Report_GEO_AC-829579_HWY-22.pdf

PDF 2 MB Posted

Attached to
Landslide Repairs to Roadways in Añasco, Puerto Rico
Solicitation number
693C73-23-B-000009
Issued by

About this file

This solicitation is seeking sealed bids from certified Small Business Concerns for Project PR ER DOT PRMNT RPR(20), Landslide Repairs in Anasco, Puerto Rico. The project scope includes embankment stabilization and reconstruction, gabion and gravity retaining walls, drainage systems installation, milling and overlay, pavement reconstruction, pavement markings, removal and replacement of guardrails, signage, temporary traffic control, and other miscellaneous work at multiple locations damaged by hurricanes. The estimated price range for the project is $2,000,000 to $5,000,000. Bid documents are expected to be issued on or around April 10, 2023, with bid due date and location specified in the solicitation. Interested vendors must register at www.sam.gov to receive email notifications and have access to download solicitation documents. Annual Representations and Certifications must be completed at www.sam.gov and Form VETS-4212 at http://www.dol.gov/vets/vets4212.htm. The soliciting agency is the Department of Transportation Federal Highway Administration.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GEOTECHNICAL REPORT

LANDSLIDE AND ROAD DAMAGE EVALUATION

AND REPAIR RECOMMENDATIONS

PR-108 KM 20.25-20.55, AÑASCO, PR

ER-HWY-22

AC-809544

Submitted to:

José A. Batlle Montalvo, PE

José A. Batlle y Asociados, CSP

Prepared by:

Carlos R. Sierra Del Llano, MSCE, PE

Rommel Cintrón Aponte, MSCE, PE

Date:

February 7, 2019

Revision:

August 14, 2020

Job no. 7932

P

O

B o x

S a n

J u a n

P

R

Geotechnical Report: Site ER HWY 22

Road Damage Evaluation and Repair Recommendations PR 108 KM 20.25-20.55 Añasco, PR

J a c a & S i e r r a E n g i n e e r i n g , P S C

P O B o x 3 6 3 1 1 6 , S a n J u a n , P R 0 0 9 3 6 - 3 1 1 6

R o a d 8 5 0 K m 0 . 2 L a s C u e v a s W a r d , T r u j i l l o A l t o , P R 0 0 9 7 6

T . 7 8 7 - 7 6 1 - 2 5 7 0 w w w . j a c a s i e r r a . c o m

1. Introduction

The present geotechnical report addresses the geotechnical conditions and recommendations for the road damages at the reference site location. This investigation is prepared based on approved scope of work and economical proposal by Jose A. Batlle y Asociados, CSP. This report is part of a multiple site assessment project for similar landslide rehabilitation cases related to damages by Hurricane

Maria on September 20, 2017. This report is prepared exclusively for design purposes.

2. Scope of Work

The scope of work consisted of two (2) test borings to 20 to 30 ft (6.1 to 9.1 mts) depth.

Borings were completed with a trailer-mounted CME-45 drill rig at accessible locations along the side of the road. Test borings and soil sampling were performed by auger drilling in accordance to ASTM D1452 and soil sampling per Standard

Penetration Test (SPT) method per ASTM D1586. Refer to enclosed boring location plan for reference on boring location (Appendix A Figure A2).

3. Site Geology

Based on the USGS Geology Map (refer to Appendix A Figure A1), the site falls within

Kb – Rio Blanco Formation. The rock formation consists of a massive well indurated tuff breccia with blocks of basalt and andesite. This formation was encountered to be weathered into a clayey silt saprolite soil, as described below.

Site ER HWY 22

PR 108 KM 20.25-20.55 Añasco, PR

P A G E | 2

0 8 / 1 4 / 2 0 Jaca & Sierra Engineering, PSC

t. 787-761-2570 e. contact@jacasierra.com www.jacasierra.com

4. Site Stratigraphy

Stratum no. 1: Fill: A fill deposit was encountered at both locations having depths of

19 to 29 ft beneath existing ground surface. The fill consisted mostly of sandy clay having similar characteristics of natural soils, but with evident physical remolding effect and occurring organic matter. SPT-N values ranged from 8 to 16 blows/ft and moisture contents from 20 to 42 %. Per soil classification tests, this fill material has classification of AASHTO A-6 and A-7-6. The upper 2 feet of fill consists of sandy gravel.

