This is a Laboratory Report for Bulk Sample Asbestos Evaluation using Polarized Light Microscopy Method, conducted by TEM Environmental, Inc. for Fermi Lab at the Kirk & Wilson Roads location in Batavia, IL. The report details asbestos testing results for six samples collected from Ramsey Door 10&11 and Paint 22 Sauk, analyzed on 4/12/2025 by Lori Boersma. Of the six samples examined (including black textured door paint, wood pattern VFT, and associated mastic), one sample (Lab ID 567497, a black associated mastic) tested positive for asbestos, specifically containing 2-3% Chrysotile asbestos fibers and 5-7% Cellulose non-asbestos fibers. The other samples were reported as "None Detected" for asbestos. The report includes a Chain of Custody form and notes that additional testing using transmission electron microscopy is recommended for conclusive results, particularly for samples with potentially small, undetectable fibers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sauk 22 project_RFI List_ 20JUNE2025.pdf | ||
| 22 Sauk - New Fire Alarm.pdf | ||
| Amendment No. 2.pdf | ||
| 22 Sauk Remodel SOW_Revised.pdf | ||
| 22 Sauk - Existing Fire Alarm.pdf | ||
| Amendment No. 1.pdf | ||
| RFP368982 Package.zip | ZIP file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BULK SAMPLE ASBESTOS EVALUATION BY
POLARIZED LIGHT MICROSCOPY METHOD
Client: Fermi Lab
Contact Mitch Lindgren
TEM Project: 76290
Project Reference: Ramsey Door 10&11; Paint 22 Sauk
Analyzed by: Lori Boersma
Date Analyzed: 4/12/2025
Lab ID Color Filler
Binder
Comments
Fibrous Materials
Asbestos Fibers
Type Percent
Non-Asbestos Fibers
Type Percent
Client Sample ID
Sample Information
Address: Kirk & Wison Rds.
Batavia IL 60510-
Non-Fibrous Materials
Description
Project Location:
LABORATORY REPORT
Asbestos Present
567495 Black None Detected 90-100250410ML004
Black Textured Door Paint
567496 Brown None Detected 90-100250410ML008
Wood Pattern VFT
SLM- - --
567497 Black Yes 90-93250410ML008(M)
Associated Mastic
2-3Chrysotile: 5-7Cellulose:
567498 Brown None Detected 90-100250410ML009
Wood Pattern VFT
SLM- - --
567499 Black250410ML009(M)
Associated Mastic Not Analyzed- - --
567500 Brown None Detected 90-100250410ML010
Wood Pattern VFT
SLM- - --
567501 Black250410ML010(M)
Associated Mastic Not Analyzed- - --
Page 1 of 2TEM Project: 76290 NVLAP Lab Code: 101130-0
630-790-0880 INFO@TEM-INC.COM 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139
BULK SAMPLE ASBESTOS EVALUATION BY
POLARIZED LIGHT MICROSCOPY METHOD
Client: Fermi Lab
Contact Mitch Lindgren
TEM Project: 76290
Project Reference: Ramsey Door 10&11; Paint 22 Sauk
Analyzed by: Lori Boersma
Date Analyzed: 4/12/2025
Lab ID Color Filler
Binder
Comments
Fibrous Materials
Asbestos Fibers
Type Percent
Non-Asbestos Fibers
Type Percent
Client Sample ID
Sample Information
Address: Kirk & Wison Rds.
Batavia IL 60510-
Non-Fibrous Materials
Description
Project Location:
LABORATORY REPORT
Asbestos Present
Report Approved by:
Samples are analyzed following the procedures contained in the USEPA Method 600/R-93/116 July 1993. This report applies only to samples analyzed. This report may not be reproduced except in full and with the approval of TEM Environmental, Inc. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US government. An estimate of the laboratory uncertainty is available upon request.
SLM: Certain samples may warrant additional analysis beyond the standard USEPA Polarized Light Microscopy method. 1) Further testing using the point count method is recommend for friable samples found to contain less than 10% asbestos by PLM to confirm that the samples are in fact regulated asbestos containing materials (RACM) as defined by the USEPA NESHAP Regulation.
2) The optical resolution of a polarized light microscope limits the size of fibers that are visible. In cases where very small fibers may be present, such as in samples of floor tiles, vermiculite or certain construction adhesives, the result of the PLM analysis is not conclusive when the sample is reported as "None Detected" or “Trace”. Further testing using transmission electron microscopy is recommended in those cases where samples may contain very small fibers which may be smaller than the resolution limit of a polarized light microscope. All such services are available for an additional fee.