RFB-2025-25 Drawings.pdf
PDF 7 MB Posted
- Solicitation number
- RFB-2025-25
- Issued by
- Schenectady County, New York
About this file
The file is a comprehensive set of architectural and engineering drawings for the SUNY Schenectady County Community College (SCCC) CST Building Lobby and Bathroom Renovations project, prepared by C2 Architecture. The project involves a Level 2 alteration of the building located at 78 Washington Avenue in Schenectady, New York, focusing on renovating the main entry, lobby, corridors, and first and second-floor bathrooms. The drawings, dated November 5, 2024, are part of a bid set (RFB-2025-25) for an HVAC contract, with detailed plans covering architectural, mechanical, electrical, plumbing, and fire protection aspects of the renovation.
The drawings provide a comprehensive overview of the proposed changes, including redesigning the main entry, updating finishes throughout the lobby and corridors, reconfiguring existing bathrooms, and making minor stair modifications. The project involves multiple disciplines, with involvement from C2 Architecture as the architect, Engineered Solutions as the MEP engineer, and SUNY Schenectady as the owner. The bid documents indicate a focus on accessibility, with numerous ADA-compliant design elements and detailed specifications for bathroom renovations, lighting, electrical systems, and mechanical upgrades. The project appears to be funded through SUNY Schenectady and is part of a broader campus improvement initiative.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
W A
SH
IN
G
TO
N A
V E
STATE STREET
Project Description Project Team Project Location
SUNY SCCC CST Building Lobby and Bathroom Renovations
Bid Set | RFB 2024-65
78 Washington Ave. Schenectady, NY 12305
11/05/2024
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:28 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
Cover Sheet
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G100
ARCHITECT:
C2 Architecture, PC
24 Airport Road
Schenectady, NY 12302
T: 518.320.8250
F: 518.320.8252
OWNER:
SUNY Schenectady
78 Washnigton Ave
Schenectady, NY 12305
T: 518.381.1200
MEP ENIGNEER:
Engineered Solutions
646 Plank Rd
Clifton Park, NY 12065
T: 518.280.2410
F: 518.280.2481
PROJECT DESCRIPTION
THE PROJECT SCOPE IS A LEVEL 2 ALTERATION AND INCLUDES A
REDESIGNED MAIN ENTRY, UPDATED FINISHES THROUGHOUT
LOBBY AND CORRIDORS WITH MINOR RE-DESIGN OF STAIRS
WITHIN THE CORRIDOR. IN ADDITION THERE IS RECONFIGURATION
OF EXISTING BATHROOMS WITH UPDATED FINISHES AT THE FIRST
AND SECOND FLOOR LEVELS.
No. REVISION # DATE:
RFB-2025-25 - HVAC CONTRACT BID SET
02/04/2025
KEY NAME FULL NAME
A.B. ANCHOR BOLT
ABR. ABRASIVE FINISH
ACT ACOUSTICAL CEILING TILE
ADH. ADHESIVE
ADJ. ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALUM. ALUMINUM
ALT. ALTERNATE
APPROX. APPROXIMATE
ARCH. ARCHITECT
B/ BOTTOM OF
B/B BACK TO BACK
BD. BOARD
BLDG. BUILDING
BLK BLOCK
BM BEAM
B.O. BOTTOM OF
BOT. BOTTOM
B.A. BEARING PLATE
BR. BRICK
BRG. BEARING
CAB. CABINET
CB CATCH BASIN
CDX. C-D GRADE EXT. PLYWOOD
CF CUBIC FEET
C.H. CABINET HEATER
CIR. CIRCUIT
C.J. CONTROL JOINT
CL CENTER LINE
CLG. CEILING
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
COORD. COORDINATE
CORR. CORRUGATED
CPT CARPET
CRS. COURSES
CSK. COUNTER SINK
CT CERAMIC TILE
C.W. COLD WATER
DET DETAIL
DIA . DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DR DOOR
DWG DRAWING(S)
EA. EACH
E.F. EACH FACE
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
ELEV. ELEVATION
EQ EQUAL
EQUIP. EQUIPMENT
ETR EXISTING TO REMAIN
EXIST. EXISTING
EXP. EXPOSED
EXT. EXTERIOR
F.D. FLOOR DRAIN
F.C. FAN COIL
FDN. FOUNDATION
F.F. FINISH FLOOR
FIN. FINISH
FLG. FLANGE
FLR. FLOOR
FT. FEET
GRP. GROUP
GWB GYPSUM WALL BOARD
GYP. GYPSUM
H.B. HOSE BIB
HC HANDICAP
HDW. HARDWARE
HDWD HARDWOOD
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.P. HIGH POINT
H.S. HIGH STRENGTH
HT. HEIGHT
HVAC HEAT, VENT AND AC
H.W. HOT WATER
H.W.T. HOT WATER TANK
I.D. INSIDE DIAMETER
I.E. INVERT ELEVATION
IN. INCH(ES)
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
JAN. JANITOR
JT. JOINT
LAM. LAMINATED
LAV. LAVATORY
LLH. LONGER LEG HORIZONTAL
LLV. LONGER LEG VERTICAL
LOC. LOCATION
LONG. LONGITUDINAL
L.P. LOW POINT
M. METER
MANUF. MANUFACTURER
MAS. MASONRY
MAT. MATERIAL
MAX. MAXIMUM
M.B. MACHINE BOLTS
MC METAL CHANNEL
M.C. MECHANICAL CONTRACTOR
MECH. MECHANICAL
MED. MEDIUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
M.T. METAL THICKNESS
MTL METAL
N.I.C. NOT IN CONTRACT
NO. NUMBER
NOM. NOMINAL
N..S. NOT TO SCALE
KEY NAME FULL NAME
O.A. OVERALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OH OVERHEAD
O.H. OPPOSITE HAND
OPG. OPENING
PC PIECE
PCF POUNDS PER CUBIC FT
PL PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLT PLATE
PLF POUNDS PER LINEAR FT
PLUMB. PLUMBING
PLYWD PLYWOOD
POLY POLYETHYLENE
PR. PAIR
PSF POUNDS PER SQUARE FT
PSI POUNDS PER SQUARE IN
PFT PORCELAIN TILE
PT PAINT
PTD. PAINTED
Q.T. QUARRY TILE
R. RISER
RAD. RADIUS
RB RUBBER BASE
R.D. ROOF DRAIN
REF. REFERENCE
REINF. REINFORCING
REQ'D. REQUIRED
REV. REVISION
RFL RUBBER FLOOR
R.L. ROOF LEADER
RM. ROOM
RT. RESILIENT TILE
R.V. ROOF VENT
SCHED. SCHEDULE
SECT. SECTION
SF SQUARE FOOT
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATIONS
SQ. SQUARE
S.S. STAINLESS STEEL
ST STAIN
STD. STANDARD
STL. STEEL
STRUCT. STRUCTURAL
SUSP. SUSPENDED
T. TREAD
T/ TOP OF
T&B TOP AND BOTTOM
T/C. TOP CHOR
T/F TOP FLANGE
T/FTG TOP OF FOOTING
T.O. TOP OF
THK. THICK
THRU. THROUGH
TP. TOPPING
TRANS. TRANSVERSE
TS. TUBE STEE
T/S TOP OF SLAB
T/STL. TOP OF STEEL
TYP. TYPICAL
UNEX. UNEXCAVATED
UNO UNLESS NOTED OTHERWISE
VAR. VARIES
VB VINYL BASE
V.B. VAPOR BARRIER
VCT VINYL COMPOSITE TILE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
VTR VENT THRU ROOF
W WATER
W/ WITH
WB WOOD BASE
W.J. WATER CLOSET
WD WOOD
W.I. WROUGHT IRON
W.W.F. WELDED WIRE FABRIC
ABBREVIATIONS
A
0A
T.O. SLAB
0' - 0"
A101
SIM
A100 SIM
X
A100
Ref
A100
FD
RD
EXISTING WALL TO REMAIN, TYP.
EXISTING WALL TO BE REMOVED, TYP.
NEW STUD WALL CONSTRUCTION
NEW MASONRY WALL CONSTRUCTION
EXISTING DOOR
TO REMAIN, TYP.
EXISTING DOOR TO
BE REMOVED, TYP.
EXISTING FIXTURES
TO BE REMOVED
DEMOLITION TAG:
REFERENCE PLANS AND
GENERAL DEMOLITION NOTES
EQUIPMENT TAG:
REFERENCE PLANS AND
EQUIPMENT SCHEDULES
NOTE TAG:
SEE ASSOCIATED LEGEND
FLOOR DRAIN (FD)
ROOF DRAIN (RD)
X
X
WINDOW TAG:
REFERENCE WINDOW
SCHEDULE ON A900 FOR
SIZE AND DETAIL
ELEVATION TAG:
DRAWING NUMBER
(TOP NUMBER)
SHEET NUMBER
(BOTTOM NUMBER)
INTERIOR ELEVATION TAG:
DRAWING NUMBER (TOP NUMBER)
REFERENCE SPECIFIED SHEET
FOR DRAWING NUMBER
DOOR TAG:
REFERENCE DOOR
SCHEDULE ON A900 FOR
SIZE AND DETAIL
WALL TYPE TAG:
RATING
REFERENCE WALL TYPES
FOR WALL CONSTRUCTION
ELEVATION MARKER:
SPECIFIES THE VERTICAL
HEIGHT AT A GIVEN LOCATION
PLAN DETAIL TAG:
DRAWING NUMBER (TOP NUMBER)
REFERENCE SPECIFIED SHEET
FOR DRAWING (BOTTOM NUMBER)
SECTION DETAIL TAG:
DRAWING NUMBER (TOP NUMBER)
REFERENCE SPECIFIED SHEET FOR
DRAWING (BOTTOM NUMBER)
SYMBOLS
NOT IN CONTRACT
HATCH (N.I.C.)
