RFP-25-13_Master_Contract_Pricing_and_Inventory_List_2025-Final_Revised_Protected-Addendum_1.xlsx
XLSX spreadsheet 78 KB Posted
- Solicitation number
- RFP-25-13
- Issued by
- Florida
About this file
This is a master contract pricing and inventory list for the Canaveral Port Authority (CPA), detailing comprehensive life safety systems inspection, maintenance, and monitoring services across approximately 20 different locations. The contract covers a base period of three years starting October 1, 2025, with potential two one-year extensions, targeting fire sprinkler systems, fire alarm systems, and intrusion detection systems. The solicitation requires a contractor licensed as a Fire Protection Systems Contractor II and an Alarm System Contractor I, capable of performing quarterly and annual inspections of fire sprinkler systems, electric fire pumps, FM-200 dry chemical systems, and providing 24/7 fire/security alarm system monitoring via wireless equipment.
The pricing sheet breaks down inspection frequencies and quantities for multiple CPA facilities, including cruise terminals, parking garages, fire stations, and administrative buildings. While specific total contract value is not disclosed, the document indicates detailed equipment inventories across various locations, including fire panels, pull stations, smoke detectors, horn/strobes, and other safety devices. The proposal evaluation will be subjective, allocating 100 points across methodology (25 points), experience and qualifications (45 points), and pricing (30 points). Sealed proposals are due September 3, 2025, at 2:00 PM EDT, with the selection committee meeting on September 9, 2025, to review proposals and produce a final ranking for CPA Board of Commissioners approval on September 24, 2025.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Master Pricing Sheet
| Canaveral Port Authority Contract Pricing Sheet - ADDENDUM 1 | Fire Alarm | FM200 Systems | Sprinkler Systems | Fire Pumps | Kitchen Hoods | Monitoring | ||||||||||||||||||||||||
| Site Name | Address | Quantity | Fire Alarm Inspection Frequency | Cost Each | Quantity | Fire Alarm Inspection Frequency | Cost Each | Quantity | FM200 Inspection Frequency | Cost Each | Quantity | Sprinkler Inspection Frequency | Cost Each | Quantity | Sprinkler Inspection Frequency | Cost Each | Quantity | Sprinkler Inspection Frequency | Cost Each | Quantity | Fire Pump Inspection Frequency | Cost | Quantity | Fire Pump Inspection Month | Fire Pump Monthly Flow Test | Cost Each | Quantity | Kitchen Hood Inspection Frequency | Cost Each | Annual Monitoring Cost |
| Canaveral Port Authority - 405 Warehouse | 405 Atlantis Rd Cape Canaveral Fl32920 | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 10 | 9005 Charles Roland Dr Cape Canaveral | 1 | Annual | 1 | Semi-Annual | 2 | Semi-Annual | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 10 Parking Garage | 9022 Charles Roland Dr Cape Canaveral | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Cruise Terminal #5 | 9245 Charles M Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority-Cruise Terminal #5 Parking Garage | 9250 Charles N Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #8 | 9155 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 2 | Semi-Annual | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 1 | Annual | 11 | Monthly | 0 | N/A | |||||||||||
| Canaveral Port Authority -Cruise Terminal #8 Parking Garage | 9154 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 6 | 9241 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 6 Parking Garage | 9240 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Fire Station # 52 | 8970 Columbia Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 2 | Semi-Annual | N/A | ||||||||||
| Canaveral Port Authority -IMOC Fire Station #54 | 680 Magellan Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 2 | Semi-Annual | N/A | ||||||||||
| Canaveral Port Authority -Maritime Center | 445 Challenger Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -North Warehouse | 400 Dolphin Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Exploration Tower | 670 Dave Nisbet Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 1 | Annual | 11 | Monthly | 0 | N/A | |||||||||||
| Canaveral Port Authority -720 Mullet | 720 Mullet Road | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal 1 | 9050 Discovery Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority-Cruise Terminal 1 Parking Garage | 9060 Discovery Rd | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - 9001 Marlin | 9001 Marlin St | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority-Fire Ship & Tower | 8970 Columbia Rd | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 1 | Annual | 0 | N/A | 0 | N/A | N/A | ||||||||||
| Canaveral Port Authority - Maritime Purchasing Center | 399 Challenger Rd | 0 | N/A | 0 | N/A | 2 | Semi-Annual | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Exploration Tower - Panic Alarm | 670 Dave Nisbet Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Maritime Center - Panic Alarm | 445 Challenger Rd | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Jetty Park Guard Booth - Panic Alarm | 240 Jetty Park Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Jetty Park Campstore - Panic Alarm | 9035 Campground Cir | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal 1 - Intrusion Detection | 9050 Discovery Rd | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority -Cruise Terminal #5 - Intrusion Detection | 9245 Charles M Roland Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 6 - Intrusion Detection | 9241 Charles Roland Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal # 8 - Intrusion Detection | 9155 Charles Roland Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #10 - Intrusion Detection | 9005 Charles Roland Dr Cape Canaveral | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #3 | 220 Christopher Columbus Dr | 1 | Annual | 1 | Semi-Annual | 2 | Semi-Annual | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | Annual | 0 | Monthly | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #3 - Parking Garage | 220 Christopher Columbus Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #3 - Intrusion Detection | 220 Christopher Columbus Dr | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #10 East Parking Garage | 9004 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A | |||||||||||
| Canaveral Port Authority - Cruise Terminal #6 West Parking Garage | 9230 Charles Roland Dr | 1 | Annual | 1 | Semi-Annual | 0 | N/A | 1 | Annual | 1 | Semi-Annual | 2 | Quarterly | 0 | N/A | 0 | N/A | 0 | N/A |
