RFP_30501-01726_Amendment_1.pdf
PDF 3 MB Posted
- Attached to
- Security Guard Services - UPDATED State and local contract opportunity
- Solicitation number
- RFP 30501-01726
- Issued by
- Davidson County, Tennessee
About this file
This document is a Request for Proposals (RFP) # 30501-01726, Amendment # 1, issued by the Tennessee Secretary of State for Security Guard Services. The RFP amendment updates the schedule of events, with key dates including a mandatory onsite pre-response conference and facility tour on August 18, 2025, a response deadline of September 12, 2025, and state notice of intent to award on October 1, 2025. The procurement timeline includes various milestones such as a deadline for written questions, state responses to questions, technical response evaluations, cost proposal scoring, and negotiations, with the contract expected to be sent to the contractor for signature by October 10, 2025.
The amendment includes architectural floor plans and overall building plans for a new Library and Archives building located at 1001 5th Avenue N. in Nashville, Davidson County, Tennessee. The detailed blueprints cover multiple levels including garage, level 1, level 2, level 3, level 4, and roof plans, providing comprehensive architectural details for the facility. The plans were developed by Tuck-Hinton Architects and Thomas, Miller and Partners, with the original documents dated June 1, 2018, and subsequently updated through various construction document phases in 2018 and 2019.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| RFP_30501-01726_Protest_Procedures.pdf | ||
| RFP_30501-01726_Security_Guard_Services_TSLA.pdf | ||
| RFP_30501-01726_Notice_of_Intent_to_Award.pdf | ||
| RFP%2030501-01726_Security%20Guard%20Services%3b%20TSLA%20-%20Amendment%202.pdf | ||
| RFP_30501-01726_Amendment_1.pdf | ||
| RFP%2030501-01726_Security%20Guard%20Services%3b%20TSLA%20-%20Amendment%202.pdf | ||
| RFP_30501-01726_Security_Guard_Services_TSLA.pdf | ||
| RFP_30501-01726_Amendment_1.pdf | ||
| RFP_30501-01726_Security_Guard_Services_TSLA.pdf | ||
| RFP_30501-01726_Security_Guard_Services_TSLA.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP # 30501-01726 – Amendment # 1 Page 1 of 6
STATE OF TENNESSEE
SECRETARY OF STATE
REQUEST FOR PROPOSALS # 30501-01726
AMENDMENT # 1
FOR SECURITY GUARD SERVICES
DATE: August 19, 2025
RFP # 30501-01726 IS AMENDED AS FOLLOWS:
1. This RFP Schedule of Events updates and confirms scheduled RFP dates. Any event, time, or date containing revised or new text is highlighted.
EVENT
TIME
(central time zone)
DATE
1. RFP Issued AUGUST 11, 2025
2. Disability Accommodation Request Deadline 2:00 p.m. AUGUST 14, 2025
3. Mandatory Onsite Pre-Response Conference and Facility Tour
9:00 a.m. AUGUST 18, 2025
4. Notice of Intent to Respond Deadline 2:00 p.m. AUGUST 19, 2025
5. Written “Questions & Comments” Deadline 2:00 p.m. AUGUST 22, 2025
6. State Response to Written “Questions & Comments”
SEPTEMBER 5, 2025
7. Response Deadline 2:00 p.m. SEPTEMBER 12, 2025
8. State Completion of Technical Response Evaluations
SEPTEMBER 19, 2025
9. State Opening & Scoring of Cost Proposals 9:00 a.m. SEPTEMBER 23, 2025
10. Negotiations SEPTEMBER 24-26, 2025
11. State Notice of Intent to Award Released and RFP Files Opened for Public Inspection
2:00 p.m. OCTOBER 1, 2025
12. End of Protest Period OCTOBER 8, 2025
13. State sends contract to Contractor for signature
OCTOBER 10, 2025
14. Contractor Signature Deadline 2:00 p.m. OCTOBER 14, 2025
2. Add the following as RFP Attachment Two and renumber any subsequent sections as necessary:
P H
O
TO
C O
P Y
DN
DN
UP
DN
P H
O
TO
C O
P Y
DN
DN
DN
UP
UP
UP
UP
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
PC.3 L1
0.8 0.5
0.1
A.S.R.S.
