This is a Service Parts List for Diver Life Support Systems (DLSS) Maintenance Services supporting Explosive Ordnance Disposal Group One (EODGRU1) in San Diego, California. The document details the specific components, quantities, and maintenance intervals required to support the maintenance and repair of diving equipment over a one-year period. The list encompasses gas cylinder fills (HeO2 88/12%, O2 100%, and O2N2 60/40% mixtures), with 100 total gas cylinder fills at 50 refills each, plus associated cylinder fill fees including pickup, delivery, fuel surcharge, hazardous material handling, and driver retention charges.
The parts list specifies maintenance requirements for multiple equipment systems with defined maintenance intervals ranging from 18 to 72 months: Oxygen Transfer Pump Assembly (OTPA) systems requiring 3 units of maintenance; four Bauer O26-D air compressors necessitating filter cartridges, O-rings, backup rings, air intake filters, sintered filter elements, oil and filter assemblies, and compressor oil; five C-D/DV/Navy Compressors requiring air purifier elements and CO/moisture indicator elements; three Transportable Recompression Chamber Systems (TRCS) requiring gauge calibrations, relief valve testing, acrylic window inspections, T-filter elements, carbon fiber flask inspections and hydrostatic testing, rupture disc replacements, and hose testing; one Standard Navy Double Lock (SNDL) Recompression Chamber System requiring check valve testing, gauge calibrations, filter element replacements, oxygen reducing station maintenance, and carbon fiber flask inspections; one FADS III system requiring similar gauge calibrations and filter maintenance; one ORCA system; 200 relief valves; 300 SCUBA cylinders requiring 60-month hydrostatic testing; 400 DLSS gauges requiring 18-month and 24-month calibrations; and two Closed Circuit UBA Viper units requiring gauge and relief valve calibrations and pressure vessel hydrostatic testing at 60-month intervals. The anticipated contract period of performance is one 12-month base period beginning approximately June 1, 2026, with one 12-month option period.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI_Att_2_PWS_DLSS.pdf | ||
| RFI_Att_1_Description_DLSS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DLSS Service Parts List
| EODGRU1 DIVERS LIFE SUPPORT SYSTEMS (DLSS) MAINTENANCE SERVICES SERVICE PARTS LIST | ||||
| ITEM NO. | ITEM DESCRIPTION | QTY | COMMENTS | COMMENTS 2 |
| 1 | Gas Cylinder Fill x 100 |
tc={49A60651-2C1D-48B9-832E-CB98FB641DD7}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
100 indicates there are 100 gas cylinder fills. 50 ea tc={419BBE41-DA10-4B45-9A15-D18094CF5ECD}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
| 50 each indicates each gas cylinder requires 50 gas refills. | Refill HeO2 88/12% compressed gas cylinders (certificate of gas analysis included) | ||||
| 2 | Gas Cylinder Fill x 100 | 30 ea | Refill O2 100% compressed gas cylinders (certificate of gas analysis included) | ||
| 3 | Gas Cylinder Fill x 100 | 20 ea | Refill O2N2 60/40% compressed gas cylinders (certificate of gas analysis included) | ||
| 4 | Gas Cylinder Fill x 100 | 10 ea | Various cylinder fill fees (pick up charge, delivery charge, fuel surcharge, hazardous material charge, driver retention charge) | ||
| 5 | OTPA Maintenance x 3 | 3 ea | 24M Calibrate oxygen outlet pressure gauge OHP-G201 | 24M indicates maintenance service is required every 24 months. | |
| 6 | OTPA Maintenance x 3 | 3 ea | 24M Replace Pump Assembly Air Cycling Valve O-rings and Bumper | 24M indicates maintenance service is required every 24 months. | |
| 7 | OTPA Maintenance x 3 | 3 ea | Provide air cycling valve kit (p/n 17329) | ||
