RFP_1100_MMH3041_0600_v1.pdf

PDF 103 KB Posted

Attached to
Utility Pump Maintenance and Replacement
Solicitation number
RFP 1100 MMH3041
Issued by
Texas

About this file

This is a sample work scope document issued by Austin Energy, a utility operated by the City of Austin, Texas, for the repair and modification of a vertical turbine pump at the Decker Creek Power Station. The scope of work requires a qualified pump repair service vendor to disassemble, inspect, and develop a comprehensive repair plan for a Byron Jackson Model 20 HQO pump with four stages (Serial Number 871-H-0004) that has been in continuous operation since its installation in 1987. The pump is critical infrastructure used to convey water from the Colorado River to the Walter E. Long Lake cooling reservoir that supports the power plant's operations. The pump station is located on FM 969 in Austin, Texas. The contractor must evaluate the pump's condition based on industry best practices and standards applicable to this pump type and service application, recommend modifications to enhance reliability, and implement the recommended improvements.

The contractor is expected to conduct a thorough evaluation and develop the repair scope independently, utilizing established industry standards and best practices for vertical turbine pump repair and maintenance. The document does not specify pricing terms, contract duration, response deadlines, or award dates, as this is a sample work scope rather than a complete RFP. This work scope is associated with Austin Energy's broader utility pump maintenance contract covering Sand Hill Energy Center, Decker Creek Power Station, and on-site energy resources across multiple facilities.

View the file

Other files

File Type Posted
RFP_1100_MMH3041_0500_v1.pdf PDF
RFP_1100_MMH3041_PAC1_v1.pdf PDF
RFP_1100_MMH3041_ROCIP_v1.pdf PDF
RFP_1100_MMH3041_BID_DOC_v1.docx DOCX document
RFP_1100_MMH3041_ATT_3_v1.pdf PDF
IFB_9100_AAM1023_PAC1_v1.pdf PDF
RFP_1100_MMH3041_PLANS_v1.pdf PDF
RFP_1100_MMH3041_MWDBE_PAC_v1.pdf PDF
RFP_1100_MMH3041_PAC2_v1.pdf PDF
RFP_1100_MMH3041_ATT_v1.pdf PDF
RFP_1100_MMH3041_ATT_2_v1.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHEMENT C

AUSTIN ENERGY

SAMPLE WORKSCOPE

FOR

REPAIR OF RIVER INTAKE PUMP #1

DECKER CREEK POWER STATION

Austin Energy requires the services of a qualified pump repair service shop (hereinafter Vendor) to repair and modify a Byron Jackson Model 20 HQO, Vertical Turbine type with 4 stages, S/N 871-H-0004. The pump was purchased and installed in 1987 and has been in service since. The pump is used to pump water from the Colorado River to the Walter E. Long Lake, which is the cooling reservoir for the power plant. The pump is installed in the Decker Creek River Pump Station on FM 969 in Austin, Texas. Disassemble, inspect, and develop a repair work scope based on the information given above. The contractor shall develop this using best practice or industry standards for a pump of this type and service. Recommend any modifications and modify pump to improve reliability