SUPPORT &
SERVER
ROOM
01.0189
FIRE RISER &
VALVES
01.0192
P.C.
SET-UP/INFO
STORAGE
01.0191
BLDG
MAINTENANCE
STORAGE
01.0182
SECURITY
01.0203
RECEIVING/
HOLDING
01.0200
ISOLATION
WORKROOM
01.0201
L.B.P.H.
WORKROOM/
HOLDING
01.0205
MACHINE
REPAIR
01.0214
MAN.
OFFICE
01.0215
L.B.P.H.
OPEN
OFFICE
01.0217
ELEC.
01.0177
STAIR #3
01.0003
ACCESSIBLE
EARLY
LITERACY
ENGAGEMENT
CENTER
01.0106
LOBBY
01.0100
ELEVATOR
LOBBY
01.0115
ELEC.
01.0158
PUBLIC
L.B.P.H.
READING
RM
01.0111
L.B.P.H. DIR.
01.0153
L.B.P.H.
ADMINISTRATION
01.0147
WOMEN
01.0112
MEN
01.0113
SECURITY
01.0132
VENDING
01.0116
LARGE
COLLECTION
ROOM
01.0176
IT ROOM
01.0146
STAFF
LUNCH RM
01.0140
CLASSROOM
#1
01.0138
CLASSROOM
#2
01.0134
PREP ROOM
01.0131MTG.
REGISTRATION
01.0126
BREAKOUT
ROOM
01.0127
A/V
CONTROLS
01.0129
CORR.
01.0120
STORAGE
01.0121 A/V
STORAGE
01.0119
STORAGE
01.0135
OUTREACH
LIBRARIAN
01.0155
STAFF/
VISITOR
ELEV #2
01.0020
ASRS
OFFICE
01.0171
GEN.
STOCK RM
01.0166
FACILITIES
ADMIN.
01.0172
DIRECTOR
01.0174
MAIL/COPY
RM
01.0165
SURPLUS
PROPERTY
STORAGE
01.0178
BOILER
ROOM
01.0221
LOBBY
EQUIPMENT
01.0168
RARE
BOOKS
01.0109
CUSTODIAN
WORKROOM
01.0186
CUSTODIAL/
RECYCLING
01.0133
FAMILY
01.0114
RECYCLING/
RECEIVING
& STAGING
01.0199
CHILLER
ROOM
01.0194
IT ENTRY
ROOM
01.0188
ENCLAVE
01.0216
ELECTRICAL
SWITCHGEAR
01.0193
WEST
TENNESSEE
01.0122
EAST
TENNESSEE
01.0124
MIDDLE
TENNESSEE
01.0123
CORR.
01.0130
VEST.
01.0102
VEST.
01.0101
STAFF
ENTRY#3
01.0198
ELEV CNTRL
01.0157
CORR.
01.0170
G.8A
AUDIO
HERITAGE
LAB
01.0160
STUDIO A /
CONTROL
ROOM
01.0161
STUDIO B /
RECORDING
ROOM
01.0162
MEN
(LKRS/SHWR)
01.0183
WOMEN
(LKRS/SHWRS)
01.0184
LOADING
DOCK
01.0220
CUSTODIAN
STORAGE
01.0187
SECURITY
SERVER
ROOM
01.0196
LOADING
DOCK #1
01.0197
L.B.P.H.
WORKROOM
01.0143
STORAGE
01.0142
STORAGE
01.0118
.6
CORR.
01.0145
CORR.
01.0117
STAFF
ENTRY#2
01.0150
CORR.
01.0180
LOBBY
EQUIP.
01.0164
RECYCLING
01.0175
STORAGE
01.0139
CORR.
01.0125
BLAST
FREEZER
01.0202
STAFF/
VISITOR
ELEV #1
01.0010
STORAGE
01.0108
DISPLAY
SUPPORT
AREA
01.0169
CORR.
