508Grand_Coulee_Fire_Station_amd_002.pdf

PDF 2 MB Posted

Attached to
Grand Coulee Fire Station Federal contract opportunity
Solicitation number
R16PS00508
Issued by
Department of the Interior Bureau of Reclamation

About this file

Replacement Pages - Amendment 0002

View the file

Other files for this federal contract opportunity

Other files attached to Grand Coulee Fire Station, newest first.
File Type Posted
Sol_R16PS00508_Amd_000005.pdf PDF
Sol_R16PS00508_Amd_000004.pdf PDF
R16PS00508__-_Pre-Bid_Construction_Meeting_Attendance.pdf PDF
SF_30_Amend_3.pdf PDF
R16PS00508-Amend_1_COMPLETE.pdf PDF
SF-30_Amend_2.pdf PDF
508_Grand_Coulee_Fire_Station_amd_002_drawings.pdf PDF
0508_Grand_Coulee_Fire_Station_drawings.pdf PDF
R16PS00508_Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation No. R16PS00508 Grand Coulee Fire Station

Amendment No. 002

Metal Gratings 05 53 00 - 2

3. National Association of Architectural Metal Manufacturers (NAAMM):

a. MBG 531, Metal Bar Grating Manual.

b. MBG 532, Heavy-Duty Metal Bar Grating Manual.

1.05 SUBMITTALS

A. Action Submittals:

1. RSN 05 53 00-1, Shop Drawings:

a. Grating: Show dimensions, weight, size, and location of connections to adjacent grating, supports, and other Work.

b. Grating Anchorage: Show details of anchorage to supports to prevent displacement from traffic impact.

c. Product data for grating, grating clips, anchors, accessories, and other manufactured products specified herein.

d. Manufacturer’s specifications, including coatings, surface treatment, and finishes.

B. Informational Submittals:

1. RSN 05 53 00-2, Special handling and storage requirements.

2. RSN 05 53 00-3, Installation instructions.

1.06 DELIVERY, STORAGE, AND HANDLING

A. Insofar as is practical, factory assemble items.

B. Package and clearly tag parts and assemblies that are, due to necessity, shipped unassembled.

PART 2 PRODUCTS

2.01 GENERAL

A. Or equal products shall meet the salient characteristics identified herein for that product.

2.02 GRATING MATERIALS

A. Carbon Steel:

1. Bearing Bars, Banding, and Rectangular Cross Bars: ASTM A1011/ A1011M commercial steel Type II for hot rolled carbon steel sheet and strip, or ASTM A36/A36M.

2. Cross Bars made from Wire Rods: Not Permitted.

3. Finish: Unfinished unless noted otherwise.

B. Stainless Steel:

Amendment No. 002

Metal Gratings 05 53 00 - 3

1. Bearing Bars, Banding and Cross Bars: ASTM A666, Type 304L

2. Finish: Stainless Steel Mill Finish No. 2. Tread Material shall meet

Stainless Steel Mill Finish No. 4

2.03 METAL BAR GRATING

A. General Requirements:

1. Maximum Service Load:

a. Light Duty: 100 psf uniformly distributed load.

2. Maximum Deflection: Span/240 or 1/4 inch, whichever is less.

3. Bearing Bar Spacing:

a. Light Duty: 1-3/16 inch maximum, center-to-center.

4. Cross Bar Spacing: 2 inches maximum, center-to-center.

5. Bearing Bars, Cross Bars and Banding: Minimum thickness as specified in NAAMM MBG 531 or as shown on Drawings.

B. Grating Materials: Welded, rectangular bar grating fabricated by electro-forging cross bars to bearing bars.

C. Surface: Plain.

2.04 ENTRY FLOOR GRILLS STAINLESS STEEL GRATING

A. General Requirements:

1. Maximum Service Load:

a. 500 psf uniformly distributed load.

b. Rolling load of 800 pounds per wheel at 50 passes with no visible damage or permanent deflection.

2. Tread material: Type 304 stainless steel 0.071” x 0.177” surface wires spaced with a 0.125” slot opening and resistance welded to 1” Type 304 stainless steel support bars spaced at 1” oc.

3. Hidden lockdowns to secure grating spaced at no more than 2’0” on center.

4. Fabricated embedded frames and bars at perimeter of grating units.

B. Manufacturers and Products:

1. Kadee Industries, http://www.kadeeindustries.com; KD98 Stainless Steel Grating

2. Activar, Inc, http://www. activar.com; JL-500 Series Stainless Steel Floor Grating.

3. Nystrom, http://www.nystrom.com; eleGRIL.

4. Or equal.

2.05 HEAVY-DUTY METAL BAR GRATING

A. General Requirements:

http://www.kadeeindustries.com/ http://www/

Amendment No. 002

Metal Gratings 05 53 00 - 4

1. Maximum Service Load: AASHTO H-20.

2. Maximum Deflection: Span/240.

3. Bearing Bar Spacing: 1-7/8 inch maximum center-to-center.

4. Cross Bar Spacing: 4 inches maximum center-to-center.

5. Bearing Bars, Cross Bars and Banding: Minimum thickness as specified in NAAMM MBG 532 or as shown on Drawings.

6. Grating Type: Heavy-duty, rectangular bar grating fabricated by welding crossbars between rectangular bearing bars.

2.06 ACCESSORIES

A. Embedded Frames: As indicated on Drawings and as specified in Section 05 50 00, Metal Fabrications.

B. Grating Clamps:

1. Use at flanged beam and bolted angle frame supports.

2. Removable from above grating walkway surface.

3. Provide hat bracket, recessed bolt, and bottom clamp of same material as grating.

C. Anchor Stud and Saddle Clip:

1. Use at embedded angle frame supports with stud anchor and nut recessed below top of grating surface.

2. Removable from above grating walkway surface.

3. Provide Type 316 stainless steel welded threaded stud anchor, nut, washer, and saddle clip.

2.07 FABRICATION

A. General:

1. In accordance with NAAMM MBG 531 or NAAMM MBG 532.

2. Conceal fastenings where practical.

3. Drill metalwork and countersink holes as required for attaching hardware or other materials.

4. Cutouts:

a. Fabricate in grating sections for penetrations indicated.

b. Arrange to permit grating removal without disturbing items penetrating grating.

c. Edge band openings in grating that interrupt four or more bearing bars with bars of same size and material as bearing bars.

5. Do not notch bearing bars at supports to maintain elevation.

6. Field measure areas to receive grating. Verify dimensions of new fabricated supports, and fabricate to dimension required for specified clearances.

Amendment No. 002

Metal Gratings 05 53 00 - 5

7. Section Length: Sufficient to prevent section from falling through clear opening when oriented in the span direction and one end is touching either the concrete or the vertical leg of grating support.

8. Minimum Bearing: 1 inch for grating depth up to 2-1/4 inches and 2 inches for grating depth greater than 2-1/4 inches.

9. Banding and Toe Plates: Same material as grating and welded to bearing bars in accordance with requirements of NAAMM MBG 531 and

NAAMM MBG 532.

B. Metal Bar Grating: A single grating section shall be not less than 1.5 feet or greater than 3 feet in width, or weigh more than 150 pounds.