ADD ALTERNATE. SEE
PLAN FOR TYPE.
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:28 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
Sheet List, Abbreviations and
Symbols
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G101
Drawing List Current Rev Sheet No. Sheet Name
ARCHITECTURAL
G100 Cover Sheet
G101 Sheet List, Abbreviations and Symbols
G102 General Notes
G103 General Notes
G200 Life Safety Plan
G201 Accessibility Details
G300 Wall Types
D101 Demolition Plans
D102 Enlarged Demolition Plans
D103 Reflected Ceiling Demolition Plans
A101 Floor Plans
A102 Lobby Floor Plan (Second Floor)
A103 Enlarged Plans
A104 Roof Plan and Details
A200 Building Elevations
A400 Stair Sections
A500 Exterior Details
A600 Details
A601 Details
A700 Interior Elevations
A701 Interior Elevations
A800 Reflected Ceiling Plans
A801 Second Floor Reflected Ceiling Plan
A802 Enlarged Reflected Ceiling Plan and Details
A900 Schedules
A901 Finish Schedule
A902 Finish Plan
A903 Finish Plan
FIRE PROTECTION
FP001 General Notes, Legend, and Details
FP301 Level 1 Fire Protection Plans
FP302 Lobby Level Fire Protection Plans
PLUMBING
P001 General Notes, Legend, and schedule
P301 Level 1 Plumbing Plans
P302 Lobby Level Plumbing Plans
MECHANICAL
M001 Legend, Abbreviations & General Notes
M301 Level 1 Mechanical Plans
M302 Lobby Level Mechanical Plans
M601 Equipment Schedules & Details
ELECTRICAL
E001 General Notes, Symbols, Abbreviations & Schedules
E301 First Floor Electrical Plans
E302 Lobby Level Electrical Removal Plans
E303 Lobby Level Electrical Plans
No. REVISION # DATE:
RFB-2025-25 - HVAC CONTRACT BID SET
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:28 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
General Notes
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G102
GENERAL DEMOLITION NOTES
1. SEE ALL DRAWINGS FOR ADDITIONAL NOTES AND SPECIFICATIONS.
2. OBJECTS SHOWN ON DEMOLITION PLANS WITH A "DASHED" LINE ARE TO BE REMOVED, AS A
"SYSTEM" IN THEIR ENTIRETY BACK TO SOUND STRUCTURE. COORDINATE WITH ALL GENERAL
DEMOLITION NOTES, KEYED DEMOLITION NOTES AND ALL ENGINEERING DRAWINGS.
3. THE CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION FOR PROJECT AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONFLICTING CONDITIONS WHICH WOULD INTERFERE WITH THE SATISFACTORY COMPLETION OF "THE WORK", PRIOR TO THE START OF DEMOLITION.
4. THE CONTRACTOR SHALL MAINTAIN AND PROTECT EXISTING UTILITIES TO REMAIN IN SERVICE
BEFORE PROCEEDING WITH DEMOLITION, PROVIDE BYPASS CONNECTIONS TO OTHER PARTS OF
THE BUILDING AS REQUIRED.
5. THE CONTRACTOR SHALL MAINTAIN LIFE SAFETY SERVICES AND FIRE EXTINGUISHERS
THROUGHOUT DEMOLITION PHASE AS REQUIRED.
6. THE CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IN WRITING OF ANY DISCREPANCIES
IN THE DRAWINGS REGARDING THE REMOVAL OF LOAD BEARING STRUCTURAL ELEMENTS NOT
DOCUMENTED OR DETAILED.
7. OWNER RESERVES THE RIGHT TO KEEP ANY ITEMS IDENTIFIED TO BE REMOVED OR SALVAGED.
CONTRACTOR IS TO COORDINATE IDENTIFIED ITEMS WITH THE OWNER AT THE START OF EACH
DEMOLITION PHASE. CAREFULLY SALVAGE ITEMS IDENTIFIED BY THE OWNER AND DELIVER THEM
TO LOCATION INDICATED BY OWNER.
8. THE CONTRACTOR SHALL CONDUCT ALL WORK IN CONFORMANCE WITH LANDLORD'S
REQUIREMENTS FOR DEMOLITION AND CONSTRUCTION.
9. THE CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REPLACE ANY DAMAGE IN THE
SURROUNDING AREAS CAUSED BY DEMOLITION AND CONSTRUCTION IN” AREA OF WORK”.
10. ALL EXISTING WALLS, COLUMNS, AND PERIMETER PIERS TO REMAIN IN "AREA OF WORK" ARE TO
BE PATCHED AND REPAIRED TO RECEIVE NEW FINISHES.
11. ALL CONTRACTORS ARE TO COORDINATE WITH BUILDING OWNER THE USE OF ELEVATORS AND
SERVICES, AND TO CONFORM TO ALL BUILDING REGULATIONS WITH REGARD TO DEMOLITION.
12. SEE ENGINEERING DRAWINGS AND NOTES FOR ADDITIONAL DEMOLITION REQUIREMENTS WHEN REFERRING TO HVAC, SPRINKLER, PLUMBING, ELECTRICAL, FIRE ALARM AND COMMUNICATION.
"SYSTEM" SHALL MEAN EVERYTHING NEEDED TO SUPPORT OR TO BE PART OF "THE SYSTEM"
INCLUDING BUT NOT LIMITED TO FASTENERS, POWER SUPPLY SYSTEMS, HVAC SYSTEMS,
PLUMBING SYSTEMS AND ADHESIVES TO THE FULLEST EXTENT POSSIBLE.
13. DEMOLITION CONTRACTOR TO CONSULT WITH BUILDING OWNER WHEN REMOVING CONDUITS
AND CABLES THAT MAY BE ACTIVE. IF SERVICE IS DISRUPTED CONTRACTOR T0 INCLUDE ALL
REPAIRS AS REQUIRED TO ANY CABLES AND CONDUITS.
14. ANY AND ALL ELECTRICAL/DATA AND TELEPHONE DEVICES, WIRING, CABLES, CONDUITS, ETC. TO BE REMOVED SHALL BE REVIEWED BY BUILDING OWNER, CLIENT CONSULTING ENGINEER AND ANY
OTHER CONSULTANT DEEMED NECESSARY PRIOR TO ANY WORK.
15. REMOVAL OF SUCH ELECTRICAL EQUIPMENT SHALL BE DONE IN SUCH A WAY AS TO ALLOW THE
OPERATIONS OF ADJACENT FLOORS TO CONTINUE WITHOUT INTERRUPTION OF ANY SERVICE
DURING DEMOLITION AND CONSTRUCTION. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS
NEEDED IN ORDER TO COMPLY WITH THIS REQUIREMENT.
16. ALL CONTRACTORS SHALL COORDINATE ALL REMOVALS WITH ALL OTHER TRADES.
17. CONTRACTOR SHALL PROTECT THE BUILDING INTERIOR FROM WEATHER AND WATER LEAKAGE
AND DAMAGE.
18. CONTRACTOR TO PROVIDE ADEQUATE BRACING AND SUPPORTS AS REQUIRED TO ENSURE THE
STRUCTURAL INTEGRITY OF THE EXISTING BUILDING TO REMAIN AS REQUIRED.
19. ALL MAJOR DEMOLITION AND NOISE CREATING WORK SHALL NOT OCCUR WITHIN THE HOURS OF 6 PM TO 7 AM DURING THE WEEK, UNLESS AGREED TO OTHERWISE IN WRITING BY CLIENT AND
BUILDING OWNER.
20. CAP ALL ABANDONED PIPING AND CONDUIT TO PREVENT POSSIBLE PASSAGEWAYS FOR
RODENTS, FIRE, OR GASES. COORDINATE WORK WITH ALL TRADES.
21. ALL ABANDONED POKE THROUGHS IN THE SLAB SHALL BE PATCH AND FILLED PER STANDARDS
AS STATED IN THE BUILDING RULES AND REGULATIONS, AND PER ALL LOCAL CODES.
22. FILL ALL UNUSED SLAB PENETRATIONS WITH PROPER STRUCTURAL AND FIRE RATED
REQUIREMENTS.
23. ALL LAYERS OF FLOOR FINISHES SCHEDULED FOR REMOVAL SHALL BE REMOVED DOWN TO
BASE SUB-FLOOR. ALL SUB-FLOORING SCHEDULED TO RECEIVE FLOORING SHALL BE STRIPPED OF
ALL SEALANTS, MASTICS, GREASE, AND PAINT. NOTIFY ARCHITECT PRIOR TO REMOVAL TO
ADDRESS BEST PRACTICE TO MOVE FORWARD.
24. REPAIR AND PATCH ALL SURFACES DAMAGED BY "THE WORK" TO MATCH AND TO BLEND INTO THE EXISTING ADJACENT SURFACE MATERIALS AND FINISHES, FLUSH AND SMOOTH. FOLLOWING
THE PROCEDURES OF THE PROJECT MANUAL.
25. PROVIDE BLOCKING OR SHORING AS REQUIRED TO SUPPORT BUILDING SYSTEMS PRIOR TO
DEMOLITION OF MASONRY OR NON - MASONRY BEARING WALLS OR SUPPORT STRUCTURES AS
REQUIRED.
