RFB950400-02 - Drawings.pdf

PDF 4 MB Posted

Attached to
WRC Food Service Elevator Replacement
Solicitation number
RFB950400-02
Issued by
Dallas County, Iowa

About this file

This is a technical drawings document prepared by OPN Architects for the State of Iowa related to RFB950400-02, a food service elevator replacement project at the Woodward Resource Center located at 1251 334th Street, Woodward, Iowa 50276. The project involves the complete replacement of an existing hydraulic elevator system serving two levels (basement and first floor) of the facility. The scope of work includes demolition of existing elevator machinery, hoistway doors, and related equipment; installation of new elevator equipment including the cab, doors, controllers, and hydraulic systems; and associated mechanical, electrical, and fire safety modifications. The existing elevator shaft, rails, and sump pit will be retained and reused. The project drawings indicate coordination requirements among multiple consultants including Story Construction (general contractor), KCL Engineering (mechanical and electrical engineers), and Lerch Bates (elevator consultant and construction manager). The bid set is dated June 16, 2026.

The project must comply with the 2024 International Building Code as adopted by Iowa, the 2024 International Fire Code, the 2026 Iowa State Elevator Code, State Mechanical Code, State Plumbing Code, State Electrical Code, and the 2010 Americans with Disabilities Act. The work is limited in scope with minimal new construction; existing building use and occupancy classifications remain unchanged. The facility must maintain operational access throughout construction, with contractor parking limited to four vehicles and coordination required with facility operations. The building is not fully sprinklered, and the existing elevator machine room and shaft will remain non-sprinklered per project intent. All fire-rated penetrations must be sealed appropriately, and existing interior finishes must be matched or protected in place during construction.

View the file

Other files

File Type Posted
RFB950400-02 - Project Manual.pdf PDF
RFB950400-02 - Bid Form.pdf PDF
RFB950400-02 - Notice to Bidders.pdf PDF
RFB950400-02 - Addendum #1.pdf PDF
1431402-event.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IBC Chapter 2 - Use and Occupancy Classification

Primary Occupancy:

The use and occupancy classification of the existing building are unchanged.

IBC Chapter 5 - General Building Heights and Areas

Existing building use and size to remain unchanged.

IBC Chapter 6 - Types of Construction The type of construction for the existing building is unchanged.

IBC Chaper 7 - Fire and Smoke Protection Features

New construction is limited and existing construction is not being modified.

For construction purposes, shaft is considered to be 2 HR construction.

IBC Chapter 8 - Interior Finishes

New construction is limited and matches existing interior finishes.

IBC Chapter 10 - Means of Egress

All means of egress are being maintained in the existing building.

IBC Chapter 30 - Elevators and Conveying Systems

Fire resistance rated construction is provided at the elevator machine room.

Smoke protection at hoistway openings is not required per IBC 3006.2.

IBE Chapter 34 Existing Structures:

The updates to the existing building conform to the requirements of the code for new construction and are to be made with the same materials of which the original building is constructed. The existing building is in compliance with the mandatory fire safety requirements, the mandatory means of egress requirements, and the general safety requirements of this chapter.

Iowa Administrative Code, Chapter 16, Division VII - Accessibility Requirements For Facilities Used by the General Public:

Accessibility within the building will be maintained.

Iowa Administrative Code, Chapter 72 - Conveyances Installed on or After January 1, 1975 Elevator pit sump pump currently exists, and will be maintained.

NFPA-13 Chapter 8 - Section 8.15.5

Building is NOT fully sprinklered. The existing machine room and elevator shaft are not sprinklered and intent of project would be to maintain that condition.

APPLICABLE CODE INFORMATION

THE PROJECT SHALL COMPLY WITH THE FOLLOWING CODES

2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280 AND 481-301

2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTER 481-301

STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-426

STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-425

2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280

STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL LICENSING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481-404

2024 INTERNATIONAL EXISTING BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-301

2026 IOWA STATE ELEVATOR CODE

100 Court Ave. Suite 100, Des Moines, IA 50309

P: 515-309-0722 F: 515-309-0725 www.opnarchitects.com

ARCHITECT

OPN ARCHITECTS

100 COURT AVENUE

DES MOINES, IA 50309

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

ELEVATOR CONSULTANTMECHANICAL ENGINEER

KCL ENGINEERING

300 4th STREET

WEST DES MOINES, IA 50317

ELECTRICAL ENGINEER

KCL ENGINEERING

300 4th STREET

WEST DES MOINES, IA 50317

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE, SUITE T

EDEN PRAIRIE, MN 55344

STATE OF IOWA - 9504.00 - WRC FOOD SERVICE

ELEVATOR REPLACEMENT

1251 334TH STREET, WOODWARD, IA 50276

A G

B

ID

S

E T

/1

/2

PROJECT LOCATION MAP

SHEET INDEX

AG001

AG002

AD100

AD200

AD201

AG100

COVER SHEET

SITE LOGISTICS PLAN

DEMO FLOOR PLANS

EXISTING CONDITIONS

EXISTING CONDITIONS

OVERALL FLOOR PLANS

ME000 ELECTRICAL GENERAL NOTES & SYMBOLS

ME101 MECHANICAL-ELECTRICAL PLAN

ENLARGED LOCATION MAP

MAIN ENTRY TO WOODWARD

RESOURCE CENTER

FACILITY MAIN ENTRY

PROJECT ELEVATOR

CONTRACTOR PARKING

(LIMITED TO 4 VEHICLES AT THIS LOCATION)

ADDITIONAL CONTRACTOR PARKING

A101 ENLARGED FLOOR PLANS

ME401 ELECTRICAL ONE-LINE DIAGRAM & SCHEDULES

ARCHITECTURAL

OPN Architects, Inc.

I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly Licensed Architect under the laws of the State of Iowa.

Joe Feldmann, AIA

Signature

Registration expires June 30, 2026 Iowa Reg No. 5219

Pages or sheets covered by this seal: all Architectural Sheets listed in 00 0115 List of Drawing Sheets.

Divisions: all Architectural Sections listed in the specifications document

ELECTRICAL

KCL Engineering responsible charge. I am a duly Licensed Engineer under the laws of the

Erick Heynen, P.E.

Registration expires December 31, 2027 Iowa Reg No. P24706

Pages or sheets covered by this seal: all Electrical Sheets listed in 00 0115 List of Drawing Sheets.

Divisions: all Electrical Sections listed in the specifications document.

MECHANICAL / PLUMBING

KCL Engineering responsible charge. I am a duly Licensed Engineer under the laws of the

Chad D. Bass, P.E.

Registration expires December 31, 2027 Iowa Reg No. 21397

Pages or sheets covered by this seal: all Mechanical & Plumbing

Sheets listed in 00 0115 List of Drawing Sheets.

Divisions: all Mechanical & Plumbing Sections listed in the specifications document.

Chad D. Bass, P.E.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:2

A M

AG002

SITE LOGISTICS PLAN

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

FACILITY MAIN ENTRY

PROJECT ELEVATOR

CONTRACTOR PARKING (LIMITED TO 4 VEHICLES)

S1

LOADING DOCK / PROJECT ENTRY

DUMPSTER STAGING

S1

Revision Description Date

COORDINATE CONNEX STAGING IN THIS

AREA WITH CONSTRUCTION MANAGER

THE LOADING DOCK CAN BE USED FOR

PROJECT DELIVERY USE AS NEEDED DURING

CONSTRUCTION. USE MUST BE COORDINATED

WITH THE FACILITY AND ACCESS FOR FACILITY

PROVIDED AT ALL TIMES.

FACILITY MAIN ENTRY.

COORDINATE EXHAUST AT EXISTING WINDOW,

THIS SIDE.

MAINTAIN ACCESS AND DRIVE FOR USE BY

FACILITY AT ALL TIMES. COORDINATE ANY

DELIVERIES THROUGH CONSTRUCTION

MANAGER.

1 2 3 4 5

1 2 3 4 5

1 2 3 4 5

1 2 3 4 5

1 2 3 4 5

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. ALL PENETRATIONS IN FIRE RATED

FLOORS AND WALLS MUST BE SEALED

WITH APPROPRIATE FIRESTOPPING

SYSTEM.

5. PATCH AND REPAIR EXISTING FLOOR

SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION.

