The document is a set of architectural drawings for the IMHI Plant Operations Building Window Replacement project, issued by the Iowa Department of Administrative Services (DAS) and prepared by Horizon Architecture. The project involves replacing windows at the Plant Operations Building located at 2277 Iowa Avenue in Independence, Iowa. The scope includes removing and replacing 11 existing windows with new thermally broken aluminum replacement windows, with 5 fixed windows (W01) and 6 operable casement windows (W02). The project requires careful coordination with the owner's hazardous materials contractor, as hazardous materials are known to be present on-site and will be removed separately.
The contract is issued as Request for Proposal (RFP) 936900-01, with the construction management being handled by Samuels Group. The project is classified as a repair and replacement of damaged materials, following the 2015 International Existing Building Code (IEBC) and International Plumbing Code (IPC). The drawings provide detailed specifications for window removal, temporary infill, repointing of brick veneer, and installation of new windows, with specific instructions for maintaining the building's existing architectural characteristics. The project appears to be funded by the state of Iowa, with the work focused on maintaining the building's components in sound condition and ensuring no reduction in the building's existing conformance requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFB936900-01 - Bid Form.pdf | ||
| RFB936900-01 - Project Manual.pdf | ||
| 1240944-event.pdf | ||
| RFB936900-01 - Addendum 1.pdf | ||
| RFB936900-01 - Notice.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
PROJECT NO:
DRAWN BY:
COPYRIGHT
DATE:
SHEET TITLE
C-101
COVER SHEET
#Pln
MSN
6/4/2024
I ow a A ve nu e
In de pe nd en ce
IA
C
U se rs \m ik en
\H or iz on
A rc hi te ct ur e\ H or iz on A rc hi te ct ur e
D oc um en ts
\P ro je ct s\ G en er al P ro je ct s\
G
-0
D A S I
M H
I Pl an t
O ps
W in do w s\
M od el a nd
D es ig n\
IM
H
I Pl an t
O ps
W in do w sB K U
P.
pl n
.0
I M
H I
P la n t
O p er at io n s B ld g
W in d ow
R ep la ce m en t
IS
SU
ED
F
O R
B
ID
D
IN
G
COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.
M
IC
H A
EL
H
O R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
PH
3)
-4
W
W W
.H O
R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.
SHEET INDEX
ID
C-101
A-101
A-201
A-301
Name
COVER SHEET
FLOORPLANS
ELEVATION
WALL SECTION & DETAILS
6" TYPICAL, UNLESSOTHERWISE NOTED
OFFICE
1/A-201
D0 1.1
B2
C3
D4
A1
1.01.01
D01.1
S01
W01
GRAPHIC
SYMBOLS INDICATES SECTION