26. THE CONTRACTOR TO REMOVE ANY AND ALL DOORS, FRAMES AND HARDWARE IN THE
EFFECTED AREAS. CONTRACTOR SHALL CONSULT WITH BUILDING OWNER FOR ANY
DOORS/FRAMES OR HARDWARE THAT THE OWNER MIGHT WANT TO REUSE.
27. THE CONTRACTOR SHALL MAINTAIN A SAFE, SECURE AND CLEAN SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS THROUGHOUT THE ENTIRETY OF "THE WORK", AT NO ADDITIONAL COST TO THE OWNER. AT A MINIMUM THE SITE IS TO BE SECURELY LOCKED WHEN
UNOCCUPIED AND BROOM SWEPT ON A DAILY BASIS AND SAFE OF LOOSE DEBRIS.
28. THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL DEBRIS AND
DISCARDED MATERIALS AND/OR EQUIPMENT AS INDICATED WITHIN THE SPACE. THE CONTRACTOR
MUST KEEP ALL DEBRIS REMOVED FROM SITE SEPARATE FROM THE BUILDING TRASH AND
PROVIDE DUMPSTERS THROUGH OUT CONSTRUCTION UNTIL PROJECT CLOSEOUT. LOCATE
DUMPSTERS IN THE LOCATION DESIGNATED BY THE OWNER. PROMPTLY REPLACE DUMPSTERS
WHEN THEY ARE FULL AND WHEN "THE WORK" HAS BEEN COMPLETED.
29. THE CONTRACTOR TO COORDINATE WITH THE BUILDING OWNER AS TO THE PROTECTION
AND/OR STORAGE OF ANY ITEMS TO BE SAVED FROM DEMOLITION.
30. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING ITEMS TO REMAIN (I.E. PLUMBING
FIXTURES, WINDOWS. CONVECTOR COVERS’ WALLS, CEILINGS, FLOORS, WINDOW TREATMENTS,
AND EXPOSED FINISHES, ETC.) THROUGHOUT THE COURSE OF THE JOB AND REPAIR DAMAGE AS
REQUIRED.
31. ASBESTOS NOTE: THE ABATEMENT OF ASBESTOS MATERIAL IS EXCLUDED FROM THIS PROJECT
AND WILL BE CONTRACTED SEPARATELY, IF REQUIRED. ANY ITEMS ENCOUNTERED IN THE
DEMOLITION SUSPECTED OF CONTAINING HAZARDOUS MATERIALS SHALL BE BROUGHT TO THE
OWNERS ATTENTION, FOR PROPER IDENTIFICATION AND DISPOSAL OF BY THE OWNERS
DESIGNATED FORCES.
32. LEAD PAINT NOTE: IF PAINT IS NOT TESTED, CONTRACTOR TO ASSUME MATERIAL IS HOT AND
THE CONTRACTOR SHALL FOLLOW LOCAL, STATED AND FEDERAL CODES ON RECOMMENDATIONS
FOR REMOVAL.
GENERAL STAIR NOTES
1. ALL STAIR AND HANDRAIL SYSTEMS SHALL BE DESIGNED TO COMPLY WITH ALL LOCAL, STATE, AND
FEDERAL CODES AND REGULATIONS. CONTRACTOR SHALL SUBMIT STAMPED AND SIGNED
DOCUMENTATION THAT THE AFOREMENTIONED SYSTEMS HAVE BEEN DESIGNED AND ENGINEERED
BY A LICENSED PROFESSIONAL IN THE STATE HAVING JURISIDICTION FOR THE PROJECT.
2. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF THE EXIT DOOR.
3. LANDINGS AT EGRESS STAIRS SHALL BE AT LEAST AS WIDE AS THE STAIRCASES THEY SERVE AND
MINIMUM OF 44”, AND A MAXIMUM OF 48” DEEP IN DIRECTION OF TRAVEL.
4. STAIRWAY WIDTH SHALL BE 44” MINIMUM, UNLESS NOTED OTHERWISE.
5. STAIR RISERS SHALL BE 4” MINIMUM AND 7” MAXIMUM IN HEIGHT.
6. TREADS SHALL BE 11” MINIMUM IN DEPTH.
7. STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE WITH MAXIMUM TOLERANCE
OF 3/8” DIFFERENCE BETWEEN LARGEST AND SMALLEST RESERS.
8. LEADING EDGE OF TREAD SHALL HAVE MAXIMUM, 9/16” BEVEL. RISERS SHALL BE SOLID (MAX 4” OPENING ALLOWED) AND VERTICAL OR SLOPED NOT MORE THAN 30 DEGREES. NOSINGS SHALL NOT
PROJECT MORE THAN 1 1/4” BEYOND TREAD BELOW.
9. PROVIDE 6'-8" MINIMUM CLEAR HEADROOM OVER TREAD OR LANDING, MEASURED VERTICALLY
FROM A LINE CONNECTING THE EDGE OF THE NOSINGS.
10. HANDRAILS SHALL BE PROVIDED ON EACH SIDE OF STAIRWAY.
11. HANDRAILS SHALL BE MOUNTED BETWEEN 34” AND 38” AS MEASURED ABOVE STAIR NOSINGS.
12. HANDRAILS WITH A CIRCULAR CROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST
1.25” AND NOT GREATER THAN 2".
13. HANDRAILS WITH A NON-CIRCULAR CROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 4"
MINIMUM AND NOT GREATER THAN 6 1/4". CROSS-SECTION SHALL NOT EXCEED 2 1/4".
14. HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL
POSTS OR OTHER OBSTRUCTIONS.
15. HANDRAILS SHALL EXTEND 12" MINIMUM AT TOP LANDING, AND EXTEND AT EQUAL TREAD DEPTH
AT BOTTOM OF STAIR RUNS.
16. HANDRAILS SHALL RETURN TO WALL, GUARD, OR LANDING SURFACE.
17. PROVIDE 1 1/2" CLEARANCE FROM ADJACENT WALLS TO FOR ALL HANDRAILS.
18. GUARDRAILS SHALL BE PROVIDED WHERE CHANGE IN FLOOR ELEVATION EXCEEDS 30” ABOVE FINISHED FLOOR OR GRADE. THE GUARDRAIL SHALL BE A MINIMUM OF 42" IN HEIGHT WITH OPENING
LIMITATIONS OF 4" MAXIMUM.
GENERAL ENERGY NOTES
1. ALL BUILDING ENVELOPE ELEMENTS THAT CONTAIN MATERIALS WHICH ARE CAPABLE OF
ABSORBING OR TAKING UP AND HOLDING MOISTURE SHALL BE PROTECTED BY A VAPOR BARRIER
RETARDER LOCATED ON THE WARM SIDE OF THE INSULATION.
2. INSULATION SHALL BE INSTALLED IN A MANNER THAT PROVIDES CONTINUITY OF INSULATION AT
PLATE LINES, SILL LINES, BAND JOISTS, AND CORNERS.
3. ALL JOINTS AND OPENINGS IN THE BUILDING ENVELOPE SYSTEM INCLUDING, BUT NOT LIMITED TO, THE PERIMETER AROUND WINDOWS AND DOOR FRAMES, BETWEEN WALLS AND ROOF/ CEILINGS, BETWEEN WALLS, FLOORS, AND FOUNDATIONS, BETWEEN WALL PANELS, AT UTILITY SERVICE
PENETRATIONS AND BETWEEN DISSIMILAR MATERIALS SHALL BE CAULKED, GASKETED,
WEATHERSTRIPPED, OR OTHERWISE SEALED.
4. ALL DOORS AND WINDOW "U" AND "R" VALUES AND INFILTRATION VALUES SHALL COMPLY WITH
THE CURRENT APPLICABLE STATE ENERGY CONSERVATION CONSTRUCTION CODE.
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:28 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
General Notes
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G103
GENERAL CEILING NOTES
1. WHEN PROVIDED, SEE ENGINEER'S DRAWINGS FOR ADDITIONAL NOTES AND GENERAL
INFORMATION. PROJECT "MECHANICAL", "ELECTRICAL", AND "PLUMBING" CONTRACT DOCUMENTS
AND NOTES SHALL SUPERSEDE AND HAVE PRECEDENCE OVER ALL APPLICABLE GENERAL NOTES
LISTED BELOW.
2. IF APPLICABLE, CONTRACTOR SHALL INSTALL LOCALLY APPROVED FIXTURES AND DEVICES ONLY.
3. ALL GYPSUM BOARD CEILINGS TO BE 5/8" AND SHALL BE TAPED, JOINT COMPOUNDED, SANDED
AND READY FOR PAINT, UNLESS NOTED OTHERWISE.
4. FULLY LAYOUT GRID, SOFFITS, AND OPENING PLACEMENT PRIOR TO THE START OF
CONSTRUCTION TO VERIFY DIMENSIONS ARE CONSISTENT WITH REQUIREMENTS IN THE
DOCUMENTS. REFER ANY DIMENSION INCONSISTENCES TO THE ARCHITECT FOR RESOLUTION
PRIOR TO THE START OF THE "THE WORK".
5. THE CONTRACTOR SHALL PROVIDE A COMPOSITE CEILING PLAN AND NECESSARY SHOP
DRAWINGS COORDINATING ALL TRADES, SHOWING THE LOCATION OF SUSPENSION MEMBERS,
LIGHT FIXTURES, EMERGENCY AND EXIT LIGHTING, HVAC DUCTS, DRAPERY POCKETS, FIRE
DAMPERS, ACCESS DOORS, SPRINKLERS AND PIPES, FASCIAS SOFFITS AND ALL OTHER ITEMS
PENETRATING OR ATTACHED TO THE CEILING.
