REK-30X64 Building Structural Design Specifications
This document is a structural design drawing and technical specification sheet for a prefabricated steel building structure (REK-30X64 model) produced by PolygonCorp, a fabricator with certifications and approvals from multiple jurisdictions including Miami-Dade County, the City of Phoenix, the City of Los Angeles, the City of Riverside, the City of Houston, Clark County Nevada, the State of Utah, and AISC. The building is a 30-foot by 64-foot structure with a multi-rib metal roof system featuring a 24-gauge galvalume-coated Kynar 500 painted finish. The structure includes detailed architectural elevations showing 12 feet 7 inches reference height with 7 feet 6 inches clear interior space, a structural framing plan at 1:128 scale, and a column layout indicating 26 feet by 20 feet typical spacing across a 60-foot dimension with 65 feet 5 inches reference width. The drawing package indicates this is preliminary planning and estimating documentation only and is not approved for construction use.
The structural materials specified include tube steel (ASTM A500 Grade B), pipe (ASTM A53 Grade B and A519), light-gauge cold-formed structural steel (ASTM A1003 Grade 50), plate steel (ASTM A36), and roof panels (ASTM A653). All structural steel must be detailed, fabricated, and erected per the American Institute of Steel Construction (AISC) Specification Manual, with all welding performed by AWS-certified welders conforming to AWS D1.1 or D1.3 standards. The fabricator recommends that primary frame installers and roof installers maintain a minimum of five years documented experience with this product type. Field electrical wiring installation is recommended to occur after the building structure is erected. The manufacturer requires contact for any modifications involving attached walls, column wraps, railings, or changes to the standard 20-foot separation assumption between adjacent structures.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THROUGH THE STRUCTURAL MEMBERS BEFORE THE BUILDING IS
INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION MANUAL.
GENERAL NOTES:
UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED TO
ONLY SUPPORT WHAT IS SHOWN ON THESE DRAWINGS. THE
MANUFACTURER MUST BE CONTACTED IF ANYTHING ELSE IS TO BE
ATTACHED TO THIS STRUCTURE (WALLS, COLUMN WRAPS, RAILINGS,
ETC.) SO THE DESIGN OF THIS STRUCTURE CAN BE REVIEWED AND
POSSIBLY REVISED.
UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED
ASSUMING A 20' SEPARATION BETWEEN ANY ADJACENT STRUCTURE
WITH AN EAVE HEIGHT EQUAL TO OR GREATER THAN THE EAVE
HEIGHT OF THIS STRUCTURE. IF THAT SEPARATION DOES NOT EXIST,
THE MANUFACTURER MUST BE CONTACTED SO THE DESIGN OF THIS
STRUCTURE CAN BE REVIEWED AND POSSIBLY REVISED.
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED
IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN
ALL WELDING IS PERFORMED BY AMERICAN WELDING SOCIETY
(AWS) CERTIFIED WELDERS AND CONFORMS TO THE LATEST EDITION
OF AWS D1.1 OR D1.3 AS REQUIRED.
PARTS SHOWN MAY BE UPGRADED DUE TO STANDARDIZED
FABRICATION. REFER TO THE SHIPPING BILL OF MATERIALS FOR
POSSIBLE SUBSTITUTIONS.
FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS
RECOMMENDED THAT THE PRIMARY FRAME INSTALLER AND THE
ROOF INSTALLER HAVE A MINIMUM FIVE (5) YEARS DOCUMENTED
EXPERIENCE INSTALLING THIS TYPE OF PRODUCT.
FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS
RECOMMENDED THAT ELECTRIC WIRING, IF REQUIRED, BE RUN
ERECTED.
MATERIALS:
DESCRIPTION
TUBE STEEL
SCHEDULE PIPE
RMT PIPE
LIGHT GAGE COLD FORMED
STRUCTURAL STEEL PLATE
ROOF PANELS (STEEL)
ASTM DESIGNATION
A500 (GRADE B)
A53 (GRADE B)
A519
A1003 (GRADE 50)
A36 A653
CERTIFICATES:
MIAMI-DADE COUNTY CERTIFICATE OF COMPETENCY NO. 21-0819.13
PCI (POWDER COATING INSTITUTE) 4000 CERTIFIED
FABRICATOR APPROVALS:
CITY OF PHOENIX, AZ APPROVED FABRICATOR #C08-2010
CITY OF LOS ANGELES, CA APPROVED FABRICATOR #FB01596
CITY OF RIVERSIDE, CA APPROVED FABRICATOR #SF_000042
CITY OF HOUSTON, TX APPROVED FABRICATOR #470
CLARK COUNTY, NV APPROVED FABRICATOR #264
STATE OF UTAH APPROVED FABRICATOR 02008-14
AISC APPROVED FABRICATOR C-00018751
STOP!!