A101

F13

AD100

F13

A101

F1

AD100

F1

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:4

A M

AG100

OVERALL FLOOR PLANS

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

N

1/8" = 1'-0" A1

OVERALL FLOOR PLAN - BASEMENT

N

1/8" = 1'-0" K1

FIRST FLOOR PLAN - OVERALL

Revision Description Date

SEE ELEVATOR SPECIFICATIONS FOR

DEMO ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

(ABOVE)

22, 23

(ABOVE)

11,12

SEE ELEVATOR SPEC FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

DEMO DISCONNECT - SEE ELECTRICAL

PATCH ALL HOLES FROM REMOVED

EQUIPMENT AND PREP ROOM FOR

NEW PAINT ON ALL SURFACES.

EXISTING SHEET METAL ENCLOSURE

TO REMOVED AND REPLACED.

REMOVE TO PROVIDE ACCESS TO

MODIFICATIONS CALLED OUT

ELSEWHERE IN THESE PLANS AND

REPLACE TO MATCH EXISTING

CONFIGURATION TO MAINTAIN

PROPER SEPARATION FROM

ELEVATOR MACHINE ROOM.

EXIST ELEV. CAB DIMS:

W: 3'-4 1/2" (CLEAR)

D: 5'-1" (CLEAR)

CLG: 7'-0"

3'-4"W x 7'-1" BI-PARTING

VERTICAL DOOR.

SEE ELEVATOR SPECIFICATIONS FOR

DEMO ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

1 3

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. ALL PENETRATIONS IN FIRE RATED

FLOORS AND WALLS MUST BE SEALED

WITH APPROPRIATE FIRESTOPPING

SYSTEM.

5. PATCH AND REPAIR EXISTING FLOOR

SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:4

A M

AD100

DEMO FLOOR PLANS

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

N

1/2" = 1'-0" F13

DEMO FLOOR PLAN - BASEMENTN

1/2" = 1'-0" F1

DEMO FLOOR PLAN - FIRST FLOOR

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:2

A M

AD200

EXISTING CONDITIONS

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

IMAGE 3

IMAGE 2

IMAGE 1

IMAGE 4

IMAGE 5

IMAGE 6

IMAGE 7

IMAGE 8

IMAGE 9

IMAGE 10

IMAGE 11

IMAGE 12

EXISTING CEILING STRUCTURE TO

REMAIN - REMOVE ACCESS PANEL AND

DRYWALL COMPLETE. PROVIDE

ADDITIONAL FRAMING AS REQUIRED AT

REMOVED ACCESS PANEL AND PROVIDE

NEW DRYWALL AT ENTIRE CEILING. TAPE /

MUD JOINTS ONLY.

REMOVE AND REPLACE EXISTING

DISCONNECT COMPLETE - SEE

ELECTRICAL.

EXISTING DOOR AND FRAME TO REMAIN.

PROTECT IN PLACE DURING

CONSTRUCTION.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY COMPLETE - SEE ELEVATOR

SPEC FOR SPECIFIC REQUIREMENTS.

EXISTING SHEET METAL ENCLOSURE TO

REMOVED AND REPLACED. REMOVE TO

PROVIDE ACCESS TO MODIFICATIONS

CALLED OUT ELSEWHERE IN THESE

PLANS AND REPLACE TO MATCH

EXISTING CONFIGURATION TO MAINTAIN

PROPER SEPARATION FROM ELEVATOR

MACHINE ROOM.

REMOVE FIRE EXTINGUISHER DURING

CONSTRUCTION AND RE-INSTALL AT END OF

PROJECT. RELOCATE AS REQUIRED TO

COORDINATE WITH NEW ELEVATOR

EQUIPMENT.

REMOVE UNUSED EQUIPMENT AND NON-

ELEVATOR RELATED EQUIPMENT - SEE

ELECTRICAL.

EXISTING WALLS TO BE

CLEANED OF DEBRIS, PATCH

ANY HOLES CREATED BY THIS

PROJECT, REMAINDER TO

REMAIN AS IS - NO PAINT.

Revision Description Date

REPLACE ALL CAULKING AT CEILING

AFTER ALL NEW WORK HAS BEEN

COMPLETED.

EXISTING CEILING STRUCTURE TO

REMAIN - REMOVE ACCESS PANEL AND

DRYWALL COMPLETE. PROVIDE

ADDITIONAL FRAMING AS REQUIRED AT

REMOVED ACCESS PANEL AND PROVIDE

NEW DRYWALL AT ENTIRE CEILING. TAPE /

MUD JOINTS ONLY.

EXISTING DOOR AND FRAME TO REMAIN.

PROTECT IN PLACE DURING CONSTRUCTION.

EXISTING ROOM AND SHAFT ARE NOT FIRE

RATED PER REVIEW OF EXISTING

CONDITIONS. AREA ONLY CONNECTS 2

LEVELS AND NO FIRE RATING PRESENT.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

EXISTING SHEET METAL ENCLOSURE TO

REMOVED AND REPLACED. REMOVE TO

PROVIDE ACCESS TO MODIFICATIONS

CALLED OUT ELSEWHERE IN THESE

PLANS AND REPLACE TO MATCH

EXISTING CONFIGURATION TO MAINTAIN

PROPER SEPARATION FROM ELEVATOR

MACHINE ROOM.

REPLACE ALL CAULKING AT CEILING

AFTER ALL NEW WORK HAS BEEN

COMPLETED.

CLEAN FLOOR AND REPAINT - SEE

ELEVATOR SPECIFICATIONS.

EXISTING DOOR AND FRAME TO REMAIN.

PROTECT IN PLACE DURING

CONSTRUCTION.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

CLEAN FLOOR AND REPAINT - SEE

ELEVATOR SPECIFICATIONS.

REMOVE AND REPLACE LIGHTING - SEE

ELECTRICAL. PATCH ALL HOLES AS

REQUIRED

EXISTING SHEET METAL ENCLOSURE TO

REMOVED AND REPLACED. REMOVE TO

PROVIDE ACCESS TO MODIFICATIONS

CALLED OUT ELSEWHERE IN THESE

PLANS AND REPLACE TO MATCH

EXISTING CONFIGURATION TO MAINTAIN

PROPER SEPARATION FROM ELEVATOR

MACHINE ROOM.

EXISTING WALLS TO BE

CLEANED OF DEBRIS, PATCH

ANY HOLES CREATED BY THIS

PROJECT, REMAINDER TO

REMAIN AS IS - NO PAINT.

CLEAN FLOOR AND REPAINT - SEE

ELEVATOR SPECIFICATIONS.

EXISTING SHEET METAL ENCLOSURE TO

REMOVED AND REPLACED. REMOVE TO

PROVIDE ACCESS TO MODIFICATIONS

CALLED OUT ELSEWHERE IN THESE

PLANS AND REPLACE TO MATCH

EXISTING CONFIGURATION TO MAINTAIN

PROPER SEPARATION FROM ELEVATOR

MACHINE ROOM.

EXISTING WALLS TO BE

CLEANED OF DEBRIS, PATCH

ANY HOLES CREATED BY THIS

PROJECT, REMAINDER TO

REMAIN AS IS - NO PAINT.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

DETECTION REQUIRED AT TOP OF SHAFT -

SEE ELECTRICAL.

NEW SHAFT LIGHTING REQUIRED - SEE

ELECTRICAL.

CLEAN ALL SURFACES WITHIN SHAFT -

SEE ELEVATOR SPEC.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

REMOVE AND PROVIDE NEW ELEVATOR

DOORS - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

EXISTING SUMP AND DISCHARGE TO REMAIN.

PROVIDE NEW SUMP PUMP ON DEDICATED

CIRCUIT WITH WATER AND OIL DETECTION -

SEE MECHANICAL / ELECTRICAL.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

NEW PIT AND SHAFT LIGHTING REQUIRED -

SEE ELECTRICAL.

EXISTING JACK TO REMAIN - SEE ELEVATOR

SPEC FOR REQUIREMENTS.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

EXISTING PIT LADDER CAN REMAIN -

ELEVATOR PROVIDER TO CONFIRM

COMPLIANCE WITH ALL ELEVATOR CODES.

SEE ELEVATOR SPEC FOR SPECIFIC

REQUIREMENTS ON PLATFORM AND CAB

REQUIREMENTS.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

NEW SHAFT LIGHTING REQUIRED - SEE

ELECTRICAL.