6. ACCESS DOOR LOCATIONS TO BE REVIEWED IN THE FIELD PRIOR TO INSTALLATIONS, AND THEIR
LOCATIONS TO BE APPROVED BY THE ARCHITECT.
7. SEE REFLECTED CEILING PLAN FOR CEILING HEIGHTS. MAINTAIN CEILING HEIGHT THROUGHOUT, UNLESS NOTED OTHERWISE. NOTIFY ARCHITECT OF ANY DISCREPENCIES.
8. NO CEILING BREAKS WILL BE PERMITTED WITHIN A ROOM, UNLESS NOTED OTHERWISE.
9. IF CEILING GRID REQUIRES CUT TILES, ANY CUT TILES THAT ARE VISIBLE SHALL HAVE A FINISHED EDGE. CONTRACTOR MAY lNCLUDE EITHER PREFABRICATED TILES TO THAT DIMENSION AND/OR FINISH THE CUT EDGE OF TILE, TO MATCH CEILING TILE. SHOULD CUT EDGE BE EXPOSED, PROVIDE
PAINT TO MATCH CEILING TILE.
10. THE CONTRACTOR TO PROVIDE 3% ATTIC STOCK OF ALL CEILING TILES AT END OF PROJECT FOR
CLIENTS FUTURE USE.
11. IT IS REALIZED THAT AS CONSTRUCTION PROCEEDS AND AS PROJECTS NEARS COMPLETION, CEILING TILES OFTEN GET DAMAGED AND/OR DIRTY BY OTHER TRADES, THE CONTRACTOR AND
THEIR SUBCONTRACTORS ARE RESPONSIBLE TO REPLACE ANY AND ALL DAMAGED CEILING TILES
AND GRIDS AND/OR DRYWALL CEILINGS AND SOFFITS AT THEIR OWN COST.
12. AT END OF THE PROJECT, CONTRACTOR TO REALIGN ALL CEILING TILE AND GRIDS TO A SQUARE
AND LEVEL INSTALLATION.
13. INSTALL DIRECTIONAL ACOUSTICAL TILE WITH THE GRAIN IN ONE DIRECTION ONLY IN ANY SINGLE
SPACE.
1. FRAMING IS INDICATED DIAGRAMMATICALLY TYPICALLY IN THE DOCUMENTS. IT IS NOT THE INTENT
OF THE DOCUMENTS TO DELINEATE EVERY CONDITION OR MEMBER SIZE REQUIRED. THE
CONTRACTOR SHALL PROVIDE CONFIGURATIONS OF FRAMING AS REQUIRED BY THE DOCUMENTS
TO MAINTAIN THE SHAPE AND PROFILES OF SURFACES/MATERIALS REQUIRED, COORDINATE WITH
THE BUILDING STRUCTURE, AND SUPPORT THE REQUIRED LOADS.
2. TYPICAL PARTITION DETAILS DO NOT INDICATE EVERY COMBINATION OF MATERIALS REQUIRED.
SEE FLOOR PLAN INDICATIONS FOR PARTITION TYPES REQUIRED.
3. FORM RADIUS/CURVED WORK TO TRUE RADIUS WITHOUT SEGMENTATION, FACETING, BUCKLING, WARPING OR OTHERWISE ALTERING MEMBER DIMENSION OR APPEARANCE.
4. PROVIDE FRAMING LOCATED TO CLEAR CEILING/WALL MOUNTED DEVICES/EQUIPMENT.
COORDINATE FRAMING WITH DEVICE/EQUIPMENT REQUIREMENTS FOR CLEARANCES AND
SUPPORT. DEVICE SHALL TAKE PRECEDENCE PER MANUFACTURER'S RECOMMENDATION.
5. WHERE UTILITIES SUCH AS ELECTRICAL, TELE/DATA, PLUMBING AND THE LIKE CAN NOT BE
CONCEALED ABOVE CEILINGS, PROVIDE PUNCHED STUDS CONFIGURED TO PERMIT UTILITY
DISTRIBUTION WITHIN THE FRAMING. WHERE SUCH PUNCHES ARE PROVIDED THEY SHALL BE
ALIGNED WITHIN THE FRAMING TO PERMIT STRAIGHT UTILITY RUNS WITH MINIMAL OFFSETS.
COORDINATE WITH UTILITIES FOR SIZE, NUMBER AND LOCATIONS OF PUNCHES REQUIRED.
6. IN CASE OF CONFLICT OR DISCREPANCY, THE MORE RESTRICTIVE OR HIGHER QUALITY PARTITION
GOVERNS.
7. UNLESS NOTED OTHERWISE ON A SPECIFIC DETAIL, ALL METAL STUD FRAMING SHALL BE AS
FOLLOWS:
a. PROVIDE STUDS SIZES AS REQUIRED. STUD GAUGE SHALL BE DETERMINED BY ALLOWABLE
SPANS OF MEMBERS. NO WALL SHALL BE LESS THAN 20 GAUGE, UNLESS NOTED OTHERWISE.
b. UNLESS NOTED OTHERWISE, AND EXCEPT FOR FURRING ALL STUDS SHALL BE FULL HEIGHT
FROM FLOOR TO UNDERSIDE OF STRUCTURAL DECK ABOVE. STUDS SHALL BE CUT SHORT AT
HEAD TRACK/RUNNER TO ALLOW FOR DIFFERENTIAL LIVE LOAD DEFLECTION AS REQUIRED
HEREIN.
c. PROVIDE MINIMUM 20 GAUGE TRACKS/RUNNERS TO MATCH STUD SIZE, UNLESS NOTED OTHERWISE. AT HEAD, PROVIDE TRACKS/RUNNERS WITH VERTICAL LEGS OF SUFFICIENT HEIGHT
TO ACCOMMODATE DIFFERENTIAL LIVE LOAD DEFLECTION DIMENSION BETWEEN FLOORS.
d. FURRING SHALL EXTEND FROM FLOOR TO 6 INCHES ABOVE FINISHED CEILING, OR IF THERE IS
NO CEILING, TO STRUCTURAL DECK ABOVE.
e. ALL STUDS SHALL BE SPACED AS REQUIRED TO SUPPORT APPLIED FINISHES AND LOADS, BUT
NOT MORE THAN 16 INCHES O.C., UNLESS NOTED OTHERWISE.
f. PROVIDE FULL HEIGHT, UNPUNCHED, DOUBLE STUDS AT ALL JAMB AND HEAD CONDITIONS, COORDINATE WITH HSS HEAD SUPPORT.
8. FOR PARTITIONS WITHIN 15 FEET OF A COLUMN LINE, ALLOW FOR 1/2" LIVE LOAD DEFLECTION.
9. FOR PARTITIONS MORE THAN 15 FEET BUT LESS THAN 30 FEET FROM A COLUMN LINE, ALLOW FOR
3/4" LIVE LOAD DEFLECTION.
10. FOR PARTITIONS MORE THAN 30 FEET FROM A COLUMN LINE, ALLOW FOR 1" LIVE LOAD
DEFLECTION.
11. AT PARTITIONS EXTENDING OVER ROUGH OPENINGS (DOORS, SIDELIGHTS, BORROWED LIGHTS AND THE LIKE) IN EXCESS OF 6'-4" WIDE, PROVIDE LIGHT GAUGE METAL FRAMING OF DEPTH TO
MATCH ABUTTING PARTITIONS. PROVIDE CONCEALED DIAGONAL BRACING TO STRUCTURAL DECK
ABOVE AT 4'-0" O.C., CONFIGURED TO CLEAR STRUCTURAL, MECHANICAL AND ELECTRICAL
SYSTEMS.
12. AT ALL NON-FLOOR TO STRUCTURAL DECK PARTITIONS, PROVIDE DIAGONAL BRACING AT 4'-0"
O.C. EXTENDING FROM 12" ABOVE CEILING TO STRUCTURAL DECK ABOVE AT 12/12 SLOPE,
CONFIGURED TO CLEAR STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS.
13. PROVIDE BLOCKING IN PARTITIONS FOR ALL SUPPORTED/ATTACHED ITEMS/SYSTEMS.
14. PROVIDE WOOD BLOCKING IN WALLS FROM 2'-0" ABOVE FLOOR TO 4'-0" ABOVE FLOOR IN ALL
ANSI A117.1 COMPLIANT TOILET STALLS.
15. PROVIDE WOOD BLOCKING REQUIRED FOR WALL MOUNTED OWNER PROVIDED EQUIPMENT.
COORDINATE WITH OWNER FOR TYPE, SIZE AND LOCATION OF BLOCKING REQUIRED.
16. WHERE FRAMING CONNECTS TO CEMENTITIOUS FIREPROOFING COATED STRUCTURAL
STEEL/DECK, PROVIDE Z-FURRING FASTENED TO STRUCTURAL STEEL/DECK PRIOR TO
APPLICATION OF FIREPROOFING. Z-FURRING SHALL MATCH FIREPROOFING THICKNESS AND SHALL
BE CONFIGURED AS REQUIRED FOR PROPER SUPPORT/ATTACHMENT OF FRAMING. MINIMUM
GAUGE AND SPACING SHALL MATCH FRAMING REQUIREMENTS.
17. WHERE A SINGLE LAYER PARTITION TYPE ALIGNS WITH A MULTILAYER LAYER PARTITION TYPE, ADJUST FRAMING LOCATION TO ALIGN FINISHED FACES OF WALL BOARD ACROSS PARTITION
TYPES, UNLESS NOTED OTHERWISE.
