RFB931700-01 Addendum #1 Summary

This is an Addendum #1 document issued by the State of Iowa Department of Administrative Services for the replacement of 25 interlocking doors at the Mount Pleasant Correctional Facility (MPCF) located at 1200 East Washington Street, Mount Pleasant, Iowa. The project encompasses replacement of doors across multiple buildings including the Northcore Building, 10 Cell area, Master Controls, Corridor Doors, Fire Exit Doors, Powerhouse, and Appliance Shop. The base bid includes all material, labor, and equipment associated with the work shown in the contract documents, excluding abatement and demolition of Powerhouse and Appliance Shop doors to be completed by the owner, with a $6,000 allowance for controls coordination and troubleshooting. A pre-bid meeting was held on November 7, 2023 at 11:00 AM at MPCF with both in-person and virtual attendance options. Bids were due November 30, 2023 at 2:00 PM, with bid opening scheduled for November 30, 2023 at 3:00 PM via conference call. The construction phase is scheduled for May 2024 through October 2024, with submittals due between December 2023 and February 2024 and closeout in October 2024. The addendum clarifies work hours as 6:00 AM to 4:00 PM, Monday through Thursday or Tuesday through Friday, with special 6:00 PM to 4:00 AM hours required for two of the three turnkey slider doors.

The construction budget is $777,400. Bid security of 5% of the total bid amount is required, and the apparent low bidder must submit a subcontractor and supplier list within 48 hours of bid opening. All bidders must comply with the modified ConsensusDocs 802 contract template, provide project-specific certificates of insurance and performance and payment bonds prior to contract execution, and register with the IMPACS Electronic Procurement System to submit bids. On-site supervision by the prime contractor is required at all times, and all personnel must pass background checks valid for two years and complete annual PREA training. Questions and substitution requests were due in writing by November 15, 2023 at 12:00 PM. The addendum includes updated drawings (Sheet A-5 Door Schedule and Hardware Sets, and Sheet A-6 General Demolition Notes) and provides site-specific rules prohibiting temporary partitions secured to ceilings due to hazardous materials in the Northcore Building ceiling, requiring one-door-at-a-time replacement sequencing in that building.

View the file

Other files

File Type Posted
RFB931700-01 Project Manual.pdf PDF
RFB931700-01 - Drawings.pdf PDF
RFB931700-01 - Notice to Bidders.pdf PDF
1185325-event.pdf PDF
RFB931700-01 - Bid Form.pdf PDF
RFB931700-01 - Bid Form.pdf PDF
RFB931700-01 - Notice to Bidders.pdf PDF
RFB931700-01 - Drawings.pdf PDF
RFB931700-01 Project Manual.pdf PDF
RFB931700-01 Addendum#1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum 1 for RFB931700-01

Project Name: DOC MPCF Interlocking Doors Replacement

RFB #: 931700-01

DAS Project #: 9317.00

Date: 11/15/2023

Bids Due: November 30, 2023 @ 2 pm

1. See attached Pre-bid Meeting Minutes from the Pre-Bid Walkthrough on November 7, 2023 @

11 am and Attendee List

2. QUESTIONS

A. Question 1: Is there a project bid estimate available?

B. Answer 1: The construction budget is $777,400.

3. SPECIFICATIONS

A. SECTION 00 0107 SEALS PAGE

i. Seals have been signed

B. SECTION 01 1200 CONTRACT SUMMARY

i. Section 1.05 A: Work hours are 6:00 am to 4:00 pm, Monday through Thursday or Tuesday through Friday unless arrangements are made in advance. Work hours for two of the three Turnkey slider doors (S-1, S-2, S-3) will need to be

6:00 pm to 4:00 am.

4. DRAWINGS

A. SHEET A-5 Updated Door Schedule and Hardware Sets

B. SHEET A-6 Added General Demolition Notes

State of Iowa - Department of Administrative Services 109 SE 13th St.

