PWS Appendix A - Raised Access Floor Plan.pdf
PDF 780 KB Posted
- Attached to
- OGD raised floor Federal contract opportunity
- Solicitation number
- HC102824R0075
- Issued by
- Defense Information Systems Agency
About this file
This document appears to be a set of architectural drawings, specifically a Performance Work Statement (PWS) Appendix A containing a raised access floor plan for the DISA Data Center in Ogden, Utah. The drawings provide details on the existing conditions and requirements for installing a new raised access floor system, including phasing the work to minimize disruption to the existing temperature-controlled computer rooms. The drawings specify the floor rating, cut-outs and grommets for IT and power cabling, and requirements for protecting existing equipment and spaces. This package is related to a federal contract opportunity, Solicitation Number HC102824R0075, for an Ogden raised floor upgrade project. The solicitation is being issued by the Defense Information Systems Agency (DISA), a combat support agency, and includes a requirement for a pre-proposal site visit on September 4, 2024.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Pre Bid Questions HC102824R0075.docx | DOCX document | |
| updated Pre-Proposal Site Visit Request Instructions (OGD RF and SRG).doc | DOC document | |
| HC102824R0075 solicitation amend 1.pdf | ||
| Pre-Proposal Site Visit Request Instructions (OGD RF and SRG).doc | DOC document | |
| PWS Appendix C - DISA NDA.docx | DOCX document | |
| HC102824R0075 solicitation.pdf | ||
| OGD pricing sheet.xlsx | XLSX spreadsheet | |
| Pre-Proposal Site Visit Request Instructions (OGD RF and SRG).doc | DOC document | |
| PWS Appendix B - 09 69 13 - Rigid Grid Access Flooring.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OGDEN COVER SHEET
DEFENSE INFORMATION SYSTEMS AGENCY
DATA CENTER -OGDEN
FY24 - RF UPGRADE
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
C O
N C
EP
T
D R
AW
IN
G S
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A C
EN
TE
R O
G D
EN
H
IL
L
AI
R
F O
R C
E
BA
SE
R
F U
PG
R
AD
E
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
FY2
2 RE
PAIR
DO
CK &
INST
ALL
DO
OR
OPE
RAT
OR
S
/0
6/
AA
3/
/2
O G
D _G
-0
G-001
AR
C
H
IT
EC
TU
R
AL
O G
D
EN
C O
VE
R
S H
EE
T
/2
2/
Sheet List Table Sheet Number Sheet Title
GENERAL
G-001 OGDEN COVER SHEET
G-100 LEGEND SHEET
ARCHITECTURAL
AD-101 COMPOSITE FLOOR- DEMO WORK
A-101 RAISED ACCESS FLOOR PLAN
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FAIRFIELD
AutoCAD SHX Text
CEDAR FORT
AutoCAD SHX Text
STOCKTON
AutoCAD SHX Text
DUGWAY
AutoCAD SHX Text
OPHIR
AutoCAD SHX Text
LEHI
AutoCAD SHX Text
TOOELE
AutoCAD SHX Text
GRANTSVILLE
AutoCAD SHX Text
CITY
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
SALT
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
RUSH
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
