Range drawings.pdf
PDF 7 MB Posted
- Attached to
- Firing Range Cleaning Federal contract opportunity
- Solicitation number
- FA671225Q0001
About this file
This file contains technical drawings and specifications related to an Air Force small arms range repair project at the 911th Airlift Wing in Pittsburgh. The drawings include detailed specifications for baffle systems, anchor bolt plans, structural details, and door jamb assemblies for the firing range. The documents show multiple technical drawings with precise measurements and specifications for components like suspended baffles (48" x 96" x 3/8"), AR500 steel plates, mounting brackets, and acoustic panels.
The drawings appear to be related to the physical infrastructure and safety systems of the firing range, particularly focusing on ballistic protection components and structural supports. Key specifications include detailed measurements for baffle angles (ranging from 75.25" to 96" in length), gap protectors, and mounting hardware. The documents include both plan views and cross-sectional details showing installation requirements and assembly configurations. The drawings are primarily from Range Systems and Boardman Steel Fabricators, dated between 2014-2016, and include revision histories and weights for various components.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Range Cleaning Questions 03202025.docx | DOCX document | |
| Sign in sheet Site Visit.pdf | ||
| Pictures Range.docx | DOCX document | |
| Firing Range Cleaning PWS March 2025 .docx | DOCX document | |
| Wage Determination 2015-4235 rev 29 Dec 23 2024.pdf | ||
| Quote Template.xlsx | XLSX spreadsheet | |
| FY 24 AMMO ALLOCATION.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
43"
Other
22"
29"
36"
49"
Top
33"
24"
41"
#4
#6
#3
Size
#5
Bar
56"
37"
28"
Top
47"
37"
Other
25"
19"
31"
43"
Top
29"
22"
36"
34"
23"
17"
28"
Class B Tension Lap Splice
Other f'c = 3000 psi f'c = 4000 psi f'c = 5000 psi
33"
Other
17"
22"
28"
37"
Top
25"
19"
31"
#4
#6
#3
Size
#5
Bar
43"
29"
22"
Top
36"
29"
Other
19"
15"
24"
34"
Top
23"
17"
28"
26"
17"
13"
22"
Class A Development Length, ld
Other f'c = 3000 psi f'c = 4000 psi f'c = 5000 psi
DESIGN LOADS
Floor live load (unless otherwise noted)
Slab on ground ----------------------------------------------------------------------- 100 psf
Roof live load
Roof live load --------------------------------------------------------------------------- 20 psf
Roof snow load
Ground snow load (ASCE 7, Figure 7-1) -------------------------------------- Pg = 25 psf
Flat-roof snow load (ASCE 7, 7.3) ----------------------------------------------- Pf = 20 psf
Snow exposure factor (ASCE 7, Table 7-2) ----------------------------------- Ce = 0.9
Snow importance factor (ASCE 7, Table 7-4) --------------------------------- Is = 1.0
Thermal factor (ASCE 7, Table 7-3) --------------------------------------------- Ct = 1.2
Wind design data
Basic wind speed (3-second gust) (ASCE 7, Figure 6-1) ------------------ V = 90 mph
Wind importance factor (ASCE 7, Table 6-1) --------------------------------- Iw = 1.0
Occupancy category ( ASCE 7, Table 1-1 ) ------------------------------------- II
Wind exposure category ( ASCE 7, Section 6.5.6 ) --------------------------- C
Internal pressure coefficient (ASCE 7, Fig. 6-5) Encl. ----------------------- GCpi = ±0.18
Components and cladding
Effective Wind Area ---------------------------------------------------------- 10 ft² (1)
Zone 1 (Roof Interior) ------------------------------------------------------- +10.0, -17.7 psf
Zone 2 (Roof Edge) --------------------------------------------------------- +10.0, -29.5 ps f
Zone 3 (Roof Corner) ------------------------------------------------------- +10.0, -44.5 psf
Zone 4 (Wall Interior) ------------------------------------------------------- +17.7, -19.1 psf
Zone 5 (Wall Corner) ------------------------------------------------------- +17.7, -23.6 ps f
(+) Indicates pressure acting toward the surface
(-) Indicates pressure acting away from the surface
Edge and corner zones are defined as areas within 6'-0" of edge or corners
Uplift on canopies and overhangs ------------------------------------------------ 25.4 psf
(1) Components and cladding engineer may calculate wind loads based on actual effective wind area per ASCE 7
Earthquake design data
Seismic importance factor (ASCE 7, Table 11.5-1) -------------------------- Ie = 1.0
Occupancy category ( ASCE 7, Table 1-1) ------------------------------------- II
Mapped spectral response accelerations
Short period ------------------------------------------------------------------- Ss = 0.124 g
1-second period -------------------------------------------------------------- S1 = 0.049 g
Site class (assumed) ---------------------------------------------------------------- D
Spectral response coefficients
Short period ------------------------------------------------------------------- Sds = 0.132 g
1-second period -------------------------------------------------------------- Sd1 = 0.078 g
Seismic design category ------------------------------------------------------------ B
Basic seismic-force-resisting system (ASCE 7, Table 12.2-1)
A. Bearing wall systems
1. Ordinary Reinforced Concrete Shear Walls
Design base shear (ASCE 7, 12.8.1) -------------------------------------------- V = 6.2 Kips
Seismic response coefficient (ASCE 7, 12.8.1.1) ----------------------------- Cs = .03
Response modification factor (ASCE 7, Table 12.2-1) ---------------------- R = 4
Analysis procedure ------------------------------------------------------------------- Equivalent lateral force procedure
CODES AND STANDARDS
1. Building has been designed to, and shall be constructed in accordance with the following building codes and standards:
A. Pennsylvania Uniform Construction Code
B. 2009 International Building Code (IBC 2009)
C. 2009 International Existing Building Code (IEBC 2009)
D. ASCE 7-05, Minimum Design Loads for Buildings and Other Structures
E. ETL 11-18 Small Arms Range Design and Construction (19 April 2011)
2. Unless explicitly modified in the Contract Drawings and Specifications, the Contractor shall comply with provisions of:
A. ACI 301-08, Specifications for Structural Concrete
B. ACI 318-08, Building Code Requirements for Structural Concrete
C. ACI 530-08, Building Code Requirements for Masonry Structures
D. ACI 530.1-08, Specification for Masonry Structures
E. AISC 360-05, Specification for Structural Steel Buildings
F. AWS D1.1-04, Structural Welding Code - Steel
G. SJI 43rd Edition Standard Specifications and Load and Weight Tables for Steel
Joists and Joist Girders
GENERAL
1. All new construction shall comply with the Contract Documents and the Building Code.
2. Typical details and general notes apply to all parts of the work except where specifically detailed or unless otherwise noted.
3. The structural drawings illustrate structural members. Refer to architectural, mechanical, and electrical drawings for non-structural items which require special provisions during the construction of the structural members.
4. Drawings are not to be scaled.
5. Refer to architectural plans for floor depressions, openings, slopes, drains, curbs, pads, embedded items, non-bearing partitions, etc. Refer to mechanical and electrical plans for sleeves, openings, and hangers for pipes, ducts, and equipment.
6. The Contractor shall verify and be responsible for all dimensions and conditions which impact the work. Field verify sizes, elevations, hole locations, etc., prior to fabrication.
7. The Contractor shall carefully review the drawings to identify the scope of work required, visit the site to relate the scope of work to existing conditions and determine the extent to which those conditions and physical surroundings will impact the work.
8. Existing conditions as shown on these plans are for reference only. The Contractor is required to field verify all existing conditions prior to construction.
9. The Contractor shall resolve any conflicts on the drawings or in the specifications with the Architect/Engineer before proceeding with the work.
10. Any deviation, modification, or substitution from the approved set of structural drawings shall be submitted to the Owner, Architect, and Engineer for review/approval prior to its use or inclusion on the shop drawings.
11. The Contractor shall provide all necessary shores, braces, and guys required to support all loads to which the building structure and components, soils, other structures, and utilities may be subjected during construction. Shoring systems shall be designed, signed, and sealed by a professional engineer licensed in the jurisdiction where the project is located.
12. The Contractor shall provide means, method, techniques, sequence, and procedure of construction as required.
13. The Contractor shall protect all work, materials, and equipment from damage and shall provide proper storage facilities for materials and equipment during construction.
14. Site visits performed by the Architect/Engineer do not constitute inspections of means and methods of construction performed by the Contractor.