Stratum no. 2: Saprolite: A saprolite soil was encountered at both locations extending to the end of test borings at 20 and 30 ft beneath existing ground surface. The saprolite soils consisted of clayey silt with traces of sand and relic joints. SPT-N values ranged from 9 to 12 blows/ft and moisture contents from 40 to 54 %.

5. Geotechnical Recommendations

5.1. Opinion on Probable Causes for Road Damage

It is our opinion that the apparent cause of failure is related to a shallow landslide and clayey soil slope displacement occurring by over-steepening of the slope due to erosion. Slope deformation led to breakage of an existing water pipe that caused localized erosion gully on the slope (Figures B1 and B3). The approximate slide dimensions are 8.5 mts long by 3.5 mts wide by 5 mts deep (elevations from 150 to 145 mts). The depth of the slide scarp at the edge of the road is about 1 to 1.5 mts.

5.2. Slope Rehabilitation Alternatives

5.2.1. Concrete Cantilever Retaining Wall: This option has the advantage that it can be built right on the edge of the road as a jersey barrier extension (typical PRHTA section). The closer the retaining wall is to the roadway edge, the less the retaining mailto:contact@jacasierra.com

P A G E | 3

0 8 / 1 4 / 2 0 wall height required. It being the option that can be built as close as possible to edge of road, it is the alternative having the lowest required height. The wall foundation depth shall be at minimum 1.2 mts (4 ft) beneath slope face as measured from the lower side. The slope along the gully can be restored with engineered fill at 2:1 (H:V).

5.2.2. Gabion Wall: This option will need a retaining wall to be offset from the edge of the road to allow placement of a guard rail or a jersey barrier. Based on profiles provided to us, the wall height will be in the order of 5.5 mts (18 ft).

5.2.3. Reinforced Soil Slope (RSS): This option will entail excavation of the existing slope, which will be to an extent requiring closing the road and then placement of reinforced engineered fill in layers up to final grades. RSS can have a slope inclination of 1:1 to 1:1.5 (H:V).

5.2.4. Concrete Gravity Wall: This option has the advantage of minimizing excavation width at the edge of the road. The gravity wall can be designed per

PRHTA’s standard design section to be verified and adjusted by designer based on the herein provided bearing capacity and earth pressure parameters. Similar to the cantilever wall, it shall be embedded at least 1.2 mts (4 ft) below slope surface as measured from the lower side.

P A G E | 4

0 8 / 1 4 / 2 0

5.3. Earth Pressure Parameters for Retaining Wall Design

Strength or Earth Pressure Parameters

Engineered Fill /

Retaining Wall

Backfill

In-Situ Soils

Drained cohesion, c, kPa (psf) 0 (0) 9.6 (200)

Drained angle of internal friction, φ, ˚ 32 24

Undrained cohesion, c, kPa (psf) - 47.9 (1,000)

Undrained angle of internal friction, φ, ˚ - 0

Moist unit weight, γ, kN/cu.mt. (pcf) 20.4 (130) 18.1 (115)

Seismic horizontal coefficient, kh - 0.2

Base shear coefficient, * - 0.3

Net allowable bearing capacity for retaining wall over native soil, qa, kPa (psf)

- 95.8 (2,000)

Table 1: Earth pressure parameters for retained soils

*For passive resistance neglect upper 4 ft, for passive side unit weight of backfill assume 15.7 kN/cu.mt. (100 pcf).

Calculations of allowable bearing capacity, base shear coefficient and seismic horizontal coefficient are presented in Appendix D. Settlements are considered below

1 inch due to the presence of underlying stiff sandy clay. A conservative rough estimate of consolidation settlement is also shown in Appendix D to support the assumption of expected settlement within a tolerable limit.

