This Performance Work Statement (PWS) details fire alarm panel replacement for three buildings (B123, B441, B584) at Offutt Air Force Base. The project requires contractors to remove existing fire alarm control panels manufactured by Monaco and Simplex and install new panels, specifically a Notifier NFS-320 for Buildings 123 and 584, and a Simplex 4007ES for Building 441. The scope includes providing all necessary labor, tools, equipment, and expertise to complete a one-for-one device swap, ensuring proper coverage, connections, and functionality.
Key requirements include comprehensive testing of new equipment, verification of full operational status, and documentation of the replacement and testing process. The contractor must adhere to industry standards, manufacturer guidelines, and local fire safety codes. Deliverables include replacement and test reports for each building. The solicitation (FA460025Q0056) is issued by the Department of the Air Force Air Combat Command, with a site visit scheduled for 24 July 2025, questions due by 30 July 2025, and offers due on 06 August 2025 at 10:00 AM CST. The government notes that funds are not currently available, and they reserve the right to cancel the solicitation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Performance Work Statement WT: 14683959; Fire Alarm Repair, B123, B441, B584
1. Objective
To replace and test the fire alarm control panel and devices in Building 123, replace and test a fire alarm panel and devices in Building 441, and replace and test the fire alarm control panel and devices for Building 584.
2. Scope of Work
The contractor shall provide all necessary labor, tools, equipment, and expertise to complete the following tasks:
Remove existing manufacture name: Monaco, model number: M1, serial number: 6210 fire alarm control panel, install and test government furnished manufacture name: Notifier, model number:
NFS-320 fire alarm control panel and all devices, control panels and any miscellaneous devices required for fully functional fire alarm system. Inclusive for a one for one swap of devices only in Building 123.
Remove existing manufacture name: Simplex, model number 4007 fire alarm control panel, install and test manufacture name: Simplex, model number: 4007ES fire alarm control panel and all devices, control panels and any miscellaneous devices required for fully functional fire alarm system. Inclusive for a one for one swap of devices only in Building 441.
Remove existing manufacture name: Monaco, model number: M1 fire alarm control panel, install and test government furnished manufacture name: Notifier, model number: NFS-320 fire alarm control panel and all devices, control panels and any miscellaneous devices required for fully functional fire alarm system. Inclusive for a one for one swap of devices only in Building 584.
3. Tasks and Requirements
3.1 CLIN 0001 – Replace Building 123 Fire Alarm Control Panel and Devices
Preparation: Receive government furnished Notifier NFS-320 fire alarm control panel from O utt AFB fire alarm shop supervisor.
Replacement: Remove faulty Monaco M1 panel and install new Notifier NFS-320 (government furnished) fire alarm control panel and devices, ensuring proper coverage, connections, and functionality.
Testing and Verification: Test new equipment to ensure the system is fully operational.
Documentation: Record the replacement and testing process and any issues encountered.
3.2 CLIN 0002 – Install Building 441 Fire Alarm Control Panel and Devices
Preparation: Ensure availability of SIMPLEX 1-each: 4007-9102 4007ES HYBRID FACP, PLATINUM; 1-each: 4007-9806 SDACT MODULE; 2-each: 2081-9275 BATTERY 18AH; 2-each: 4007-9801 ZONE-RELAY MODULE; 1-each: 4098-9714 PHOTO SENSOR; 4-each:
4098-9792 SENSOR BASE; 2-each: 4099-9004 STATION-LED, SA ADDR; 3-each: 4098-9733
HEAT SENSOR.
Replacement: Remove faulty Simplex 4007 panel and install new Simplex 4007 fire alarm control panel and devices, ensuring proper coverage, connections, and functionality.
Testing and Verification: Test new equipment to ensure the system is fully operational.
Documentation: Record the install and testing process and any issues encountered.
3.3 CLIN 0003 – Replace Building 584 Fire Alarm Control Panel and Devices
Preparation: Receive government furnished Notifier NFS-320 fire alarm control panel from O utt AFB fire alarm shop supervisor.
Replacement: Remove faulty Monaco M1 panel and install new Notifier NFS-320 (government furnished) fire alarm control panel and devices, ensuring proper coverage, connections, and functionality.
Testing and Verification: Test new equipment to ensure the system is fully operational.
Documentation: Record the replacement and testing process and any issues encountered.
4. Deliverables
Replacement report and test results for Building 123.
Installation report and test results for Building 441.
Replacement report and test results for Building 584.
5. Performance Standards
All work must be performed in accordance with industry standards and manufacturer guidelines.
The fire alarm systems must be fully operational and free of faults upon completion of the work.
6. Safety and Compliance
Adhere to all relevant safety regulations and protocols.
Ensure compliance with local fire safety codes and standards.
Reference Attached approved O utt Fire Alarm Panels manufacturers.
Building 123 panel:
Building 441 panel:
Building 584 panel: