Revised Addednu 1.pdf
PDF 3 MB Posted
- Attached to
- Marvin Ridge High School Roof Renovation Project
- Solicitation number
- 248-6-97648063
- Issued by
- Union County, Raleigh City, North Carolina
About this file
This document is an Addendum No. 1 (revised) to the bid documents for the Marvin Ridge High School Roof Renovation Project issued by Union County Public Schools in Waxhaw, North Carolina, dated May 14, 2026, with Bid Number 6-97648063. The addendum addresses inquiries from prospective bidders regarding block sealant specifications and provides detailed technical requirements for the split face block sealant work. The addendum includes Section 071916 specifications for a water-repellent sealer to be applied to interior and exterior concrete surfaces, establishing manufacturer qualifications requiring a minimum of 15 years of manufacturing experience and ISO 9001:2015 certification, and applicator qualifications requiring a minimum of 5 years of experience on similar projects with successful completion of at least 5 comparable projects. A field sample mockup of at least 100 square feet must be installed and approved by the owner/engineer prior to commencement of full application work. The specified product is Sikagard-H 1000 by Sika, a 100 percent silane-based, clear, breathable sealer that penetrates concrete surfaces to seal out water, chlorides, and acids while preventing freeze-thaw cycle damage. Application requires surface preparation via pressure washing at 1,500 PSI minimum with a flow rate of 4 GPM or greater, utilizing environmentally friendly chemical cleaning agents, with application restricted to temperatures between 40 degrees Fahrenheit and 95 degrees Fahrenheit and prohibited during rain or within 4 hours of anticipated precipitation.
The addendum includes detailed elevations and construction detail plans (C-1 through C-5) showing split face block locations on the east, north, south, and west building elevations, with notes specifying pressure washing requirements for concrete and EIFS walls, EIFS repair procedures, and sealant application over identified split face block surfaces after pressure washing. The material specifications require a minimum VOC content of 3.05 lbs per gallon (less water and exempt solvents) and compliance with Alberta DOT Type 1c requirements, including specific performance standards for water repellency, penetration depth averaging 0.35 inches, waterproofing repellency of 83.5 percent after heavy abrasion, and water weight gain reductions of 85 to 90 percent depending on coverage rate. All other terms, conditions, specifications, and requirements of the original bid documents remain unchanged by this addendum.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Drawings Binder Marvin Ridge Addendum #2 to scale.pdf | ||
| Addendum # 1 Bid 6-97648063.pdf | ||
| Marvin Ridge Bid 6-97648063 Final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM TO BID DOCUMENTS
Addendum No. 1 - Revised
Project Name Marvin Ridge High School Roof Renovation
Bid Number 6-97648063
Date 5/14/26
I. PURPOSE OF ADDENDUM
The purpose of this addendum is to address inquiries received from prospective bidders, block sealant specifications and drawings.
All other terms, conditions, specifications, and requirements of the original bid documents remain unchanged.
II. ATTACHMENT
Questions and Answers
Block Sealant
Drawings
| �� | � |
| � ��� | |
| � | � �� ����� |
������� �� �� �� �� 0))
+%#10��
������ )* 2 3
������ )22*$- ��
0� � ������� 4��� 0 ( �
• 5�� ��1���� �
��1���� �
3� �
| �� | � |
| � ��� | |
| � | � �� ����� |
�"1
*� 6�
����1"�
• 4�! ������� "�
7� &������ 10%#1*�
-%&10! $%&1 ��� %8�)-�
2� ���
• 5��' ���� ���� ���
�� �������� 5��
$+9-3 ��� ����� ��� ���1��� ���������
)� $%&1$ �
• 5�� ��1���� �
��1���� �
2025 Marvin Ridge High School Roof Replacement Project Section 071916 � Split Face Block Sealant
Union County Public County Schools Page 1 of 3
SECTION 07 19 16
SPLIT FACE BLOCK SEALANT
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Water repellent sealer for interior or exterior concrete surfaces as scheduled.