18. CONTRACTOR TO CLEAN INSIDE OF ALL STUD CAVITIES BEFORE ENCLOSING WALL.
1. SEE PLANS FOR DEFINITION OF SCOPE OF FIRE-RESISTIVE PARTITIONS. FIRE PROOFING SHOWN IN
THE CONTRACT DOCUMENTS ARE DIAGRAMATIC IN NATURE. REFER TO DRAWING NOTES OR UL
DESIGN ASSEMBLY FOR ADDITIONAL INFORMATION. ALL FIRE-RESISTIVE PARTITIONS SHALL
CONFORM TO ALL LOCAL, STATE, AND FEDERAL CODES AS WELL AS WITH THE FOLLOWING NOTES
LISTED BELOW.
2. WHERE AN UNDERWRITERS LABORATORY OR OTHER TESTING AGENCY NUMBER IS INDICATED ON THE PARTITION TYPE DETAIL, THE PARTITION SHALL BE CONSTRUCTED IN STRICT ACCORDANCE
WITH THE TESTED ASSEMBLY.
3. OVERSIZE "CUT-OUTS" FOR ELECTRICAL DEVICE BOXES WILL NOT BE PERMITTED.
4. PROVIDE FIRESTOP SYSTEM AT ALL PENETRATIONS OF FIRE-RESISTIVE RATED PARTITIONS AND AT ALL OTHER LOCATIONS NECESSARY TO MAINTAIN THE FIRE RESISTIVE INTEGRITY OF THE ASSEMBLY.
5. PROVIDE FIRE RESISTIVE JOINT SYSTEM AT TOP OF ALL FIRE-RESISTIVE RATED PARTITIONS AT
DECK ABOVE AND AT CONTROL JOINTS.
6. WHERE FIRE RATED PARTITION INTERSECTS NON-RATED PARTITION, FIRE RATED PARTITION SHALL EXTEND THROUGH NON-RATED PARTITIONS. WHERE TWO FIRE RATED PARTITIONS INTERSECT, THE
GREATER OF THE FIRE RESISTANCE RATINGS SHALL EXTEND THROUGH LESSER FIRE RATED
PARTITION.
GENERAL METAL STUD FRAMING NOTES
GENERAL FIRE RESITIVE NOTES
14. ELECTRICAL:
a. WHEN PROVIDED, SEE ENGINEER’S DRAWINGS FOR ALL LIGHT FIXTURE CIRCUITING, EMERGENCY LIGHTING AND EXIT LIGHTING, SMOKE DETECTORS, STROBE LIGHTING, ALARM
SPEAKERS, SWITCHING AND RELATED WORK. LIGHT SWITCHES AND DIMMERS AS INDICATED ON
THE ARCHITECT'S PLANS ARE FOR LOCATION ONLY. CONTRACTOR SHALL VERIFY ALL LIGHT
FIXTURE WATTAGE (MAX.) AND PROVIDE PROPER NUMBER OF SWITCHES AT THAT LOCATION TO
THE CIRCUITING OF THOSE ITEMS.
b. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF LIGHTING
FIXTURES WITH THE SPECIFIED CEILING SYSTEM PRIOR TO ORDERING MATERIAL.
THE CONTRACTOR TO PROVIDE INITIAL LAMPING OF ALL LIGHT FIXTURES, USE MANUFACTURER’S
SPECIFIED LAMPS.
c. ALL LIGHT FIXTURES TO REMAIN OR BE REUSED, THE CONTRACTOR SHALL CLEAN, RELAMP, AND
REPLACE ALL FAULTY BALLASTS AND/OR BALLASTS NOT CONFORMING TO THE LATEST LOCAL
BUILDING CODE.
d. THE CONTRACTOR SHALL PROVIDE AND INSTALL SHALLOW DEPTH FIXTURES AS FIELD
CONDITIONS NECESSITATE, WITH THE ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST.
e. ALL LIGHT FIXTURES TO BE CENTERED IN CEILING GRID TILES, UNLESS NOTED OTHERWISE.
f. ALL THERMOSTATS, NEW AND EXISTING, TO BE INSTALLED AT 54” A.F.F. IN LOCATIONS APPROVED
BY THE ARCHITECT, UNLESS NOTED OTHERWISE.
g. THE CONTRACTOR SHALL REMOVE CEILING TILE(S) AS REQUIRED BY THE VOICE, DATA, A/V, SECURITY AND SIGNAL CABLE VENDOR OR OTHER TRADES AUTHORIZED FOR INSTALLATION BY
THE ARCHITECT. ALL CEILING TILES MUST BE REPLACED WHEN WORK IS COMPLETED.
15. MECHANICAL:
a. WHEN PROVIDED, SEE ENGINEER'S DRAWINGS FOR ALL CEILING DIFFUSERS, DUCTWORK
LAYOUTS, TRANSFER DUCTS, FUSIBLE LINKS, RETURN AIR GRILLS AND DAMPERS, ETC.
ARCHITECT’S DRAWINGS INDICATE DIFFUSERS FOR LOCATION ONLY. WHERE DISCREPANCIES
OCCUR BETWEEN ENGINEERING AND ARCHITECTURAL DRAWINGS REGARDING LOCATIONS,
ENGINEERING DRAWINGS SHALL GOVERN.
b. HVAC SUBCONTRACTOR TO SUBMIT A LAYOUT SHOP DRAWNG INDICATING ALL DIFFUSER
LOCATIONS AND DUCTWORK LAYOUTS TO ARCHITECT’S OFFICE FOR REVIEW AND APPROVAL
PRIOR TO FABRICATION OF ANY WORK.
c. THE CONTRACTOR TO THOROUGHLY CLEAN ALL EXISTING HVAC CEILING DIFFUSERS AND
RETURN AIR GILLES.
d. THE CONTRACTOR SHALL PROVIDE APPROPRIATE SIZED CUTOUT ABOVE CEILING WHERE PARTITION WALLS EXTEND TO SLAB ABOVE, AS REDUIRED FOR CIRCULATION OF RETURN AIR TO HVAC SYSTEM. FURNISH AND INSTALL FIRE DAMPERS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF RATED WALLS.
e. THE CONTRACTOR IS RESPONSIBLE TO BALANCE THE HVAC SYSTEM AFTER THE INSTALLATION IS COMPLETED AND SUBMIT A WRITTEN REPORT TO THE ARCHITECT’S AND ENGINEER’S OFFICE
FOR REVIEW AND APPROVAL.
16. FIRE PROTECTION:
a. WHEN PROVIDED, SEE ENGINEER'S DRAWINGS FOR THE LOCATION OF ALL SPRINKLER HEADS
AND RELATED WORK. ARCHITECTURAL DRAWINGS INDICATE SPRINKLER HEADS FOR LOCATION
ONLY. WHERE DISCREPANCIES OCCUR BETWEEN ARCHITECTURAL AND ENGINEERING
DRAWINGS REGARDING LOCATIONS, ENGINEERING DRAWINGS SHALL GOVERN.
b. THE CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH ALL, BUT NOT
LIMITED TO, HVAC EQUIPMENT, DUCTWORK, AND LIGHITNG.
c. SPRINKLER SUBCONTRACTOR TO SUBMIT A LAYOUT SHOP DRAWNG TO ARCHITECT’S OFFICE
FOR REVIEW AND APPROVAL OF ALL SPRINKLER HEAD LOCATIONS PRIOR TO FABRICATION OF
ANY WORK.
d. ALL SPRINKLER HEADS AT ACOUSTICAL TILE CEILINGS TO BE CONCEALED FLUSH TYPE WITH
PREFINISHED WHITE CAP TO MATCH CEILING, UNLESS NOTED OTHERWSE. SPRINKLER HEADS
SHALL BE CENTERED IN TILES, UNLESS NOTED OTHERWISE.
e. ALL SPINKLER HEADS AT GYPSUM BOARD CEILINGS TO BE CONCEALED FLUSH TYPE WITH
PREFINISHED CAP TO MACTH CEILING, UNLESS NOTED OTHERWISE.
1. UNLESS NOTED OTHERWISE, ALL WALLBOARD SHALL CONFORM TO THE FOLLOWING:
a. THICKNESS: 5/8", UNLESS NOTED OTHERWISE.
b. HEIGHT: ALL GYPSUM WALL BOARD SHALL EXTEND FULL HEIGHT OF PARTITION FROM SLAB TO
LIVE LOAD DEFLECTION DIMENSION FROM DECK.
c. BOARD TYPE: PROVIDE FIRE-RESISTIVE CORE WALLBOARD FOR ALL PARTITION TYPES EXCEPT
AS NOTED HEREIN:
• PROVIDE SHAFTWALL LINER BOARD AT ALL SHAFTWALL PARTITIONS ON THE SHAFT SIDE OF
THE PARTITION.
• PROVIDE HIGH-STRENGTH CEILING BOARD FOR ALL CEILING/SOFFIT BOARD.
• PROVIDE BACKER-BOARD AS THE FIRST LAYER (NOT EXPOSED) AT ALL MULTIPLE LAYER
APPLICATIONS.
• PROVIDE GYPSUM PLASTER BASE BOARD (BLUE BOARD) AS OUTER LAYER WHERE VENEER
PLASTER IS REQUIRED.
• PROVIDE MOISTURE RESISTANT BOARD AS OUTER LAYER ON PARTITIONS WHERE FINISH IS
PAINT IN TOILET ROOMS. DO NOT USE MOISTURE RESISTANT WALLBOARD ON CEILINGS.