Des Moines, Iowa 50319 P: (515) 281-7260

Project: 9317.00 DOC MPCF Interlocking Door Replacements

1200 East Washington Street Mount Pleasant, Iowa 52641

P: 319-385-9511

RFB Pre-Bid Minutes: Meeting #1

Meeting Date Nov 7, 2023 Meeting Time 11:00 AM - 12:00 PM Central Time (US & Canada)

Meeting Location MPCF/Teams Video Conferencing Link https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTF mLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v 2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b 72-69be-4702-b867-64b92d76e44f%22%7d

Overview Meeting to allow prospective bidders to visit the site, when possible, and learn more about the project.

Notes

Attachments Attendee List.pdf, RFB931700-01 Project Manual.pdf, RFB931700-01 Drawings.pdf

Scheduled Attendees

Name Company Phone Number Email Attendance

Michael Nolan Horizon Architecture michael@horizon-architecture.com Present

Adam Douglas McGough Construction adam.douglas@mcgough.com Present

Leilani Hammel McGough Construction P: (515) 344-8980 leilani.hammel@mcgough.com Present

Jonathan Peters McGough Construction jon.peters@mcgough.com Absent

Jeremy Howk Mount Pleasant Correctional Facility

P: (319) 385-9511 jeremy.howk@iowa.gov Present

Tony Kempker Mount Pleasant Correctional Facility

P: (319) 385-9511 ext.

anthony.kempker@iowa.gov Present

James Trower State of Iowa - Department of Administrative Services james.trower@iowa.gov Absent

Introduction

No. Mtg Origin Title Assignment Due Date Priority Status

1.1 1 Introductions Open

Description DAS - Owner Representative

• James Trower

McGough Construction - Construction Manager

• Adam Douglas, PX/Sr. Project Manager

• Leilani Hammel, Project Engineer

• Jon Peters, Superintendent

MPCF

State of Iowa - Department of Administrative Services Page 1 of 5 Printed On: Nov 10, 2023 08:21 AM CST https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://teams.microsoft.com/l/meetup-join/19%3ameeting_YWU1ZGI0NzUtZGRiYy00OTFmLWJmYTgtNWM2OGMwNDRhMmY1%40thread.v2/0?context=%7b%22Tid%22%3a%22c6c429d4-d18c-4ab8-a9a8-f0c82d33f945%22%2c%22Oid%22%3a%2268b50b72-69be-4702-b867-64b92d76e44f%22%7d https://storage.procore.com/v4/d/us-east-1/pro-core.com/companies/42578/01HEWS6A81HRRSGQ6MFEE4W533?sig=1274cf742ad8883360e670c6b930c09df9adcfc02bb06912c12880aa3b6fd993 https://storage.procore.com/v4/d/us-east-1/pro-core.com/companies/42578/01HEJN5X1BCKSQB96J8WT5TS4T?sig=e68f9150a26e22d285c628e05181867ad385d9857f1f9b7578c13d1eda2db384 https://storage.procore.com/v4/d/us-east-1/pro-core.com/companies/42578/01HEJN5TMBZZ2S4R9V70EXDV5H?sig=28c83760454af72e763ed1ee270549f5a893e28fab9d04fa6be33b6972014f70

• Jeremy Howk

• Tony Kempker

• Kristi Perry

Horizon

• Michael Nolan

Earth Services & Abatement

• Chris Riley

Official Documented Meeting Minutes See attached Attendee List.

Project Overview

2.1 1 Project Description Open

Description Base bid: All material, labor and equipment associated with all work shown on contract documents complete including the plans and specifications, excluding abatement and demolition of the Powerhouse and Appliance Shop doors to be done by owner. Include a $6,000 allowance for controls coordination and troubleshooting

Official Documented Meeting Minutes

• Door replacement will have to happen one door at a time in the Northcore Building.

• Mike Nolan reiterated that there is hazardous material in the ceiling in the Northcore building so no temp partitions should be secured to the ceiling. Both hazardous material reports are included in the project manual, too.

2.2 1 Project Schedule Open

Description

• Contract(s) Issued: 12/4/23

• Submittals: December 2023 - February 2024

• Construction: May 2024 - October 2024

• Closeout: October 2024

A pull-plan session will be held with the successful bid package contractors to finalize the construction schedule.

