jitter Damper at Midboom
Load Condition1,2 Load Envelope3
SI units Imperial units
Axial Load [N (lbs)] 2,669 600
Radial Load [N (lbs)] 2,002 450
Bending Load [N-m (in-lbs)] 847 7,500
Torsional Load [N-m (in-lbs)] 271 2,400
Notes:
1. Load conditions for each load case should be assumed to be simultaneous, and all possible sign combinations should be evaluated.
2. Lateral and bending loads should be clocked at various orientations (every 15° for example) to capture worst case loading direction.
3. Forces and Moments are to be applied to a standalone fixed-base damper analysis model.
6 CLEANLINESS
The requirements in this section ensure the cleanliness of the HGAS jitter damper at delivery, so as not to adversely affect its own performance, as well as not be a source of contamination to other items, including not generating contaminants following delivery in excess of that permitted below by virtue of its design, materials of construction, or operation.
6.1 Surface Contamination
6.1.1 Surface Contamination Levels at Delivery
6.1.1.1 Particulate Contamination
HJD-0026 The HGAS jitter damper surfaces shall meet IEST-STD-CC1246E Particulate
Cleanliness Level 300 and shall also be visually inspected and meet Level VC-0.5-1000 + UV, or equivalent, when inspected with both UV and white light in a darkened room prior to be integrated to WFIRST.
6.1.1.2 Molecular Contamination – Exposed Surfaces
HJD-0027 The HGAS jitter damper surfaces shall meet IEST-STD-CC1246E NVR Cleanliness
Level R1 and shall also be visually inspected and meet Level VC-0.5-1000 + UV, or equivalent, when inspected with both UV and white light in a darkened room prior to be integrated to
WFIRST.
6.1.1.3 Molecular Contamination – Covered Surfaces
a. HJD-0028 All HGAS jitter damper surfaces not exposed to the space environment shall meet IEST-STD-CC1246E VC-0.5-1000 + UV, or equivalent, when inspected in a darkened room with white and UV light.
b. HJD-0029 The surfaces shall be free of molecular contamination – for example films, spots, or other.
6.1.2 Surface Contamination Generation
6.1.2.1 Particulate Generation
HJD-0030 The HGAS jitter damper contractor shall not employ any of the following particle generating materials or processes into the HGAS jitter damper design or construction without prior approval by the NASA/GSFC COR:
Paints prone to shedding due to large paint pigment molecules, overspray, poor adhesion, etc.
Surfaces prone to corrosion or oxides because of a lack of corrosion protection or dissimilar metals in close contact.
Fabrics with brittle constituents (e.g., composites, graphite or glass).
Perforated materials when material is highly susceptible to tear propagation (e.g., multi-layer insulation (MLI)).
Metal oxides (bare [untreated] aluminum and magnesium, iron, non-corrosion resistant steel, etc.).
Braided metallic or synthetic wires, ropes, slings, etc. unless measures have been taken to contain any broken filaments or fibers (sheathing, sealing with polymers, covering, etc.).
Woven materials especially cut or unfinished ends (metal braid, EMI shielding, lacing cord, expando sleeving), unless measures have been taken to prevent fraying or generation of particles (cut with a hot knife, seal with polymer, bag, etc.).
Materials with thin films known to erode or crack or flake when subjected to normal handling (e.g., indium tin oxide [ITO] or other rigid or brittle semiconductor or ceramic coating on flexible substrates, Teflon, MLI, etc.).
Foams, highly textured materials.
Trapped debris in holes.
6.1.2.2 Molecular Generation
Material Selection
HJD-0031 The HGAS jitter damper materials shall have a total mass loss (TML) less than
1.00% and a collected volatile condensable mass (CVCM) less than 0.10%, when measured in accordance with ASTM E-595 unless a materials usage agreement has been generated and approved by the NASA/GSFC COR.
Material Selection - Silicones
HJD-0032 Silicones on external (to the spacecraft) surfaces shall not be exposed to the space environment unless approved by the NASA/GSFC COR. Silicones should be avoided or minimized. It is highly recommended that silicones be baked out at a high temperature prior to integration into the system to prevent extended bakeouts of the entire assembly.
