Questions_and_Answers_Report.pdf

PDF 3 MB Posted

Attached to
E-RATE CATEGORY 2
Solicitation number
2026-10-652
Issued by
Collin County, Texas

About this file

This Questions and Answers Report document pertains to McKinney Independent School District's E-Rate Category 2 solicitation for internal connections infrastructure across 19 school facilities in Texas. The District is soliciting proposals for structured cabling, network switches, wireless access points, and uninterruptible power supply (UPS)/battery backup units to support the District's participation in the Federal Communications Commission's E-Rate Program. Proposals are due December 11, 2026 at 2:00 p.m., with non-mandatory pre-proposal site visits scheduled for November 5 and 6, 2026. The question submission deadline is November 13, 2026 at 10:00 a.m., with responses due November 17 at 5:00 p.m. The anticipated board meeting is January 19, 2027, with anticipated award on January 20, 2027. The contract term runs April 1, 2027 through September 30, 2028, with one optional renewal period aligned with extended E-Rate service delivery deadlines. Substantial installation completion is targeted for July 24, 2027, with specific installations at Minshew Elementary and Boyd High School commencing May 27, 2027, and UPS equipment installations at remaining locations commencing June 1, 2027.

Qualified vendors must demonstrate at least three years of comparable service experience, possess a valid FCC Service Provider Identification Number (SPIN/498 ID), demonstrate E-Rate program compliance knowledge, provide technical capability to support enterprise networks, maintain operational capacity at all District locations, demonstrate financial stability, and provide satisfactory references from K-12 school districts. All equipment must be new and commercially available, not end-of-life or end-of-support at installation. Required specifications include enterprise-class managed Ethernet network switches with 60-month license and subscription terms, Wi-Fi 7 wireless access points with cloud-based management and 60-month subscription terms, line-interactive or online double-conversion UPS systems with lithium-ion batteries, and structured cabling compliant with TIA/EIA-568B standards featuring Category 6A copper horizontal cabling with a 25-year application assurance warranty. The District reserves the right to make single or multiple awards by category, and all costs for compliance, installation, configuration, testing, and specification deviations are the proposer's sole responsibility. No pricing terms, set-asides, or specific funding amounts are detailed in this Questions and Answers Report.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

McKinney Independent School District, TX

Procurement Laura Duree, Director of Purchasing

1 Duvall St, Mckinney, TX 75069

(972) 542-7410

QUESTION & ANSWER REPORT

Request For Proposal - E-RATE CATEGORY 2

QUESTION & ANSWER REPORT

RFP No. 2026-10-652

E-RATE CATEGORY 2

RESPONSE DEADLINE: December 11, 2026 at 2:00 pm

Tuesday, November 17, 2026

Approved, Unanswered Questions

Approved, Answers Provided

1. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 37

Nov 2, 2026 8:50 AM

Question: The McKinney ISD Approved Parts List includes Door Hinges, Cage Nuts/Screws and Cable Management Chases. Please provide quantities we need to include within our proposal for these items.

Nov 2, 2026 8:50 AM

Answered by Stephen McGilvray: The McKinney ISD Approved Parts List is a list of approved parts or equivalent. Refer to the rack elevations for each network closet in the supporting attachment of the RFP to determine the parts and accessories needed.

Nov 17, 2026 9:50 AM

2. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 39

Nov 2, 2026 8:50 AM

Question: The McKinney ISD Approved parts list includes Panduit Wire Basket Tray and related items. Is it acceptable to utilize a different manufacturer such as Cablofil, WBT, Basor, etc. in lieu of Panduit?

Nov 2, 2026 8:50 AM

Answered by Stephen McGilvray: The specifications list all Panduit items or equivalent. This is also referenced in the MCKINNEY ISD APPROVED PARTS LIST OR EQUIVALENT section. All equivalent manufacturer part numbers will be considered. Please provide specifications detailing how the part is equivalent to the part listed.

