00_00_02_-_Drawings_(1).pdf
PDF 3 MB Posted
- Attached to
- Design Build Water Treatment Plant Federal contract opportunity
- Solicitation number
- R16PS00462
About this file
00 00 02 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 52_00_00_-_Drawings.docx | DOCX document | |
| 01_20_05_-_Cost_Estimating_Requirements.docx | DOCX document | |
| 00_00_01_-_Specifications.pdf | ||
| 01_86_46_-_Water_Treatment_Performance_Requirements.docx | DOCX document | |
| SF-30.pdf | ||
| R16PS00462_Solicitation_Amendment_5_(2).docx | DOCX document | |
| R16PS00462_Questions_and_Answers_Amendment_5.docx | DOCX document | |
| SF-30.pdf | ||
| R16PS00462_Solicitation_Amendment_4.docx | DOCX document | |
| Email_-_Re__Phase_2_R16PS00462.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R- 9- W
R- -WSe c 13Se c
Se c
Se c
LIMITS OF CULTURALLY
SENSITIVE AREA
LA167377
(SEE NOTE)
LIMITS OF CULTURALLY
SENSITIVE AREA
LA167378
(SEE NOTE)
1" = 100'
1" = 10'
JGG/JEG
Ph on e (5
) 2
-0
T ol l-F re e (8
) 2
-0
F ax
(5
) 2
-3 w w w .so ud er m ill er .c om
A lb uq ue rq ue
, F ar m in gt on
, L as
C ru ce s, R os w el l, Sa nt a
Fe , N
M
El P as o, T X
C or te z
- G ra nd Ju nc tio n
- M on tro se , C
O
Sa ff or d, A Z
- M on tic el lo , U
T
Se rv in g th e
So ut hw es t & R oc ky
M ou nt ai ns
SO
U
D
ER
, M
IL
LE
R
A
SS
O
C
IA
TE
S
Sheet:
Horiz:Scale:
Project No:
Vert:
Date:
C h k d
B y
D e s c r i p t i o n
D a t e
R e v i s i o n
THIS DRAWING IS INCOMPLETE
AND NOT TO BE USED FOR
CONSTRUCTION UNLESS IT IS
STAMPED, SIGNED AND DATED
C A
N D
EL
A
R
IA
R O
A D
N E, S U
IT
E
D A
LB
U
Q U
ER
Q
U E, N M
P:\6- Cutter Ph 3 (6418285)\Acad\RECORD DWGS\Construction Dwgs\Recd_for_pdf\Cutter Ph 3 PnP - (1)-RECD.dwg , 9/11/2014 12:30:55 PM mvh© Copyright 2012 Souder, Miller & Associates - All Rights Reserved
6418285
C L
I E
N T
T h e
N a v a j t i o n T
O W
N
H u e r f a
T
N a g e e z i
N w
M x i c o
E A
S T
E R
N
N
A V
A J O
W
A T
E R
P
I P
E L
I N
E
C U
T T
L
T
E R
H A
S
A
N
J U
C
U
N T
Y
X
I C
O
September 11, 2014
J T
N A
S B
U I
V
I S
I O
N
RECORD
DRAWING
10A
R- 9- W
R- -W
Se c
Se c
Lot 3Lot
Lo t
1" = 100'
1" = 10'
1" = 100'
1" = 10'
JGG/JEG
Ph on e (5
) 2
-0
T ol l-F re e (8
) 2
-0
F ax
(5
) 2
-3 w w w .so ud er m ill er .c om
A lb uq ue rq ue
, F ar m in gt on
, L as
C ru ce s, R os w el l, Sa nt a
Fe , N
M
El P as o, T X
C or te z
- G ra nd Ju nc tio n
- M on tro se , C
O
Sa ff or d, A Z
- M on tic el lo , U
T
Se rv in g th e
So ut hw es t & R oc ky
M ou nt ai ns
SO
U
D
ER
, M
IL
LE
R
A
SS
O
C
IA
TE
S
Sheet:
Horiz:Scale:
Project No:
Vert:
Date:
C h k d
B y
D e s c r i p t i o n
D a t e
R e v i s i
C A
N D
EL
A
R
IA
R O
A D
N E, S U
IT
E
D A
LB
U
Q U
ER
Q
U E, N M
P:\6- Cutter Ph 3 (6418285)\Acad\RECORD DWGS\Construction Dwgs\Recd_for_pdf\Cutter Ph 3 PnP - (2)-RECD.dwg , 9/11/2014 12:40:07 PM jtn© Copyright 2012 Souder, Miller & Associates - All Rights Reserved
6418285
C L
I E
N T
T v a t i o n T
O W
N
H u e r f a
N a g e e z i
N x i c o
E A
S T
E R
N
N
A V
A
T
P
E L
I N
E
C U
T T
T
E R
H A
A
N
J U
U
N T
X
I C
O
October 7, 2013
J T
N A
S B
U I
V
I S
I O
N
RECORD
DRAWING
10B
EXIST. TANK #1
100,000 GALLONS
27' Dia. x 24' Ht.
