PWS - FY21 Hoods Ducts - 4 Aug 20 (revised).pdf

PDF 146 KB Posted

Attached to
Hoods and Ducts Maintenance Federal contract opportunity
Solicitation number
FA487720R0043
Issued by
Department of the Air Force Air Combat Command

About this file

This combined synopsis/solicitation from the Department of the Air Force Air Combat Command requests fixed-price proposals for hoods and ducts maintenance services at Davis-Monthan Air Force Base in Arizona. The services include cleaning cooking hoods, paint/saw systems, and dryer vents over five option years from FY21 to FY25. Offerors must provide their method for performing cleaning processes and address the performance work statement requirements. Award will be made to the lowest priced technically acceptable offeror meeting the small business set-aside requirements. Proposals are due by September 8, 2020. A site visit will be held on August 27, 2020 and post-visit questions are due by August 28, 2020.

View the file

Other files for this federal contract opportunity

Other files attached to Hoods and Ducts Maintenance, newest first.
File Type Posted
PWS - FY21 Hoods Ducts - 28 Aug 20 (revised).pdf PDF
Hoods and Ducts QA.pdf PDF
WD 15-5473 Rev 10.pdf PDF
Contractor Environmental Guide.pdf PDF
MFR Pandemic Guidance - Hoods and Ducts.pdf PDF
FA487720R0043 - Provisions and Clauses.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

17 AUGUST 2020 1 | P a g e

Performance Work Statement (PWS) For

Hoods, Ducts and Exhausts Cleaning Services

Objective. Service hoods, ducts, and exhaust cleaning systems.

1.0. Description of Services. The contractor shall furnish all labor, parts, tools, materials, equipment, transportation, personnel, management, and supervision necessary to clean all cooking, paint booth, and dryer exhausts and ducts listed in appendix 2 of this Performance Work Statement (PWS), at Davis- Monthan AFB (DMAFB), AZ.

1.0.1. Definitions.

Cooking Exhausts & Ducts

The air duct, vertical and horizontal, conveying grease, or smoke laden air, and extending from the throat of the canopy or range hood through the roof or exterior wall to the outside atmosphere, and ventilation fans located in kitchens and dining areas

Dryer Vents The air duct, vertical and horizontal, conveying clothing lint, and extending from the backside of the appliance through the roof or exterior wall to the outside atmosphere, and vent covers.

Systems Any of the cooking, dryer exhausts, and ducts defined in PWS paragraph 1.1.2.

Paint Booth & Wood Exhaust Systems

The air duct, vertical and horizontal, conveying paint, fumes, or sawdust-laden air extending from the filter through the roof or exterior wall to the outside atmosphere.

1.1. Schedule of Services. The contractor shall contact the Government Contracting Officer Representative (COR) within one week after notification of contract award to provide written schedule of services as necessary, nights and weekends included. In the event that a schedule, satisfactory to COR and the contractor, cannot be developed, the COR will notify the Contracting Officer (CO) for resolution. Any changes to the scheduled dates shall be provided (e-mailed or called in) to the COR no later than 2 weeks before the scheduled service date.

1.2. Dryer and Cooking Exhausts, Ducts, and Fire Protection Systems. The contractor shall remove all grease, lint, or any other foreign material from dryer units, dryer and cooking exhausts, ducts, fire protection systems, and from behind and under fan motors. All debris shall be removed from the job, and placed in Government designated disposal containers at each building. After cleaning is complete, metal surfaces shall be completely free of the above-mentioned foreign material.

1.2.1. The contractor shall steam clean and treat the entire inside surface of the cooking duct, the underside of the range and hoods, all exposed surface of fans, motor housing, metal penthouses, louvers, and other appurtenances located inside the duct or penthouse, and louvers, at discharge of exhaust to atmosphere.

The contractor shall also clean the underside of hood and wall surface area.

