PW1615-25 - Addendum 1.pdf
PDF 1 MB Posted
- Solicitation number
- S-C25102-00012841
- Issued by
- Marion County, Oregon
About this file
I apologize, but the file content you've referenced is not actually present in the provided text. While the context mentions an Addendum 1 for a project related to Salmon Falls Park Habitat Enhancement in Oregon, the specific details of the Addendum are not included. Without the actual file content, I cannot provide a comprehensive summary. To accurately summarize the document, I would need to see the full text of the Addendum 1 file (PW1615-25 - Addendum 1.pdf).
The only confirmed details are from the state and local contract opportunity description, which indicates this is a habitat enhancement project for Salmon Falls County Park in Oregon, aimed at reestablishing ecological and hydrological functions after damage from the 2020 Beachie Creek fire and subsequent logging/clean-up efforts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| OregonBuys - PW1615-25.pdf | ||
| Notice of Intent to Award Letter - PW1615-25~1.pdf | ||
| Q and A Presentation.pdf | ||
| BidDetail.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PW1615-25 - ITB - Construction of Salmon Falls Park Habitat Enhancement Page 1 of 3
ADDENDUM #1
TO THE
INVITATION TO BID
PW1615-25 - ITB - CONSTRUCTION OF SALMON FALLS PARK HABITAT
ENHANCEMENT
ISSUED ON 2/17/2025 9:00:00 AM
The following information in this addendum, hereby become part of the Invitation To Bid. It is essential that all prospective Offerors note the content of this Addendum.
A. Exhibit 7 – Special Provisions: Update the following information
i. Remove existing Professional of Record Certification and Replace with the attached.
ii. SECTION 01030 – SEEDING
Comply with Section 01030 of the Standard Specifications modified as follows:
01030.13(f) Types of Seed Mixes - Add the following to the end of this subsection:
Provide the following seed mix formulas:
Botanical Name PLS Specified Rate Triticum aestivum x Elytigia elongata 35-40 (lb/acre) (Common Name) (Regreen) (or as recommended by supplier)
01030.15 Mulch – Delete “or plant seeds” from first sentence.
Add the following paragraph and bullets to the end of this subsection:
Furnish mulch slurry for seeding according to the following:
• Standard hydromulch (per 01030.48(3))
• Tackifier (per 01030.16)
• Ecobiotics Plus (per 01030.47)
• Regreen (per specified rate)
iii. SECTION 00280 – EROSION AND SEDIMENT CONTROL
00280.00 Scope - Replace “1200-CA” with “1200-CN” in the paragraph that beings with “This Work…”.
Delete the paragraph that begins “When contaminants, pollutants or hazardous materials…”.
Add the following paragraph to the end of this subsection:
Marion County’s NPDES 1200-CAN permit is applicable to the Project.
00280.04 Erosion and Sediment Control Plan on Agency Controlled Lands - Replace the bullet that begins “Information required under 1200-CA…” with the following bullet:
Information required under 1200-CN permit, if applicable.
iv. SECTION 00290 – ENVIRONMENTAL PROTECTION
00290.30(a)(8) Turbidity Monitoring - In addition to the requirements of 00280.62(c) to monitor the receiving stream to identify water quality issues, during Work in waters of the State or U.S., implement best management practices (BMPs) to minimize turbidity and monitor turbidity according to the following:
• Every four hours, make observations at an upcurrent location outside the influence of the Project, and at a downcurrent location representative of turbidity caused by the Project.
• Document all turbidity monitoring observations including date, time, and location on form 734-2755, “Turbidity Monitoring Report” or another form approved by the Engineer. Submit reports to the Engineer weekly while working aroundin waters of the State or U.S. and keep copies of the reports at the Project Site.
• A visible downcurrent turbidity plume emanating from the work area requires a presumption that project-caused turbidity is more than 10% above the upcurrent background level and is therefore in violation of DEQ’s turbidity water quality standard (OAR 340-041-0036), unless turbidity meter analyses of samples taken from an upcurrent location and from a location within the visible plume show that the actual turbidity increase is no more than 10% above the upcurrent background level.
• If observations indicate that the Project has increased turbidity to more than 10% above the upcurrent background level, modify work procedures and repair or upgrade BMPs.
If turbidity is still more than 10% above the upcurrent background level at the next four-hour observation, stop turbidity-causing Work and repair or upgrade BMPs.
Resume such Work when downcurrent turbidity returns to no more than 10% above the upcurrent background level.
v. SECTION 00305 – CONSTRUCTION SURVEY WORK
Comply with Section 00305 of the Standard Specifications modified as follows:
00305.00 Scope – Add the following paragraph at the end of this section:
Project site is located outside of cellular service. Connecting to a network is not available.
00305.90 Payment – Replace this subsection except for title and number with the following:
No separate or additional payment will be made for work performed under this section.
B. Civil Engineering Construction Plans: Remove and Replace with the attached.
Remove:
C000 Civil Engineering Construction Plans
C050 1200-CN EROSION AND SEDIMENT CONTROL PLAN
Replace with:
C000 Civil Engineering Construction Plans
C050 1200-CA EROSION AND SEDIMENT CONTROL PLAN
EXHIBIT 7
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
S A
L M
O N
F A
L L
S P
A R
K M
A R
IO
N
C O
U N
T Y
P A
R K
S L
Y O
N S
O R
E G
O N
C O
V E
R S
H E
E T
W
IT
H S
IT
E
A N
D V
IC
IN
IT
Y
M A
P S
C000
SALMON FALLS PARK HABITAT ENHANCEMENT
CIVIL ENGINEERING CONSTRUCTION PLANS
VICINITY MAP
SITE MAP
PROJECT RECORD DRAWING
CIVIL ENGINEERING/
SURVEYING/LAND USE
PLANNING/LANDSCAPE
ARCHITECTURE FIRM OWNER
PROJECT LOCATION VERTICAL DATUM
ATTENTION EXCAVATORS
PROJECT ADDRESS
Know what's below.
before you dig.Call
R
LEGEND
SHEET INDEX
DIGITALLY SIGNED
1200-CA EROSION AND SEDIMENT CONTROL PLAN
SITE MAP
VICINITY MAP
ATTENTION EXCAVATORS:
RATIONALE STATEMENT
SALMON FALLS PARK HABITAT ENHANCEMENT
Know what's below.
before you dig.Call
R
INSPECTION FREQUENCY:
PROJECT LOCATION
PROPERTY DESCRIPTION
CIVIL ENGINEERING / SURVEY FIRM
DEVELOPER/APPLICANT
NARRATIVE DESCRIPTIONS
CONTRACTOR
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
S A
L M
O N
F A
L L
S P
A R
K M
A R
IO
N
C O
U N
T Y
P A
R K
S L
Y O
N S
O R
E G
O N
E R
O S
IO
N
A N
D S
E D
IM
E
N T
C O
N T
R O
L P
L A
N
E S
C P
C
O V
E R
S H
E E
T
C050
SHEET INDEX
CONTROL PLAN DRAWING NOTES:
STANDARD EROSION AND SEDIMENT
LOCAL AGENCY-SPECIFIC EROSION CONTROL NOTES:
DIGITALLY SIGNED
File details come from the government source that posted it. Updated .