EXISTING JACK TO REMAIN - SEE ELEVATOR

SPEC FOR REQUIREMENTS.

REMOVE AND PROVIDE NEW ELEVATOR

DOORS - SEE ELEVATOR SPEC.

EXISTING SILL TO REMAIN, CLEAN AND

POLISH - SEE ELEVATOR SPEC.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

REMOVE AND REPLACE EXISTING ELEVATOR

FINISHES - SEE ELEVATOR SPEC AND

DRAWINGS FOR SPECIFIC REQUIREMENTS.

REMOVE AND PROVIDE NEW ELEVATOR

DOORS - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

FINISHES - SEE ELEVATOR SPEC AND

DRAWINGS FOR SPECIFIC REQUIREMENTS.

EXISTING CEILING CAN REMAIN - REPAINT.

PROVIDE NEW RECESS LIGHTING - SEE

ELEVATOR SPEC.

REMOVE AND PROVIDE NEW ELEVATOR

DOORS - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

FINISHES - SEE ELEVATOR SPEC AND

DRAWINGS FOR SPECIFIC REQUIREMENTS.

EXISTING CEILING CAN REMAIN - REPAINT.

PROVIDE NEW RECESS LIGHTING - SEE

ELEVATOR SPEC.

PROVIDE ALL NEW CONTROLS AND CODE

COMPLIANT SIGNAGE. SEE ELEVATOR SPEC

AND DRAWINGS FOR SPECIFIC

REQUIREMENTS.

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:2

A M

AD201

EXISTING CONDITIONS

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

IMAGE 13

IMAGE 14

IMAGE 15

IMAGE 16

IMAGE 17

IMAGE 18

IMAGE 19

IMAGE 20

IMAGE 21

IMAGE 22

IMAGE 23

PATCH ABANDONED HOLE TO MACHINE

ROOM AND PAINT TO MATCH ADJACENT

SURFACES.

COORDINATE ROUTING OF ANY NON-

ELEVATOR WIRING TO AVOID PASSAGE

WITHIN ELEVATOR MACHINE ROOM - SEE

ELECTRICAL.

EXISTING PIPING TO REMAIN. SHOWN FOR

COORDINATION OF EQUIPMENT IN ROOM BELOW.

PIPING TO BE REMEDIATED BY OWNER - NO

WORK. CONFIRM IF PIPING IS REQUIRED.

Revision Description Date

PROVIDE NEW FIXTURES - SURFACE

MOUNTED FIXTURES ARE ACCEPTABLE.

FIXTURES SHOULD COMPLETELY COVER

EXISTING OPENINGS AND MAINTAIN THE

EXISTING FINISHES. INCORPORATE ALL

CODE REQUIRED SIGNAGE INTO

ELEVATOR FIXTURE.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

EXISTING DOOR AND FRAME TO REMAIN.

PROTECT IN PLACE DURING CONSTRUCTION.

EXISTING ROOM AND SHAFT ARE NOT FIRE

RATED PER REVIEW OF EXISTING

CONDITIONS. AREA ONLY CONNECTS 2

LEVELS AND NO FIRE RATED PRESENT.

PROVIDE CODE REQUIRED SIGNAGE AT

ELEVATOR MACHINE ROOM.

PROVIDE NEW FIXTURES - SURFACE

MOUNTED FIXTURES ARE ACCEPTABLE.

FIXTURES SHOULD COMPLETELY COVER

EXISTING OPENINGS AND MAINTAIN THE

EXISTING FINISHES. INCORPORATE ALL

CODE REQUIRED SIGNAGE INTO

ELEVATOR FIXTURE.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

PROVIDE NEW FIXTURES - SURFACE

MOUNTED FIXTURES ARE ACCEPTABLE.

FIXTURES SHOULD COMPLETELY COVER

EXISTING OPENINGS AND MAINTAIN THE

EXISTING FINISHES. INCORPORATE ALL

CODE REQUIRED SIGNAGE INTO

ELEVATOR FIXTURE.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

PROVIDE NEW FIXTURES - SURFACE

MOUNTED FIXTURES ARE ACCEPTABLE.

FIXTURES SHOULD COMPLETELY COVER

EXISTING OPENINGS AND MAINTAIN THE

EXISTING FINISHES. INCORPORATE ALL

CODE REQUIRED SIGNAGE INTO

ELEVATOR FIXTURE.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

IF ANY ELEVATOR FIXTURES ARE NOT TO

BE REUSED, THEN CAULK AND PROVIDE

BLANK PLATE COVER.

CAULK AND SEAL ABANDONED CONDUITS

AT FLOOR ABOVE ELEVATOR MACHINE

ROOM TO PREVENT WATER INTRUSION

TO ROOM BELOW.

PROVIDE NEW FIXTURES - SURFACE

MOUNTED FIXTURES ARE ACCEPTABLE.

FIXTURES SHOULD COMPLETELY COVER

EXISTING OPENINGS AND MAINTAIN THE

EXISTING FINISHES. INCORPORATE ALL

CODE REQUIRED SIGNAGE INTO

ELEVATOR FIXTURE.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING BELL SYSTEM TO REMAIN.

PROTECT IN PLACE.

EXISTING OWNER SIGNAGE TO REMAIN.

REMOVE ALL MISC. LOOSE ITEMS AT

CEILING SPACE.

PATCH ABANDONED HOLE TO MACHINE

ROOM AND PAINT TO MATCH ADJACENT

SURFACES.

EXISTING PIPING / DUCTWORK TO REMAIN.

SHOWN FOR COORDINATION OF EQUIPMENT

IN ROOM BELOW.

PIPING TO BE REMEDIATED BY OWNER - NO

WORK. CONFIRM IF PIPING IS REQUIRED.

EXISTING CEILING STRUCTURE TO REMAIN -

REMOVE ACCESS PANEL AND DRYWALL

COMPLETE. PROVIDE ADDITIONAL FRAMING

AS REQUIRED AT REMOVED ACCESS PANEL

AND PROVIDE NEW DRYWALL AT ENTIRE

CEILING. TAPE / MUD JOINTS ONLY.

IF ANY ELEVATOR FIXTURES ARE NOT TO

BE REUSED, THEN CAULK AND PROVIDE

BLANK PLATE COVER.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL

SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION.

PROVIDE TEMPORARY ENCLOSURES AS

REQUIRED DURING CONSTRUCTION TO

PROTECT WORK AND HOISTWAYS.

PROVIDE TEMPORARY WOOD SHEATHING

PARTITION WALL WITH DOOR. ENCLOSURES

TO BE COORDINATED WITH FACILITY AND

LIMITED TO ONLY WHEN WORK OCCURRING

THIS SIDE. COORDINATE TIMING WITH

FACILITY AND CONSTRUCTION MANAGER.

PREP CLEAN, PATCH / FILL AND DAMAGE TO

FRAME AND REPAINT.

CLEAN AND POLISH ALL SILLS TO

REMAIN - TYPICAL.

PROVIDE NEW ELEVATOR FINISHES -

SEE ELEVATIONS.

EXISTING SHEET METAL ENCLOSURE TO

REMOVED AND REPLACED. REMOVE TO

PROVIDE ACCESS TO MODIFICATIONS CALLED

OUT ELSEWHERE IN THESE PLANS AND

REPLACE TO MATCH EXISTING CONFIGURATION

TO MAINTAIN PROPER SEPARATION FROM

ELEVATOR MACHINE ROOM.

NEW ELEVATOR CONTROLLER - COORDINATE

FINAL LOCATION WITHIN ROOM WITH ALL

OTHER EQUIPMENT - SEE ELEVATOR

SPECIFICATIONS.

NEW ELEVATOR HYDRAULIC TANK -

COORDINATE FINAL LOCATION WITHIN ROOM

WITH ALL OTHER EQUIPMENT - SEE ELEVATOR

SPECIFICATIONS.

NEW ELECTRICAL DISCONNECT - SEE

ELECTRICAL. PROVIDE NEW UNISTRUT

SUPPORT FROM COLUMN TO WALL TO

PROVIDE MOUNTING SURFACE. COORDINATE

FINAL LOCATION WITH ELEVATOR EQUIPMENT.

APPROXIMATE ROUTING OF NEW

ELEVATOR MACHINE ROOM

VENTILATION - SEE MECHANICAL.