15. Structural observations performed by the Architect/Engineer during construction are not the continuous and special inspection services and do not waive the responsibility for the inspections required of the Building Department Inspector or the testing agency. Observations also do not guarantee the Contractor's performance and shall not be considered as supervision of construction.
16. The Contractor shall review shop drawings for completeness and compliance with contract documents. The Contractor shall stamp shop drawings prior to submission to the Architect and Engineer.
17. Review of the shop drawings by the Architect's Engineers shall not be construed as an authorization to deviate from the Contract Documents.
18. Shop drawings will not be processed if they are incomplete, lack coordination with relevant portion of contract documents, lack calculations if required, or if deviations, modifications, and substitutions are indicated without prior written approval from the
Architect/Engineer.
19. No pipes or ducts shall be embedded into structural members unless so shown on the plans or approved by the Engineer.
CONCRETE CONSTRUCTION
1. All concrete construction shall be in accordance with the latest Building Code
Requirements for Structural Concrete ACI 318 and ACI Detailing Manual, except that construction and removal of forms and reshoring shall be inspected by the
Contractor's engineer.
2. Reinforcing steel shall have the following minimum coverage. Place bars as near to the concrete surface as these minima permit wherever possible, unless noted otherwise:
A. Concrete poured against earth: 3"
B. Formed concrete in contact with earth: 2"
C. Exterior face of walls: 2"
D. All other wall faces, slabs, joists: 3/4" (#11 and smaller), 1 1/2" (#14 and #18)
3. Welded wire reinforcement for slabs on ground shall have a minimum top coverage of 1" and a maximum top coverage of 1 1/2", unless otherwise noted.
Reinforcement shall be positively supported and maintained in this position during placement of concrete.
4. Provide plastic-coated (not plastic-tipped) or stainless steel chairs in all concrete exposed to view in completed structure.
5. Construction joints shall be positioned so as not to change the structural design requirements. Framed floors and roofs shall have construction joints so that the ratio of length to width of a single pour shall not exceed 2. The location and size of all construction joints shall be approved by the Engineer. Submit proposed pour layout for Engineer's review and approval two weeks prior to placing concrete.
6. Welding of reinforcing bars (including tack welding) is not permitted without permission of Engineer in writing. Where and when permitted, welded rebars shall comply with ASTM A706 (Fy=60 ksi) and welding shall conform to AWS D1.4.
Welding shall be performed by certified welders.
7. All exposed corners of concrete beams, columns, walls, and steel members encased in concrete are to be chamfered 45°. Minimum chamfer to be 1/2".
8. Unless noted otherwise in project specifications or drawings, all exposed concrete subjected to freezing and thawing shall have a minimum cement content of 610 pounds per yard, a maximum water/cement ratio of 0.40, and 6%±1% of entrained air.
9. Drawings show typical reinforcing conditions. Contractor shall prepare detailed placement drawings of all conditions showing quantity, spacing, sizes, clearances, laps, intersections, and coverage required by the structural details, applicable code, and trade standards. Contractor shall notify reinforcing inspector of any adjustments from typical conditions which are proposed in placement drawings to facilitate field placement of reinforcing steel and concrete.
10. Bar bends shall be made cold. Bars shall not be bent after any portion of the bar is encased in concrete.
11. Splices (grade 60 deformed bars):
A. Lap all tension splices in accordance with the following tables. Provide Class
B Tension Lap Splices unless otherwise noted.
B. Increase tension or compression splice lengths by the following factors.
Increases are Cumulative:
1) Epoxy-coated bars: 1.5
D. Top bars are defined as horizontal bars with more than 12” of fresh concrete below.
LOOSE LINTEL SCHEDULE
1. Interior lintels shall be shop painted. Lintels exposed to weather shall be 3/8" minimum thickness and hot-dip galvanized.
2. Bottom plates in beam/plate assemblies shall be 1/2" less in width than the supported masonry wall. Stop bottom plates at face of masonry opening.
3. Weld bottom plates to lintels with continuous fillet welds (each side).
4. Steel lintels and lintel plates in exterior walls shall be fabricated, followed by hot-dip galvanizing of the complete assembly.
5. Lintels shall have minimum bearing at each end of 1" per foot of opening (6" minimum) except as detailed.
6. Lintels shall have 8" minimum solid masonry below bearing points and shall extend beyond the full bearing area.
7. Lintel bearing plates shall be held back 1/2" minimum from face of masonry at opening. Provide flexible caulk between lintel and masonry at this location. Match mortar color.
8. The following schedules apply to all non-bearing masonry walls and to bearing walls where lintels are not indicated on the structural drawings. See drawings for other lintels in bearing walls.
A. For 4", 8", 12", and 16" walls, provide one angle for each 4" of masonry wall thickness with 3 1/2" leg horizontal as follows:
Span Limits Angle Size
0'-0" to 4'-0" L3 x 3 1/2 x 1/4
4'-1" to 5'-6" L4 x 3 1/2 x 5/16
5'-7" to 7'-6" L5 x 3 1/2 x 5/16
7'-7" to 9'-6" L6 x 3 1/2 x 3/8
B. For 6" walls provide:
Span Limits Lintel Size
0'-0" to 4'-0" WT5x6
4'-1" to 5'-6" WT5x8.5
5'-7" to 9'-6" WT7x11 (interior)
STEEL CONSTRUCTION
1. Steel detailing, fabrication, and erection shall conform to the AISC Specification for
Structural Steel Buildings and Code of Standard Practice, and the AWS Structural
Welding Code.
2. Stresses occurring during fabrication, shipment, and erection shall be temporary and not excessive. Stresses at all times shall be less than design and allowable stresses. The full design and load-carrying capacity of the steel work shall not be impaired due to fabrication, shipment, or erection procedures. Throughout the complete process, the stability of all individual members and assembles shall be maintained.
3. The Contractor shall be responsible for the control of all erection procedures and sequences with relation to temperature differentials and weld shrinkage.
4. All additional steel required for erection purposes shall be provided at no additional cost and shall be removed unless approved by the Owner in writing.
5. Connections - welded or high strength bolted:
A. High-strength bolts shall be installed in accordance with "Specifications for
Structural Joints Using ASTM A325 or A490 Bolts".
B. A325SC or A490SC with hardened washers: use for all moment connections, wind connections, hangers, and other connections as noted on drawings.
C. A325N or A490N with hardened washers: use for all connections other than slip critical connections.
D. Provide hardened washers under nuts at all high-strength bolts, except where plate washers are used per AISC Specifications.
E. Unless snug tight connections are noted on the drawings as being permitted, all bolts should be tightened to full pretensioning load.
F. Use standard holes with the following exceptions: oversize holes are permitted when bolts are loaded in tension; short slotted holes are permitted for shear loading perpendicular to the slot.
G. Where minimum AISC fillet weld thickness requirement exceeds welds shown on details, or weld size is not specified, provide minimum AISC weld.
6. Welding electrodes shall be E70XX except where other electrodes are required for compatibility with material being welded.
7. All slip connections shall be provided with a means of preventing the nuts from unthreading.
8. Shop drawings are required and shall note type of electrodes, size of all welds, and type and size of all bolts. Shop drawings shall be prepared under the supervision of a professional engineer licensed in the jurisdiction where the project is located.
9. Primer, see specifications.
10. See all contract drawings for miscellaneous steel requirements.
11. All shop and field welding shall be performed by a recently certified welder.
12. All welding and high strength bolting must be inspected by a qualified testing laboratory. Laboratory shall be approved by the Architect and/or Engineer.
13. Do not weld to existing steel without written approval from the Engineer.
14. Provide 1/4" closure plates at all open ends of HSS members.
15. Miscellaneous hanging loads supported by steel members shall be applied in such a manner that no torsional forces are induced in the steel members, i.e., loads shall pass through the centerline of wide flange sections and through the shear center of channels.
STEEL JOIST CONSTRUCTION
1. Steel joist construction shall conform to the Standard Specifications and Code of
Standard Practice for Steel Joists and Joist Girders of the Steel Joist Institute, latest edition.
2. Provide steel joist end anchorage, bridging, and bridging anchorage in accordance with Standard Specifications of the Steel Joist Institute, latest edition. Weld steel joist bearing ends to steel supports or bearing plates.
3. When horizontal bridging is used at the top and bottom chords of steel joists, provide additional angle x-bridging as follows:
A. For bridging attached to masonry walls, provide additional angle x-bridging between the second, third, and fourth joists from exterior walls (second and third joist spaces).