01.0190
BLDG
MAINTENANCE
SHOP
01.0181
CHILLER
ROOM
VIEW
01.0195
9'-7" 10'-0" 10'-0" 5'-9" 14'-3" 20'-0" 20'-0" 20'-0" 17'-4" 2'-8" 20'-0" 20'-0" 20'-0" 14'-0" 6'-0" 10'-0" 10'-0"
232'-8"
20'-10"
E Q
E Q
STAIR #1
01.0001
STAIR #4
01.0004
STAIR #2
01.0002
PARKING
ACCESS
STAIR #5
01.0005
STAFF ELEV
#3
01.0030
PARKING
ACCESS
ELEV #4
01.0040
FREIGHT
ELEV #5
01.0050
CHASE
01.0070
ELEVATOR
LOBBY
01.0163
MONUMENTAL
STAIR
01.0103
IT ROOM
01.0128
CORR.
01.0104
CORR.
01.0105
LOBBY
DISPLAY
LOBBY
DISPLAY
CORR.
01.0185
CORR.
01.0190
A / V 01.0167
ORIENTATION
ALCOVE
01.0141
/3 A101C /3 A101C
/1 A101A
/1 A101B
/1 A101B /1 A101B
/1 A101A
/1 A101B
1 1
5.1
224'-0"
1 1
20.66
GRAPHIC SYMBOLS
THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY
FIELD CONDITIONS AND SHALL CAREFULLY COMPARE SUCH FIELD
MEASUREMENTS, CONDITIONS, AND OTHER INFORMATION
KNOWN TO THE CONTRACTOR WITH THE CONTRACT DOCUMENTS
BEFORE COMMENCING ACTIVITIES. ERRORS, INCONSISTENCIES
OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE
ARCHITECT AT ONCE.
THE CONTRACTOR SHALL NOT SCALE DRAWINGS.
DIMENSIONS ARE INDICATED AS FOLLOWS UNLESS OTHERWISE
NOTED:
1. COLUMNS - FROM CENTERLINE TO CENTERLINE
2. METAL STUD PARTITIONS - FROM CENTERLINE TO CENTERLINE
3. CONCRETE - FROM FACE OF CONCRETE TO FACE OF
CONCRETE
4. MASONRY - FROM FACE OF MASONRY TO FACE OF MASONRY
5. EXTERIOR WALL - FROM EXTERIOR FACE OF WALL TO INTERIOR
CENTERLINE OF STUD
6. INTERIOR ELEVATION - FROM FINISHED FLOOR TO FINISHED
CEILING
7. DOOR SHALL BE LOCATED 6" FROM CLEAR OPENING TO
ADJACENT WALL UNLESS OTHERWISE NOTED.
8. ALL FLOOR TO FLOOR AND CEILING HEIGHTS SHOWN ON
DRAWINGS ARE FROM FINISH FLOOR.
BWINDOW TAG
WALL TYPE REFERENCE:
REFER TO SHEET G003 FOR
ADDITIONAL INFORMATION
DOOR MARK
DOOR
SYMBOL
ROOM NUMBER
A
X.0
WALL LEGEND
NOTES
NEW CONSTRUCTION
NON-RATED PARTITION1B1A1
1E1D1C
NON-RATED SOUND PARTITION2P2C2B2A
AUDIO HERITAGE LAB PARTITION,
REFER TO PLAN FOR RATING
2Z2Y2X2W
NON-RATED SMOKE
TIGHT PARTITION
3B3A
4B4A
SMOKE BARRIER (1 HOUR FIRE
RESISTANCE RATING REQUIRED)
5B5A 1 HOUR FIRE BARRIER
2 HOUR SHAFT ENCLOSURE
2 HOUR FIRE BARRIER
1 HOUR SHAFT ENCLOSURE9S
10S
7B7A
13G13F13E
13D13C13B13A CMU PARTITION - REFER TO
PLAN FOR RATING
CONCRETE WALL - REFER TO
PLAN FOR RATING
14D14C14B14A
1H1G1F
ACCESS CONTROL LEGEND
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