BASE ELEV. 6984.00
OVERFLOW ELEV. 7008.00
EXIST. TANK #2
100,000 GALLONS
27' Dia. x 24' Ht.
BASE ELEV. 6984.00
OVERFLOW ELEV. 7008.00
TANK SIDEWALL FLOOR
PENETRATION
W/ FREEZE BOX
(SEE DETAIL DT-23)
TANK #2
FEED
TANK #1 FEED
FLOW
BYPASS
LINE
FLOW
RECIRCULATION LINE
TANK
BYPASS
TO 22"
TRANSMISSION
LINE
TANK BYPASS
TO CHLOR.
FLOW
PROPOSED TANK
100,000 GALLONS
24' Dia. x 30' Ht.
BASE ELEV. 6984.00 6983.98
OVERFLOW ELEV. 7014.00
( SEE TANK DETAILS DT-21 thru DT-23 )
F L O
W
5'
TANK SIDEWALL
FLOOR
PENETRATION
W/ FREEZE BOX
(SEE DETAIL DT-23)
F L O
W
F
L
O
W
F L O
W
TIE-INTO EXIST. 6" PVC WATERLINE
REMOVE EXIST. 6" 90° ELL
REPLACE EXISTING TRANSDUCER AND
INSTALL CONDUIT TO CHLORINATION BLDG.
( SEE ELECTRICAL SITE PLAN AND DETAILS )
MAIN
FEED
FLOW
FUTURE WATERLINE
(BY OTHERS)
MULTI-DRAIN RIP-RAP SPLASH PAD
W/ (1) 18" FLAPPER, (1) 8" FLAPPER AND (2) 4" FLAPPERS
SIZE AND LOCATION TO BE DETERMINED BY FIELD ENGINEER
( SEE DETAIL DT-2 )
L
I
M
I
F
K
B
U
N
D
A
R
Y
U
N
F
E
N
C
E
D
S
T
U
H
N
E
G
R
A
D
Y
L
I
G
H
T
A
N
E
G
R
A
Y
L
I
G
H
T
P
R
O
P
O
S
E
D
I
V
E
W
A
Y
1" STEEL
SENSOR LINE
PROPOSED 8' HIGH FENCE, 266 LF ±
( SEE FENCE DETAIL DT-29 )
T
A
S
C
H
A
R
G
E
P
E
L
I N
E
L
O
B
D
G
A
N
E
S
G
R
A
Y
L
I
G
H
T
1" YARD HYDRANT, FROST FREE
(SEE DETAIL DT-2)
PROPOSED PRE-CAST 2 ROOM
CHLORINATION BUILDING
14'-8" x 9'-0"
BLDG. F.F. ELEV. 6979.50 6982.73
( SEE DETAILS DT-25, DT-27 and DT-28 )
125'
67.16'
LOCKABLE
VALVE BOX LID
TEMP. CONST. ESMT.