B. For bridging attached to steel beams, provide additional angle x-bridging between the first, second, and third joists from spandrel beams (first and second joist spaces).
4. Provide header angles and double joists as required for openings. See structural and mechanical drawings.
5. Provide sloped end bearing where required.
6. In addition to the horizontal bridging required by the Steel Joist Institute for roof joists, provide a single line of bottom chord bridging near the first bottom chord panel point.
7. See drawings and specifications for uplift loads. Design joists and furnish bridging as required to resist and support uplift loads.
ABBREVIATIONS
@ At
ARCH. Architect or Architectural
BLDG. Building
BOTT. Bottom
BRG. Bearing
CANT. Cantilever
C.F.M.F. Cold Formed Metal Framing
C.J. Control Joint
CLR. Clear
CMU Concrete Masonry Unit
COL. Column
CONC. Concrete
CONN. Connection
CONST. Construction
CONT. Continuous
CONTR. Contractor
COORD. Coordinate
DET. Detail
DIA. or ø Diameter
DWG. Drawing
E.J. Expansion Joint
EL. Elevation
EMBED. Embedment
E.O.S. Edge of Slab
E.W. Each Way
EX. Existing
F.F.S. Frost-Free Slab
FTG. Footing
F.V. Field Verify
GA. Gauge or Gage
GALV. Galvanized
HORIZ. Horizontal
JT. Joint
MASY. Masonry
MAX. Maximum
MECH. Mechanical
MIN. Minimum
O.C. On Center
REF. Reference
REINF. Reinforcing or Reinforcement
REQD. Required
SECT. Section
SIM. Similar
S.O.G. Slab On Ground
TYP. Typical
VERT. Vertical
W/ With
WWR Welded Wire Reinforcement
DESIGN STRESSES
Concrete (strength design) minimum compressive strength in 28 days:
Topping Slab, Repair concrete (air-entrained)--------------------------------- f'c = 4,000 psi
Reinforcing bars (ASTM A615, Grade 60) ---------------------------------------------- Fy = 60,000 psi
Welded wire reinforcement (ASTM A185) ---------------------------------------------- fy = 70,000 psi
Structural steel W and S shapes
(ASTM A992 or ASTM A572/50) ------------------------------------------------ Fy = 50,000 psi
Structural steel other shapes (ASTM A36) --------------------------------------------- Fy = 36,000 psi
Anchor rods (F1554, Grade 36) unless otherwise noted --------------------------- Fy = 36,000 psi
Hollow structural sections (ASTM A500, Grade B)
Rectangular --------------------------------------------------------------------------- Fy = 46,000 psi
Steel joists (LH) ------------------------------------------------------------------------ min. Fy = 36,000 psi max. Fy = 50,000 psi
Masonry ----------------------------------------------------------------------------------------- f'm = 1,500 psi
Load-bearing CMU (ASTM C90)
Mortar (ASTM C270) --------------------------------------------------------------- Type M or S
Grout (ASTM C476) ---------------------------------------------------------------- 2,000 psi
Soil bearing pressure for foundations bearing strata (per As-Built Drawings)------------------------------------------ 2,000 psf
EX. 6"± CONC. S.O.G.
EX. 6"± CONC. S.O.G.
EX. 6"± CONC. S.O.G.
E X
.5
S
L O
P E
E X
.5
S
L O
P E
EX. C.J.
EX. C.J.
EX. C.J. EX. C.J.
EX. C.J.
EX. C.J.
E X
C
.J
E X
C
.J
E X
W
F
E X
W
F
E X
W
F
E X
C
.J
E X
C
.J
E X
C
.J
S L O
P E
EX. 8" CONC. CURB
EX. TRENCH
EX. 8" CONC. CURB
EX. 8" CONC. WALL
(TYP.)
EX. BULLET
TRAP
E X
W
F
EX. WF60
EX. WF24
EX. WF60 EX. WF60
E X
W
F
E X
W
F
A
8765432
EX. 4"± CONC. S.O.G.
E X
C
.J
E X
C
.J
E X
C
.J
E X
C
.J
E X
C
.J
E X
C
.J
E X
C
.J .5
S
L O
P E
S L O
P E
EX.
CP12x12
EF30 EX.
CP12x12
EX.
CP14x14
EX.
CP12x12
EX.
CP14x14
EX.
CP12x12
EX.
CP12x12
EF30
EF5040
EF30
EF5040
EF30 EF30
EF7030 EF7030 EX.
CP16x12
EX.
CP16x12
EX. 8" MASY. WALL
(TYP.)
1 4.1 5.1 9
B
A.5
B.1
10' - 4" ± 15' - 0" ± 15' - 0" ± 15' - 4" ± 15' - 4" ± 15' - 0" ± 15' - 0" ± 10' - 4" ±
9' - 4" ± 6' - 0" ±
4" ± 4" ±
3" CONC. TOPPING
W/ 6x6-W2.1xW2.1 WWR
SEE NOTE 2
3" CONC. TOPPING
W/ 6x6-W2.1xW2.1 WWR
SEE NOTE 2
JOINTS IN CONC. TOPPING
TO MATCH EX. C.J. (TYP.)
/4
S101
S101
OVERCUT NEW OPENING.
TOOTH 8" CMU INTO
EXISTING MASONRY AND
PROVIDE (1) #4 FULL
HEIGHT AT JAMB.
NOTES:
1. TOP OF EX. SLAB ON GRADE AT FIRING LINE ELEVATION AT 1156'-3 5/8". REFERENCE ELEVATION (0'-0")
TOP OF EX. CONCRETE FOOTINGS AT (-3'-0 5/8") U.O.N.
2. APPLY A BONDING ADHESIVE TO THE EXISTING SLAB ON GRADE PRIOR TO POURING THE TOPPING
SLAB. PRIOR TO APPLYING THE ADHESIVE, THE EXISTING SURFACE MUST BE CLEAN, STRONG, SATURATED SURFACE-DRY AND PREPARED IN ACCORDANCE WITH ICRI GUIDELINE NO. 310.2.
EX. SPREAD FOOTING
SCHEDULE
MARK SIZE
EF30
EF5040
EF7030
3'-0"x3'-0"x1'-0"±
5'-0"x4'-0"x1'-0"±
7'-0"x3'-0"x1'-0"±
EX. WALL FOOTING
SCHEDULE
MARK SIZE
EX. WF24 2'-0"x10"±
EX. WF36
EX. WF60
3'-0"x1'-0"±
6'-0"x1'-0"±
KEY PLAN
SMALL ARMS RANGE
RANGE BUILDING
AREA OF WORK
S.O.G.
(1156' - 3 5/8")
A
EX. CONC. S.O.G.
(SEE PLAN)
CONC. TOPPING SLAB
(SEE PLAN)
EX. CONC. S.O.G.
(SEE PLAN)
S.O.G.
(1156' - 3 5/8")
EX. CONC. S.O.G.
(SEE PLAN)EX. CONC. S.O.G.
(SEE PLAN)
CONC. TOPPING SLAB
(SEE PLAN)
EX. TRENCH DRAIN
EX. BULLET TRAP
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com
AE Works Project Number:
ARCHITECTS/ENGINEERS CONSULTANTS
Date
CheckedDrawn Sheet Number
Plate of
Project Number
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
CORAOPOLIS, PA 15108-5000
Sheet Name
Scale
As Indicated
16017
BARBER & HOFFMAN, INC.
Cranberry Twp., PA 16066-6409
(724) 741-0848/Fax (724) 741-0849 e-mail: bh@barberhoffman.com
215 Executive Drive, Suite 202
Consulting Engineers
FIRING RANGE COMPLEX, BUILDING 701
/1
/2
:5
:5
A
M
REPAIR SMALL ARMS RANGE
DZAQ 15-0001A/B
NJBRAJ S101
12/13/2016
FOUNDATION PLAN AND NOTES
NORTH
PROJECT
NORTH
TRUE
1/8" = 1'-0"
FOUNDATION PLAN
SECTION
1/2" = 1'-0"
1 SECTION
1/2" = 1'-0"
NO REVISIONS TO THIS SHEET.