1.2 SUBMITTALS
A. Product Data: Submit manufacturer's technical data sheets.
B. Quality Control Submittals:
1. Provide protection plan of surrounding areas and non-work surfaces.
1.3 QUALITY ASSURANCE
A. Qualifications:
1. Manufacturer Qualifications: Company with minimum 15 years of experience in manufacturing of specified products.
2. Manufacturer Qualifications: Company shall be ISO 9001:2015 Certified.
3. Applicator Qualifications: Company with minimum of 5 years� experience in application of specified products on projects of similar size and scope and is acceptable to product manufacturer.
a. Successful completion of a minimum of 5 projects of similar size and complexity to specified work.
B. Field Sample:
1. Install field sample at project site or other pre-selected area, as directed by owner/engineer.
a. Provide mockup of at least 100 sf (9.3 m2) to include surface preparation, sealant joint, and juncture details and allow for evaluation of repellent performance and finish.
b. Conduct absorption test on cured field sample. Adjust application until required repellent performance is achieved.
c. Apply material in accordance with manufacturer�s written application instructions.
2. Field sample will be standard for judging workmanship on remainder of project.
3. Maintain field sample during construction for workmanship comparison.
4. Do not alter, move, or destroy field sample until work is completed and approved by architect/engineer.
2025 Marvin Ridge High School Roof Replacement Project Section 071916 � Split Face Block Sealant
Union County Public County Schools Page 2 of 3
5. Obtain owner/engineer written approval of field sample before start of material application, including approval of aesthetics, color, texture, and appearance.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Comply with manufacturer�s ordering instructions and lead-time requirements to avoid construction delays.
B. Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.
C. Store in unopened containers in clean, dry area between 35 degrees F (2 degrees C) and 110 degrees F (43 degrees C).
1.5 PROJECT CONDITIONS
A. Environmental Requirements:
1. Minimum application temperature is 20 degrees F (minus 7 degrees C) and rising.
2. Do not apply in rain or when rain is expected within 4 hours. Do not apply above 95 degrees F (35 degrees C) or below 40 degrees F (4 degrees C) or when temperatures are expected to fall below 20 degrees F (minus 7 degrees C) within 12 hours.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Clear, breathable, high-performance, 100 percent silane sealer for protecting new and existing concrete surfaces. Penetrates deeply, sealing out water, chloride ions, and acids, preventing damage from freeze/thaw cycles.
1. Bases of Design: Sikagard-H 1000 by Sika.
B. Water repellant sealer complies with the following requirements:
1. Compliance: Alberta DOT, Type 1c.
2. Silane Content by Weight: 100 percent.
3. Penetration, average depth, depending upon substrate: 0.35 inch (9 mm).
4. Surface Appearance after Application: Unchanged.
5. Flash Point, SETA: Greater than 165 degrees F (62.7 degrees C).
6. Waterproofing Repellency after Heavy Abrasion, Alberta DOT penetrating sealer, Type
1c, 0.35 w/c ratio: 83.5 percent.
7. Water Weight Gain, NCHRP 244 Series II Cube Test:
a. 250 sf per gal (6.1 m2/L): 90 percent reduction.
b. 400 sf per gal (9.8 m2/L): 85 percent reduction.
8. Absorbed Chloride, NCHRP 244 Series II Cube Test:
a. 250 sf per gal (6.1 m2/L): 96 percent reduction.
b. 400 sf per gal (9.8 m2/L): 87 percent reduction.
2025 Marvin Ridge High School Roof Replacement Project Section 071916 � Split Face Block Sealant
Union County Public County Schools Page 3 of 3
9. Absorbed Chloride, NCHRP 244 Series IV Southern Climate: 98 percent reduction.
10. VOC Content:
a. 3.05 lbs per gal (365 g/L), less water and exempt solvents.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Contractor shall verify the brick is acceptable to receive sealant.
3.2 SURFACE PREPARATION
A. Prepare surfaces in accordance with manufacturer�s instructions.
B. Sealant shall be applied after pressure washing surface.
C. Verify substrate has properly cured. Surfaces shall be clean and structurally sound. Remove dust, dirt, oil, grease, chemical films, coatings and other contaminants before application.