RFP No. 2026-10-652

3. E-Rate_Category_2_(Addendum_#1_Revision) Document

Nov 2, 2026 8:51 AM

Question: Page 41 installation specifications indicates we are to run 18/2 between extension speakers and close IP ceiling speakers. Please provide drawings indicating the Extension Speakers and close IP ceiling speaker locations, or provide an estimated distance for cable & supports allocation.

Nov 2, 2026 8:51 AM

Answered by Laura Duree: The speaker & extension speaker locations will be provided in an addendum.

MCKINNEY BOYD HIGH SCHOOL FLOOR 1:

MCKINNEY BOYD HIGH SCHOOL FLOOR 2

MINSHEW ELEMENTARY

4. E-Rate_Category_2_(Addendum_#1_Revision) Document

Question: Page 41 lists items to support Badge Readers, DPI Sensors and Lockdown buttons. Please provide drawings indicating their end device locations, or provide and estimated distance for Cable & Supports allocation.

Answered by Laura Duree: Badge readers, DPI Sensor, & Lockdown Button Locations will be provided in an addendum.

MCKINNEY BOYD HIGH SCHOOL FLOOR 1

5. E-Rate_Category_2_(Addendum_#1_Revision) Document

Question: Please confirm that we need to include (1) 24-Strand fiber from the MDF to each of the identified IDF's at Minshew ES & Boyd HS Phase 3

Answered by Stephen McGilvray: Yes. Please refer to 3.14. STRUCTURED CABLING SPECIFICATIONS, INSTALLATION SPECIFICATIONS, bullet C.

6. E-Rate_Category_2_(Addendum_#1_Revision) Document

Nov 2, 2026 8:52 AM

Question: Please confirm the AT&T Dmarc Location shown on Page 11 of the supporting attachments is the only DMARC for Minshew ES for the requested Cat3 25 Pair Feeder Cable

Nov 2, 2026 8:52 AM

Answered by Stephen McGilvray: That is correct as per the documentation.

7. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 39

Question: Is there desired cable jacket colors for the required 18/2, 18/4 and composite cable? Is the cable to be Plenum or Riser Rated?

Nov 2, 2026 8:52 AM

Answered by Stephen McGilvray: Composite cable is yellow. 18/2 & 18/4 cable is white. The cable should be plenum rated.

8. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 42, Line O

Question: There are no mentioned requirements for sleeve pathways going into non-classroom rooms.

Is it acceptable to utilize 1" minimum sized Sleeves for non-classroom rooms?

Nov 2, 2026 8:52 AM

Answered by Stephen McGilvray: No, we want the 2" sleeve for non-classroom rooms.

9. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 42, Line N

Nov 2, 2026 8:53 AM

Question: Please confirm if Minshew ES has existing overhead cable tray that can be used for new horizontal category/fiber cabling.

Answered by Stephen McGilvray: Typically, there is existing overhead cable tray that can be used, but if there is not, it needs to be included in your proposal.

10. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 42, Line N

Question: Please confirm if Boyd HS Phase 3 has existing overhead cable tray that can be used for new horizontal category/fiber cabling.

Nov 2, 2026 8:53 AM

Answered by Stephen McGilvray: Typically, there is existing overhead cable tray that can be used, but if there is not, it needs to be included in your proposal.

11. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 42, Line N

Question: The requirement states that if no cable tray exists, the proposer will install 4"x12" Cable tray.

To ensure even bids from all participating vendors, can you please provide a drawing showing the desired routing and location for the tray for both schools?

Nov 2, 2026 8:53 AM

Answered by Stephen McGilvray: The desired cable pathway should follow the hallways and corridors for each school.

12. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 32

Question: The required patch cord breakdown does not account for a total of (2) Patch Cords per cable segment installed. Please confirm the patch cord requirements for both schools.

Nov 2, 2026 8:53 AM

Answered by Stephen McGilvray: In the patch cord section, Item A accounts for the patch cord in the MDF/IDF closet side for the switch ports. Items B-H accounts for the 2nd patch cord on the device side.

13. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 32

Nov 2, 2026 8:54 AM

Question: For the MDF to IDF Backbone fiber cabling from the MDF to each IDF at Boyd HS, Please clarify on the intent to get cabling between floors.

Nov 2, 2026 8:54 AM

Answered by Stephen McGilvray: The network closets at Boyd HS - Phase 3 have existing pathways between floors. The new cabling will run within these pathways.

14. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 32

Nov 2, 2026 8:54 AM

Question: Can you provide a to-scale overall drawing for each floor at Boyd HS to accurately calculate backbone fiber footages?

Nov 2, 2026 8:54 AM

Answered by Stephen McGilvray: Refer to the addendum section: FLOOR PLANS

MCKINNEY BOYD HIGH SCHOOL FLOOR 2:

15. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 32

Nov 2, 2026 8:54 AM

Question: Do we need to include demo of existing structured cabling or fiber at Minshew ES?

Nov 2, 2026 8:54 AM

Answered by Stephen McGilvray: No.

16. E-Rate_Category_2_(Addendum_#1_Revision) Document, Page 32

Nov 2, 2026 8:55 AM

Question: Do we need to include any demo of existing structured cabling or fiber at Boyd HS?

Nov 2, 2026 8:55 AM

Answered by Stephen McGilvray: No.

17. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: The overhead ladder rack shown in Mindshew MDF B104 appears to have two different sizes.

The approved material list only indicates 12". Please provide clarity on what size ladder rack is desired.

Nov 2, 2026 8:55 AM

Answered by Stephen McGilvray: All ladder rack should be 12".

18. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: Please confirm if we need to include any surface mount raceway or surface mounted conduit to support category 6A outlets.

Nov 2, 2026 8:55 AM

Answered by Stephen McGilvray: Surface mounted raceway or conduit should be included for network drops that are on cinderblock or brick walls that do not already have existing raceway or conduit.

19. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Nov 2, 2026 8:56 AM

Question: Please clarify when work is allowed to be done. (During normal business Hours, Overnight, Weekends, School Break, Etc.)

Nov 2, 2026 8:56 AM

Answered by Stephen McGilvray: Project business hours are defined as 7:00 AM to 6:00 PM, weekdays, weekends, and holidays.

20. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: Please provide a breakdown of the Speaker, Strobe, Clock devices indicated on the cable Matrix Drop counts for each of the 2 schools.

Nov 2, 2026 8:56 AM

Answered by Stephen McGilvray: The speaker, strobe, and clock devices are all IP based and need a single Cat6A drop per the requested quantity in the matrix.

21. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: Please clarify who is responsible for providing and installing the telecommunications bonding busbar for each IDF/MDF room.

Nov 2, 2026 8:56 AM

Answered by Stephen McGilvray: The grounding bus bar for each MDF/IDF room will be installed by others.

22. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Nov 2, 2026 8:57 AM

Question: Do we need to include any fiber patch cords to support the new 24-strand Singlemode fiber segments running to each IDF from the MDF room?

Nov 2, 2026 8:57 AM

Answered by Stephen McGilvray: The District will provide the fiber patch cords.

23. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: Can we use 24-Fiber, 12-Duplex LC Singlemode fiber adapter panels in lieu of (2) 12-Fiber, 6- Duplex LC Singlemode fiber adapter panels for each end of the fiber backbone cables?

Answered by Stephen McGilvray: Yes.

24. McKinney_ISD_E-Rate_Category_2_RFP_Supporting_Attachment, Page 11

Question: Is it acceptable to provide pricing for a UPS/PDU Manufacturer other than APC?

Nov 2, 2026 8:57 AM

Answered by Stephen McGilvray: Yes.

25. E-Rate_Category_2_(Addendum_#1_Revision) Document

Question: Please confirm if we need to include labor to install owner furnished wall phones at all new outlet locations

Nov 2, 2026 8:52 AM

Answered by Stephen McGilvray: No

26. 3.14. STRUCTURED CABLING SPECIFICATIONS

Nov 6, 2026 10:13 AM

Question: For the horizontal cabling, would you be open to giving Belden an opportunity to compete with Panduit on this project? We can offer a high-quality, reliable solution with competitive project pricing and strong product availability to help keep the project on schedule.