PC.3 L1
G.8
A
MACHINE
ROOM
GA.0101
STAIR #3
GA.0003
2%
2%
0"
0"
[No Slope]
0"
[No Slope]
0"
[No Slope]
0"
9'-7" 10'-0" 10'-0" 5'-9" 14'-3" 20'-0" 20'-0" 20'-0" 17'-4" 2'-8" 20'-0" 20'-0" 20'-0" 14'-0" 6'-0" 10'-0" 10'-0"
(20) PARKING
SPACES
(1) HC PARKING
SPACE
(149) PARKING
SPACES TOTAL
(4) PARKING
SPACES
(23) PARKING
SPACES
(22) PARKING
SPACES
(22) PARKING
SPACES
(22) PARKING
SPACES
(17) PARKING
SPACES
(2) PARKING
SPACES
NO SLOPE
@ -3'-0"
BELOW
GARAGE
LEVEL
20.8
P U
B
LI
C Z
O N
E
S
TA
F F Z
O N
E
STAIR #2
GA.0002
VEST
GA.0103
PARKING
ACCESS
HYDRAULIC
ELEV #4
GA.0040
ELEV
MACHINE
GA.0100
BUILDING
SERVICES
GA.0102
FREIGHT
HYDRAULIC
ELEV #5
GA.0050
(6) PARKING
SPACES
STAIR #1
GA.0001
STAIR #4
GA.0004
PARKING
ACCESS
STAIR #5
GA.0005
PASSENGER
ELEV #1
AND #2
GA.0105
STAFF ELEV
#3
GA.0106
CHASE
GA.0107
OPEN AIR
STORAGE
GA.0109
(3) PARKING
SPACES
DRIVE
DRIVE
DRIVE
DRIVE
DRIVE
DRIVE
OPEN AIR
STORAGE
GA.0108
(1) PARKING
SPACE
SANITARY
SUMP PIT
(1)HC PARKING
SPACE
(1) HC PARKING
SPACE
(1) HC PARKING
SPACE
(1) PARKING
SPACE
(1) PARKING
SPACE
(1) VAN
ACCESSIBLE HC
PARKING SPACE
AREA WAY
A R
E A W
A Y
A R
E A W
A Y
AREA WAY
A R
E A W
A Y
A R
E A W
A Y
STORM
PIT
AUTO GATE
AUTO GATE
PROX CR,
OR,
Ai
/1 A100A
/1 A100B
/1 A100A
/1 A100B
FD
FD
FD
231'-11 1/2"
231'-11 1/2"
5.1
20.6620.67
(1) HC PARKING
SPACE
C R
LEVEL 1 OVERALL PLAN
020' 20'10'020' 20'10'
GARAGE LEVEL OVERALL
PLAN
TU
C
K -H
IN
TO
N A
R C
H
IT
E C
TS
TH
O
M A
S M
IL
LE
R A
N D
P A
R
TN
E R
S
A
JO
IN
T
V E N
TU
R
E
S B
C
/0
-0
-2
/2
/2
:2
:2
A M
B
IM
/A
T e n n e ss e e
S ta te L ib ra ry A n d
A rc h iv e s/
A
R
C e n tr a l.r v t
N E W
L
IB
R A
R Y
A
R C
H
IV
E S B
U
IL
D
IN
G
TH
A
V E N
U E N
N
A S H
V
IL
LE
D
A V
ID
S O
N C
O U
N
TY
TN
TMP No. A03305 THA No. 17016
1 JUNE 2018
A010
OVERALL FLOOR PLAN -
GARAGE & LEVEL 1
95% CONSTRUCTION DOCUMENTS
1 100% CONSTRUCTION
DOCUMENTS
10/31/2018
2 ASI-05 - RESPONSE TO
100% CD TFM REVIEW OF
PLANS #2
12/10/2018
3 ASI-10 - METRO
NASHVILLE PLANS
REVIEW COMMENT
RESPONSES
02/11/2019
4 ASI-15 - METRO CODE
FINAL RESPONSE
03/26/2019
Attachment 2
UP
DN
DN
P H
O
TO
C O
P Y
PHOTOCOPY
P H
O
TO
C O
P Y
DN
P H
O
TO
C O
P Y
DN
UPUP
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
P
C.3 L1
0.80.5
0.1
G.8A
MECH.
CHASE #2
MECH.
CHASE #4
MECH.
CHASE #3
MEN
03.0173
STAFF
CORR.
03.0180
ARCHIVAL
TECH.