| 8 | OTPA Maintenance x 3 | 3 ea | 36M Test Oxygen Transfer Pump Assembly Relief Valves | 36M indicates maintenance service is required every 36 months. | |
| 9 | OTPA Maintenance x 3 | 3 ea | 36M Inspect Oxygen In-Line Filters | 36M indicates maintenance service is required every 36 months. | |
| 10 | OTPA Maintenance x 3 | 3 ea | 72M Deliver Oxygen Transfer Pump Assembly for Overhaul | 72M indicates maintenance service is required every 72 months. | |
| 11 | Bauer O26-D Maintenance x 4 |
tc={AB97C335-37E1-4CAE-B0B8-C3F12305CB36}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
4 indicates there are 4 Bauer O26-Ds. 2 ea tc={79FC2BB7-05EC-45C1-B7BD-BD79FFB39800}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
| 2 each indicates each Bauer compressor requires replacement 2 times. | A-2 Replace Air Purifier (SECURUS) Cartridge, Drying Filter Cartridge, and CO Filter Cartridge | ||||
| 12 | Bauer O26-D Maintenance x 4 | 2 ea | Provide drying filter cartridge (p/n 058825A) | ||
| 13 | Bauer O26-D Maintenance x 4 | 8 ea | Provide Securus filter cartridge (p/n 060037A) | ||
| 14 | Bauer O26-D Maintenance x 4 | 16 ea | Provide O-ring (p/n N04735) | ||
| 15 | Bauer O26-D Maintenance x 4 | 16 ea | Provide backup ring (p/n N04736) | ||
| 16 | Bauer O26-D Maintenance x 4 | 4 ea | Provide air intake filter (p/n N25886) | ||
| 17 | Bauer O26-D Maintenance x 4 | 4 ea | 18M Calibrate Diver's Portable Gauges | 18M indicates maintenance service is required every 18 months. | |
| 18 | Bauer O26-D Maintenance x 4 | 20 hrs | 18M Disassemble, Clean, Inspect and Reassemble Sintered Metal Filter or Helical Insert Bauer Oil and Water Separator Element | ||
| 19 | Bauer O26-D Maintenance x 4 | 4 ea | Provide sintered filter element (p/n 061860) | 18M indicates maintenance service is required every 18 months. | |
| 20 | Bauer O26-D Maintenance x 4 | 2 ea | 24M Change Oil and Replace Oil Tube/Filter Assembly | 24M indicates maintenance service is required every 24 months. | |
| 21 | Bauer O26-D Maintenance x 4 | 2 ea | Provide oil filter (p/n N25326) | ||
| 22 | Bauer O26-D Maintenance x 4 | 2 ea | Provide gasket (p/n 077774) | ||
| 23 | Bauer O26-D Maintenance x 4 | 2 ea | Provide O-ring (p/n N04058) | ||
| 24 | Bauer O26-D Maintenance x 4 | 2 ea | Provide O-ring (p/n N25327) | ||
| 25 | Bauer O26-D Maintenance x 4 | 8 gal |
tc={A500EED9-9AD4-4D16-B5D1-335E710AB674}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
8 gal indicates that 8 gallons of oil are required for each Bauer compressor.
tc={AB97C335-37E1-4CAE-B0B8-C3F12305CB36}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
4 indicates there are 4 Bauer O26-Ds.
tc={79FC2BB7-05EC-45C1-B7BD-BD79FFB39800}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
| 2 each indicates each Bauer compressor requires replacement 2 times. | Provide compressor oil (p/n OIL-0024) | ||||
| 26 | Bauer O26-D Maintenance x 4 | 4 ea | 24M Replace Bauer Air Compressor Pressure Maintaining Valve (PMV) and Inlet/Outlet Check Valves | 24M indicates maintenance service is required every 24 months. | |
| 27 | Bauer O26-D Maintenance x 4 | 4 ea | Provide check valve (p/n VAL-0007) | ||
| 28 | Bauer O26-D Maintenance x 4 | 8 ea | Provide pressure maintaining valve (p/n VAL-0053) | ||
| 29 | Bauer O26-D Maintenance x 4 | 4 ea | 36M Test Relief Valves Removed From System | 36M indicates maintenance service is required every 36 months. | |
| 30 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | A-10 Replace Bauer air purifier element | ||
| 31 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | Provide air purifier element (p/n 058821A) | ||
| 32 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | Provide O-ring (p/n N04735) | ||
| 33 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | Provide backup ring (p/n N04736) | ||
| 34 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | A-11 Change CO/Moisture indicator element | ||