Nov 6, 2026 10:13 AM

Answered by Stephen McGilvray: The specifications list all Panduit items or equivalent. This is also referenced in the MCKINNEY ISD APPROVED PARTS LIST OR EQUIVALENT section. All equivalent manufacturer part numbers will be considered. Please provide specifications detailing how the part is equivalent to the part listed.

27. No subject

Nov 12, 2026 10:50 AM

Question: For a company formed in 2026, may the three-year comparable-experience requirement be satisfied through the documented experience of the company's principal/owner and/or a named installation subcontractor, or must the proposing legal entity itself have three years of service history?

Nov 12, 2026 10:50 AM

Answered by Stephen McGilvray: The proposing legal entity must have three years of experience delivering comparable services of similar scope and complexity.

28. No subject

Question: Must the proposer's SPIN (FCC Form 498 ID) be active at proposal submission (December 11, 2026), or will the District accept a proposer whose Form 498 has been filed with USAC and whose SPIN is pending issuance, provided it is active before award/invoicing?

Nov 12, 2026 10:50 AM

Answered by Stephen McGilvray: Section 2.1 in the Proposer Submissions requires respondents to provide their FCC Registration Number (FRN) and E-Rate Service Provider Identification Number (SPIN / FCC Form 498 ID) at the time of submission. Proposals that omit required information may be deemed non-responsive per Section 2.3 of the Proposal Instructions.

29. No subject

Question: If a proposer cannot supply three current school-district customers, may references be the principal's prior-project references from previous employment, or customers of a named subcontractor?

Nov 12, 2026 10:50 AM

Answered by Laura Duree: References should be for the proposing firm. If the proposer is unable to provide three current school district customers, the proposer may provide three current customer references as permitted by the solicitation. References from previous employers of key personnel or from subcontractors do not satisfy the reference requirement for the proposing firm.

30. No subject

Nov 12, 2026 10:51 AM

Question: Is a bid bond via Surety2000 required for a partial (structured-cabling-only) proposal, and if so, at what amount or percentage? For the 100% performance/payment bonds due on award, what equivalent financial assurances has the District accepted in the past?

Nov 12, 2026 10:51 AM

Answered by Laura Duree: For proposals including structured cabling work, a bid bond is required through Surety2000 as indicated in Section 1.6. The required bid security is 5% of the proposal amount.

For performance and payment bond requirements that may be imposed upon award pursuant to Section 1.5, proposers unable to provide the required bond may submit proposed equivalent financial assurances for District review and approval in accordance with Section 1.5.1 (available once "no" is selected on 1.5. The District may consider alternatives, including a cashier's check, as an equivalent financial assurance; however, acceptance is subject to District review and approval.

31. No subject

Question: For a newly formed company that cannot provide three fiscal years of audited financial statements, what alternative demonstration of financial capacity will the District accept (e.g., bank references, reviewed statements for the period since formation, owner financial statement)?

Nov 12, 2026 10:50 AM

Answered by Stacey Stanfield: Please provide audited financial statements for as many years as you have been in business. If you have been in business less than one year, please send the most current financials.

32. No subject

Question: If a proposal names an experienced installation subcontractor under a primary proposer, will the subcontractor's experience, references, and E-Rate compliance record be evaluated toward the Section 3.7 minimum qualifications?

Nov 12, 2026 10:51 AM

Answered by Stephen McGilvray: No, the subcontractor's experiences, references, and E-Rate compliance record will not meet requirements for this RFP.

33. No subject

Question: Will the District hold any additional cabling site visits before December 11 for proposers who did not attend the November 5-6 visits, or is site-visit attendance closed?

Nov 12, 2026 10:51 AM

Answered by Debbie Paulsen: There will be no additional site visit held.