Assembly Outgassing
a. HJD-0033 The HGAS jitter damper outgassing shall be measured in a vacuum of 1E-5 torr at the unit under test’s maximum hot survival temperature based on Table 5-8. The hot operating temperature plus 5 degrees may be used with the NASA/GSFC COR’s approval.
b. HJD-0034 The HGAS jitter damper outgassing shall meet an outgassing rate of 4.41 E-
11 g/s with the QCM at -20 degrees C. It is recommended that certification be conducted after thermal cycling to take advantage of heat exposure times.
c. HJD-0035 The HGAS jitter damper outgassing measurements shall be made in a chamber that has been certified clean (back ground outgassing rate and free of silicones and other high molecular weight contaminants) and has been modeled by the
Contamination Analyst to account for mass sinks (cold fingers, pumps, cold surfaces, etc.) that could influence the source outgassing rate. A cold finger and/or a scavenger plate shall be used in the test.
d. HJD-0036 A cold finger and/or a scavenger plate shall be used in tests for components that will be mounted externally unless approved otherwise by the NASA/GSFC COR.
6.1.2.3 Intentional and Unintentional Vents
HJD-0037 When located external to the spacecraft, intentional vents (dedicated ascent vents or thermal blanket vents for example) and unintentional vents (through holes, gaps at seams and faying surfaces, thermal blanket openings and other openings) shall not impinge on the surface of instruments or other contamination sensitive surfaces (star trackers, calibration standards, contamination sensitive thermal surfaces like radiators, etc.).
6.1.2.4 Intentional and Unintentional Vents – Filters
HJD-0038 Any vents shall have filters or other means of preventing the egress of particles larger than 35 microns.
6.1.2.5 Intentional Vents – Pressure Buildup Prevention
a. HJD-0039 Intentional vents shall be sized to prevent a buildup of pressure during ascent that may result in mechanical damage.
b. HJD-0040 Intentional vents shall be sized to prevent a buildup of pressure during high vacuum due to outgassing that could result in discharges in higher voltage circuits.
6.1.3 Cleanability
6.1.3.1 Cleanability – Sensitive Surfaces
HJD-0041 If any surfaces are not cleanable with Isopropyl alcohol and polyester wipes or light vacuuming, they shall be identified on the MICD.
6.1.3.2 Cleanability – Sensitive Surface Cleaning Methods
HJD-0042 Alternate cleaning methods shall be identified and appropriate documentation provided for any surfaces that are not cleanable with Isopropyl alcohol.
6.1.4 Transportation Cleanliness
HJD-0043 Materials and enclosure used for transportation and storage shall not generate molecular or particle contaminants or degrade the surface cleanliness of the item or adjacent items
6.2 Charging Mitigation
The following paragraphs provide requirements and guidelines for minimizing the magnitude and variations in the radiated electric field from the external surfaces of the HGAS jitter damper when exposed to the space plasma. All external Observatory surfaces that are exposed to the space plasma will be sufficiently conductive and be connected to spacecraft ground through low impedance paths.
6.2.1 Conductive Surface Ground Path
HJD-0044 All HGAS jitter damper external conductive surfaces shall be connected to the spacecraft interface with a resistance less than 5 ohms, either through the use of ground wire(s) or through metal-to-metal mounting contact.
6.2.2 Conductive Surface Resistivity
HJD-0045 All HGAS jitter damper external conductive surfaces shall have a resistivity less than
10^8 ohm-cm or 10^9 ohms/square.
6.2.3 Closeout of Gaps and Apertures
HJD-0046 All gaps and apertures not required for component fields of view, deployments, or observatory venting shall be closed out with conductive tape or thermal blankets.
6.2.3.1 Conductive Tape Surface Resistivity
HJD-0047 Conductive tapes used to closeout gaps or apertures shall be designed to meet the conductive surface resistivity requirements.