| 35 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | Provide moisture indicator element (p/n ELM-0056) | ||
| 36 | C-D/DV/Navy Compressor Maintenance x 5 | 10 ea | 18M Calibrate Diver's Portable Gauges | 18M indicates maintenance service is required every 18 months. | |
| 37 | C-D/DV/Navy Compressor Maintenance x 5 | 5 ea | 36M Test Relief Valves Removed From System | 36M indicates maintenance service is required every 36 months. | |
| 38 | Transportable Recompression Chamber System (TRCS) x 3 | 72 ea | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | 24M indicates maintenance service is required every 24 months. | |
| 39 | Transportable Recompression Chamber System (TRCS) x 3 | 18 ea | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | ||
| 40 | Transportable Recompression Chamber System (TRCS) x 3 | 18 ea | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | ||
| 41 | Transportable Recompression Chamber System (TRCS) x 3 | 5 ea | Provide AS3581-010 O-rings, cleaned IAW MIL STD 1330D (for TRCS med-lock gauge) | ||
| 42 | Transportable Recompression Chamber System (TRCS) x 3 | 3 ea | 36M Perform Visual Inspection of Acrylic Window | 36M indicates maintenance service is required every 36 months. | |
| 43 | Transportable Recompression Chamber System (TRCS) x 3 | 24 ea | 36M Test Relief Valves Removed from System onsite | 36M indicates maintenance service is required every 36 months. | |
| 44 | Transportable Recompression Chamber System (TRCS) x 3 | 18 hrs | Labor involved in TRCS calibration (relief valve removal, system line-ups, joint testing) | ||
| 45 | Transportable Recompression Chamber System (TRCS) x 3 | 18 ea | Provide AS3581-111 O-rings, cleaned IAW MIL STD 1330D (for TRCS relief valve removal) | ||
| 46 | Transportable Recompression Chamber System (TRCS) x 3 | 15 hrs | 36M Clean and Inspect Transportable Recompression Chamber (TRC) T-Filter Elements and Housings | 36M indicates maintenance service is required every 36 months. | |
| 47 | Transportable Recompression Chamber System (TRCS) x 3 | 15 ea | Provide Swagelok filter element (p/n M-8F-K4-15) | ||
| 48 | Transportable Recompression Chamber System (TRCS) x 3 | 15 ea | Provide Swagelok filter gasket (p/n SS-8TF-K2) | ||
| 49 | Transportable Recompression Chamber System (TRCS) x 3 | 6 hrs | Clean filter elements and gaskets IAW MIL STD 1330E | ||
| 50 | Transportable Recompression Chamber System (TRCS) x 3 | 12 hrs | 36M Clean and Inspect Transfer Lock (TL) T-Filter Elements and Housings | 36M indicates maintenance service is required every 36 months. | |
| 51 | Transportable Recompression Chamber System (TRCS) x 3 | 12 ea | Provide Swagelok filter element (p/n M-8F-K4-15) | ||
| 52 | Transportable Recompression Chamber System (TRCS) x 3 | 12 ea | Provide Swagelok filter gasket (p/n SS-8TF-K2) | ||
| 53 | Transportable Recompression Chamber System (TRCS) x 3 | 6 hrs | Clean filter elements and gaskets IAW MIL STD 1330E | ||
| 54 | Transportable Recompression Chamber System (TRCS) x 3 | 36 ea | 60M Perform DOT .93 Carbon Fiber Flask(s) External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 60M indicates maintenance service is required every 60 months. | |
| 55 | Transportable Recompression Chamber System (TRCS) x 3 | 36 hrs | Labor to disassemble and reassemble (4) flask racks assemblies while maintaining cleanliness IAW MIL STD 1330E, including filling flasks for 24 hour joint tightness drop test | ||
| 56 | Transportable Recompression Chamber System (TRCS) x 3 | 36 ea | Provide rupture discs (p/n 20Z), cleaned IAW MIL STD1330E | ||
| 57 | Transportable Recompression Chamber System (TRCS) x 3 | 36 ea | Provide M83248/2-916 o-rings, cleaned IAW MIL STD 1330E | ||
| 58 | Transportable Recompression Chamber System (TRCS) x 3 | 36 ea | Provide M83248/2-010 O-rings, cleaned IAW MIL STD 1330E | ||