SALT
AutoCAD SHX Text
GREAT
AutoCAD SHX Text
OGDEN
AutoCAD SHX Text
PROVO
AutoCAD SHX Text
HILL AIR
AutoCAD SHX Text
FORCE BASE
AutoCAD SHX Text
SALT LAKE
AutoCAD SHX Text
INTERNAT'L
AutoCAD SHX Text
AIRPORT
AutoCAD SHX Text
TOOELE
AutoCAD SHX Text
ARMY
AutoCAD SHX Text
DEPOT
AutoCAD SHX Text
AREA
AutoCAD SHX Text
SOUTH
AutoCAD SHX Text
TAD
AutoCAD SHX Text
GROUNDS
AutoCAD SHX Text
DUGWAY
AutoCAD SHX Text
PROVING
AutoCAD SHX Text
UTTR
AutoCAD SHX Text
HILL AIR FORCE
AutoCAD SHX Text
PROXIMITY MAP
AutoCAD SHX Text
LITTLE
AutoCAD SHX Text
MOUNTAIN
AutoCAD SHX Text
ANNEX
AutoCAD SHX Text %%u VICINITY MAP %%U
LEGEND SHEET
1. DURING THE ENTIRE DURATION Of THIS CONTRACT, ALL ADJACENT OCCUPIED SPACES HAVE ONGOING (DAY-TO-DAY) MISSION ESSENTIAL WORK. THIS FACILITY WILL REMAIN FULLY FUNCTIONAL AND OCCUPIED AT ALL TIMES. THE CONTRACTOR SHALL EXERCISE CARE TO REDUCE NOISE AND ENSURE
SAFE INSTALLATION ACTIVITIES WHILE MINIMIZING DISTURBANCES. THE CONTRACTOR SHALL
COORDINATE THE WORK OF ALL ACTIVITIES WHEREBY BOTH THE GOVERNMENT AND THE CONTRACTOR CAN CONTINUE OPERATIONS WITH THE LEAST POSSIBLE INTERFERENCE AND INCONVENIENCE. THE
CONTRACTOR SHALL CONDUCT ALL WORK SUCH THAT MEANS OF INGRESS AND EGRESS, FIRE
RESPONSE ROUTES, ETC., ARE MAINTAINED AT ALL TIMES.
2. ALL INSTALLATION DEBRIS, TRASH, ETC. SHALL BE MAINTAINED IN CONTRACTOR PROVIDED DUMPSTER, IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL ENVIRONMENTAL LAWS AND REGULATIONS.
3. ALL AREAS SHALL BE CLEANED AT A MINIMUM DAILY AND AS REQUIRED TO MAINTAIN A PROFESSIONAL APPEARANCE AT All TIMES. ALL EXISTING BUILDING INTERIORS AFFECTED BY INSTALLATION SHALL BE MAINTAINED AND FULLY PROTECTED BY THE CONTRACTOR UNTIL COMPLETION OF WORK FOR THIS
PROJECT.
4. CONTRACTOR SHALL INSTALL NEW RAISED ACCESS FLOOR IN ACCORDANCE WITH THE "PERFORMANCE WORK STATEMENT", (PWS). THE NEW FLOOR INSTALLATION SHALL BE PHASED WITH THE OLD FLOOR
REMOVAL IN INCREMENTAL SECTIONS. WORK IN COMPUTER ROOMS SHALL NOT DISRUPT THE
TEMPERATURE CONTROLLED CLIMATE IN THE COMPUTER ROOM. THE EXISTING FLOOR IS FLOATING, FLOOR PANEL REMOVAL SHALL BE LIMITED TO REDUCE RISK OF THE EXISTING FLOOR SHIFTING.
EXISTING CRAHs, PDUs, AND MISSION IT RACKS SHALL REMAIN FULLY FUNCTIONAL..
5. SEE PWS AND ITS APPENDICES FOR INFORMATION CONCERNING "RIGID GRID ACCESS FLOORING" DETAILING, INSTALLATION AND SPECIFICATIONS. PROVIDE INSTALLATION PLANS PER REQUIREMENTS OF
THE PWS.
6. THE CONTRACTOR SHALL PROTECT ALL EXISTING FLOORS, EQUIPMENT AND/OR NEARBY SPACES OR AREAS TO REMAIN. IF DAMAGED DURING WORK PERFORMED IN ACCORDANCE WITH THIS PROJECT, CONTRACTOR MUST REPAIR OR REPLACE TO ITS ORIGINAL CONDITION AT CONTRACTOR EXPENSE.
7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR FURNISHING, AND INSTALLING SIGNS, PROTECTION BARRIERS, ETC., TO WARN OCCUPANTS OF HAZARDOUS AREAS AT THE JOB SITE AND
STORAGE AREAS FOR THE DURATION OF THE CONTRACT.