PROVIDE OPENINGS AS REQUIRED

AND FULLY SEAL AROUND ALL

PENETRATIONS TO BE WATER TIGHT.

NEW ROUTING OF SUMP DISCHARGE

RUNS TO WEST AND OUT BUILDING -

SEE MECHANICAL. PROVIDE

OPENINGS AS REQUIRED AND FULLY

SEAL AROUND ALL PENETRATIONS TO

BE WATER TIGHT.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL

SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION.

PROVIDE TEMPORARY ENCLOSURES AS

REQUIRED DURING CONSTRUCTION TO

PROTECT WORK AND HOISTWAYS.

PROVIDE TEMPORARY SIGNAGE OR

BARRICADES AS REQUIRED WHEN WORK IS

BEING PERFORMED IN THIS AREA.

PREP CLEAN, PATCH / FILL AND DAMAGE TO

FRAME AND REPAINT.

CLEAN AND POLISH ALL SILLS TO

REMAIN - TYPICAL.

PROVIDE NEW ELEVATOR FINISHES -

SEE ELEVATIONS.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION.

PROVIDE TEMPORARY ENCLOSURES AS

REQUIRED DURING CONSTRUCTION TO

PROTECT WORK AND HOISTWAYS.

PREP CLEAN, PATCH / FILL AND DAMAGE TO

FRAME AND REPAINT.

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. ALL PENETRATIONS IN FIRE RATED

FLOORS AND WALLS MUST BE SEALED

WITH APPROPRIATE FIRESTOPPING

SYSTEM.

5. PATCH AND REPAIR EXISTING FLOOR

SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION.

WALL PANEL TYPE A - ST. STL. BRUSHED

METAL WITH 5WL TEXTURE. PANEL TO BE

SET TIGHT CAB SHELL TO MAINTAIN

MAXIMUM CLEARANCE IN CAB. INSTALL WITH

COUNTERSUNK STAINLESS STEEL SCREWS.

ANODIZED ST. STL. BUMPER - SET FLAT

TO WALL PANEL (NO STAND OFFS)

PROVIDE VENTS AT BASE OF CAB

SIDE WALLS

EXISTING EXPANDED WIRE

MESH TO REMAIN - PAINT

FLAT WHITE - SEE RCP

FRONT / BACK WALL

RESILIENT FLOORING -

SEE SPECIFICATIONS

ELEVATOR CONTROL PANEL

(ANOD ST.STL.)

RESILIENT FLOORING - SEE SPECIFICATIONS

PREFINISHED EXPANDED MESH

INTERIOR BI-PARTING DOOR.

NEW LINEAR LIGHT FIXTURE

RECESSED INTO THE EXISTING

EXPANDED WIRE MESH CEILING.

EXISTING CAB EXTERIOR

EXISTING EXPANDED WIRE MESH TO

REMAIN - PAINT FLAT WHITE - SEE RCP

1/2" = 1'-0" A1

ELEVATOR ELEVATIONS

1/2" = 1'-0"

A13

ELEVATOR REFLECTED CEILING

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:4

A M

A101

ENLARGED FLOOR PLANS

25832000

BID SET 06/16/2026

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

1251 334TH STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

N

1/2" = 1'-0" F13

ENLARGED FLOOR PLAN - BASEMENTN

1/2" = 1'-0" F1

ENLARGED FLOOR PLAN - FIRST FLOOR

EQUIPMENT IDENTIFICATION TAG. REFER TO EQUIPMENT CONNECTION SCHEDULE

DETAIL DRAWING REFERENCE TAG, SIM-SIMILAR, TYP-TYPICAL, OPP-OPPOSITE

INTERIOR ELEVATION DRAWING REFERENCE TAG

GENERAL SYMBOLS

A101

SIM

A101 1

R e f

KEYNOTE#

XXX

X

SHEET REFERENCE

SECTION CUT REFERENCE TAG, SIM-SIMILAR, TYP-TYPICAL, OPP-OPPOSITE

SHEET REFERENCE

JUNCTION BOX, CEILING OR FLOOR MOUNTED.

JUNCTION BOX, WALL MOUNTED, ELEVATION AS NOTED.

J

J

A101

SIM

1 DRAWINGS REVISION. REFER TO TITLEBLOCK FOR REVISION NAME AND DATE

RECESSED LIGHT FIXTURE, LETTER INDICATES SWITCH LEG (TYPICAL), SHADING

INDICATES EMERGENCY LIGHT (TYPICAL)

SURFACE MOUNTED STRIP FIXTURE

LINEAR PENDANT MOUNTED FIXTURE

INDUSTRIAL STRIP LIGHT FIXTURE

WALL MOUNTED STRIP LIGHT FIXTURE.

EMERGENCY LIGHT FIXTURE, WALL MOUNT, +96" OR AS NOTED

EMERGENCY LIGHT FIXTURE, CEILING MOUNT

EXIT SIGN, WALL MOUNT +96", SHADED AREAS INDICATE NUMBER OF

FACES, ARROWS INDICATE SIGN ARROWS

EXIT SIGN, CEILING MOUNT, SHADED AREAS INDICATE NUMBER OF FACES,

ARROWS INDICATE SIGN ARROWS

SINGLE POLE SWITCH, WALL MOUNT, LETTER INDICATES SWITCH LEG

THREE WAY SWITCH, WALL MOUNT, LETTER INDICATES SWITCH LEG

LIGHTING SYMBOLS

a a b

ROUND LIGHT FIXTURE - SURFACE MOUNTED

SQUARE LIGHT FIXTURE - SURFACE MOUNTED

PENDANT MOUNTED LIGHT FIXTURE

POWER SYMBOLS

DUPLEX RECEPTACLE, WALL MOUNTED, TAMPER-RESISTANT

DUPLEX GFCI RECEPTACLE, TAMPER-RESISTANT, WALL MOUNT,

"G" INDICATES PROTECTION INCLUDED IN DEVICE. SHADING INDICATES DEVICE

PROTECTED BY EITHER UPSTREAM GFCI DEVICE OR CIRCUIT BREAKER

EQUIPMENT CONNECTION,

REFER TO EQUIPMENT CONNECTION SCHEDULE FOR CONNECTION TYPE.

REFER TO PANEL SCHEDULES FOR GFCI PROTECTION WHERE REQUIRED

EQUIPMENT CONNECTION, WALL MOUNT,

REFER TO EQUIPMENT CONNECTION SCHEDULE FOR CONNECTION TYPE.

REFER TO PANEL SCHEDULES FOR GFCI PROTECTION WHERE REQUIRED

DUPLEX RECEPTACLE, CEILING MOUNTED

SINGLE RECEPTACLE, WALL MOUNTED

G

SR

DUPLEX RECEPTACLE, WALL MOUNTED, SURFACE RACEWAY

SAFETY DISCONNECT SWITCH

PANELBOARD - SURFACE MOUNTED

PANELBOARD - RECESSED IN WALL

DISTRIBUTION PANELBOARD/SWITCHBOARD - SURFACE MOUNTED AS NOTED.

MOTOR CONNECTION,

REFER TO EQUIPMENT CONNECTION SCHEDULE FOR CONNECTION TYPE.

REFER TO PANEL SCHEDULES FOR GFCI PROTECTION WHERE REQUIRED

M

DUPLEX RECEPTACLE, HALF SWITCHED, WALL MOUNTED, TAMPER-RESISTANT

LOWERCASE LETTER INDICATES SWITCH LEG.

a

ELECTRICAL ABBREVIATIONS

A DEVICE MOUNTED +8" ABOVE

COUNTER TOP (VERIFY LOCATION)

AFF ABOVE FINISHED FLOOR

ATS AUTOMATIC TRANSFER SWITCH

C CEILING

CB CIRCUIT BREAKER

CT CURRENT TRANSFORMER

E EXISTING ITEM TO REMAIN

EC ELECTRICAL CONTRACTOR

EM EMERGENCY LIGHT FIXTURE

ER NEW LOCATION OF EXISTING ITEM

F ROUGH IN FOR FUTURE DEVICE

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FSD FIRE SMOKE DAMPER

G GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

KVA KILO-VOLT-AMPERES

KW KILOWATTS

MC MECHANICAL CONTRACTOR

MCB MAIN CIRCUIT BREAKER

MDP MAIN DISTRIBUTION PANEL

MLO MAIN LUGS ONLY

N NEW DEVICE IN EXISTING LOCATION

NIC NOT IN CONTRACT

NM NONMETALLIC

NTS NOT TO SCALE

OC ON CENTER

OFCI OWNER FURNISHED

CONTRACTOR INSTALLED

OFOI OWNER FURNISHED,

OWNER INSTALLED

R EXISTING ITEM TO BE REMOVED

RR EXISTING ITEM TO BE REMOVED AND

RELOCATED

RN EXISTING ITEM TO BE REMOVED AND

REPLACED WITH NEW

SCCR SHORT CIRCUIT CURRENT RATING

T TAMPER PROOF DEVICE

TCC TEMPERATURE CONTROL CONTRACTOR

TV TELEVISION

TYP TYPICAL

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLTS

VA VOLT-AMPERES

WG WIREGUARD COVER

WP WEATHERPROOF DEVICE

WR WEATHER RESISTANT DEVICE

XFR TRANSFORMER

+24" INDICATES MOUNTING HEIGHT CENTER

LINE OF DEVICE TO FINISHED FLOOR

1. PROVIDE ELECTRICAL INSTALLATION IN ACCORDANCE WITH ALL STATE CODES.

2. THE CURRENT ADOPTED EDITION OF THE ELECTRICAL CODE IS THE STANDARD FOR THE

ELECTRICAL INSTALLATION. VERIFY WITH LOCAL OFFICIALS WHEN PERMITS ARE OBTAINED.

NOTIFY DESIGN TEAM OF ANY DISCREPANCIES BETWEEN THE PROJECT MANUAL OR

DRAWINGS AND THE GOVERNING CODE.

3. INSTALLATION SHALL FOLLOW REQUIREMENTS OF THE ADAAG –AMERICANS WITH

DISABILITIES ACT.

4. REFER TO PROJECT MANUAL AND PROJECT CODE REVIEW SHEET FOR LIST OF APPLICABLE

CODES.

5. PER NEC EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO

ITS CLEAR, EVIDENT AND SPECIFIC PURPOSE OR USE. CONTRACTOR TO PROVIDE FINAL

CIRCUIT IDENTIFICATION FOR ALL NEW AND MODIFIED CIRCUITS AT PROJECT COMPLETION.

CODE NOTES - ELECTRICAL

1. PROVIDE NORMAL WIRING DEVICES AS GRAY UNLESS OTHERWISE NOTED.

2. PROVIDE DEVICES COVER PLATES AS STAINLESS STEEL. MATCH WIRING DEVICES COLOR.

3. PROVIDE GFCI TYPE RECEPTACLES AT ALL LOCATIONS REQUIRED BY THE NEC.

4. INSTALL WALL MOUNTED RECEPTACLES AT +18" ABOVE FINISHED FLOOR UNLESS OTHERWISE

NOTED.

5. INSTALL WALL MOUNTED LIGHT SWITCHES AT +46” ABOVE FINISHED FLOOR UNLESS

OTHERWISE NOTED. EXCEPTION; INSTALL DEVICES ABOVE AN OBSTRUCTED HIGH FORWARD

REACH OBSTACLE GREATER THEN 20 INCHES IN DEPTH AT +42”.

6. INSTALL ABOVE COUNTERTOP RECEPTACLES +8” ABOVE COUNTERTOP OR AS OTHERWISE

INDICATED.

7. AT A COMMON COUNTERTOP, INSTALL ALL RECEPTACLES AND SWITCHES AT THE SAME

HEIGHT UNLESS OTHERWISE SPECIFICALLY INDICATED.

DEVICE INSTALLATION AND MATERIALS - ELECTRICAL

1. COORDINATE LOCATION/INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WITH ALL

OTHER TRADES. BEGIN INSTALLATION AND ROUGH-IN ONLY AFTER PROPER AND TIMELY

COORDINATION WITH ALL TRADES ASSOCIATED WITH THE INSTALLATION IS COMPLETE.

COORDINATE WITH BUILDING STRUCTURE, ARCHITECTURE, MECHANICAL SHEET METAL, ALL

PIPING SYSTEMS, LIGHT FIXTURES, CONDUITS, CABLE TRAYS, EQUIPMENT

ACCESS/CLEARANCE, ETC. REFER TO ALL GENERAL, MECHANICAL, AND ELECTRICAL

DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR

REWORK OF INSTALLED EQUIPMENT RESULTING FROM INSUFFICIENT COORDINATION.

2. ELECTRICAL DRAWINGS ARE ONLY A PORTION OF THE COMPLETE SET OF PLANS AND

CONTRACT DOCUMENTS. THE ELECTRICAL SCOPE OF WORK IS DEFINED BY THE COMPLETE

SET OF CONTRACT DOCUMENTS. THIS INCLUDES BUT IS NOT LIMITED TO REFERENCING;

ARCHITECTURAL PLANS FOR DIMENSIONS AND DETAILS; EQUIPMENT PLANS FOR ROUGH-IN

REQUIREMENTS, MECHANICAL PLANS FOR EQUIPMENT SIZES AND LOCATIONS.

GENERAL NOTES - ELECTRICAL

1. INCREASE CONDUCTOR SIZES ON 20A 120V-1 PHASE CIRCUITS EXCEEDING 100 FEET TO

CENTER OF LOAD TO ACCOUNT FOR VOLTAGE DROP.

2. RACEWAYS AND BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND INDICATE GENERAL

AND APPROXIMATE LOCATIONS. LAYOUTS DO NOT ALWAYS SHOW THE TOTAL NUMBER

OF RACEWAYS OR BOXES FOR THE CIRCUITS REQUIRED, NOR ARE THE LOCATIONS OF

INDICATED RUNS INTENDED TO SHOW THE ACTUAL ROUTING OF THE RACEWAYS.

3. LIGHT FIXTURES, SWITCHES, DEVICES, ETC. ARE SHOWN IN PREFERRED LOCATION.

MODIFY CONDUIT, HANGERS, CIRCUITING, ETC. TO PROVIDE A COMPLETE AND

OPERATIONAL SYSTEM.

4. PROVIDE A DEDICATED GREEN INSULATED GROUND CONDUCTOR TO ALL DEVICES. DO

NOT USE CONDUIT SYSTEM AS THE ONLY EQUIPMENT GROUNDING METHOD.

5. DO NOT INSTALL BOXES BACK-TO-BACK ON OPPOSITE SIDES OF THE SAME WALL.

MAINTAIN MINIMUM OF 8” DISTANCE BETWEEN BOXES WHEREVER APPLICABLE.

6. BALANCE PANEL LOADS DURING INSTALLATION. CIRCUIT NUMBERING SHOWN ON PLANS

MAY BE ADJUSTED TO ACCOMMODATE.

7. PROVIDE TYPED PANEL DIRECTORY AT PROJECT COMPLETION FOR NEW PANELS AND

EXISTING PANELS WITH CIRCUITS MODIFIED DURING PROJECT. USE OWNER’S CURRENT

ROOM NUMBERS AND EQUIPMENT NAMES. PROVIDE UNIQUE CIRCUIT IDENTIFICATION

PER NEC 408.4(A)

8. CONTRACTOR IS RESPONSIBLE FOR OPENINGS IN WALLS, FLOORS, CEILINGS, AND

ROOFS THAT ARE REQUIRED TO COMPLETE THEIR SCOPE OF WORK. SEAL

PENETRATIONS IN ACCORDANCE WITH THE RATING OF THE AFFECTED ASSEMBLY.

REFER TO ARCHITECTURAL CODE PLAN FOR RATED WALLS, FLOORS, AND CEILINGS.

