RFB 930300-02 2023 - NCCF Grease Interceptor Drawings.pdf
PDF 2 MB Posted
- Attached to
- DOC NCCF Kitchen Grease Interceptor
- Solicitation number
- RFB930300-02
- Issued by
- Calhoun County, Iowa
About this file
This document is a set of construction drawings and specifications for the replacement of the existing kitchen grease interceptor at the North Central Correctional Facility in Rockwell City, Iowa. The project is being managed by the Iowa Department of Administrative Services Division of Business and Property Services. The drawings provide details for demolishing the existing grease interceptors, installing a new 1,000 gallon grease interceptor, related sanitary sewer piping, and site restoration work. The new grease interceptor will be installed on a concrete pad and connected to the existing sanitary sewer system. The work is to be completed within a maximum 3-day shutdown of the grease waste system. Contractor responsibilities include coordinating construction access and staging with the facility, maintaining traffic and pedestrian control, and restoring all disturbed areas.
The drawings specify the use of SUDAS standard specifications for materials and installation. Concrete and sanitary sewer piping requirements are provided. Contractors may submit equivalent grease interceptor models for approval. The contractor is responsible for all dewatering, trenching, and backfill required for the project. Site restoration includes placing 6 inches of topsoil and hydroseeding all disturbed areas not covered by new pavement or gravel surfacing.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B C D E F
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d:
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C000
C O
VE
R
S H
EE
T
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
CO
VE
R
SH
EE
T.
dw g
4/ 7/
:0
3:
P M
PROJECT
LOCATION
PAGES, SHEETS OR DIVISIONS COVERED BY THIS SEAL:
My License Renewal Date is: DECEMBER 31, Printed or typed name:
License Number:
Signature: Date
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT DESCRIBED
BELOW WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL
SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
ALL SHEETS
CHRISTOPHER R. BAUER
19737
CIVIL ENGINEER
DOC NCCF KITCHEN GREASE PIT REPLACEMENT
DAS PROJECT NO: 9303.00
NORTH CENTRAL CORRECTIONAL FACILITY
313 LANEDALE
ROCKWELL CITY, IA 50579
VICINITY MAP
NTS
PROJECT MAP
NTS
PROJECT
LOCATION
ENTRANCE
ROCKWELL
CITY, IA
MAIN ENTRANCE
INTO FACILITY
LIGHT POLE
FIRE HYDRANT
VALVE
CLEANOUT
DRAINAGE MANHOLE
SANITARY MANHOLE
CURB INTAKE
GAS MAIN
SANITARY SEWER
MINOR CONTOUR
STORM SEWER
WATER MAIN
TREE
TREE REMOVAL
CURB AND GUTTER (PCC)
MAJOR CONTOUR
STORM INTAKE
909 909
PROPOSEDDESCRIPTIONEXISTING
FLARED END SECTION
TRANSFORMER
ELECTRICAL LINE
BUILDING
PCC PAVING
PAVING DEMO
GENERAL NOTES
1. THE LOCATIONS OF UTILITY MAINS, STRUCTURES AND SERVICE CONNECTIONS PLOTTED ON THE DRAWINGS ARE APPROXIMATE
ONLY AND WERE OBTAINED FROM RECORDS MADE AVAILABLE TO SHIVE-HATTERY, INC. THERE MAY BE OTHER EXISTING UTILITY MAINS, STRUCTURES AND SERVICE CONNECTIONS NOT KNOWN TO SHIVE-HATTERY, INC. AND NOT SHOWN ON THE DRAWINGS. THE VERIFICATION OF EXISTENCE OF AND THE DETERMINATION OF THE EXACT LOCATION OF UTILITY MAINS, STRUCTURES AND SERVICE CONNECTIONS SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR(S).
2. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL UNCOVER EXISTING UTILITIES AT CRITICAL LOCATIONS TO VERIFY EXACT
HORIZONTAL AND VERTICAL LOCATION.
3. THE FACILITY WILL COMPLETE PRIVATE UTILITY LOCATES OF ALL FACILITY UTILITIES REQUIRED BY IOWA ONE-CALL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL LOCATES AND CONFIRM THEY ARE COMPLETED PRIOR TO THE START OF
CONSTRUCTION.
4. IOWA CODE 480, UNDERGROUND FACILITIES INFORMATION, REQUIRES VERBAL NOTICE TO IOWA ONE-CALL BY CALLING 811 OR 1-800-292-8989 NOT LESS THAN 48 HOURS BEFORE EXCAVATING, EXCLUDING WEEKENDS AND HOLIDAYS.
5. NOTIFY UTILITY COMPANIES WHOSE FACILITIES ARE SHOWN ON THE PLANS OR KNOWN TO BE WITHIN THE CONSTRUCTION LIMITS
OF THE SCHEDULE PRIOR TO EACH STAGE OF CONSTRUCTION.
6. UNLESS OTHERWISE SPECIFIED, ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE MOST RECENT EDITION OF IOWA
STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS).
7. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE REGULATIONS/CODES AND OSHA STANDARDS.
8. THE MEANS OF THE WORK AND THE SAFETY OF THE CONTRACTOR'S EMPLOYEES ARE SOLELY THE RESPONSIBILITY OF THE
CONTRACTOR.
9. NO WORK SHALL BE PERFORMED BEYOND THE PROJECT LIMITS WITHOUT PRIOR AUTHORIZATION FROM THE OWNER'S
REPRESENTATIVE.