SERVICES
COLLECTIONS
STORAGE
03.0206
PRESERVATION
SERVICES
DIRECTOR'S
OFFICE
03.0162
ENCLAVE
03.0166
PRINTER
STATION/
SUPPLY
STORAGE
03.0164
A/V
WORKROOM
& LAB
03.0104
IN-PROCESS/
HOLDING
AREA
03.0103
LIBRARY
SERVICES
WORKROOM/
COPY
ROOM
03.0208
LIBRARY
TECH.
SERVICES
COLLECTIONS
STORAGE
03.0207
PRESERVATION
SERVICES
OPEN
OFFICE
03.0145
ARCHIVAL
TECH. DIR.
03.0189
LIBRARY
SERVICES
DIRECTOR
03.0194
SECURE
CLIMATE
CONTROLLED
STORAGE
(MICROFILM)
03.0169
ELEC.
03.0178
ELEC.
03.0211
ENCLAVE
03.0192
ENCLAVE
03.0191
CUSTODIAL
03.0212
ARCHIVES &
MANUSCRIPTS
PROCESSING
WORKROOM
03.0102
ARCHIVAL
TECHNICAL
SERVICES
03.0107
LIB.
SERVICES
WORKROOM
03.0209
RECYCLING
03.0221
IT ROOM
03.0175
R E C
Y C
LI
N
G
.0
ARCHIVES
TECH.
COPY/STOR.
03.0101
WOMEN
03.0174
A.S.R.S.
WORKROOM
03.0232
CORR.
03.0170
ELEV.
LOBBY
03.0100
A.S.R.S.
CHAMBER
03.0230
DIGITAL
LIBRARIAN
03.0163
CUSTODIAL
03.0182
ENCLAVE
03.0126
STORAGE
03.0177
WELLNESS
ROOM
03.0176
CONTROLLER
ROOM
03.0179
DIGITAL
(PHOTOGRAPHIC)
WORKROOM
03.0141
MICROFILM
DARKROOM
03.0140
CHEM. RM
03.0139
CONSERVATION
LAB
03.0131
CONSERVATION
STORAGE
03.0132
CAM. RM
03.0137
NEWSPAPER
AND
MICROFILM
WORKROOM
03.0133
CORR.
03.0165
CAM. RM
03.0138
CAM. RM
03.0136
QUALITY
CONTROL -
FILM HOLD
03.0134
STORAGE
03.0167
CORR.
03.0130
STAFF
CORR.
03.0220
STAFF
CORR.
03.0210
STORAGE
03.0172
STAIR #1
03.0001
STAIR #4
03.0004
STAIR #2
03.0002
STAIR #3
03.0003
STAFF/
VISITOR
ELEV #1
03.0010
STAFF/
VISITOR
ELEV #2
03.0020
STAFF ELEV
#3
03.0030
FREIGHT
ELEV #5
03.0050
BOOK LIFT
ELEV #6
03.0060
CHASE
03.0070
IT
03.0144
SECURITY
03.0143
PRINTER
STATION
03.0190
ADMIN.
ASSISTANT
WORKSTATION
03.0188
ADMIN.
ASSISTANT
WORKSTATION
03.0193
LIBRARY
TECH.
SERVICES
OPEN
OFFICE
03.0195
A.S.R.S.
MECH.
03.0231
COFFEE
03.0168
COFFEE
03.0128
SECURE
CLIMAGE
CONTROLLED
STORAGE
(HISTORIC)
03.0171
/1 A103A /1 A103A
/1 A103B /1 A103B
1"
9'-7" 10'-0" 10'-0" 5'-9" 14'-3" 20'-0" 20'-0" 20'-0" 17'-4"
2'-8"
20'-0" 20'-0" 20'-0" 14'-0"
6'-0"
10'-0" 10'-0"
223'-4"
5.1
.6
20.6620.67
GRAPHIC SYMBOLS
THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY
FIELD CONDITIONS AND SHALL CAREFULLY COMPARE SUCH FIELD
MEASUREMENTS, CONDITIONS, AND OTHER INFORMATION
KNOWN TO THE CONTRACTOR WITH THE CONTRACT DOCUMENTS
BEFORE COMMENCING ACTIVITIES. ERRORS, INCONSISTENCIES
OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE
ARCHITECT AT ONCE.
THE CONTRACTOR SHALL NOT SCALE DRAWINGS.