INSTALLATION NOTES - ELECTRICAL

SECURITY - ACCESS CONTROL:

SECURITY MANAGEMENT SYSTEM - HEAD END COMPONENTS

SECURITY MANAGEMENT SYSTEM - FIELD DEVICES

SECURITY MANAGEMENT SYSTEM - ELECTRIFIED DOOR HARDWARE

ROUGH-IN, PATHWAYS AND SLEEVES

ROUGH-IN, PATHWAYS AND SLEEVES

SECURITY - VIDEO SURVEILLANCE:

CAMERA(S)

HEAD END EQUIPMENT AND COMPONENTS

SECURITY MANAGEMENT SYSTEM - ALL CABLING

OFOI

OFCI

CFCI

OWNER FURNISHED & OWNER INSTALLED

OWNER FURNISHED & CONTRACTOR INSTALLED

CONTRACTOR FURNISHED & CONTRACTOR INSTALLED

GENERAL NOTE:

A. MATRIX IS NOT INTENDED TO BE EXHAUSTIVE TO COVER ALL MATERIALS NECESSARY FOR

SCOPE AND SHOULD ONLY BE USED TO QUICKLY IDENTIFY SYSTEMS AND RELATED

INFRASTRUCTURE INSIDE AND OUTSIDE THE BID OF THIS PROJECT. ANY ITEMS FURNISHED OR

INSTALLED BY THE BIDDING CONTRACTOR SHALL COVER ALL REQUIRED APPERTUNANCES

NECESSARY FOR A COMPLETE SYSTEM. THIS SHALL INCLUDE BUT NOT BE LIMITED TO,

EQUIPMENT, ACCESSORIES, TERMINATIONS, TERMINATION COMPONENTS, ALL FINAL

CORDAGE CONNECTIVITY, SOFTWARE, PROGRAMMING, AND THE LABOR TO INSTALL.

SAFETY - FIRE DETECTION AND ALARM:

ROUGH-IN, PATHWAYS AND SLEEVES

INITIATING FIELD DEVICES (SMOKE, MANUAL PULL, MONITOR MODULES)

NOTIFICATION APPLIANCES (HORNS, STROBES, SPEAKERS)

MISCELLANEOUS DEVICES (RELAYS, TEST STATION, ANNUNCIATOR)

N/A N/A N/A

N/A N/A N/A

N/A N/A N/A

OFOI OFCI CFCI

TECHNOLOGY RESPONSIBILITY MATRIX

PROVISION RESPONSIBILITIES DEFINED

RACKS, FRAMES AND ENCLOSURES

COPPER HORIZONTAL CABLING

DATA COMMUNICATIONS SWITCHES AND HUBS

ROUGH-IN, PATHWAYS AND SLEEVES

COMMUNICATIONS - TELECOM SYSTEMS:

REUSE EXISTING

REUSE EXISTING

1. MECHANICAL DEMOLITION DRAWINGS SHOWING EXISTING CONDITIONS HAVE BEEN

PREPARED BASED ON NON-DESTRUCTIVE FIELD OBSERVATION AND AS-BUILT DRAWINGS

PROVIDED BY THE OWNER. FIELD VERIFY EXISTING SYSTEMS BEFORE BEGINNING WORK.

NOTIFY ARCHITECT/ENGINEER IF EXISTING CONDITIONS ARE MATERIALLY DIFFERENT THAN

THOSE SHOWN ON THE PLANS.

2. BE FAMILIAR WITH EXISTING MECHANICAL SYSTEMS THAT WILL BE AFFECTED BY THE

DEMOLITION WORK. OBTAIN PERMISSION FROM THE OWNER'S REPRESENTATIVE TO SHUT

OFF SERVICES OR SYSTEMS THAT AFFECT AREAS BEYOND THE LIMITS OF THE IMMEDIATE

DEMOLITION AREA. INFORM THE OWNER’S REPRESENTATIVE OF THE REASON FOR AND

DURATION OF THE SHUTDOWN. MINIMIZE IMPACT TO OTHER AREAS. PROCEED WITH THE

SHUT-DOWN AFTER PERMISSION FROM THE OWNER IS GRANTED.

3. REMOVE PIPING, HANGERS, DUCTWORK, GRILLES, REGISTERS, DIFFUSERS, ETC. THAT ARE

INDICATED TO BE REMOVED IN A TIMELY MANNER IN ACCORDANCE WITH THE GENERAL

DEMOLITION SPECIFICATIONS. COORDINATE WITH THE OWNER AND OTHER CONTRACTORS.

MECHANICAL – DEMOLITION NOTES

1. COORDINATE MECHANICAL AND ELECTRICAL WORK WITH ALL OTHER TRADES. BEGIN

INSTALLATION AND ROUGH-IN AFTER COORDINATION WITH ALL TRADES ASSOCIATED WITH

THE INSTALLATION IS COMPLETE. COORDINATE BUILDING STRUCTURE, ARCHITECTURAL

ASSEMBLIES, SHEET METAL, ALL PIPING SYSTEMS, LIGHT FIXTURES, CONDUITS, CABLE

TRAYS, ETC. REFER TO ALL GENERAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND

SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR REWORK

ASSOCIATED WITH FAILURE TO COORDINATE.

2. INCORPORATE MECHANICAL SPECIFICATIONS, DRAWINGS, STATE CODES, AND OWNER

STANDARDS INTO WORK.

3. EACH TRADE IS RESPONSIBLE FOR MAKING PENETRATIONS WHERE REQUIRED IN EXISTING

WALLS, FLOORS, CEILINGS, AND ROOFS. MAKE PENETRATIONS NEAT. PATCH, CONCEAL, OR

CAULK OVERCUT.

4. COVER EXPOSED WALL PENETRATIONS WITH ESCUTCHEONS OR SHEET METAL AS

APPROPRIATE.

5. CAULK ALL CONCEALED AND EXPOSED PIPING AND DUCT WALL PENETRATIONS TO PREVENT

NOISE TRANSFER BETWEEN SPACES.

6. ON COMPLETION OF THE INSTALLATION, COOPERATE WITH THE OWNER TO PROVIDE

TESTING, ADJUSTING, AND BALANCING TO OBTAIN PROPER OPERATION OF ALL EQUIPMENT

AND SYSTEMS. PROVIDE ALL FACILITIES AND EQUIPMENT AND COMPLETE ALL TESTS

REQUIRED FOR ADJUSTMENTS AND BALANCING TO ESTABLISH THE PROPER PERFORMANCE

OF EQUIPMENT.

MECHANICAL - GENERAL NOTES

FIRE DETECTION & ALARM NOTES

1. INSTALL HEAT DETECTORS IN WORK AREAS DURING CONSTRUCTION TO MINIMIZE

FALSE TRIPS. INSTALL PERMANENT DETECTORS IN LOCATIONS SHOWN UPON

CONSTRUCTION COMPLETION.

2. INSTALL MODULES AT ELEVATOR EQUIPMENT TO PROVIDE PRIMARY RECALL,

SECONDARY RECALL, FIRE HAT AND SHUNT TRIP. PROVIDE PROGRAMMING AS

NECESSARY FOR FUNCTION SYSTEM.

3. FIRE ALARM ITEMS AND DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL

LAYOUTS, LOCATIONS, AND QUANTITIES SHALL BE IN ACCORDANCE WITH APPLICABLE

CODES, MANUFACTURER’S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

COORDINATE LOCATIONS WITH LIGHTING AND AIR HANDLING SYSTEMS.

4. ALL FIRE ALARM CIRCUITRY IN EXPOSED CEILING SPACES SHALL BE IN ¾” CONDUIT PER

SPECIFICATIONS. EXPOSED CABLING SHALL NOT BE ACCEPTED.

5. ALL CONCEALED, ACCESSIBLE CEILING TILE LOCATIONS SHALL BE ALLOWED TO HAVE

OPEN AIR CABLING INSTALLED. PROVIDE J-HOOKS, BRIDLE RINGS AND ASSOCIATED

CABLE SUPPORTS TO KEEP INFRASTRUCTURE MANAGED AND OFF OF THE CEILING TILE.

6. ELECTRICAL CONTRACTOR SHALL PROVIDE FIRESTOPPING AT ALL PENETRATIONS PER

SPECIFICATION.

COMMUNICATION NOTES

1. REUSE EXISTING POTS LINE IN THE ELEVATOR EQUIPMENT ROOM FOR THE ELEVATOR

TELEPHONE. REVISE LOCATION AND EXTEND AS NECESSARY FOR NEW EQUIPMENT

LOCATIONS.

2. INSTALL NEW DATA CABLING FROM IDF LOCATIONS SHOWN ON PLANS TO EACH

ELEVATOR EQUIPMENT ROOM FOR NEW 2-WAY COMMUNICATION SYSTEM.