34. Battery packs per UPS

Nov 12, 2026 3:34 PM

Question: The pricing form lists 200 UPS units (22 × SRTL3KRM1UNC and 178 × SRTL2K2RM1UNC) and 600 external battery packs (SRTL50RMBP1U-LI). Please confirm that the District intends three external battery packs per UPS at every location. If the count varies by site or closet, please give the quantity per UPS model or per location.

Nov 12, 2026 3:34 PM

Answered by Stephen McGilvray: On average, each UPS will have (3) battery packs connected. Smaller network closets with 1-2 switches have two battery packs, closets with 3-4 switches have three battery packs, closets with 5-6 switches have four battery packs, and closets with 7+ switches have 5 battery packs.

35. UPS runtime

Nov 12, 2026 3:35 PM

Question: What runtime is the District looking for at each closet, and at roughly what load (watts or percentage of UPS capacity)?

Nov 12, 2026 3:35 PM

Answered by Stephen McGilvray: Based on the switch counts per closet mentioned above, the District targets one hour runtime based on the historical load.

36. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:34 PM

Question: There is no call out for cabinets in the MDF?

Nov 13, 2026 2:34 PM

Answered by Stephen McGilvray: No, the MDF was renovated as part of Phase 2. Only SM fiber running from the MDF to the IDF locations are included in the phase 3 project.

37. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:35 PM

Question: What type of fiber is in here already?

Nov 13, 2026 2:35 PM

Answered by Stephen McGilvray: 24 Strand Fiber Cable, OS2, Indoor Armored, Plenum, 900µm Single-mode

38. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Are we responsible for the removal of the old stuff?

Nov 13, 2026 2:35 PM

Answered by Stephen McGilvray: No, this proposal only covers the new installation covered in the RFP.

39. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: We will just be pulling new cables?

Nov 13, 2026 2:35 PM

Answered by Stephen McGilvray: Yes, along with the build out of the network closet items covered in the RFP.

40. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:36 PM

Question: How familiar are we with the pathways in the building?

Answered by Stephen McGilvray: Somewhat familiar, but the ceiling tiles will be completely removed to expose all pathways.

41. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Are we going to stick to existing pathways, or new pathways?

Nov 13, 2026 2:36 PM

Answered by Stephen McGilvray: Existing pathways, when possible, but new pathways can be created if it is accounted for in your proposal.

42. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Will the existing cable already be pulled out when we start running the new cable?

Nov 13, 2026 2:36 PM

Answered by Stephen McGilvray: Yes, all old cabling will be removed before the new cable is run.

43. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:37 PM

Question: Are we keeping the existing racks from the IDF’s?

Nov 13, 2026 2:37 PM

Answered by Stephen McGilvray: All proposals need to include new racks to keep all bids consistent.

44. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Are bidders responsible for removing all existing cables?

Nov 13, 2026 2:37 PM

Answered by Stephen McGilvray: No, that will be handled separately from this proposal.

45. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Would you like bidders to have an alternate proposal to remove the existing cable?

Nov 13, 2026 2:37 PM

Answered by Stephen McGilvray: No, there will be another opportunity to provide proposals for the removal of the existing cable.

46. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:38 PM

Question: Will everything in this room be gutted?

Nov 13, 2026 2:38 PM

Answered by Stephen McGilvray: Yes

47. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Where are the cinderblock walls in the building?

Nov 13, 2026 2:38 PM

Answered by Stephen McGilvray: There are cinderblock walls in most parts of the building, but it is not every wall.

48. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Is there cinderblock between classrooms?

Nov 13, 2026 2:38 PM

Answered by Stephen McGilvray: Yes, in some classroom spaces there may be cinderblock.

49. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:39 PM

Question: Can we see inside a classroom?

Nov 13, 2026 2:39 PM

Answered by Stephen McGilvray: Yes, any classroom that is open can be looked at.

50. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:39 PM

Question: Data cables for the TVs, I assume each one is getting a data cable?

Nov 13, 2026 2:39 PM

Answered by Stephen McGilvray: No, we are moving them to wireless.

51. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:39 PM

Question: I was asking to see if we needed to take the TV down?