17 AUGUST 2020 2 | P a g e

1.2.2. Clean-out plates (openings) and matching ductwork, necessary for the physical entry into aforementioned exhaust systems, shall be removed/replaced and sealed by the contractor, in accordance with National Fire Codes/Standards. All interior surfaces shall be manually cleaned, and treated. Louvers shall be removed, cleaned, and replaced, where necessary, to gain access to ducts or fans.

1.2.3. Cleaning Work Area. Immediately following completion of work, the contractor shall clean entire work areas, including the roof work location, to allow normal operations at each facility. The contractor shall also clean any run-off or spillage on sidewalks and parking areas.

1.2.4. Return Units to Operating State. When cleaning procedures are completed, the contractor shall return all systems and units to a 100% operating state (i.e. all electrical switches, detection devices, system supply cylinders, etc.). Cover plates shall be replaced, while dampers and diffusers shall be positioned for proper airflow. NOTE: If the contractor removes/relocates the cooking equipment, the contractor shall return the equipment to the original location and re-light pilot lights. The contractor must notify the facility manager or on-duty personnel prior to departure so they can verify pilots are relit.

1.2.5. Deficiency Reporting. The contractor shall immediately report all duct, fan, filter, or electrical deficiencies to the COR upon discovery by the contractor.

1.2.6. Government Inspection. The contractor shall call the Fire Prevention Office (FPO)/Fire Inspector (FI) 15 minutes before completion of work, so inspector can inspect hoods, ducts, and paint booths. The inspector will check compliance with the National Fire Protection Act standards. The Fire Inspector can be reached at (520) 228-6027/4333/4757.

1.2.7. Fire Suppression Systems Accidental Discharge. The contractor shall service fire suppression systems, in the event of accidental discharge due to work being performed by the contractor. Restoration of fire suppression systems shall only be performed by a qualified contractor, within 12 hours of the accidental discharge. The contractor shall immediately notify the COR and/or the FPO/FI in the event of accidental discharge of fire suppression systems.

1.3. Paint & Wood Exhaust. The contractor shall use a dry cleaning method to remove all grease, solvents, paint, or any other foreign material from exhausts and ducts. The contractor shall remove all debris from the job site and place it in Government designated containers at each building for proper disposal, in accordance with current environmental directives. After cleaning is complete, the surfaces shall be completely free of the above-mentioned foreign material.

1.3.1. Cleaning. The contractor shall clean the entire inside surface of the duct from the filter up (to include the frame, but not the filter), all exposed surfaces of fans, motors, housings, metal penthouses, louvers, other appurtenances located inside the duct or penthouse, and louvers, at discharge of exhaust to atmosphere. The contractor shall also clean exterior walls and/or road surfaces where paint, grease, or any other foreign material has collected at exhaust discharge, to the atmosphere.

1.3.2. Clean-out (openings) and matching ductwork necessary for the physical entry into the aforementioned exhaust system, shall be removed/replaced and sealed. All interior surfaces shall be manually cleaned. Louvers shall be removed and replaced, where necessary, to gain access to ducts or fans.

1.3.3. Work Area Clean Up. The contractor shall clean the entire work area immediately after completion of work to allow for normal operation of the facility.

1.3.4. Return Units to Operating State. When cleaning procedures are completed, the contractor shall return all units to an operating state (i.e. all-electrical switches; detection devices, system supply cylinders, 17 AUGUST 2020 3 | P a g e etc.). Cover plates shall be replaced, dampers, backflows, and diffusers shall be positioned for proper airflow.

1.3.5. Deficiency Reporting. The contractor shall immediately report all duct, fan, filter, or electrical deficiencies to the COR upon discovery by the contractor.

1.3.6. Government Inspection. Upon completion of work on each dryer exhaust system in each building, the contractor shall notify the COR that work is ready for inspection. The COR may inspect each exhaust system in each building at any time during or after the contractor has completed services.

2.0. Special Requirements

2.1. Continuation of Essential Contractor Services. The Government has determined that the services in this PWS are not mission essential and do not require continued support during crisis, as defined in accordance with the Defense Federal Acquisition Regulation Supplement (DFARS), Subpart 237.76, Continuation of Essential Contractor Services.