6.2.3.2 Conductive Tape, Grounding
HJD-0048 The external surface of conductive tapes shall be connected to the spacecraft interface through the use of folded under tabs, or conductive adhesives.
6.2.4 Exposed Harness Specific Requirements
HJD-0049 Harnesses that are exposed to sunlight or the ambient plasma shall be bundle shielded from source to destination.
6.2.5 Reserved
7 DESIGN & CONSTRUCTION REQUIREMENTS
7.1 Parts, Materials & Processes (PMP)
7.1.1 Reserved
7.1.2 Materials
HJD-0054 The HGAS jitter damper shall be comprised of materials and processes in accordance with the requirements in the SOW, WFIRST-MECH-SOW-0036.
7.1.2.1 Material Conductivity
HJD-0055 All parts should be passivated and mounting surfaces on HGAS jitter damper shall be conductive as defined in Section 3.4.
7.1.3 Reserved
7.2 Reserved
7.3 Reserved
7.4 Reserved
7.5 Identification and Marking
HJD-0056 Each unit shall be permanently marked with the part number and a unique sequential serial number in the area designated on the interface control drawing in a manner to be approved by the NASA/GSFC COR.
HJD-0137All markings shall use alcohol proof ink, engraving, or laser etching.
7.6 Workmanship
7.6.1 Workmanship Standards
HJD-0057 The workmanship standards and processes outlined in the SOW will be used.
7.6.2 Reserved
7.7 Reliability and Mission Lifetime
7.7.1 Mission Life
HJD-0058 The HGAS jitter damper shall meet all performance specifications through three (3) years of ground testing and five (5) years of operation in space, following a three (3) month commissioning period.
7.7.2 Reserved
7.8 Reserved
8 MECHANICAL DESIGN REQUIREMENTS
For additional guidance on the design and analysis of threaded fastening systems in NASA spaceflight hardware, consult NASA-STD-5020, “Requirements for Threaded Fastening Systems
In Spaceflight Hardware”.
8.1 Mechanical Factors of Safety
HJD-0059 Positive Margin of Safety (MS) shall be demonstrated analytically for HGAS jitter damper, including interfaces to MGSE, using the MS formula below with the appropriate Factors of Safety (FS) defined in Table 8-1 applied to flight limit loads.
1. MS is defined as follows:
𝑀𝑆 =
𝐴𝑙𝑙𝑜𝑤𝑎𝑏𝑙𝑒 𝐿𝑖𝑚𝑖𝑡 𝐿𝑜𝑎𝑑 𝑜𝑟 𝑆𝑡𝑟𝑒𝑠𝑠
𝐴𝑝𝑝𝑙𝑖𝑒𝑑 𝐿𝑖𝑚𝑖𝑡 𝐿𝑜𝑎𝑑 𝑜𝑟 𝑆𝑡𝑟𝑒𝑠𝑠 ∗ 𝐹𝑆
− 1
Table 8-1 Design Factors of Safety
Type of Hardware Static /Sine Random/Acoustic 3,4
Tested Metallic Yield 1.252 1.6
Tested Metallic Ultimate 1.42 1.8
Stability/Buckling Ultimate 1.4 1.8
Beryllium Yield 1.4 1.8
Beryllium Ultimate 1.6 2.0
Composite Ultimate1 1.5 1.9
Bonded inserts/Joints Ultimate 1.5 1.9
Glass/Ceramic 3.05 3.8
Bond in Glass/Ceramic 1.5 1.9
(1) All composite structures must be tested to 1.25 x limit loads.
(2) For qualification by analysis only, positive margin must be shown with FS of 2.0 and 2.6 for metallic yield and ultimate, respectively.
(3) Factors shown are applied to statistically derived peak response based on limit/acceptance RMS level.
As a minimum, the peak response must be calculated as a 3-sigma value.
(4) Factors shown assume that qualification testing is performed at 3dB above limit/acceptance limits. If the difference between acceptance and qualification is less than 3dB then the above factors may be applied to qualification minus 3dB.
(5) For qualification by analysis only, a no-test safety factor of 5.0 may be used for glass (not ceramic), per
NASA-STD-5001B Table 3.