5.4. Global Stability Analysis Results

Soil

Condition Seismic Coefficient

Minimum Factor of Minimum Factor of

Safety Obtained Safety Required

Drained None (Static) 1.750 1.500

Drained Horizontal (Pseudostatic) 1.195 1.125

Undrained None (Static) 2.684 1.500

Undrained Horizontal (Pseudostatic) 1.968 1.125

Table 2: Summary of global stability analysis results

GEO-SLOPE SLOPE/W Version 5.2 software was used for global stability analysis of the preferred gravity wall alternative. Results and relevant information are presented in Appendix E.

P A G E | 5

0 8 / 1 4 / 2 0

6. Generalized Recommendations

6.1. Recommended Backfill Material: All engineered fill shall consist of A-2-4 or

A-1 AASHTO Classification fill placed and compacted to 95 % of the modified Proctor density. Engineered fill shall be handled and placed per latest applicable PR Highway

Authority Specifications. Engineered fill shall be monitored by soil technician with guidance from a geotechnical engineer.

6.2. Fill Recommendations: Any fill shall be constructed upslope in horizontal layers and benched terraces shall be cut at the interface of fill and natural soils. The benches shall have a minimum width of 0.9 mts and shall be made at a maximum vertical distance of 0.9 mts as fill progresses upward. Unreinforced engineered fill slopes shall not exceed 2:1 (H:V) inclination.

6.3. Drainage: Road drainage shall be controlled by jersey barriers, curbs and gutters or storm runoff management devices designed in such way that it prevents any overland water discharge over the project areas.

6.4. Slope Erosion Control: Protect all slopes disturbed by excavation process with sodding or turf reinforcement. Deep rooted vegetation, such as vetiver and ferns

(“helechos”) is recommended within any area impacted by the project. For this particular case, we recommend avoiding disturbance of existing vegetated slopes downslope of the retaining wall, thus limiting the above erosion control measures to areas impacted by excavations and retaining wall construction.

6.5. Differing Site Conditions: These recommendations are based on test borings performed on locations, which are considered as representative of the subsoil conditions within the site, but not all areas of the site could be explored due to limitations of access. Therefore, differing site conditions could occur. In such instances, we shall be notified to proceed with a field visual inspection directed to formulate the corresponding solution.

P A G E | 6

0 8 / 1 4 / 2 0

6.6. Excavation Safety: Contractor is responsible to adjust excavation inclination and provide shoring, where necessary, to ensure safety of working personnel per latest applicable OSHA excavation safety standards. The contractor shall consult with geotechnical engineer or geologist on excavation inclination and shoring requirements.

6.7. Geotechnical Engineer Confirmation: The excavations shall be coordinated with the undersigned to conduct a site visit by a representative from Jaca & Sierra

Engineering, PSC to verify conditions and confirm foundation depth among other geotechnical considerations.

Thanks for the opportunity of providing our field investigation, testing and engineering consulting services. Feel free to contact us for any questions on our report.

Respectfully submitted, JACA & SIERRA ENGINEERING, PSC

Carlos R. Sierra Del Llano, MSCE, PE

Rommel Cintron Aponte, MSCE, PR

P A G E | 7

0 8 / 1 4 / 2 0

Appendix A: Geology Map and Boring Location Plan

Figure A1: Site Geology Map (McIntyre, D.H., 1971, Geologic map of the Central La Plata quadrangle, Puerto

Rico: U.S. Geological Survey, Miscellaneous Geologic Investigations Map I-660)

SITE

P A G E | 8

0 8 / 1 4 / 2 0

Figure A2: Boring Location Map (Topography Drawing by Javier E. Bidot & Associates, PSC)

