About this file

This is a glass specifications document for the City of St. Petersburg, Florida, related to the replacement of a shattered storefront glass panel at the St. Pete Pier's Tampa Bay Watch tenant building. The document provides detailed technical specifications for the insulating glass unit to be installed, which consists of Solarban 70 on Optiblue (Solarban z75) 6mm outer lite, a 1/2-inch air space, and a 6mm clear laminate indoor lite. The specifications include performance data based on ANSI/NFRC standards, with detailed measurements for thermal properties, solar performance, light transmittance, and other optical characteristics. The document emphasizes that the glazing must be sourced from Vitro Certified Network manufacturers and notes that the glass lites are Cradle to Cradle certified by McDonough Braungart Design Chemistry, LLC. All performance data represents center-of-glass measurements and may vary slightly due to production process variations.

The specifications document serves as a technical reference for vendors submitting quotes for the glass panel replacement project. Vitro, the glass manufacturer, assumes no responsibility for the accuracy of data from non-Vitro manufacturers and recommends that a full-size mock-up be reviewed under specific job-site conditions. The document stresses the recipient's responsibility to ensure manufacturability, evaluate design considerations including wind and snow load analysis and thermal stress analysis, and verify local building code compliance. No specific pricing terms, bid amounts, response dates, or contract award information is provided in this specifications document; it functions solely as the technical reference material for the procurement process.

View the file

Other files

File Type Posted
Glass_Panel_Replacement,_St._Pete_Pier_(Addendum_#1_Revision).pdf PDF
Glass_Panel_Replacement,_St._Pete_Pier.pdf PDF
Base_Agreement.pdf PDF
Dimensions_of_Glass_.pdf PDF
Light_Construction_Agreement.docx DOCX document
Public_Construction_Bond.docx DOCX document
Subcontractor_Summary_-_Sheltered_.xlsx XLSX spreadsheet
Subcontractor_Utilization_Plan.docx DOCX document
Performance_&_Payment_Bond_.DOCX DOCX document
Subcontractor_Summary_Spreadsheet.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solarban® 70 on Optiblue® {Solarban® z75} 6mm (2) | Air 1/2" (12.7mm) | 6mmClear_090SG_6mmClear

1 1/4 " 0 44 16 30 9 12 0.28 0.26 0.26 0.22 2.00 Med

Specifications Insulating Unit Construction Solarban® 70 on Optiblue® {Solarban® z75} 6mm (2) | Air 1/2" (12.7mm) | 6mmClear_090SG_6mmClear

Outdoor Lite: Optiblue® with a second surface Solarban® 70

Indoor Lite: Laminate-6mmClear_090SG_6mmClear

Vitro Approved Manufacturers/Where to Buy Vitro Products: Vitro Certified™ Network

Certification: Vitro lite(s) are Cradle to Cradle certified by McDonough Braungart Design Chemistry, LLC (MBDC www.mbdc.com)

Note: Be aware that lam inated glazing constructions may have increased optical distortion and/or strain iridescence from stacked multiple individual layers especially when the glass lites are heat treated. In addition transmitted and reflective color differences can occur when a low-e or reflective coating is located adjacent to the interlayer material. A coating facing an airspace in an IG unit may appear a different color than the same coating in a lam inate.

Optiblue®: Optiblue® glass is a light-bodied, neutral color tint designed to complement Solarban® glasses

Solarban® 70: Solarban® 70 glass is a high performing MSVD solar control low-e glass. Though the coating is transparent (on clear or Acuity Low-Iron glass), it can also be paired with, or applied directly on most Vitro tinted glasses in an insulating glass unit.

The results represent Center-of-Glass performance data based on ANSI/NFRC 100 and ANSI/NFRC 200 Environmental Design Conditions utilizing the LBNL Window 7.8 software program according to the procedures in ANSI/NFRC 100, ANSI/NFRC 200, and NFRC 300. Performance data is based on representative samples of factory production. Actual values may vary slightly due to variations in the production process. This data is to be used for comparison purposes and should not be considered a contract. For configurations that include diffuse components, performance results cannot be verified and should only be used as a general indication of performance. It is the recipient’s responsibility to ensure the manufacturability of the above glazing configurations as well as evaluating appropriate design considerations such as wind and snow load analysis, thermal stress analysis, and local building code compliance. Vitro makes no warranty or guarantee as to the results obtained by the user and assumes no responsibility for the accuracy of the data from non-Vitro manufacturers utilized in the above simulations. Vitro recommends that a full size mock-up be reviewed under the specific job-site conditions and retain the mock-up as a basis of acceptable product.

Vitro Architectural Glass | 400 Guys Run Road Cheswick, PA 15024 USA | ©2001-2026 Vitro Flat Glass llc. - All Rights Reserved | Legal Notices & Privacy Policy

Atlantica, Azuria, Graylite, IdeaScapes, Optiblue, Optigray, Pacifica, Solarban, the Solarban logo, Solarblue, Solarbronze, Solarcool, Solargray, Solexia, Starphire, the Starphire logo, Sungate, Vistacool, Vitro, the Vitro logo, and the Vitro Certified network logos are registered trademarks owned by Vitro. Cradle to Cradle is a trademark of MBDC.

Glass colors represented are approximate.

While Vitro has made a good faith effort to verify the reliability of this computer based tool, it may contain unknown programming errors that may result in incorrect results. The user is encouraged to use good judgment and report any questionable results to Vitro for evaluation. The applicability and subsequent results of data simulated by this tool will be compromised if the user fails to input the correct information. Vitro makes no warranty or guarantee as to the results obtained by the user of this tool and assumes no responsibility for the accuracy of the data from non-Vitro manufacturers available for simulations in this program.

Thic knes s (i nch es)

Tran sm itta nce

UV %

Tran sm itta nce

Visi ble

Tran sm itta nce

Tota l S ola r

Ext eri or

Sola r R efl ect anc e

Ext eri or

Visi ble

Refl ect anc e %

Int eri or Visi ble Refl ect anc e

U-Valu e (W int er

Nigh ttim

e) ( Btu/ hr* ft2

*°F

U-Valu e(S um mer

Dayt im e)

(Btu/ hr* ft2 *°F

Shad ing

Coef fic ien t (S

C)

Sola r H eat Gain

Coef fic ien t

(SHGC)

Ligh t T o S ola r G ain

(L

SG)

Ther mal S tre ss

Risk

(If ann eal ed gla ss)

Construct- Vitro Glass Configurator Page 1 of 1 https://construct.vitroglazings.com 09/11/2026 http://www.mbdc.com http://vitro.com/en/terms-and-conditions https://construct.vitroglazings.com

File details come from the government source that posted it. Updated .