05/10/17
SEAL
Revision# Date
AS-BUILT PROJECT RECORD DRAWING
1 RECORD DRAWINGS 05/10/17
SYMBOLS LEGEND
DESCRIPTION SYMBOL
DRAWING BLOCK TITLE MARK
ITEM SCALE
ITEM TITLE / DESCRIPTION
ITEM NUMBER / LETTER
WALL SECTION MARK
A101
SHEET NUMBER
SECTION IDENTIFIER
BUILDING SECTION MARK
A101
SHEET NUMBER
SECTION IDENTIFIER
DETAIL INDICATOR
A101
DETAIL IDENTIFIER
SHEET NUMBER
LEADER
DETAIL BOUNDARY
EXTERIOR ELEVATION MARK
A100
INTERIOR ELEVATION MARK
(SINGLE VIEW)
A100
INTERIOR ELEVATION MARK
(MULTIPLE VIEWS)
A100
ELEVATION IDENTIFIER
SHEET NUMBER
ELEVATION IDENTIFIER
SHEET NUMBER
ELEVATION IDENTIFIER
SHEET NUMBER
NORTH ARROW
NORTH
PROJECT
NORTH
TRUE
ROOM NAME
ROOM NUMBER
ROOM NAME INDICATOR
COLUMN GRID IDENTIFICATION
GRID LINE IDENTICATION
COLUMN GRID LINE
DOOR IDENTIFICATION
1 DOOR NUMBER
W#WINDOW IDENTIFICATION WINDOW / CURTAINWALL TYPE
WALL TYPE IDENTIFICATION
M8 WALL TYPE INDICATOR
WALL
KEYED NOTE IDENTIFICATION
REVISION IDENTIFICATION
REVISION CLOUD
REVISION NUMBER
DATUM POINT IDENTIFICATION
LEVEL
10'-0"
ELEVATION RELATIVE TO
FIRST FLOOR TOP OF SLAB
WALL FINISH PT#
FINISH
EXTENT OF FINISH
ROOM NAME
DEMO PLAN - KEYED NOTE
PLAN - KEYED NOTE
WALL SECTION / EXTERIOR ELEVATION - KEYED NOTE
EARTH -
COMPACTED FILL
GRAVEL, CRUSHED STONE
SAND, GROUT, LIMESTONE
WOOD, FINISH
WOOD, FRAMING
THROUGH MEMBER
WOOD, FRAMING
INTERRUPTED MEMBER
PLYWOOD
ACOUSTIC TILE
RIGID INSULATION
TAPERED
INSULATION
BATT INSULATION
CONCRETE
BRICK
CONCRETE BLOCK
STEEL
GYPSUM BOARD, PLASTER
MATERIALS LEGEND :
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com
AE Works Project Number:
ARCHITECTS/ENGINEERS
SEAL
Revision# Date
CONSULTANTS
Date
CheckedDrawn Sheet Number
Plate of
Project Number
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
CORAOPOLIS, PA 15108-5000
Sheet Name
Scale
As Indicated
/1
/2
:3 :3
P
M
REPAIR SMALL ARMS RANGE
FIRING RANGE COMPLEX, BUILDING 701
16017
DZAQ 15-0001A/B
PTRSJH A001
12/13/2016 164
AS-BUILT PROJECT RECORD DRAWING
ARCH SYMBOLS AND ABBREVIATIONS
SWBD SWITCHBOARD
SWGR SWITCHGEAR
SYM SYMMETRICAL TOP
T TOP
TA THROWAWAY
TAN TANGENT
TC TELECOMMUNICATIONS
CONTRACTOR
TCV TEMPERATURE CONTROL VALVE
TDV TRIPLE DUTY VALVE
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TG TONGUE & GROOVE
TH THERMOMETER
THRES THRESHOLD
TR TEMPERATURE RISE
TRANS TRANSITION
TRANSR TRANSFORMER
TSTAT THERMOSTAT
TV TURNING VANES OR TELEVISION
TYP TYPICAL
UC UNDER CABINET OR UNDER CUT
UFD UNDER FLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER'S LABORATORIES
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VAL VALVE
VD VOLUME DAMPER
VENT VENTILATION
VERT VERTICAL
VFS VENTURI FLOW STATION
VIF VERIFY IN FIELD
VL VENT LINE
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
W WATT
W/ WITH
W/O WITHOUT
WB WET BULB
WC WALL COVERING
WCL WATER CLOSET
WD WOOD
WF WIDE FLANGE
WFMD WATER FLOW MEASURING DEVICE
WG WALL GUARD OR WATER GAUGE
WHCH WHEEL CHAIR
WIN WINDOW
WMS WIRE MESH SCREEN
WP WEATHERPROOF
WPS WALL PROTECTION SYSTEM
WSCT WAINSCOT
WT WINDOW TREATMENT
WTD WATER TEMPERATURE DROP
WWF WELDED WIRE FABRIC
X DEMO
XN TO BE RELOCATED / NEW LOCATION
XR EXISTING TO REMAIN
ZVB ZONE VALVE BOX
ZVC ZONE VALVE CABINET
LTG LIGHTING
LV LOW VOLTAGE
LVR LOUVER
LWB LEAVING WET BULB
LWC LINEAR WOOD CEILING
LWT LEAVING WATER TEMPERATURE
MAN MANUAL
MAT MIXED AIR TEMPERATURE
MATL MATERIAL
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH ONE THOUSAND BTU / HOUR
MC MECHANICAL CONTRACTOR
MC METAL CLAD CABLE
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MO MASONRY OPENING
MOD MOTOR OPERATED DAMPER
MONO MONOLITHIC
MTD MOUNTED
MTG HT MOUNTING HEIGHT
MTL METAL
MTLH METAL HALIDE
MTR MOTOR
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
N/A NOT APPLICABLE
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NUMBER OR NORMALLY OPEN
NOM NOMINAL
NTS NOT TO SCALE
O OXYGEN
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OPER OPERATED
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PB PULL BOX
PC PLUMBING CONTRACTOR
PD PUMP DISCHARGE
PG PRESSURE GAUGE WITH COCK
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRD PRESSURE DIFFERENTIAL VALVE
PRELIM PRELIMINARY
PRT PRESSURE TAP
PRV PRESSURE REDUCING VALVE
PT PAINT OR POTENTIAL
TRANSFORMER
RO ROUGH OPENING
QT QUARRY TILE
R RADIUS
RA RETURN AIR / RELIEF AIR
RB RUBBER BASE
RC REMOVE COMPLETELY
RD ROOF DRAIN
RE RELOCATE EXISTING
REC RECESSED
RECPT RECEPTACLE
REF REFERENCE
REFL REFLECTOR
REG REGISTER
REINF REINFORCING
REM REMOVE
REQD REQUIRED
RET RETURN
REV REVISE
REX REMOVE EXISTING
RF RESILIENT FLOOR
RFI REQUEST FOR INFORMATION
RGS RIGID GALVANIZED STEEL CONDUIT
RH ROOF HATCH
RM ROOM
RN REMOVE AND REPLACE WITH NEW
RR REMOVE AND REPLACE
RS RAPID START
RV RELIEF VALVE
RWC RAIN WATER CONDUCTOR
SA SUPPLY AIR
SAN SANITARY SEWER ABOVE GROUND
SAN-BXR SANITARY SEWER - BURIED
EXISTING TO REMAIN
SAN-XR SANITARY SEWER ABOVE GROUND -
EXISTING TO REMAIN
SCHED SCHEDULE
SD SMOKE DAMPER OR SMOKE
DETECTOR
SDISP SOAP DISPENSER
SF SQUARE FOOT
SHT SHEET
SHT MTL SHEET METAL
SHTG SHEATHING
SIM SIMILAR
SM SURFACE MOUNTED
SNC SANITARY NAPKIN CABINET
SND SANITARY NAPKIN DISPOSER
SP STANDPIPE OR STATIC PRESSURE
SPC SPECIMEN PASS-THRU CABINET
SPEC SPECIFICATIONS
SPS STATIC PRESSURE SENSOR
SR SERVICE RECEPTOR
SS SOIL STACK
ST PR STATIC PRESSURE
ST STL STAINLESS STEEL
STD STANDARD
STER STERILIZER
STL STEEL
STOR STORAGE
STR STRAINER
STRUCT STRUCTURAL
SUSP SUSPENDED
SW SWITCH
ELEC CAB ELECTRICAL CABINET
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENTR ENTRANCE
EO ELECTRICAL OUTLET
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWB ENTERING WET BULB
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX EXAUST AIR
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
XP EXPLOSION PROOF
F/S FIRE / SMOKE DAMPER
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAT FINAL AIR TEMPERATURE