10. PROTECT EXISTING UTILITIES DURING CONSTRUCTION.
11. MAINTAIN POSITIVE DRAINAGE ON THE SITE THROUGHOUT THE PROJECT DURATION.
12. SITE CLEAN-UP SHALL BE PERFORMED ON A DAILY BASIS. DRIVES, ROADWAYS, ETC. SHALL BE KEPT CLEAN AT ALL TIMES.
13. ALL OPEN EXCAVATIONS SHALL BE PROTECTED.
14. REPAIR OR REPLACE DAMAGED SITE FEATURES (WALLS, PAVEMENT, UTILITIES, FENCES, ETC.) TO REMAIN AT NO ADDITIONAL
EXPENSE TO THE STATE.
15. ANY WORK REQUIRED TO COMPLETE THE SCOPE OF THIS PROJECT BUT NOT SPECIFICALLY CALLED OUT SHALL BE CONSIDERED INCIDENTAL TO THE PROJECT. NO ADDITIONAL COMPENSATION TO BE ALLOWED FOR THE COMPLETION OF THIS WORK.
16. WORK WHICH DOES NOT CONFORM TO THE REQUIREMENTS OF THE CONTRACT WILL BE CONSIDERED UNACCEPTABLE.
UNACCEPTABLE WORK, WHETHER THE RESULT OF POOR WORKMANSHIP, USE OF DEFECTIVE MATERIALS, DAMAGE THROUGH CARELESSNESS OR ANY OTHER CAUSE FOUND TO EXIST PRIOR TO THE FINAL ACCEPTANCE OF THE WORK SHALL BE REMOVED AND REPLACED IN AN ACCEPTABLE MANNER AS REQUIRED BY THE OWNER'S REPRESENTATIVE AT THE CONTRACTOR'S EXPENSE.
WORK DONE CONTRARY TO THE INSTRUCTIONS OF THE OWNER'S REPRESENTATIVE, WORK DONE BEYOND THE LINES SHOWN ON THE PLANS OR ANY EXTRA WORK DONE WITHOUT WRITTEN AUTHORIZATION WILL NOT BE PAID FOR.
17. CONTOURS AND SPOT ELEVATIONS SHOWN ARE TO FINISHED GRADE.
18. THE CONTRACTOR SHALL MATCH EXISTING GRADES AT THE CONSTRUCTION LIMITS.
19. STAGING LOCATIONS AND CONSTRUCTION ACCESS ROUTES FOR CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE
COORDINATED WITH AND APPROVED BY THE FACILITY AND CONSTRUCTION MANAGER.
20. THE CONTRACTOR SHALL PROVIDE EROSION CONTROL MEASURES NECESSARY TO PROTECT AGAINST SILTATION, EROSION AND DUST POLLUTION ON THE PROJECT SITE AND ANY OFF-SITE BORROW OR DISPOSAL AREAS USED FOR THIS PROJECT. COMPLY WITH SOIL EROSION CONTROL REQUIREMENTS OF IOWA CODE, FEDERAL REGULATIONS AND LOCAL ORDINANCES.
21. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SEEDED PER THE SPECIFICATIONS. A MINIMUM OF 6" OF TOPSOIL SHALL BE
PROVIDED PER SPECIFICATIONS.
22. CONTROL DUST SPREADING FROM ALL WORK AND STAGING AREAS.
23. CONTRACTOR TO COORDINATE ANY SITE, UTILITY OR GRADE ADJUSTMENTS WITH THE CONSTRUCTION MANAGER PRIOR TO
PROCEEDING WITH THE WORK.
24. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF WORK OF ALL SUBCONTRACTOR(S) INVOLVED ON THE
PROJECT.
25. SIGNING, STRIPING OR OTHER TRAFFIC CONTROL DEVICES ON THE ROADWAY SHOULD CONFORM TO THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD, FEDERAL HIGHWAY ADMINISTRATION, 2009 EDITION)
OWNERENGINEER
IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DIVISION OF BUSINESS AND PROPERTY SERVICES
ATTN: JAMES TROWER
JAMES.TROWER@IOWA.GOV
109 SE 13TH STREET
DES MOINES, IA 50319
515-380-8049
SHIVE-HATTERY, INC.
ATTN: CHRIS BAUER OR KYLE LAWSON
CBAUER@SHIVE-HATTERY.COM
KLAWSON@SHIVE-HATTERY.COM
4125 WESTOWN PKWY, SUITE 100
WEST DES MOINES, IA 50266
515-223-8104
SITE ADDRESS
NORTH CENTRAL CORRECTIONAL FACILITY
313 LANEDALE
ROCKWELL CITY, IA 50579
CONSTRUCTION MANAGER
STORY CONSTRUCTION
ATTN: DARREN MILLIKEN
DARREN.MILLIKEN@STORYCON.COM
2810 WAKEFIELD CIRCLE
AMES, IA 50010
515-291-5358
BOLLARD
CONTACT INFORMATION
Sheet List Table Sheet Number Sheet Title
C000 COVER SHEET
C001 CONSTRUCTION NOTES
CD01 DEMOLITION PLAN
C101 SITE PLAN
C301 UTILITY PLAN
C302 UTILITY PROFILE
C501 CONSTRUCTION DETAILS
4-10-2023
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d:
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C001
C O
N
ST
R U
C
TI
O N
N O
TE
S
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
CO
NS
TR
UC
TI
O
N
NO
TE
S.
dw g
4/ 7/
:0
3:
P M
CONSTRUCTION STAGING NOTES
1. CONTRACTOR TO COORDINATE CONSTRUCTION ACCESS, STAGING AND CONSTRUCTION PARKING AREAS WITH FACILITY AND
CONSTRUCTION MANAGER AND MINIMIZE IMPACTS TO FACILITY'S OPERATIONS.