8. THE DRAWINGS INDICATE EXISTING CONDITIONS BASED ON INFORMATION OBTAINED FROM THE AVAILABLE RECORD DRAWINGS AND FIELD SURVEYS. EXISTING CONDITIONS NOT RELATED TO THE WORK OF THIS PROJECT MAY NOT BE SHOWN. EXISTING CONDITIONS PROVIDED ARE NOT GUARANTEED
TO BE COMPLETE OR CORRECT. PRIOR TO THE START OF THE DESIGN/INSTALLATION, THE
CONTRACTOR/DESIGNER SHALL FIELD VERIFY THE LOCATION, SIZES, CLEARANCES, BUILDING
ELEMENTS ETC. RELATED TO THE WORK. THE DRAWINGS PROVIDED ARE DIAGRAMMATIC AND SHALL BE
CONFIRMED BY THE CONTRACTOR/DESIGNER.
GENERAL NOTES
RAISED FLOOR EQUIPMENT LEGEND:
CRAH UNIT (COMPUTER ROOM
AIR HANDLER)
PDU (POWER DISTRIBUTION UNIT)
SERVER RACK
HUMIDIFIER
CABINET
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
C O
N C
EP
T
D R
AW
IN
G S
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A C
EN
TE
R O
G D
EN
H
IL
L
AI
R
F O
R C
E
BA
SE
R
F U
PG
R
AD
E
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
FY2
2 RE
PAIR
DO
CK &
INST
ALL
DO
OR
OPE
RAT
OR
S
/0
6/
AA
3/
/2
O G
D -G
-1
G-100
AR
C
H
IT
EC
TU
R
AL
LE
G
EN
D
S H
EE
T
M
PL
/2
2/
LOBBY
OFFICE
CORRIDOR
CORRIDOR
201B
CORRIDOR
OFFICE
OFFICE
OFFICE
TELCOM/
COMMS
OFFICE
175B
OFFICE
175A
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
VCC
210A
VCC
212A
CORRIDOR
CORRIDOR
216A
COMPARTMENTALIZED COMPUTER SPACE
TRM-768
EF_9_165
CRAH_1-DC-32
40 TONS
"CRAC 32"
C R
AH
_1
-C D
-3
T
O N
S "C
R
AC
1"
PDU_1-B-24
225 KVA
"PDU 701B"
PDU_1-B-25
225 KVA
"PDU 703B"
CRAH_1-DC-22
CRAH_1-DC-36
30 TONS
CRAH_1-DC-38
30 TONS
"CRAC-38"
CRAH_1-CD-37
30 TONS
"CRAC-37"
PDU 801-B
125 KVA
"PDU_1-B-22 "
PDU 801-A
125 KVA
"PDU_1-A-22 "
PDU 802-B
125 KVA
"PDU_1-B-23 "
PDU 802-A
125 KVA
"PDU_1-A-23"
INLET
HOOD
V_1-A-29
V_1-A-15
CORRIDOR
KEY PLAN 1st FLOOR
SCALE: NONE
PLAN
REFERENCE
NORTH
N
COMPOSITE FLOOR- DEMO WORK
SCALE : 1/8" = 1'-0"
AA
3/
/2
O G
D -A
D -1
AD-101
AR
C
H
IT
EC
TU
R
AL
C O
M
PO
SI
TE
F
LO
O R
- D
EM
O W
O R
K
M
PL
/2
2/
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
C O
N C
EP
T
D R
AW
IN
G S
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A C
EN
TE
R O
G D
EN
H
IL
L
AI
R
F O
R C
E
BA
SE
R
F U
PG
R
AD
E
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
FY2
2 RE
PAIR
DO
CK &
INST
ALL
DO
OR
OPE
RAT
OR
S
/0
6/
KEYED NOTES:
1. CONTRACTOR SHALL REMOVE THE OLD ACCESS FLOOR SYSTEM IN
ACCORDANCE WITH THE PWS. THE NEW RAISED FLOOR INSTALLATION SHALL
BE PHASED WITH THE OLD FLOOR REMOVAL IN INCREMENTAL SECTIONS.