Nov 13, 2026 2:39 PM

Answered by Stephen McGilvray: No, the TVs and other technology items will already be removed before cabling install.

52. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:40 PM

Question: Access points and cameras, are we responsible for taking those down?

Nov 13, 2026 2:40 PM

Answered by Stephen McGilvray: No, these and other technology items will already be removed before cabling install.

53. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: When we pull cables to the APs and cameras, are we responsible for patching them in on the device side?

Nov 13, 2026 2:40 PM

Answered by Stephen McGilvray: The devices should not be installed before the new cabling is pulled. If the timeline of the project gets off and the device is installed before the cabling is run, we would like it to be connected to the device.

54. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: How often do you refresh schools?

Nov 13, 2026 2:40 PM

Answered by Stephen McGilvray: A 20-year cycle

55. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: What year was the building built?

Nov 13, 2026 2:40 PM

Answered by Stephen McGilvray: 2006

56. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:41 PM

Question: Will there be someone from the district in charge, or will there be a GC?

Nov 13, 2026 2:41 PM

Answered by Stephen McGilvray: A member of our facilities team will act as a GC but it is an MISD employee. We follow their schedule for when things can be done in a section of the building.

57. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Would bidder be able to put a storage container out onsite before the project starts?

Nov 13, 2026 2:41 PM

Answered by Stephen McGilvray: Yes

58. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Where are the speakers drops and extension speakers going?

Nov 13, 2026 2:41 PM

Answered by Laura Duree: The speaker & extension speaker locations will be provided in an addendum.

59. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:42 PM

Question: The speaker cables are the only non-ethernet cables being installed?

Answered by Stephen McGilvray: No, the access-controlled doors will need composite cables. There are other doors that are DPI sensor only that will not need the full composite cable but will need the 18/4 cable. The door locations will be provided in an addendum.

MCKINNEY BOYD HIGH SCHOOL FLOOR 1

60. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: For the IDFs are bidders proposing the wall cabinet, 2 post racks ,etc.?

Answered by Stephen McGilvray: Yes, the bid will need to include a full buildout, as if there was no existing hardware.

61. Question from McKinney Boyd High School Pre-Proposal Site Visit

Question: Are bidders re-cabling access control and reconnecting those doors?

Nov 13, 2026 2:42 PM

Answered by Stephen McGilvray: Bidders are only getting the specified cable in the BOM to the location of the door, speaker, DPI sensor, etc. The installation of the speakers, access points, etc. are not part of this proposal.

62. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:43 PM

Question: Has the proposal for installation of the technology items already been sent out?

Nov 13, 2026 2:43 PM

Answered by Stephen McGilvray: No, it has not.

63. Question from McKinney Boyd High School Pre-Proposal Site Visit

Nov 13, 2026 2:43 PM

Question: Will the separate proposals be sent out to those who respond to this bid? Or do they need to keep an eye out on the site for another post?

Nov 13, 2026 2:43 PM

Answered by Stephen McGilvray: We will make sure those opportunities are sent out to all responders.

64. Question from Minshew Elementary Pre-Proposal Site Visit

Nov 13, 2026 2:44 PM

Question: Room D113 is being converted into an IDF?

Answered by Stephen McGilvray: Yes, this is a storage closet today that will be converted to an IDF during the renovations.

65. Question from Minshew Elementary Pre-Proposal Site Visit

Question: Are bidders pulling security camera wiring and access control?

Nov 13, 2026 2:44 PM

Answered by Stephen McGilvray: Yes, this is for all cabling in the building.

66. Question from Minshew Elementary Pre-Proposal Site Visit

Question: Is there a basket tray for pathways?

Nov 13, 2026 2:44 PM

Answered by Stephen McGilvray: Typically yes, but if there is not, it needs to be included in your proposal.

QUESTION & ANSWER REPORT
RFP No. 2026-10-652 E-RATE CATEGORY 2
RESPONSE DEADLINE: December 11, 2026 at 2:00 pm
Approved, Unanswered Questions
Approved, Answers Provided

File details come from the government source that posted it. Updated .