2. CONTRACTOR SHALL REPLACE ALL ADJACENT PAVEMENT DAMAGED BY CONSTRUCTION ACTIVITIES AT THE END OF CONSTRUCTION. CONTRACTOR TO PROVIDE PHOTO DOCUMENTATION OF EXISTING CONDITIONS PRIOR TO BEGINNING WORK.
3. CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS NOT TO BE PAVED TO THEIR ORIGINAL GRADES AND CONDITION AT THE END OF CONSTRUCTION. ALL DISTURBED AREAS SHALL BE SCARIFIED, TILLED AND SEEDED.
4. CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES, FENCING OR OTHER DEVICES TO KEEP UNAUTHORIZED
PERSONNEL OUT OF PROJECT SITE.
TRAFFIC AND PEDESTRIAN CONTROL NOTES
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTROL TRAFFIC DURING CONSTRUCTION AND PROVIDE ADEQUATE TRAFFIC AND PEDESTRIAN CONTROL AND SIGNAGE. AT A MINIMUM, CONTRACTOR TO PROVIDE TYPE III BARRICADES AT EACH END OF
CLOSED ROADS AND DRIVES. COORDINATE ROAD CLOSURE REQUIREMENTS WITH FACILITY.
2. AT A MINIMUM, CONTRACTOR TO INSTALL AND MAINTAIN ORANGE CONSTRUCTION FENCE AROUND ALL AREAS OF ACTIVE CONSTRUCTION. CONTRACTOR SHALL ASSUME PEDESTRIAN TRAFFIC WILL BE IN THE AREA THROUGHOUT THE PROJECT
DURATION.
DEMOLITION NOTES
1. REMOVAL REQUIREMENTS SHOWN ON THE PLANS SHOULD BE CONSIDERED MINIMUM REMOVAL AND REPLACEMENT REQUIREMENTS. CONTRACTORS SHALL ADJUST REMOVAL LIMITS AND DIMENSIONS AS REQUIRED BY CONSTRUCTION MEANS AND METHODS AND ACTUAL SITE CONDITIONS. CONTRACTORS SHOULD FACTOR ADDITIONAL ANTICIPATED REMOVAL AND REPLACEMENT REQUIREMENTS INTO THEIR BIDS AS ADDITIONAL COMPENSATION REQUESTS FOR ADJUSTED OR EXPANDED
REMOVAL LIMITS WILL NOT BE APPROVED.
2. CONTRACTOR SHALL REPLACE AT NO COST TO THE STATE ALL DAMAGED STREETS, DRIVES, SIGNS, LIGHTS, FENCES AND ALL OTHER SURFACE STRUCTURES NOT SCHEDULED TO BE REMOVED DURING THE COURSE OF THE WORK.
3. THE CONTRACTOR SHALL COORDINATE ANY DISRUPTION OF EXISTING UTILITIES SERVING THE FACILITY WITH THE FACILITY
AND CONSTRUCTION MANAGER.
4. SITE LIGHTING SHALL BE MAINTAINED AT ALL TIMES THROUGHOUT CONSTRUCTION. IF SITE ELECTRICAL LINES REQUIRE RELOCATION , WORK SHALL BE COMPLETED SUCH THAT THERE ARE NO OUTAGAGES OF SITE LIGHTING DURING EVENING OR
NIGHT HOURS.
5. ALL COMPONENTS OF MANHOLE ENTRY TIE OFF STRUCTURE, INCLUDING METAL STRUCTURE AND FOOTINGS, TO BE
REMOVED AND DISPOSED OF OFFSITE.
6. REMOVE AND DISPOSE OF THE LIDS, MANHOLE EXTENSIONS, AND THE CONCRETE TANK CAPS OF THE TWO EXISTING GREASE INTERCEPTORS. ALL INLET AND OUTLET PIPES SHOULD BE PERMANENTLY CAPPED WITH PIPE FITTINGS OR CONCRETE.
TANKS SHOULD BE ABANDONED IN PLACE AND FILLED WITH COMPACTED SAND OR GRANULAR MATERIAL TO THE TOPS OF
THE TANK WALLS. COMPACTED SOIL MATERIAL CAN BE PLACED ABOVE STRUCTURES.
EXCAVATION NOTES
1. EXCAVATE GREASE INTERCEPTOR AND PROPOSED BEDDING AND BACKFILL MATERIAL PER MANUFACTURER RECOMMENDATIONS OR AS REQUIRED BY DRAWINGS AND SPECIFICATIONS. SAND BACKFILL OF NEW GREASE INTERCEPTOR
STRUCTURE WILL NOT BE ALLOWED AND SHOULD BE SUBSTITUTED WITH GRANULAR MATERIAL.
2. EXCAVATE TRENCH AND PROVIDE PIPE BEDDING AND BACKFILL MATERIAL PER IOWA SUDAS SPECIFICATIONS UNLESS
OTHERWISE SHOWN ON THE DRAWINGS.
3. STRIP, STOCKPILE AND RESPREAD A MINIMUM OF 6” OF TOPSOIL IN ALL SEEDING AREAS DISTURBED BY CONSTRUCTION.
GRADE ALL DISTURBED AREAS TO DRAIN, AS PONDING OF WATER WILL NOT BE ACCEPTABLE.
4. CONTRACTOR IS RESPONSIBLE FOR ALL BACKFILL AND FILL SETTLEMENT FOR THE PROJECT'S ONE YEAR WARRANTY PERIOD.
CONTRACTOR SHALL PROVIDE ADDITIONAL FILL MATERIAL AND IS RESPONSIBLE FOR RESEEDING OF ALL SETTLEMENT AREAS
AFTER SITE RESTORATION HAS BEEN COMPLETED.