2.2. Contract Manager. Upon contract award, the contractor shall designate a primary contract manager and at least 1 alternate contract manager, who will be responsible for performance of services. The contractor shall submit the names and phone numbers of the primary contract manager and alternate(s), who shall act for the primary contract manager if absent, in writing to the CO and COR. The contract manager and alternate(s) shall have full authority to act for the contractor on all matters relating to daily operation of this contract. The contract manager or alternate(s) shall be available within 60 minutes, either in person or by telephone, during normal duty hours to discuss performance with Government personnel.

The contract manager and alternate(s) contract manager shall have a minimum of three years’ experience in work related to that which is being performed and must be able to read, write, speak, and understand English fluently.

2.2.1. Technician Requirements. The technician(s) working without the contract manager present shall have a minimum of two years’ experience in work related to the tasks being performed.

3.0. Services Summary

Performance Objectives PWS Paragraph Performance Threshold

1. Remove grease, lint and foreign material from duct and hood systems and components

1.2. through 1.2.2.

No more than 1 valid customer complaint per month

2. Clean work area and return all systems and units to a 100% operational state.

1.2.3. through 1.2.4,

1.3.3. through 1.3.4.

No more than 1 valid customer complaint per month

4.0. General Information

4.1. Listing of Employees. The contractor shall maintain a current listing of employees performing services on DMAFB. The list shall include employee's name (as shown on Driver’s License), social security number, driver’s license number, state of issue, date of birth, and country of citizenship. Managers, supervisors, and/or superintendents must be identified on the list of employees. The contractor shall submit

17 AUGUST 2020 4 | P a g e the list to the CO and the COR, prior to the contract start date, and submit an updated list when an employee's status or information changes, within 5 working days of the change. The name of any contractor employee that is terminated during the period of the contract must be reported to the COR in writing within one workday of the employee’s termination.

4.1.1. Access to the 309th Aerospace Maintenance and Regeneration Group (309 AMARG) Area. This project includes work located in the 309 AMARG controlled area. Strict security and personnel access control is maintained. Contractor personnel must be listed on an entry authorization list (EAL), have proper identification, and obtain passes at the 309 AMARG gate to obtain entry to the work site. New EAL requests (contractor employee names) must be submitted to the COR at least 48 hours in advance for required access to the site. The name of any employee that is terminated during the period of the contract must be reported in writing to the COR within one workday of the termination.

4.2. Security Training. All contractor employees shall receive initial and recurring security education training from the Government sponsoring agency’s security manager. Training must be conducted in accordance with DoD 5200.01 V1-V4, Information Security Program, and AFI 31-1404, Air Force Information Security Program. Contractor personnel who work in Air Force controlled/restricted areas must be trained IAW AFI 31- 101, The Air Force Installation Security Program.

4.3. Antiterrorism Awareness Training. Level I – Antiterrorism (AT) Awareness Training is available to all contractor employees. Non-Common Access Card (CAC) holders can accomplish Level 1 - AT Awareness Training at https://jkodirect.jten.mil/Atlas2/page/login/Login.jsf. Additionally, contractor employees may contact the Government sponsoring agency’s Unit Antiterrorism Representative (UATR) to request Antiterrorism Awareness Training material.

4.4. Reporting Requirements. Contractor personnel shall immediately report to an appropriate Government authority any information or circumstances of which they are aware may pose a threat to the security of Department of Defense personnel, contractor personnel, resources, and classified or unclassified defense information. Contractor personnel are required to review suspicious activity reporting procedures.

Contact the Government sponsoring agency’s Unit Antiterrorism Representative (UATR) to request Suspicious Activity Reporting training material. Contact the Base Defense Operation Center (BDOC) to report actual suspicious activity at 520- 228-3200.

4.5. Incident Notification. Contractor personnel with access to a government computer shall update their AtHoc profile with current contact information to ensure receipt of incident notification. Contractor personnel without computer access should be alert for notifications from the base public address system (i.e. Giant Voice). Additional notifications can be received via the Davis Monthan AFB Facebook Page.