• PROVIDE CEMENTITIOUS BACKERBOARD AS SUBSTRATE TO TILE.
GENERAL WALLBOARD NOTES
d. PROVIDE ALTERNATING ORIENTATION (VERTICAL/HORIZONTAL) OF WALLBOARD LAYERS IN
MULTI-LAYER PARTITION TYPES. STAGGER JOINTS IN LAYERS EACH WAY. SECURE EACH
LAYER TO FRAMING WITH SCREWS.
e. PROVIDE CONTROL JOINTS IN HORIZONTAL AND VERTICAL WALLBOARD SURFACES IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND AS NOTED
BELOW. SEE ELEVATIONS AND PLANS FOR JOINT LOCATIONS, OR, WHERE NOT INDICATED,
PROVIDE CONTROL JOINTS AS FOLLOWS:
• THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL OF CONTROL JOINT
LOCATIONS PRIOR TO INSTALLATION OF FRAMING.
• PROVIDE CONTROL JOINTS AT 30' MAXIMUM OC. PROVIDE CONTROL JOINTS WHERE
WALLBOARD ABUTS DISSIMILAR MATERIALS. CONTROL JOINTS AT DISSIMILAR MATERIALS
SHALL HAVE L-BEAD/EDGE TRIM AND SEALANT AS SPECIFIED.
• WHERE CONTROL JOINTS ARE REQUIRED IN A SURFACE THEY SHALL BE CONFIGURED TO
COORDINATE WITH THE BUILDING GEOMETRY/LAYOUT. PROVIDE ADDITIONAL CONTROL
JOINTS AT EACH END OF OPENINGS OVER 8' IN ANY DIMENSION.
• PROVIDE CONTROL JOINTS AT THE EDGE OF HORIZONTAL WALLBOARD WHERE IT ABUTS
VERTICAL WALLBOARD SURFACES BELOW.
• PROVIDE CONTROL JOINTS IN WALLBOARD WHERE CONTROL JOINTS ARE REQUIRED IN
FINISHES OR WHERE CONTROL JOINTS OCCUR IN SUBSTRATES.
• PROVIDE CONTROL JOINTS IN ACCORDANCE WITH THE REQUIREMENTS ABOVE AT
HORIZONTAL WALL BOARD CEILINGS/SOFFITS.
• PROVIDE CUSTOM FORMED RADIUS CONTROL JOINT TRIM AT RADIUS WORK. TRIM SHALL BE
EXTRUDED ALUMINUM.
f. NOTE: GYPSUM PLASTER BASE, MOISTURE RESISTANT, SHALL BE SUBSTITUTED FOR
FACE/OUTER LAYER OF WALLBOARD IN ACCORDANCE REQUIREMENTS HEREIN AND FINISH
SYSTEM(S) REQUIRED. SEE FINISH INFORMATION (PLANS/SCHEDULE) FOR ADDITIONAL
REQUIREMENTS.
g. PROVIDE WALLBOARD AT INTERIOR FACE OF ALL EXTERIOR WALL FRAMING EXPOSED TO
VIEW OR WHERE REQUIRED FOR ACOUSTICAL OR FIRE RESISTIVE REQUIREMENTS.
WALLBOARD SHALL CONFORM TO THE REQUIREMENTS HEREIN.
h. PROVIDE METAL TRIM SCREWED TO FRAMING AT ALL EXPOSED GYPSUM WALLBOARD
EDGES OR CORNERS EXCEPT WHERE CEMENTITIOUS BACKERBOARD OR CORNER GUARD IS
REQUIRED. WHERE RADIUS TRIM IS REQUIRED PROVIDE CUSTOM FORMED EXTRUDED
ALUMINUM TRIM. WHERE CEMENTITIOUS BACKBOARD IS REQUIRED PROVIDE PLASTIC TRIM.
NO PAPER OR COMBINATION PAPER/METAL OR PAPER / PLASTIC TRIM SHALL BE PERMITTED /
ACCEPTED.
i. PROVIDE LEVEL 1 FINISH AT SURFACES ABOVE CEILINGS, EXCEPT AT FIRE RESISTIVE RATED
PARTITIONS.
j. PROVIDE LEVEL 2 IN MECHANICAL AND ELECTRICAL TYPE ROOMS.
k. PROVIDE LEVEL 3 FINISH AT SURFACES OF FIRE RESISTANCE RATED PARTITIONS ABOVE
CEILINGS.
l. PROVIDE LEVEL 5 FINISH (PER Association of Wall and Ceiling Industries International-AWCI) AT ALL
EXPOSED GYPSUM WALLBOARD SURFACES TO RECEIVE DARK FINISH, AND AS SPECIFIED IN
THE CONTRACT DOCUMENTS. CONTRACTOR SHALL VERIFY LEVEL OF FINISH PRIOR TO
TAPING.
m. PROVIDE 4'x8'x3/4" FIRE-RESISTANT PLYWOOD BACK BOARDS BEHIND WALLBOARD TO LINE
ROOM IN TELECOM/DATA ROOMS, ELECTRICAL CLOSETS, IT ROOMS, AND IT SERVER ROOMS.
BACKBOARD SHALL BE MOUNTED VERTICALLY, 4" ABOVE FLOOR, TIGHT TO PARTITION FACE.
WHERE MOUNTED ON MASONRY PARTITION, PAINT FACE OF MASONRY WITH HIGH
PERFORMANCE INTERIOR COATING TO REDUCE MOISTURE TRANSMISSION. PAINT FACE AND
EDGES FLAT BLACK.
1. FOR ACOUSTICAL PERFORMANCE PARTITIONS, SEE ARCHITECTURAL FLOOR PLANS FOR
DEFINITION OF SCOPE OF ACOUSTICAL PERFORMANCE PARTITIONS. ALL ACOUSTICAL
PERFORMANCE PARTITIONS SHALL PROVIDE A STC RATING OF 50 AND SHALL CONFORM TO THE
FOLLOWING:
a. JOINTS IN WALLBOARD SHALL BE TAPED AND FINISHED AS REQUIRED, EVEN IN CONCEALED
LOCATIONS SUCH AS ABOVE SUSPENDED CEILINGS.
2. ELECTRICAL DEVICES BOXES FACING OPPOSITE SIDES OF THE PARTITION SHALL NOT BE
LOCATED BACK-TO-BACK OR BE LOCATED WITHIN THE SAME CAVITY BETWEEN STUDS.
3. PROVIDE ACOUSTICAL SEALANT AS FOLLOWS:
a. CONTINUOUSLY AROUND PENETRATIONS AT OUTER LAYER OF WALL BOARD AT EACH FACE.
b. CONTINUOUSLY BETWEEN CONCRETE FLOORS AND OUTER LAYER OF WALL BOARD AT EACH
FACE.
c. CONTINUOUSLY BETWEEN TOP OF OUTER LAYER OF WALLBOARD AND DECK ABOVE AT EACH
FACE.
d. CONTINUOUSLY UNDER BASE RUNNER TRACKS.
4. PROVIDE ACOUSTICAL INSULATION AS FOLLOWS:
a. BETWEEN STUDS FOR FULL DEPTH AND HEIGHT OF PARTITION.
b. AT TOP OF PARTITION TO FILL THE VOIDS AT METAL DECK INTERFACE. NOTE, IF PARTITION IS
ALSO A FIRE RESISTIVE RATED PARTITION FOLLOW NOTES HEREIN.
GENERAL ACOUSTICAL NOTES
GENERAL FOUNDATION NOTES
1. ULTIMATE STRENGTH DESIGN: CONCRETE (ASTM C94) F’c = 3,000 PSI, UNLESS NOTED
OTHERWISE.
2. DEFORMED REINFORCING STEEL SHALL BE ASTM A615 GRADE 60, AND WELDED WIRE MESH
SHALL BE ASTM A185, SUPPLIED IN FLAT SHEETS AND INSTALLED USING CHAIRS OR BOLSTERS.
3. MAXIMUM SLUMP SHALL BE 4 1/2 INCHES AND MINIMUM CEMENT CONTRACT SHALL BE 5 1/2 BAGS
PER CUBIC YARD. AIR ENTRAINMENT SHALL BE 4 TO 6 PERCENT, ADDITIVES CONTAINING
CHLORIDES ARE PROHIBITED.
4. UNLESS OTHERWISE DETAILED OR SPECIFIED, ALL REINFORCING SHALL HAVE GREATER OF A 40
DIAMETER LAP OR THAT REQUIRED BY ACI 318-89. PROVIDE CORNER BAR REINFORCING TO
MATCH SIZE AND SPACING OF WALL REINFORCING.
5. BEAR ALL FOOTINGS ON FIRM UNDISTURBED SOIL. DO NOT PLACE FOOTINGS IN WATER NOR ON
FROZEN GROUND.
6. PRIOR TO PLACING OF CONCRETE, ALL LOOSE MILL SCALE ALONG WITH ANY OTHER LOOSE OR
FOREIGN MATERIAL SHALL BE REMOVED FROM THE REINFORCING STEEL. ALL OTHER LOOSE OR
FOREIGN MATERIAL SHALL BE REMOVED FROM THE FORMS.
7. FORMS FOR FOOTINGS, WALLS, AND PIERS SHALL BE DESIGNED BY THE CONTRACTOR,
CONSTRUCTED STRAIGHT AND TRUE TO LINE AND BE ADEQUATELY BRACED TO SUPPORT
CONSTRUCTION LOADS.
8. CONCRETE IS TO BE PLACED CONTINUOUS BETWEEN CONSTRUCTION JOINTS WITHOUT COLD
JOINTS.