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
There are no tabs for panic alarms and intrusion detection
TOTAL ANNUAL COST OF INSPECTION AND MONITORING CONTRACT $0.00
| Hourly Rate for Repair Work | $0.00 |
| Trip Charge for Repair Work | $0.00 |
| % Material Mark Up for Repair Work | 0.00% |
Signature:
Title:
Date:
405 Atlantis
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 19 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 48 |
| Duct Detectors - Functional test | 11 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 70 |
| Speakers | 0 |
| Heat Detectors | 4 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 8 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 2 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 1
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 40 |
| Smoke Detector - Sensitivity report from panel per 250 | |
| SmokeDetectors - Test & Inspect | 10 |
| Duct Detectors - Functional test | 28 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 206 |
| Speakers | 0 |
| Heat Detectors | |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 6 |
| Tamper Switches | 10 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 1 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 4 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 3
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 30 |
| Smoke Detector - Sensitivity report from panel per 250 | |
| SmokeDetectors - Test & Inspect | 36 |
| Duct Detectors - Functional test | 35 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 234 |
| Speakers | 0 |
| Heat Detectors | |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 10 |
| Tamper Switches | 21 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 1 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 7 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 1 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 3
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | |
| SmokeDetectors - Test & Inspect | 3 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | |
| Speakers | 0 |
| Heat Detectors | 8 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 1 |
| Tamper Switches | 9 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 1 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 2 |
| Standpipe | 1 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 1
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | |
| SmokeDetectors - Test & Inspect | 3 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | |
| Speakers | 0 |
| Heat Detectors | 8 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 1 |
| Tamper Switches | 9 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 1 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 10
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| 4100 | |
| Fire Panel(s) | 1 |
| Pull Stations | 21 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 33 |
| Duct Detectors - Functional test | 18 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 84 |
| Speakers | 53 |
| Heat Detectors | |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 3 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 3 |
| Tamper Switches | 3 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 1 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Special Hazards (Test & Inspect | Quantity: |
| FM200 or Halon System - Up to 300# Tank | 1 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 3 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 10 West
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | 1 |
| SmokeDetectors - Test & Inspect | 1 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 4 |
| Speakers | 0 |
| Heat Detectors | 3 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 2 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 2 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 2 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 10 East
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 10 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 4 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 0 |
| Speakers | 0 |
| Heat Detectors | 4 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 4 |
| Tamper Switches | 6 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 1 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 0 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 2 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 5
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 28 |
| Smoke Detector - Sensitivity report from panel per 250 | 1 |
| SmokeDetectors - Test & Inspect | 9 |
| Duct Detectors - Functional test | 16 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 57 |
| Speakers | 0 |
| Heat Detectors | 6 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 5 |
| Annunciator | 1 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 3 |
| Tamper Switches | 3 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 1 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 3 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 5
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | 1 |
| SmokeDetectors - Test & Inspect | 1 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 4 |
| Speakers | 0 |
| Heat Detectors | 3 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 2 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 2 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 2 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 8
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Notifer NFS2-640 | |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 15 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 149 |
| Speakers | 0 |
| Heat Detectors | 5 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 4 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 2 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Special Hazards (Test & Inspect | Quantity: |
| FM200 or Halon System - Up to 300# Tank | 1 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 3 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 1 |
| Private Fire Hydrants | 0 |
Parking Garage 8
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 13 |
| Smoke Detector - Sensitivity report from panel per 250 | |
| SmokeDetectors - Test & Inspect | 14 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 24 |
| Speakers | 0 |
| Heat Detectors | 1 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 6 |
| Tamper Switches | 9 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 6 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Cruise Terminal 6
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 10 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 107 |