In the event of an incident, contractor personnel should adhere to the guidance provided in the Antiterrorism Awareness Training.

4.6. Pass and Identification Items. The contractor shall ensure that all necessary pass and identification items required for contract performance are obtained for contractor employees and non-Government owned vehicles.

4.7. Retrieving Identification Media. The contractor shall retrieve all identification media, including vehicle passes from contractor employees that depart for any reason before the contract expires (e.g.

terminated for cause, retirement, etc.) and turn them in to the issuing office. Once contractor employees are no longer employed, the contractor office shall notify the issuing office of the termination immediately.

4.8. Traffic Laws. Contractor employees shall comply with all base traffic regulations. Contractor employees are subject to random vehicle speed control checks. Contractor personnel cited for speeding on

17 AUGUST 2020 5 | P a g e the installation may suffer loss of base driving privileges, debarment from the base, or other administrative action. The use of seat belts is mandatory for all vehicle occupants. The use of cell phones is prohibited while driving on base, unless the phone is a hands-free cell phone.

4.9. Random Personnel and Vehicle Searches. Contractor personnel are subject to random personnel and vehicle searches. If contractor personnel refuse to be searched, they will be denied entry to the base, and may result in loss of base driving privileges, debarment from the base, or other administrative action.

4.10. Weapons, Firearms, and Ammunition. Contractor employees are prohibited from possessing weapons, firearms, or ammunition, on themselves or within their contractor owned vehicle or privately owned vehicle while on Davis-Monthan AFB.

4.11. For Official Use Only (FOUO). The contractor shall comply with DoD 5400.7-R, Chapter 4, DoD Freedom of Information Act (FOIA) Program requirements. This regulation sets policy and procedures for the disclosure of records to the public and for marking, handling, transmitting, and safeguarding FOUO material.

4.12. Physical Security. Contractor employees shall safeguard all Government property and controlled forms provided for contractor use. At the end of each work period, the contractor shall secure all Government facilities, equipment, and materials. The contractor shall establish and implement methods of ensuring all Government lock combinations, are not lost, misplaced, or used by unauthorized persons. The contractor shall prohibit the use of lock combinations, issued by the Government, by any persons other than the contractor’s employees. The contractor shall also prohibit and the opening of locked areas by contractor employees to permit entrance of persons other than contractor employees engaged in performance of contract work requirements in those areas.

4.13. Contractor Personnel Travel on the Installation. All contractor personnel will limit their travel on the installation only to specific areas required for performance of services, specified break and meal areas, or travel directly to and from these locations.

4.14. Controlled/Restricted Areas. The contractor shall adhere to/implement local base procedures for entry to AF controlled/restricted areas where contractor personnel work. An AF Form 2586, Unescorted Entry Authorization Certificate, must be completed and signed by the sponsoring agency’s Security Manager before a Restricted Area Badge will be issued. Contractor employees must have a favorably completed National Agency Check plus written Inquires (NACI) investigation before receiving a Restricted Area Badge. Interim access can be granted in accordance with AFI 31-501, Personnel Security Program Management.

4.15. Privacy Act. The Contractor shall ensure that its employees fully understand and comply with Title 5 of US Code, Section 552.a and DoD 5400.7-R, DoD Freedom of Information Act Program. These procedures must be followed to identify and safeguard reports and data accordingly. The contractor will ensure that Contractor employees are briefed annually on properly identifying and handling Privacy Act data/information.

4.15.1. Protection of Personally Identifiable Information. Personally Identifiable Information (PII) refers to information that can be used to distinguish or trace an individual’s identity either alone or when combined with other information that is linked or linkable to a specific individual. PII may range from common data elements such as names, addresses, dates of birth, and places of employment, to identity documents, Social Security numbers (SSN) or other government-issued identity, precise location information, medical history, and biometrics. The contractor shall protect all PII encountered in the performance of services in accordance with Department of Defense Directive 5400.11, Department of

17 AUGUST 2020 6 | P a g e

Defense Privacy Program, and DoD 5400.11-R, Department of Defense Privacy Program. If a PII breach results from the contractor's violation of the aforementioned policies, the contractor shall bear all notification costs, call-center support costs, and credit monitoring service costs for all individuals who's PII has been compromised.