9. BEGIN CURING SLAB ON GRADE AS SOON AS FREE WATER HAS DISAPPEARED FROM EXPOSED
SURFACE. KEEP CONTINUOUSLY MOIST FOR FIVE (5) DAYS, OR APPLY CURING COMPOUND PER
MANUFACTURER'S INSTRUCTIONS. CUT CONTROL JOINTS AS SOON AS POSSIBLE IN EACH
DIRECTION AS REQUIRED TO REDUCE CRACKING.
10. TOLERANCES FOR FORMWORK, PLACING CONCRETE, CURING AND FINISHING SHALL BE IN
ACCORDANCE WITH CURRENT ACI RECOMMENDATIONS.
11. PROVISIONS SHALL BE MADE FOR THE WORK OF OTHER TRADES SUCH AS CAST IN PLACE
SLEEVES FOR ELECTRICAL, PLUMBING, MECHANICAL, ETC.
12. ALL FOUNDATIONS SHALL BE A MINIMUM OF 48" BELOW ADJACENT GRADES TO THE BOTTOM OF
THE FOOTING, THE SOIL HAS AN ASSUMED SOIL BEARING PRESSURE VALUE OF 2,500 PSF.
13. CONTRACTOR SHALL VERIFY SOIL BEARING PRESSURE PRIOR TO CONSTRUCTION.
14. FOUNDATION WALLS ARE TO BE COATED WITH ASPHALTIC BASED DAMPPROOFING, MAINTAIN
DAMPPROOFING BETWEEN 8" - 12" BELOW GRADE.
15. ALL CONTROL AND CONSTRUCTION JOINTS, AND CONCRETE SLAB PERIMETER JOINTS SHALL
BE CAULKED.
Additional Code ProvisionsLife Safety Plan Legend
EDUCATIONAL SURFACE MOUNT FIRE
EXTINGUISHER
SEMI-RECESSED FIRE
EXTINGUISHER CABINET
PATH OF TRAVEL
ACCESSIBLE FEATURE
TRAVEL DISTANCE START
POINT
FE
FE
1 HOUR RATED WALL
MISCELLANEOUS
STORAGE / MECHANICAL AREAS (300 SF)
1. MARKING AND INDENTIFICATION: FIRE-RESISTANCE RATED WALLS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
SIGNS OR STENCILING. MARKING SHALL COMPLY WITH THE FOLLOWING:
1.1. SHALL BE LOCATED IN ALL ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES.
1.2. BE REPEATED AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION
1.3. INCLUDE LETTERING NOT LESS THAN 0.5 INCH IN HEIGHT, INCORPORATING THE SUGGESTED WORDING: "FIRE BARRIER - PROTECT
ALL OPENING"
2. THROUGH-PENETRATION FIRESTOP SYSTEM REQUIREMENTS: THROUGH-PENETRATIONS OF
FIRE-RESISTANCE RATED WALL ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED
THROUGH-PENETRATION FIRESTOP SYSTEM, WITH AN F RATING OF NOT LESS THAN 1-HOUR,
INSTALLED AND TESTED IN ACCORDANCE WITH ASTM E 814-2006 or UL 1476-2003, WITH A
MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER.
3. THERMAL AND SOUND INSULATING MATERIALS: ALL INSULATING MATERIALS SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE
THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84-2007 or UL
723-2003.
4. FIRE EXTINGUISHERS SHALL BE MOUNTED 42" MAXIMUM A.F.F. SEE LIFE SAFETY PLAN FOR EXTEINGUISHER LOCATIONS
5. REFERENCE LIFE SAFETY PLAN FOR KNOX BOX LOCATION
6. COMBUSTIBLE MATERIAL SHALL BE PERMITTED IN BUILDINGS OF TYPE I OR TYPE II CONSTRUCTION PER 2020 NYSBC 603.1:
• MILLWORK SUCH AS DOOR,S DOOR FRAMES, WINDOW SASHES AND FRAMES
• INTERIOR WALL AND CEILING FINISHES INSTALLED PER IBC SECTIONS 801 & 803
• TRIM INSTALLED IN ACCORDANCE WITH IBC 802
• BLOCKING SUCH AS HANDRAILS, MILLWORK AND CABINETS
• SPRAYED FIRE RESISTIVE MATERIALS
7. PLYWOOD SUBSTRATES SHALL BE FIRE TREATED.
UNOCCUPIED AREA
ADA GENDER NEUTRAL TOILET ROOM
GENDER NEUTRAL TOILET ROOM
CORRIDOR
VEST.
LOBBY
FACULTY OFFICE
FACULTY OFFICE
MECHATRONICS LAB
STAIR
CORRIDOR
ELEVATOR
STORAGE
CORRIDOR
N.I.C.
FE
FE
FE
ENTRANCE
EXIST.
FE
AED
KNOX
BOX
EXIT 1:
ALLOWABLE: 250' - 0"
PROVIDED: 63' - 0"
EXIT 2:
ALLOWABLE: 250' - 0"
PROVIDED: 58' - 0"
FACULTY OFFICE
EXIT 3:
ALLOWABLE: 250' - 0"
PROVIDED: 49' - 2"
EXIT 4:
ALLOWABLE: 250' - 0"
PROVIDED: 104' - 0"
EXIT 5:
ALLOWABLE: 250' - 0"
PROVIDED: 91' - 10"
DN
DN
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:29 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
Life Safety Plan
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G200TRUE
NORTH
PROJECT
NORTH
SCALE:G200 1/8" = 1'-0"
1 Second Floor (Ground) Life Safety Plan
42" MIN. X<48" 42" MIN.
" M
IN
180 DEGREE TURN
36" MIN. X<48" 36" MIN.
" M
IN
180 DEGREE TURN EXCEPTION T-SHAPED SPACE FOR 180° TURNS
" M
IN
.60 " M
IN
12" MIN. 36" MIN. 12" MIN.
" M
IN
SPACE NEEDED FOR U-TURN
" M
IN
" M
IN
42 7/8" 6"
DIMENSIONS OF ADULT SIZED WHEELCHAIR
48"
CLEAR FLOOR SPACEWHEELCHAIR TURNING SPACE
32" MIN.
36" MIN.
MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR
32" MIN.
" M
AX
MAXIMUM DOORWAY DEPTHSPACE ALLOWANCES AND REACH RANGE
TO
2"
DOOR
FLOOR
U-SHAPED
HANDLE
1/2" MAX.
HANDICAP DOOR HARDWARE
WALL MOUNTED SIGNAGE TO BE LOCATED ON
LATCH SIDE OF DOOR, CLEAR OF
DOOR-SWING. MOUNT AT 60" TO
CENTERLINE OF SIGN SIGN FROM FLOOR.
CORRESPONDING
GRADE II BRAIL
HEIGHT OF LETTERING
5/8" MIN. TO 2" MAX
UPPERCASE CHARACTERS
LETTERING RAISED 1/32"
NOTE:
G.C. TO PROVIDE ALL ADA AND/OR RESTROOM
SIGNAGE, AND ANY STOREFRONT ADDRESS
NUMBERS AS REQUIRED BY LANDLORD AND
AUTHORITIES HAVING JURISDICTION. TYP.
HANDICAP SIGNAGE MOUNTING
" M
IN
CLEAR FLOOR
SPACE
48" MIN.
MAX.
17"
19" MAX.
LAVATORY CLEAR FLOOR SPACE
ACCESSIBILITY DETAILS
CLEAR FLOOR SPACE
CLEAR FLOOR SPACE
M
IN
HO
LD
CLEAR SPACE FOR FIXTURES
56" MIN.
HO
LD
"-1
8"
" M
IN
" M
IN
4" MAX.
4" M
AX
NOTE:
59" DEPTH REQUIRED FOR FLOOR
MOUNTED TOILETS PER ICC/ANSI
A117.1-2009 FIGURE 604.8.2 (b)
WALL MOUNTED WATER CLOSET
42" MIN. CLEAR
OBSTRUCTIONS
48"
" M
AX
" M
AX
" M
IN
NOTE:
* IF BOTH CLOSER AND LATCH ARE PROVIDED
** 48" MINIMUM IF BOTH CLOSER AND LATCH PROVIDED
SIDE APPROACH - SWINGING DOOR
" M
IN
24" MIN.
NOTE:
*48" MINIMUM IF CLOSER IS PROVIDED
LEFT SIDE APPROACH - SWINGING DOOR
PUSH SIDE
NOTE:
*54" MINIMUM IF CLOSER IS PROVIDED
LATCH SIDE APPROACH - SWINGING DOOR
PULL SIDE
24" MIN.
" M
IN
24" PREFERED
18" MIN.
PULL SIDE
FRONT APPROACH - SWINGING DOOR
" M
IN
MIN.
12" *
NOTE:
* IF DOOR HAS A CLOSER AND A LATCH
PUSH SIDE
FRONT APPROACH - SWINGING DOOR
Y
X
NOTE:
X = 36" MIN. IF Y = 60"
X = 42" MIN. IF Y = 54"
PULL SIDE
HINGE SIDE APPROACH - SWINGING DOOR
" M
IN
MIN.
12" *
MIN.
22"
404.2.6 Door Hardware. Handles, pulls, latches locks and other operable parts shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching or twisting of the wrist to operate. Operable parts of such hardwall shall be 34” Minimum and 48” maximum above the floor. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Exception: Locks used only for security purposes and not used for normal operation shall not be required to comply with Section 404.2.6
404.2.7 Closing Speed. Door closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to an open position of 12 degrees shall be 5 seconds minimum.