DIMENSIONS ARE INDICATED AS FOLLOWS UNLESS OTHERWISE
NOTED:
1. COLUMNS - FROM CENTERLINE TO CENTERLINE
2. METAL STUD PARTITIONS - FROM CENTERLINE TO CENTERLINE
3. CONCRETE - FROM FACE OF CONCRETE TO FACE OF
CONCRETE
4. MASONRY - FROM FACE OF MASONRY TO FACE OF MASONRY
5. EXTERIOR WALL - FROM EXTERIOR FACE OF WALL TO INTERIOR
CENTERLINE OF STUD
6. INTERIOR ELEVATION - FROM FINISHED FLOOR TO FINISHED
CEILING
7. DOOR SHALL BE LOCATED 6" FROM CLEAR OPENING TO
ADJACENT WALL UNLESS OTHERWISE NOTED.
8. ALL FLOOR TO FLOOR AND CEILING HEIGHTS SHOWN ON
DRAWINGS ARE FROM FINISH FLOOR.
BWINDOW TAG
WALL TYPE REFERENCE:
REFER TO SHEET G003 FOR
ADDITIONAL INFORMATION
DOOR MARK
DOOR
SYMBOL
ROOM NUMBER
A
X.0
WALL LEGEND
NOTES
NEW CONSTRUCTION
NON-RATED PARTITION1B1A1
1E1D1C
NON-RATED SOUND PARTITION2P2C2B2A
AUDIO HERITAGE LAB PARTITION,
REFER TO PLAN FOR RATING
2Z2Y2X2W
NON-RATED SMOKE
TIGHT PARTITION
3B3A
4B4A
SMOKE BARRIER (1 HOUR FIRE
RESISTANCE RATING REQUIRED)
5B5A 1 HOUR FIRE BARRIER
2 HOUR SHAFT ENCLOSURE
2 HOUR FIRE BARRIER
1 HOUR SHAFT ENCLOSURE9S
10S
7B7A
13G13F13E
13D13C13B13A CMU PARTITION - REFER TO
PLAN FOR RATING
CONCRETE WALL - REFER TO
PLAN FOR RATING
14D14C14B14A
1H1G1F
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
P
C.3 L1
0.80.5
0.1
TENNESSEE
READING
ROOM
02.0105
LOBBY
02.0100
INTERNAL
CONFERENCE
RM
02.0170
DIR. P&D
02.0121
DIR. REG.
LIB.
02.0123
ARCHIVES
DEVELOPMENT
OPEN
OFFICE
02.0130
LOCKERS
02.0101
MECH.
CHASE #3
ELEC.
02.0214
MICROFILM
READING
ROOM
02.0106
LE
G
IS
LA
TI
V
E H
IS
TO
R Y
LI
S
TE
N
IN
G /V
IE
W
IN
G
.0
MICROFILM
02.0111
PUBLIC
SERV. OPEN
OFFICE &
WORKSTATIONS
02.0175
MANUSCRIPTS
STOR.
02.0108
PUB. SERV.
OFFICE
02.0198
PUB. SERV.
OFFICE
02.0199
PUB. SERV.
DIRECTOR
02.0196
PUB. SERV.
OFFICE
02.0197
ARCHIVES
DEVELOPMENT
STORAGE
02.0122
CHAIR
STORAGE
02.0169
PUB. SERV.
STORAGE
02.0204
BOOK LIFT
ELEV #6
02.0060
WOMEN
02.0112
MEN
02.0113
IT ROOM
02.0213
LEGISLATIVE
STORAGE
02.0172
A.S.R.S.
MECH.
02.0231
A.S.R.S.
LOBBY
02.0225
CUSTODIAL/
RECYCLING
02.0203
WOMEN
02.0212
MEN
02.0211
SECURITY
02.0202
RESEARCH
WRK RM
02.0223
RESEARCH
WRK RM
02.0224
RESEARCH
WRK RM
02.0226
RESEARCH
WRK RM
02.0227
A.S.R.S.
CHAMBER
02.0230
COPY
ROOM
02.0102
CORR.
02.0220
CORR.
02.0120
COAT/COFFEE
02.0201
STATE LIB.
02.0129
G.8A
ASST.
ARCH.