C. Heavy Duty Metal Bar Grating: Minimum width of grating sections shall be 2 feet regardless of length and weight.

D. Supports:

1. Same material as grating, except that supports which are to be embedded in concrete shall be Type 316 stainless steel, unless part of an extruded aluminum system.

2. Coordinate dimensions and fabrication with grating to be supported.

PART 3 EXECUTION

3.01 INSTALLATION

A. Until grating sections are securely fastened in place, area shall be appropriately barricaded or flagged to alert people working in the area of potential fall hazard.

B. Install manufactured products in accordance with manufacturer’s recommendations.

C. Install supports such that grating sections have a solid bearing on both ends, and that grating sections will not rock or wobble under design loads.

D. Install grating supports plumb and level as applicable.

E. Install sections of welded frames with anchors to straight plane without offsets.

F. Field locate and install fasteners to fit grating layout.

G. Anchor grating securely to supports using minimum of four fastener clips and bolts per grating section.

H. Each grating or plank section shall be easily removable and replaceable.

I. Completed installation shall be rigid and neat in appearance.

J. Protect painted and galvanized surfaces during installation.

END OF SECTION

Amendment No. 002

Finish Hardware 08 71 00 - 16

1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 1 Wire Harness WH-192 ST 1 Wire Harness WH-192P ST 1 Card Reader Per Section 28 13 70 1 Gasketing 305 CR Head & Jambs PE 1 Door Sweep 315 CN PE 1 Threshold per detail AL PE 1 Rain Drip 345 C x 4” ODW AL PE

NOTE:

Operation: Presenting a valid credential to the card reader unlocks the door allowing entry.

Free egress from the inside at all times.

SET #19

3 Hinges FBB179 5 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Closer / Stop / Hold Open QDC120 SN 689 SH 1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Gasketing 379 CR Head & Jambs PE 1 Auto Door Bottom 412 PKL PE

SET #19A

3 Hinges FBB179 5 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Closer/Stop/Hold Open QDC120 SN 689 SH 1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 1 Gasketing 379 CR Head & Jambs PE 1 Auto Door Bottom 412 PKL PE

SET #20

1 Continuous Hinge 662HD CS UL x EPT prep AL ST 1 Exit Device 55-56-AD8510 630 SA 1 Closer / Stop / Hold Open QDC120 SN 689 SH 1 Drop Plate 8Q00471 x 8Q00473 689 SH 1 Wire Harness WH-192P ST 1 Wire Harness WH-192 ST 1 Power Transfer EPT-12C PR 1 Card Reader Per Section 28 13 70 1 Power Supply 3540 SA 1 Threshold (dr.103B) 273A 1/4-20 SSMS/LA AL PE 1 Threshold (except dr. 103B) 573x5AFG 1/4-20 SSMS/LA AL PE 1 Wall Bumper

(Door 131D only) 1270WV 630 TR

Amendment No. 002

Finish Hardware

08 71 00 - 17

NOTE: Seals and Gaskets are by door manufacturer.

Operation: Presenting a valid credential to the card reader retracts the latch on the exit device allowing entry. The exit device contains the switches for the request to exit function. Free egress from the inside at all times.

SET #21

1 Continuous Hinge 662HD CS UL x EPT prep AL ST 1 Exit Device 55-56-AD8504 630 SA 1 Rim Cylinder 12E-72 PATD 626 BE 1 Closer / Stop / Hold Open QDC120 SN 689 SH 1 Drop Plate 8Q00471 x 8Q00473 689 SH 1 Power Transfer EPT-12C PR 1 Wire Harness WH-192P ST 1 Wire Harness WH-192 ST 1 Card Reader Per Section 28 13 70 1 Power Supply 3540 SA 1 Threshold 2550 A 1/4-20 SSMS/LA AL PE

NOTE: Seals & Gaskets are by door manufacturer.

Operation: Presenting a valid credential to the card reader retracts the latch on the exit device allowing entry. The exit device contains the switches for the request to exit function. Free egress from the inside at all times.

SET #22

1 All Hardware is by Door Manufacturer except: BY 1 Mortise Cylinder 1E-74 PATD 626 BE 2 Wall Bumper 1270WV 630 TR

SET #23

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Closer / Stop / Hold Open QDC120 SN 689 SH

1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 3 Door Silencers 1229A GREY TR

08 71 00 - 18

SET #24

2 Hinges FBB179 5 X 4 1/2 US26D ST 1 Electric Hinge CECSFBB179-54 5 x 4 1/2 US26D ST 1 Electro-mech Lock 45HW-7DEU15H RQE PATD C 630 BE 1 Armor Plate KO050 36" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 1 Wire Harness WH-192 ST 1 Wire Harness WH-192P ST 1 Card Reader Per Section 28 13 70 3 Door Silencers 1229A GREY TR

NOTE:

Operation: Presenting a valid credential to the card reader unlocks the door allowing entry.

Free egress from the inside at all times.

SET #25

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Armor Plate KO050 36" x 2" LDW B4E CSK 630 TR 1 Closer / Stop / Hold Open QDC120 SN 689 SH 3 Door Silencers 1229A GREY TR

SET #26

2 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Electric Hinge CECSFBB179-54 4 1/2 x 4 1/2 US26D ST 1 Electro-mech Lock 45HW-7DEU15H RQE PATD C 630 BE 1 Closer / Stop QDC119 SN 689 SH 1 Armor Plate KO050 36" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 1 Wire Harness WH-192 ST 1 Wire Harness WH-192P ST 1 Card Reader Per Section 28 13 70 3 Door Silencers 1229A GREY TR

NOTE:

Operation: Presenting a valid credential to the card reader unlocks the door allowing entry.

Free egress from the inside at all times.

SET #27 (Not Used)

SET #28

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR

08 71 00 - 19

1 Wall Bumper 1270WV 630 TR 3 Door Silencers 1229A GREY TR

SET #29

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H TAC-O 630 BE 1 Closer / Stop / Hold Open QDC120 SN 689 SH 3 Door Silencers 1229A GREY TR

SET #30

3 Hinges FBB179 5 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Overhead Holder 4410 Series US32D AB 3 Door Silencers 1229A GREY TR

SET #31

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Closer / Stop / Hold Open QDC120 SN 689 SH 3 Door Silencers 1229A GREY TR

SET #32

6 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 2 Flush Bolt 3917-12 626 TR 1 Dustproof Strike 3911 630 TR 1 Passage Set 45H-0N15H 630 BE 1 Door Closer QDC111 SN 689 SH 2 Door Stop 1214CK 626 TR 2 Door Silencers 1229A GREY TR

SET #33

2 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Electric Hinge CEFBB179-54 4 1/2 x 4 1/2 US26D ST 1 Electro-mech Lock 45HW-7DEU15H RQE PATD C 630 BE 1 Door Closer QDC111 SN 689 SH 1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Door Stop 1214CK 626 TR 1 Wire Harness WH-192 ST 1 Wire Harness WH-192P ST 1 Card Reader Per Section 28 13 70 3 Door Silencers 1229A GREY TR

NOTE:

Operation: Presenting a valid credential to the card reader unlocks the door allowing entry.

Free egress from the inside at all times.