ELEVATOR PIT

BOTTOM FLOOR CEILING

TOP FLOOR

TOP FLOOR CEILING

KEY NOTES:

FUSED, LOCKABLE MAIN DISCONNECT SWITCH AND DEDICATED

CAT6 DATA TERMINATION TO SERVE ELEVATOR MAIN POWER.

PROVIDED WITH NO/NC LOW VOLTAGE CONTACTS.

FUSED, LOCKABLE 120V/1POLE DISCONNECT SWITCH TO SERVE

ELEVATOR AUXILLIARY LIGHTING/VENTILATION,

DEDICATED CIRCUIT 120V DUPLEX GFCI MAINTENANCE

RECEPTACLE WITHIN MACHINE ROOM SPACE ADJACENT TO

DISCONNECTS.

FIRE ALARM SYSTEM HAT FLASH, PRIMARY RECALL, AND

SECONDARY RECALL RELAYS.

S

SMOKE DETECTORS INSTALLED AT TOP OF HOISTWAY.

ELEVATOR HOISTWAY LIGHTING. TYP.

PROVIDE HOISTWAY LIGHTING CONTROLS THREE WAY SWITCHES AT

BOTTOM AND TOP FLOOR HOISTWAY ENTRIES. WHERE MULTIPLE CARS

SHARE A COMMON HOISTWAY, PROVIDE 4 WAY SWITCHES AND PROVIDE

SWITCH AT EACH CARS BOTTOM AND TOP FLOORS. SWITCH SHALL

CONTROLS ALL LIGHTING IN HOISTWAY AND PIT

S

LOBBY, TOP FLOOR

TOP OF HOISTWAY2

HOISTWAY LIGHTING SWITCH

S

ELEVATOR LOBBY SMOKE DECTOR.

<21' FROM CENTERLINE OF ELEVATOR

DOOR. TYP FOR EVERY LOBBY.

ELEVATOR LOBBY SMOKE DECTOR.

<21' FROM CENTERLINE OF ELEVATOR

DOOR. TYP FOR EVERY LOBBY.

LOBBY, BOTTOM FLOOR S

SMOKE DETECTOR WITHIN ELEVATOR

MACHINE ROOM

MACHINE ROOM

HOISTWAY LIGHTING SWITCH

120V DEDICATED CIRCUIT PIT SUMP

PUMP SIMPLEX RECEPTACLE

120V DEDICATED CIRCUIT PIT

MAINTENANCE GFCI DUPLEX RECEPTACLE

BOTTOM FLOOR

TYPICAL ELEVATOR HOISTWAY ELEVATION TYPICAL ELEVATOR MACHINE ROOM

ELEVATOR

MAIN POWER

DISCONNECT

ELEVATOR

CONTROL

PANEL

ELEVATOR MACHINE

ROOM LIGHTING.

DEDICATED CIRCUIT. TYP.

AOM

FIRE ALARM

SYSTEM RELAYS

MACHINE ROOM

LIGHTING SWITCH

ELEVATOR

AUX POWER

DISCONNECT

ELEVATOR CAB

RESCUE ASSISTANCE

SYSTEM DISCONNECT

FUSED, LOCKABLE 120V/1POLE DISCONNECT SWITCH AND

DEDICATED CAT6 DATA TERMINATION TO SERVE ELEVATOR CAB

INTERNAL RESCUE ASSISTANCE SYSTEM.

MAINTENANCE

RECEPTACLE

ELEVATOR HOISTWAY LIGHTING POWERED BY DEDICATED

CIRCUIT. FOR EACH CAR, PROVIDE LIGHT FIXTURE AT TOP OF

HOISTWAY, PIT, AND AT EACH FLOOR. FIXTURES ABOVE PIT

LOCATED TO ILLUMINATE TOP OF CAR AT EACH STOP, TYPICAL 10'

ABOVE EACH LEVEL.

208V/3PH ELEVATOR MAIN

DISCONNECT SWITCH

FUSED/LOCKABLE

NO/NC LV CONTACTS

208V/3PH

LV

ELEVATOR

CONTROLLER

120V/1PH 120V/1PHELEVATOR AUXILARY

DISCONNECT SWITCH

FUSED/LOCKABLE

20A/1P DEDICATED CIRCUIT

DEDICATED CIRCUIT

SHUNT TRIP BREAKER

120V/1PH 120V/1PHELEVATOR INTERNAL

RESCUE ASSISTANCE

DISCONNECT SWITCH

FUSED/LOCKABLE

20A/1P DEDICATED CIRCUIT

LV/CAT6POTS LINE FROM

BUILDING MDF

1LV/CAT6

SHUNT TRIP COIL

LVFIRE ALARM

CONTROL PANEL

LV

LV/CAT6CAT6 FROM

BUILDING MDF

1LV/CAT6

AOM

HAT FLASH, PRIMARY,

SECONDARY RECALL

HOISTWAY LIGHTINGDEDICATED 20A/1P CIRCUIT

PIT GFCI DUPLEXDEDICATED 20A/1P CIRCUIT

MACHINE ROOM GFCI DUPLEXDEDICATED 20A/1P CIRCUIT

PIT SUMP PUMP SIMPLEXDEDICATED 20A/1P CIRCUIT

MACHINE ROOM LIGHTINGDEDICATED 20A/1P CIRCUIT

MACHINE ROOM HVAC20A/1P CIRCUIT

120V/1PH

120V/1PH

120V/1PH

120V/1PH

120V/1PH

120V/1PH

TYPICAL ELEVATOR SYSTEMS WIRING DIAGRAM

FUTURE

MANUAL FIRE ALARM PULL STATION

FIRE DETECTION AND ALARM SYMBOLS

SMOKE DETECTOR

SMOKE DETECTOR WITH 520Hz SOUNDER BASE

DUCT SMOKE DETECTOR

HEAT DETECTOR

COMBINATION HORN WITH STROBE

COMBINATION SPEAKER WITH STROBE

STROBE

ADDRESSABLE INPUT MODULE; FS - SPRINKLER WATER FLOW SWITCH,

TS - TAMPER SWITCH, PIV - POST INDICATOR VALVE

FIRE ALARM CONTROL PANEL + EMERGENCY COMMUNICATIONS PANEL

COMBINATION FIRE/SMOKE DAMPER

SMOKE DAMPER

S

S

AIM

ADDRESSABLE OUTPUT MODULE; SD - FAN SHUT DOWN RELAYAOM

S

SB

H HORN

SD

FSD

S

F

FACP

XX

XX

ROUND DUCT (DIAMETER / SYSTEM)

RECTANGULAR DUCT (WIDTH / HEIGHT / SYSTEM)

FIRE/SMOKE DAMPERFSD

R

FLAT OVAL DUCT (WIDTH / HEIGHT / SYSTEM)

ELEVATION CHANGE (RISE OR DROP)

HIGH EFF. TAKE OFF FITTING w/ VOLUME DAMPER

FLEXIBLE DUCTWORK

SUPPLY (SA), OUTSIDE (OA), VENTILATION (VA) AIR DUCT (UP / DOWN /

SECTION)

DUCT END CAP

DUCT ACCESS DOOR

RETURN (RA) AIR DUCT (UP / DOWN / SECTION)

EXHAUST (EA) AIR DUCT (UP / DOWN / SECTION)

SUPPLY DIFFUSER

LINEAR SLOT DIFFUSER

SUPPLY REGISTER OR GRILLE

SIDE WALL DIFFUSER

EXHAUST REGISTER OR GRILLE

ROUND DIFFUSER

EXTERIOR LOUVER

RETURN REGISTER OR GRILLE

MOTORIZED ACTUATOR

THERMOSTAT

X-#

#x#/CFM

FIXTURE IDENTIFICATION TAG

NECK SIZE / CFM

VAV TERMINAL UNIT

RECT. RND. OVAL

TURNING VANES

H.V.A.C. / DUCTWORK SYMBOLS

10/6 SA

10 Ø SA

10/6 Ø SA

AD

M

T

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

STORY CONSTRUCTION

2810 WAKEFIELD CIRCLE

AMES, IA 50010

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/2

/2

:5

:3

P M

ME000

ELECTRICAL GENERAL

NOTES & SYMBOLS

25832000

100% CD SET 06/16/26

WRC FOOD SERVICE ELEVATOR

REPLACEMENT

STATE OF IOWA - 9504.00

34 CEDAR STREET

WOODWARD, IA 50276

109 SE 13TH STREET

DES MOINES, IA 50319

MECHANICAL SCOPE: INSTALL LOCAL ALARM IN KITCHEN WHEN ELEVATOR

EQUIPMENT ROOM IS ABOVE 90 DEGREES. INSTALL THERMOSTAT AS

SHOWN ON PLANS TIED INTO LOCAL ALARM SYSTEM.