8.2 Fracture and Fatigue
HJD-0060 The vendor shall evaluate all hardware to determine fracture criticality. A four-tier system is used to evaluate fracture criticality of hardware; each tier has associated mitigation requirements that shall be followed, as specified below.
Tier 1 fracture classification: Light-weighted optics, ceramic structural elements used to transfer load from one component to another, and any glass/ceramic hardware designated high risk by WFIRST shall mitigate risk of catastrophic failure due to cracks/flaws through the following requirements:
a. Proving design is fail-safe
Or,
a. Industry standard fracture analysis using NASGRO, Flaw Growth Analysis per NASA-
STD-5018, or other fracture analysis software demonstrating safe-life for 4 times number of mission cycles.
And,
b. Positive MS using B-basis Weibull accounting for Weibull scale effect per ASTM C1683
And,
c. Slow crack growth analysis of glass/ceramics made of materials with SiO bonds
Or,
a. Positive MS using B-basis Weibull accounting for Weibull scale effect per ASTM C1683
And,
b. Proof testing with 2.0 proof test factor
For all flight hardware designated Tier 1 fracture critical, a Fracture Control Plan (FCP) shall be developed and approved by the WFIRST FCB.
Tier 2 fracture classification. All glass/ceramics not classified as Tier 1 shall mitigate risk of catastrophic failure due to cracks/flaws through the following requirements:
a. Proving design is fail-safe
Or,
a. Positive MS using B-basis Weibull accounting for Weibull scale effect (ASTM 1683)
Or
a. Industry standard fracture analysis using NASGRO, Flaw Growth Analysis per NASA-
STD-5018, or other fracture analysis software demonstrating safe-life for 4 times number of mission cycles
Tier 3 fracture classification: Metals with fracture toughness to yield strength ratio less than
0.33 (KIc/Fty < 1.66 mm1/2 (0.33 in1/2)); thin walled metallic components serving as springs or flexures; and fastened joints identified as critical, that experience unconcentrated stress at greater than 30% of Ultimate strength shall mitigate risk of catastrophic failure due to cracks/flaws through the following requirements:
a. Proving design is fail-safe
Or,
a. Demonstrate sufficient fatigue strength for 4 times the number of mission cycles
Or,
a. Prove safe-life design through industry standard linear-elastic fracture analysis for 4 times the number of mission cycles.
Tier 4 fracture classification: Fracture control requirements (per NASA-STD-5019) shall apply to the following elements only: (1) Pressure vessels, dewars, lines, and fittings (per NASA-STD
8719.24);(2) Castings (unless hot isostatically pressed and the flight article is proof tested to 1.25 times limit load);(3) Weldments;(4) Parts made of materials in Tables II or III of MSFC-SPEC-
3029A if under sustained tensile stress;(5) Parts made of materials susceptible to cracking during quenching;(6) Nonredundant, mission-critical preloaded springs loaded to greater than 25 percent of ultimate strength.
Notes for fracture/fatigue:
1. Fracture analysis is performed assuming an initial crack size. NDE or proof testing is required to verify this initial crack size assumption. If proof testing, the proof tests must be at load sufficient enough to screen for any crack size above the assumed. This often results in over-test compared to DLL.
2. If NASGRO is used for brittle component fracture analysis, the NASGL module is used.
3. If the max principle stress in the glass/ceramic containing SiO bonds in the glass with a minimum detectable crack size (a) is calculated (from KIc =σ√πa) to be within 25% of fracture toughness, then slow crack growth is not a concern.
4. A fail-safe component is a structural component in a redundant load path which after the loss of the component, the remaining load path(s) has sufficient structural capability to withstand the redistributed loads, and the loss of the component will not cause a catastrophic hazard.
Examples of redundant load paths are multiple fasteners in bolted joints, stitched welded structures, and riveted and bolted structures. A factor of safety of 1.0 shall be applied to the remaining load path(s) when demonstrating fail-safe.
5. Critical fastened joints are joints whose failure results mission ending failure. Class-C fasteners that are contained within Class-C hardware are not critical fasteners.