4.16. Place of Performance. The contractor shall perform services on DMAFB, Tucson, AZ.

4.17. Duty Hours. 355 CES normal duty hours of operation are 7:00 a.m. to 3:30 p.m., Monday through Friday, excluding holidays. Contractor employees shall perform routine services during normal duty hours of 7:00 a.m. – 3:30 p.m., Monday through Friday, unless arrangements are made in advance in accordance with PWS paragraph 4.18., or due to mission requirements.

4.18. Contractor Performance Hours. The contractor is not restricted to perform services within the above hours of operation; however, the contractor is advised that performance outside those hours will require advance coordination with COR and affected DMAFB agencies. The contractor shall provide COR two days advance notice of their intent to perform services outside of the hours of operation above. The contractor is further advised that the 309th Aerospace Maintenance and Regeneration Group (309 AMARG) is closed weekends and federal holidays.

4.19. Fire Prevention and Safety. Hoods, ducts, and exhausts cleaning is a fire reducing function. The contractor’s performance shall be in accordance with Occupational Safety and Health Act (OSHA) Public Law 91-596, Air Force Occupational Safety and Health Standard 91-56, and National Fire Protection Association Standards/Codes. Contractor employees shall comply with DMAFB Fire Protection Program, Air Force Occupational Safety, and the Fire Prevention and Health Program. Compliance with OSHA and other applicable laws and regulations for the protection of employees is exclusively the obligation of the contractor, and the government will assume no liability or responsibility for the contractor’s compliance or noncompliance with such responsibilities.

4.20. Environmental Protection Compliance

4.20.1. Adherence to the DMAFB Contractor Environmental Guide. Adherence to environmental guide is mandatory and will help increase the contractor’s awareness of the installation’s Environmental Management System (EMS) and environmental regulatory requirements that impact DMAFB. The guide covers the significant environmental aspects and impacts that contractors often influence at DMAFB. A list of these aspects can be found in Appendix F, Environmental Management System (EMS) Most Significant Environmental Aspects Awareness Form, of the guide. Upon contract award, the contractor shall complete Appendix F and submit it to the Contracting Officer. The environmental guide will be provided by the Contracting Officer.

4.20.2. Environmental Management System (EMS) Awareness Training. The contractor shall comply with the DMAFB Contractor Environmental Guide in completing the required EMS Awareness Training prior to start of work. The training is a requirement for project managers, on-site managers/supervisors, and contractor personnel who have a direct influence on the significant aspects identified in Appendix F of the guide. Training registration and login instructions can be found in Appendix E, EMS Awareness Level Training Login and Registration Instructions, of the Contractor Environmental Guide. The contractor shall submit a completed copy of the training certificate along with Appendix F to the Contracting Officer upon contract award to document completion of training

4.20.3. Environmental Laws and Regulations. The contractor shall comply with all applicable Federal, State, and local laws, regulations, and requirements regarding environmental protection. In the event environmental laws/regulations/requirements change during the term of the contract, the contractor shall

17 AUGUST 2020 7 | P a g e comply with such law/regulation as changed. The contractor is responsible for any penalties, fines, etc.

resulting from violations. The contractor shall immediately notify the designated AMARG POC when violations occur, and cooperate fully with fire department personnel and Government investigators.

4.20.4. Environmental Permits. Contractors shall comply with all regulatory requirements to include permits if applicable. Pima County Department of Environmental Quality (PDEQ) and Arizona Department of Environmental Quality (ADEQ) require permits for asbestos removal or demolition as well as projects that require earth-moving or soil disturbance. These requirements may include storm protections. The contractor shall treat areas subject to dust producing activities with liquid palliatives which will not harm regrowth of vegetation, or other methods of dust control. The contractor shall also ensure methods to protect native plants, birds and wildlife are included in projects where required. All permit costs shall be considered as having been included as a factor in the contractor's bid price.