P A G E | 9

0 8 / 1 4 / 2 0

Appendix B: Site Conditions Photographic Images

Figure B1: Landslide Area, Erosion Gully Location

Figure B2: Temporary Water Pipe Replacement Excavation

P A G E | 1 0

0 8 / 1 4 / 2 0

Figure B3: Erosion Gully Area

Figure B4: Landslide Area

Appendix C:

Boring Logs and Laboratory Tests

150.30

149.69

144.51

FILL: sandy gravel, brown

FILL: sandy clay, yellowish brown, reddish brown

SAPROLITE: clayey silt trace sand, stiff, brownish red, yellowish brown, black mottled End of Boring

S-1

S-2

S-3

S-4

S-5

S-6

S-7

40 2.0

SUBSURFACE EXPLORATION LOG

BORING N0.: 22-A

PROJECT

Site ER-HWY-22

JOB

OF

SHEET 1

LOCATION Añasco, PR DRILLER/DRILL RIG: Carlos I. Diaz / CME-45 COORDINATES 248877.762 N 134782.004 E DATE HOLE STARTED 12-18-18 COMPLETED 12-18-18

DESCRIPTION BY Carlos R. Sierra Del Llano ELEVATION TOP OF HOLE (mts): 150.3 GROUNDWATER (FT) Initial: Not Found Final: ENGINEER Carlos R. Sierra Del Llano DRILLING METHOD: Hollow-Stem Auger 2.25" ID TOTAL DEPTH OF HOLE (ft): 20.5

N W Qu PL+LL

"N" - Number of blows required to drive the sampling spoon a distance of 12 in. with a 140 lbs hammer falling 30 in.

"W" - Natural Moisture Content in percentage of dry weight. Initial G.W. Depth "Qu" - Unconfined Compressive Strength in tons per square foot. Final G.W. Depth "Rc" - Core recovery in percent for each successive run. "Rqd" - Rock quality designation.

"WH" - Sample was recovered by advancing the sampler with the weight of the hammer.

"P" - A "P" in the Unconfined Compressive Strength test indicates the use of the pocket Penetrometer.

Elev.

(mts)

0.00

DEPTH

(feet) DESCRIPTION

LE

G

E N

D

S am pl e

N o.

TY

P

E

B

LO

W S

SPT

N W Qu RC RQD%

20 40 60 80

1 2 3 4

Qu

N-W

151.20

150.59

142.36

FILL: sandy gravel some silt, grayish brown

FILL: sandy clay, yellowish brown, reddish brown

Do... dusky red

Do... with organic matter, dark brown

SAPROLITE: clayey silt trace sand, stiff, brownish red, yellowish brown, black mottled End of Boring

S-1

S-2

S-3

S-4

S-5

S-6

S-7

S-8

S-9

1.4

1.5

SUBSURFACE EXPLORATION LOG

BORING N0.: 22-B

PROJECT

Site ER-HWY-22

JOB

OF

SHEET 1

LOCATION Añasco, PR DRILLER/DRILL RIG: Carlos I. Diaz / CME-45 COORDINATES 248868.725 N 134767.947 E DATE HOLE STARTED 12-18-18 COMPLETED 12-18-18

DESCRIPTION BY Carlos R. Sierra Del Llano ELEVATION TOP OF HOLE (mts): 151.2 GROUNDWATER (FT) Initial: Not Found Final: ENGINEER Carlos R. Sierra Del Llano DRILLING METHOD: Hollow-Stem Auger 2.25" ID TOTAL DEPTH OF HOLE (ft): 30.5

N W Qu PL+LL

"N" - Number of blows required to drive the sampling spoon a distance of 12 in. with a 140 lbs hammer falling 30 in.

"W" - Natural Moisture Content in percentage of dry weight. Initial G.W. Depth "Qu" - Unconfined Compressive Strength in tons per square foot. Final G.W. Depth "Rc" - Core recovery in percent for each successive run. "Rqd" - Rock quality designation.

"WH" - Sample was recovered by advancing the sampler with the weight of the hammer.

"P" - A "P" in the Unconfined Compressive Strength test indicates the use of the pocket Penetrometer.