D. Do not apply sealer if standing water is visible on surface to be treated.
3.3 APPLICATION
A. Apply sealer in accordance with manufacturer�s instructions.
B. Stir material thoroughly before and during application.
C. Apply even distribution of sealer at the rate required by the manufacturer.
D. Apply one coat of sealant.
3.4 PROTECTION
A. Protect sealer from damage during construction.
END OF SECTION 07 19 16
HS
HS
HS
HS
HS
HS
U N
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
DETAIL PLAN
DP03
DP-03
DETAIL PLAN
SCALE:
16 " = 1'-0"
KEY PLAN
1/DP03
R-2
R-2
R-2
R-2
R-3
R-2
R-2
R-2
R-2
R-3
R-3
R-2
R-2
R-2
R-2
R-2
R-2
R-2
R-2
R-1
R-1
R-3
R-3
R-3
R-3
R-2
R-1
R-1
R-3
R-3
R-1
R-1
R-2
R-2
R-2
R-2
R-2
R-2
DP-03
DETAIL PLAN
SCALE:
32" = 1'-0"
2/DP03
R-2
R-2
R-1
R-2
R-3
R-3
R-2 5
R-2
R-2
R-3
R-3
R-2
R-3
R-3
R-3
R-3
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
R-4
ROOF AREA
01.09
R-1
ROOF AREA
01.12
ROOF AREA
02.01
ROOF AREA
02.02
ROOF AREA
01.10
R-1
ROOF AREA
01.11
R-1
ROOF AREA
01.08
R-1
ROOF AREA
04.01
R-1
SEE 7/R-4
SEE 9/R-4
SEE 7/R-4
SEE 7/R-4
R-5
SEE NOTE
#12/C1
FOR CONSTRUCTION
NOTE: THE METAL ROOF WORK ON ROOFS 01.12 ARE INCLUDED AS AN ALTERNATE.
SEE 1/R-7
SEE 4/R-7
U N
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
ELEVATIONS
C-1
C-1
EAST ELEVATION
SCALE: 3
32 " = 1'-0"
KEY PLAN
C-1
EAST ELEVATION
SCALE: 3
32 " = 1'-0"
C-1
NORTH EAST INNER ELEVATION
SCALE: 3
32 " = 1'-0"
C-1
C-1
C-1
NOTE:
1. PRESSURE WASH ALL CONCRETE AND EIFS WALLS AS INDICATED.
1.1. THE CONTRACTOR SHALL UTILIZE A SUB-CONTRACTOR THAT HAS FIVE YEARS OR MORE
EXPERIENCE PRESSURE WASHING FACILITIES.
1.2. THE PRESSURE SHALL BE 1,500 PSI AT THE TIP OF THE PRESSURE WASHER.
1.3. THE FLOW AMOUNT SHALL BE A MINIMUM OF 4 GPM.
1.4. THE CHEMICAL TO BE USED AS PART OF THE PRESSURE WASHING SHALL BE
ENVIRONMENTALLY FRIENDLY FOR EXAMPLE. SIMPLY GREEN OXYSOLVE HOUSE AND SIDING
1.5. CLEAN THE EXTERIOR OF ANY WINDOWS THAT MAY HAVE OVER SPRAY. ALL EIFS IS TO BE
PRESSURE WASHED AND COATED.
2. CUT / GRIND CRACKED EIFS AREA AND APPLY NEW SCRATCH COAT / FINISH COAT.
3. CUT EIFS 12 INCHES UP OR TO THE CLOSEST CONTROL JOINT, NOT EXCEEDING 2 FEET IN AREAS
WHERE FLASHING HEIGHT CANNOT BE ACHIEVED AND OTHER AREAS INDICATED IN DETAIL
DRAWINGS.
4. CONTRACTOR TO VERIFY EXTENT OF WORK TO BE DONE ON EIFS AND RE-APPLY COLORS TO
MATCH EXISTING. (VERIFY W/ OWNER) .
5. APPLY SEALER OVER IDENTIFIED SPLIT FACE BLOCK AFTER PRESSURE WASHING.
6. CONTRACTOR TO EMPLOY A LICENSED AND BONDED MECHANICAL/REFRIGERATION/ELECTRICAL
CONTRACTOR TO CUT LOOSE AND RECONNECT REFRIGERANT LINES, ELECTRICAL LINES, AND GAS
LINES, AS REQUIRED.