Amendment No. 002

Finish Hardware 08 71 00 - 20

SET #34

3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Lockset 45H-7D15H PATD 630 BE 1 Wall Bumper 1270WV 630 TR 1 Rain Drip 345 C x 4” ODW AL PE 1 Gasketing 379 CR Head & Jambs PE 1 Door Sweep 315 CN PE 1 Threshold 2550 A 1/4-20 SSMS/LA AL PE

SET #34A

2 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Passage Set 45H-0N15H 630 BE 1 Wall Bumper 1270WV 630 TR 3 Door Silencers 1229A GREY TR

SET #35

3 Hinges FBB191 4 1/2 X 4 1/2 NRP US32D ST 1 Lock 45H-7D15H PATD 630 BE 1 Door Closer QDC111 SN 689 SH 1 Kick Plate KO050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270WV 630 TR 1 Gasketing 305 CR Head & Jambs PE 1 Door Sweep 315 CN PE 1 Threshold per detail AL PE

Door Hardware Index

NUMBER HW NUMBER HW NUMBER HW NUMBER HW

101 02 119A 21 131G 03 208 05 102 01 119B 13 131H 03 209 05 103A 03A 120A 14 131I 20 210 05 103B 20 120B 03B 132A 18 211 05 103C 04 122 26 132B 16 212 05 104 05A 123 15 133A 24 213 05 105 06 124 16 133B 25 215 33 106 07 126 16 134A 08 215A 34 107 07 127 32 134B 08 216 05A 109 23 128A 20 135 16 217 05A 110 05A 128B 13 136 28 218 05A 111 10 131A 03 202 03A 219 29 112 11 131B 03 203 17 220 30 113 09 131C 03 204 19 221 31 114 12 131D 20 205 19A 223 33 115 22 131E 03 206 05 301 34A 116 22 131F 03 207 05 400 35

Amendment No. 002

Glazing 08 80 00 - 18

B. Fully Tempered Glass: Heat strengthened safety glass complying with ASTM C1048, Kind FT and ANSI Z97.1 and CPSC 16 CFR.

C. Framing Sections: Provide metal perimeter framing to support glass panels and doors as detailed on Drawings and approved Shop Drawings.

D. Door Assembly:

1. Provide complete entry door assemblies including door panels, frames, and hardware for locations indicated on Drawings.

2. Type: Center pivoted, fully tempered, all-glass doors.

3. Size, shape, and configuration: As indicated on Drawings.

2.17 SWITCH (SMART) GLAZING

A. Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, manufacturers specified:

1. Innovative Glass Corp.; E Glass / LC Privacy Glass, www.InnovativeGlassCorp.com

2. Or equal.

B. Laminated Materials:

1. Privacy Films: Approximately 0.015-inch thick film.

2. Interlayers: 0.035-inch thickness.

3. Primary Glazing Products Options (Can Be Customized to the

Application):

a. Annealed Clear Glass: Clear, transparent, flat, annealed, float glass, conforming to ASTM C1036, Type I, Class 1, Quality q3.

b. Low Emissivity (Low-E) Glass: Clear glass with neutral coating pyrolytically applied to produce durable surface resulting in improved thermal performance and reduced solar heat gain.

c. Heat strengthened glass: Provide heat strengthened, annealed glass components where indicated or required to adequately support imposed loads, to allow for large glass size, and resist anticipated thermal stresses in accordance with ASTM C1048, Kind HS.

d. Fully Tempered Glass:

1) Provide heat tempered, annealed glass components where required to adequately resist loading conditions, size of units, and anticipated thermal stresses in accordance with ASTM C1048, Kind FT.

2) Fully tempered glass shall meet requirements of ANSI Z97.1 and CPSC 16 CFR to qualify as safety glass.

http://www.innovativeglasscorp.com/

Drawings 52 00 00 - 2

TABLE A – LIST OF DRAWINGS

Sheet No. Drawing No. Title

2 222-100-60016 INDEX TO DRAWINGS (Revised 8-5-2016)

3 222-100-60017 CIVIL NOTES, LEGEND, & ABBREVIATIONS

4 222-100-60018 STRUCTURAL NOTES

5 222-100-60019

STRUCTURAL NOTES, LEGEND, &

ABBREVIATIONS(Revised 8-5-2016)

6 222-100-60020

MECHANICAL HVAC NOTES, LEGEND, &

ABBREVIATIONS

7 222-100-60021

MECHANICAL PLUMBING NOTES, LEGEND, &

ABBREVIATIONS

8 222-100-60022 ELECTRICAL LEGEND & GENERAL NOTES

9 222-100-60023

COMMUNICATIONS & FIRE ALARM LEGENDS &

GENERAL NOTES(Revised 8-5-2016)

10 222-100-60024 SITE OVERVIEW PLAN

11 222-100-60025 EXISTING SITE CONDITIONS(Revised 8-5-2016)

12 222-100-60026 SITE DEMOLITION PLAN

13 222-100-60027 SITE LAYOUT PLAN(Revised 8-5-2016)

14 222-100-60028 PCCP JOINTING PLAN

15 222-100-60029 GRADING & DRAINAGE PLAN

16 222-100-60030 ELEVATION LAYOUT & POINT TABLE

17 222-100-60031 UTILITY PLAN

18 222-100-60032 SIGNAGE & STRIPING PLAN

19 222-100-60033 LANDSCAPE PLAN

20 222-100-60034 LANDSCAPE DETAILS

21 222-100-60035

INDUSTRIAL WAY AND UNNAMED CANAL ROAD

PLAN & PROFILE SOUTH TO NORTH

22 222-100-60036

B STREET AND INDUSTRIAL WAY PLAN & PROFILE

WEST TO EAST

23 222-100-60037 RETAINING WALL PLAN & PROFILE WEST TO EAST

24 222-100-60038 WATER MAIN PLAN & PROFILE STA 0+00 TO 13+00

25 222-100-60039

WATER MAIN PLAN & PROFILE STA 13+00 TO

23+00(Revised 8-5-2016)

26 222-100-60040 SITE DETAILS 1

27 222-100-60041 SITE DETAILS 2

28 222-100-60042 SITE DETAILS 3

29 222-100-60043 SITE DETAILS 4(Revised 8-5-2016)

