RFP_1100_MMH3041_ATT_v1.pdf
PDF 129 KB Posted
- Attached to
- Utility Pump Maintenance and Replacement
- Solicitation number
- RFP 1100 MMH3041
- Issued by
- Texas
About this file
This is a scope of work attachment for a pump repair and modification project issued by Austin Energy for the Sand Hill Energy Center in Texas. Austin Energy requires a qualified pump repair service vendor to disassemble, inspect, repair, and modify an ITT Gould's 42XX52GHX0-1 Circulating Water Pump (Unit 5, Pump #3) that was shut down due to high vibrations during operation. The pump, Serial No. 312910-1, has been in continuous service since October 2005 and was previously repaired in 2005 when the original impeller was replaced with a stainless steel impeller due to damage. The pump specifications are Model VIT-FF, operating at 590 RPM with a capacity of 59,000 GPM and a head of 83 feet. The selected contractor must develop a comprehensive repair work scope based on best practice and industry standards for this pump type and service application, and shall recommend and implement modifications to improve the pump's reliability.
The contractor shall complete a detailed inspection and repair assessment, developing the work scope according to established industry standards and best practices for circulating water pumps of this classification. The scope of work attachment does not specify pricing terms, contract duration, award dates, or bid submission deadlines within the provided document. This project is part of Austin Energy's broader utility pump maintenance and replacement initiative across multiple facilities including the Sand Hill Energy Center, Decker Creek Power Station, and on-site energy resources in Texas.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB_9100_AAM1023_PAC1_v1.pdf | ||
| RFP_1100_MMH3041_PLANS_v1.pdf | ||
| RFP_1100_MMH3041_0500_v1.pdf | ||
| RFP_1100_MMH3041_PAC1_v1.pdf | ||
| RFP_1100_MMH3041_ROCIP_v1.pdf | ||
| RFP_1100_MMH3041_BID_DOC_v1.docx | DOCX document | |
| RFP_1100_MMH3041_ATT_3_v1.pdf | ||
| RFP_1100_MMH3041_MWDBE_PAC_v1.pdf | ||
| RFP_1100_MMH3041_PAC2_v1.pdf | ||
| RFP_1100_MMH3041_0600_v1.pdf | ||
| RFP_1100_MMH3041_ATT_2_v1.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT E
AUSTIN ENERGY
SAND HILL ENERGY CENTER
Sample Work scope
FOR
REPAIR AND MODIFY
UNIT 5 CIRCULATING WATER PUMP - #3
Austin Energy (AE), requires the services of a qualified pump repair service shop (hereinafter Vendor) that will repair and modify a ITT Gould’s 42XX52GHX0-1 Circulating Water Pump (hereinafter Circ. Pump), reference Attachment B. This pump was shutdown due to high vibrations during operation. The pump has been in service since October 2005. In 2005 the pump was repaired due to damage to the impeller and a stainless steel impeller was used to replace the original impeller. Disassemble, inspect, and develop a repair work scope based on the information given above. The contractor shall develop this using best practice or industry standards for a pump of this type and service. Recommend any modifications and modify pump to improve reliability.
The repair scope of work to be developed herein shall be for an ITT Gould’s 42XX52GHX0-1 Circulating Water Pump, Serial No.: 312910-1.
Model: VIT-FF
RPM: 590
GPM: 59,000
Head-FT: 83
| REPAIR AND MODIFY |
| UNIT 5 CIRCULATING WATER PUMP - #3 |