FB FIRE BLANKET
FC FLEXIBLE CONNECTION OR
FOOTCANDLE
FD FLOOR DRAIN OR FIRE DAMPER
FDN FOUNDATION
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FH FIRE HOSE
FHC FIRE HOSE CABINET
FHP FULL HEIGHT PARTITION
FHV FIRE HOSE VALVE
FIN FINISH
FIXT FIXTURE
FL FLOW LINE
FLA FULL LOAD AMPERES
FLASH FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLG C FLANGE CONNECTION
FLR FLOOR
FLUOR FLUORESCENT
FP FIRE PROOFING
FRMG FRAMING
FS FLOOR SINK
FSTOP FIRESTOPPING
FT FOOT / FEET
FT HD FEET OF HEAD
FTC FOOTCANDLES
FTG FOOTING
FUR FURRING
G GAS OR ELECTRICAL GROUND
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERATOR
GENL GENERAL
GFCI GROUND FAULT CIRCUIT
INTERRUPTOR
GL GLASS
GLV GLOBE VALVE
GND GROUND
GPM GALLONS PER MINUTE
GR GRADE
GRAV GRAVITY
GRD BM GRADE BEAM
GV GATE VALVE
GWB GYPSUM BOARD
H HIGH
HB HOSE BIB
HC HEATING CONTRACTOR
HDCP HANDICAP
HDR HEADER
HDW HARDWARE
HID HIGH INTENSITY DISCHARGE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSE POWER
HPD HIGH PRESSURE DRIP
HPF HIGH POWER FACTOR
HR HANDRAIL
HSKP HOUSEKEEPING
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VELOCITY
HVAC HEATING, VENTILATING, AIR
CONDITIONING
HW HOT WATER
HWD HARD WOOD
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HWS&R HOT WATER SUPPLY AND RETURN
HZ HERTZ
ID INSIDE DIAMETER
IER INVERTED ECCENTRIC REDUCER
IG ISOLATED GROUND
IME INSULATED METAL ENCLOSURE
IN INCH
INCAND INCANDESCENT
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
INTERL INTERLOCK
INV INVERT
ISO ISOLATION
IVS ISOLATED VALVE STATION
J-BOX JUNCTION BOX
JST JOIST
JT JOINT
KO KNOCK OUT
kVA KILOVOLT AMPERE kVAR KILOVAR (REACTANCE) kW KILOWATT kWH KILOWATT HOUR METER
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LB POUND
LDB LEAVING DRY BULB
LED LIGHT EMITTING DIODE
LF LINEAR FEET
LIN LINEAR
LOC LOCATION OR LOCATE
LPT LOW POINT
LSDC LINEAR SUPPLY DIFFUSER CEILING
LT LIGHT
& AND
A AIR (CLINICAL)
AAP ALARM ANNUNCIATOR PANEL
AAV AUTOMATIC AIR VENT
AB ANCHOR BOLT
ABV ABOVE
ACC DR ACCESS DOOR
ACFL ACCESS
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICAN DISABILITIES ACT
ADD ADDENDUM
ADDL ADDITIONAL
ADJ ADJUSTABLE
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AFMD AIR FLOW MEASURING DEVICE
AHU AIR HANDLING UNIT
AL ALIGN
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AP ACCESS PANEL
APC ARCHITECTURAL PRECAST
CONCRETE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASY ASYMMETRIC
ATC AUTOMATIC TEMPERATURE
CONTROL
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AWT AVERAGE WATER TEMPERATURE
BAT BATTERY
BC BALANCING COCK OR BARE COPPER
BDD BACKDRAFT DAMPER
BFC BELOW FINISH CEILING
BFE BOTTOM FOOTING ELEVATION
BFG BELOW FINISHED GRADE
BG BUMPER GUARD
BLDG BUILDING
BLKG BLOCKING
BLT BORROWED LIGHT
BLW BELOW
BM BEAM
BO BY OWNER
BOF BY OWNER FUTURE
BOT BOTTOM
BR BRICK
BRG BEARING
BRKR BREAKER
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT UP ROOFING
C CONDUIT
CAB CABINET
CANTL CANTILEVER
CAP CAPACITY
CATV CABLE TELEVISION
CCT CUBICLE CURTAIN TRACK
CCTV CLOSED CIRCUIT TELEVISION
CFH CUBIC FEET / HOUR
CFM CUBIC FEET / MINUTE
CH CHANNEL
CHK V CHECK VALVE
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CHWS&R CHILLED WATER SUPPLY AND
RETURN
CJ CONTROL JOINT
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CL CENTERLINE
CLG CEILING
CLG MTD CEILING MOUNTED
CLR CLR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUE / CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
COORD COORDINATE
CORR CORRIDOR
CPT CARPET OR CONTROL POWER
TRANSFORMER
CT CERAMIC TILE
CTR CENTER
CU COPPER
CV CONTROL VALVE
CW COLD WATER
D DEPTH OR DEEP
DB DRY BULB
dB DECIBEL
DCW DOMESTIC COLD WATER
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAILS
DF DRINKING FOUNTAIN
DHW DOMESTIC HOT WATER
DIA DIAMETER
DIAG DIAGONAL OR DIAGRAM
DIFF DIFFUSER
DIM DIMENSION
DISC DISCONNECT
DISCH DISCHARGE
DISP DISPENSER
DIST DISTRIBUTION
DIV DIVISION
DL DOWN LIGHT
DN DOWN
DP DISTRIBUTION PANEL
DPR DAMPER
DR DRAIN
DS DOWNSPOUT
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
EDB ENTERING DRY BULB
EF EXHAUST FAN
EIFS EXTERIOR INSULATION AND
FINISHING SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ABBREVATION LEGEND
1/8" = 1'-0"
TITLE
1 RECORD DRAWINGS 05/10/17
NO REVISIONS TO THIS SHEET.
05/10/17
UP UP
KEY PLAN
SMALL ARMS RANGE
RANGE BUILDING
AREA OF WORK
1 2 3 4 5 6 7 8 9
A
B
4.1 5.1
A.5
B.1
AD101
SMALL ARMS RANGE
SMALL ARMS RANGE
SMALL ARMS RANGE
PLATFORM
ELEC. CLOSET
8 8
1 2 3 4 5 6 7 8 9
A
B
4.1 5.1
A.5
B.1
PLATFORM
SMALL ARMS RANGE
SMALL ARMS RANGE
SMALL ARMS RANGE
ELEC. CLOSET
10'-4" ± 15'-0" ± 15'-0" ± 15'-4" ± 15'-4" ± 15'-0" ± 15'-0" ± 15'-0" ±
6'-0" ± 6'-0" ±
2' -0
5'
-1
1/ 2"
7'
-7
VIF VIF
V E
R
IF
Y T
H
IS
D
IM
E N
S
IO
N
6' -4
V
IF
1'
-8
1 1 1 1
2 2 2 222
GENERAL DEMOLITION NOTES
1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND COORDINATE ALL DEMOLITION
ACTIVITIES WITH ANY NEW CONSTRUCTION AS INDICATED WITHIN THE CONSTRUCTION DOCUMENTS.
DO NOT SCALE DRAWINGS.
2. CONTRACTOR SHALL PERFORM ALL NECESSARY DEMOLITION ACTIVITIES AS REQUIRED FOR
INSTALLATION OF NEW CONSTRUCTION AS INDICATED WITHIN THE CONSTRUCTION DOCUMENTS.
COORDINATE WITH THOSE DOCUMENTS FOR EXACT DIMENSIONS AND LOCATIONS OF FINISHED
WORK.
3. ALL DEMOLITION NOT SPECIFICALLY INDICATED, BUT NECESSARY TO COMPLETE THE PROJECT AS
INDICATED ON THE CONSTRUCTION DOCUMENTS, SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
4. CONTRACTOR SHALL INSPECT AND ACCESS EACH SPACE AND FULFILL THE INTENT OF THE WORK REQUIRED BY THE CONTRACT DOCUMENTS. DEVIATIONS REQUIRED BY EXISTING FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
5. ANY CUTTING AND REMOVAL INDICATED ON THE CONSTRUCTION DOCUMENTS ARE GENERAL
INDICATIONS ONLY AND MAY NOT NECESSARILY SHOW THE FULL EXTENT OF CUTTING AND REMOVAL
NECESSARY.