WORK IN COMPUTER ROOMS SHALL NOT DISRUPT THE TEMPERATURE
CONTROLLED CLIMATE IN THE ROOMS EXISTING CRAHs, PDUs, AND
MISSION IT RACKS SHALL REMAIN FULLY FUNCTIONAL. EXISTING FLOOR IS A
FLOATING FLOOR, FLOOR PANEL REMOVAL SHALL BE LIMITED TO PREVENT
FLOOR FROM SHIFTING. WORK AT ENTRY POINTS OF COMPUTER ROOMS
AND CORRIDORS SHALL BE PERFORMED TO ALLOW SITE PERSONNEL
ACCESS INTO ADJACENT SPACES.
2. REMOVE EXISTING WALL BASE ALONG EXISTING RAISED ACCESS FLOOR
PANELS WHERE FLOOR PANELS AT WALL ARE REMOVED.
TAKE CARE TO MINIMIZE DAMAGE TO WALL WHEN REMOVING WALL BASE.
3. REMOVE EXISTING FLOOR PANELS, STRINGERS, AND PEDESTALS. UPGRADE
FLOOR TILE TO 2000 LB. RATED TILES IN ACCORDANCE WITH THE PWS.
4. WHERE FLOOR PANELS GO BELOW PARTITION WALLS, DO NOT REMOVE THE
FLOOR PANEL UNDER THE PARTITION WALL.
5. REMOVE FLOOR PANEL UNDER PARTITION WALL BETWEEN 216A AND 217
ONLY. REMAINING TILES IN ROOM 217 ARE NOT REMOVED.
0 4' 8' 16'
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
1 2 3
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
1 2 3 4
1 2 3
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
OFFICE
CORRIDOR
OFFICE
OFFICE
OFFICE
TELCOM/
COMMS
OFFICE
175B
OFFICE
175A
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
VCC
210A
VCC
212A
CORRIDOR
CORRIDOR
216A
COMPARTMENTALIZED COMPUTER SPACE
CRAH_1-DC-32
40 TONS
"CRAC 32"
C R
AH
_1
-C D
-3
T
O N
S "C
R
AC
1"
PDU_1-B-24
225 KVA
"PDU 701B"
PDU_1-B-25
225 KVA
"PDU 703B"
CRAH_1-DC-36
30 TONS
CRAH_1-DC-38
30 TONS
"CRAC-38"
CRAH_1-CD-37
30 TONS
"CRAC-37"
PDU 801-B
125 KVA
"PDU_1-B-22 "
PDU 801-A
125 KVA
"PDU_1-A-22 "
PDU 802-B
125 KVA
"PDU_1-B-23 "
PDU 802-A
125 KVA
"PDU_1-A-23"
EDP_1-D-34
INLET
HOOD
V_1-A-29
V_1-A-15
CORRIDOR
KEY PLAN 1st FLOOR
SCALE: NONE
PLAN
REFERENCE
NORTH
N
RAISED ACCESS FLOOR PLAN
SCALE : 1/8" = 1'-0"
AA
3/
/2
O G
D -A
D -1
A-101
AR
C
H
IT
EC
TU
R
AL
R
AI
SE
D
A C
C
ES
S
FL
O O
R P
LA
N
M
PL
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
C O
N C
EP
T
D R
AW
IN
G S
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A C
EN
TE
R O
G D
EN
H
IL
L
AI
R
F O
R C
E
BA
SE
R
F U
PG
R
AD
E
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
FY2
2 RE
PAIR
DO
CK &
INST
ALL
DO
OR
OPE
RAT
OR
S
/0
6/
GENERAL NOTES:
1. NEW ACCESS FLOOR TILES SHALL BE INSTALLED FLUSH WITH EXISTING
ADJACENT FINISHED FLOOR AND FLOOR PANELS WHICH ARE BENEATH PARTITION WALLS
(ROOM 216 AND CORRIDOR 210 ONLY). PROVIDE DETAILS ON CONTRACTOR-GENERATED
INSTALLATION PLANS.