LOCATION ON SHEET
INDICATES SHEET
ON WHICH DRAWING
IS SHOWN
SECTION / DETAIL MARKER DETAIL / ENLARGED PLAN MARKER
INTERIOR ELEVATION MARKER
INDICATES ELEVATION
LOCATION ON SHEET
INDICATES SHEET
ON WHICH DRAWING
IS SHOWN
ELEVATION / SECTION MARKER
INDICATES ELEVATION
LOCATION ON SHEET
INDICATES SHEET
ON WHICH ELEVATION
IS SHOWN
XX
YY
XX
XX
YY
DETAIL / ENLARGED PLAN MARKER
INDICATES DETAIL
LOCATION ON SHEET
INDICATES SHEET
ON WHICH DETAIL
IS SHOWN
SPACE DESIGNATION
WINDOW MARKER
DOOR IDENTIFIERS
SPACE NAME
SPACE NUMBER
WALL TYPE MARKER 4C
SKYLIGHT MARKER
DOOR IDENTIFIER
(ELEVATIONS/SECTIONS)
ENLARGED PLAN REFERENCE
KEYNOTE IDENTIFIER
XX
YY
DOOR
IDENTIFIER
(PLANS)
KEYNOTE; SEE KEYNOTE LEGEND
ON DRAWING'S LAYOUT
ALTERNATE KEYNOTE;
SEE KEYNOTE LEGEND
ON DRAWING'S LAYOUT
(SEE PARTITION LEGEND)
1.01.01
VERIFY SCALE
BAR IS ONE (1) INCH LONG ON
ORIGINAL DRAWING
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
ABBREVIATIONS
A.D. AREA DRAIN
ABV. ABOVE
ADA ACCESSIBLE / AMERICANS
WITH DISABILITIES ACT
ADJ. ADJUSTABLE
A.o.R. AREA OF REFUGE
ALUM. ALUMINUM
ALT. ALTERNATE
A.F.F. ABOVE FINISHED FLOOR
AC. ACOUSTIC / ACOUSTICAL
A.F. ALUMINUM FACE
APPX. APPROXIMATE /
APPROXIMATELY
BD. BOARD
BLK. BLOCK / BLOCKING
BLDG. BUILDING
B.O. BOTTOM OF
B.O.S. BOTTOM OF STEEL
CAB. CABINET
C.C. CENTER-TO-CENTER
CLG. CEILING
CLOS. CLOSET
C.M. CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
C.J. CONTROL JOINT
CONC. CONCRETE
CORR. CORRIDOR
COL. COLUMN
CONT. CONTINUE / CONTINUOUS
CONTR. CONTRACTOR
DIA. DIAMETER
DTL. DETAIL
DN DOWN
DWG. DRAWING
DEPT. DEPARTMENT
DBL. DOUBLE
DIM. DIMENSION
DR. DOOR
EXIST. EXISTING
EQ. EQUAL
E.C. ELECTRICAL CONTRACTOR
EL. ELEVATION
ELEV. ELEVATOR
ELEC. ELECTRIC / ELECTRICAL
EXP. EXPANSION
EXT. EXTERIOR
EA. EACH
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
FIN. FINISH / FINISHED
FLR. FLOOR
F.O. FACE OF
FT. FEET / FOOT
FLUOR. FLUORESCENT
GYP. GYPSUM
GALV. GALVANIZED
GA. GAUGE
G.C. GENERAL CONTRACTOR
HR. HOUR
H.P. HIGH POINT
HVAC HEAT, VENTILATION, AIR-
CONDITIONING
HORIZ. HORIZONTAL
HT. HEIGHT
INSUL. INSULATION / INSULATING
I.D. INSIDE DIAMETER
INCAND. INCANDESCENT
JAN. JANITOR
JT. JOINT
LBS. POUNDS
LAV. LAVATORY
LAM. LAMINATE
L.P. LOW POINT
MAX. MAXIMUM
MFR. MANUFACTURER /
MANUFACTURED
MTL. METAL
MIN. MINIMUM
MIRR. MIRRORED
MTD. MOUNTED
M.O. MASONRY OPENING
MISC. MISCELLANEOUS
MECH. MECHANICAL
N.I.C. NOT IN CONTRACT
NO. NUMBER
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OPP. OPPOSITE
OPG. OPENING
P.C. PLUMBING CONTRACTOR
P.F. PANEL FACE
PR. PAIR
P.T. PRESSURE TREATED
PL. LAM PLASTIC LAMINATE
QTY. QUANTITY
R RISER
R.W.C. RAIN WATER CONDUCTOR