TO ACCOMMODATE RIP-RAP
TEMPORARY
TANK HOOK UP
Ph on e (5
) 2
-0
T ol l-F re e (8
) 2
-0
F ax
(5
) 2
-3 w w w .so ud er m ill er .c om
A lb uq ue rq ue
, F ar m in gt on
, L as
C ru ce s, R os w el l, Sa nt a
Fe , N
M
El P as o, T X
C or te z
- G ra nd Ju nc tio n
- M on tro se , C
O
Sa ff or d, A Z
- M on tic el lo , U
T
Se rv in g th e
So ut hw es t & R oc ky
M ou nt ai ns
SO
U
D
ER
, M
IL
LE
R
A
SS
O
C
IA
TE
S
Sheet:
Horiz:Scale:
Project No:
Vert:
Date:
C h k d
B y
D e s c r i p t i o n
D a t e
R e v i s i
C A
N D
EL
A
R
IA
R O
A D
N E, S U
IT
E
D A
LB
U
Q U
ER
Q
U E, N M
P:\6- Cutter Ph 3 (6418285)\Acad\RECORD DWGS\Construction Dwgs\Cutter Ph 3 DZ Tank Site Plan.dwg , 9/11/2014 12:47:35 PM mvh© Copyright 2012 Souder, Miller & Associates - All Rights Reserved
6418285
C L
I E
N T
T v a t i o n T
O W
N
H u e r f a
N a g e e z i
N x i c o
E A
S T
E R
N
N
A V
A
T
P
E L
I N
E
C U
T T
T
E R
H A
A
N
J U
U
N T
X
I C
O
September 11, 2014
J T
N A
S B
U I
V
I S
I O
N
RECORD
DRAWING
1" = 10'
N/A
A S
B
U I L
T
D
Z
T
A N
P
I N
G
P
L A
N
NOTES:
1. TANK ELEVATIONS MAY DIFFER FROM NTUA RECORD DRAWINGS.
2. PROVIDE BUILDING AND TANK SUB-FOUNDATIONS AND SITE GRADING IN ACCORDANCE WITH
GEOTECHNICAL REPORT.
3. PROVIDE TANK FOUNDATION IN ACCORDANCE WITH GEOTECHNICAL REPORT AND TANK
MANUFACTURER'S PE-SEALED FOUNDATION DESIGN.
4. TANK SIDE WALL TAPS SHALL BE PERFORMED DRY. CONTRACTOR SHALL DRAIN TANKS PRIOR TO
TAPPING AND SHALL REMOVE AND REPLACE EXISTING PAINT DAMAGED DURING WELDING TO MEET
ORIGINAL PAINT CONDITIONS. NO BARE METAL SHALL BE LEFT IN CONTACT WITH WATER. TANKS
SHALL BE DISINFECTED AS NEEDED AFTER TAPPING. "HOT TAPPING" SHALL NOT BE ALLOWED.
5. ALL VALVE CONCRETE COLLARS SHALL BE SCRIBED WITH ARROWS INDICATING FLOW PATH, PIPE
SIZE & VALVE FUNCTION ( I.E., PUMP INLET, TANK OUTLET, BLOWOFF, ETC.)
6. ALL VALVE COVERS SHALL BE PAINTED BLUE AND BE LABELED "WATER".
7. ALL BUTTERFLY VALVES SHALL BE LOCATED AT LEAST THREE (3) FEET AWAY FROM ANY OTHER
FITTING.
8. DO NOT INSTALL PIPE WITH ANY HIGH POINTS WITHOUT AN APPROVED AIR VALVE.
9. ALL BURIED ELBOWS UNDER BUILDINGS AND TANKS SHALL HAVE THRUST BLOCKS (SEE SHEET DT-3
FOR DETAILS AND DIMENSIONS).
10. ALL DRESSER COUPLINGS SHALL HAVE A 1”-2” GAP BETWEEN PIPE ENDS INSIDE COUPLING TO
FACILITATE DISASSEMBLY OF ADJACENT FLANGES.
11. ALL BURIED METALLIC COMPONENTS, INCLUDING PIPES, FITTINGS, VALVES, COUPLINGS, ETC. SHALL
BE CATHODICALLY PROTECTED. ELECTRICALLY ISOLATE ALL TANK AND BUILDING CONNECTIONS IN
ACCORDANCE WITH CATHODIC PROTECTION SYSTEM DESIGN. CP SYSTEM DESIGN TO BE PROVIDED
BY CONTRACTOR, PER SPECIFICATIONS.
12. ALL HDPE MATERIALS, FITTINGS AND APPURTENANCES SHALL BE RATED TO AT LEAST THE
PRESSURE OF THE MAIN LINE. ALL METALLIC PIPE, FITTINGS, VALVES AND APPURTENANCES SHALL
BE RATED TO AT LEAST 1.5 TIMES WORKING PRESSURE OF THE HDPE MAIN LINE.