404.2.8 Door-Opening Force.. Fire doors shall have the minimum opening force allowable by the appropriated administrative authority. The force for pushing or pulling open doors other than fire doors shall be as follows:
1) Interior hinged door: 5.0 pounds (22.2N) Maximum
2) Sliding or Folding door: 5.0 pounds (22.2N) Maximum
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.
SEE 404, ANSI A117.1, 404.2.6 THRU 404.2.8
9"
2'
3"
6"
2'
2' - 10" 1' - 0"
ADA TUB UNIT - SIDE
PAPER
TOWEL &
TRASH
DRINKING
FOUNTAIN
T.
O.
SP
OU
T
3"
R
AN
GE
T.
O.
SP
OU
T
3'
0" M
AX
" M
AX
3'
8"
ACCESSORIES
3'
6"
16" MIN.
PER ELEVATION
" M
IN
PE
R
EL
EV
AT
IO
N 3'
4"
2'
2'
LAVATORY
1'
0" 4'
2' - 0"
HA
ND
IC
AP
1'
5" ST
AN
DA
RD
2'
0"
1 1 1
URINAL
HA
ND
IC
AP
1'
5"
1'
0" 4'
1'
3"
6" 3' - 0"
CO
AT
H
OO
K
- I
NS
ID
E
PA
RT
IT
IO
N
5'
0"
6 7
11 11 11
HANDICAP TOILET STANDARD TOILET
1' - 0" 3' - 6"
M
IN
MAX.
24"
2'
6" 1'
6"3' - 3"
HANDICAP TOILET
6 7
ADA TUB UNIT - FRONT
2'
6"
2'
1'
6"
4"
12" 12"
M
IN
" M
IN
36" MIN. 36" MIN.
" M
IN
BACK WALL
CONTROL WALL
SEAT WALL
STALL AND GRAB BARS
NOTE:
G.C. TO PROVIDE SOLID BLOCKING FOR
ALL WALL MOUNTED ACCESSORIES AND
FIXTURES
42" MAX.
SEAT MOUNTED AT 17"
MIN. / 19" MAX.
" M
IN
MIN.
14"-15" 1 1/4"3" MAX.
1/
4"15 "-1
6"
FOLDING SEAT
COMPLIES WITH ANSI
A117.1 SECTION 610
" M
AX
15" MAX. 15" MAX.
CONTROL
WALL
CONTROLS, HANDSHOWER, GRAB BAR LOCATIONS
6"
3" -6
" M
IN
4"
32" MIN.
" M
IN
CONTROLS AND
HAND SHOWER
LOCATIONS
1 1/4" - 1 1/2" 1 1/2"
GRAB BAR DETAIL
PLOT DATE:
C o p y r ig h t
C
A
R C
H
IT
E C
T U
R E
P
C
T h e m a t e r ia l a n d i d e a s c o n t a in e d i n t h is d o c u m e n t a r e c o n f id e n t ia l a n d a r e t h e p r o p r ie t a r y p r o p e r t y o f C
A
R C
H
IT
E C
T U
R E
P
C
T h e s e m a t e r ia ls a n d i d e a s s h a ll n o t b e r e le a s e d o r o t h e r w is e m a d e a v a il a b le t o a n y t h ir d p a r t y o r r e p r o d u c e d i n w h o le o r i n p a r t w it h o u t t h e e x p r e s s w r it t e n c o n s e n t o f C
A
R C
H
IT
E C
T U
R E
P
C
Job No:
Scale:
Date:
Sheet Title:
Drawn By:
Project:
Stamp:
As Noted www.C2-DesignGroup.com
24 Airport Road Schenectady, ny 12302
Sheet Number:
518.320.8250
Design Group
11/5/2024 7:00:30 PM
78 Washington Ave Schenectady, NY 12305
Bid Set | RFB 2024-65
C2 Architecture
11/05/2024
Interior Renovation to:
Owner:
SUNY Schenectady 78 Washnigton Ave Schenectady, NY 12305
Architect:
C2 Architecture 24 Airport Road Schenectady, NY 12302
MEP Engineer:
Engineered Solutions 646 Plank Rd Clifton Park, NY 12065
Accessibility Details
SUNY SCCC CST Building Lobby and Bathroom
Renovations
G201
TOILET PARTITIONS
GRAB BARS
GLASS MIRROR (SECURED TO WALL)
HAND DRYER
PAPER TOWEL DISPENSER
TOILET PAPER HOLDER/DISPENSER
SANITARY NAPKIN DISPOSAL (WOMENS ONLY)
WALL MOUNTED SOAP DISPENSER
HAND SHOWER
DRINKING FOUNTAIN
TOILET
WALL MOUNTED URINAL
WALL MOUNTED SINK
Toilet Accessories Legend
14 FOLDING SEAT (WHERE APPLICABLE)
1. WHEN STUD FRAMING IS STOPPED, BRACE WALLS AS REQUIRED.
2. TOP TRACKS OF ALL FLOOR TO STRUCTURE WALLS TO BE SLOTTED
FOR DEFLECTION.
3. PROVIDE MOSITURE RESISTANT GWB AT ALL WET LOCATIONS.
4. PROVIDE HORIZONTAL METAL STUD BRACING AT 48" O.C.
VERTICAL AT ALL WALLS.
5. IN WALLS WITH GWB FINISH OVERR 30' IN LENGTH, PROVIDE
CONTROL JOINTS IN WALL. COORDINATE FRAMING AS REQUIRED.
REVIEW CONTROL JOINT LOCATIONS WITH ARCHITECT.
6. PROVIDE ADDITIONAL LAYER OR LAYERS OF GWB AS REQUIRED
FOR PARTITIONS WHERE ADJACENT LAYERS NEED TO BE ALIGNED
OR FLUSH.
7. IF MULTIPLE LAYERS OF GWB ARE TO BE APPLIED, STAGGER JOINTS
AT LEAST 16" RELATIVE TO ONE ANOTHER.
8. STUD GAUGE SHALL BE DETERMINED BY ALLOWABLE SPANS OF
MEMBERS. NO WALL SHALL BE LESS THAN 20 GAUGE (UNLESS
NOTED OTHERWISE).
0A PARTITION TYPE: 0A 0 HR
N/AUL DESIGN NO.STC RATING
0B PARTITION TYPE: 0B 0 HR
N/AUL DESIGN NO.STC RATING
OC PARTITION TYPE: 0C 0 HR
N/AUL DESIGN NO.STC RATING
0D PARTITION TYPE: 0D 0 HR
N/AUL DESIGN NO.STC RATING
0F PARTITION TYPE: 0F 0 HR
N/AUL DESIGN NO.STC RATING
GENERAL PARTITION TYPE NOTES
NOTES:
1. REFERENCE CEILING PLANS FOR CEILING TYPE AND HEIGHT
2. WHERE NO CEILING EXISTS, EXTEND GWB TO UNDERSIDE OF DECK
NOTES:
1. REFERENCE CEILING PLANS FOR CEILING TYPE AND HEIGHT
2. WHERE NO CEILING EXISTS, EXTEND GWB TO UNDERSIDE OF DECK
0E PARTITION TYPE: 0E 0 HR
N/AUL DESIGN NO.STC RATING TBDTBDTBDTBDTBDTBD
STRUCTURE ABOVE
EXISTING STRUCTURE
(1) LAYER 5/8" GWB
7/8" METAL HAT CHANNEL AT
16" O.C. SECURED TO EXISTING
MASONRY WALL
STRUCTURE ABOVE
EXISTING CMU WALL
(1) LAYER 5/8" GWB
LAMINATED TO
EXISTING CMU WALL
STRUCTURE ABOVE
EXISTING CMU WALL
CEILING FINISH, REFERENCE
CEILING PLAN FOR CEILING
TYPE AND HEIGHT.
1 5/8" METAL STUD FRAMING
AT 16" O.C. (20GA).
(1) LAYER 5/8" GWB. EXTEND
GWB TO UNDERSIDE OF DECK.
STRUCTURE ABOVE
4 7/8"
3 5/8" METAL STUD FRAMING AT
16" O.C. (20GA).
(1) LAYER 5/8" GWB EACH
SIDE. EXTEND GWB TO
UNDERSIDE OF DECK.
METAL CHANNEL RUNNER AT TOP
AND BOTTOM. - SECURE TO DECK
TOP AND BOTTOM.
STRUCTURE ABOVE
EXISTING STRUCTURE
CEILING FINISH, REFERENCE
CEILING PLAN FOR CEILING
TYPE AND HEIGHT.
3 5/8" METAL STUD FRAMING
AT 16" O.C. (20GA).
(1) LAYER 5/8" GWB. EXTEND
GWB TO UNDERSIDE OF DECK.
STRUCTURE ABOVE
4 7/8"
3 5/8" METAL STUD FRAMING
AT 16" O.C. (20GA).
METAL CHANNEL RUNNER AT TOP
AND BOTTOM. - SECURE TO DECK
TOP AND BOTTOM.
(1) LAYER 5/8" BACKER BOARD,
PARTIAL HEIGHT.
WALL TILE, PARTIAL HEIGHT
0A PARTITION TYPE: 0G 0 HR
N/AUL DESIGN NO.STC RATING
0B PARTITION TYPE: 0H 0 HR
N/AUL DESIGN NO.STC RATING
OC PARTITION TYPE: 0I 0 HR
N/AUL DESIGN NO.STC RATING
0D PARTITION TYPE: 0J…
This is the start of the file's text. The full file is on GovTribe.