PVCC B2260-072 M22PV116 Addendum 03 2024-02-06.pdf
PDF 153 KB Posted
- Attached to
- Replace Underground Water Line at Piedmont Virginia Community College, PC#260-B2270-072 (M22PV116)
- Solicitation number
- 56301
- Issued by
- Albemarle County, Charlottesville City, Virginia
About this file
This document is an Addendum to the contract documents for the Replace Underground Water Line project at Piedmont Virginia Community College, Project Code # 260-B2260-072 (M22PV116), located in Charlottesville, Virginia, which serves Albemarle County and the City of Charlottesville. The Addendum clarifies that if trenchless or directional boring is used instead of the specified PVC SDR-21 piping, the pipe specification shall be Polyethylene (PE) Pipe SDR-9 (250 PSIG) RATED, Copper Tube Size (CTS) made from PE4710 resin with compression joints and molded fittings per AWWA C901. The project generally involves the replacement of approximately 1,600 sq. ft. of water line. Sealed bids are due by 2:00 P.M. on Tuesday, February 13, 2024, and will be opened and read aloud the following day. A pre-bid conference was held on January 18, 2024, which was optional but highly recommended for bidders.
The bid documents do not provide information on pricing terms, set asides, incumbents, funding requirements and sources, or other salient financial details. The contract opportunity is being administered by the Virginia Community College System on behalf of Piedmont Virginia Community College.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PVCC REPLACE UNDERGROUND WATERLINE PAGE 1 OF 1
PROJECT NO. 22100 (PC#260-B2260-072 M22PV116) ADDENDUM NO. 3
PVCC REPLACE UNDERGROUND WATERLINE
PC# 260-B2260-073 (M22PV116)
Project No. 22100
ADDENDUM NO. 3
February 6, 2024
This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated January 8, 2024.
Acknowledge receipt of this Addendum (1 page) in the space provided on the BID FORM.
Failure to do so may subject the Bidder to disqualification.
The following items clarify, modify, change, delete from or add to the Contract Documents.
When any paragraph, subparagraph, or sub-subparagraph thereof is modified or deleted by this Addendum, the unaltered provisions of that paragraph, subparagraph or sub-subparagraph shall remain in effect.
CLARIFICATIONS / GENERAL:
1. Drawing C102 specifies PVC SDR-21 piping for trenched installation. Should trenchless or directional boring as allowed by option in Addendum No. 2 be chosen the pipe specification shall be Polyethylene (PE) Pipe SDR-9 (250 PSIG) RATED, Copper Tube Size (CTS) made from PE4710 resin with compression joints and molded fittings per
AWWA C901.
SPECIFICATIONS: NONE
DRAWINGS: NONE
END OF ADDENDUM
2/6/24
File details come from the government source that posted it. Updated .