4.20.5. Hazardous Materials/Waste. The contractor shall be responsible for the proper management of both hazardous and non-hazardous waste. The contractor shall segregate hazardous or regulated materials and non-hazardous or non-regulated materials and handle, transport, store, and dispose of those materials, in accordance with the Resource Conservation and Recovery Act, all applicable federal, state, and local statutes and regulations, and in accordance with Appendix C, Hazardous, PCB, and Universal Waste:

Proper Management and Disposal, of the Contractor Environmental Guide. The contractor shall coordinate all hazardous shipments with the 355 Civil Engineer Squadron Hazardous Waste Program Manager (355 CES/CEIE) at 228-4840.

4.20.6. Hazardous Material (HAZMAT) Handling. The contractor shall have approval from Hazardous Waste Program Manager (355 CES/CEIE) at 228-4840, in accordance with the Contractor Environmental Guide, prior to handling, using, and storing any chemicals, solvents, lubricants, and other products that require Safety Data Sheet (SDS) or Material Safety Data Sheet (MSDS) on the installation. The contractor shall plan, fill out, and submit a HAZMAT worksheet to the COR prior to bringing HAZMAT on the base

- see Appendix A, Guidance For Submission Of Safety Data Sheets For Hazardous Material (HAZMAT) and Reporting of Hazmat Usage, and Attachment(s) A-1 to A-3 of the Contractor Environmental Guide for details. The contractor shall maintain one copy of the MSDS or SDS for each HAZMAT line item used within the work center.

4.20.7. Prohibited Substances/Chemicals. The contractor shall not use products that are, or contain Extremely Hazardous Substances (EHS), Ozone Depleting Substances (ODS), and/or Persistent Bio-accumulative and Toxic (PBT) chemicals. Any HAZMAT containing one of these banned substances will not be allowed on base. Contact the DMAFB Environmental Office (355 CES/CEIE) at 228-7201 if you have any questions on materials.

4.20.8. Hazardous Materials/Waste Spills. The contractor shall take every reasonable precaution to prevent spills of HAZMAT, and immediately report any HAZMAT spills to the designated 309 AMARG POC and base fire department by calling 228-3333, in accordance with Appendix J, HAZMAT Incident Response Procedures, of the DMAFB Spill Prevention, Control, and Countermeasure (SPCC) Plan. The contractor shall comply with this plan when handling and storing all oils and fuels. The Government Project Manager will provide the SPCC Plan to the contractor, upon contract award. The contractor shall clean and dispose of all HAZMAT spills in accordance with local, state, and federal laws and regulations and the Contractor Environmental Guide. The contractor shall bear full financial obligation incurred from cleaning and disposing of HAZMAT spills, or release of HAZMAT within the confines of DMAFB by contractor employees.

4.20.9. Spill Containment Kits. The contractor shall ensure that all vehicles used for transport of HAZMAT on DMAFB, carry a spill containment kit capable of containing a spill, until first responders

17 AUGUST 2020 8 | P a g e arrive. The contractor shall make spill containment kits available for inspection by Government personnel, upon request.

4.21. Federal Holidays. The Federal Government observes the following holidays. (Note: If the holiday falls on a Saturday then the holiday will be observed as recognized by the Federal Government). The contractor shall not normally be required to provide routine services on holidays, or the actual day set aside for observation.

New Year’s Day Labor Day Martin Luther King’s Birthday Columbus Day President’s Day Veteran’s Day Memorial Day Thanksgiving Day Independence Day Christmas Day

4.22. Contractor Employee Appearance. Contractor employees shall present a professional, conservative, and neat appearance. Contractor personnel shall report for duty in a professional manner, in appropriate attire befitting the work environment, and have complied with socially acceptable standards of personal hygiene. While performing services, contractor employees shall be neat and clean (free of visible dirt and stains), well-groomed and appropriately dressed. The contractor employee's clothing shall fit correctly to provide a professional, modest appearance, in keeping with normally accepted commercial standards of dress for the work being performed.