| Speakers | 0 |
| Heat Detectors | 6 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 4 |
| Tamper Switches | 6 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 1 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 1 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 4 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 6 East
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 10 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 0 |
| Speakers | 0 |
| Heat Detectors | 4 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 4 |
| Tamper Switches | 6 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 4 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 0 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 2 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Parking Garage 6 West
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 10 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 0 |
| Speakers | 0 |
| Heat Detectors | 4 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 4 |
| Tamper Switches | 6 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 0 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 2 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Fire Ship & Tower
COVERED EQUIPMENT:
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | |
| Anti-Freeze Loops | 0 |
| Fire Pump | 1 |
| Private Fire Hydrants | 0 |
Fire Station 52
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Simplex | |
| Fire Panel(s) | 1 |
| Pull Stations | 8 |
| Smoke Detector - Sensitivity report from panel per 250 | 3 |
| SmokeDetectors - Test & Inspect | 0 |
| Duct Detectors - Functional test | 6 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 0 |
| Speakers | 0 |
| Heat Detectors | 5 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 1 |
| Tamper Switches | 1 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 0 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 1 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
| Kitchen Hoods (Test & Inspect) | Quantity: |
| Hood System (incl 1 tank, 3 links) | 1 |
| Additional Tanks | |
| Additional Links | 0 |
Fire Station 54
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight 5808 | |
| Fire Panel(s) | 1 |
| Pull Stations | 5 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 2 |
| Duct Detectors - Functional test | 1 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 19 |
| Speakers | 0 |
| Heat Detectors | 0 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 1 |
| Tamper Switches | 3 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 0 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 1 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
| Kitchen Hoods (Test & Inspect) | Quantity: |
| Hood System (incl 1 tank, 3 links) | 1 |
| Additional Tanks | |
| Additional Links | 0 |
Maritime Center
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 19 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 14 |
| Duct Detectors - Functional test | 12 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 84 |
| Speakers | 0 |
| Heat Detectors | 6 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 1 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 3 |
| Tamper Switches | 5 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 2 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 3 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
400 Dolphin
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 2 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 0 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 21 |
| Speakers | 0 |
| Heat Detectors | 1 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 2 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 2 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Exploration Tower
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 0 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 23 |
| Duct Detectors - Functional test | 19 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 70 |
| Speakers | 0 |
| Heat Detectors | 3 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 7 |
| Tamper Switches | 21 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 1 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 6 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 1 |
| Private Fire Hydrants | 0 |
720 Mullet
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | 1 |
| SmokeDetectors - Test & Inspect | 1 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 1 |
| Speakers | 0 |
| Heat Detectors | 0 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 1 |
| Tamper Switches | 2 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 1 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
9001 Marlin
COVERED EQUIPMENT:
| Fire Alarm (Test & Inspect) | Quantity: |
| Make/Model: | |
| Silent Knight | |
| Fire Panel(s) | 1 |
| Pull Stations | 1 |
| Smoke Detector - Sensitivity report from panel per 250 | 0 |
| SmokeDetectors - Test & Inspect | 1 |
| Duct Detectors - Functional test | 0 |
| Elevator Recall | 0 |
| PIV's (Post indicator valve) | 0 |
| AV's, Horn/Strobes | 2 |
| Speakers | 0 |
| Heat Detectors | 1 |
| Warden Phone Jacks | 0 |
| Transponder | 0 |
| NAC | 0 |
| Annunciator | 0 |
| Other (AHU input, relays, etc.) | 0 |
| Vesda Early Detection Device | 0 |
| WaterFlow | 2 |
| Tamper Switches | 2 |
| Dact (Dialer Panel) | 0 |
| Door Holder | 0 |
| Smoke/Fire Damper | 0 |
| Fire Door Inspections | 0 |
| Rolling Fire Doors | 0 |
| Actuators | 0 |
| Monitoring | Quantity: |
| Single building fire alarm service | 1 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 0 |
| Sprinkler System (Test & Inspect) | Quantity: |
| Wet/Dry Sprinkler Risers | 2 |
| Dry Sprinkler Trip Test | 0 |
| Additional Control Assemblies | 0 |
| Deluge Risers | 0 |
| AFFF (Foam tank inspect & lab analysis of foam) | 0 |
| Fire Hose Stations | 0 |
| Standpipe | 0 |
| Anti-Freeze Loops | 0 |
| Fire Pump | 0 |
| Private Fire Hydrants | 0 |
Jetty Park Booth
| Monitoring | Quantity: |
| Single building fire alarm service | 0 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 1 |
Jetty Park Store
| Monitoring | Quantity: |
| Single building fire alarm service | 0 |
| Single building burglar alarm service | 0 |
| Multi building applications (same dialer) (each building) | 0 |
| Single building combo panel service (fire/security) | 0 |
| Elevator Service (Phone) | 0 |
| Parking Lot Service (Phone) | 0 |
| Duress / Panic | 1 |
Maritime Purchasing Center
| Special Hazards (Test & Inspect | Quantity: |
| FM200 or Halon System - Up to 300# Tank | 1 |
File details come from the government source that posted it. Updated .