02.0124
ASST. LIB.
02.0127
ADMIN
ASSISTANT
02.0126
DEVELOPMENT
WORKROOM
02.0166
ENCLAVE
02.0143
ENCLAVE
02.0144
WOMEN
02.0141
MEN
02.0142
COPY
02.0128
CORR.
02.0200
COPY/STORAGE
02.0168
ELEC.
02.0222
RECYCLING
02.0221
MECH.
CHASE #2
MECH.
CHASE #4
STACKS
02.0104
STAIR #1
02.0001
STAIR #4
02.0004
STAIR #2
02.0002
STAIR #3
02.0003
STAFF/
VISITOR
ELEV #1
02.0010
STAFF/
VISITOR
ELEV #2
02.0020
STAFF ELEV
#3
02.0030
FREIGHT
ELEV #5
02.0050
CHASE
02.0070
MONUMENTAL
STAIR
02.0103
BUILDING
STORAGE
02.0109
SECURITY
02.0164
IT ROOM
02.0165
CORR.
02.0125
K
IT
C H
E N
E
TT
E
.0
CORR.
02.0140
CORR.
02.0210
VESTIBULE
02.0171
PLANNING
DEVELOPMENT
OPEN
OFFICE
02.0145
/1 A102A /1 A102A
/1 A102B /1 A102B
1"
9'-7" 10'-0" 10'-0" 5'-9" 14'-3" 20'-0" 20'-0" 20'-0" 17'-4"
2'-8"
20'-0" 20'-0" 20'-0" 14'-0"
6'-0"
10'-0" 10'-0"
5.1
20.6620.67
TU
C
K -H
IN
TO
N A
R C
H
IT
E C
TS
TH
O
M A
S M
IL
LE
R A
N D
P A
R
TN
E R
S
A
JO
IN
T
V E N
TU
R
E
S B
C
/0
-0
-2
/3
/2
:3
:1
P
M
B
IM
/A
T e n n e ss e e
S ta te L ib ra ry A n d
A rc h iv e s/
A
R
C e n tr a l.r v t
N E W
L
IB
R A
R Y
A
R C
H
IV
E S B
U
IL
D
IN
G
TH
A
V E N
U E N
N
A S H
V
IL
LE
D
A V
ID
S O
N C
O U
N
TY
TN
TMP No. A03305 THA No. 17016
1 JUNE 2018
A011
OVERALL FLOOR PLAN - LEVEL 2
& LEVEL 3
95% CONSTRUCTION DOCUMENTS
LEVEL 3 OVERALL PLAN DIMENSION & NOTE
REFERENCE
020' 20'10'
LEVEL 2 OVERALL PLAN
020' 20'10'
1 100% CONSTRUCTION
DOCUMENTS
10/31/2018
DN
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
PL1
0.8
0.5
G.8
MECH.
PENTHOUSE
04.0100
A
9'-7" 10'-0" 10'-0" 20'-0" 20'-0" 20'-0" 20'-0" 17'-4" 2'-8" 20'-0" 20'-0" 20'-0" 14'-0" 6'-0" 10'-0" 10'-0" 10'-0"
1"
CONTROLLER
ROOM
04.0101
MECH.
CHASE #2
MECH.
CHASE #3
MECH.
CHASE #4
STAIR #2
04.0002
STAIR #3
04.0003
STAFF ELEV
#3
04.0030
FREIGHT
ELEV #5
04.0050
J.5
/1 A104A /1 A104A
/1 A104B/1 A104B
5.1
149'-7 1/8" 54'-1 3/4" 19'-3 1/8"
SLOPE
SLO
PE
SLOPE
SL
O
PE
SLOPE
SLO
PE
SLOPE
SLO
PE
SL
O
PE
SLO
PE
FD
FD
FD
20.66 20.67
GRAPHIC SYMBOLS
THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY
FIELD CONDITIONS AND SHALL CAREFULLY COMPARE SUCH FIELD
MEASUREMENTS, CONDITIONS, AND OTHER INFORMATION
KNOWN TO THE CONTRACTOR WITH THE CONTRACT DOCUMENTS
BEFORE COMMENCING ACTIVITIES. ERRORS, INCONSISTENCIES
OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE
ARCHITECT AT ONCE.