| 59 | Transportable Recompression Chamber System (TRCS) x 3 | 3 ea | Diver’s air gas required for flask rack joint tightness test (leave flasks full and provide current satisfactory air sample from diver’s air source) | ||
| 60 | Transportable Recompression Chamber System (TRCS) x 3 | 3 ea | 60M Hydrostatically Test Fire Extinguisher | 60M indicates maintenance service is required every 60 months. | |
| 61 | Transportable Recompression Chamber System (TRCS) x 3 | 15 hrs | U-2 Hydrostatically Test Hoses | ||
| 62 | Transportable Recompression Chamber System (TRCS) x 3 | 24 hrs | U-3 Clean and Inspect Interlock Poppet and NATO Flange Bearings | ||
| 63 | Transportable Recompression Chamber System (TRCS) x 3 | 9 hrs | U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffusers/Silencers | ||
| 64 | Transportable Recompression Chamber System (TRCS) x 3 | 12 hrs | REC and OQE package | ||
| 65 | SNDL Maintenance x 1 | 1 ea | 18M Test and Inspect ASRA Check Valve (AHP-V445). | 18M indicates maintenance service is required every 18 months. | |
| 66 | SNDL Maintenance x 1 | 22 ea | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges. | 24M indicates maintenance service is required every 24 months. | |
| 67 | SNDL Maintenance x 1 | 2 hrs | 36M Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) HP In-Line Air Reducing Station Filter Element | 36M indicates maintenance service is required every 36 months. | |
| 68 | SNDL Maintenance x 1 | 2 ea | Provide filter element (p/n U-10007) | ||
| 69 | SNDL Maintenance x 1 | 2 hrs | Clean (2) filter elements IAW MIL STD 1622B | ||
| 70 | SNDL Maintenance x 1 | 2 ea | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | ||
| 71 | SNDL Maintenance x 1 | 2 ea | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | ||
| 72 | SNDL Maintenance x 1 | 2 ea | Provide M83248/2-015 O-rings, cleaned IAW MIL STD 1622B | ||
| 73 | SNDL Maintenance x 1 | 4 ea | Provide M83248/2-908 O-rings, cleaned IAW MIL STD 1622B | ||
| 74 | SNDL Maintenance x 1 | 4 hrs | 36M Clean, Inspect and Test Standard Navy Double Lock (SNDL) HP Oxygen Reducing Station Piping and Valves. | 36M indicates maintenance service is required every 36 months. | |
| 75 | SNDL Maintenance x 1 | 10 hrs | Labor involved in SNDL HP oxygen reducing station valve inspection (panel removal, piping removal/reinstallation, panel reinstallation, joint testing) | ||
| 76 | SNDL Maintenance x 1 | 1 hr | Visually inspect primary HP oxygen supply regulator OHP-R206 and secondary HP oxygen supply regulator OHP-R205 inlet screens | ||
| 77 | SNDL Maintenance x 1 | 1 hr | Visually inspect primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 outlets | ||
| 78 | SNDL Maintenance x 1 | 4 hrs | Overhaul primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 | ||
| 79 | SNDL Maintenance x 1 | 2 ea | Provide valve repair kit (p/n T-9K-6N) | ||
| 80 | SNDL Maintenance x 1 | 2 hr | Clean (2) valve repair kits IAW MIL STD 1330E | ||
| 81 | SNDL Maintenance x 1 | 1 hr | Perform valve seat tightness test on primary oxygen supply valve OHP-V201 and secondary oxygen supply valve OHP-V203 | ||
| 82 | SNDL Maintenance x 1 | 7 ea | 36M Test Relief Valves Removed from System | 36M indicates maintenance service is required every 36 months. | |
| 83 | SNDL Maintenance x 1 | 3 ea | 36M Clean and Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) T-Filter Elements and Housings | 36M indicates maintenance service is required every 36 months. | |
| 84 | SNDL Maintenance x 1 | 3 ea | Provide Swagelok filter element (p/n M-8F-K4-15) | ||
| 85 | SNDL Maintenance x 1 | 3 ea | Provide Swagelok filter gaskets (p/n SS-8TF-K2) | ||
| 86 | SNDL Maintenance x 1 | 3 hr | Clean (3) filters and (3) gaskets IAW MIL STD 1330E | ||