30 222-100-60044 DRAINAGE DETAILS 1

31 222-100-60045 DRAINAGE DETAILS 2

32 222-100-60046 DUMPSTER ENCLOSURE & PCCP JOINT DETAILS

33 222-100-60047 STRIPING DETAILS

34 222-100-60048 SIGNAGE DETAILS

35 222-100-60049 TYPICAL SECTIONS

36 222-100-60050 SITE SECTIONS

52 00 00 - 3

TABLE A – LIST OF DRAWINGS

Sheet No. Drawing No. Title

37 222-100-60051 PRECAST WATER INTERTIE BUILDING

38 222-100-60052 PROJECT DATA / GENERAL NOTES(Revised 8-5-2016) 39 222-100-60053 CODE INFO(Revised 8-5-2016) 40 222-100-60054 FIRST FLOOR PLAN(Revised 8-5-2016) 41 222-100-60055 FIRST FLOOR DIMENSIONS PLAN(Revised 8-5-2016) 42 222-100-60056 SECOND FLOOR PLAN(Revised 8-5-2016) 43 222-100-60057 SECOND FLOOR DIMENSIONS PLAN(Revised 8-5-2016) 44 222-100-60058 ROOF PLAN(Revised 8-5-2016) 45 222-100-60059 BUILDING ELEVATIONS(Revised 8-5-2016) 46 222-100-60060 BUILDING ELEVATIONS(Revised 8-5-2016) 47 222-100-60061 BUILDING ELEVATIONS(Revised 8-5-2016) 48 222-100-60062 BUILDING SECTIONS(Revised 8-5-2016) 49 222-100-60063 BUILDING SECTIONS(Revised 8-5-2016) 50 222-100-60064 BUILDING SECTIONS(Revised 8-5-2016) 51 222-100-60065 WALL SECTIONS(Revised 8-5-2016) 52 222-100-60066 WALL SECTIONS(Revised 8-5-2016) 53 222-100-60067 WALL SECTIONS(Revised 8-5-2016) 54 222-100-60068 EXTERIOR DETAILS(Revised 8-5-2016) 55 222-100-60069 EXTERIOR DETAILS(Revised 8-5-2016) 56 222-100-60070 EXTERIOR DETAILS(Revised 8-5-2016) 57 222-100-60071 EXTERIOR DETAILS(Revised 8-5-2016) 58 222-100-60072 EXTERIOR DETAILS(Revised 8-5-2016) 59 222-100-60073 EXTERIOR DETAILS(Revised 8-5-2016) 60 222-100-60074 STAIR PLANS AND SECTIONS(Revised 8-5-2016) 61 222-100-60075 STAIR DETAILS(Revised 8-5-2016) 62 222-100-60076 ENLARGED FLOOR PLANS(Revised 8-5-2016)

63 222-100-60077 ELEVATOR AND SLIDE POLE DETAILS(Revised 8-5- 2016)

64 DELETED

65 222-100-60079 FIRST FLOOR REFLECTED CEILING PLAN(Revised 8-5- 2016)

66 222-100-60080 SECOND FLOOR REFLECTED CEILING PLAN(Revised 8-5-2016)

67 222-100-60081 INTERIOR ELEVATIONS(Revised 8-5-2016) 68 222-100-60082 INTERIOR ELEVATIONS(Revised 8-5-2016) 69 222-100-60083 INTERIOR ELEVATIONS(Revised 8-5-2016) 70 222-100-60084 INTERIOR ELEVATIONS(Revised 8-5-2016) 71 222-100-60085 INTERIOR ELEVATIONS(Revised 8-5-2016) 72 222-100-60086 INTERIOR DETAILS/CEILING(Revised 8-5-2016) 73 222-100-60087 INTERIOR DETAILS/FLOOR & WALL(Revised 8-5-2016) 74 222-100-60088 INTERIOR DETAILS/MILLWORK(Revised 8-5-2016) 75 222-100-60089 INTERIOR DETAILS(Revised 8-5-2016)

52 00 00 - 4

TABLE A – LIST OF DRAWINGS

Sheet No. Drawing No. Title

76 222-100-60090 FIRST FLOOR FINISH PLAN(Revised 8-5-2016) 77 222-100-60091 SECOND FLOOR FINISH PLAN(Revised 8-5-2016) 78 222-100-60092 FINISH SCHEDULE(Revised 8-5-2016) 79 222-100-60093 DOOR SCHEDULE(Revised 8-5-2016) 80 222-100-60094 GLAZING SYSTEM TYPES(Revised 8-5-2016) 81 222-100-60095 GLAZING SYSTEM TYPES(Revised 8-5-2016) 82 222-100-60096 DOOR AND WINDOW DETAILS(Revised 8-5-2016) 83 222-100-60097 DOOR AND WINDOW DETAILS(Revised 8-5-2016) 84 222-100-60098 DOOR AND WINDOW DETAILS(Revised 8-5-2016) 85 222-100-60099 DOOR AND WINDOW DETAILS(Revised 8-5-2016) 86 222-100-60100 WALL TYPES(Revised 8-5-2016) 87 222-100-60101 FIRST FLOOR/FOUNDATION PLAN(Revised 8-5-2016) 88 222-100-60102 SECOND FLOOR FRAMING PLAN(Revised 8-5-2016) 89 222-100-60103 LOWER ROOF PLAN(Revised 8-5-2016) 90 222-100-60104 UPPER ROOF FRAMING PLAN(Revised 8-5-2016) 91 222-100-60105 CMU WALL ELEVATIONS(Revised 8-5-2016) 92 222-100-60106 CMU WALL ELEVATIONS(Revised 8-5-2016)

93 222-100-60107 CMU WALL ELEVATIONS

94 222-100-60109 SECTIONS

95 222-100-60110 SECTIONS(Revised 8-5-2016)

96 222-100-60111 SECTIONS

97 222-100-60112 ENLARGED PLANS AND DETAILS

98 222-100-60113 TRUSS ELEVATIONS

99 222-100-60114 TRUSS DETAILS

100 222-100-60115 STEEL BRACED FRAME DETAILS(Revised 8-5-2016) 101 222-100-60116 CONCRETE DETAILS(Revised 8-5-2016) 102 222-100-60117 CONCRETE DETAILS(Revised 8-5-2016) 103 222-100-60118 CONCRETE DETAILS(Revised 8-5-2016)

104 222-100-60119 DETAILS

105 222-100-60120 DETAILS

106 222-100-60121 DETAILS(Revised 8-5-2016)

107 222-100-60123 COLUMN SCHEDULE

108 222-100-60124 SCHEDULES

109 222-100-60125 TYPICAL CONCRETE DETAILS

110 222-100-60126 TYPICAL CONCRETE DETAILS(Revised 8-5-2016)

111 222-100-60127 TYPICAL CONCRETE DETAILS

112 222-100-60129 TYPICAL MASONRY DETAILS

113 222-100-60130 TYPICAL MASONRY DETAILS

114 222-100-60131 TYPICAL MASONRY DETAILS

115 222-100-60132 TYPICAL STEEL DETAILS

116 222-100-60133 TYPICAL STEEL DETAILS(Revised 8-5-2016)

117 222-100-60134 TYPICAL STEEL DETAILS

52 00 00 - 5

TABLE A – LIST OF DRAWINGS

Sheet No. Drawing No. Title

118 222-100-60135 TYPICAL STEEL DETAILS(Revised 8-5-2016)

119 222-100-60136 TYPICAL STEEL DETAILS

120 222-100-60137 STAIR FRAMING PLANS AND DETAILS(Revised 8-5- 2016)