State Holidays: New Year's Day, Martin Luther King Day, Memorial Day, 4th of July, Labor Day, Veterans Day, day before Thanksgiving, Thanksgiving and day after Thanksgiving, Christmas Day, day after Christmas.

2.3 1 Site Rules Open

Description

• Onsite supervision by Prime Contractor is required at all times when work by that contractor or their subcontractors/suppliers is taking place.

• Contractors shall provide daily logs for each day they are on site.

• Construction progress meeting will be established once construction starts.

• It is of the utmost importance to show respect and courtesy to all staff at all times.

Meeting #1 - RFB Pre-Bid Project: 9317.00 DOC MPCF Interlocking Door Replacements

State of Iowa - Department of Administrative Services Page 2 of 5 Printed On: Nov 10, 2023 08:21 AM CST

• Clean all debris, materials, and bring all finishes back to existing conditions in the area they were working in prior to moving to the next area.

• No smoking, vaping or smokeless tobacco use onsite.

• Temporary facilities by each trade bid packages for their workers.

• Tool control - Contractor shall provide all equipment and tools for Contractor’s own cleanup. Clean up shall be done at end of every shift or more frequently if required for the Contractor to perform their work, for other Contractors to perform their work, as required by the Owner’s operations, and at the discretion of the Construction Manager.

• Cell phones - Cell phones, weapons, and cameras/camcorders are not allowed inside the facility. The foreman will be allowed to have one cell phone.

• Background checks o Must be performed on all on site employees, including sub-contractors.

o The Contractor hereby explicitly authorizes the Iowa DAS to conduct criminal history and/or other background investigation(s) of the Contractor, its officers, supervisory personnel, employees, and other staff retained by the Contractor or their sub-contractors for the performance of the contract.

o A State of Iowa record check request form will be provided at the pre-construction meeting of successful bidder.

o Each contractor who will be working onsite must also take the PREA test which can be found here: https://docs.google.com/presentation/d/1_8IcvvpMCYdqasseVuOxzY2ISqjS3RUi6Oups7t6-zA/pub?start=false&loop=false&delayms=3000&slide=id.p

• Work hours: 6am - 4pm, Monday through Thursday or Tuesday through Friday unless arrangements are made in advance.

• View Specification 01 1200 - Contract Summary for more information.

Official Documented Meeting Minutes

• A job box can be kept in the basement of the Northcore building. The job box will have to have two locks, one form the contractor and one from MPCF. Tony noted that the job box will have to fit through a 3'-0" door.

o Contractors should come prepared with all tools inventoried prior to the first day onsite as this will allow for a quick inventory and can save a couple hours of time.

• Background checks are required for all employees and are good for 2 years, the PREA test will have to be completed yearly.

• Work hours for two of the turnkey slider doors will be 6:00 pm to 4:00 am.

RFB Overview

3.1 1 Bid Submission Open

Description

• Bids are due November 30, 2023 @ 2pm

• The Bid shall be submitted to the Issuing Officer through the IMPACS Electronic Procurement System.

o Link and information is in the project manual o Contractors will need to register prior to bidding o Bidders will need to register regardless of whether it has already done business with the State of Iowa.

o Bidders should complete the registration process and ensure the ability to log in as soon as possible to ensure Bids can be submitted on the due date.

o Please make sure the electronic documents submitted contain any required signatures. Digital signatures will be accepted.

• Bid Opening will be held via conference call on November 30, 2023 @ 3pm

• Contractor shall reference section 00 0116 for the bid submittal checklist o Bid Proposal Information o Non Discrimination Clause Information o Contractor Targeted Small Business Enterprise Pre-Bid Contract Information o Bid Security – 5% of total Bid amount

State of Iowa - Department of Administrative Services Page 3 of 5 Printed On: Nov 10, 2023 08:21 AM CST https://protect-us.mimecast.com/s/AmLdCjRv4AcYNrkJfWlxTi https://protect-us.mimecast.com/s/AmLdCjRv4AcYNrkJfWlxTi

• Apparent low bidder will be required to submit subcontractor/supplier list 48hrs after the bid opening

3.2 1 Bid Schedule Open

Description

• Questions/Substitutions Due in Writing to Construction.Procurement@iowa.gov: November 15, 2023 by 12 pm.