7. ALL ELECTRICAL CONDUIT TO BE SUPPORTED BY CONDUIT BASE STRUT. CONDUIT BASE DESIGNED
TO SUPPORT CONDUIT (GANGED) CABLE TRAYS OR OTHER MECHANICAL PIPING. EVEN LOAD
REQUIRED, MAXIMUM LOAD IS 172 LBS. (MAX LOAD BASED ON 3.0 PSI TO THE ROOF DECK).
RECOMMENDED SPACING IS NOT TO EXCEED 10' CENTERS. MAKE CERTAIN EACH SUPPORT IS
PROPERLY ELEVATED TO EVENLY DISTRIBUTE WEIGHT AT ALL SUPPORT LOCATIONS. SEE DETAILS
1/R-5 AND 2/R-5.
8. RE-COVER SLEEPERS AS SHOWN IN DETAIL 4/R-3.
9. ADJUST THROUGH WALL SCUPPER AND OVERFLOW POSITIONS TO MATCH NEW ROOF ELEVATION
AND RETAIN ORIGINAL SIZES.
10.CLEAN GUTTERS AND DOWNSPOUTS ON METAL ROOFS. REPAIR THE DAMAGED GUTTERS AND
DOWNSPOUTS AS NEEDED.
11.SPLASH PANS MUST BE ADDED TO OPEN ENDED DOWNSPOUTS.
12.ON METAL ROOFS, REMOVE AND REPLACE EXISTING FASTENERS WITH NEW NO. 14
SELF-DRILLING FASTENERS WITH SEALING NEOPRENE WASHERS. FASTENER LENGTH SHALL BE AS
REQUIRED TO FULLY PENETRATE THE METAL SUBSTRATE, BUT SHALL NOT BE LESS THAN 1 INCH.
NEW FASTENERS SHALL BE ONE SIZE LARGER THAN THE EXISTING FASTENERS. (THE ALTERNATE)
13. REPLACE BACKER RODS AND RECAULK ALL AREAS AROUND LOUVERS.
14. REPAINT ALL ROOF LADDERS AND REPLACE ANY MISSING FASTENERS.
14.1. WIRE BRUSH EXISTING LADDER FRAME TO REMOVE ANY LOOSE PAINT AND RUST. AREAS
WITH EXTENSIVE CORROSION AND/ OR STEEL SECTION LOSS SHALL BE REPORTED TO THE
ENGINEER.
14.2. THE STEEL SHALL BE COATED WITH 2 in 1 WATER-BASED RUST CONVERTER.
14.3. PAINT THE STRUCTURAL STEEL WITH SEMI-GLOSS WATER-BASED INTERIOR/EXTERIOR, 100%
ACRYLIC, SEMI GLOSS, MOLD- AND MILDEW-RESISTANT FINISH (BASES OF DESIGN) - 2 COATS
WITH PRIMER, 375 SQ. FT. PER GALLON. THE OWNER SHALL PICK THE COLOR.
15.FOR TRANSLUCENT WINDOW, FLASHING HEIGHT SHALL BE MINIMUM OF 8 INCHES, AND
CONSTRUCTED ACCORDING TO DETAIL 2/R-3. DO NOT USE IMPACT ON THE WINDOW WHEN
PLACING FASTENERS.
16.A 2-1/2 INCHES DEEP REGLET SHALL BE USED FOR FLASHING BRICKS AND BLOCKS MARKED
BRICKWALL.
17.THE METAL ROOF WORK FOR THIS PROJECT IS INCLUDED AS AN ALTERNATE.