5. ALL DEBRIS, ROCK OR CONCRETE WASTE, AND EXCESS SOIL SHALL BE DISPOSED OF OFF SITE.
GRADING AND EROSION CONTROL NOTES
1. ALL WASH WATER (CONCRETE TRUCKS, VEHICLE CLEANING, EQUIPMENT CLEANING, TANK CLEANING, ETC.) SHALL BE
DETAINED AND PROPERLY TREATED OR DISPOSED OF OFFSITE.
2. SUFFICIENT OIL AND GREASE ABSORBING MATERIALS SHALL BE MAINTAINED ON SITE OR READILY AVAILABLE TO CONTAIN
AND CLEAN UP FUEL OR CHEMICAL SPILLS AND LEAKS.
3. DUST ON THE SITE SHALL BE CONTROLLED. THE USE OF MOTOR OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR
DUST SUPPRESSION OPERATIONS IS PROHIBITED.
4. RUBBISH, TRASH, GARBAGE, LITTER OR OTHER SUCH MATERIALS SHALL BE DEPOSITED INTO SEALED CONTAINERS.
MATERIALS SHALL BE PREVENTED FROM LEAVING THE PREMISES THROUGH THE ACTION OF WIND OR STORMWATER
DISCHARGE INTO DRAINAGE DITCHES OR WATERS OF THE STATE.
5. ALL MATERIALS SPILLED, DROPPED, WASHED OR TRACKED FROM VEHICLES ONTO ROADWAYS OR INTO STORM DRAINS MUST
BE REMOVED IMMEDIATELY.
6. ALL STORM SEWER INTAKES THAT RECEIVE STORMWATER RUNOFF FROM DISTURBED AREAS SHALL BE PROVIDED WITH
INLET PROTECTION.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION, PERIODIC CHECKING AND REINSTALLATION OF EROSION AND
SEDIMENTATION CONTROL MEASURES.
8. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE IOWA DNR, US EPA AND LOCAL REGULATIONS DEALING WITH
STORMWATER RUNOFF AND EROSION CONTROL.
9. THE DISTURBED CONSTRUCTION AREA IS LESS THAN 1 ACRE, SO AN NPDES GENERAL PERMIT NO. 2 AND STORMWATER POLLUTION PREVENTION PLAN (SWPPP) ARE NOT REQUIRED. HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING
AND MAINTAINING ADEQUATE EROSION CONTROL THROUGHOUT CONSTRUCTION.
UTILITY NOTES
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE EXACT LOCATIONS AND DEPTHS OF ALL EXISTING PUBLIC AND
PRIVATE UTILITIES AND WHETHER ADDITIONAL UTILITIES EXIST.
2. ALL CLEANOUTS IN LAWN OR GRANULAR AREAS SHALL HAVE CONCRETE COLLARS.
3. ALL EXISTING AND PROPOSED PUBLIC AND PRIVATE UTILITY STRUCTURES SHALL BE ADJUSTED TO FINAL FINISH GRADES.
4. ALL PIPE BENDS AND CONNECTIONS SHALL BE MANUFACTURED CONNECTIONS.
5. CONTRACTOR TO MODIFY PROPOSED PIPE AND STRUCTURE INVERTS TO ACCOMMODATE EXISTING PIPE CONNECTIONS.
6. ALL UNDERGROUND LINES SHALL BE INSTALLED, DOCUMENTED, REVIEWED BY CONSTRUCTION MANAGER, AND APPROVED
BEFORE BACKFILLING.
7. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH IOWA SUDAS STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED
ON THE DRAWINGS OR SPECIFICATIONS.
8. ALL OPEN EXCAVATIONS SHALL BE PROTECTED WITH SAFETY FENCE, BARRIERS OR BARRICADES IN ACCORDANCE WITH
OSHA STANDARDS.
9. CONTRACTOR TO IMPLEMENT TEMPORARY SHORING OR SUPPORT AT ALL EXCAVATIONS AS REQUIRED BY CONTRACTOR'S MEANS AND METHODS. ALL DAMAGE TO EXISTING SITE IMPROVEMENTS AND UTILITIES SHALL BE REPAIRED AT NO
ADDITIONAL COST TO THE STATE.
SPECIFICATIONS
THE MOST RECENT EDITION OF THE IOWA STATEWIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) SHALL APPLY TO ALL SITE
WORK PERFORMED ON THIS PROJECT EXCEPT AS MODIFIED HEREIN.
A. CONCRETE PAVING
CONCRETE: MATERIALS AND MIXING FOR ALL CONCRETE WORK, UNLESS OTHERWISE SPECIFIED, SHALL CONFORM TO IOWA DOT
SPECIFICATIONS FOR AIR-ENTRAINED TYPE C-4 MIX WITH TYPE I CEMENT
FLY ASH: (CONTRACTOR'S OPTION AS ADDITIONAL PAYMENT WILL NOT BE PROVIDED IF FLY ASH IS NOT AVAILABLE) - ASTM C618, TYPE C, NOT TO EXCEED 15% OF CEMENTITIOUS MATERIAL.
COARSE AGGREGATE DURABILITY SHALL BE CLASS III, 3/4" MAX.
COMPRESSIVE STRENGTH: 2800 PSI @ 7 DAYS AND 4000 PSI @ 28 DAYS
SLUMP: 3" ± 1" or 8" MAXIMUM WITH SUPER PLASTICIZER.
AIR CONTENT: 7.0% ± 1.0%
WATER/CEMENT RATIO: NOT TO EXCEED 0.53
FINISH: MATCH EXISTING FINISH FOR ROADWAY AND DRIVE PATCHING.