• Addendum Issued:

• Bids Due: November 30, 2023

• Tentative NOI Issued: December 1, 2023

3.3 1 Administrative Details Open

Description

• Contractors will sign a modified ConsensusDocs 802. Example in the project manual.

• Project-specific Certificate of Insurance must be provided prior to contract execution. Follow example in the project manual and limits in the 802.

• Project-specific P&P bonds must be provided prior to contract execution.

• Successful contractor must turn in their list of subcontractors and suppliers within 48 hours of the bid.

• DAS will provide tax exempt certificates upon request.

• Procore will be used for all project management, at no cost to the trade contractor.

o Submittals, Invoicing, RFIs, ASIs, PRs, RFQs o Contracts, Change Orders and Certificates of Substantial and Final Completion will also use Docusign

• Contractor Schedule of Values shall be broken out as specified in the project manual.

o SOV must contain a closeout line item for at least 1% of the total contract value.

o This line item can only be invoiced once the certificate of final completion has been signed by all parties.

3.4 1 Pre-Bid Site Visits Open

Description

• Turnkey

• 10 Cell

• Master Controls

• Corridor Doors

• Fire Exit Doors

• Powerhouse/Appliance Shop

Questions

4.1 1 Questions Open

Description Submit all questions in writing to construction.procurement@iowa.gov.

State of Iowa - Department of Administrative Services Page 4 of 5 Printed On: Nov 10, 2023 08:21 AM CST mailto:Construction.Procurement@iowa.gov:

mailto:construction.procurement@iowa.gov

These meeting minutes are believed to be an accurate reflection of those items discussed and the conclusions that were reached during the referenced meeting.

Please contact State of Iowa - Department of Administrative Services if there are any discrepancies or questions with the content of these minutes.

State of Iowa - Department of Administrative Services Page 5 of 5 Printed On: Nov 10, 2023 08:21 AM CST

PROJECT XXXX.XX SEALS PAGE 00 0107 - 1

SECTION 00 0107

SEALS PAGE

I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge.

Discipline:_____Architecture__________________ Stamp:

Company Name:____Horizon Architecture_______

Address:___3116 Alpine Court_________________

Telephone:___(563) 506-4965__________________

Name:___Michael Nolan, AIA__________________ Responsibility: All Architecture Sheets and Specs

License#:___06926_________________________ ______________________________________

I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge.

Discipline: Electrical & Controls ________________ Stamp:

Company Name: Innovative Engineers, Inc._______

Address: 2871 Heinz Rd Suite B, Iowa City, IA 52240

Telephone: 319-855-4115_____________________

Name: Mohammed Abu-Hasan, PE_____________ Responsibility: Electrical & Controls Sheets

License#: 20081________________________________ _____________________________________

END OF SECTION

9317.00

M

AR

K D

AT

E

D

ES

C R

IP

TI

O N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

A-5

DOOR DETAILS

#Pln

MSN

11/8/2023

E A S T

W A S H

IN

G

TO

N

S

TR

EE

T

M O

U N

T

PL

EA

S A N

T, I

A

C

U se rs \m ik en

\H or iz on

A rc hi te ct ur e\ H or iz on A rc hi te ct ur e

D oc um en ts

\P ro je ct s\ G en er al P ro je ct s\

G

-0

M

PC

F D oo rs

\1

M od el a nd D es ig n\ M

PC

F

D oo rs .p ln

.0

D O

C M

P C

F

IN

TE

R

LO

C

K

IN

G D

O O

R R

EP

LA

C

EM

EN

TS

IS

SU

ED

F

O R

P

ER

M

IT

A N

D C

O N

ST

R

U C

TI

O

N

M

IC

H A

EL

H

O R

IZ

O N

-A R C H

IT

EC

TU

R E.

C O

M

PH

3)

-4

W

W W

.H O

R

IZ

O N

-A R C H

IT

EC

TU

R E.

