RFI_Att_3_PWS_DLSS Service Parts List.xlsx

XLSX spreadsheet 32 KB Posted

Attached to
DIVER LIFE SUPPORT SYSTEM MAINTENANCE SERVICES
Solicitation number
N0060426DLSS
Issued by

About this file

This is a Service Parts List for Diver Life Support Systems (DLSS) Maintenance Services supporting Explosive Ordnance Disposal Group One (EODGRU1) in San Diego, California. The document details the specific components, quantities, and maintenance intervals required to support the maintenance and repair of diving equipment over a one-year period. The list encompasses gas cylinder fills (HeO2 88/12%, O2 100%, and O2N2 60/40% mixtures), with 100 total gas cylinder fills at 50 refills each, plus associated cylinder fill fees including pickup, delivery, fuel surcharge, hazardous material handling, and driver retention charges.

The parts list specifies maintenance requirements for multiple equipment systems with defined maintenance intervals ranging from 18 to 72 months: Oxygen Transfer Pump Assembly (OTPA) systems requiring 3 units of maintenance; four Bauer O26-D air compressors necessitating filter cartridges, O-rings, backup rings, air intake filters, sintered filter elements, oil and filter assemblies, and compressor oil; five C-D/DV/Navy Compressors requiring air purifier elements and CO/moisture indicator elements; three Transportable Recompression Chamber Systems (TRCS) requiring gauge calibrations, relief valve testing, acrylic window inspections, T-filter elements, carbon fiber flask inspections and hydrostatic testing, rupture disc replacements, and hose testing; one Standard Navy Double Lock (SNDL) Recompression Chamber System requiring check valve testing, gauge calibrations, filter element replacements, oxygen reducing station maintenance, and carbon fiber flask inspections; one FADS III system requiring similar gauge calibrations and filter maintenance; one ORCA system; 200 relief valves; 300 SCUBA cylinders requiring 60-month hydrostatic testing; 400 DLSS gauges requiring 18-month and 24-month calibrations; and two Closed Circuit UBA Viper units requiring gauge and relief valve calibrations and pressure vessel hydrostatic testing at 60-month intervals. The anticipated contract period of performance is one 12-month base period beginning approximately June 1, 2026, with one 12-month option period.

View the file

Other files

File Type Posted
RFI_Att_2_PWS_DLSS.pdf PDF
RFI_Att_1_Description_DLSS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DLSS Service Parts List

EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE SERVICES SERVICE PARTS LIST
ITEM NO.ITEM DESCRIPTIONQTYCOMMENTSCOMMENTS 2
1Gas Cylinder Fill x 100

tc={49A60651-2C1D-48B9-832E-CB98FB641DD7}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

100 indicates there are 100 gas cylinder fills. 50 ea tc={419BBE41-DA10-4B45-9A15-D18094CF5ECD}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

50 each indicates each gas cylinder requires 50 gas refills.Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included)
2Gas Cylinder Fill x 10030 eaRefill O2 100% compressed gas cylinders (certificate of gas analysis included)
3Gas Cylinder Fill x 10020 eaRefill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included)
4Gas Cylinder Fill x 10010 eaVarious cylinder fill fees (pick up charge, delivery charge, fuel surcharge, hazardous material charge, driver retention charge)
5OTPA Maintenance x 33 ea24M Calibrate oxygen outlet pressure gauge OHP-G20124M indicates maintenance service is required every 24 months.
6OTPA Maintenance x 33 ea24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper24M indicates maintenance service is required every 24 months.
7OTPA Maintenance x 33 eaProvide air cycling valve kit (p/n 17329)
8OTPA Maintenance x 33 ea36M Test Oxygen Transfer Pump Assembly Relief Valves36M indicates maintenance service is required every 36 months.
9OTPA Maintenance x 33 ea36M Inspect Oxygen In-Line Filters36M indicates maintenance service is required every 36 months.
10OTPA Maintenance x 33 ea72M Deliver Oxygen Transfer Pump Assembly for Overhaul72M indicates maintenance service is required every 72 months.
11Bauer O26-D Maintenance x 4

tc={AB97C335-37E1-4CAE-B0B8-C3F12305CB36}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

4 indicates there are 4 Bauer O26-Ds. 2 ea tc={79FC2BB7-05EC-45C1-B7BD-BD79FFB39800}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