TESTING - ONE SET OF TEST CYLINDERS REQUIRED FOR EACH 100 C.Y. OR PORTION THEREOF, OF CONCRETE POURED PER WORK LOCATION. CONCRETE TESTING TO BE DONE AND PAID FOR BY OWNER. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL
REQUIRED TESTING AND GEOTECHNICAL WORK.
SURFACE CURING: CONTRACTOR SHALL APPLY WHITE PIGMENT LIQUID CURING COMPOUND IN A FINE SPRAY TO FORM CONTINUOUS UNIFORM FILM AFTER FINISHING AND SURFACE MOISTURE HAS DISAPPEARED, OR WITHIN 30 MINUTES AFTER
FORMS ARE REQUIRED.
JOINTING: INSTALL JOINT LAYOUT TO MATCH EXISTING.
INSTALL TYPE 'RD' JOINTS AT ALL SIDES ABUTTING EXISTING PAVEMENT.
INSTALL TYPE 'CD' DOWELED CONTRACTOR JOINT FOR ALL NEW TRANSVERSE JOINTS.
PROVIDE OWNERS REPRESENTATIVE WITH CONCRETE MIX DESIGN FOR APPROVAL.
B. SITE REMOVALS AND ABANDONMENTS
GREASE WASTE SYSTEM MAY BE SHUT DOWN FOR A MAXIMUM OF THREE (3) DAYS TO ACCOMMODATE WORK THAT NEEDS TO BE PERFORMED WHILE THE SYSTEM IS SHUT DOWN. SYSTEM SHUTDOWN TO BE COMMUNICATED TO FACILITY A MINIMUM OF TWO (2) WEEKS PRIOR TO BEGINNING OF SHUTDOWN AND MUST BE COORDINATED WITH FACILITY AND CONSTRUCTION MANAGER.
SANITARY SEWER TO BE ABANDONED SHALL BE PERMANENTLY CAPPED WITH MANUFACTURED PIPE FITTINGS OR ENGINEER
APPROVED CONCRETE CAPS.
EXISTING GREASE INTERCEPTORS CONCRETE LIDS, RISERS, MANHOLES AND CLEANOUTS TO BE REMOVED IN THEIR ENTIRETIES
AND DISPOSED OF OFFSITE.
PRIOR TO ABANDONMENT, ALL LIQUID AND GREASE CONTENTS WITHIN EXISTING GREASE INTERCEPTORS SHALL BE PUMPED OUT AND FLOORS AND WALLS SHALL BE POWER WASHED OR SCRAPED CLEAN. A MINIMUM OF SIX (6 ) HOLES SHALL SHALL BE DRILLED OR BROKEN IN THE FLOORS OF THE EXISTING TANKS TO ALLOW FOR WATER EXFILTRATION. THE STRUCTURES SHALL BE COMPLETELY FILLED WITH COMPACTED SAND OR GRANULAR MATERIAL AND THEN COVERED WITH COMPACTED SOIL.
ALL EXISTING GRANULAR SURFACING TO BE REMOVED AND DISPOSED OF PRIOR TO SITE RESTORATION AND REPLACED WITH
TOPSOIL FOR ALL SEEDED AREAS.
C. GREASE INTERCEPTOR
REFER TO PROJECT MANUAL AND SANITARY WASTE PIPING SPECIALTIES TECHNICAL SPECIFICATION SECTION FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
INSTALL GREASE INTERCEPTOR AND ALL ASSOCIATED COMPONENTS ACCORDING TO ALL MANUFACTURER RECOMMENDATIONS
AND ACCORDING TO DRAWING AND SPECIFICATION REQUIREMENTS.
GREASE INTERCEPTOR DESIGN BASIS IS A SCHIER MODEL GB-1000 GREASE INTERCEPTOR. CONTRACTORS MAY SUBMIT
EQUIVALENT MODELS FOR APPROVAL BY ENGINEER.
GREASE INTERCEPTOR SHALL HAVE MANUFACTURER APPROVED ANTI-FLOTATION STRAPS INSTALLED.
CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING, WHICH MAY BE REQUIRED INCIDENTAL TO THE TANK INSTALLATION.
D. SANITARY SEWER / GREASE WASTE PIPING
VERIFY THE EXACT LOCATIONS AND DEPTHS OF ALL EXISTING PIPES PRIOR TO CONSTRUCTION OF PROPOSED IMPROVEMENTS.
ADJUST PROPOSED ELEVATIONS AND LOCATIONS AS REQUIRED BASED ON EXISTING CONDITIONS.
SANITARY SEWER PIPING MATERIALS AND INSTALLATION SHALL CONFORM TO SUDAS STANDARDS.
SANITARY SEWER PIPING SHALL BE SOLID WALL POLYVINYL CHLORIDE PIPE (PVC) SDR 26 WITH A MINIMUM PIPE STIFFNESS OF 115
PSI. PER ASTM D 2412.
E. VENT PIPING
VENT PIPING SHALL BE SCHEDULE 40 PVC FOR ENTIRE LENGTH OF VENT PIPING.
ENCLOSE BASE OF ABOVE-GROUND VENT PIPING IN PROTECTIVE METAL SHROUD FOR A MINIMUM OF 4' FROM GROUND SURFACE TO PROTECT FROM LAWN MAINTENANCE EQUIPMENT. SUBMIT PROPOSED METAL SHROUD FOR APPROVED BY ENGINEER.