Elev.

(mts)

0.00

DEPTH

(feet) DESCRIPTION

LE

G

E N

D

S am pl e

N o.

TY

P

E

B

LO

W S

SPT

N W Qu RC RQD%

20 40 60 80

1 2 3 4

Qu

N-W

(X=NO)PERCENTFINERSIZE

PASS?SPEC.*PERCENTSIEVE

Project No:

Project:

Client:

Elev./Depth:Location:

Date:Source of Sample:Sample No.:

Remarks

Classification

Coefficients

Atterberg Limits

Material Description

AASHTO=USCS=

Cc=Cu=

D10=D15=D30=

D50=D60=D85=

PI=LL=PL=

Particle Size Distribution Report

P E R C E N T F

IN

E R

100 10 1 0.1 0.01 0.001500

GRAIN SIZE - mm

% +75 MM % GRAVEL % SAND % SILT % CLAY

i n i n i n

-1 /2 i n i n

/4 i n

/2 i n

/8 i n

0.0 5.0 36.9 58.1

Figure7932

Site ER-HWY-22, Anasco, PR

Jose A. Batlle & Associates

4-7.5'Anasco, PR

1/2/19Project Site22-A (S-3, S-4)

Tested by: N. Rodriguez

Checked by: Carlos Sierra Del Llano, MSCE, PE

A-7-6(8)CL

0.08540.390

174124

Sandy lean clay

(no specification provided)

JACA & SIERRA

TESTING LABORATORIES

San Juan, Puerto Rico

100.0 96.4 96.4 96.0 95.0 92.8 86.1 68.8 58.1

1 in.

.75 in.

.5 in.

.375 in.

#4

#10 #40

#100 #200

(X=NO)PERCENTFINERSIZE

PASS?SPEC.*PERCENTSIEVE

Project No:

Project:

Client:

Elev./Depth:Location:

Date:Source of Sample:Sample No.:

Remarks

Classification

Coefficients

Atterberg Limits

Material Description

AASHTO=USCS=

Cc=Cu=

D10=D15=D30=

D50=D60=D85=

PI=LL=PL=

Particle Size Distribution Report

P E R C E N T F

IN

E R

100 10 1 0.1 0.01 0.001500

GRAIN SIZE - mm

% +75 MM % GRAVEL % SAND % SILT % CLAY

i n i n i n

-1 /2 i n i n

/4 i n

/2 i n

/8 i n

0.0 1.6 34.5 63.9

Figure7932

Site ER-HWY-22, Anasco, PR

Jose A. Batlle & Associates

4-7.5'Anasco, PR

1/2/19Project Site22-B (S-3, S-4)

Tested by: N. Rodriguez

Checked by: Carlos Sierra Del Llano, MSCE, PE

A-6(8)CL

0.288

143925

Sandy lean clay

(no specification provided)

JACA & SIERRA

TESTING LABORATORIES

San Juan, Puerto Rico

100.0 98.9 98.6 98.4 97.4 90.4 74.2 63.9

.75 in.

.5 in.

.375 in.

#4

#10 #40

#100 #200

Appendix D:

Geotechnical Calculations

Allowable Bearing Capacity ϕ = angle of internal friction for soil beneath foundation, c = cohesion for soil beneath foundation, su = undrained shear strength for soil beneath foundation, D = depth of foundation below ground surface, Bc = width of continuous foundation, σzD = vertical stress at depth D below ground surface, γ = soil unit weight around foundation, Nc, Nq, Nγ = Terzaghi’s bearing capacity factors in function of ϕ, qult = ultimate bearing capacity, FS = Factor of Safety, qa = allowable bearing capacity, gc, gq, gγ = Vesic’s ground inclination factors, β = ground inclination

(downslope)

Underlying Soil: Stiff sandy clay

Method: Terzaghi

Data from cross section Sta. 203+96.01: D = 3 ft, Bc = 9 ft, Gravity wall, β = 26.5˚