REINF. REINFORCING / REINFORCED
REQ. REQUIRED
R.O. ROUGH OPENING
REV. REVISED / REVISION
REFL. REFLECTED
REC. RECESSED
RAD. RADIUS
S.S. STAINLESS STEEL
ST. STREET
SIM. SIMILAR
STL. STEEL
SQ. SQUARE
SAN. SANITARY
SUSP. SUSPENDED
STD. STANDARD
SPEC. SPECIFICATION
TEL. TELEPHONE
T.O. TOP OF
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TOIL. TOILET
TYP. TYPICAL
THK. THICK
TMP. TEMPERED
T.S.G. TEMPERED SAFETY
GLASS
U.O.N. UNLESS OTHERWISE
NOTED
U.L. UNDERWRITERS
LABORATORIES
VEST. VESTIBULE
V.C.T. VINYL COMPOSITION
TILE
W/ WITH
W.C. WATER CLOSET
WD WOOD
& AND
@ AT
± PLUS OR MINUS
° DEGREE
� ANGLE
[ CHANNEL
# NUMBER
□ SQUARE
Ø ROUND / DIAMETER
� / C.L. CENTER LINE
� / PL. PLATE
∏ U-BAR
∟ LEG-BAR
PLANT
OPERATIONS
BUILDING
9369.00 IMHI Plant Operations
Bldg Window Replacement
RFP 936900-01
BUILDING INFORMATION
PROJECT DIRECTORY
OWNER
IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES (DAS)
109 EAST 13TH STREET
DES MOINES, IA 50319
OWNER'S REPRESENTATIVE: JENNIE ELLIOTT
PHONE: 515.745.3244
EMAIL: jennie.elliott@iowa.gov
CONSTRUCTION MANAGER
SAMUELS GROUP
2929 WESTOWN PARKWAY
SUITE 200
WEST DES MOINES, IA 50266
PROJECT MANAGER: KYLE DAVIS
PHONE: 515.822.6628
EMAIL: kdavis@samuelsgroup.net
ARCHITECT
HORIZON ARCHITECTURE
3116 ALPINE COURT IOWA CITY IA 52245
PHONE: (563) 506-4965
CONTACT: MICHAEL NOLAN, AIA
EMAIL: MICHAEL@HORIZON-ARCHITECTURE.COM
APPLICABLE BUILDING CODE - 2015 IEBC AND IPC
CLASSIFICATION OF WORK - REPAIR
REPLACEMENT OF DAMAGED MATERIALS (WINDOWS) FOR THE
PURPOSE OF MAINTINING COMPONENTS IN SOUND CONDITION
WITH RESPECT TO EXISTING LOADS OR PERFORMANCE
REQUIREMENTS.
CONFORMANCE REQUIREMENT (601.2) - THE WORK SHALL NOT
MAKE THE BUILDING LESS CONFORMING THAT IT WAS BEFORE
THE REPAIR WAS UNDERTAKEN.
K D
AT
E
D
ES
C R
IP
TI
O N
PROJECT NO:
DRAWN BY:
COPYRIGHT
DATE:
SHEET TITLE
A-101
FLOORPLANS
#Pln
MSN
6/4/2024
I ow a A ve nu e
In de pe nd en ce
IA
C
U se rs \m ik en
\H or iz on
A rc hi te ct ur e\ H or iz on A rc hi te ct ur e
D oc um en ts
\P ro je ct s\ G en er al P ro je ct s\
G
-0
D A S I
M H
I Pl an t
O ps
W in do w s\
M od el a nd
D es ig n\
IM
H
I Pl an t
O ps
W in do w sB K U
P.
pl n
.0
I M
H I
P la n t
O p er at io n s B ld g
W in d ow
R ep la ce m en t
IS
SU
ED
F
O R
B
ID
D
IN
G
COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.
M
IC
H A
EL
H
O R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
PH
3)
-4
W
W W
.H O
R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.
A-301
A-301
A-301
REMOVAL WILL BE BY
OWNER DUE TO
PRESENCE OF
HAZARDOUS MATERIALS.
COORDINATE REMOVAL
WITH OWNER'S
HAZARDOUS MATERIALS
CONTRACTOR TO
ENSURE WATER TIGHT
ENCLOSURE IS
MAINTAINED.