6. THROUGHOUT THE COURSE OF DEMOLITION ACTIVITIES, PROPERLY PROTECT ANY EXISTING
CONSTRUCTION INDICATED TO REMAIN. EXERCISE CARE WHEN REMOVING ADJACENT
CONSTRUCTION AND PROPERLY REPAIR (TO ORIGINAL CONDITION) ANY AREAS SCHEDULED TO
REMAIN THAT SUSTAIN DAMAGE AS A RESULT OF DEMOLITION ACTIVITIES.
7. CONTRACTOR SHALL CONSTRUCT DUST PROOF PROTECTIVE BARRIERS AS NECESSARY AT AREAS OF INTERIOR DEMOLITION TO PROTECT EXISTING CONSTRUCTION AND EQUIPMENT SCHEDULED TO
REMAIN.
8. CONTRACTOR SHALL PERFORM ALL WORK REQUIRED TO PROTECT EXISTING BUILDING UTILITIES.
9. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL NECESSARY TEMPORARY BRACING AND SHORING AS REQUIRED TO MAINTAIN THE INTEGRITY AND STRUCTURAL STABILITY OF THE BUILDING
AND ITS INDIVIDUAL ELEMENTS.
10. EXCEPT AS NOTED OTHERWISE, CONTRACTOR SHALL REMOVE ALL DEMOLISHED MATERIALS
FROM THE SITE AND DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL LAWS
REGULATIONS. DO NOT BURN, BURY, OR SELL MATERIALS ON THE PROJECT SITE. AT THE
COMPLETION OF EACH WORK DAY, CONTRACTOR SHALL CLEAN THE ENTIRE WORK AREA AND LEAVE
IN A NEAT CONDITION FREE OF DEBRIS AND RUBBISH.
11. STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND CIVIL DOCUMENTS PROVIDE
ADDITIONAL DEMOLITION REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
DOCUMENTS THAT MAY PROVIDE ADDITIONAL DEMOLITION REQUIREMENTS BEYOND THOSE
SPECIFICALLY INDICATED ON THE ARCHITECTURAL DEMOLITION PLANS.
12. CONTRACTOR SHALL CAREFULLY REMOVE AND DELIVER TO THE OWNER ANY EXISTING FIRE
EXTINGUISHERS OR OTHER IDENTIFIED ITEMS FOUND WITHIN THE LIMIT OF DEMOLITION ACTIVITIES.
13. OWNER RESERVES THE RIGHT TO REMOVE ITEMS SCHEDULED FOR DEMOLITION PRIOR TO THE
START OF DEMOLITION ACTIVITIES AND MAY CLAIM ANY ITEMS REMOVED BY THE CONTRACTOR
THROUGHOUT THE COURSE OF DEMOLITION.
ADDITIONAL DEMOLITION SCOPE (NOT ILLUSTRATED)
1. CONTRACTOR SHALL CAREFULLY REMOVE ALL PORTIONS OF THE TARGET RETRIEVAL SYSTEM
(TRS) THAT MAY BE DAMAGED DURING CONSTRUCTION FROM ALL FIRING LANES.
2. PRIOR TO REMOVAL OF TRS, CONTRACTOR SHALL TEST TRS FOR PROPER OPERATION AND
REPORT ANY DEFICIENCIES OR MALFUNCTIONS TO OWNER VIA CONTRACTING OFFICER. ANY
DEFICIENCIES OR MALFUNCTIONS, OTHER THAN CABLES OR RUSTED COMPONENTS AND MOUNTING HARDWARE OF TRS OR ITS SUSPENSION SYSTEM, REPORTED PRIOR TO REMOVAL OF THE SYSTEMS MAY BE REPAIRED UNDER AN IN-SCOPE MODIFICATION TO THIS CONTRACT IF FUNDS ARE AVAILABLE
AND WORK VIA MODIFICATION IS CONSIDERED IN THE GOVERNMENT’S BEST INTEREST.
3. CONTRACTOR SHALL STORE TRS FOR REINSTALLATION AFTER COMPLETION OF ALL WORK ON
BAFFLES AND SUPPORTING STRUCTURES.
4. CONTRACTOR SHALL STORE REMOVED SYSTEMS OFF SITE OR IN CONTRACTOR-PROVIDED
CONTAINERS ON-SITE.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO TRS BEYOND THAT WHICH WAS
INITIALLY REPORTED ONCE TRS IS REMOVED. UPON COMPLETION OF PROJECT, CONTRACTOR
SHALL REINSTALL EXISTING TRS.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com
AE Works Project Number:
ARCHITECTS/ENGINEERS
SEAL
Revision# Date
CONSULTANTS
Date
CheckedDrawn Sheet Number
Plate of
Project Number
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
CORAOPOLIS, PA 15108-5000
Sheet Name
Scale
As Indicated
/1
/2
:3 :4
P
M
REPAIR SMALL ARMS RANGE
FIRING RANGE COMPLEX, BUILDING 701
16017
DZAQ 15-0001A/B
PTRSJH AD101
12/13/2016 165
AS-BUILT PROJECT RECORD DRAWING
DEMOLITION FLOOR PLAN
NORTH
PROJECT
NORTH
TRUE
1/8" = 1'-0"
DEMOLTION PLAN
1/4" = 1'-0"
ENLARGED DEMOLITION PLAN
KEYED DEMOLITION NOTES
# NOTE
1 CORE DRILL EXISTING MASONRY WALL TO ACCOMMODATE SEASONAL HEATING DUCT; FINAL LOCATION OF PENETRATIONS TO BE
APPROVED BY OWNER PRIOR TO BEGINNING WORK
2 MODIFY EXISTING WOODEN SHELF BY REMOVING FAN-OBSTRUCTION PORTION; PATCH AND REPAIR WALL AND FLOOR AS
REQUIRED
3 PREPARE EXTERIOR SIDE OF CAST-IN-PLACE CONCRETE WALL TO RECEIVE NEW FINISH (TYP)
4 SAWCUT EXISTING MASONRY WALL AND PREPARE TO RECEIVE NEW CONSTRUCTION; REFER TO STRUCTURAL DRAWINGS FOR
DEMO AND NEW WORK FOR NEW OVERHEAD COILING DOOR OPENING
5 REMOVE EXISTING DOOR AND FRAME; PREPARE OPENING TO RECEIVE NEW WORK
6 REMOVE EXISTING GUTTER AND DOWNSPOUT; PATCH AND REPAIR ANY AREAS DAMAGED OR DISTURBED FROM REMOVAL OF
FASTENERS
7 REMOVE EXISTING ACOUSTICAL QUILTS THROUGHOUT BULLET TRAP AREA
8 REMOVE (AND SALVAGE TO EXTENT POSSIBLE) ALL ACOUSTICAL WALL PANELS THROUGHOUT; CLEAN AND PREPARE PANELS DEEMED ACCEPTABLE BY OWNER FOR REINSTALLATION; REMOVE ANY REMAINING MASTIC AND CLEAN AND PREPARE SURFACE
TO RECEIVE NEW CONSTRUCTION
9 REMOVE (AND SALVAGE TO EXTENT POSSIBLE) ALL RUBBER BALLISTIC FLOOR PANELS THROUGHOUT; SET ASIDE PANELS DEEMED ACCEPTABLE BY OWNER FOR FUTURE USE; REMOVE ANY REMAINING MASTIC AND CLEAN AND PREPARE SUBSTRATE
TO RECEIVE NEW CONCRETE TOPPING
10 SAWCUT EXISTING CONCRETE FLOOR AT NEW OPENING AND PREPARE FOR SLOPED ENTRY (APPROXIMATELY 8'-4" X 1'-2")
UP UP
1 2 3 4 5 6 7 8 9
A
B
4.1 5.1
A.5
B.1
SMALL ARMS RANGE
ELEC. CLOSET
PLATFORM
SMALL ARMS RANGE
A101
HATCHED REGION INDICATES EXTENT
OF NEW 3" CONCRETE TOPPING
HATCHED REGION INDICATES EXTENT
OF NEW 3" CONCRETE TOPPING
P R
IM
E
A N
D P
A
IN
T E
X T
E R
IO
R
C A
S T
-I N
-P
LA
C E
C O
N C
R E
T E
W A
LL
S
'-5
/2
V
IF
P R
IM
E
A N
D P
A
IN
T E
X T
E R
IO
R
C A
S T
-I N
-P
LA
C E
C O
N C
R E
T E
W A
LL
S
8 99 8 10
12 12
7 7 77
1 2 3 4 5 6 7 8 9
A
B
4.1 5.1
A.5
B.1
PLATFORM
SMALL ARMS RANGE
SMALL ARMS RANGE
ELEC. CLOSET
HATCHED REGION INDICATES EXTENT OF
NEW 3" CONCRETE TOPPING;
REFER TO FULL FLOOR PLAN FOR
ADDITIONAL RELATED SCOPE
NEW CEILING GRID AND ACOUSTICAL TILES
(BETWEEN COLUMN LINES A AND B, 1 AND 9)
EXCLUSIVE OF PLATFORM ROOM 103;
REFER TO REFLECTED CEILING PLAN ON A102
SMALL ARMS RANGE
HATCHED REGION INDICATES EXTENT OF
NEW 3" CONCRETE TOPPING;
REFER TO FULL FLOOR PLAN FOR
ADDITIONAL RELATED SCOPE
1 1 1
2 2 2 222
TYP
777 7
GENERAL PROJECT NOTES
1. ALL CONSTRUCTION WORK SHALL CONFORM WITH THE APPLICABLE CODES AND ORDINANCES OF THE LOCAL JURISDICTION, THE COMMONWEALTH OF PENNSYLVANIA, AND THE CURRENT ADOPTED VERSION OF THE INTERNATIONAL BUILDING CODE FAMILY. THE CONTRACTOR SHALL POST NOTICES AND COMPLY WITH THE
GOVERNING LAWS OF THE JURISDICTION.