6. Mission cycles include ground testing and handling, transportation, launch, and on orbit loading. The load spectrum will include the load level and the accompanying number of cycles and duration (for static loading) at each level during the hardware service life. Mission cycle load spectrum is included in the FCP.
7. In cases where fracture toughness of a metal is not known, contact WFIRST project for help in fracture classification.
8.3 Reserved
8.4 Reserved
8.5 Reserved
8.6 Materials
8.6.1 Dissimilar Metals
HJD-0061 Dissimilar materials in direct contact with each other shall be compatible as defined in
Table I of MIL-STD-889C, unless approved by the Parts, Materials and Processes Control Board.
1. Use of similar materials sealed per NASA-STD-6012 may be acceptable in some instances.
8.6.2 Material Allowables and Stiffness
HJD-0062 Material allowables and stiffness shall be:
a) At least A-basis for metallic materials as defined in MMPDS or B-basis values tested under the appropriate environments.
b) At least B-basis for composite materials as defined in CMH-17, or B-basis values tested under the appropriate environments and representative of the processes used in the fabrication of the components while accounting for strength degradation due to thermal cycles.
c) B-basis values for glass/ceramics based on Weibull distribution, or using a test verified threshold stress, or a value of 6.9 MPa (1 ksi. Used in the absence of test data).
1. A and B basis statistics apply to material allowables only.
8.6.3 CTE Data
HJD-0063 Coefficient of Thermal Expansion (CTE) data for materials shall be tested or obtained for the range of maximum survival temperature down to minimum survival temperature.
1. Obtained data requires project approval for use.
8.6.4 Stress Corrosion Cracking
HJD-0064 All metallic materials shall be selected from Table I of MSFC-STD-3029, unless otherwise approved by Parts, Materials, and Processes Control Board.
8.7 Joints
8.7.1 Joint Edge Distance
HJD-0065 The minimum bolt edge distance shall be as specified in Table 8-2 unless a detailed analysis is performed to justify otherwise.
Notes
1. Use appropriate bearing value from MMPDS for metals
2. D = Bolt hole or insert sleeve diameter, e = edge distance from center of bolt to edge of panel
Table 8-2 Minimum Edge Distance
Minimum Edge Distance (e/D)
Composite/Ceramic 2.5 min
Metallic 1.5 min
8.7.2 Bonded Joint Allowable
HJD-0066 Bonded joint allowables shall be B-basis produced through coupons representative of flight hardware, tested under their appropriate environments, and taking into account strength degradation due to thermal cycles.
Rationale: Bond strength is dependent on materials and workmanship, e.g. surface prep. Due to scatter from the workmanship process and material variability, B basis allowables are developed for structural analysis.
Note: Bonded joints on flight hardware are proof tested to 1.25 times limit load.
8.7.3 Reserved
8.7.4 Fastened Joints
8.7.4.1 Fastener Locking
HJD-0067 Each threaded fastening system in spaceflight hardware shall incorporate a minimum of one locking feature that does not depend upon preload to function.
1. Locking features and their installation processes, including verification methods, should be specified in the engineering documentation.
2. Locking features should be verifiable per Section 7.6 of NASA-STD-5020.
8.7.4.2 Fastened Joint Margin of Safety
HJD-0068 Positive MS for all threaded fastening systems shall be demonstrated for:
a) Ultimate design loads under all structural failure modes in conjunction with the applicable maximum expected range of environmental conditions without failure per the following:
1) The ultimate design load, Pu, is calculated using the following formula.
2) 𝑃𝑈 = 𝐹𝐹 ∗ 𝐹𝑆𝑈 ∗ 𝑃𝐿
i. where FF is the fitting factor, FSu is the ultimate factor of safety, and PL is the limit load.
3) The fitting factor (FF) defined in NASA-STD-5020 Appendix A.12 is used.
4) Analysis for ultimate design loads will address potential rupture in all elements of the threaded fastening system, including the fastener, the internally threaded part, such as a nut or an insert, and the clamped parts.