13. ALL STEEL PIPE AND FITTINGS SHALL BE STANDARD WALL THICKNESS UNLESS OTHERWISE NOTED.
14. ALL BURIED STEEL PIPE SHALL BE COLD-APPLIED TAPE COATED AND FUSION-BONDED EPOXY
COATED, PER SPECIFICATIONS.
15. ALL STEEL PIPE AND FITTINGS UNDERNEATH AND WITHIN 5' OF TANKS OR BUILDINGS SHALL BE
SHOP WELDED AND COATED, X-RAY TESTED AND PRESSURE TESTED PRIOR TO POURING
FOUNDATIONS. SHOP COATING SHALL BE APPLIED AFTER WELDING.
16. ALL STEEL PIPE AND FITTINGS BEYOND TANK AND BUILDING FOUNDATIONS SHALL BE SHOP- OR
FIELD-WELDED UNLESS OTHERWISE NOTED. ALL FIELD-WELDED PIPES AND FITTINGS SHALL BE
RE-COATED PER SPECIFICATIONS AFTER WELDING.
KEYED NOTES - DZ TANK SITE
Item
No.
Description
3" VACUUM BREAKER W/ 2" ARV ASSEMBLY ( SEE DETAIL DT-9 )
CONCRETE WALL ANCHOR ( SEE DT-3 )
18" x 22" HDPE CONCENTRIC REDUCER, PE4710, PC 125 IPS
18" HDPE FLANGE ADAPTER, PE4710, PC 125 IPS W/ STEEL BACK UP RING
5 18" STEEL TEE
18" DRESSER COUPLING, 250 psi MINIMUM
18" FL x FL BUTTERFLY VALVE, 250 psi ( SEE DETAIL DT-7 )
8 18" STEEL FLANGE ANSI CLASS 150
18" HDPE 22.5° ELL PE4710, PC125 IPS
10 18" 90° STEEL ELL
11 18" x 18" STEEL CROSS
12 18" STEEL BLIND FLANGE
13 18" x 8" STEEL CONCENTRIC REDUCER
8" FL x FL GATE VALVE ( SEE DETAIL DT-7 )
15 8" STEEL FLANGE
16 8" 90° STEEL ELL
17 8" STEEL TEE
18 8" x 8" STEEL CROSS
19 8" x 6" STEEL CONCENTRIC REDUCER
20 6" MJ D.I. TEE
21 4" 45° STEEL ELL
TRANSDUCER / VAULT ( SEE ELECTRICAL DETAILS )
8" CHECK VALVE / VAULT ( SEE DETAIL DT-11 )
THRUST BLOCK ( SEE DETAIL DT-3 )
22" HDPE PE4710, DR17 IPS PIPE
26 18" STEEL PIPE
27 8" STEEL PIPE
28 6" STEEL PIPE
29 6" MJ FLANGE ADAPTOR
30 4" STEEL PIPE
6" MJ x MJ GATE VALVE ( SEE DETAIL DT-7 )
6" MECHANICAL JOINT RESTRAINT, MEGA-LUG, OAE, 250 psi
8" DRESSER COUPLING ( 250 psi MINIMUM )
34 18" x 1" TAPPING SADDLE W/ 1" CORP STOP FOR 1" SENSOR LINE
36 8" 45° STEEL ELL
37 8" x 1" TAPPING SADDLE
38 4" PVC DR18 PIPE
39 8" PVC DR18 PIPE
40 18" PVC DR18 PIPE
41 18" MJ x MJ DI 90° ELL
42 18" MJ x MJ DI TEE
43 4" MJ x MJ DI 45° ELL
44 8" MJ x MJ DI 45° ELL
45 18" MJ x MJ TEE
46 18" MJ x MJ 45° ELL
NOTE:
FIELD LOCATE CONDUITS PER
REVIEW WITH ELECTRICIAN
NOTE:
CONTRACTOR RESPONSIBLE TO VERIFY AND
ALIGN ACTUAL FOUNDATION DIMENSIONS
AND LOCATIONS OF EXISTING TANK PIPING
INLETS, OUTLETS AND DRAINS IN THE FIELD
SIGN TO BE POSTED
ON ENTRY GATE
10C