2 each indicates each Bauer compressor requires replacement 2 times.A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge
12Bauer O26-D Maintenance x 42 eaProvide drying filter cartridge (p/n 058825A)
13Bauer O26-D Maintenance x 48 eaProvide Securus filter cartridge (p/n 060037A)
14Bauer O26-D Maintenance x 416 eaProvide O-ring (p/n N04735)
15Bauer O26-D Maintenance x 416 eaProvide backup ring (p/n N04736)
16Bauer O26-D Maintenance x 44 eaProvide air intake filter (p/n N25886)
17Bauer O26-D Maintenance x 44 ea18M Calibrate Diver's Portable Gauges18M indicates maintenance service is required every 18 months.
18Bauer O26-D Maintenance x 420 hrs18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element
19Bauer O26-D Maintenance x 44 eaProvide sintered filter element (p/n 061860)18M indicates maintenance service is required every 18 months.
20Bauer O26-D Maintenance x 42 ea24M Change Oil and Replace Oil Tube/Filter Assembly24M indicates maintenance service is required every 24 months.
21Bauer O26-D Maintenance x 42 eaProvide oil filter (p/n N25326)
22Bauer O26-D Maintenance x 42 eaProvide gasket (p/n 077774)
23Bauer O26-D Maintenance x 42 eaProvide O-ring (p/n N04058)
24Bauer O26-D Maintenance x 42 eaProvide O-ring (p/n N25327)
25Bauer O26-D Maintenance x 48 gal

tc={A500EED9-9AD4-4D16-B5D1-335E710AB674}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

8 gal indicates that 8 gallons of oil are required for each Bauer compressor.

tc={AB97C335-37E1-4CAE-B0B8-C3F12305CB36}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

4 indicates there are 4 Bauer O26-Ds.

tc={79FC2BB7-05EC-45C1-B7BD-BD79FFB39800}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