Data from Table 1: γ = 115 pcf

FS > 2 => FS = 2.35 considered σzD = γD σzD = 345 psf 𝑔𝑐 = 1 − 𝛽

147° gc = 0.82 𝑔𝑞 = 𝑔𝛾 = (1 − tan𝛽)2 gq = gγ = 0.25

Drained

Data from Table 1: ϕ = 24˚, c = 200 psf

Bearing capacity factors for ϕ = 24˚: Nc = 23.36, Nq = 11.40, Nγ = 7.08

Continuous Foundations qult = cNc𝑔𝑐 + σzDNq𝑔𝑞 + 0.5γBNγ𝑔𝛾 qult = 5,730 psf qa = qult

FS

qa = 2,438 psf

Undrained

Data from Table 1: ϕ = 0˚, su = 1,000 psf

Bearing capacity factors for ϕ = 0˚: Nc = 5.70, Nq = 1.00, Nγ = 0.00

Continuous Foundations qult = suNc𝑔𝑐 + σzDNq𝑔𝑞 qult = 4,760 psf qa = qult

FS

qa = 2,026 psf => qa = 2,000 psf considered

Base Shear Coefficient ϕ = angle of internal friction for soil beneath foundation, μ = base shear coefficient of friction

Underlying Soil: Stiff sandy clay

Data from Table 1: ϕ = 24˚ μ = tan(0.7φ) μ = 0.30

Seismic Horizontal Coefficient

PGA = peak ground acceleration, kh = quotient of horizontal component of earthquake acceleration and gravity acceleration, kv = quotient of vertical component of earthquake acceleration and gravity acceleration

From ASCE 7-16: PGA = 0.45 g kh =

PGA

kh = 0.23

Consolidation Settlement

This is a rough estimate to support the assumption of consolidation settlement lower than 1 inch.

H = soil layer thickness, z = depth at midpoint of soil layer, σz0 = initial vertical stress at midpoint of soil layer, d = depth of foundation below ground surface, zf = depth below bottom of foundation, bc = width of continuous foundation, Iσc = stress influence factor for continuous foundation, q = bearing pressure along bottom of foundation, γ = soil unit weight around foundation, σzd = vertical stress at depth d below ground surface, Δσz = induced vertical stress due to load from foundation, σzf = final vertical stress at midpoint of soil layer, Cr = recompression index, e0 = initial void ratio, CR = Cr/(1+e0), δc = consolidation settlement

Data from Borings no. 22-A & 22-B, 10-15 ft depth (5 ft zone below bottom of foundation), Stiff sandy clay, N = 8-11 bpf

Data from cross section Sta. 203+96.01: d = 3 ft, bc = 9 ft, Gravity wall

Data from Table 1: γ = 115 pcf, q = 2,000 psf

Assumptions: H = 5 ft, z = 5.5 ft, Overconsolidated soils σz0i = γ1H1 + γ2H2 +⋯+ γnHn σz0 = 115(2.5) = 288 psf zfi = z − d zf = 2.5 ft

Continuous Foundation

Iσci = 1 − (

1 + ( bc 2zf

)1.38 )2.6

Iσc = 0.95 σzd = γd σzd = 345 psf

∆σzi = Iσ(q − σzd) Δσz = 1,578 psf σzfi = σz0 + ∆σz σzf = 1,865 psf

CRi = Cr

1 + e0

CR = 0.01 => Assumed conservative value δci = CRHlog( σzf σz0 δc = 0.49 in δc = δc1 + δc2 +⋯+ δcn δc = 0.49 in < 1 in

Appendix E:

SLOPE/W Software Results

Figure E1

Figure E2

Figure E3

Figure E4

Front Page 22.pdf
Geotechnical Report Site 22
Apendice C
Boring Logs 7932 22
Soil Classifications 7932 22
Apendice D
Geotechnical Calculations 22
Apendice E
SlopeW 22

File details come from the government source that posted it. Updated .