121 222-100-60138 TYPICAL STEEL DETAILS

122 222-100-60140 HVAC FIRST FLOOR PLAN

123 222-100-60141 HVAC SECOND FLOOR PLAN

124 222-100-60142 HVAC MECHANICAL ROOM ENLARGED PLAN

125 222-100-60143 HVAC MECHANICAL MEZZANINE ENLARGED PLAN

126 222-100-60144 HVAC REFRIGERANT PIPING FIRST FLOOR PLAN

127 222-100-60145 HVAC REFRIGERANT PIPING SECOND FLOOR PLAN

128 222-100-60146 HVAC SECTIONS

129 222-100-60147 HVAC APPARATUS BAY RADIANT FLOOR PLAN

130 222-100-60148 HVAC AIRFLOW DIAGRAMS

131 222-100-60149 HVAC AIRFLOW AND CONTROL DIAGRAMS

132 222-100-60150 HVAC CONTROL DIAGRAMS

133 222-100-60151 HVAC DETAILS 1

134 222-100-60152 HVAC DETAILS 2

135 222-100-60153 HVAC DETAILS 3

136 222-100-60154

HVAC DETAILS AND REFRIGERANT PIPING

SCHEMATIC

137 222-100-60155 HVAC SCHEDULES 1

138 222-100-60156 HVAC SCHEDULES 2

139 222-100-60157 HVAC SCHEDULES 3

140 222-100-60158

PLUMBING SERVICE PIPING PLAN FIRST

FLOOR(Revised 8-5-2016)

141 222-100-60159

PLUMBING SERVICE PIPING PLAN SECOND

FLOOR(Revised 8-5-2016)

142 222-100-60160 PLUMBING WASTE & VENT PLAN FIRST FLOOR

143 222-100-60161

PLUMBING WASTE & VENT PLAN SECOND

FLOOR(Revised 8-5-2016)

144 222-100-60162 PLUMBING WASTE & VENT PLAN ROOF(Revised 8-5- 2016)

145 222-100-60163 PLUMBING FIRST FLOOR CONDENSATE PLAN

146 222-100-60164 PLUMBING SECOND FLOOR CONDENSATE PLAN

147 222-100-60225 PLUMBING ENLARGED PLANS(Revised 8-5-2016) 148 222-100-60226 PLUMBING ENLARGED PLANS(Revised 8-5-2016)

149 222-100-60227 PLUMBING DETAILS 1

150 222-100-60228 PLUMBING DETAILS 2(Revised 8-5-2016)

151 222-100-60229

PLUMBING SERVICE WATER SCHEMATIC FIRST

FLOOR

52 00 00 - 6

TABLE A – LIST OF DRAWINGS

Sheet No. Drawing No. Title

152 222-100-60230

PLUMBING SERVICE WATER SCHEMATIC SECOND

FLOOR

153 222-100-60231 PLUMBING SCHEDULES

154 222-100-60232 SITE PLAN

155 222-100-60233 ENLARGED SITE PLAN

156 222-100-60234 ONE-LINE DIAGRAM

157 222-100-60235 POWER PLAN FIRST FLOOR(Revised 8-5-2016) 158 222-100-60236 POWER PLAN SECOND FLOOR(Revised 8-5-2016)

159 222-100-60237

ENLARGED PLANS 1 AND CONTROL DIAGRAMS

(Revised 8-5-2016)

160 222-100-60238 ENLARGED PLANS 2(Revised 8-5-2016) 161 222-100-60239 LIGHTING PLAN FIRST FLOOR(Revised 8-5-2016) 162 222-100-60240 LIGHTING PLAN SECOND FLOOR(Revised 8-5-2016) 163 222-100-60241 LIGHTING SCHEDULES(Revised 8-5-2016) 164 222-100-60242 PANEL SCHEDULES(Revised 8-5-2016) 165 222-100-60243 DETAILS 1(Revised 8-5-2016)

166 222-100-60244 DETAILS 2

167 222-100-60245 DETAILS 3

168 222-100-60246 DETAILS 4(Revised 8-5-2016) 169 222-100-60247 DETAILS 5(Revised 8-5-2016) 170 222-100-60248 DETAILS 6(Revised 8-5-2016)

171 222-100-60249 FIRST FLOOR PLAN

172 222-100-60250 SECOND FLOOR PLAN

173 222-100-60251 DETAILS 1

174 222-100-60252 DETAILS 2

175 222-100-60253 SITE PLAN

176 222-100-60254 FLOOR PLANS KEYED NOTES

177 222-100-60255 FIRST FLOOR PLAN

178 222-100-60256 SECOND FLOOR PLAN

179 222-100-60257 DETAILS 1

180 222-100-60258 DETAILS 2

181 222-100-60259 DETAILS 3

182 222-100-60260 DETAILS 4

183 222-100-60261 DETAILS 5

184 222-100-60262 DETAILS 6

185 222-100-60263 DETAILS 7

186 222-100-60264 FIRST FLOOR PLAN

187 222-100-60265 SECOND FLOOR PLAN

188 222-100-60266 DETAILS 1

189 222-100-60267 DETAILS 2

Amendment No. 002

Drawings 52 00 00 - 7

PART 2 PRODUCTS (NOT USED)

PART 3 EXECUTION (NOT USED)

Grand Coulee Fire Station Columbia

Basin Project, Washington Amendment No. 002

SECTION F DELIVERIES OR PERFORMANCE

F.1. 52.211-10 COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK (APR

1984)

The Contractor shall be required to (a) commence work under this contract within 10 calendar days after the date the Contractor receives the notice to proceed, (b) prosecute the work diligently, and

(c) complete the entire work ready for use not later than April 30, 2018, after receipt of the notice to proceed. The time stated for completion shall include final cleanup of the premises.

F.2. 52.211-12 LIQUIDATED DAMAGES--CONSTRUCTION (SEPT 2000)

(a) If the Contractor fails to complete the work within the time specified in the contract, or any extension, the Contractor shall pay liquidated damages to the Government in the amount of $1,160.00 for each calendar day of delay until the work is completed or accepted.

(b) If the Government terminates the Contractor's right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

F.3. 52.242-14 SUSPENSION OF WORK (APR 1984)

(a) The Contracting Officer may order the Contractor, in writing, to suspend, delay, or interrupt all or any part of the work of this contract for the period of time that the Contracting Officer determines appropriate for the convenience of the Government.

(b) If the performance of all or any part of the work is, for an unreasonable period of time, suspended, delayed, or interrupted (1) by an act of the Contracting Officer in the administration of this contract, or (2) by the Contracting Officer's failure to act within the time specified in this contract (or within a reasonable time if not specified), an adjustment shall be made for any increase in the cost of performance of this contract (excluding profit) necessarily caused by the unreasonable suspension, delay, or interruption, and the contract modified in writing accordingly. However, no adjustment shall be made under this clause for any suspension, delay, or interruption to the extent that performance would have been so suspended, delayed, or interrupted by any other cause, including the fault or negligence of the Contractor, or for which an equitable adjustment is provided for or excluded under any other term or condition of this contract.

(c) A claim under this clause shall not be allowed (1) for any costs incurred more than 20 days before the Contractor shall have notified the Contracting Officer in writing of the act or failure to act involved (but this requirement shall not apply as to a claim resulting from a suspension order), and (2) unless the claim, in an amount stated, is asserted in writing as soon as practicable after the termination of the suspension, delay, or interruption, but not later than the date of final payment under the contract.