SEE NOTES #1 TO #4 / C-1 EIFS BRICKWALL
STANDING SEAM
METAL ROOF
ALUMINUM AROUND
COLUMN AND BEAM
SPLIT FACE BLOCK
SEE NOTES #1 TO #4 / C-1 EIFS BRICKWALL
SEE NOTES #1 TO #4 / C-1 EIFS BRICKWALL
REMOVE ONE HANGING BRICK
AND MORTAR BELOW IT SEE 3/C-5
FOR CONSTRUCTION
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
ELEVATIONS
C-2
KEY PLAN
C-2
NORTH ELEVATION
SCALE:
32 " = 1'-0"
C-2
NORTH ELEVATION
SCALE:
32 " = 1'-0"
C-2
NORTH ELEVATION
SCALE:
32 " = 1'-0"
C-2
C-2
C-2
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
STANDING SEAM METAL ROOF
SEE NOTES #1 TO #4 / C-1
SEE NOTES #1 TO #4 / C-1
EIFS
SPLIT FACE BLOCK
SPLIT FACE BLOCK
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
SPLIT FACE BLOCK
STANDING SEAM
METAL ROOF
ALUMINUM AROUND
COLUMN AND BEAM
DOWNSPOUT
NEW PLATFORM POSITION
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND LOUVRES
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
ELEVATIONS
C-3
KEY PLAN
C-3
SOUTH ELEVATION
SCALE:
32 " = 1'-0"
C-3
SOUTH ELEVATION
SCALE:
32 " = 1'-0"
C-3
SOUTH ELEVATION
SCALE:
32 " = 1'-0"
C-3
C-3
C-3
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
STANDING SEAM
METAL ROOF
ALUMINUM AROUND
COLUMN AND BEAM
SPLIT FACE BLOCK
SPLIT FACE BLOCK
DOWNSPOUT
SEE NOTES #1 TO #4 / C-1
EIFS BRICKWALL
SPLIT FACE BLOCK
SEE NOTES #1 TO #4 / C-1 EIFS
BRICKWALL
STANDING SEAM
METAL ROOF
SPLIT FACE BLOCK
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND LOUVRES
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
ELEVATIONS
C-4
KEY PLAN
C-4
WEST INNER ELEVATION
SCALE:
32 " = 1'-0"
C-4
SOUTH EAST ELEVATION
SCALE:
32 " = 1'-0" 2
C-4
NORTH WEST INNER ELEVATION
SCALE:
32 " = 1'-0"
C-4
WEST ELEVATION
SCALE:
32 " = 1'-0"
C-4
WEST ELEVATION
SCALE:
32 " = 1'-0"
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
STANDING SEAM
METAL ROOF
ALUMINUM AROUND
COLUMN AND BEAM
SPLIT FACE BLOCK
SPLIT FACE BLOCK
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
SPLIT FACE BLOCK
SEE NOTE #1 / C-1
BRICKWALL
SEE NOTES #1 TO #4 / C-1
BRICKWALL
SPLIT FACE BLOCK
EIFS
SEE NOTES #1 TO #4 / C-1
EIFSNEW ACCESS
PLATFORM
SEE R-6
C-4
EAST INNER ELEVATION
SCALE:
32 " = 1'-0"
C-4
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND LOUVRES
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RE-CAULK ALL AREAS
AROUND DOOR TPICAL
IO
N
C O
U N
T Y
P U
B L
IC
S
C H
O O
L S
N
C
H U
R C
H S
T
M O
N R
O E
N
C
M A
R V
IN
R
ID
G
E H
IG
H
S C
H O
O L
R O
O F
R E
N O
V A
T
IO
N P
R O
J E
C T
C
R A
N E
R O
A D
W A
X H
A W
N
C
ELEVATIONS
C-5
KEY PLAN
C-5
EAST ELEVATION
SCALE:
16" = 1'-0"
C-5
EAST ELEVATION
SCALE:
32 " = 1'-0"
C-5
C-5
C-4
C-4
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
SPLIT FACE BLOCK
SEE NOTES #1 TO #4 / C-1EIFS
STANDING SEAM
METAL ROOF
SPLIT FACE BLOCK
SEE DETAIL 2/R-3
C-5
EAST ELEVATION
SCALE:
32 " = 1'-0"
SEE NOTES #1 TO #4 / C-1
EIFS
BRICKWALL
REPAIR BRICK SEE 1/R-7
C-5
BRICK REPAIR
SCALE: NTS
REMOVE HANGING MORTAR PER DETAIL 4/R-7
REPAIR HANGING BRICK SEE
4/C-5
C-5
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND WINDOWS
REPLACE BACKER RODS
AND RECAULK ALL AREAS
AROUND LOUVRES
FOR CONSTRUCTION
SPLIT FACE BLOCK
SEE NOTE #5 / C-1
| Addendum 1 revised.pdf |
| Addendum 1 Revised sheet |
| 07 19 16 Block Sealant |
| Drawings Binder Marvin Ridge Addendum #1 |
File details come from the government source that posted it. Updated .