2. INSTALLATIONS PERFORMED IN CONNECTION WITH THESE DRAWINGS SHALL COMPLY WITH THE MOST RECENT
NFPA EDITION.
3. THE SITE WORK SHALL BE PROPERLY SUPERVISED BY THE CONTRACTOR'S JOB SITE SUPERINTENDENT.
SUFFICIENT PERSONNEL SHALL BE EMPLOYED TO COMPLETE THE WORK WITHIN THE CONTRACTED TIME. PERSONNEL
SHALL BE SKILLED IN THE TASK ASSIGNED.
4. THE CONTRACTOR SHALL, AT ALL TIMES, MAINTAIN ADEQUATE PROTECTION TO SAFEGUARD THE PUBLIC AND ALL
PERSONS ENGAGED IN THE PERFORMANCE OF THE WORK.
5. THE DRAWINGS REFLECT CONDITIONS AS CAN BE INFERRED FROM VISIBLE CONDITIONS, OR FROM DRAWINGS AND INFORMATION FURNISHED BY THE OWNER, BUT CANNOT BE GUARANTEED. THE CONTRACTOR SHALL VERIFY ALL GRADES, LINES, LEVELS AND DIMENSIONS INDICATED ON THE DRAWINGS AND SHALL REPORT ALL INCONSISTENCIES TO THE ARCHITECT PRIOR TO THE EXECUTION OF THE WORK. RECHECK ALL DIMENSIONS PRIOR TO ORDERING
MANUFACTURED AND/OR FABRICATED ITEMS.
6. PLAN DIMENSIONS, UNLESS NOTED OTHERWISE, ARE TO THE FACE OF THE WALL FINISH OR CENTERLINE OF
COLUMN.
7. ALL INDICATIONS OF MASONRY ARE SHOWN IN ACTUAL DIMENSIONS (NOT NOMINAL), UNLESS NOTED
OTHERWISE.
8. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR PROTECTION AND SAFEKEEPING OF PRODUCTS PURCHASED FOR THIS PRODUCT AND STORED ON THE PROJECT SITE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ON PREFERRED LOCATIONS FOR STORED MATERIALS ON THE PROJECT SITE, IF ALLOWED AS PART OF THE
REQUIREMENTS OF THIS PROJECT.
9. THE CONTRACTOR SHALL MAINTAIN AREAS UNDER THE CONTRACTOR'S CONTROL TO BE FREE OF WASTE MATERIALS, DEBRIS, AND RUBBISH. CONTAINERS FOR DEPOSIT OF DEBRIS AND RUBBISH SHALL BE PROVIDED BY THE CONTRACTOR. COORDINATE LOCATION OF CONTAINERS WITH THE OWNER'S REPRESENTATIVE PRIOR TO PLACEMENT.
REMOVE AND DISPOSE OF DEMOLITION MATERIAL OFF SITE IN ACCORDANCE WITH APPLICABLE CODES AND/OR
SPECIFICATIONS.
10. EXTRANEOUS MATERIALS SHALL BE PERIODICALLY REMOVED, AND AT THE CONCLUSION OF THE PROJECT.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL FIRESAFING/FIRESTOPPING MATERIALS AT ALL THROUGH-WALL AND THROUGH-CEILING PENETRATIONS AS REQUIRED FOR THE CONSTRUCTION WORK AND TO MAINTAIN FIRE RATINGS OF FLOORS AND WALLS. MATERIALS AND INSTALLATION DETAILS SHALL
CONFORM TO UNDERWRITER LABORATORIES LISTING FOR RATED ASSEMBLIES.
12. ALL WOOD FRAMING AND SHEATHING SHALL BE FIRE RETARDANT TREATED AS REQUIRED BY THE BUILDING CODE
CLASSIFICATION OF 'NONCOMBUSTIBLE'.
13. DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. NOTIFY THE ARCHITECT OF ANY DEVIATIONS OR DISCREPANCIES FOUND & RECEIVE DIRECTION BEFORE PROCEEDING.
14. ALL REVISIONS TO THE DRAWINGS MUST PROCEED THROUGH THE ARCHITECT. OWNER/CONTRACTOR REVISIONS
MAY BE CONSIDERED INVALID.
15. THE CONTRACTOR IS RESPONSIBLE FOR COMPARING AND COORDINATING ALL DRAWINGS FOR PROPER FIT AND ATTACHMENT OF ALL PARTS. DETAILS NOT SHOWN OR DESCRIBED IN THESE NOTES SHALL BE CONSTRUCTED TO SAME SIZE AND CHARACTER AS FOR SIMILAR CONDITIONS WHICH ARE SHOWN, SPECIFIED, OR COMMONLY
CONSTRUCTED IN THE INDUSTRY.
16. NO STRUCTURAL MEMBER SHALL BE OMITTED, NOTCHED, CUT, BLOCKED OUT, OR RELOCATED WITHOUT PRIOR
APPROVAL BY THE ARCHITECT OR ENGINEER.
17. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES
DURING CONSTRUCTION.
18. ALL TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO SUSTAIN ALL CONSTRUCTION LOADS, SOIL
PRESSURE, LATERAL AND OTHER LOADS TO WHICH THE STRUCTURE MAY BE SUBJECTED.
19. CONTRACTOR SHALL COORDINATE LOCATIONS OF LIGHT FIXTURES, REGISTERS, ETC. WITH THE REFLECTED
CEILING PLAN LAYOUT.
20. ALL DIFFUSERS AND REGISTERS SHALL BE CENTERED WITH SUSPENDED ACOUSTICAL PANELS, UNLESS NOTED
OTHERWISE ON DRAWINGS.
21. ALL VOIDS IN MASONRY, CONCRETE AND OTHER ASSEMBLIES CREATED AROUND PENETRATIONS SHALL BE
FILLED/PATCHED WITH CONSTRUCTION TO MATCH SURROUNDING CONDITIONS.
22. CONTRACTOR IS RESPONSIBLE FOR PAINTING ALL EXPOSED STEEL, DECKING, PIPING, CONDUIT, AND DUCTS WHICH ARE EXPOSED IN AREAS WITH NO CEILINGS AND SCHEDULED TO RECEIVE PAINT FINISH AS INDICATED ON
THE FINISH SCHEDULE.
23. THE TWO-PART BAFFLE SYSTEM IS COMPRISED OF A 3/8" THICK AR500 STEEL PLATE ADHERED TO 2" THICK BALLISTIC RUBBER AND DESIGNED TO CAPTURE AND ENCAPSULATE AMMUNITION UP TO 7.62mm CALIBER.
KEY PLAN
SMALL ARMS RANGE
RANGE BUILDING
AREA OF WORK
ADDITIONAL SCOPE (NOT ILLUSTRATED)
1. REFER TO HAZARDOUS MATERIAL ABATEMENT SPECIFICATION SECTION FOR LEAD ABATEMENT RELATED SCOPE, INCLUDING ABATEMENT OF LEAD DUST, LEAD BULLET FRAGMENTS AND LEAD CONTAINING SURFACE COATINGS.