2 each indicates each Bauer compressor requires replacement 2 times.Provide compressor oil (p/n OIL-0024)
26Bauer O26-D Maintenance x 44 ea24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves24M indicates maintenance service is required every 24 months.
27Bauer O26-D Maintenance x 44 eaProvide check valve (p/n VAL-0007)
28Bauer O26-D Maintenance x 48 eaProvide pressure maintaining valve (p/n VAL-0053)
29Bauer O26-D Maintenance x 44 ea36M Test Relief Valves Removed From System36M indicates maintenance service is required every 36 months.
30C-D/DV/Navy Compressor Maintenance x 55 eaA-10 Replace Bauer air purifier element
31C-D/DV/Navy Compressor Maintenance x 55 eaProvide air purifier element (p/n 058821A)
32C-D/DV/Navy Compressor Maintenance x 55 eaProvide O-ring (p/n N04735)
33C-D/DV/Navy Compressor Maintenance x 55 eaProvide backup ring (p/n N04736)
34C-D/DV/Navy Compressor Maintenance x 55 eaA-11 Change CO/Moisture indicator element
35C-D/DV/Navy Compressor Maintenance x 55 eaProvide moisture indicator element (p/n ELM-0056)
36C-D/DV/Navy Compressor Maintenance x 510 ea18M Calibrate Diver's Portable Gauges18M indicates maintenance service is required every 18 months.
37C-D/DV/Navy Compressor Maintenance x 55 ea36M Test Relief Valves Removed From System36M indicates maintenance service is required every 36 months.
38Transportable Recompression Chamber System (TRCS) x 372 ea24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite24M indicates maintenance service is required every 24 months.
39Transportable Recompression Chamber System (TRCS) x 318 eaLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)
40Transportable Recompression Chamber System (TRCS) x 318 eaProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)
41Transportable Recompression Chamber System (TRCS) x 35 eaProvide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge)
42Transportable Recompression Chamber System (TRCS) x 33 ea36M Perform Visual Inspection of Acrylic Window36M indicates maintenance service is required every 36 months.
43Transportable Recompression Chamber System (TRCS) x 324 ea36M Test Relief Valves Removed from System onsite36M indicates maintenance service is required every 36 months.
44Transportable Recompression Chamber System (TRCS) x 318 hrsLabor involved in TRCS calibration (relief valve removal, system line-ups, joint testing)
45Transportable Recompression Chamber System (TRCS) x 318 eaProvide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal)
46Transportable Recompression Chamber System (TRCS) x 315 hrs36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings36M indicates maintenance service is required every 36 months.
47Transportable Recompression Chamber System (TRCS) x 315 eaProvide Swagelok filter element (p/n M-8F-K4-15)
48Transportable Recompression Chamber System (TRCS) x 315 eaProvide Swagelok filter gasket (p/n SS-8TF-K2)
49Transportable Recompression Chamber System (TRCS) x 36 hrsClean filter elements and gaskets IAW MIL STD 1330E
50Transportable Recompression Chamber System (TRCS) x 312 hrs36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings36M indicates maintenance service is required every 36 months.
51Transportable Recompression Chamber System (TRCS) x 312 eaProvide Swagelok filter element (p/n M-8F-K4-15)
52Transportable Recompression Chamber System (TRCS) x 312 eaProvide Swagelok filter gasket (p/n SS-8TF-K2)
53Transportable Recompression Chamber System (TRCS) x 36 hrsClean filter elements and gaskets IAW MIL STD 1330E
54Transportable Recompression Chamber System (TRCS) x 336 ea60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement60M indicates maintenance service is required every 60 months.
55Transportable Recompression Chamber System (TRCS) x 336 hrsLabor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test
56Transportable Recompression Chamber System (TRCS) x 336 eaProvide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E
57Transportable Recompression Chamber System (TRCS) x 336 eaProvide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E
58Transportable Recompression Chamber System (TRCS) x 336 eaProvide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E
59Transportable Recompression Chamber System (TRCS) x 33 eaDiver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source)
60Transportable Recompression Chamber System (TRCS) x 33 ea60M Hydrostatically Test Fire Extinguisher60M indicates maintenance service is required every 60 months.
61Transportable Recompression Chamber System (TRCS) x 315 hrsU-2 Hydrostatically Test Hoses
62Transportable Recompression Chamber System (TRCS) x 324 hrsU-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings
63Transportable Recompression Chamber System (TRCS) x 39 hrsU-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers
64Transportable Recompression Chamber System (TRCS) x 312 hrsREC and OQE package
65SNDL Maintenance x 11 ea18M Test and Inspect ASRA Check Valve (AHP-V445).18M indicates maintenance service is required every 18 months.
66SNDL Maintenance x 122 ea24M Calibrate Diver's Life Support System (DLSS) Installed Gauges.24M indicates maintenance service is required every 24 months.
67SNDL Maintenance x 12 hrs36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element36M indicates maintenance service is required every 36 months.
68SNDL Maintenance x 12 eaProvide filter element (p/n U-10007)
69SNDL Maintenance x 12 hrsClean (2) filter elements IAW MIL STD 1622B
70SNDL Maintenance x 12 eaProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B
71SNDL Maintenance x 12 eaProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B
72SNDL Maintenance x 12 eaProvide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B
73SNDL Maintenance x 14 eaProvide M83248/2-908 O-rings, cleaned IAW MIL STD 1622B
74SNDL Maintenance x 14 hrs36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves.36M indicates maintenance service is required every 36 months.
75SNDL Maintenance x 110 hrsLabor involved in SNDL HP oxygen reducing station valve inspection (panel removal, piping removal/reinstallation, panel reinstallation, joint testing)
76SNDL Maintenance x 11 hrVisually inspect primary HP oxygen supply regulator OHP-R206 and secondary HP oxygen supply regulator OHP-R205 inlet screens
77SNDL Maintenance x 11 hrVisually inspect primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 outlets
78SNDL Maintenance x 14 hrsOverhaul primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203
79SNDL Maintenance x 12 eaProvide valve repair kit (p/n T-9K-6N)
80SNDL Maintenance x 12 hrClean (2) valve repair kits IAW MIL STD 1330E
81SNDL Maintenance x 11 hrPerform valve seat tightness test on primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203
82SNDL Maintenance x 17 ea36M Test Relief Valves Removed from System36M indicates maintenance service is required every 36 months.