| 87 | SNDL Maintenance x 1 | 3 hrs | 36M Clean and Inspect Standard Navy Double Lock Recompression Chamber System (SNDLRCS) LP In-Line Filter Element | 36M indicates maintenance service is required every 36 months. | |
| 88 | SNDL Maintenance x 1 | 2 ea | Provide Norman filter element (p/n 416G-20VN) | ||
| 89 | SNDL Maintenance x 1 | 2 hrs | Clean (2) filter elements IAW MIL STD 1622B | ||
| 90 | SNDL Maintenance x 1 | 4 ea | Provide M83248/2-924 O-rings, cleaned IAW MIL STD 1622B | ||
| 91 | SNDL Maintenance x 1 | 4 ea | Provide M83248/2-912 O-rings, cleaned IAW MIL STD 1622B | ||
| 92 | SNDL Maintenance x 1 | 8 ea | Provide M83248/2-021 O-rings, cleaned IAW MIL STD 1622B | ||
| 93 | SNDL Maintenance x 1 | 2 hrs | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | 36M indicates maintenance service is required every 36 months. | |
| 94 | SNDL Maintenance x 1 | 2 ea | Provide filter element (p/n U-10007) | ||
| 95 | SNDL Maintenance x 1 | 2 hrs | Clean (2) filter elements IAW MIL STD 1622B | ||
| 96 | SNDL Maintenance x 1 | 4 ea | Provide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B | ||
| 97 | SNDL Maintenance x 1 | 4 ea | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | ||
| 98 | SNDL Maintenance x 1 | 2 ea | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | ||
| 99 | SNDL Maintenance x 1 | 9 ea | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 60M indicates maintenance service is required every 60 months. | |
| 100 | SNDL Maintenance x 1 | 16 hrs | Labor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test | ||
| 101 | SNDL Maintenance x 1 | 9 ea | Provide rupture discs (p/n 128450XX) | ||
| 102 | SNDL Maintenance x 1 | 9 hrs | Clean (9) rupture discs IAW MIL STD 1622B | ||
| 103 | SNDL Maintenance x 1 | 15 ea | Provide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D | ||
| 104 | SNDL Maintenance x 1 | 18 ea | Provide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D | ||
| 105 | SNDL Maintenance x 1 | 17 ea | Provide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D | ||
| 106 | SNDL Maintenance x 1 | 1 ea | Diver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source) | ||
| 107 | SNDL Maintenance x 1 | 10 hrs | U-2 Hydrostatically Test Hose | ||
| 108 | SNDL Maintenance x 1 | 2 hrs | U-4 Repair or Replace ASRA Check Valve (AHP-V445) and Conduct Tightness Tests | ||
| 109 | SNDL Maintenance x 1 | 1 ea | Provide Swagelok check valve (p/n SS-CHVCO8-5) | ||
| 110 | SNDL Maintenance x 1 | 1 hr | U-5 Clean, Inspect and Reinstall or Replace Air Supply and Exhaust Diffuser(s)/Silencer | ||
| 111 | SNDL Maintenance x 1 | 4 hrs | REC and OQE package | ||
| 112 | FADS III Maintenance x 1 | 12 ea | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges onsite | 24M indicates maintenance service is required every 24 months. | |
| 113 | FADS III Maintenance x 1 | 1 hrs | 36M Clean and Inspect Control Console Assembly (CCA) HP In-Line Air Filter Elements | 36M indicates maintenance service is required every 36 months. | |
| 114 | FADS III Maintenance x 1 | 1 ea | Provide filter element (p/n U-10007) | ||
| 115 | FADS III Maintenance x 1 | 4 hrs | Clean (4) filter elements IAW MIL STD 1622B | ||
| 116 | FADS III Maintenance x 1 | 6 ea | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | ||
| 117 | FADS III Maintenance x 1 | 1 ea | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | ||
| 118 | FADS III Maintenance x 1 | 2 ea | Provide M83248/2-111 O-rings, cleaned IAW MIL STD 1622B | ||
| 119 | FADS III Maintenance x 1 | 4 ea | 36M Test Relief Valves Removed from System onsite | 36M indicates maintenance service is required every 36 months. | |
| 120 | FADS III Maintenance x 1 | 1 hrs | 36M Remove, Clean, Inspect, Re-Use or Replace Charge Port and HP Regulator Filters of ASRA/OSRA/HOSRA and SCUBA | 36M indicates maintenance service is required every 36 months. | |