USE FOR PRELIMINARY
PLANNING AND ESTIMATING
ONLY
NOT FOR CONSTRUCTION
R
R
M A
IN
(6
-3 b y
P O
R T
E R
C O
R P
W W
W .P
O L
IG
O
N .C
O M
F
IE
L D
S U
P P
O R
T
(6
-3
SHEET
ORDER NUMBER:
C A
D M
O D
E L:
C O
V E R
S H
E E T
BUILDING NUMBER:
PROJECT:
:9
LOCATION:
DRAWING LIST:
MULTI-RIB
P R
O J E C
T L
O C
A
TI
O N
P R
O J E C
T:
D
R A
W N
B Y
A
2022A
REK 30x64
R E K
-3 x
-E
W
D R
A W
IN
G c h ri s.
lis a c J O
B N
O
S C
A
LE
P R
IN
T
D A
TE
ROOF TYPE:
/2
/2
R E V
L E V
E L:
BUILDING TYPE:
CS
QUOTE NUMBER:
SHEET NUMBER DRAWING DESCRIPTION
CS COVER SHEET
1 ARCHITECTURAL ELEVATIONS
2 STRUCTURAL FRAMING PLAN
3 COLUMN LAYOUT
SHEET NUMBER DRAWING DESCRIPTION
CS COVER SHEET
1 ARCHITECTURAL ELEVATIONS
2 STRUCTURAL FRAMING PLAN
3 COLUMN LAYOUT
STOP!!
USE FOR PRELIMINARY
PLANNING AND ESTIMATING
ONLY
NOT FOR CONSTRUCTION
R
PORTER
PATENTED OR PATENTS PENDING
(616)399-1963 by
PORTERCORP 4240 N. 136th AVE HOLLAND, MI 49424 www.poligon.com
CORPCOPYRIGHT 2016
12'-7"
REF
7'-6"
CLEAR
ARCHITECTURAL ELEVATIONS
GENERAL ROOF NOTES:
METAL ROOFING:1.
24 GAUGE•
GALVALUME COATED•
KYNAR 500 PAINTED•
TRIM COLOR MATCHES ROOF2.
SEE POLIGON.COM FOR 3.
COLOR OPTIONS
1:128
SCALE: REV LEVEL:
A
DRAWING:
SHEET
30'-0"
64'-0"
FINISH GRADE.
MOUNTING VARIES
BASED ON ENGINEERING
REQUIREMENTS.
PLANNING AND ESTIMATING
ONLY
NOT FOR CONSTRUCTION
R
PORTER
PATENTED OR PATENTS PENDING
(616)399-1963 by
PORTERCORP 4240 N. 136th AVE HOLLAND, MI 49424 www.poligon.com
CORPCOPYRIGHT 2016
STRUCTURAL FRAMING PLAN
SHEET
SCALE:
1:128 A
REV LEVEL:
FINISH GRADE.
MOUNTING VARIES
BASED ON ENGINEERING
REQUIREMENTS.
PLANNING AND ESTIMATING
ONLY
NOT FOR CONSTRUCTION
R
PORTER
PATENTED OR PATENTS PENDING
(616)399-1963 by
PORTERCORP 4240 N. 136th AVE HOLLAND, MI 49424 www.poligon.com
CORPCOPYRIGHT 2016
26'-0"
20'-0"
TYP
60'-0"
32'-10"
REF
65'-5"
REF
COLUMN LAYOUT
1:96
SCALE: REV LEVEL:
A
BASEPLATE NOTES:
POLIGON ENGINEERING WILL DETERMINE REQUIRED BASEPLATE 1.
DESIGN AFTER ENGINEERING PACKAGE IS ORDERED.
CUSTOMER MAY SUGGEST PREFERRED BASEPLATE DESIGN.2.
FRAME COLOR: SURREY BEIGE
ROOF COLOR: EVERGREEN
COLORS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. FOR OTHER
COLOR SELECTIONS, PLEASE SUBMIT AN E1 DRAWING REQUEST. REK 30x64