CONTRACTOR WILL BE
ON SITE DURING DEMO
TO PROVIDE TEMPORARY
INFILL FOLLOWING
DEMOLITION. PROTECT
EXISTING EXTERIOR
BRICK AND FINISHES TO
REMAIN (TYPICAL 11
WINDOWS)
REMOVE AND DISPOSE OF
WINDOW AIR CONDITIONING UNIT
AND ANY ANCHORS/SUPPORTS
(BY OWNER)
TYP
TYP,
TEMP
INFILL
TYP
OFFICE
A: 189 sq ft
OFFICE
A: 118 sq ft
OFFICE
A: 269 sq ft
OFFICE
A: 359 sq ft
OFFICE
A: 105 sq ft
OFFICE
A: 116 sq ft
RESTROOM
A: 47 sq ft
STORAGE
A: 54 sq ft
ROOM
A: 28 sq ft
W01W01
W01
W01
W02
W02
W02
W01
W02
W02W02
A-301
A-201
A-201
A-201
A-301
REPOINT ENTIRE
DEPTH OF JAMB AND
8" PERIMETER
AROUND WINDOW
OPENING (TYPICAL)
TYP
OFFICE
A: 189 sq ft
OFFICE
A: 118 sq ft
OFFICE
A: 269 sq ft
OFFICE
A: 359 sq ft
OFFICE
A: 105 sq ft
OFFICE
A: 116 sq ft
RESTROOM
A: 47 sq ft
STORAGE
A: 54 sq ft
ROOM
A: 28 sq ft
WINDOW SCHEDULE - ALL DIMENSIONS VERIFY IN FIELD
ID
W01
W02
Quantity
Width (Nominal) 6'-1"
6'-1"
Height (Nominal) 5'-1/2"
5'-1/2"
NOTES
THERMALLY BROKEN FIXED ALUMINUM REPLACEMENT
THERMALLY BROKEN ALUMINUM REPLACEMENT WITH
OPERABLE CASEMENT SECTION
SCALE: 1/4" = 1'-0"1 1st FLOOR DEMO PLAN 0 2' 4' 8' SCALE: 1/4" = 1'-0"2 1st FLOOR
0 2' 4' 8'
GENERAL NOTE:
HAZARDOUS MATERIALS ARE KNOWN TO BE
ONSITE AND WILL BE REMOVED BY OWNER'S
HAZARDOUS MATERIAL CONTRACTOR.
COORDINATE DEMOLITION SCHEDULING AND
SEQUENCE WITH OWNER'S HAZARDOUS
MATERIALS CONTRACTOR.
K D
AT
E
D
ES
C R
IP
TI
O N
PROJECT NO:
DRAWN BY:
COPYRIGHT
DATE:
SHEET TITLE
A-201
ELEVATION
#Pln
MSN
6/4/2024
I ow a A ve nu e
In de pe nd en ce
IA
C
U se rs \m ik en
\H or iz on
A rc hi te ct ur e\ H or iz on A rc hi te ct ur e
D oc um en ts
\P ro je ct s\ G en er al P ro je ct s\
G
-0
D A S I
M H
I Pl an t
O ps
W in do w s\
M od el a nd
D es ig n\
IM
H
I Pl an t
O ps
W in do w sB K U
P.
pl n
.0
I M
H I
P la n t
O p er at io n s B ld g
W in d ow
R ep la ce m en t
IS
SU
ED
F
O R
B
ID
D
IN
G
COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.
M
IC
H A
EL
H
O R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
PH
3)
-4
W
W W
.H O
R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.
THERMALLY BROKEN ALUMINUM
REPLACEMENT WINDOW - MATCH
EXISTING MULLIONS TO THE
EXTENT PRACTICAL. SURFACE
APPLIED MULLIONS OKAY.
REPOINT 8" PERIMETER
AROUND WINDOW
OPENING (TYPICAL)
THERMALLY BROKEN ALUMINUM
REPLACEMENT WINDOW - MATCH
EXISTING MULLIONS TO THE
EXTENT PRACTICAL. SURFACE
APPLIED MULLIONS OKAY.
REPOINT 8" PERIMETER
AROUND WINDOW
OPENING (TYPICAL)
THERMALLY BROKEN ALUMINUM
REPLACEMENT WINDOW - MATCH
EXISTING MULLIONS TO THE
EXTENT PRACTICAL. SURFACE
APPLIED MULLIONS OKAY.