| 121 | FADS III Maintenance x 1 | 1 ea | Provide filter element (p/n U-10007) | ||
| 122 | FADS III Maintenance x 1 | 4 hrs | Clean (4) filter elements IAW MIL STD 1622B | ||
| 123 | FADS III Maintenance x 1 | 2 ea | Provide M83248/2-012 O-rings, cleaned IAW MIL STD 1622B | ||
| 124 | FADS III Maintenance x 1 | 1 ea | Provide M83248/2-906 O-rings, cleaned IAW MIL STD 1622B | ||
| 125 | FADS III Maintenance x 1 | 1 ea | Provide M83248/2-914 O-rings, cleaned IAW MIL STD 1622B | ||
| 126 | FADS III Maintenance x 1 | 9 ea | 60M Perform DOT 3.15 Carbon Fiber Flasks External and Internal Inspection, Hydrostatic Testing and Rupture Disc Replacement | 60M indicates maintenance service is required every 60 months. | |
| 127 | FADS III Maintenance x 1 | 16 hrs | Labor to disassemble, remove, reassemble, and reinstall flasks while maintaining cleanliness, including filling flasks for 24 hour joint tightness drop test | ||
| 128 | FADS III Maintenance x 1 | 9 ea | Provide rupture discs (p/n 128450XX) | ||
| 129 | FADS III Maintenance x 1 | 9 hrs | Clean (9) rupture discs IAW MIL STD 1622B | ||
| 130 | FADS III Maintenance x 1 | 15 ea | Provide M83248/2-111 o-rings, cleaned IAW MIL STD 1330D | ||
| 131 | FADS III Maintenance x 1 | 18 ea | Provide M83248/2-910 o-rings, cleaned IAW MIL STD 1330D | ||
| 132 | FADS III Maintenance x 1 | 17 ea | Provide M83248/2-010 o-rings, cleaned IAW MIL STD 1330D | ||
| 133 | FADS III Maintenance x 1 | 1 ea | Diver’s air gas required for joint tightness/24hr drop test (leave flasks full and provide current satisfactory air sample from diver’s air source) | ||
| 134 | FADS III Maintenance x 1 | 5 hrs | U-2 Hydrostatically Test Hoses | ||
| 135 | FADS III Maintenance x 1 | 4 hrs | REC and OQE package | ||
| 136 | ORCA Maintenance x 1 | 2 ea | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 24M indicates maintenance service is required every 24 months. | |
| 137 | ORCA Maintenance x 1 | 1 ea | 36M Test Relief Valves Removed From System | 36M indicates maintenance service is required every 36 months. | |
| 138 | ORCA Maintenance x 1 | 3 hrs | 36M Clean and Inspect Oxygen Regulating Console Assembly (ORCA) I & II Inline Filter Elements | 36M indicates maintenance service is required every 36 months. | |
| 139 | ORCA Maintenance x 1 | 2 hrs | U-2 Hydrostatically Test Hoses | ||
| 140 | ORCA Maintenance x 1 | 2 hrs | REC and OQE package | ||
| 141 | Relief Valves x 200 | 200 ea | 36M Test Relief Valves Removed from System onsite | 36M indicates maintenance service is required every 36 months. | |
| 142 | SCUBA Cylinders x 300 | 300 ea | 60M Hydrostatic test SCUBA cylinders | 60M indicates maintenance service is required every 60 months. | |
| 143 | DLSS Gauges x 400 | 200 ea | 18M 6R Calibrate Diver's Life Support System (DLSS) Portable Gauges | 18M indicates maintenance service is required every 18 months. | |
| 144 | DLSS Gauges x 400 | 200 ea | 24M Calibrate Diver's Life Support System (DLSS) Installed Gauges | 24M indicates maintenance service is required every 24 months. | |
| 145 | Closed Circuit UBA Viper x 2 | 2 ea | 24M Calibrate Test Panel Gages, Relief Valve, and Conduct Comparison Accuracy Test for Flowmeters and Pocket Flowmeters. | 24M indicates maintenance service is required every 24 months. | |
| 146 | Closed Circuit UBA Viper x 2 | 1 hrs | 60M Deliver Pressure Vessels to an Authorized Activity for Hydrostatic Testing. | 60M indicates maintenance service is required every 60 months. |
100 indicates there are 100 gas cylinder fills.
50 each indicates each gas cylinder requires 50 gas refills.
4 indicates there are 4 Bauer O26-Ds.
2 each indicates each Bauer compressor requires replacement 2 times.
8 gal indicates that 8 gallons of oil are required for each Bauer compressor.