Revision Description Date

NOT TO SCALE

ELEVATOR SYSTEM DETAIL

NOT TO SCALE

2 ELEVATOR SYSTEM DETAIL

S

C

S

S

F

+46"

S F

A C

P F

A C

P F

A C

P

B L

HN

F

S

+46"

+46"

F A

C P

F A

C P

F A

C P

S

C

S

+46"

S

FSD

AOMAOM

T

F S

D

AOM

AOM

POWER GENERAL NOTES

A. COORDINATE LOCATION/INSTALLATION OF MECHANICAL AND ELECTRICAL

WORK WITH ALL OTHER TRADES. NO ASPECT OF A SYSTEM INSTALLATION

OR ITS ROUGH-IN SHALL COMMENCE UNTIL PROPER AND TIMELY

COORDINATION WITH ALL TRADES ASSOCIATED WITH THE INSTALLATION HAS

TRANSPIRED. ITEMS TO BE COORDINATED SHALL INCLUDE BUT NOT BE

LIMITED TO: BUILDING STRUCTURE, SHEET METAL, PIPING SYSTEMS, LIGHT

FIXTURES, CONDUITS, CABLE TRAYS, ETC. REFER TO ALL GENERAL,

MECHANICAL, AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR THIS

PROJECT.

B. COORDINATE ELECTRICAL REQUIREMENTS FOR MECHANICAL UNITS WITH

MECHANICAL CONTRACTOR AND FINAL MECHANICAL SHOP DRAWINGS.

C. PROVIDE PENETRATIONS REQUIRED FOR ROUTING RACEWAYS THROUGH

THE BUILDING. COORDINATE FIRE RATED WALL PENETRATIONS AND

PROVIDE CONDUIT SLEEVES AND FIRE STOPPING TO MAINTAIN RATING.

COMMUNICATION GENERAL NOTES

A. COORDINATE LOCATION/INSTALLATION OF MECHANICAL AND

ELECTRICAL WORK WITH ALL OTHER TRADES. NO ASPECT OF A

SYSTEM INSTALLATION OR ITS ROUGH-IN SHALL COMMENCE

UNTIL PROPER AND TIMELY COORDINATION WITH ALL TRADES

ASSOCIATED WITH THE INSTALLATION HAS TRANSPIRED. ITEMS

TO BE COORDINATED SHALL INCLUDE BUT NOT BE LIMITED TO:

BUILDING STRUCTURE, SHEET METAL, PIPING SYSTEMS, LIGHT

FIXTURES, CONDUITS, CABLE TRAYS, ETC. REFER TO ALL

GENERAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND

SPECIFICATIONS FOR THIS PROJECT.

B. PROVIDE PENETRATIONS REQUIRED FOR ROUTING CABLING

AND RACEWAYS THROUGH THE BUILDING. COORDINATE FIRE

RATED WALL PENETRATIONS AND PROVIDE CONDUIT SLEEVES

AND FIRE STOPPING TO MAINTAIN RATING.

C. PROVIDE J-HOOKS, BRIDLE RINGS AND OTHER ACCESSORIES

REQUIRED TO SUPPORT ALL TELECOMMUNICATIONS AND

SECURITY MANAGEMENT SYSTEM CABLING.

A. COORDINATE LOCATION/INSTALLATION OF MECHANICAL AND

ELECTRICAL WORK WITH ALL OTHER TRADES. NO ASPECT OF A

SYSTEM INSTALLATION OR ITS ROUGH-IN SHALL COMMENCE

UNTIL PROPER AND TIMELY COORDINATION WITH ALL TRADES

ASSOCIATED WITH THE INSTALLATION HAS TRANSPIRED. ITEMS

TO BE COORDINATED SHALL INCLUDE BUT NOT BE LIMITED TO:

BUILDING STRUCTURE, SHEET METAL, ALL PIPING SYSTEMS,

LIGHT FIXTURES, CONDUITS, CABLE TRAYS, ETC. REFER TO ALL

GENERAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND

SPECIFICATIONS FOR THIS PROJECT

B. UNLESS NOTED OTHERWISE, CONNECT ALL EMERGENCY

BATTERY FIXTURES WITH AN UN-SWITCHED LEG OF THE

LIGHTING CIRCUIT THAT SERVES THE FIXTURES SPACE.

MAINTAIN NORMAL SWITCHING SCHEME OF EMERGENCY

FIXTURES UNDER NORMAL OPERATION.

C. LIGHTING CONTROLS SENSORS SHOWN ON PLANS AT

SUGGESTED LOCATIONS. VERIFY FINAL LOCATIONS AND

QUANTITIES WITH MANUFACTURER GUIDELINES AND

INSTALLATION RECOMMENDATIONS. COORDINATE

RELOCATIONS WITH ARCHITECTS CEILING PLAN.

LIGHTING GENERAL NOTES

N

E

E

INSTALL ABOVE TOP OF ELEVATOR

RAIL ON WALL.

F1

E

6-26-2

F1

6-26-2

INSTALL NEW NOTIFICATION

HORN AT 7' AFF ON WALL FOR

SUMP PUMP ALERT.

+2'

+9'

F1 F1

E E E E

N

INSTALL NEW 400A

MAIN BREAKER IN

MDP. EXISTING PANEL

IS SQUARE D I-LINE

NEW PANEL 6.

400A PANEL FOR ELEVATOR

CIRCUITS.

NEW OVERHEAD FEEDER

TO PANEL 6

CORE THROUGH WALL AND INSTALL

FIRESTOPPING TO MEET 2 HOUR WALL

REQUIREMENTS

APPROXIMATE BRANCH CIRCUIT

CONDUIT PATH FROM PANEL 6 TO

ELEVATOR EQUIPMENT. COORDINATE

EXACT LOCATION IN THE FIELD

x E

A

WALL CAP BY FAN MFR.

LOCATE 12" ABOVE

GRADE

CORE DRILL/CUT EXISTING

CONCRETE WALL AS REQUIRED

ME101

INSTALL LOCAL ALARM

IN KITCHEN SPACE TO ALERT

STAFF WHEN TEMPERATURE IN

ELEVATOR MACHINE ROOM

IS ABOVE 90 DEGREES

INSTALL ELBOWS AND ACCESSORIES AS NECESSARY

TO INSTALL DUCT AS HIGH AS POSSIBLE IN STORAGE

SPACE.

2" PUMPED DISCHARGE.

INSTALL AS HIGH AS POSSIBLE

IN SPACE

DISCONNECT ELBOW AND PATCH AND

SEAL EXISTING SANITARY PIPING. EXTEND

EXISTING PUMPED DISCHARGE TO ABOVE

CEILING IN ELEVATOR EQUIPMENT ROOM.

DISCHARGE ABOVE

GRADE. INSTALL

ADJACENT TO GAS

ENTRANCE IN

GREEN SPACE.

6-19

6-17

6-26-2

EXISTING BELL TO

REMAIN INTACT

REMOVE EXISTING LIGHTING CIRCUIT FOR CORRIDOR

FROM ELEVATOR SHAFT. NEW LIGHTING FOR SHAFT WILL

BE ON A DEDICATED CIRCUIT.

EXISTING SUMP PIT AND

PIPING TO REMAIN.

REPLACE EXISTING SUMP

PUMP WITH NEW 1/2 HP

SUBMERSIBLE PUMP AND

ALERT SYSTEM.

RN

REPLACE WITH HEAT

DETECTOR DURING

CONSTRUCTION

RN

R

RN

E

EXISTING SIEMENS

DESIGO FIRE ALARM

PANEL

EXISTING DATA RACK.

REUSE FOR NEW 2-WAY

COMMUNICATION DEVICE

E E

E

EXISTING 3 PANELS

TO REMAIN INTACT.

DIETARY MDP

1200A MAIN

REMOVE EXISTING JUNCTION BOX IN SPACE.

EXTEND…

This is the start of the file's text. The full file is on GovTribe.