5) Insert pull-out strengths given in vendor documentation typically assume full bolt to insert thread engagement. An appropriate knock down in pull-out strength is included if the bolt does not fully engage the insert.
6) Ultimate strength analysis of a fastening system under applied tensile loading is performed per NASA-STD-5020, Section 6.2.1.
7) Ultimate strength analysis of a fastening system under applied shear loading is performed per NASA-STD-5020, Section 6.2.2.
8) Ultimate strength analysis of bolts under shear loading is based on the assumption that no shear load is carried by friction between the faying surfaces.
9) For fasteners under simultaneous applied tensile and shear loads, along with any applicable bending analysis will account for interaction of the combined loading per NASA-STD-5020, Section 6.2.3.
10) When possible, joints should be designed for bearing failure rather than bolt tension or shear failure.
b) Yield design loads in conjunction with the applicable maximum expected range of environmental conditions without detrimental yielding per the following:
1. If one or more of the following applies:
i. Fastener yielding causes the joint to separate under an applied tensile load that is less than the design separation load;
ii. Fastener yielding causes the joint to suffer detrimental slip under an applied shear load that is less than the applicable design shear load;
iii. Some other design-specific reason exists for why fastener yielding is detrimental (e.g., any fastener yielding that adversely affects the form, fit, or function of the design);
then fastener yielding is detrimental and analysis is performed per NASA-STD-5020, Section 6.3 to show the fastener’s total tensile load, when accounting for maximum preload and the yield design tensile load, does not exceed the allowable yield tensile load.
2. The yield design load, PY, is calculated using the following formula.
𝑃𝑌 = 𝐹𝐹 ∗ 𝐹𝑆𝑌 ∗ 𝑃𝐿
where FF is the fitting factor, FSY is the yield factor of safety, and PL is the limit load.
3. The fitting factor (FF) defined in NASA-STD-5020 Appendix A.12 will be used.
4. If MS for joint slip is shown to be positive, friction may be included as a shear load path for yield strength analysis of joint members (e.g. bearing). NASA-STD-5020 section 6.4 is used for joint slip analysis.
c) Gapping load in conjunction with applicable maximum or minimum temperatures without gapping per the following:
1) Margin of safety for gapping is defined as follows:
i) 𝑀𝑆𝑠𝑒𝑝 = 𝑃𝑝−𝑚𝑖𝑛
𝐹𝐹∗𝐹𝑆𝑠𝑒𝑝∗𝑃𝐿
- 1 where FF is the fitting factor, and Pp-min is the minimum preload.
2) Gapping factor of safety (FSsep) of 1.0 for non-gapping critical joints, FSsep=1.25 for non-catastrophic failure gapping critical joints, and FSsep=1.4 for catastrophic failure gapping critical joints is used for margin calc.
3) The fitting factor (FF) defined in NASA-STD-5020 Appendix A.12 will be used.
4) NASA-STD-5020, Section 6.5 is used to guide gapping analysis to show no separation for each threaded fastening system that is subject to applied tensile loading, with the assumption of minimum preload.
5) Analysis of threaded fastening systems will address nominal, maximum, and minimum preloads per NASA-STD-5020 Section 6.1.
See NASA-STD-5020, section 6.2 as reference.
8.7.4.3 Installation Torque Documentation
HJD-0069 Engineering documentation shall specify the installation torque range or specify an applicable standard that defines the installation torque range.
1. The engineering documentation should clearly identify when the installation torque is the torque above running torque.
8.7.4.4 Seal Analysis
HJD-0070 For a joint that maintains a seal (e.g., to maintain pressure or contain a fluid), the seal shall meet its requirements at the design separation load when assuming minimum preload for all fasteners in the joint.
8.7.4.5 Critical Fasteners
HJD-0071 Fastened joints identified as critical shall be demonstrated as either safe-life or fail-safe.
1. Critical joints will be identified with project concurrence. Critical joint’s failure lead to mission ending failure.
2. A safe-life component is a structural component which can be demonstrated to have at least
4 design life cycles under all…