MOUNT VENT PIPING TO POLE WITH STAINLESS STEEL STRAPS AND STAINLESS STEEL HARDWARE. PIPE SUPPORT TO BE A
MAXIMUM OF 8' ALONG POLE AND
ROUTE VENT PIPING PIPING TO 3' ABOVE TOP OF POLE AND INSTALL A MINIMUM OF ONE ADDITIONAL STRAP TO FIRMLY SECURE
TO POLE.
CUT AND REMOVE PORTIONS OF EXISTING POLE CONCRETE BASE TO ALLOW FOR ROUTING OF VENT UP SIDE OF POLE.
F. TRENCH EXCAVATION AND BACKFILL
BEDDING AND BACKFILL MATERIAL: SHALL COMPLY WITH IOWA SUDAS SECTION 3010.
BACKFILL COMPACTION REQUIREMENTS: AREAS UNDER LANDSCAPING AND LAWN AREAS SHALL BE COMPACTED TO 90% OF
MAXIMUM STANDARD PROCTOR DENSITY.
CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING, WHICH MAY BE REQUIRED INCIDENTAL TO THE PIPE INSTALLATION.
G. TOPSOIL
STRIP, STOCKPILE AND RESPREAD EXISTING TOPSOIL IN ALL AREAS TO BE SEEDED. THE DEPTH OF TOPSOIL SHALL BE A MINIMUM OF 6" AFTER NATURAL SETTLEMENT AND SHALL CONFORM SMOOTHLY TO THE ADJACENT LINES, GRADES AND ELEVATIONS.
PROVIDE ADDITIONAL TOPSOIL AS REQUIRED OR IF EXISTING TOPSOIL IS NOT PROPERLY HANDLED AND PROTECTED.
H. SITE RESTORATION
HYDRAULIC SEEDING: ALL DISTURBED AREAS ON THE SITE NOT TO BE PAVED OR LANDSCAPED SHALL RECEIVE HYDRAULIC SEEDING. HYDRAULIC SEEDING MATERIALS AND INSTALLATION SHALL MEET SUDAS SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE FOR PREPARING SEEDBED, APPLYING HYDRAULIC SEEDING AND FIRST AND SECOND APPLICATIONS OF FERTILIZER.
SEED MIXTURE: SUDAS TYPE 1 SEED MIXTURE (PERMANENT LAWN MIXTURE) OR APPROVED EQUAL.
I. GRANULAR SURFACING
MATERIALS AND INSTALLATION TO MEET IDOT SPECIFICATION 4120, CLASS A ROADSTONE OR APPROVED EQUAL.
THE MOST RECENT EDITION OF THE IOWA STATEWIDE URBAN DESIGN
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS SHALL APPLY TO ALL
WORK PERFORMED ON THIS PROJECT EXCEPT AS MODIFIED HEREIN.
SANITARY MH
RIM=1214.88'
IE=1199.73'
IE = 1208.12
6" S
ANITARY
4" S
ANITARY
4" S
ANITARY
8" SANITARY
6" S
AN
IT
AR
Y
IE =1210.00
IE =1210.00
IE =1210.00
SANITARY CLEANOUT DROP
IE IN = 1208.02
IE OUT = 1199.70
IE = 1199.55
IE = 1208.37
IE = 1208.27
IE = 1208.22
6" SAN
ABANDON EXISTING
SANITARY SEWER
REMOVE AND DISPOSE OF
EXISTING GREASE INTERCEPTOR
MANHOLES AND CLEANOUT
PUMP, CLEAN AND FILL EXISTING
GREASE INTERCEPTORS WITH
SAND. ABANDON IN PLACE (TYP)
PROTECT EXISTING
SANITARY SEWER
REMOVE AND DISPOSE
OF EXISTING GRANULAR
SURFACING (TYP)
PROTECT EXISTING
LIGHT POLE
PROTECT EXISTING
SANITARY SEWER
PROTECT
EXISTING FENCING
PROTECT EXISTING
LIGHT POLE
PROTECT OR RELOCATE EXISTING
ELECTRICAL SERVICE. ELECTRICAL
SERVICE TO BE MAINTAINED
THROUGHOUT CONSTRUCTION.
COORDINATE WITH OWNER.
REMOVE AND DISPOSE OF
EXISTING TIE-OFF STRUCTURE
AND FOUNDATIONS (TYP)
REMOVE AND DISPOSE OF
EXISTING GREASE INTERCEPTOR
TANK CONCRETE LIDS (TYP)
CONTRACTOR TO COORDINATE
SHUTDOWN OF PERIMETER
ROAD WITH OWNER
GREASE WASTE SYSTEM TO BE SHUT
DOWN FOR A MAXIMUM OF THREE
DAYS. CONTRACTOR TO COORDINATE
SHUTDOWN WITH OWNER.
ABANDON EXISTING
SANITARY SEWER
PROVIDE A PERMANENT CAP ON
EXISTING SANITARY SEWER AND
PROVIDE DETAILED RECORD DRAWINGS
OF LOCATION WITH PICTURE
REMOVE AND DISPOSE
OF EXISTING PCC PAVING
TO NEAREST JOINT
SAWCUT PAVING
FULL DEPTH
A B C D E F
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d:
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: CD01
D
EM
O
LI
TI
O
N
PL
AN
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
D0
DE
M
O
LI
TI
O
N
PL
AN
.d wg 4/
7/
:0 3:
P
M
IE=1199.73'
IE = 1208.12
6" S
ANITARY
4" S
ANITARY
4" S
ANITARY
8" SANITARY
6" S
AN
IT
AR
Y
IE =1210.00
IE =1210.00
IE =1210.00
SANITARY CLEANOUT DROP
IE IN = 1208.02
IE OUT = 1199.70
IE = 1199.55
IE = 1208.37
IE = 1208.27
IE = 1208.22
6" SAN
0+00
0+50
INSTALL GRANULAR
SURFACING. MATCH
EXISTING ROCK.