2. PREPARE AND PAINT EXISTING-TO-REMAIN TRUSSES BETWEEN FIRING RANGE AND FRONT OF BULLET TRAP.
S.O.G.
0' - 0"
TOP/ EX. WALL
10' - 0"
AB
8' -0
V
IF
4' -0
9' -4
/4
6" ACOUSTICAL BATT
INSULATION
EXISTING REINSTALLED
LIGHT FIXTURE WITH
PENDANT ARMATURE
EXTENDED THROUGH
CEILING
EXISTING HEATERS
TO REMAIN
EXISTING SUPPLY FAN AND
LOUVER TO REMAIN
SECURELY FASTEN METAL
CHANNEL AND BRACKET
TO EXISTING SOFFIT
EXISTING EXHAUST
FANS TO REMAIN
NEW
EXHAUST
GRILLE
MODIFIED SHELF LEDGE
AND SUPPORT BRACKET
(BEYOND)
8'
- 0
M
IN
TARGET LINE
EXISTING STRUCTURAL FRAMING
MEMBERS TO REMAIN; REFER TO
STRUCTURAL DRAWINGS
NEW STRUCTURAL FRAMING MEMBERS
(TYP); REFER TO STRUCTURAL
DRAWINGS FOR TYPE AND EXTENT
BALLISTIC BAFFLES (TYP) -
REFER TO STRUCTURAL
AND BAFFLE DRAWINGS
EXISTING ACOUSTICAL
BAFFLE TO REMAIN
A101
NEW INTER-BAFFLE LIGHT
FIXTURE (TYP) - REFER TO
LIGHTING DRAWINGS
OVERLAP
6" MIN.
FIRING LINE
(TYPICAL)
C-CHANNEL SUPPORT BRACKET
AS REQUIRED
WEATHER-RESISTANT
SEALANT AND BACKER ROD
6" ACOUSTICAL BATT INSULATION
SUSPENSION CEILING MFR
APPROVED SUPPORT BRACKET -
APPLY WEATHER-RESISTANT PAINT
TO MATCH EXISTING METAL PANELS
(ABOVE)
EXISTING METAL
PANEL TO REMAIN
B
REMOVABLE VENT CAP FASTENED
WITH MASONRY SCREWS
COORDINATE MASONRY CORE DRILLING
WITH MECHANICAL CONTRACTOR TO
ACCOMMODATE NEW DUCT PENETRATION
WITH MECH CONTRACTOR
COORDINATE WIDTH
REMOVABLE GALVANIZED METAL
COVER PLATE AND INSECT SCREEN
EXISTING EXTERIOR WALL
INTERIOR
EXTERIOR
M
A T
C H
H E
IG
H
T O
F E
X
IS
T
IN
G L
E D
G E
3' -1
0"
H E
IG
H
T O
F H
O R
IZ
O
N T
A L
S U
R F
A C
E
EXISTING EXTERIOR WALL
HORIZONTAL WOODEN SURFACE
(PAINT TO MATCH EXISTING)
MECHANICALLY FASTENED
SUPPORT BRACKET, AS
REQUIRED FOR SECURE
CONNECTION
NOTE:
FINISH MODIFIED/CUT EDGE
TO MATCH EXISTING TO
REMAIN SHELF LEDGE.
PRIME/PAINT ALL
NEW/EXPOSED WOOD TO
MATCH EXISTING SHELF
LEDGE.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com
AE Works Project Number:
ARCHITECTS/ENGINEERS
SEAL
Revision# Date
CONSULTANTS
Date
CheckedDrawn Sheet Number
Plate of
Project Number
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
CORAOPOLIS, PA 15108-5000
Sheet Name
Scale
As Indicated
/1
/2
:3 :4
P
M
REPAIR SMALL ARMS RANGE
FIRING RANGE COMPLEX, BUILDING 701
16017
DZAQ 15-0001A/B
PTRSJH A101
12/13/2016 166
AS-BUILT PROJECT RECORD DRAWING
FLOOR PLAN AND TYPICAL SECTION
NORTH
PROJECT
NORTH
TRUE
1/8" = 1'-0"
GROUND LEVEL PLAN
1/4" = 1'-0"
ENLARGED GROUND LEVEL PLAN
1/4" = 1'-0"
ENLARGED TYPICAL SECTION
1 1/2" = 1'-0"
SUSPENSION CEILING GRID SUPPORT BRACKET
1 1/2" = 1'-0"
EXTERIOR WALL PENETRATION (TYP)
1 1/2" = 1'-0"
CASEWORK MODIFICATION DETAIL
KEYED PLAN NOTES
# NOTE
1 AT NEW PENETRATION, PROVIDE VENT CAP ON INTERIOR SIDE AND REMOVABLE GALVANIZED METAL COVER PLATE ON EXTERIOR
SIDE; REFER TO DETAIL 5/A101
2 MODIFIED SHELF LEDGE WITH BRACKETS MOUNTED AT 46" A.F.F.; ROUTE AROUND EXISTING WALL-MOUNTED CONDUITS AS
REQUIRED
3 PRIME AND PAINT EXTERIOR SIDE OF CAST-IN-PLACE CONCRETE WALLS; REFER TO 1/A101 FOR EXTENT OF WORK AND MATCH
EXISTING COLOR UNLESS REQUESTED OTHERWISE BY OWNER
4 NEW 8' WIDE OVERHEAD COILING DOOR; REFER TO DOOR DETAILS ON A601
5 PROVIDE STEEL LINTEL AS REQUIRED BY OHC DOOR MANUFACTURER AND STRUCTURAL DRAWINGS
6 APPROXIMATE LOCATION OF NEW CONCRETE PAD (NIC)
7 NEW / SALVAGED ACOUSTICAL RUBBER WALL PANELS (TYP THROUGHOUT HATCHED REGION)
8 PROVIDE NEW DOWNSPOUT, RAIN BOOT, AND PIPING TO EXISTING STORM WATER TRENCH
9 NEW 6" x 6" GUTTER ASSEMBLY WITH 1/8TH INCH PER FOOT SLOPE MINIMUM
10 CONNECT NEW DOWNSPOUT TO EXISTING BOOT
11 INSTALL NEW ACOUSTICAL QUILT MATERIAL MATCHING TYPE AND LAYOUT OF REMOVED PIECES; INSTALL PER MANUFACTURER
REQUIREMENTS
12 NEW 3" CONCRETE TOPPING THROUGHOUT HATCHED REGION; PRIOR TO PLACING NEW CONCRETE, SCARIFY AS REQUIRED AND PREPARE SURFACE TO RECEIVE NEW TOPPING BY REPAIRING ALL CRACKED, SPALLED, OR OTHERWISE DAMAGED CONCRETE
FLOORING WHERE APPLICABLE
13 SLOPE CONCRETE FLOOR AT NEW OHC DOOR ENTRY
1 2 3 4 5 6 7 8 9
A
B
4.1 5.1
A.5
A101
10'-0" 14'-0" 16'-0"14'-0" 14'-0" 8'-0"
9' - 4" 9' - 4"
5'-3" ± 9'-11 1/2" 9'-10" 10'-0" 10'-0" 10'-4" 10'-4" 10'-0" 10'-0" 10'-0" 10'-0" 5'-0 1/2" ±
6'-8 3/8" 10'-0" 10'-0" 10'-0" 10'-0" 10'-8" 10'-0" 10'-0" 10'-0" 10'-0" 9'-0" 1'-0 3/8"
APPROXIMATE SPACING FOR NEW LIGHT FIXTURES
(REFER TO LIGHTING SHEETS FOR DETAILS)
APPROXIMATE SPACING FOR REINSTALLED LIGHT
FIXTURES (REFER TO LIGHTING SHEETS FOR DETAILS)
T
IL
E F
U
LL
TILE
FULL
TILE
FULL
KEY PLAN
SMALL ARMS RANGE
RANGE BUILDING
AREA OF WORK
SUPPLY AIR DIFFUSER
RETURN AIR GRILLE
EXHAUST GRILLE
PENDANT-MOUNTED HEATER (RELOCATED EXISTING UNIT;
PENDANT MOUNTING HARDWARE EXTENDS THROUGH
SUSPENDED ACT CEILING)
LIGHT FIXTURE (RELOCATED EXISTING FIXTURE; PENDANT
MOUNTING HARDWARE EXTENDS…
This is the start of the file's text. The full file is on GovTribe.