REPOINT 8"
PERIMETER AROUND
WINDOW OPENING
(TYPICAL)
SCALE: 1/4" = 1'-0"1 NORTH ELEVATION
0 2' 4' 8'
SCALE: 1/4" = 1'-0"2 EAST ELEVATION
0 2' 4' 8'
SCALE: 1/4" = 1'-0"3 SOUTH ELEVATION
0 2' 4' 8'
K D
AT
E
D
ES
C R
IP
TI
O N
PROJECT NO:
DRAWN BY:
COPYRIGHT
DATE:
SHEET TITLE
A-301
WALL SECTION
& DETAILS
#Pln
MSN
6/4/2024
I ow a A ve nu e
In de pe nd en ce
IA
C
U se rs \m ik en
\H or iz on
A rc hi te ct ur e\ H or iz on A rc hi te ct ur e
D oc um en ts
\P ro je ct s\ G en er al P ro je ct s\
G
-0
D A S I
M H
I Pl an t
O ps
W in do w s\
M od el a nd
D es ig n\
IM
H
I Pl an t
O ps
W in do w sB K U
P.
pl n
.0
I M
H I
P la n t
O p er at io n s B ld g
W in d ow
R ep la ce m en t
IS
SU
ED
F
O R
B
ID
D
IN
G
COPYRIGHT © 2015 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF OAK TREE HOMES, INC. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF OAK TREE HOMES, INC. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY OAK TREE HOMES, INC.
M
IC
H A
EL
H
O R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
PH
3)
-4
W
W W
.H O
R
IZ
O N
-A R C H
IT
EC
TU
R E.
C O
M
COPYRIGHT © 2018 ALL RIGHTS RESERVED NEITHER ALL NOR ANY PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF Horizon Architecture. THESE PLANS, DESIGNS AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF Horizon Architecture. THIS DOCUMENT IS AN ARTICLE OF SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Horizon Architecture.
4" BRICK VENEER
INFILL DEMOLISHED PLASTER WITH
PVC BLOCKING
SEALANT
NEW THERMALLY
BROKEN REPLACEMENT
WINDOW
100% REPOINT ALL
EXTERIOR JAMBS
INSTALLATION CLIP (BY
MANUFACTURER)
SEALANT
NEW SILL PAN
INSECT SCREEN
DRILLED MASONRY FASTENER
(TAPCON OR SIMILAR), TYPICAL
VIF - AS REQUIRED TO
ACCOMODATE NEW
INSTALLATION CLIP
4" BRICK VENEER
GENERAL CONTRACTOR TO
REMOVE REMAINING EMBEDDED
STEEL WHEN REPOINTING
MORTAR JOINT
BY OWNER'S
HAZMAT
CONTRACTOR
DEMO PLASTER AS REQUIRED TO
ACCESS ANCHOR STRAPS AND
ACCOMMODATE NEW ANCHOR
STRAP INSTALLATION
REMOVE AND DISPOSE OF STEEL FRAME AND GLAZING
4" BRICK VENEER
1/2" OSB OR PLYWOOD
2X4 BLOCKING
TAPCON OR SIMILAR
DRILLED ANCHOR
OPTIONAL 2" XPS
INSULATION (COLD
WEATHER)
4" B
R
IC
K
VE
N
EE
R
INFILL DEMOLISHED PLASTER WITH
PVC BLOCKING
BACKER ROD (IF REQUIRED)
AND SEALANT
BACKER ROD AND
SEALANT AT
VERTICAL JOINT
BACKER ROD AND SEALANT
INSECT SCREEN
DRILLED MASONRY FASTENER
(TAPCON OR SIMILAR), TYPICAL
SCALE: 3" = 1'-0"3 WINDOW DETAIL
0 3'' 6'' 9''SCALE: 3" = 1'-0"1 DEMOLITION SECTION
0 3'' 6'' 9''
SCALE: 3" = 1'-0"2 TEMPORARY INFILL DETAIL
0 3'' 6'' 9''
SCALE: 3" = 1'-0"4 WINDOW JAMB
0 3'' 6'' 9''
| IMHI PLANT OPS WINDOWS ISSUED FOR BIDDING 20240604 |
| 9369.00 IMHI Plant Operations Bldg Window Replacement |
| CD |
| C-101 COVER SHEET |
| A-101 FLOORPLANS |
| A-201 ELEVATION |
| A-301 WALL SECTION & DETAILS |
File details come from the government source that posted it. Updated .