F-1

1 part 1 GENERAL
1.01 PAYMENT
A. Include in lump sum price offered for the Grand Coulee Power Office Fire Station.
1.02 SUMMARY
A. This section includes the following:
1. Door hardware.
2. Hardware for aluminum doors.
B. Related Sections:
1. Section 01 81 13, Sustainable Design Requirements, for applicable Guiding Principle Compliance Requirements as assessed through GBCI-NC 2009 Compliance Path.
2. Section 08 11 13, Hollow Metal Doors and Frames.
3. Section 08 14 16, Flush Wood Doors.
4. Section 08 41 13, Aluminum Entrance and Storefronts.
5. Section 08 44 13, Glazed Aluminum Curtain Walls.
1.03 REFERENCES
A. NFPA80, Fire Doors and Windows.
B. NFPA101, Life Safety Code.
C. NFPA105, Smoke and Draft Control Door Assemblies.
D. Architectural Barriers Act ABA 2015 Standards for making Buildings usable by physically handicapped people.
1.04 GUIDING PRINCIPLE COMPLIANCE THROUGH GBCI-NC 2009 COMPLIANCE PATH
A. This Project is targeting Guiding Principle Compliance through GBCI-NC 2009 Compliance Path. It is the Contractor’s responsibility to familiarize themselves with this program, to determine which points in the system that are relevant for this proje...
1.05 SUBMITTALS
A. RSN 08 71 00-1, Hardware Schedule: At the earliest possible date, Submit 6 copies of schedule, organized vertically. Format into Hardware Sets with index of doors and headings, indication complete designations of every item required for each door o...
1. Include the following:
a. Type, style, function, size, quantity and finish of hardware items.
b. Name, part number and manufacture of each item.
c. Fastenings and other pertinent information.
d. Explanation of abbreviations, symbols and codes contained in schedule.
e. Door and frame sizes, materials and degrees of swing.

2. Review of hardware schedule does not relieve the Contractor of responsibility to fulfill project requirements in accordance with Contract Documents.