THE CONTRACTOR SHALL NOT SCALE DRAWINGS.
DIMENSIONS ARE INDICATED AS FOLLOWS UNLESS OTHERWISE
NOTED:
1. COLUMNS - FROM CENTERLINE TO CENTERLINE
2. METAL STUD PARTITIONS - FROM CENTERLINE TO CENTERLINE
3. CONCRETE - FROM FACE OF CONCRETE TO FACE OF
CONCRETE
4. MASONRY - FROM FACE OF MASONRY TO FACE OF MASONRY
5. EXTERIOR WALL - FROM EXTERIOR FACE OF WALL TO INTERIOR
CENTERLINE OF STUD
6. INTERIOR ELEVATION - FROM FINISHED FLOOR TO FINISHED
CEILING
7. DOOR SHALL BE LOCATED 6" FROM CLEAR OPENING TO
ADJACENT WALL UNLESS OTHERWISE NOTED.
8. ALL FLOOR TO FLOOR AND CEILING HEIGHTS SHOWN ON
DRAWINGS ARE FROM FINISH FLOOR.
BWINDOW TAG
WALL TYPE REFERENCE:
REFER TO SHEET G003 FOR
ADDITIONAL INFORMATION
DOOR MARK
DOOR
SYMBOL
ROOM NUMBER
A
X.0
WALL LEGEND
NOTES
NEW CONSTRUCTION
NON-RATED PARTITION1B1A1
1E1D1C
NON-RATED SOUND PARTITION2P2C2B2A
AUDIO HERITAGE LAB PARTITION,
REFER TO PLAN FOR RATING
2Z2Y2X2W
NON-RATED SMOKE
TIGHT PARTITION
3B3A
4B4A
SMOKE BARRIER (1 HOUR FIRE
RESISTANCE RATING REQUIRED)
5B5A 1 HOUR FIRE BARRIER
2 HOUR SHAFT ENCLOSURE
2 HOUR FIRE BARRIER
1 HOUR SHAFT ENCLOSURE9S
10S
7B7A
13G13F13E
13D13C13B13A CMU PARTITION - REFER TO
PLAN FOR RATING
CONCRETE WALL - REFER TO
PLAN FOR RATING
14D14C14B14A
1H1G1F
22.9
25.1
NMLKJHGFEDCB M.5
B.5
20.9
P
L1
0.80.5
0.1
G.8A
9'-7" 10'-0" 10'-0" 20'-0" 20'-0" 20'-0" 20'-0" 17'-4" 2'-8" 20'-0" 20'-0" 20'-0" 14'-0" 6'-0" 10'-0" 10'-0"
10'-0"
1"
/1 A105A /1 A105A
/1 A105B/1 A105B
223'-9 1/2"
5.1
20.6620.67
TU
C
K -H
IN
TO
N A
R C
H
IT
E C
TS
TH
O
M A
S M
IL
LE
R A
N D
P A
R
TN
E R
S
A
JO
IN
T
V E N
TU
R
E
S B
C
/0
-0
-2
/3
/2
:3
:4
P
M
B
IM
/A
T e n n e ss e e
S ta te L ib ra ry A n d
A rc h iv e s/
A
R
C e n tr a l.r v t
N E W
L
IB
R A
R Y
A
R C
H
IV
E S B
U
IL
D
IN
G
TH
A
V E N
U E N
N
A S H
V
IL
LE
D
A V
ID
S O
N C
O U
N
TY
TN
TMP No. A03305 THA No. 17016
1 JUNE 2018
A012
OVERALL FLOOR PLAN - LEVEL 4
95% CONSTRUCTION DOCUMENTS
020' 20'10'
LEVEL 4 OVERALL PLAN DIMENSION & NOTE
REFERENCE
020' 20'10'
OVERALL ROOF PLAN
1 100% CONSTRUCTION
DOCUMENTS
10/31/2018
GARAGE
RFP # 30501-01726 – Amendment # 1 Page 1 of 6
3. RFP Amendment Effective Date. The revisions set forth herein shall be effective upon release. All other terms and conditions of this RFP not expressly amended herein shall remain in full force and effect.
File details come from the government source that posted it. Updated .