C O

M

2" AS SCHED 2"

PE

R

S C

H

ED

U

LE

2"

PE

R

S C

H

ED

U

LE

PER SCHEDULE

2" AS SCHED 2"

PE

R

S C

H

ED

U

LE

2"

A-5

A-5

A-5

A-5

A B C

DOOR

FRAMES

DOOR

PANELS

TYP

TYP

4-5 LITES PER

MANUFACTURER

TYP

TYP

DOOR SCHEDULE

ID

CE-1

CE-2

CE-3

CW-1

CW-2

CW-3

FE-13

FE-14

FE-26

S-1

S-2

S-3

S-4

S-5

S-6

T-1

Quantity

W 3'-8"

3'-8"

3'-8"

3'-8"

3'-8"

3'-8"

3'-4"

3'-7 1/2"

3'-4"

3'-10"

3'-10"

3'-10"

3'-4"

3'-4"

3'-5"

3'

HT

7'-2"

7'-2"

7'-2"

7'-2"

7'-2"

7'-2"

7'

6'-11 1/4"

7'

6'-10"

6'-10"

6'-10"

6'-8"

6'-8"

6'-8"

7'

THK

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

2"

1 3/4"

2"

2"

2"

2"

2"

1 3/4"

1 3/4"

-3/4"

FRAME

3 & 4/A-5

3 & 4/A-5

3 & 4/A-5

3 & 4/A-5

3 & 4/A-5

PANEL

B

B

B

B

B

B

C

C

C

A

A

A

B

A

GLZ

12"x12"

12"x12"

12"x12"

12"x12"

12"x12"

12"x12"

MULTI

MULTI

MULTI

6"x12"

GATE

MULTI

HW SET

STENCIL

CORRIDOR E-1

CORRIDOR E-2

CORRIDOR E-3

CORRIDOR W-1

CORRIDOR W-2

CORRIDOR W-3

FIRE EXIT 13

FIRE EXIT 14

FIRE EXIT 26

10 CELL WEST

LOCK TYPE

MOGUL

MOGUL

MOGUL

MOGUL

MOGUL

MOGUL

MOGUL

PARACENTRIC

PARACENTRIC

PARACENTRIC

PARACENTRIC

PARACENTRIC

PARACENTRIC

NOTES

PATCH BROKEN BLOCK AT BASE

RETAIN AND REINSTALL PLACARDS

RETAIN AND REINSTALL PLACARDS

RETAIN AND REINSTALL PLACARDS

RETAIN GATE AND HOUSING, REPLACE

OPERATOR AND GUIDE TRACK. REPAINT ALL

RETAINED ASSEMBLY.

RETAIN AND REINSTALL PLACARDS

3/4" PLYWOOD PANEL WITH (3) BOLTED HINGES

AND 2" HOLE FOR CHAIN/PADLOCK SECUREMENT

EXISTING STEEL

DOOR OPERATOR HOUSING

NEW WELD

HEAD

NOTE:

1. SHIM DOOR DEVICE AS REQUIRED.

2" FIELD STITCH WELD @ 6" O.C. TO

DOOR OPENING EMBED.

2. FASTEN DOOR OPERATOR HOUSING

WITH MASONRY BOLT ANCHORS @ 12"

O.C. BEYOND DOOR R.O.

EXISTING STEEL JAMB

RECEIVER JAMB

EXISTING STEEL JAMB

DOOR BOTTOM GUIDE

LOCK COLUMN

NEW WELD

NEW WELD

NOTE:

1. SHIM DOOR DEVICE AS REQUIRED.

2" FIELD STITCH WELD @ 6" O.C. TO

DOOR OPENING EMBED.

2"

2" 3" 2"

TAMPER RESISTANT SEALANT

2" STEEL HEAD FRAME,

GROUT SOLID

ELECTRICAL CONDUIT (AS REQ)

DRILLED SLEEVE ANCHOR

2"

2" 3" 2"

2"

2" 3" 2"

TAMPER RESISTANT SEALANT

2" STEEL JAMB FRAME,

GROUT SOLID

DRILLED SLEEVE ANCHOR

ELECTRICAL CONDUIT (AS REQUIRED)

TAMPER RESISTANT SEALANT

2" STEEL JAMB FRAME,

GROUT SOLID

DRILLED SLEEVE ANCHOR

ELECTRICAL CONDUIT (AS REQUIRED)