PLACE 6" TOPSOIL AND
HYDROSEED ALL DISTURBED
AREAS NOT TO BE COVERED
WITH GRANULAR SURFACING
PCC PAVING
(TYP)
A B C D E F
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C101
SI
TE
P
LA
N
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
SI
TE
P
LA
N.
dw g 4/
7/
:0 3:
P
M
C302
C302
IE=1199.73'
IE = 1208.12
6" S
ANITARY
4" S
ANITARY
4" S
ANITARY
8" SANITARY
6" S
AN
IT
AR
Y
IE =1210.00
IE =1210.00
IE =1210.00
SANITARY CLEANOUT DROP
IE IN = 1208.02
IE OUT = 1199.70
IE = 1199.55
IE = 1208.37
IE = 1208.27
IE = 1208.22
6" SAN
0+00
0+50
RUN VENT PIPING UP LIGHT POLE
TO 3' ABOVE TOP OF POLE.
MOUNT PIPE TO THE POLE EVERY
8 FEET WITH STAINLESS STEEL
PIPE STRAPS AND HARDWARE.
CONNECT TO EXISTING
SANITARY SEWER
IE = 1208.44
CONTRACTOR TO FIELD VERIFY EXACT
HORIZONTAL AND VERTICAL LOCATION
OF GREASE LINE AND ADJUST
PROPOSED GRADES AS REQUIRED
SAN 1.3 17 LF 6" PVC
SANITARY SEWER @ 1.00%
GREASE INTERCEPTOR
SCHIER GB-1000 100 GPM
INTERCEPTOR OR APPROVED EQUAL
RIM (NW) = 1214.47
RIM (SE) = 1214.41
IE = 1208.27 SAN 1.3
IE = 1208.10 SAN 1.2
SEE DETAIL AND SPECIFICATIONS
SAN 1.1 4 LF 6" PVC
CONNECT TO EXISTING SANITARY
SEWER WITH APPROVED FITTING
IE = 1199.93
SAN MH 1.1 SW-301 (48")
RIM = 1214.18
IE = 1208.03 SAN 1.2
IE = 1200.43 SAN 1.1
SAN 1.2 7 LF 6" PVC
SANITARY SEWER @ 1.00%
SANITARY IN-LINE
2-WAY CLEANOUT
IE = 1208.30
INSTALL 17 LF 2" SCH 40
PVC GREASE INTERCEPTOR
VENT TO LIGHT POLE
ANCHOR GREASE INTERCEPTOR
WITH MANUFACTURER
RECOMMENDED
ANTI-BUOYANCY TIE-DOWNS
REMOVE PORTIONS OF
EXISTING GREASE
INTERCEPTOR WALLS TO
ALLOW FOR PROPOSED PIPING
BOTTOM 4' OF VENT TO BE
ENCLOSED IN METAL SHROUD
APPROVED BY ENGINEER
45° BEND
EXISTING POLE HAS A CONCRETE
BASE - CONTRACTOR TO CUT
CONCRETE AS NECESSARY TO
ROUTE VENT PIPE
45° BEND
PROTECT EXISTING TANKS
DURING EXCAVATION AND ADJUST
PROPOSED MANHOLE LOCATION
AS REQUIRED TO ACCOMMODATE
EXISTING TANK FOUNDATIONS
A B C D E F
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d:
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C301
U
TI
LI
TY
P
LA
N
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
UT
IL
IT
Y
PL
AN
.d wg
4/ 7/
:0
4:
P M
PHASING NOTES
1. CONTRACTOR TO PHASE CONSTRUCTION
AS REQUIRED TO MAINTAIN EXISTING
SYSTEM AND LIMIT IMPACTS TO GREASE LINE.
2. MAINTAIN EXISTING GREASE WASTE AND
GREASE INTERCEPTOR TO PROVIDE A
MAXIMUM OF THREE (3) DAYS WHEN GREASE
LINE IS OUT OF SERVICE.
3. CONTRACTOR TO PROVIDE DETAILED
CONSTRUCTION AND PHASING PLAN TO
CONSTRUCTION MANAGER.
4. TEMPORARY SHUT DOWNS OF ADJACENT
ROAD WILL BE ALLOWED TO ACCOMMODATE
CONSTRUCTION. OBTAIN PRIOR APPROVAL
FROM FACILITY PRIOR TO SHUT DOWNS.
0+00
.7
0+50
.2
.6
.1
A B C D E F
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d:
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C302
U
TI
LI
TY
P R
O
FI
LE
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
UT
IL
IT
Y
PL
AN
.d wg
4/ 7/
:2
1:
P
M PROFILE VIEW - STA. 0+00 TO 0+50
PERIMETER
FENCE
4' FOUNDATION
WALL
EXISTING GRAVEL
(TO BE REMOVED)
ELECTRICAL SERVICE
(UNKNOWN DEPTH)
EXISTING GREASE INTERCEPTOR
(TO BE ABANDONED)
6" SANITARY SEWER
(TO BE ABANDONED)
PROPOSED
GRAVEL
6" PROPOSED
SANITARY SEWER
PROPOSED
GREASE
INTERCEPTOR
8" SANITARY SEWER - CONTRACTOR
TO VERIFY EXACT HORIZONTAL AND
VERTICAL LOCATION AND ADJUST
PROPOSED LIMITS AS REQUIRED
PERIMETER
ROAD
EXISTING
GRADE
PROVIDE 12" MINIMUM
SEPARATION FOR
BACKFILL
3.5' THICK CONCRETE PAD - MIN. 1' LARGER
THAN TANK IN ALL DIRECTIONS. COORDINATE
INSTALLATION OF MANUFACTURER
RECOMMENDED ANTI-BUOYANCY TIE-DOWNS.