B. RSN 08 71 00-2, Product Data: Submit 4 copies for each product indicated.
C. RSN 08 71 00-3, Installation Instructions: Submit 1 copy of basic installation instructions for locks, latches closures and concealed sweeps.
D. RSN 08 71 00-4, Templates: Obtain and distribute templates for doors, frames, and other works specified, to be prepared for installing door hardware.
E. RSN 08 71 00-5, Wiring/Riser diagrams: Provide wiring diagrams and point to point electrical drawings for electric hardware.
F. RSN 08 71 00-6, Maintenance Data: For each type of door hardware to include in maintenance manuals specified in Division 01, General Requirements Specifications.
G. RSN 08 71 00-7, Keying Schedule: Prepared by or under the supervision of supplier, after receipt of the approved finish hardware schedule, detailing Owner’s final keying instructions for locks.
H. RSN 08 71 00-8, Samples: Upon request submit material samples.
I. RSN 08 71 00-9, Product Qualification:
1. To assure a uniform high quality of materials for the project, it is intended that only specified items be furnished. Comparable products may be accepted upon prior approval of Architect.
2. Hardware to be new, free of defects, blemishes and excessive play. Obtain each kind of hardware (latch and locksets, exit devices, hinges and closers) from one manufacturer except where specified.
3. Fire-Rated opening in compliance with NFPA 80. Hardware UL10C/UBC-7-2 (positive pressure) compliant for given type/size opening and degree of label. Provide proper latching hardware, nonflaming door closers, approved bearing hinges and smoke seal. ...
J. RSN 08 71 00-10, Supplier Qualifications:
1. Hardware supplier will be a direct factory contract supplier who employs a certified architectural hardware consultant (AHC) available at all reasonable time during the course of the work for project hardware consultation to Owner, Architect and Co...
2. Supplier shall have furnished hardware in the same area as the project for a period of not less than 2 years.
3. Supplier will be responsible for detailing, scheduling and ordering of finish hardware.
4. Supplier shall be located within 200 miles of the project.
5. Supplier shall be a distributor for the specified products, not a broker.
6. Supplier shall maintain a warehouse and stock of specified hardware and replacement parts.
7. Conduct preinstallation conference at jobsite. Initiate and conduct with supplier, installer and related trades. Coordinate materials and techniques and sequence complex hardware items and systems installation.
8. Key conference shall be initiated and conducted with Owner to determine system, keyway(s) and structure.
K. RSN 08 71 00-11, Installer Qualifications:
1. Installer to have not less than 3-year experience specializing in installation of work in this section. Company must maintain qualified personnel trained and experienced in installing hardware.
2. Hardware installation shall not be self-performed by the General Contractor unless the installer meets the qualifications notes above.
L. RSN 08 71 00-12, Delivery, Storage and Handling:
1. Deliver, store, handle and protect products to project site under provisions of Division 01, General Requirements and as specified herein.
2. Tag each item or package separately, with identification related to the final Door Hardware Schedule, and include basic installation instructions with each item or package.
3. Deliver keys to Owner by registered mail.
1.06 WARRANTY
A. The finish hardware shall have a limited warranty against defects in workmanship and operation for a period of 1 year from date of substantial completions and the following items are as shown:
1. Closers: Lifetime mechanical, 2 years electrical.
2. Exit Devices: 5 years mechanical, 1 year electrical.
3. Hinges: Life of the building.
4. Locksets: 7 years (Cylindrical) Lifetime (Mortise).
2 part 2 PRODUCTS
2.01 MATERIAL AND FABRICATION
A. Provide all door hardware for complete work, in accordance with the drawings and as specified herein.
B. Provide items and quantities not specifically mentioned to ensure a proper and complete operational installation.
2.02 MANUFACTURERS
A. Any item shown in the hardware schedule, but not listed below shall be supplied as shown unless otherwise approved by the COR.
2.03 HANGING
A. Conventional Hinges: Hinge open width minimum, but of sufficient throw to permit maximum door swing. Steel or stainless steel pins.
1. Three hinges per leaf to 7-foot 6-inch height. Add one for each additional 30 inches in height or any fraction thereof (five hinges at 9 feet 4 inches doors).
2. Provide 4-1/2 by 4-1/2 for 1-3/4-inch thick doors up to 36 inches. Provide 5 by 4-1/2 on doors over 36 inches.
3. Out swinging exterior doors to have nonremovable (NRP) pins.
4. Pin tips, flat button, finish to match leaves.
B. Locksets, Latchsets, Deadbolts:
1. Cylindrical Type Locks and Latchsets:
a. Tested and approved by BHMA for ANSI A156.2, Series 4000, Operational Grade 1, Extra-Heavy Duty, and be UL 10C listed.
b. Provide 9001-Quality Management and 14001-Environmental Management.
c. Fit modified ANSI A115.2 door preparation.
d. Locksets and cores to be of the same manufacturer to maintain complete lockset warranty.
e. Locksets to have anti-rotational studs that are thru-bolted.
f. Keyed lever shall not have exposed “keeper” hole.
g. Each lever to have independent spring mechanism controlling it.
h. 2-3/4 inch (70 mm) backset.
i. 9/16-inch (14 mm) throw latchbolt.
j. Provide sufficient curved strike lip to protect door trim.
k. Outside lever sleeve to be seamless, of one-piece construction made of a hardened steel alloy.
l. Keyed lever to be removable only after core is removed, by authorized control key.
m. Provide locksets with 7-pin removable and interchangeable core cylinders.
n. Hub, side plate, shrouded rose, locking pin to be a one-piece casting with a shrouded locking lug.
o. Locksets outside locked lever must withstand minimum 1,400-inch pounds of torque. In excess of that, a replaceable part will shear. Key from outside and inside lever will still operate lockset.
p. Core face must be the same finish as the lockset.
q. Functions and design as indicated in the hardware groups.
2.04 KEYS, KEYING, AND KEY CONTROL
A. Keying shall be established at a keying conference attended by the COR and Hardware supplier. Provide permanent key schedules in a format acceptable to the Owner. Cylinders to be Cormax Patented SFIC interchangeable cores at all lockable items.
B. Provide permanent key schedule in a format acceptable to the COR. All permanent keys shall be hand delivered or sent via registered mail directly to the COR.
C. Provide Construction cylinders for exterior doors.
1. 3 keys per cylinders.
2. 3 control keys.
3. 12 Master keys.
4. 6 Construction keys.
5. 1 Key Cabinet RWC25S.
2.05 EXIT DEVICES/PANIC HARDWARE
A. General Features:
1. Independent lab-tested 1,000,000 cycles.
2. Push-through touch pad design. No exposed touch bar fasteners, no exposed cavities when operated. 3/4-inch throw deadlocking latcbolts.
3. No exposed screws to show through glass doors.
4. Nonhanded basic device design with center case interchangeable with all functions, no extra parts required to effect change of function.
5. Device installed on doors with vision lites shall not require glass bead shims if the exposed glass vision kit is 1/4 inch or less from the face of the door.
B. Specific Features:
1. Lever Trim: Breakaway type, forged brass or bronze escutcheon minimum 0.130-inch thickness, match lockset lever design.
2. Fire-Labeled Devices: UL label indicating Fire Exit Hardware.
2.06 CLOSERS
A. General Features:
1. Full rack-and-pinion type cylinder with removable non-ferrous cover and Aluminum R14 Silicon body. Cold forged pinion shaft, Cold forged piston with steel spring.
2. Certified to the requirements of the ANSI/BHMA Standard A156.4-2000 Grade 1.
3. Certified to meet UL10C and UBC 7.2 (1997).
4. Thru-bolts at wood doors unless doors are provided with closer blocking. Nonsized, nonhanded and adjustable. Place closers inside building, stairs and rooms.
5. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware.
6. Opening pressure: Exterior doors 8.5 pound, interior doors 5-pound, labeled fire doors 15-pound.
7. Separate adjusting valves for closing speed, latching speed and backcheck, fourth valve for delayed action where scheduled.
8. Exterior door closers: tested to 100 hours of ASTM B117 salt spray test, furnish data on request.
9. Exterior doors do not require seasonal adjustments in temperatures from 120 degrees F to 0 degrees F, furnish data on request.
10. Nonflaming fluid will not fuel door or floor covering fires.
2.07 OTHER HARDWARE
A. Door Stops: Provide stops to protect walls, casework or other hardware.
1. Except as otherwise indicated, provide stops (wall, floor or overhead) at each leaf of every swinging door leaf.
2. Where wall or floor stops are not appropriate, provide overhead holders.
B. Gaskets and Sweeps:
1. Provide continuous weather-strip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated or scheduled.
2. Provide noncorrosive fasteners as recommended by the manufacturer for application indicated.
C. Thresholds: Except as otherwise indicated, provide standard metal threshold unit of type, size and profile as detailed or scheduled.
D. Silencers: Interior hollow metal frames, four for single doors, six for pairs of doors.
2.08 HARDWARE FINISH
A. Provide the following finishes unless noted differently in hardware groups.
1. Wood or Hollow Metal Doors:
a. Locks:
1) Latches, Push, Pulls: 630.
b. Hinges: Exterior 630, Interior 652.
c. Closers: Painted Aluminum 689.
d. Exit Devices: 630.
e. Other Hardware: 626.
f. Thresholds: Alum.
g. Weatherstrip/Sweeps: Alum.
3 part 3 EXECUTION
3.01 ACCEPTABLE INSTALLERS
A. Factory trained, certified, and carries a factory-issued card certifying that person as a Certified Installer. Alternative: can demonstrate suitably equivalent competence and experience.
3.02 PREPARATION
A. Ensure that walls and frames are square and plumb before hardware installation.
B. Locate hardware per SDI-100 and applicable building, fire, life-safety, accessibility, and security codes. Notify Architect of any code conflicts before ordering materials.
3.03 INSTALLATION
A. Install hardware per manufacturer’s instructions and recommendations. Do not install surface mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substr...
B. Locate floor stops not more than 4 inches from the wall.
C. Place door stops and holders to allow maximum swing. Doors not to contact anything but stop.
D. Use cast-in-place anchor bolts or steel expansion shield for all items supported by, or on, new concrete.
E. Drill pilot holes for fasteners in wood doors and/or frames.
F. Make mortises accurately to exactly receive hardware. Depth of Mortises such that hardware is flush with finish surfaces.
G. Cut and fit thresholds to profiles of door jambs with mitered corners and precision joints. Set exterior thresholds in bed of butyl rubber sealant and fill all voids to exclude moisture. Do not block any weep holes and remove excess sealant. Align ...
H. Hardware Placement: Locate hardware on doors as follows:
1. Comply with Architectural Barriers Act ABA 2015 Standards where more stringent requirements are indicated.
2. Dimensions are from the finished floor to centerline unless shown otherwise.
a. Butts: As per approved metal jambs.
b. Lock/Latch: 40 inches centerline of strike.
c. Exit Device Cross Bar: 40 inches centerline of bar, except as required to clear vision lites.
d. Deadlock Cylinder: Architectural Barriers Act ABA 2015 Standards compliant.
e. All other items are manufacturer’s instructions or as directed.

I. After erection and glazing, check and adjust all operation hardware.

3.04 ADJUSTING
A. Adjust and check for proper operation and function. Replace units which cannot be adjusted to operate freely and smoothly.
B. Hardware damaged by improper installation or adjustment methods to be repaired or replaced to Owner’s satisfaction.
C. Make further adjustments required during guarantee period.
3.05 FOLLOWUP INSPECTION
A. Installer to provide letter of agreement to Owner that approximately 6 months after Substantial Completion, installer will visit project with representative of the manufacturers of the locking devices and door closers to accomplish the following:
1. Readjust locks and closers.
2. Evaluate maintenance procedures and recommend changes or additions, and instruct Owner’s personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems and likely future problems.
3.06 DEMONSTRATION
A. Demonstrate electrical, electronic and pneumatic hardware systems, including adjustment and maintenance procedures.
3.07 PROTECTION/CLEANING
A. Cover installed hardware, protect from paint, cleaning agents, weathering, carts/barrows, etc. Remove covering materials and clean hardware just prior to substantial completion.
B. Clean adjacent wall, frame and door surfaces soiled from installation/reinstallation process.