ELECTRIC HINGE (AS REQUIRED)

JAMB

2"

2" 3 1/2" 2"

EXISTING METAL FRAME

INFILL. PATCH RUSTED

AREAS, PRIME AND PREP

FOR PAINT

NEW 2" STEEL HEAD FRAME

ELECTRICAL CONDUIT (AS REQ)

CONTINUOUS WELD CONTINUOUS WELD

2"

2" 3 1/2" 2"

2"

2" 3 1/2" 2"

EXISTING METAL

FRAME INFILL. PATCH

RUSTED AREAS, PRIME

AND PREP FOR PAINT

NEW 2" GALVANIZED

STEEL JAMB FRAME,

PAINTED

EXISTING METAL

FRAME INFILL. PATCH

RUSTED AREAS, PRIME

AND PREP FOR PAINT

CONTINUOUS WELD

NEW 2" GALVANIZED

STEEL JAMB FRAME,

PAINTED

CONTINUOUS WELD

JAMB

HARDWARE SETS

SET 1 - CORRIDOR DOORS

(2) STANDARD HINGES

(1) ELECTRIC HINGE

(1) ELECTRIC RELEASE MORTISE LOCKSET

(MOGUL KEY)

(1) MAG HOLD OPEN (FA CONNECTED)

(1) CLOSER

(1) DOOR POSITION SENSOR

(1) KICK PLATES

SET 2 - EXTERIOR CORRIDOR DOOR

(4) STANDARD HINGES

(1) MAG HOLD CLOSE (FA CONNECTED)

(1) OVERHEAD CLOSER

(1) DOOR POSITION SENSOR (THRU MAG)

(2) KICK PLATES

(2) PULL HANDLES

(1) THRESHOLD

(1) WEATHERSTRIPPING

SET 3 - EXTERIOR CORRIDOR DOOR

(OPENER)

(4) STANDARD HINGES

(1) MAG HOLD CLOSE (FA CONNECTED)

(1) AUTOMATIC OPENER/CLOSER

(1) REMOTE SWITCH

(1) DOOR POSITION SENSOR (THRU MAG)

(2) KICK PLATES

(2) PULL HANDLES

(1) THRESHOLD

(1) WEATHERSTRIPPING

SET 4 - EXTERIOR STAIR DOOR

(4) STANDARD HINGES

(1) PANIC EXIT DEVICE

(1) MORTISE LOCK/LATCH (MOGUL KEY)

(1) EXTERIOR HANDLE

(1) OVERHEAD CLOSER

(1) DOOR POSITION SENSOR

(2) KICK PLATES

(1) THRESHOLD

(1) WEATHERSTRIPPING

SET 5 - SLIDING DOORS

(1) SLIDING DOOR HARDWARE WITH MANUAL

RELEASE (PARACENTRIC KEYING)

SCALE: 1/4" = 1'-0"1 DOOR FRAMES AND PANELS

0 2' 4' 8'

SCALE: 1 1/2"= 1'-0"3 SLIDING DOOR HEAD

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"4 SLIDING DOOR JAMB DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"5 DOOR HEAD DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"6 DOOR JAMB DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"7 EXTERIOR DOOR HEAD DETAIL

0 6'' 12'' 18''

SCALE: 1 1/2"= 1'-0"8 EXTERIOR DOOR JAMB DETAIL

0 6'' 12'' 18''

/7

/2

AD

D

EN

D

U

AR

K D

AT

E

D

ES

C R

IP

TI

O N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

A-6

APPLIANCE

SHOP AND

POWERHOUSE

KEY PLANS

#Pln

MSN

11/8/2023

E A S T

W A S H

IN

G

TO

N

S

TR

EE

T

M O

U N

T

PL

EA

S A N

T, I

A

C

U se rs \m ik en

\H or iz on

A rc hi te ct ur e\ H or iz on A rc hi te ct ur e

D oc um en ts

\P ro je ct s\ G en er al P ro je ct s\

G

-0

M

PC

F D oo rs

\1

M od el a nd D es ig n\ M

PC

F

D oo rs .p ln

.0

D O

C M

P C

F

IN

TE

R

LO

C

K

IN

G D

O O

R R

EP

LA

C

EM

EN

TS

IS

SU

ED

F

O R

P

ER

M

IT

A N

D C

O N

ST

R

U C

TI

O

N

M

IC

H A

EL

H

O R

IZ

O N

-A R C H

IT

EC

TU

R E.