MINIMUM 6" GRANULAR
LEVELING COURSE AS
RECOMMENDED BY
TANK MANUFACTURER
GRANULAR BACKFILL
COMPACTED AS
RECOMMENDED BY
TANK MANUFACTURER
PROTECT EXISTING TANK DURING EXCAVATION
AND ADJUST PROPOSED CONCRETE PAD AS
REQUIRED TO ACCOMMODATE EXISTING TANK
AND TANK FOUNDATION SLAB
W
ES
TO
W
N P
KW
Y, S U
IT
E
W
ES
T D
ES
M
O
IN
ES
, I
O W
A
5.
3.
S
H
IV
E- H
AT
TE
R Y.
C O
M
A B C D E F
D R
AW
N
B Y
AP
PR
O
VE
D B
Y
IS
SU
ED
F
O R
IS
SU
E D
AT
E
FI
EL
D B
O O
K
PR
O
JE
C
T N
U M
BE
R
Pr in te d: C501
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
KA
L
CR
B
CO
NS
TR
UC
TI
O
N
/0
7/
1 ---
.0
D O
C N
C C
F
KI
TC
H
EN
G
R
EA
SE
P
IT
R
EP
LA
C
EM
EN
T
IO
W
A
DE
PA
RT
M
EN
T O
F
AD
M
IN
IS
TR
AT
IV
E
SE
RV
IC
ES
LA
NE
DA
LE
, R O
CK
W
EL
L
CI
TY
, I A
\\s h.
sh ive
-h at te ry
.c om
\D
AT
A\ Pr oj ec ts \D
M \4
\D el ive ra bl es \D ra wi ng s\
1_ Ci vil \C
CO
NS
TR
UC
TI
O
N
DE
TA
IL
S.
dw g 4/
7/
:0 4:
P
M
D4 SANITARY SEWER MANHOLE (SW-301)
A2 SANITARY SEWER CLEANOUT D2 FLEXIBLE PIPE BEDDING
A4 GREASE INTERCEPTOR
Infiltration Barrier
Precast Riser Sections
Location Station Precast Top
Adjustment Rings
Lowest Flowline
Class 1 Bedding Material
Flexible Pipe Connection (typ.)
Precast Base with Integral Riser Section
For additional configurations, maintain a minimum of 12 inches of concrete between vertical edges of pipe openings.
12 inch minimum riser height above all pipe openings.
Maximum Pipe Diameter (inches) for 2 PipesManhole
Diameter (inches) At 180
Separation At 90
Separation
SW-601 Casting
27'' dia.
Joint Sealant (typ.)Manhole Diameter
Steps (typ.)
Depth
Invert
12'' min.
12'' min.
8'' min.
TYPICAL SECTION
PLAN
SUBGRADE SHOULD BE EXCAVATED OR OVER
EXCAVATED, IF NECESSARY, SO A UNIFORM
FOUNDATION FREE OF PROTRUDING ROCKS
MAY BE PROVIDED.
OD
4" (MIN)
T
TW
OD = OUTSIDE DIAMETER OF PIPE
TW = TRENCH WIDTH AT 12" ABOVE
TOP OF PIPE:
MIN. = OD + 18" OR 1.25 x OD + 12"
(WHICHEVER IS GREATER)
NOTE:
OR 1/4 THE DIAMETER
(WHICHEVER IS GREATER)
UNDISTURBED
SOIL
GRANULAR
CRADLE
APPROVED STAINLESS
STEEL ANCHOR BOLT-6
BOLTS MINIMUM
IN-LINE
PLUG
CLEANOUT
SEWER MAIN
45° BEND
WYE
4'' MIN.
2'' MIN.
CASTING
CAP
#4 BAR (TYP.)
20'' MIN.
CONCRETE PAD
6'' PVC RISER
NEENAH R-1975-A HEAVY DUTY CASTING
AND LID
DO NOT ALLOW CASTING TO BEAR ON
TOP OF RISER PIPE.
6-INCH PVC SERVICE PIPE
THREADED PVC CAP OR IRON BODY
FERRULE WITH BRASS SCREW PLUG
2'' MIN.
CASTING
CAP
PAVED AREAS NON-PAVED AREAS
8"
1'-0"
PROPOSED
PAVING
1" EXPANSION
MATERIAL
AROUND
PIPE
POURED
CONCRETE
BASE
TWO-WAY CONNECTION
END OF RUN
SEWER MAIN
SEWER MAIN
PVC RISER
NOTE: SCHIER GREAT BASIN MODEL #GB-1000 IS DESIGN BASIS. CONTRACTOR
MAY PROVIDE EQUIVALENT PRODUCTS FOR APPROVAL BY ENGINEER.
D1 PAVEMENT CROSS-SECTION
7"
SCARIFIED AND
RECOMPACTED SUBGRADE
(95% STANDARD PROCTOR
DENSITY)
EXISTING SUBGRADE OR
COMPACTED FILL (95%
STANDARD PROCTOR
DENSITY)
P.C.C.
PCC PAVING
12"
| 2023-04-10T15:11:33+0000 | |
| SignNow | |
| Digitially Signed Read Only PDF Created by SignNow for Document ID : c91bfb20a8ea4d02b4bacae4a52cfbd8320e8908 |
File details come from the government source that posted it. Updated .