83SNDL Maintenance x 13 ea36M Clean and Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) T-Filter Elements and Housings36M indicates maintenance service is required every 36 months.
84SNDL Maintenance x 13 eaProvide Swagelok filter element (p/n M-8F-K4-15)
85SNDL Maintenance x 13 eaProvide Swagelok filter gaskets (p/n SS-8TF-K2)
86SNDL Maintenance x 13 hrClean (3) filters and (3) gaskets IAW MIL STD 1330E
87SNDL Maintenance x 13 hrs36M Clean and Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) LP In-Line Filter Element36M indicates maintenance service is required every 36 months.
88SNDL Maintenance x 12 eaProvide Norman filter element (p/n 416G-20VN)
89SNDL Maintenance x 12 hrsClean (2) filter elements IAW MIL STD 1622B
90SNDL Maintenance x 14 eaProvide M83248/2-924 O-rings, cleaned IAW MIL STD 1622B
91SNDL Maintenance x 14 eaProvide M83248/2-912 O-rings, cleaned IAW MIL STD 1622B
92SNDL Maintenance x 18 eaProvide M83248/2-021 O-rings, cleaned IAW MIL STD 1622B
93SNDL Maintenance x 12 hrs36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA36M indicates maintenance service is required every 36 months.
94SNDL Maintenance x 12 eaProvide filter element (p/n U-10007)
95SNDL Maintenance x 12 hrsClean (2) filter elements IAW MIL STD 1622B
96SNDL Maintenance x 14 eaProvide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B
97SNDL Maintenance x 14 eaProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B
98SNDL Maintenance x 12 eaProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B
99SNDL Maintenance x 19 ea60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement60M indicates maintenance service is required every 60 months.
100SNDL Maintenance x 116 hrsLabor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test
101SNDL Maintenance x 19 eaProvide rupture discs (p/n 128450XX)
102SNDL Maintenance x 19 hrsClean (9) rupture discs IAW MIL STD 1622B
103SNDL Maintenance x 115 eaProvide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D
104SNDL Maintenance x 118 eaProvide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D
105SNDL Maintenance x 117 eaProvide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D
106SNDL Maintenance x 11 eaDiver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source)
107SNDL Maintenance x 110 hrsU-2 Hydrostatically Test Hose
108SNDL Maintenance x 12 hrsU-4 Repair or Replace ASRA Check Valve (AHP-V445) and Conduct Tightness Tests
109SNDL Maintenance x 11 eaProvide Swagelok check valve (p/n SS-CHVCO8-5)
110SNDL Maintenance x 11 hrU-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffuser(s)/Silencer
111SNDL Maintenance x 14 hrsREC and OQE package
112FADS III Maintenance x 112 ea24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite24M indicates maintenance service is required every 24 months.
113FADS III Maintenance x 11 hrs36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements36M indicates maintenance service is required every 36 months.
114FADS III Maintenance x 11 eaProvide filter element (p/n U-10007)
115FADS III Maintenance x 14 hrsClean (4) filter elements IAW MIL STD 1622B
116FADS III Maintenance x 16 eaProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B
117FADS III Maintenance x 11 eaProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B
118FADS III Maintenance x 12 eaProvide M83248/2-111 O-rings, cleaned IAW MIL STD 1622B
119FADS III Maintenance x 14 ea36M Test Relief Valves Removed from System onsite36M indicates maintenance service is required every 36 months.
120FADS III Maintenance x 11 hrs36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA36M indicates maintenance service is required every 36 months.
121FADS III Maintenance x 11 eaProvide filter element (p/n U-10007)
122FADS III Maintenance x 14 hrsClean (4) filter elements IAW MIL STD 1622B
123FADS III Maintenance x 12 eaProvide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B
124FADS III Maintenance x 11 eaProvide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B
125FADS III Maintenance x 11 eaProvide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B
126FADS III Maintenance x 19 ea60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement60M indicates maintenance service is required every 60 months.
127FADS III Maintenance x 116 hrsLabor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test
128FADS III Maintenance x 19 eaProvide rupture discs (p/n 128450XX)
129FADS III Maintenance x 19 hrsClean (9) rupture discs IAW MIL STD 1622B
130FADS III Maintenance x 115 eaProvide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D
131FADS III Maintenance x 118 eaProvide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D
132FADS III Maintenance x 117 eaProvide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D
133FADS III Maintenance x 11 eaDiver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source)
134FADS III Maintenance x 15 hrsU-2 Hydrostatically Test Hoses
135FADS III Maintenance x 14 hrsREC and OQE package
136ORCA Maintenance x 12 ea24M Calibrate Diver's Life Support System (DLSS) Installed Gauges24M indicates maintenance service is required every 24 months.
137ORCA Maintenance x 11 ea36M Test Relief Valves Removed From System36M indicates maintenance service is required every 36 months.
138ORCA Maintenance x 13 hrs36M Clean and Inspect Oxygen Regulating Console Assembly (ORCA) I & II Inline Filter Elements36M indicates maintenance service is required every 36 months.
139ORCA Maintenance x 12 hrsU-2 Hydrostatically Test Hoses
140ORCA Maintenance x 12 hrsREC and OQE package
141Relief Valves x 200200 ea36M Test Relief Valves Removed from System onsite36M indicates maintenance service is required every 36 months.
142SCUBA Cylinders x 300300 ea60M Hydrostatic test SCUBA cylinders60M indicates maintenance service is required every 60 months.
143DLSS Gauges x 400200 ea18M 6R Calibrate Diver's Life Support System (DLSS) Portable Gauges18M indicates maintenance service is required every 18 months.
144DLSS Gauges x 400200 ea24M Calibrate Diver's Life Support System (DLSS) Installed Gauges24M indicates maintenance service is required every 24 months.
145Closed Circuit UBA Viper x 22 ea24M Calibrate Test Panel Gages, Relief Valve, and Conduct Comparison Accuracy Test for Flowmeters and Pocket Flowmeters.24M indicates maintenance service is required every 24 months.
146Closed Circuit UBA Viper x 21 hrs60M Deliver Pressure Vessels to an Authorized Activity for Hydrostatic Testing.60M indicates maintenance service is required every 60 months.

100 indicates there are 100 gas cylinder fills.

50 each indicates each gas cylinder requires 50 gas refills.

4 indicates there are 4 Bauer O26-Ds.

2 each indicates each Bauer compressor requires replacement 2 times.

8 gal indicates that 8 gallons of oil are required for each Bauer compressor.

File details come from the government source that posted it. Updated .