2. SEE "PERFORMANCE WORK STATEMENT" (PWS) AND ITS APPENDICES FOR
INFORMATION CONCERNING RIGID GRID ACCESS FLOORING.
3. PROVIDE CUT-OUTS AND GROMMETS FOR I.T. AND POWER CABLING AT I.T.
RACKS AND POWER DISTRIBUTION UNITS. SEE PWS AND COORDINATE
LOCATION WITH SITE POC.
4. WHERE CUT-OUTS ARE REQUIRED IN FLOOR PANELS TO ALLOW FOR I.T. AND POWER
CABLING OR OTHER PENETRATIONS:
- PROVIDE/INSTALL FLUSH MOUNTED GROMMETS WITH BRUSHES
(TO SEAL OFF AIR FLOW) TO COVER CUTOUTS IN ACCESS FLOOR PANELS. GROMMETS
SHALL BE EITHER CUT IN HALF, OR BE 2-PIECE NESTING UNITS - TO ALLOW FOR EASY
REMOVAL OF FLOOR PANELS, WHILE ALLOWING CABLING TO REMAIN IN PLACE.
GROMMETS SHALL BE EITHER KOLDLOK 1010 (CUT IN HALF) OR KOLDLOK 3030 (2-PIECE)
OR APPROVED EQUAL.
- FLOOR PANEL CUT-OUTS FOR EQUIPMENT THAT CANNOT BE DISCONNECTED SHALL BE
ON THE EDGES OF PANELS. THIS WILL ALLOW FLOOR PANELS TO BE REMOVED AND
REPLACED, WHILE ALLOWING CABLING TO REMAIN IN PLACE.
KEYED NOTES:
1. CONTRACTOR SHALL INSTALL NEW RAISED ACCESS FLOOR PANELS, STRINGER,
AND PEDESTALS RATED FOR 2000 LBS IN ACCORDANCE
WITH THE PWS. THE NEW RAISED ACCESS FLOOR INSTALLATION SHALL BE
PHASED WITH THE OLD FLOOR REMOVAL IN INCREMENTAL SECTIONS.
WORK IN COMPUTER ROOMS SHALL NOT DISRUPT THE TEMPERATURE
CONTROLLED CLIMATE IN THE ROOMS, EXISTING CRAHs, PDUs, AND MISSION
I.T. RACKS SHALL REMAIN FULLY FUNCTIONAL.
2. THE CONTRACTOR SHALL REPAIR DAMAGE CAUSED DURING THE PERFORMANCE
OF THIS PROJECT. CLEAN THE STRUCTURAL CONCRETE FLOOR DURING
REPLACEMENT OF ACCESS FLOOR SYSTEM AS REQUIRED BY THE PWS.
3. INSTALL NEW WALL BASE WHERE PERIMETER FLOOR PANELS ARE REPLACED.
4. ENSURE EXISTING FLOOR PANELS WHICH RUN UNDER PARTITION WALLS AND
NOT REPLACED REMAIN FULLY SUPPORTED.
1 2 3
1 2 3
1 2 3 4
0 4' 8' 16'
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
1 2 3 4
NOT I
N S
COPE
NOT I
N S
COPE
1 2 3 4
NOT I
N S
COPE
NOT I
N S
COPE
NOT I
N S
COPE
1 2 3
| G-001 |
| Sheets and Views |
| OGD_G-001-G-001 |
| G-100 |
| Sheets and Views |
| OGD-G-100-G-100 |
| AD-101 |
| Sheets and Views |
| OGD-AD-102-AD-101 |
| A-101 |
| Sheets and Views |
| OGD-AD-102-A-101 |
File details come from the government source that posted it. Updated .