C O

M

PH

3)

-4

W

W W

.H O

R

IZ

O N

-A R C H

IT

EC

TU

R E.

C O

M

SD-02

SD-01

APPLIANCE BARN - MAIN LEVEL

SD-03

APPLIANCE BARN - LOWER LEVEL

PD-03PD-04PD-05

PD-01

PD-07

PD-06

POWERHOUSE - FIRST FLOOR

PD-02

POWERHOUSE - SECOND FLOOR

POWERHOUSE AND APPLIANCE BARN DOOR SCHEDULE

ID

PD-01

PD-02

PD-03

PD-04

PD-05

PD-06

PD-07

SD-01

SD-02

SD-03

Quantity

W 5'

3'

4'

3'

3'

3'

2'-10"

6'

6'

6'

HT

7'

6'-8"

6'-8"

6'-8"

7'

7'

7'

7'

7'

7'

THK

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

1 3/4"

FRAME DEPTH

9.00"

9.00"

9.00"

9.00"

6.00"

8.00"

8.00"

5.50"

5.50"

5.50"

FRAME

1 (*)

PANEL

GLZ

10.75"x10.75"

24"x32"

36"x36"

18"x18"

24"x36"

24"x36"

24"x36"

HW SET

STENCIL

RECYCLE

NOTES

DOUBLE DOOR - VISION PANEL

SINGLE DOOR - HALF LITE

SINGLE DOOR - HALF LITE

SINGLE DOOR

SINGLE DOOR - LARGE VISION PANEL

SINGLE DOOR

SINGLE DOOR

DOUBLE DOOR, HALF LITE

DOUBLE DOOR, HALF LITE

DOUBLE DOOR, HALF LITE (*4" HEAD FRAME)

HARDWARE SETS

SET 7 - EXTERIOR DOUBLE DOORS

(3) HEAVY DUTY HINGES

(1) MORTISE DEADLOCK SET

(1) OVERHEAD CLOSER

(1) FLUSHBOLT SET

(1) ASTRAGAL

(1) COORDINATOR

(2) WALL OR FLOOR STOPS

(4) KICK PLATES

(1) THRESHOLD

(2) WEATHERSTRIPPING

SET 8 - EXTERIOR SINGLE DOORS WITH CLOSER

(3) HEAVY DUTY HINGES

(1) MORTISE DEADLOCK SET

(1) WALL OR FLOOR STOP

(2) KICK PLATES

(1) OVERHEAD CLOSER

(1) THRESHOLD

(2) WEATHERSTRIPPING

NOT TO SCALE1 APPLIANCE SHOP - MAIN LEVEL

NOT TO SCALE2 APPLIANCE SHOP - LOWER LEVEL

NOT TO SCALE3 POWERHOUSE 1st FLOOR

NOT TO SCALE4 POWERHOUSE - 2ND FLOOR

GENERAL DEMOLITION NOTES

1. ABATEMENT CONTRACTOR SHALL REMOVE

AND ABATE AREA AROUND EXTERIOR DOORS.

GENERAL CONTRACTOR TO COORDINATE WITH

ABATEMENT CONTRACTOR TO PROVIDE

TEMPORARY OPENING PROTECTIVES AND

DOORS.

2. TEMPORARY OPENING PROTECTIVES TO BE

3/4" PLYWOOD WITH PLYWOOD DOORS.

HARDWARE TO INCLUDE HINGES, HANDLE,

SPRING CLOSER AND HINGED HASP FOR USE

WITH OWNER PROVIDED PADLOCK.

3. TEMPORARY OPENING PROTECTIVES TO

REMAIN IN PLACE UNTIL NEW DOORS AND

SECURITY HARDWARE INSTALLED AND

FUNCTIONING.

/7