4.25. Communication. Contractor employees shall maintain open, professional, and respectful communication with Government personnel (military and civilian) and other contractor employees. The COR will report valid complaints in writing to the CO for action. Valid complaints will be considered a performance failure. The contractor shall resolve all substantiated complaints immediately upon notification of the complaint. Contractor employees are required to identify themselves as a contractor at all times while on the job, (e.g. in the workplace, when attending meetings, when answering Government telephones, in e-mails, or when making phone calls on behalf of the Government).

5.0. Government Services

5.1. Emergency Services. The Government will provide security forces services (call (520) 228-4444 for emergencies only), and fire protection services (call (520) 228-3333). There is no emergency room on DMAFB, therefore contractor personnel shall call (520) 228-3333 for medical emergencies.

5.2. Refuse/Recycling Service. The Government will provide refuse and recycling services with the contractor participating in the base-recycling program, and proper waste disposal practices.

17 AUGUST 2020 9 | P a g e

Appendix A. Estimated Frequency of Services

A.1. - Cooking Exhaust Hoods

Item # Building Facility Estimated No.

of Annual Cleanings

Unit

1 189 Alert Center 2 EA

2 2050 Officers Club (Kitchen) 4 EA

3 2612 Child Care Center 1 EA

4 2614 Child Care Center 1 EA

5 3203 Bowling Center (Grill) 6 EA

6 3203 Bowling Center (Pizza) 1 EA

7 4100 Dining Facility (Serving Line) 12 EA

8 4100 Dining Facility (N. Serving Line) 2 EA

9 4100 Dining Facility (Kitchen) 4 EA

10 4838 Fire Station #1 1 EA

11 6006 School Age Program 1 EA

TOTAL SERVICES 35

A.2. Paint booths / Saw Vents

Item # Building Facility Estimated No.

of Annual Cleanings

Unit

1 4531 Auto Hobby Shop 1 EA

2 5258 Corrosion Control Booth 1 EA

3 7213 AMARG Paint Booth 1 EA

4 7391 AMARG Wood Shop Vents 2 EA

5 7431 AMARG Wood Shop Vents 2 EA

TOTAL SERVICES 7

A.3. Dryers Vents

Item # Building Facility Estimated No.

of Annual Cleanings

Unit

1 189 Alert Facility 2 EA

2 1358 Security Forces Jail 2 EA

3 1713 Fire Station 2 2 EA

4 2301 Benko Gym 2 EA

5 2542 Lodging Hotel 52 EA

17 AUGUST 2020 10 | P a g e

6 2352 Temporary Lodging Facility 20 EA

7 2353 Temporary Lodging Facility 20 EA

8 2354 Temporary Lodging Facility 20 EA

9 2355 Temporary Lodging Facility 20 EA

10 2356 Temporary Lodging Facility 20 EA

11 2505 Heffner Gym 2 EA

12 2612 Child Development Center 2 EA

13 2614 Child Development Center 2 EA

14 3219 Dormitory 2 EA

15 3500 Dormitory 2 EA

16 3508 Dormitory 34 EA

17 3509 Dormitory 24 EA

18 3533 Dormitory 72 EA

19 3610 Dormitory 6 EA

20 3750 Dormitory 60 EA

21 4211 Dormitory 2 EA

22 4224 Dormitory 2 EA

23 4838 Fire Station #1 2 EA

TOTAL SERVICES 372

Review/Coordination:

Functional Services Manager

Quality Assurance Program Coordinator

Contracting Officer

5.0. Government Services

Dryer Vents:
Systems:
11Row1:
6006Row1:
EA35:
5Row1:
7431Row1:
EA7:
23Row1:
4838Row1:
EA372:
2020-08-17T13:12:50-0700
BERRIDGE.DAVID.A.1115781754
2020-08-18T10:03:25-0700
GONZALES.CHARLES.D.JR.1171381718
2020-08-19T10:22:33-0700
WEST.CORY.WILLIAM.1380629441

File details come from the government source that posted it. Updated .