3.08 DOOR HARDWARE SCHEDULE

SET #01
SET #02
SET #03
SET #03A
SET #03B
SET #04
SET #05
SET #05A
SET #06
SET #07
SET #08
SET #09
SET #10
SET #11
SET #12
SET #13
SET #14
SET #15
SET #16
SET #17
SET #18
SET #19
SET #21
SET #22
SET #23
SET #24
SET #25
SET #26
SET #27 (Not Used)
SET #28
SET #29
SET #30
SET #31
SET #32
SET #33
SET #34
SET #34A
SET #35
END OF SECTION
HW
NUMBER
HW
NUMBER
HW
NUMBER
HW
NUMBER
05
208
03
131G
21
119A
02
101
05
209
03
131H
13
119B
01
102
05
210
20
131I
14
120A
03A
103A
05
211
18
132A
03B
120B
20
103B
05
212
16
132B
26
122
04
103C
05
213
24
133A
15
123
05A
104
33
215
25
133B
16
124
06
105
34
215A
08
134A
16
126
07
106
05A
216
08
134B
32
127
07
107
05A
217
16
135
20
128A
23
109
05A
218
28
136
13
128B
05A
110
29
219
03A
202
03
131A
10
111
30
220
17
203
03
131B
11
112
31
221
19
204
03
131C
09
113
33
223
19A
205
20
131D
12
114
34A
301
05
206
03
131E
22
115
35
400
05
207
03
131F
22
116
08_80_00I_Glazing amd 002.pdf
1 PART 1 GENERAL
1.01 PAYMENT
A. Include in lump sum price offered for the Grand Coulee Power Office Fire Station.
1.02 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, and Division 01 Specification Sections, apply to this Section.
1.03 SUMMARY
A. This Section includes glazing for the following products and applications, including those specified in other Sections where glazing requirements are specified by reference to this Section:
1. Aluminum windows.
2. Wood and hollow metal doors.
3. Hollow metal framed sidelites borrowed lites and transoms.
4. Aluminum storefront systems and entrances.
5. Quick response four-fold doors.
6. Aluminum curtain walls.
7. Glazed interior wall and door assemblies.
B. Related Requirements:
1. Section 01 81 13, Sustainable Design Requirements, for applicable Guiding Principle Compliance Requirements as assessed through GBCI-NC 2009 Compliance Path.
2. Section 08 11 13, Hollow Metal Doors and Frames.
3. Section 08 14 16, Flush Wood Doors.
4. Section 08 41 13, Aluminum Entrance and Storefronts.
5. Section 08 44 13, Glazed Aluminum Curtain Walls.
6. Section 08 51 13, Aluminum Windows.
7. Section 08 53 13, Quick Response Four-Fold Doors.
8. Section 08 83 00, Mirrors.
9. Division 26, Electrical.
1.04 GUIDING PRINCIPLE COMPLIANCE THROUGH GBCI-NC 2009 COMPLIANCE PATH
A. This Project is targeting Guiding Principle Compliance through GBCI-NC 2009 Compliance Path. It is the Contractor’s responsibility to familiarize themselves with this program, to determine which points in the system that are relevant for this Proje...
1.05 DEFINITIONS
A. Manufacturers of Glass Products: Firms that produce primary glass, fabricated glass, or both, as defined in referenced glazing publications.
B. Glass Thicknesses: Indicated by thickness designations in millimeters according to ASTM C1036.
C. Interspace: Space between lites of an insulating-glass unit that contains dehydrated air or a specified gas.
D. Deterioration of Coated Glass: Defects developed from normal use that are attributed to the manufacturing process and not to causes other than glass breakage and practices for maintaining and cleaning coated glass contrary to manufacturer's written...
E. Deterioration of Insulating Glass: Failure of hermetic seal under normal use that is attributed to the manufacturing process and not to causes other than glass breakage and practices for maintaining and cleaning insulating glass contrary to manufac...
F. Deterioration of Laminated Glass: Defects developed from normal use that are attributed to the manufacturing process and not to causes other than glass breakage and practices for maintaining and cleaning laminated glass contrary to manufacturer's w...
1.06 SUBMITTALS
A. RSN 08 80 00-1, Product Data: For each glass product and glazing material indicated.
B. RSN 08 80 00-2, Sustainable Design Submittals:
1. Product Data: For sealants, indicating VOC content.
2. Laboratory Test Reports: For sealants, indicating compliance with requirements for low-emitting materials.
C. RSN 08 80 00-3, Samples: For the following products, in the form of 12-inch (300-mm) square Samples for glass and of 12-inch (300-mm) long Samples for sealants. Install sealant Samples between two strips of material representative in color of the a...
1. Float glass.
2. Insulating glass for each designation indicated.
3. Fire-resistive glazing products.
4. Tempered glass.
5. Insulating glass.
6. Color of Spandrel glass.
7. Electrochromic glass.
8. Structural glass.
9. Ceramic coated glass.
10. Etched glass.
11. For each color (except black) of exposed glazing sealant indicated.
12. Two end state.
D. RSN 08 80 00-4, Glazing Schedule: Use same designations indicated on Drawings for glazed openings in preparing a schedule listing glass types and thicknesses for each size opening and location.
E. RSN 08 80 00-5, Product Certificates: Signed by manufacturers of glass and glazing products certifying that products furnished comply with requirements. For solar-control low-e-coated glass, provide documentation demonstrating that manufacturer of ...
F. RSN 08 80 00-6, Qualification Data: For an experienced installer who has completed glazing similar in material, design, and extent to that indicated for this Project; whose work has resulted in glass installations with a record of successful in-ser...
G. RSN 08 80 00-7, Preconstruction Adhesion and Compatibility Test Report: From glazing sealant manufacturer indicating glazing sealants were tested for adhesion to glass and glazing channel substrates and for compatibility with glass and other glazin...
H. RSN 08 80 00-8, Product Test Reports: For each of the following types of glazing products:
1. Float glass.
2. Tempered glass.
3. Insulating glass.
4. Spandrel glass.
5. Electrochromic glass.
6. Structural glass.
7. Ceramic coated glass.
8. Etched glass.
9. Glazing sealants.
10. Glazing gaskets.
I. RSN 08 80 00-9, Maintenance Data: For glazing to include in maintenance manuals.
J. RSN 08 80 00-10, Warranties: Special warranties specified in this Section.
K. RSN 08 80 00-11, Source Limitations:
1. Insulated Glass: Where a glass manufacturer is specified, obtain insulated glass in fabricated units from a manufacturer whose specific location and equipment is certified by the coating manufacturer.
2. Glazing Accessories: Obtain glazing accessories through one source from a single manufacturer for each product and installation method indicated.
L. RSN 08 80 00-12, Glass Product Testing: Obtain glass test results for product test reports in Submittals Article from a qualified testing agency based on testing glass products.
1. Glass Testing Agency Qualifications: An independent testing agency with the experience and capability to conduct the testing indicated, as documented according to ASTM E548.
M. RSN 08 80 00-13, Elastomeric Glazing Sealant Product Testing: Obtain sealant test results for product test reports in "Submittals" Article from a qualified testing agency based on testing current sealant formulations within a 36-month period.
1. Sealant Testing Agency Qualifications: An independent testing agency qualified according to ASTM C1021 to conduct the testing indicated, as documented according to ASTM E548.
2. Test elastomeric glazing sealants for compliance with requirements specified by reference to ASTM C920, and where applicable, to other standard test methods.